EXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW

Size: px
Start display at page:

Download "EXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW"

Transcription

1 -4 /4" 8" 4'-9 /" 6'-4" '-8" DEPRESS TO ACCOMODATE DOOR ABOVE DOWEL NEW FOOTING TO WITH 3-5M DOWELS, DOWEL THE NEW S TO THE S WITH 4" O.C. VERTICALLY, PROVIDE -5M BARS 6" LONG IN THE FOOTING 4'-9" UNEXCAVATED FOUNDATION GARAGE/HOUSE TRANSITION TO BE SITE VERIFIED FOR HEIGHT BASED ON FLOOR ELEVATION 3'-5" -x4 LEDGER w/ /" DIA. LAG 6" O.C. 4" INTO SOLID CONCRETE/MASONRY UNEXCAVATED BASEMENT (TO REMAIN) 4' /" " o.c. W/ BRIDGING '-6" DEPRESS TO ACCOMODATE OVERHEAD GARAGE DOOR ABOVE 6'-0 /4" 0'-4" 9 /" '-6 3/4" '- /4" '-6" 8" '-0" 5' - 5" " o.c. W/ BRIDGING 3' - 6" x0 P.T. 6" O.C. 3-x8 P.T. BEAM (FLUSH) '-5" '-" 4'-0" 3'-6" DOWEL NEW FOOTING TO WITH 3-5M DOWELS, DOWEL THE NEW S TO THE S WITH 4" O.C. VERTICALLY, PROVIDE - 5M BARS IN FOOTINGS EXTENDING 4" AROUND THE CORNER -0 /8" '-5" 5'-" '-5" 7'- 3/4" 34'-8 3/4" 6'-9" 7"x7" POURED CONCRETE PIER w/ 34" x 34" x 8" thk. PAD FOOTING TO SUPPORT MASONRY/STRUCTURAL COLUMN ABOVE (c/w BEAM POCKETS IN ARE) (TYPICAL) NOTES:. ALL EXTERIOR S TAKEN TO THE FACE OF. ALL INTERIOR DIMENSIONS ARE TAKEN TO THE INTERIOR FACE OF 3. ALL FOOTINGS TO EXTEND TO UNDISTURBED SOIL (4'-0" BELOW FINISHED GRADE) ( (TYP.) 4. FRAMING CONTRACTOR TO VERIFY THAT ALL POINT LOADS FROM ABOVE ARE CARRIED TO FOUNDATIONS / FOOTINGS (TYP.) FOUNDATION PLAN /4" = '-0" TYPICAL FOUNDATION W EXTERIOR WITH STONE VENEER W EXTERIOR WITH VINYL SIDING INTERIOR x6 PARTITION DESCRIPTION 8" POURED CONCRETE (POURED ON 0"X6" POURED CONC. FOOTING ON UNDISTURBED SOIL) DESCRIPTION 3.5" STONE VENEER c/w MASONRY TIES (4" HORIZ. & 6" VERT.) " AIR SPACE 7/6" O.S.B. EXTERIOR GRADE SHEATHING " x 6" WOOD 6" o/c R-4 BATT INSULATION /" GYPSUM BOARD DESCRIPTION VERTICAL BOARD AND BATTEN VINYL SIDING " x 6" WOOD 6" o/c 7/6" O.S.B. EXTERIOR GRADE SHEATHING R-4 BATT INSULATION /" GYPSUM BOARD DESCRIPTION /" GYPSUM BOARD (TAPED AND SEALED ON GARAGE SIDE) TYVEK BUILDING PAPER (COLD SIDE R-4 BATT INSULATION " x 6" WOOD STUDS@ 6" o/c (WARM SIDE) /" GYPSUM BOARD Wg DENOTES S IN GARAGES TO BE FRAMED WITH x4 STUDS Wg DENOTES S IN GARAGES TO BE FRAMED WITH x4 STUDS FOUNDATION PLAN EXW EXTERIOR DESCRIPTION EX. BRICK VENEER EX. SHEATHING EX. x4 WOOD STUDS EX. FINISH EXW INTERIOR DESCRIPTION EX. x4 WOOD STUDS DESCRIPTION EX. WATERPROOFING EX. 8" CONCRETE EX. x4 WOOD STUDS 03/30/06 STRUCTURAL STAMP PROVIDED FOR LEDGER DESIGN AND FOUNDATION CONNECTION DESIGN TO RESIDENCE MARCH 4 06 A

2 4'- /" EX. CARPORT TO BE CONVERTED TO LIVING SPACE 43'-9" RESIDENCE TO REMAIN 7'-0" x 9'-0" HINGED 4" -0" BARN DOOR 5 /" ACCESS TO ATTIC 4'- /" STORAGE ABOVE Wg FOLD DOWN SHIP LADDER TO ACCESS STORAGE LOFT ABOVE 3'-3" 3'-8" OUTLINE OF CONCRETE SLAB SHOWN DASHED AND SHADED '-" 9'-" STEP '-0 /" NEW ACCESS DOOR EXW 3'-0" x 7'-0" HINGED 3'-0" x 7'-0" HINGED BARN DOOR-x LINTEL BARN DOOR W D5 W 6" 8 /" '-3 3/4" '-7 /" 3'-7 3/4" 4" Wg WORKSHOP AREA 3'-7 3/4" -x0 LINTEL GARAGE (WITH STORAGE LOFT ABOVE) Wg -0" 33' - 5" PRE-ENG 4" O.C. 0' 0" OVERHEAD DOOR DRIVEWAY 3'- /4" -6 /4" 5'- /" 4" 7'- /" 6" MAIN FLOOR PLAN /4" = '-0" PRE-ENG ATTIC GIRDER TRUSS x0 CEILING JOIST AND x0 ROOF JOIST LADDER FRAMING BETWEEN GIRDER AND END GABLE D3 PRE-ENG LINTEL 3' - 4" W -x0 LINTEL D 4 /4" -x0 LINTEL LIVING AREA W MILLWORK CLOSET AND STORAGE UNITS w/ OPENINGS ABOVE DROP ZONE 3-x0 LINTEL WINDOW SEAT (w/ STORAGE BELOW -x0 LINTEL BOX/BAY WINDOW W W 4'- /" PIANO AREA FOYER NEW DUCTWORK TO BE RUN IN LEDGE STAIRS UP: W x6 PINE DECKING BENCH FRONT PORCH STEP '- /4" -x0 LINTEL -x0 LINTEL PRE-ENG LINTEL ARCHWAY 6" 7'-6 /" 6" 6'- /4" 0 /" D 3'-8" D6 ADDITION '-" W6 '-6" D7 -x0 LINTEL STAIRS UP: R@7-7/8" PORTION OF EX. EXT. TO BE REMOVED 3'-6" 0 /" 3'- /" DN RESIDENCE GROUND FLOOR ADDITION AREA = 435 SQUARE FEET STAIRS TO BASEMENT PROVIDE OPENINGS BETWEEN BEARING EXW DINING AREA '-5" '-0" 6'-5 /" FRONT PORCH KITCHEN NOOK CONSTRUCTION TO CONFORM TO O.B.C SB- PRESCRIPTIVE...0 NO COMPLIANCE PACKAGE (BUILDING ADDITION) R-VALUES R50 CEILING WITH ATTIC SPACE R3 CEILING WITHOUT ATTIC SPACE R3 EXPOSED FLOOR R4 S ABOVE GRADE R0 BASEMENT S.8u VALUE WINDOWS.8u VALUE SKYLIGHTS 4'-6" '-8 /" HOUSE (TO REMAIN) DOOR SCHEDULE Door Tag Width Height Comments D 3' - 0" 6' - 8" EXTERIOR DOOR w/ /4 LITE D ' - 0" 6' - 8" GARAGE ACCESS MAN DOOR w/ SMOKE TIGHT AND WEATHER TIGHT SEAL c/w SELF CLOSING DEVICE D3-6" OVERHEAD GARAGE DOOR w/ OVERHEAD POWER DOOR OPERATOR D5 6' - 0" 6' - 8" SLIDING PATIO DOOR D6 ' - 0" 6' - 8" INTERIOR DOOR w/ GLASS PANEL TO SUIT DOOR OPENING, SITE CONFIRM MEASUREMENTS AS REQUIRED D7 3' - 0" 6' - 8" NEW EXTERIOR DOOR w/ GLASS PANEL AND WEATHER TIGHT SEAL EX 3' - 0" 6' - 8" FRONT DOOR 5'-8 /" TYPICAL FOUNDATION DESCRIPTION 8" POURED CONCRETE (POURED ON 0"X6" POURED CONC. FOOTING ON UNDISTURBED SOIL) W EXTERIOR WITH STONE VENEER DESCRIPTION 3.5" STONE VENEER c/w MASONRY TIES (4" HORIZ. & 6" VERT.) " AIR SPACE 7/6" O.S.B. EXTERIOR GRADE SHEATHING " x 6" WOOD 6" o/c R-4 BATT INSULATION /" GYPSUM BOARD W EXTERIOR WITH VINYL SIDING DESCRIPTION VERTICAL BOARD AND BATTEN VINYL SIDING " x 6" WOOD 6" o/c 7/6" O.S.B. EXTERIOR GRADE SHEATHING R-4 BATT INSULATION /" GYPSUM BOARD INTERIOR x6 PARTITION DESCRIPTION /" GYPSUM BOARD (TAPED AND SEALED ON GARAGE SIDE) TYVEK BUILDING PAPER (COLD SIDE R-4 BATT INSULATION " x 6" WOOD STUDS@ 6" o/c (WARM SIDE) /" GYPSUM BOARD N WINDOW TAG WINDOW SIZE WIDTH HEIGHT WINDOW SCHEDULE HEAD HEIGHT COMMENTS W ' - 5" 5' - 6" - 0" DOUBLE HING WINDOW W ' - 4" 5' - " 6' - 8" DOUBLE HUNG WINDOW ' - 4" 5' - 0" 7' - 3" DOUBLE HUNG WINDOW W4 ' - 0" 3' - 0" 6' - 8" DOUBLE HUNG WINDOW ' - 4" ' - 4" 9' - 0" AWNING WINDOW W6 ' - 4" 5' - " - 0" DOUBLE HUNG WINDOW EXW EXTERIOR DESCRIPTION EX. BRICK VENEER EX. SHEATHING EX. x4 WOOD STUDS EX. FINISH EXW INTERIOR Wg DESCRIPTION EX. x4 WOOD STUDS DENOTES S IN GARAGES TO BE FRAMED WITH x4 STUDS DESCRIPTION Wg EX. WATERPROOFING EX. 8" CONCRETE EX. x4 WOOD STUDS DENOTES S IN GARAGES TO BE FRAMED WITH x4 STUDS 03/30/06 STRUCTURAL STAMP PROVIDED FOR LEDGER DESIGN AND FOUNDATION CONNECTION DESIGN. ALL WINDOWS TO HAVE LOW-E TINTING. ALLOW FOR A MINIMUM OF AN ONE QUARTER INCH (/4") GAP BETWEEN WINDOW UNIT AND FRAMING. THE MINIMUM ROUGH SIZE OPENING (R.S.O) IS TO BE AS REQUIRED BY WINDOW MANUF. TO RESIDENCE MAIN FLOOR PLAN MARCH 4 06 A

3 W4 W4 W4 DN 7'-6" 3'-0 /4" '-4 /4" UN-FINISHED LOFT STORAGE 3'-7 3/4" ONE-STOREY RESIDENCE EXTEND ICE/WATER SHIELD 36" MIN. UP ROOF SLOPE (TYP.) '-9 /" '-5 /4" '-7" 7'-3 /" '-" '-0" ROOF 3/6" = '-0" '-" 3/4" ROOF VENTS AS PER O.B.C. (FT² PER 300 FT² OF INSULATED CEILING AREA) (TYP.) 3'-7" PROVIDE PRE-FINISHED ALUM. STEP FLASHING AS REQUIRED AT ALL /ROOF INTERFACES (TYP.) NOTE: SITE VERIFY ALL ROOF PITCHES TO BLEND WITH NEW ROOF AS REQUIRED/SHOWN 5'-0 /4" 8" / " 8" / " S BELOW (SHOWN DASHED) 8" / " METAL ROOFING '- /" CONTRACTOR TO PROVIDE REQUIRED 48" ICE/WATER SHIELD & PRE-FINISHED METAL ALL VALLEYS (TYP.) NEW VALLEY NEW VALLEY CONTRACTOR TO PROVIDE REQUIRED 48" ICE/WATER SHIELD & PRE-FINISHED METAL ALL VALLEYS (TYP.) 6" / " 6" / " 8" / " 8" / " - /" 9'-0 /" '- /4" 0 7/8" 3/4" 5'-3 3/4" 6" / " 6" / " ROOF W/ METAL CLADDING TO RESIDENCE PLAN & ROOF MARCH 4 06 A3

4 DECORATIVE GABLE TRIM FEATURES AND BRACKETS- HARDIE TRIM OR APPROVED EQUAL T/O ND FLR. TOP PLATE 6' - 0 5/8" HARDI GABLE TRIM DETAILS AND WINDOW SURROUNDS (TYP.) 6'-3" ***TYPICAL NOTES & LABELS (SHOWN ENCLOSED W/ RECTANGLE BORDER). APPLY TO ALL ELEVATION ELEMENTS*** - /8" 3'-3 /" T/O /" DBL. PLT. 7' - /" 0" 6" 5 /" 3'-8 3/8" 5 /" 5 /" dt 9'-3 /4" - /" 5'-6" D3 W W W D STONE VENEER 4" T.O MAIN FLOOR T.O LIVING ROOM FLOOR -' - 3 3/4" -' - 5 /" T.O FOOTING -5' - /" 7 3/4" 4" PRE-CAST MASONRY SILL c/w SLOPED TOP & DRIP GROOVE PROVIDE MIN. 6" PARGED EXPOSED CONCRETE SMOOTH FACE HARDI PANEL CLADDING ON BOXED OUT WINDOW AND GABLES (SHOWN SHADED) ALLIGNED BELOW WINDOWS '- 3/4" FINISHED GRADE TO SLOPE % AWAY FROM BUILDING FOOTINGS/FOUNDATION (REFERENCE FOUNDATION PLAN PLAN) TYPICAL HARDIE 5" CORNER BOARD TREATMENTS (COLOR T.B.D) COLUMNS w/ STONE BASE AND DECORATIVE FIBERGLASS COLUMN PROFILES ABOVE ADDITION RESIDENCE FRONT (WEST) ELEVATION /4" = '-0" TO RESIDENCE FRONT ELEVATION AND PERSPECTIVES MARCH 4 06 A4

5 T/O ND FLR. TOP PLATE 6' - 0 5/8" ***TYPICAL NOTES & LABELS (SHOWN ENCLOSED W/ RECTANGLE BORDER). APPLY TO ALL ELEVATION ELEMENTS*** PRE-FINISHED ALUM EAVES c/w DOWNSPOUTS (TO BE SITE COORDINATED BY CONTRACTOR) - /8" PRE-FINISHED ALUMINUM VENTED SOFFIT c/w INSECT SCREEN (TYPICAL) TYPICAL 8" HARDIE FRIEZE TRIM (COLOR T.B.D) 0" T/O DBL. PLT. /" 7' - /" TYPICAL HARDIE 5" CORNER BOARD TREATMENTS (COLOR T.B.D) HARDI BOARD AND BATTEN SIDING PROVIDE MIN. 6" PARGED EXPOSED CONCRETE 7'- /" '-3 3/4" T.O MAIN FLOOR T.O LIVING ROOM FLOOR -' - 3 3/4" -' - 5 /" '- 3/4" DECORATIVE SUPPORT BRACKETS FINISHED GRADE TO SLOPE % AWAY FROM BUILDING (REFERENCE APPROVED GRADING PLAN) FOOTINGS/FOUNDATION (REFERENCE BASEMENT PLAN) LEFT SIDE (NORTH) ELEVATION /4" = '-0" TO RESIDENCE LEFT SIDE ELEVATION AND PERSPECTIVES MARCH 4 06 A5

6 T/O ND FLR. TOP PLATE 6' - 0 5/8" W4 W4 W4 /" T/O DBL. PLT. 7' - /" REAR ELEVATION TO REMAIN D7 W D5 W T.O LIVING ROOM FLOOR -' - 3 3/4" -' - 5 /" '- 3/4" T.O FOOTING -5' - /" REAR (EAST) ELEVATION) /4" = '-0" TO RESIDENCE REAR ELEVATION AND PERSPECTIVE MARCH 4 06 A6

7 TYPICAL ROOF ASSEMBLY STEEL ROOFING (TO MATCH ) x4 4" O.C. PRE-ENGINEERED ATTIC TRUSSES R-50 BLOWN INSULATION (IN HEATED AREAS) /" GYPSUM BD. (ON UNDERSIDE) /" GYPSUM BOARD STORAGE LOFT BLEND OF AND ROOFING, CONTRACTOR TO SITE VERIFY AND MATCH COLOR, TYPE OF NEW ROOFING TO. OVERLAP TO PROVIDE SEALED JOINT AS REQUIRED T/O ND FLR. TOP PLATE 6' - 0 5/8" '-9 /4" HEEL HEIGHT FLOOR ASSEMBLY ABOVE LIVING RM. 5'-9 3/4" '-4 /4" FLOOR FINISH (VARIES PER ROOM) 3/4" T+G FLOOR SHEATHING (GLUED AND 6'-7 3/4" NAILED) x0 FLOOR JOISTS (ROOF TRUSS BOTTOM CHORD) R-3 SPRAYED POLYURETHANE INSULATION (TO MEET REQUIREMENTS AS A AIR/VAPOUR BARRIER /" GYPSUM BOARD 4'- /4" - /8" 0" 4'- /4" - /8" 0" OVERFRAMING TO BLEND NEW AND ROOFS T/O DBL. PLT. /" 7' - /" FOLD DOWN SHIP LADDER TO ACCESS STORAGE LOFT ABOVE LIVING AREA ARCHWAY Wg 9'-" GARAGE (WITH STORAGE LOFT ABOVE) 0'-5" 9'-3 /4" T.O FOUNDATION -' - /" 5" CONC. SLAB ON GRADE 6" X 6" X 6 6 W.W.M. ON 8" CLEAR CRUSHED STONE '-5 /4" /" T.O MAIN FLOOR T.O LIVING ROOM FLOOR -' - 3 3/4" -' - 5 /" T.O FOOTING -5' - /" 3'-6" LIVING AND GARAGE SECTION /4" = '-0" DISTANCE FROM TOP OF FLOOR ELEVATION TO TOP OF FOUNDATION BETWEEN GARAGE AND HOUSE (SITE FOUNDATION COORDINATE AND VERIFY) GARAGE/HOUSE TRANSITION TO BE SITE VERIFIED FOR HEIGHT BASED ON FLOOR ELEVATION FLOOR ASSEMBLY ABOVE GRADE FLOOR FINISH (VARIES PER ROOM) 3/4" T+G FLOOR SHEATHING (GLUED AND NAILED) x FLOOR JOISTS R-3 SPRAYED POLYURETHANE INSULATION (TO MEET REQUIREMENTS AS A AIR/VAPOUR BARRIER PROVIDE PLYWOOD BACKING OR EQUAL BETWEEN EACH JOIST CAVITY TO PROVIDE SPRAY BACKING FOR INSULATION '-0" CONCRETE SLAB (TO REMAIN IN PLACE) -x4 LEDGER w/ /" DIA. LAG 6" O.C. 4" INTO SOLID CONCRETE/MASONRY GIRDER TRUSS (BEYOND) T/O ND FLR. TOP PLATE 6' - 0 5/8" x0 CEILING JOIST AND x0 ROOF JOIST LADDER 4" O.C. BETWEEN GIRDER AND END GABLE T/O DBL. PLT. /" 7' - /" FOLD DOWN SHIP LADDER TO ACCESS STORAGE LOFT ABOVE T.O MAIN FLOOR T.O LIVING ROOM FLOOR -' - 3 3/4" -' - 5 /" CROSS SECTIONS CROSS SECTION /4" = '-0" 03/30/06 STRUCTURAL STAMP PROVIDED FOR LEDGER DESIGN AND FOUNDATION CONNECTION DESIGN TO RESIDENCE MARCH 4 06