Abuilding s Wire Management System may be able to

Size: px
Start display at page:

Download "Abuilding s Wire Management System may be able to"

Transcription

1 Cellular Raceway, Junction Boxes, Fittings, and Headerduct Walkercell Cellular Raceway Abuilding s Wire Management System may be able to accommodate demands on it when the building is first occupied. But what about two, five, or ten years from now. A Walkercell Cellular Raceway System offers many advantages to your building to avoid considerable future expenses. A Walkercell System can be provided in varying sizes to customize the capacity required for the building with the product to be supplied. As business needs change, office space requirements change. A Walkercell System has flexibility built in with a grid of presets throughout the office area making it possible for activations and deactivations to be made quickly and efficiently. A Walkercell System activated by a recessed activation makes a fully utilized preset nearly unnoticeable, and the preset grid pattern can be designed so that a preset will be located under a workstation. A Walkercell System is designed to reduce life cycle cost by minimizing the cost of adds, moves, and changes, and controlling installed cost. Walkercell is UL Listed to U.S. and Canadian safety standards. Walkercell Raceway. Features & Benefits Three-in-one configuration. Brings three compartments into a single raceway only one raceway to purchase and install for each distribution run. Triple service preset. Brings up to three services to the workstation at one location which eliminates the need for multiple access points. Bend Radius Control at preset. Reduces signal loss or distortion due to tight turns of cables. AutoCAD drawings. Can be electronically transmitted via the internet or loaded onto CD for imported quality and cost reduction of drawing transmittals. UL scrub water approved activation kits. New FloorPort Service Fittings provide protection from floor cleaning devices such as carpet scrubbers and wet mops. Datacom connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point-of-use. A wide selection of data and bezel options available for use with Ortronics TracJack and Series II devices. Sold by: Walkercell Cellular Raceway distribution with Trenchduct Feeder System. Toll Free: (877) ED809R8 Updated August 2007 For latest specs visit

2 Walkercell Raceway WCR11/2-10/B Walkercell Raceway Profile WCR11/2. WCR11/2-10/24 Walkercell Raceway Top View 10' [3m] long without preset openings. WCR11/2-10/24 Walkercell Raceway Profile WCR11/2. 10' [3m] long with prepunched preset openings 24" [610mm] on center " [403mm] 1 1 8" [29mm] 5 7/8" [149mm] 8.2 sq. in. [5264 sq. mm] 4 1 4" [108mm] 4.22 sq. in. [2722 sq. mm] 8.2 sq. in. [5264 sq. mm] 1 1 2" [38mm] 17 5/8" [448mm] WCR2-10/B Walkercell Raceway Profile WCR2. WCR2-10/B Walkercell Raceway Top View 110' [3m] long without preset openings. WCR2-10/24 1 3/1 [30mm] Walkercell Raceway Profile WCR2. 10' [3m] long with prepunched preset openings 24" [610 mm] on center. WCR3-10/B Walkercell Raceway Profile WCR3. WCR3-10/24 Walkercell Raceway Top View 10' [3m]] long without preset openings. WCR3-10/24 2 3/1 [56mm] 7 7/8" [200mm] 4 1 4" [108mm] 3 1/4" [83mm] 3 1 4" [83mm] 1 15/1 [49mm] 11.0 sq. in. [7097 sq. mm] 7 7/8" [200mm] 18.8 sq. in. [12130 sq. mm] 3 1 4" [83mm] 4.3 sq. in. [2774 sq. mm] 21 3/4" [552mm] 11.0 sq. in. [7097 sq. mm] Walkercell Raceway Profile WCR3. 10' [3m] long with prepunched preset openings 24" [610mm] on center " [108mm] 8.5 sq. in. [5484 sq. mm] 3 1 4" [83mm] 18.8 sq. in. [12130 sq. mm] 2 15/1 [75mm] 21 3/4" [552mm] Walkercell Cable Fill Capacities Communications DIAMETER AREA WCR11/2 WCR2 WCR3 (IN 2 ) (8.2 SQ. IN. (11 SQ. IN. (18.8 SQ. IN. [5264 SQ. MM]) [7097 SQ. MM]) [12130 SQ. MM]) Inches [MM] Inches 2 [MM 2 ] 40% FILL 40% FILL 40% FILL UNSHIELDED TWISTED PAIR 4-pair, CAT [5.6].038 [24.5] pair, CAT [6.4].049 [31.7] TELEPHONE 2-pair, 24 AWG.140 [3.5].015 [9.9] pair, 24 AWG.190 [4.8].028 [18.1] pair, 24 AWG.410 [10.4].132 [85.2] COAXIAL RG58/U.195 [4.9].030 [19.4] RG59/U.242 [6.1].046 [29.7] RG6/U.270 [6.8].057 [36.8] SHIELDED TWISTED PAIR TYPE [9.9].119 [76.8] TYPE [11.8].170 [109.7] TYPE [6.2].047 [30.3] FIBER OPTIC 2-strand.180 [4.6].025 [16.1] strand.190 [4.8].028 [18.1] strand.210 [5.3].035 [22.6] FIBER ZIP CORD.110 [2.8].010 [6.5] Walkercell Wire Fill Capacities Power WCR11/2 WCR2 WCR3 WIRE AREA (IN 2 ) (4.22 SQ. IN. (4.3 SQ. IN. (8.5 SQ. IN. SIZE DIA. SQ. IN/ [2722 SQ MM]) [2774 SQ MM]) [5484 SQ MM]) AWG IN/MM SQ. MM 40% FILL 40% FILL 40% FILL [2.8] [6.5] [3.3] [8.4] [4.1] [13.5] [5.4] [23.9] [6.4] [32.9] [8.2] [52.9] NOTE: Cable diameters can vary depending on manufacturer. Verify diameter and adjust fill capacities as required. 2

3 PK150 PK200 PK250 PK300 PK325 PK Series Presets and Extensions Triple Service Preset Zinc die-cast construction with a removable steel cap that is recessed for concrete. Each preset is capable of housing two duplex power receptacles and up to eight communication connectors. Each preset has tapped openings for mounting brackets, adjusting ring and trim rings. The presets are field installed using one 3/1 [4.8mm] pop rivet (not provided). Preset extensions can be used to add height to presets as needed. See preset selection guide below to determine correct preset. A Height Above Preset PKER-10 1" [25mm] PKER Extensions Attaches PKER /2" [38mm] to preset to add height to PKER-20 2" [51mm] preset. Can be field installed. PKER /2" [64mm] PKER-30 3" [76mm] Mudcap Extension Ring PK Preset A 9 5/1 [237mm] WCR11/2 9 5/8" [244mm] Minimum System Depth Preset PK150 *1 8" min. [3.2mm] Finished Floor 2" [51mm] 1 1/2" [38mm] Preset Selection Guide Minimum System Minimum System Depth Preset PK150 Depth 4 1/2" [114mm] Preset PK150 *1 8" min. [3.2mm] Finished Floor *1 8" min. [3.2mm] Finished Floor WCR " [38mm] 2" [51mm] WCR " [38mm] 3" [76mm] OTHER SYSTEM DEPTHS FOR WCR11/2 SYSTEM DEPTH PRESET CAT. NO. FILL OVER CELL PK150 2" [51mm] 4" [102mm] PK /2" [64mm] 4 1/2" [114mm] PK250 3" [76mm] OTHER SYSTEM DEPTHS FOR WCR2 SYSTEM DEPTH PRESET CAT. NO. FILL OVER CELL PK /2" [38mm] 4" [102mm] PK200 2" [51mm] 4 1/2" [114mm] PK /2" [64mm] OTHER SYSTEM DEPTHS FOR WCR3 SYSTEM DEPTH PRESET CAT. NO. FILL OVER CELL 4 1/2" [114mm] PK /2" [38mm] 5" [127mm] PK200 2" [51mm] 5 1 2" [140mm] PK " [64mm] 5" [127mm] PK /4" [133mm] PK /4" [95mm] 5 1/2" [140mm] PK350 4" [102mm] 5" [127mm] PK300 3" [76mm] 5 1/4" [133mm] PK /4" [83mm] 5 1/2" [140mm] PK350 Recommend a minimum of 1/8" [3.2mm] concrete over preset. *If concrete depth over preset is over 3/4" [19.1mm] it may be difficult to break-out concrete and excessive spalling may occur. For system depth greater than above standard preset height use PK Extension Ring. PK300 3" [76mm] 6 1/4" [159mm] PK " [83mm] 6 1/2" [165mm] PK350 PKCAP Mudcap and Raceway Marker Caps Mudcap Used to close off Walkercell PK Preset. PMS-415N Marker Cap Replaces standard mudcap at ends of runs and near feeder to locate cellular runs after concrete placement. 3

4 RSCB-18 RSCB-28 RSCB-38 RSCB-48 Walkercell System Components Raceway Supports Holds raceway at proper elevation during concrete placement. Fasten raceway to support using four self-drilling screws supplied. Supports are used at raceway butt joints and maximum 5' [1.524m] spacing between butt joint locations. See selection guide below. Suffix indicates distance between Walkercell and slab on grade. RGP Grounding Plate Installed at raceway butt joints when Walkercell is placed on a mud slab or concrete sidewalks and RSCBs are not required. Used to maintain ground continuity between Walkercell Raceways. Fasten raceway to slab through 20 gauge grounding plate with power actuated fastener (not provided). Field installed. 26 1/2" [673mm] 2 7/1 [62mm] 3" [76mm] 24" Min. [610mm] 26 3/4" [679mm] REC11/2 (For WCR11/2) REC (For WCR2/WCR3) Blank End Closures Used to close off ends of raceway. End closures are held in place during concrete placement using blind rivets or welds. System Depth 16 1/2" [419mm] 1 1/2" [38mm] 1/2" Min. [12.7mm] Depth Below Cell REC11/2 1" [25mm] CAT. NO. SUFFIX HEIGHT ADJUSTMENT -18 1/2" [12.7mm] to 1 7/8" [48mm] /2" [38mm] to 2 7/8" [73mm] /2" [64mm] to 3 7/8" [98mm] 2 29/32" [74mm] REC 1 29/32" [48mm] Important: 1. 2" [51mm] concrete below cell is recommended for monolithic pours requiring a fire-rated floor slab. 2. For floor slab on grade, a batch of concrete should be poured around each support prior to the final pour. 3. Vapor barrier recommended. CBR-HT CBR-LT CBR11/2-LHT CBR-LHT CBR-HT (For Power Only) 4 1/8" [105mm] Cell Boot Risers Allow access into one, two, or three cells simultaneously. Field cut oblong opening in raceway and rivet or weld riser to raceway. Void closures included (not shown). CBR-LT (Access to Two Communication Compartments) 12" [305mm] CBR11/2-LHT (Access to All Three Compartments with Power Separated) 4 1/8" [105mm] CBR-LHT (Access to All Three Compartments with Power Separated) 4 1/8" [105mm] 30" [762mm] 30" [762mm] 30" [762mm] 30" [762mm] 12" [305mm] 12" [305mm] For WCR11/2 For WCR2/WCR3 4

5 REC11/2-C REC2-C REC3-C REC11/2-C (For WCR11/2) 1/2" [12.7mm] and 3/4" [19.1mm] concentric KOs 1/2" [12.7mm] 16 1/2" [419mm] REC2-C (KOs for WCR2) Walkercell System Components (Continued) End Closures Used to close off ends of raceway and provide conduit knockouts. End closures are held in place with blind rivets or welds. 1 1/2" [38mm] 1" [25mm] (For WCR11/2) Junction Box Adapters (For WCR2/WCR3) Side adapter to attach Walkercell Raceway to the box. Allows junction box side opening to be converted to another size by replacing adapter. WCR3 cannot be used with 2 1/2" deep [64mm] box. 22 5/8" [575mm] 22 5/8" [575mm] 7/8" [22.2mm] 7/8" [22.2mm] 1" [25mm] 1" 3/4" [25mm] [19.1mm] 1/2" [12.7mm] 3/4" 1" 1" [19.1mm] [25mm] [25mm] 1 15/1 [49mm] 1 1/1 [27mm] 11/2JBC-CA 22JBC-CA 33JBC-CA Junction Box Closure With Duct Stubs Provides ability to feed conduit from junction box. Use with 312 Fittings. REC3-C (KOs for WCR3) 1 1/4" 1" 3/4" 3/4" 1" 3/4" 1" 1 1/4" [32mm] [25mm] [19.1mm] [19.1mm] [25mm][19.1mm] [25mm][32mm] 2 15/1 [75mm] 1 1/1 [27mm] REC11/2-CA End Closures With No. 2 REC2-CA Duct Stubs Provides ability REC3-CA to feed conduit from ends of raceway. Use with 312 Fittings below. 22AER-11/2-21/4 Adjustable Extension Ring 22AER-23/8-31/8 Attaches to ring on junction box to provide extension height from 1 3/8" to 2 1/8" [35mm to 54mm] or 2 1/4" to 3" [35mm to 76mm] over top of junction box. Select hardware bag below to attach ring to box. AERHB-116 Hardware Bag For -132 adjustable extension ring Suffix indicates depth of -200 concrete over junction box -048 cover. Use chart below to determine hardware bag required /4 [19.1mm] Female Conduit Adapter -1 [25mm] Fits on outside of No. 2 duct. -11/4 [32mm] For one EMT conduit. Suffix -11/2 [38mm] indicates conduit size. -2 [51mm] 22LHS-1/8 Carpet and Tile Holders 22LHS-1/4 Placed on top of junction box cover plates to provide trim for flooring. Recessed to hold carpet or tile. Specify B for brass or S for steel. Suffix indicates depth. Hardware Bag Concrete Depth Over Walkercell Cat. No. 1 1/2" 1 5/8" 1 3/4" 1 7/8" 2" 2 1/8" 2 3/8" - 3" AERHB-116 X AERHB-132 X X AERHB-148 X X AERHB-200 AERHB /2JBC (For WCR11/2) Junction Box Closure 22JBC (For WCR2) Attaches to side of junction 33JBC (For WCR3) box to close access. X X 5

6 11/2JB JB JB /2JB JB3510 Junction Boxes and Headerduct Junction Boxes Used at intersections of Walkercell Raceway. Partitions inside box maintain separation of services. 22" [559m] dia. cover provides access inside box. Access ring is 1" [25mm] over box. Order extension ring for additional height (see page 5). Cover plates have 1/2" [12.7mm] upward adjustment for precise leveling after the pour. Side openings on junction boxes can be replaced to fit other Walkercell profiles. Select replacement adapter on page 5. Selection Chart CATALOG NO. SIDE OPENINGS HEIGHT OF BOX 11/2JB2510 Four WCR11/2 2 1/2" [64mm] 22JB2510 Four WCR2 2 1/2" [64mm] 33JB3510 Four WCR3 2-11/2JB2510* Two WCR11/2, Two WCR2 2 1/2" [64mm] 32JB3510* Two WCR2, Two WCR3 *WCR2 feeds WCR11/2 distribution and WCR3 feeds WCR2 distribution. JBH Series Junction Box Header Used as a large capacity feeder system for Walkercell. Cellular raceway attaches to side of box. 22" [559mm] dia. cover plate access at center of unit. Standard length is 60" [1524mm]. The minimum depth of any JB, JHB, or HJB is 1/2" [12.7mm] higher than the deepest cellular raceway profile being coupled in the box. Select product from charts below. Junction Box Headers Used With WCR11/2 Catalog Body Body Ring Syst. Power Power Communication Number Width Depth Height Depth Capacity [sq. in. mm 2 ] Comp. Width Capacity [X2, sq. in. mm 2 ] 11/2JBH " 2 1/2" 1" 3 1 2" /4" [610mm] [64mm] [25mm] [4283.9mm 2 ] [108mm] [ mm 2 ] 11/2JBH " 2 1/2" 1 1/2" /8" [762mm] [64mm] [38mm] [5574.2mm 2 ] [130mm] [ mm 2 ] 11/2JBH /2" 1 1/2" 4" [915mm] [64mm] [38mm] [102mm] [6851.6mm 2 ] [ mm 2 ] Junction Box Headers Used With WCR2 Catalog Body Body Ring Syst. Power Power Communication Number Width Depth Height Depth Capacity [sq. in. mm 2 ] Comp. Width Capacity [X2, sq. in. mm 2 ] 2JBH " 2 1/2" 1" 3 1 2" /4" [610mm] [64mm] [25mm] [4283.9mm 2 ] [108mm] [ mm 2 ] 2JBH " 2 1/2" 1 1/2" 4" /8" [762mm] [64mm] [38mm] [102mm] [5574.2mm 2 ] [130mm] [ mm 2 ] 2JBH /2" 1 1/2" 4" [915mm] [64mm] [38mm] [102mm] [6851.6mm 2 ] [ mm 2 ] NOTE: All capacities based on a minimum 80% allowance where cables may encounter a restriction point inside of junction box. (There are no hidden restricted areas inside of junction box.) Consult factory for WCR3 capacities. HJB Series Header Junction Boxes Used at intersections of Headerduct and junction box headers. 22" [559mm] dia. cover plate access at center of unit. Standard length is 60" [1542mm]. Select product from charts above, changing the prefix of the catalog number from JBH to HJB. Important! The Headerduct feeding into the side of the Header Junction Boxes must be 1/2" [12.7mm] shallower than the box. 6

7 WCHD WCHD WCHD Headerduct Components Walkercell Headerduct Used as a feeder raceway for Walkercell Systems. Standard length is 60" [1524mm]. All Headerduct is furnished with 1/4-20 threaded holes at each end to fasten coupling channels. Select product from chart below. A Walkercell Headerduct Catalog No. A B 60" [1524mm] WCHD " [610mm] 2 1/2" [64mm] WCHD " [762mm] 2 1/2" [64mm] WCHD [915mm] 2 1/2" [64mm] B JBHCC24 JBHCC30 JBHCC36 Coupling Channels Used to connect ends of Headerduct Junction Boxes together. Channels are furnished with 1/4-20 screws. B A Headerduct Coupling Channel Catalog No. A B JBHCC24 24" [610mm] 2 1/2" [64mm] JBHCC30 30" [762mm] 2 1/2" [64mm] JBHCC36 3 [915mm] 2 1/2" [64mm] JBHEC2425 JBHEC3025 JBHEC3625 Header End Closure Used to close end of Headerduct, Header Junction Boxes, or Junction Box Header. Select product from chart below. Secured with blind rivet or weld. B A Headerduct End Closure Catalog No. A B JBHEC " [610mm] 2 1/2" [64mm] JBHEC " [762mm] 2 1/2" [64mm] JBHEC [915mm] 2 1/2" [64mm] 7

8 Walkercell System Layout JBHCC24 CBR-LHT S36BBTCAL 2-11/2JB2510 PK200 11/2JBH WCR11/2-10/24 RSCB-28 WCR2-10/B Diagram is for part illustration only. Does not represent typical system layout. A wide variety of service fittings are available to meet many applications. See ED1144 for full details. Service Fittings Sold by: FloorPort flush and recessed activations for power and communication. Toll Free: (877) Wiremold / Legrand U.S. and International: 60 Woodlawn Street West Hartford, CT FAX Outside U.S Canada: 570 Applewood Crescent Vaughan, Ontario L4K 4B FAX Copyright 2007 Wiremold / Legrand All Rights Reserved ED809R8 Updated August 2007 For latest specs visit