NEXT-GENERATION SEALER TECHNOLOGY GL OBAL, I N C.

Size: px
Start display at page:

Download "NEXT-GENERATION SEALER TECHNOLOGY GL OBAL, I N C."

Transcription

1 NEXT-GENERATION SEALER TECHNOLOGY GL OBAL, I N C.

2 NEXT-GENERATION SEALER TECHNOLOGY DRIVEWAY SEALER JOINT STABILIZER & SEALER The Molecule line of sealer products represents nextgeneration water-based technology for premium hardscape protection. It penetrates the surface to provide robust stain resistance without leaving a film or altering the natural aesthetic. Molecule products are VOC-free, ready-to-use out of the bottle, and easy to apply. VERTICAL MASONRY SEALER HARDSCAPE SHAMPOO

3 Concrete Porous Pavers Dense Pavers 400 ft 2 /gal README.TXTTOP 5 TIPS Molecule [DS] should be installed within an ambient low sunlight, or colder areas will lengthen cure times. Conversely, direct sun, warmer areas will shorten cure times. Avoid temperatures at or below freezing or above 100º F for application, curing phase, or storage. Molecule [DS] is a water-based, fluoropolymer, penetrating sealer. The curing phase is dependent upon complete evaporation of the water component (usually 4-12 hours in optimal daytime conditions). Apply Molecule [DS] in one single application coat. Do not divide recommended application rates into multiple coats. Always consult manufacturer coverage rate guidelines, or contact our Technical Support desk by phone , or by Info@TechniSoil.com. Concrete Pavers Natural Stone DRIVEWAY SEALER 01. Clean & Prepare 02. Apply Molecule [DS] 03. Squeegee Surface Do not apply Molecule [DS] within a minimum of 24 hours before or after rainfall. In excessively wet conditions, allow project area to dry completely before application. Clean driveway thoroughly before applying. Molecule [DS] should not be applied over the top of other sealers, stains, efflorescence, or dirt as it may affect adhesion, cure, and finished aesthetic Molecule [DS] reduces tracking from vehicle tires, resists staining from debris and liquids, and limits freeze-thaw damage

4 The Molecule [JSS] hybrid polymer formula provides robust stain resistance without leaving a film and locks paver joint sand in place. Porous Pavers (up to 1/4 joints) 150 ft 2 /gal Pavers Stone Brick 01. Clean & Prepare 02. Install Jointing Material 03. Apply Molecule [JSS] 04. Squeegee Surface Dense Pavers (up to 1/4 joints) TOP 5 TIPS 250 ft 2 /gal Molecule [JSS] should be installed within an ambient low sunlight, or colder areas will lengthen cure times. Conversely, direct sun, warmer areas will shorten cure times. Avoid temperatures at or below freezing or above 100º F for application, curing phase, or storage. Molecule [JSS] is a hybrid formulation, water-based, penetrating sealer. The curing phase is dependent upon complete evaporation of the water component (usually hours in optimal conditions). Apply Molecule [JSS] in one single application coat. Do not divide recommended application rates into multiple coats. Always consult manufacturer coverage rate guidelines, or contact our Technical Support desk by phone , or by Info@TechniSoil.com. Do not apply Molecule [JSS] within a minimum of 24 hours before or after rainfall. In excessively wet conditions, allow project area to dry completely before application. Clean hardscape surface thoroughly before applying. Molecule [JSS] should not be applied over the top of other sealers, stains, efflorescence, or dirt as it may affect adhesion, cure, and finished aesthetic. JOINT STABILIZER & SEALER

5 Vertical Brick, Blocks & Stone ft 2 /gal TOP 5 TIPS Molecule [VMS] should be installed within an ambient low sunlight, or colder areas will lengthen cure times. Conversely, direct sun, warmer areas will shorten cure times. Avoid temperatures at or below freezing or above 100º F for application, curing phase, or storage. Molecule [VMS] is a water-based, fluoropolymer, penetrating sealer. The curing phase is dependent upon complete evaporation of the water component (usually 4-12 hours in optimal daytime conditions). Apply Molecule [VMS] in one single application coat. Do not divide recommended application rates into multiple coats. Always consult manufacturer coverage rate guidelines, or contact our Technical Support desk by phone , or by Info@TechniSoil.com. Do not apply Molecule [VMS] within a minimum of 24 hours before or after rainfall. In excessively wet conditions, allow project area to dry completely before application. Clean surface thoroughly before applying. Molecule [VMS] should not be applied over the top of other sealers, stains, efflorescence, or dirt as it may affect adhesion, cure, and finished aesthetic. VERTICAL MASONRY SEALER Molecule [VMS] is specifically designed for vertical applications such as stone veneer, stucco, and brick masonry. It penetrates to reduce staining from graffiti, debris, and foreign liquids while limiting freeze-thaw damage. 01. Clean & Prepare 02. Apply Molecule [VMS] Brick Stone Block

6 01. Apply Molecule [HS] When used regularly, Molecule [HS] maintains and extends the life of any Molecule brand hardscape sealer coating. Concrete 02. Scrub Surface The simple wash and wax application process cleans and protects your hardscape investment. Molecule [HS] is environmentally safe and ready-to-use out of the bottle. HARDSCAPE SHAMPOO Porous Pavers TOP 5 TIPS Molecule [HS] should be applied within an ambient low sunlight, or colder areas will lengthen workability times. Conversely, direct sun, warmer areas will shorten workability times. Avoid temperatures at or below freezing or above 100º F for application or storage. Do not allow Molecule [HS] to dry completely on surfaces before or after scrubbing. If shampoo dries, reapply shampoo over dried area, scrub, and rinse as soon as possible. 03. Rinse with Water Molecule [HS] contains a supplemental sealer component designed to penetrate and bolster original applications. It can be used to clean and prepare surfaces for Molecule brand sealer applications and for regular wash and wax maintenance coats afterward. Avoid overspray onto adjacent surfaces such as houses, sheds, cars, or other surfaces as it can stain if allowed to dry. Mask or shield while applying to prevent overspray. Clean overspray areas immediately by scrubbing and rinsing with water as needed. Pavers Stone Brick For general maintenance, Molecule [HS] can be applied and rinsed off with high pressure water. For tougher staining, scrub shampoo with soft to medium bristle brush before rinsing with water.

7 GL OBAL, I N C. Made with pride in the USA