AC R1 # Triangle Parkway Suite 100 Norcross, Ga Phone: Fax: AC R1. September 11, 2012

Size: px
Start display at page:

Download "AC R1 # Triangle Parkway Suite 100 Norcross, Ga Phone: Fax: AC R1. September 11, 2012"

Transcription

1 AC R1 #12

2 AC R1 #12 AC R1 September 11, 2012 Mr. Brian Gerber Ms. Elyse Levy International Code Council Evaluation Service (ICC ES) 5360 Workman Mill Road Whittier, CA RE: Agenda item 12: Acceptance Criteria AC70 Dear Mr. Gerber and Ms. Levy, I am writing concerning the proposed paragraph to be added to section 6.0 on Interior, Nonstructural Walls. The transverse pressure for this application should be 10 PSF at a minimum, and even include an exception up to 15 PSF for specific applications. The American Iron and Steel Institute (AISI) has included this 10 PSF limit in both AISI S200, and the new AISI S North American Standard for Cold Formed Steel Framing Nonstructural Members. I was involved in the discussions leading up to both limits, and provide the following points: Part of the committee concern was to exclude the exterior building envelope from the applicability of nonstructural partitions. Therefore, wording was added to AISI S220 to exclude the gravity load resisting system, lateral force resisting system, or building envelope. This is part of the definition of nonstructural member. There was a concern that allowing pressures greater than 10 PSF would permit these members and systems to be used to resist wind loads. The above exclusion prohibits that usage. Furthermore, the AISI S220 document permits an exception for pressurized air plenums, ceilings, and elevator shaft enclosures, with allowable design pressures up to 15 PSF. With respect to section of ASCE 7 10, this could be referenced in this section, but should not be used to justify a 5 PSF pressure limitation. Seismic loads are definitely not pressures: seismic loads must be considered in multiple directions other than just transverse. Section includes exceptions that are not stated in the proposed paragraph. A revised proposed paragraph is included as an attachment, along with referenced sections from AISI S220 and ASCE Sincerely, DSi ENGINEERING, LLC Don Allen, P.E. Senior Engineer enclosure 5550 Triangle Parkway Suite 100 Norcross, Ga Phone: Fax:

3 AC R1 Attachment 1 Proposed rewording of paragraph to be added to section 6.0 of AC70, that would appear in the design section of evaluation reports: Interior, Nonstructural Walls: For interior, nonstructural walls that are not subject to sustained tension loads, the power-driven fasteners described in Section # may be used to attach steel track to concrete or steel in all Seismic Design Categories, provided substantiating data or calculations are submitted addressing the connection capacity. Track and stud members supported by these power-driven fasteners must qualify as nonstructural members in accordance with the nonstructural member definition and scope statement in AISI S220. In addition, limitations in section of ASCE 7-10 shall be considered. The design load on the fastener must not exceed the allowable load shown in Tables #, # and #, as applicable. For reference: Applicable portion of AISI S220 scope statement: This standard applies to nonstructural members that comply with the following: 1) Member is in a steel-framed system that is limited to a transverse (out-of-plane) load of not more than 10 lb/ft 2 (0.48 kpa). Exception: Pressurized air plenums, ceilings and elevator shaft enclosures are permitted to have a load of not more than 15 lb/ft 2 (0.72 kpa). 2) Member is in a steel-framed system that is limited to a superimposed axial load, exclusive of sheathing materials, of not more than 100 lb/ft (1.46 kn/m). 3) Member is limited to a superimposed axial load of not more than 200 lbs (0.89 kn). AISI S220 definition of nonstructural member: Nonstructural Member. A member in a steel framed system that is not a part of the gravity load resisting system, lateral force resisting system or building envelope. ASCE 7 10 section , with exception: Partitions General Partitions that are tied to the ceiling and all partitions greater than 6 ft (1.8 m) in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling lateral force bracing. Bracing shall be spaced to limit horizontal deflection at the partition head to be compatible with ceiling deflection requirements as determined in Section for suspended ceilings and elsewhere in this section for other systems. EXCEPTION: Partitions that meet all of the following conditions: 1. The partition height does not exceed 9 ft (2,740 mm). 2. The linear weight of the partition does not exceed the product of 10 lb (0.479 kn) times the height (ft or m) of the partition. 3. The partition horizontal seismic load does not exceed 5 psf (0.24 kn/m 2 ) Glass Glass in glazed partitions shall be designed and installed in accordance with Section Triangle Parkway Suite 100 Norcross, Ga Phone: Fax:

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37 AC R1 #12 Subject: Comments on Proposed Revisions to ICC-ES AC70 September 11, 2012 Dear Mr. Gerber, Hilti is offering the following public comments on your letter dated August 21 st, 2012 regarding proposed revisions to ICC-ES AC70 Acceptance Criteria for Power-Driven Fasteners in Concrete, Steel and Masonry Elements. In reference to Item 8 in your letter, Hilti does not believe that a 5 psf limitation should be placed on the transverse load of the partition wall. We believe that this is an incorrect and overly conservative interpretation of the code. Instead, AC70 and the ESRs should simply point the Design Professionals and Building Officials to the relevant code sections for the particular application. We feel that since engineering calculations are required to be submitted to the Building Official, the Design Professional should use their judgment as to what type of fastening system to use and justify that use through calculations that are submitted to the Building Official for the project. Our proposed alternative language is as follows: Interior Walls and Partitions: For interior walls and partitions that are not subject to sustained tension loads, the power driven fasteners described in Section 3.1 may be used to attach steel track to concrete or steel in all Seismic Design Categories, where the design is done in accordance with IBC Section and ASCE 7-10 Section , provided substantiating calculations are submitted addressing the fastener-tobase material capacity and the fastener-to-attached material capacity. Interior walls and partitions are limited to locations where bearing walls, shear walls or braced walls are not required by the approved plans. The design load on the fastener must not exceed the allowable load shown in Tables 2, 3, 4 and 5, as applicable. In particular, IBC 2012 Section states Interior walls and partitions that exceed 6 feet (1829 mm) in height, including their finish materials, shall have adequate strength to resist the loads to which they are subjected but not less than a horizontal load of 5 psf (0.240 kn/m 2 ). This contradicts the language proposed by ICC-ES. Imposing a 5 psf transverse load limitation on this very common application would essentially render it undoable with power-driven fasteners, which have been used safely and successfully for cold-formed steel track attachments for many decades in seismic and non-seismic regions. The ICC-ES proposed load limitation of 5 psf is not reasonable and will damage both the cold-formed steel industry and the fastener industry. If the AC hearing discussion additional and arbitrary load limitations are imposed, then Hilti Hilti, Inc South 122 nd East Avenue Tulsa, OK

38 would prefer to not include this language in ICC-ES AC70 or the ESRs at all, as it has not been done historically in this context. Doing so would significantly impact our business in a negative way. Furthermore, it should also be noted that power-driven fasteners are specifically approved for use in partition wall track fastening applications by OSHPD in California. If power-driven fasteners are acceptable for OSHPD, then they should be acceptable to ICC-ES. Regards, William G. Gould, P.E. Director, Codes & Approvals Hilti, Inc. Hilti, Inc South 122 nd East Avenue Tulsa, OK

39 AC R1 #12

40 AC R1 #12

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61 1 of 4 Design Example 1 - Full Height Partition Wall 9/4/2012 CFS Interior Nonstructural Walls - Using Power Driven Fasteners Outline This example will illustrate the following parts of the design process A. Transverse (out-of-plane) loads on interior nonstructural walls B. Design of CFS stud size and spacing C. Distribution of transverse (out-of-plane) loads to the CFS anchorage D. Allowable service load for fasteners driven into steel and concrete Given Information Interior Nonstructural Wall (Full Height Partition Wall): Partition Wall Height = 14'-0" 1/2" Gypsum Wallboard each side Dead Load of Interior Nonstructural Wall (Table C3-1, ASCE 7-10) = 8 psf Ceiling : Separation joint between Partition Wall and Ceiling meeting Ceiling horizontal deflections requirements of ASCE 7-10 z/h = 1.0 (Value 1.0 allows for installation at any floor or roof level of the building) CFS stud and runner (track)material strength: F y = 33 ksi ; F u = 45 ksi Power Driven Fasteners fastening to: Case 1, Structural Steel Support, 3/16" thick steel, ASTM A36 Case 2, 4" thick, normal-weight Concrete, f'c = 2500 psi Code Level Seismic Design Lateral Load Criteria: I p (Component Importance factor per Section , ASCE 7-10) = 1.5 S DS (Spectral acceleration, short period) = 1.95 A - Transverse (out-of-plane) Loads on Interior Nonstructural Walls 1. Interior walls and partitions that exceed 6'-0" in height,--- shall have adequate strength to resist the loads to which they are subjected to but not less than a horizontal load of 5 psf, per Section of 2012 IBC. 2. For all Seimic Design Categories (A, B, C, D, E and F) Seismic Design Force shall be calculated per Section of ASCE Partitions that are tied to the ceiling and all partitions greater than 6 ft in height shall be laterally braced---. Bracing shall be spaced to limit horizontal deflection---. EXCEPTION: , 3. The partitition horizontal seismic load does not exceed 5 psf, per Section of ASCE Maximum transverse (out-of-plane) load is limited to 10 psf for Non-Structural member, per Section A2, Definitions of AISI S200. Generally ASD seismic transverse loads (0.7E) calculated per A 2 above are less than 5psf, thus minimum transverse load of 5 psf specified per A 1 above governs. Note that 10psf limit specified in A4 above is not a minimum transverse load for the design of non-structural member.

62 2 of 4 B - Design of CFS stud size and spacing 9/4/ Seismic Design Force: F p = 0.4 a p S DS W p (1 + 2 (z/h)) (R p /I p ) (13.3-1) F p 1.6S DS I p W p (13.3-2) = 1.6x1.95x1.5W p = 4.68W p F p 0.3S DS I p W p (13.3-3) = 0.3x1.95x1.5W p = 0.88Wp a p = 1.00 R p = 2.50 Table , ASCE 7-10 At any level of floor or roof level of the building (F p ) = 0.4x1.0x1.95x(1+2(1.0) (2.5/1.5) = 1.40W p Use Fp = 1.40 Wp 0.88 W p 4.68 W p Transverse load on wall (F p )ASD = 1.40 x 8 psf /1.4 = 8.0 psf Use 8 psf 5 psf (see A1, page 1) Seismic Load (ASD) Governs 10 psf (see A4, page 1) For Serviceability, Gypsum Wallboard finish is classified as flexible finish, per Section (Table ) of 2012 IBC, deflection limit = L/120. Using Interior Non-Structural Non-Composite, Wall Height Tables, Steel Stud Manufacturers Association, ICBO ER-4943P*, Product Technical Information, following is stud size and spacing: * Note that this Product Technical Information does not comply with 2012 IBC. 362S 16" o.c.: Limiting Wall Height = 15'-11" (for 7.5 psf) Limiting Wall Height = 13'-10" (for 10 psf) For Partition Wall Height = 14'-0" and 8 psf; USE 362S (F y = 33 ksi; F u = 45 16" o.c. C - Tranverse (out-of-plane) Loads to the CFS Anchorage Calculation of shear load to CFS anchorage Shear load (ASD) to CFS anchorage at top or bottom of wall = (1.40/1.4) x 8 lbs/ft x 14.0'/2 = 56 lbs / ft

63 3 of 4 D - Allowable Service Load for Fasteners Driven into Steel and Concrete 9/4/ Allowable Service Loads for fastener driven into steel: 3/16" thick steel (support thickness), ASTM A36 Using Hilti Universal Knurled Shank fastener X-U, Shank Diameter d = 0.157" Allowable Shear Load = 720 lbs (Table 2, ICC-ES, ESR-2269) 2. Allowable Service Loads for fastener driven into concrete: 4" thick (support thickness) normal-weight concrete, f'c = 2500 psi Using Hilti Universal Knurled Shank fastener X-U, Shank Diameter d = 0.157" For minimum embedment = 1" < 4"/3 = 1.33" (Max. Embed) Allowable Shear Load = 190 lbs (Table 3, ICC-ES, ESR-2269) 3. Allowable Service Loads for fastener "Limited by Tilting and Bearing", Section E4.3.1, AISI S100: CFS runner (track) 27 mils (design thickness = ") F y = 33 ksi ; F u = 45 ksi Using Hilti Universal Knurled Shank fastener X-U, Shank Diameter d = 0.157" Allowable Shear Load = (2.7 x t 1 x d x F u1 )/Ω ; Ω = 3.0 (Eq. E ) (t 2 /t 1 2.5) = (2.7 x x 0.157" x psi )/3.0 Allowable Shear Load = 180 lbs Case 1, Structural Steel Support, 3/16" thick steel, ASTM A36 Allowable Shear Load = 180 lbs, item 3 above governs Anchorage at top and bottom of wall: Fastener spacing = (180 lb/ft / 56 lb/ft)x12 = 38.6" Use Hilti Universal Shank Fastener X-U at 36" o.c. (ICC-ES ESR-2269) Case 2, 4" thick, normal-weight Concrete, f'c = 2500 psi Allowable Shear Load = 180 lbs, item 3 above governs Anchorage at top and bottom of wall: Fastener spacing = (180 lb/ft / 56 lb/ft)x12 = 38.6" * Spacing of power driven fasteners (Fastening of runner to concrete slabs) not to exceed 24" o.c. per Section of ASTM C754. Use Hilti Universal Shank Fastener X-U (Min. Embed = 1") at 24" o.c.* (ICC-ES ESR-2269)

64 4 of 4 Codes and Reference Standards: 9/4/ International Building Code (IBC), International Code Council. 2. ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers. 3. AISI S100, North American Specification for Design of Cold-Formed Steel Structural Members, AISI S200, North American Standard for Cold-Formed Steel Framing - General Provisions, Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products (ASTM C754).

65 1 of 4 Design Example 2 - Partial Height Partition Wall 9/4/2012 CFS Interior Nonstructural Walls - Using Power Driven Fasteners Outline This example will illustrate the following parts of the design process A. Transverse (out-of-plane) loads on interior nonstructural walls B. Design of CFS stud size and spacing C. Distribution of transverse (out-of-plane) loads to the CFS anchorage at bottom of wall only D. Allowable service load for fasteners driven into steel and concrete Given Information Five story Building, each story height = 15'-0" Average roof height of structure (h)= 75'-0" Interior Nonstructural Wall (Partial Height Partition Wall): Partition Wall above 4th floor, Height = 12'-0" 1/2" Gypsum Wallboard each side Dead Load of Interior Nonstructural Wall (Table C3-1, ASCE 7-10) = 8 psf Ceiling: Partition that are tied to the ceiling shall be laterally braced to the building structure per Section of ASCE This example assumes ceiling lateral load is transferred by the brace above to the building structure CFS stud and runner (track)material strength: F y = 33 ksi ; F u = 45 ksi Power Driven Fasteners fastening to: Case 1, Structural Steel Support, 3/16" thick steel, ASTM A36 Case 2, 4" thick, normal-weight Concrete, f'c = 2500 psi Code Level Seismic Design Lateral Load Criteria: I p (Component Importance factor per Section , ASCE 7-10) = 1.0 S DS (Spectral acceleration, short period) = 1.25 A - Transverse (out-of-plane) Loads on Interior Nonstructural Walls 1. Interior walls and partitions that exceed 6'-0" in height,--- shall have adequate strength to resist the loads to which they are subjected to but not less than a horizontal load of 5 psf, per Section of 2012 IBC. 2. For all Seimic Design Categories (A, B, C, D, E and F) Seismic Design Force shall be calculated per Section of ASCE Partitions that are tied to the ceiling and all partitions greater than 6 ft in height shall be laterally braced---. Bracing shall be spaced to limit horizontal deflection---. EXCEPTION: , 3. The partitition horizontal seismic load does not exceed 5 psf, per Section of ASCE Maximum transverse (out-of-plane) load is limited to 10 psf for Non-Structural member, per Section A2, Definitions of AISI S200. Generally ASD seismic transverse loads (0.7E) calculated per A2 above are less than 5psf, thus minimum transverse load of 5 psf specified per A1 above governs. Note that 10 psf limit specified in A4 above is not a minimum transverse load for the design of non-structural member.

66 2 of 4 B - Design of CFS stud size and spacing 9/4/ Seismic Design Force: F p = 0.4 a p S DS W p (1 + 2 (z/h)) (R p /I p ) (13.3-1) F p 1.6S DS I p W p (13.3-2) = 1.6x1.25x1.0W p = 2.00W p F p 0.3S DS I p W p (13.3-3) = 0.3x1.25x1.0W p = 0.38Wp a p = 1.00 R p = 2.50 Table , ASCE 7-10 At fourth floor base, z = 60.0' (F p ) = 0.4x1.0x1.25x(1+2(60.0/75.0) (2.5/1.0) = 0.52W p Use Fp = 0.52 Wp At top of partition wall, z = 72.0' (F p ) = 0.4x1.0x1.25x(1+2(72.0/75.0) (2.5/1.0) = 0.58W p Use Fp = 0.58 Wp Transverse load on wall (F p )ASD = 0.5( )8 psf /1.4 = 3.1 psf Use 5.0 psf 5 psf (see A1, page 1) For Serviceability, Gypsum Wallboard finish is classified as flexible finish, per Section (Table ) of 2012 IBC, deflection limit = L/120. Using Interior Non-Structural Non-Composite, Wall Height Tables, Steel Stud Manufacturers Association, ICBO ER-4943P*, Product Technical Information, following is stud size and spacing: * Note that this Product Technical Information does not comply with 2012 IBC. 250S 16" o.c.: Limiting Wall Height = 12'-0" (for 5.0 psf) USE 250S (F y = 33 ksi; F u = 45 16" o.c. C - Tranverse (out-of-plane) Loads to the CFS Anchorage Calculation of shear load to CFS anchorage Shear load (ASD) to CFS anchorage at bottom of wall = (0.52/1.4) x 8 lbs/ft x 12.0'/2 = 18 lbs / ft Shear load (ASD) to CFS anchorage at bottom of wall = 5 psf x 12.0'/2 = 30 lbs / ft Governs

67 3 of 4 D - Allowable Service Load for Fasteners Driven into Steel and Concrete 9/4/ Allowable Service Loads for fastener driven into steel: 3/16" thick steel (support thickness), ASTM A36 Using Hilti Universal Knurled Shank fastener X-U, Shank Diameter d = 0.157" Allowable Shear Load = 720 lbs (Table 2, ICC-ES, ESR-2269) 2. Allowable Service Loads for fastener driven into concrete: 4" thick (support thickness) normal-weight concrete, f'c = 2500 psi Using Hilti Universal Knurled Shank fastener X-U, Shank Diameter d = 0.157" For minimum embedment = 1" < 4"/3 = 1.33" (Max. Embed) Allowable Shear Load = 190 lbs (Table 3, ICC-ES, ESR-2269) 3. Allowable Service Loads for fastener "Limited by Tilting and Bearing", Section E4.3.1, AISI S100: CFS runner (track) 18 mils (design thickness = ") F y = 33 ksi ; F u = 45 ksi Using Hilti Universal Knurled Shank fastener X-U, Shank Diameter d = 0.157" Allowable Shear Load = (2.7 x t 1 x d x F u1 )/Ω ; Ω = 3.0 (Eq. E ) (t 2 /t 1 2.5) = (2.7 x x 0.157" x psi )/3.0 Allowable Shear Load = 120 lbs Case 1, Structural Steel Support, 3/16" thick steel, ASTM A36 Allowable Shear Load = 120 lbs, item 3 above governs Anchorage at bottom of wall: Fastener spacing = (120 lb/ft / 30 lb/ft)x12 = 48.0" Use Hilti Universal Shank Fastener X-U at 48" o.c. (ICC-ES ESR-2269) Case 2, 4" thick, normal-weight Concrete, f'c = 2500 psi Allowable Shear Load = 120 lbs, item 3 above governs Anchorage at bottom of wall: Fastener spacing = (120 lb/ft / 30 lb/ft)x12 = 48.0" * Spacing of power driven fasteners (Fastening of runner to concrete slabs) not to exceed 24" o.c. per Section of ASTM C754. Use Hilti Universal Shank Fastener X-U (Min. Embed = 1") at 24" o.c.* (ICC-ES ESR-2269)

68 4 of 4 Codes and Reference Standards: 9/4/ International Building Code (IBC), International Code Council. 2. ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers. 3. AISI S100, North American Specification for Design of Cold-Formed Steel Structural Members, AISI S200, North American Standard for Cold-Formed Steel Framing - General Provisions, Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products (ASTM C754).

69 1 of 2 Design Example 3 9/4/2012 Based on OSHPD Preapproved Details (OPD) CBC Standard Partition Wall Details CFS Interior Nonstructural Walls - Using Power Driven Fasteners Outline This example will illustrate the following: A. Transverse (out-of-plane) loads on interior nonstructural walls Given Information* * From Reference 1 Partition Wall Height = 9'-0" to 16'-0" Interior Nonstructural Wall (Full Height Partition Wall): Two layers of Gyp Board on one side or one layer of Gyp Board on both sides Dead Load of Interior Nonstructural Wall = 7.5 psf (See General Notes 7C, sheet ST0.01) Seismic Coefficients (See General Notes 7D, sheet ST0.02): a p = 1.0 R p = 2.5 I p (Component Importance factor) = 1.5 S DS (Spectral acceleration 0.25 to 1.95, use 1.95) = 1.95 z/h = 1.0 (Value 1.0 allows for installation at any floor or roof level of the building) A - Transverse (out-of-plane) Loads on Interior Nonstructural Walls 1. Interior walls and partitions that exceed 6'-0" in height,--- shall have adequate strength to resist the loads to which they are subjected to but not less than a horizontal load of 5 psf, per Section 1607A.13 of 2010 CBC. 2. For all Seimic Design Categories (A, B, C, D, E and F) Seismic Design Force shall be calculated per Section of ASCE Maximum transverse (out-of-plane) load is limited to 10 psf for Non-Structural member, per Section A2, Definitions of AISI S200. Seismic Design Force: F p = 0.4 a p S DS W p (1 + 2 (z/h)) (R p /I p ) (13.3-1) F p 1.6S DS I p W p (13.3-2) = 1.6x1.95x1.5W p = 4.68W p F p 0.3S DS I p W p (13.3-3) = 0.3x1.95x1.5W p = 0.88Wp (F p ) = 0.4x1.0x1.95x(1+2(1.0) (2.5/1.5) = 1.40W p Use Fp = 1.40 Wp 0.88 W p 4.68 W p Transverse load on wall (F p )ASD = 1.40 x 7.5 psf /1.4 = 7.5 psf 5 psf (see A1, page 1) Seismic Load (ASD) Governs 10 psf (see A4, page 1)

70 Codes and Reference Standards: 2 of 2 9/4/ California Building Code (Based on 2009 International Building Code). 2. ASCE/SEI 7-05, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers. References: 1. OSHPD Preapproved Details (OPD) CBC Standard Partition Wall Details.

71 AC R1 #12

72 AC R1 #12 September 11, 2012 Mr. Brian Gerber, S.E. Principal Structural Engineer ICC Evaluation Services, LLC Workman Mill Road Whittier, CA RE: Proposed Revisions to the Acceptance Criteria for Fasteners Power-driven into Concrete, Steel, and Masonry Elements, Subject AC R1 Dear Mr. Gerber, We have reviewed the changes to AC70 that have been suggested and provide the following comments. Item #3 Please clarify whether the 1/8 inch minimum thickness limitation proposed is also applicable to Section where the minimum thickness is listed as 3/16 inch. Item #4 While we understand the changes proposed to reflect Section of ASCE 7, we recommend language be added to clarify that the use of fastener in steel material to resist seismic load of up to 250 pounds is for connection of a nonstructural component. The language may be suggested as follows: In steel base materials when used for non-structural applications where the service load on any individual fasteners does not exceed the lesser of 250 pounds (1112 N) or the published allowable load. Item #5 Please clarify whether the minimum thickness limitation for steel listed in Section 1.2 is applicable to metals other than steel. While we do not object to adding metals other than steel to AC70, it may be appropriate to discuss the issue of galvanic corrosion of dis-similar metals. Thank you for consideration of these comments. Should you have any questions, please do not hesitate to contact me. Sincerely, Ken Cho, P.E. Engineer kcho@strongtie.com Simpson Strong-Tie Company Inc W. Las Positas Boulevard Pleasanton, CA Phone: Fax:

73 AC R1 #12

74 AC R1 #12

75

76

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures Structural vs Nonstructural Members Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures Behavior of Cold-Formed Steel Members STEEL DESIGN SPECIFICATIONS Type of steel Specification

More information

Report No Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015

Report No Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015 EVALUATION SUBJECT: ProX HEADER SYSTEM Report No. 0286 Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015 REPORT HOLDER: BRADY INNOVATIONS, LLC 2934-1/2 BEVERLY GLEN CIRCLE, SUITE 427

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3145 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 05 00 00 METALS SECTION:

More information

Design of Nonstructural Members in Accordance with AISI S220

Design of Nonstructural Members in Accordance with AISI S220 Twenty-First International Specialty Conference on Cold-Formed Steel Structures St. Louis, Missouri, USA, October 24 & 25, 2012 Design of Nonstructural Members in Accordance with AISI S220 R.A. LaBoube

More information

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design BRADY INNOVATIONS, LLC. PROX HEADER SYSTEM CSI Section: 05 05 23 Metal Fastenings 05 40 00 Cold-formed Metal Framing 1.0 RECOGNITION Brady Innovations, LLC s ProX Header System recognized in this report

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1663 Reissued 03/2017 This report is subject to renewal 03/2019. DIVISION: 03 00 00 CONCRETE

More information

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year. ESR- Reissued September, 00 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 0 Workman Mill Road, Whittier, California 900 #

More information

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019 EVALUATION SUBJECT: ALUR DIVIDING WALL REPORT HOLDER: Modular Architectural Interiors LLC dba MAI 330 Waterloo Valley Road Mount Olive, NJ 07828 Phone: (973) 446-2300 Fax: (973) 446-2399 www.maispace.com

More information

DECORATIVE INTERIOR WALL PANEL FACING SYSTEM

DECORATIVE INTERIOR WALL PANEL FACING SYSTEM DECORATIVE INTERIOR WALL PANEL FACING SYSTEM from WALL PANEL SYSTEMS, INC. (WPS) The wall panel system analyzed herein is comprised of colored and textured panels of homogenous phenolic composites. Panels

More information

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1530 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 03 00

More information

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years.

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years. ICC-ES Evaluation Report ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT PEDRO BIRBA VICE-PRESIDENT VAN AMBATIELOS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA MAYOR

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

2012 & 2015 International Building Code. Section Section Section Section Section Section 713.4

2012 & 2015 International Building Code. Section Section Section Section Section Section 713.4 Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated and has an Assembly Evaluation

More information

Manufacturing Facilities City of Industry, CA Denver, CO Ft. Worth, TX Pittsburg, CA PRO-X HEADER

Manufacturing Facilities City of Industry, CA Denver, CO Ft. Worth, TX Pittsburg, CA PRO-X HEADER Product Description Basic Use is a light gauge steel header that provides horizontal and vertical load support. This pre-engineered metal framing component is designed as a 1- or 2-piece steel header that

More information

2012 & 2015 International Building Code. Section Section Section 713.4

2012 & 2015 International Building Code. Section Section Section 713.4 Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated and has an Assembly Evaluation

More information

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3831 Reissued 12/2017 This report is subject to renewal 12/2018. SECTION: 09 29 00

More information

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018 HUBER ENGINEERED WOODS ZIP SYSTEM R-SHEATHING CSI Section: 06 12 00 Structural Panels 06 16 00 Sheathing 1.0 RECOGNITION ZIP System R-Sheathing panels, manufactured by Huber Engineered Woods, LLC, were

More information

Originally Issued: 07/29/2014 Revised: 07/31/2018 Valid Through: 07/31/2019

Originally Issued: 07/29/2014 Revised: 07/31/2018 Valid Through: 07/31/2019 SCAFCO STEEL STUD MANUFACTURING CO. PRICELESS HEADER AND KWIK-JAMB SYSTEM CSI Section: 05 40 00 Cold-Formed Metal Framing 1.0 RECOGNITION The Priceless Header and Kwik-Jamb System recognized in this report

More information

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3275 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 03 00

More information

STRUCTURAL CALCULATIONS EXTERIOR SIDING CLADDING SYSTEM FLUSH PANEL SIDING SYSTEM AND LAPPED PANEL SIDING SYSTEM

STRUCTURAL CALCULATIONS EXTERIOR SIDING CLADDING SYSTEM FLUSH PANEL SIDING SYSTEM AND LAPPED PANEL SIDING SYSTEM JN 3617 Page 1 of 27 NOTES ON ANALYSIS, DESIGN METHOD, BUILDING CODE REFERENCES, AND ASSUMPTIONS. The exterior phenolic panel siding system is classified under the International Building Code as a Non-

More information

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California Reissued June 1, 2002 ICBO Evaluation Service, Inc. 5360 Workman Mill Road, Whittier, California 90601 www.icboes.org Filing Category: DESIGN Concrete DURISOL WALL FORMS FOR CONCRETE CONSTRUCTION DURISOL

More information

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2047 Reissued 07/207 This report is subject to renewal 07/209. DIVISION: 05 00 00

More information

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 42-6587 (562) 699-054 www.icc-es.org Most Widely Accepted and Trusted ESR-66 Reissued 0/207 Revised 2/208 This report is subject to renewal 0/209. DIVISION:

More information

RCKW Kneewall Connectors

RCKW Kneewall Connectors This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. The Simpson Strong-Tie RCKW rigid connectors

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1042 Reissued February 1, 2011 This report is subject to renewal in two years. A Subsidiary of the International Code Council DIVISION:

More information

IAPMO ES. Cover Sheet. Evaluation Criteria of. COLD-FORMED STEEL or WOOD FRAMED / STEEL-SHEATHED SHEAR WALLS

IAPMO ES. Cover Sheet. Evaluation Criteria of. COLD-FORMED STEEL or WOOD FRAMED / STEEL-SHEATHED SHEAR WALLS IAPMO ES Cover Sheet Evaluation Criteria of COLD-FORMED STEEL or WOOD FRAMED / STEEL-SHEATHED SHEAR WALLS Posted for public commenting on 12/11/08 thru 1/14/09 Comments currently under review International

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3833 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 03 00

More information

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016. ICC-ES Evaluation Report ESR-894 Reissued April 04 This report is subject to renewal April, 0. www.icc-es.org (800) 4-87 () 99-04 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL

More information

SECTION NON--STRUCTURAL METAL FRAMING

SECTION NON--STRUCTURAL METAL FRAMING The Collective Voice of America s Steel Framing Industry The Steel Framing Industry Association (SFIA) is dedicated to expanding the market for cold-formed steel in construction through programs and initiatives

More information

TER No Cultured Stone & ProStone Applications Over Continuous Insulation

TER No Cultured Stone & ProStone Applications Over Continuous Insulation Cultured Stone & ProStone Applications Over Continuous Insulation TER No. 1302-01 Boral Stone Products LLC 200 Mansell Court East, Suite 310 Roswell, GA 30076 419-318-5345 949-341-8890 (fax) chris.hines@boral.com

More information

Panduit Corporation Tinley Park, Illinois. Outset and Inset Cabinets Seismic Load Rating and Anchorage Design

Panduit Corporation Tinley Park, Illinois. Outset and Inset Cabinets Seismic Load Rating and Anchorage Design Panduit Corporation Tinley Park, Illinois Outset and Inset Cabinets Seismic Load Rating and Anchorage Design February 13, 2013 Degenkolb Job Number B2439007.00 www.degenkolb.com 500 Degenkolb Engineers

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

ANALYSIS AND DESIGN OF MOMENT RESISTING MIDWALL BY THE STEEL NETWORK, INC.

ANALYSIS AND DESIGN OF MOMENT RESISTING MIDWALL BY THE STEEL NETWORK, INC. ANALYSIS AND DESIGN OF MOMENT RESISTING MIDWALL BY THE STEEL NETWORK, INC. Paul Lackey, P.E., Muhammad Ghoraba, Nabil A. Rahman, Ph.D., P.E. and Kurtis Kennedy MidWall is a hold-down product intended to

More information

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-2269 Reissued 02/2017 Revised 11/2018 This report is subject to renewal 02/2019.

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS 0 ICC-ES Report ICC-ES (800) 42-6587 (562) 699-054 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-45 Reissued 06/206 This report is subject to renewal 06/207 DIVISION: 0 00 00CONCRETE SECTION:

More information

where: P s = Applied service tension load, pounds (kg). P t V s V t

where: P s = Applied service tension load, pounds (kg). P t V s V t Æ Æ Æ Æ Æ Æ Æ Æ Æ ESR-1752 Most Widely Accepted and Trusted Page 2 of 7 3.1.7 X-S16P8TH: The X-S16P8TH fastener is a powder actuated fastener for installation into steel. It has a shank diameter of 0.145

More information

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017 Shaft Wall Solutions for Wood-Frame Structures Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017 Shaft Walls Shaft Walls Form Shaft Enclosures The purpose

More information

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015 0 ICC ES Report ICC ES (800) 42 6587 (562) 699 054 www.icc es.orgg 000 Most Widely Accepted and Trusted ESR 2269 Reissued 02/205 This report is subject to renewal 02/207. DIVISION: 0 00 00 CONCRETE SECTION:

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3336 Reissued 01/2015 This report is subject to renewal 01/2017. DIVISION: 09 00 00 FINISHES

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 42-6587 (562) 699-054 www.icc-es.org ESR-1752 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 0 00 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588 0 ICC ES Report ICC ES (800) 4 687 (6) 699 04 www.icc es.org 000 Most Widely Accepted and Trusted ESR 06 Valid: 0/ to 0/6 DIVISION: 04 00 00 MASONRY SECTION: 04 0 9.6 MASONRY ANCHORS REPORT HOLDER: SIMPSON

More information

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued) 2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1

More information

Originally Issued: 12/18/2015 Revised: 04/14/2017 Valid Through: 12/31/2017

Originally Issued: 12/18/2015 Revised: 04/14/2017 Valid Through: 12/31/2017 INTERMAT SURE-BOARD SERIES 200S STRUCTURAL PANELS CSI Section: 05160-Metal Framing Systems 1.0 RECOGNITION Intermat Sure-Board Series 200S Structural Panels have been evaluated as floor and roof sheathing

More information

FROM: PROPOSED SUBSTITUTION: Use HILTI X-U instead of fillet weld or arc spot puddle weld

FROM: PROPOSED SUBSTITUTION: Use HILTI X-U instead of fillet weld or arc spot puddle weld DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED SUBSTITUTION: Use

More information

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC.

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 43 6587 (56) 699 0543 www.icc es.org ESR 97 Reissued /7 This report is subject to renewal /8. DIVISION: 05 00 00 METALS SECTION:

More information

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-CW CEILING WIRE FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED SUBSTITUTION: Use

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2269 Reissued 02/2017 This report is subject to renewal 02/2019. DIVISION: 03 00

More information

Expanding Your Solutions. ProX Header Rough Opening System

Expanding Your Solutions. ProX Header Rough Opening System Expanding Your Solutions Rough Opening System Effective 10/18/2017 Table of Contents Introduction to... 1 Installation... 2 Outer Sectional Properties; Outer Allowable Values... 3 Combined Sectional Properties;

More information

Limi ng Heights for Nonstructural Standard and EQ Wall Studs

Limi ng Heights for Nonstructural Standard and EQ Wall Studs TECH NOTE Publication 1, Version 1 March 2018 Limi ng Heights for Nonstructural Standard and EQ Wall Studs SUMMARY: This Technical Note addresses cold-formed steel studs in nonstructural interior wall

More information

REPORT HOLDER: OLMAR SUPPLY INC RESEARCH DRIVE LIVERMORE, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: OLMAR SUPPLY INC RESEARCH DRIVE LIVERMORE, CALIFORNIA EVALUATION SUBJECT: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3503 Reissued 03/2016 This report is subject to renewal 03/2017. DIVISION: 05 00 00 METALS SECTION:

More information

research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-2

research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-2 research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-005 REVISION 006 American Iron and Steel Institute Cold-Formed

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006

More information

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ESR 2562 Reissued 08/206 This report is subject to renewal 08/208. DIVISION: 07 00 00

More information

CTLGroup Report No

CTLGroup Report No Report for DMFCWBS, LLC CTLGroup Report No. 055022 Limiting Heights of Composite Wall Assemblies Composed of Cold-Formed Steel Studs Sheathed with 5/8-in. USG Sheetrock Brand Firecode Type X Gypsum Panels

More information

Masonry Veneer - Chapter 6. Masonry Veneer Anchored Veneer

Masonry Veneer - Chapter 6. Masonry Veneer Anchored Veneer Masonry Veneer - Chapter 6 Chapter 6 covers anchored and adhered veneer. Following are prescriptive requirements for areas with wind 110 mph Vertical support of masonry veneer Support: Noncombustible structural

More information

(800) (562) A Subsidiary of the International Code Council

(800) (562) A Subsidiary of the International Code Council ICC-ES Evaluation Report ESR-2089 Reissued September 2014 This report is subject to renewal September 2016. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

CTLGroup Report No A

CTLGroup Report No A Report for DMFCWBS, LLC CTLGroup Report No. 055016A Limiting Heights of Composite Wall Assemblies Composed of Cold-Formed Steel Studs Sheathed with 1/2-in. Generic Gypsum Board for Interior Non-Load Bearing

More information

Originally Issued: 05/06/2010 Revised: 05/31/2018 Valid Through: 05/31/2019

Originally Issued: 05/06/2010 Revised: 05/31/2018 Valid Through: 05/31/2019 EVALUATION SUBJECT: TONGUE & GROOVE (T-G) & SHIP LAP (S-L) PANELS REPORT HOLDER: ThermaSteel Inc. 609 West Rock Road Radford, Virginia 24141 CSI Division: 07-THERMAL AND MOISTURE PROTECTION CSI Section:

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS SEPAND SAMZADEH CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR DEPARTMENT

More information

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Charlotte WSF, November 2, 2017

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Charlotte WSF, November 2, 2017 Shaft Wall Solutions for Wood-Frame Structures Ricky McLain, PE, SE WoodWorks Wood Products Council Charlotte WSF, November 2, 2017 Course Description It is fairly common for light wood-frame commercial

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR THE TESTING AND ANALYSIS OF STEEL SHEET SHEATHING FOR WOOD AND COLD FORMED STEEL LIGHT

More information

Stanley Fastening Systems, L.P. Stanley BOSTITCH Pneumatic Pins. TER No

Stanley Fastening Systems, L.P. Stanley BOSTITCH Pneumatic Pins. TER No Stanley Fastening Systems, L.P. TER No. 1109-02 StanleyBlack&Decker, Inc. StanleyBlack&Decker, Inc. Stanley Fastening Systems, L.P. 125 Circuit Drive North Kingstown, Rhode Island 02852 888-556-6696 bostitch.com

More information

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15. The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15. Please refer to the publication in its entirety for complete details on this product

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3251 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 03 00

More information

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Wall Framing Released September 20, 2010 Updated December 4, 2012 Note: Tables for cladding attachments to wood framing have

More information

June 1, 2012 PARTIES INTERESTED IN COLD-FORMED STEEL FRAMING MEMBERS

June 1, 2012 PARTIES INTERESTED IN COLD-FORMED STEEL FRAMING MEMBERS June 1, 2012 TO: PARTIES INTERESTED IN COLD-FORMED STEEL FRAMING MEMBERS SUBJECT: Proposed Revisions to the Acceptance Criteria for Cold-formed Steel Framing Members, Subject AC46-0612-R1 (WM/DM) Dear

More information

TECHNICAL NOTE On Cold-Formed Steel Construction

TECHNICAL NOTE On Cold-Formed Steel Construction TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 Washington, DC 20005 (202) 785-2022 $5.00 Changes from the 1997 UBC to the 2006 IBC for Lateral Design with Cold-Formed

More information

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

R CODE CHANGE PROPOSAL FORM (See instructions on page 2) CODE CHANGE PROPOSAL FORM (See instructions on page 2) Code: IRC 12/13 Sections 301.2.2.2.1 Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee 1. Delete as shown

More information

August 1, 2018 PARTIES INTERESTED IN PREFABRICATED, COLD-FORMED STEEL, LATERAL-FORCE-RESISTING VERTICAL ASSEMBLIES

August 1, 2018 PARTIES INTERESTED IN PREFABRICATED, COLD-FORMED STEEL, LATERAL-FORCE-RESISTING VERTICAL ASSEMBLIES August 1, 2018 TO: PARTIES INTERESTED IN PREFABRICATED, COLD-FORMED STEEL, LATERAL-FORCE-RESISTING VERTICAL ASSEMBLIES SUBJECT: Proposed Revisions to the Acceptance Criteria for Prefabricated, Cold- Formed

More information

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 2-6587 (562) 699-05 www.icc-es.org ESR-787 Issued 07/2017 This report is subject to renewal 07/2018. DIVISION: 05 00 00 METALS

More information

SECTION NON-STRUCTURAL SEISMIC DESIGN CRITERIA PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION NON-STRUCTURAL SEISMIC DESIGN CRITERIA PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 014100 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

TER No Attachment of Exterior Wall Coverings Through Kingspan Kooltherm Insulation Boards to Wood or Steel Wall Framing

TER No Attachment of Exterior Wall Coverings Through Kingspan Kooltherm Insulation Boards to Wood or Steel Wall Framing Attachment of Exterior Wall Coverings Through Kingspan Kooltherm Insulation Boards to Wood or Wall Framing Kingspan Insulation LLC 2100 RiverEdge Parkway Suite 175 Atlanta, GA 30328 kingspaninsulation.us

More information

REPORT HOLDER: MITEK USA, INC. EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2089 Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 05 00

More information

Patio Cover Manufacturers and other Interested Parties

Patio Cover Manufacturers and other Interested Parties To: From: Patio Cover Manufacturers and other Interested Parties ICC-ES Date: February 6, 2009 Subject: Technical Review of Patio Cover Engineering Analysis in Accordance for Patio Covers (AC340) MEMO

More information

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3336 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 09 00

More information

PRICELESS HEADER & KWIK-JAMB SYSTEM IAPMO UNIFORM ER 0342

PRICELESS HEADER & KWIK-JAMB SYSTEM IAPMO UNIFORM ER 0342 PRICELESS HEADER & KWIK-JAMB SYSTEM 2015 MILL CERTIFIED 100% GALVANIZED www.scafco.com IAPMO UNIFORM ER 0342 Table of Contents Product Application 4 Features and Benefits 4 Order Information 4 Certification

More information

Building Division Informational Handout

Building Division Informational Handout CITY OF SAN JOSÉ, CALIFORNIA Building Division Informational Handout Conventional Light Frame Construction Design Provisions 2007 CBC Handout No. 2-21 Published: 1/1/08 Page 1 of 3 This document summarizes

More information

Code Compliance Research Report CCRR-0205

Code Compliance Research Report CCRR-0205 Code Compliance Research Report CCRR-0205 Issue Date: 06-30-2017 Renewal Date: 06-11-2018 DIVISION: 05 00 00 - METALS Section: 05 40 00 Cold-Formed Metal Framing Section: 05 41 00 Structural Metal Stud

More information

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3009 Reissued 02/2018 This report is subject to renewal 02/2020. SECTION: 03 16 00

More information

REPORT HOLDER: WARE INDUSTRIES, INC. (DBA Marino\WARE) 400 METUCHEN ROAD SOUTH PLAINFIELD, NEW JERSEY EVALUATION SUBJECT:

REPORT HOLDER: WARE INDUSTRIES, INC. (DBA Marino\WARE) 400 METUCHEN ROAD SOUTH PLAINFIELD, NEW JERSEY EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2620 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 05 00

More information

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE ICC EVALUATION SERVICE, INC. Evaluate P Inform P Protect ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) AC191 Approved May 2008 Effective June 1, 2008 Previously approved February 2008, October 2007,

More information

FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST

FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHEAR WALL PANELS REPORT HOLDER: SIMPSON STRONG-TIE COMPANY INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHEAR WALL PANELS REPORT HOLDER: SIMPSON STRONG-TIE COMPANY INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2652 Reissued 04/2018 This report is subject to renewal 04/2019. DIVISION: 06 00

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS GEORGE HOVAGUIMIAN CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015.

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 4-6587 (56) 699-054 ESR-06 Reissued May, 0 This report is subject to renewal June, 05. A Subsidiary of the International Code Council DIVISION: 0 00 00 CONCRETE

More information

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3788 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 04 00

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

BEARING METAL STUD FRAMING

BEARING METAL STUD FRAMING L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or

More information

*Corrected October 2005

*Corrected October 2005 ESR-1056* Reissued December 1, 2004 This report is subject to re-examination in two years. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

ESR ICC Evaluation Service, Inc. Issued March 1, 2006 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Issued March 1, 2006 This report is subject to re-examination in one year. ESR-1328 Issued March 1, 2006 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) Plan Check Engineer:

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

CALIFORNIA ERIC GARCETTI MAYOR

CALIFORNIA ERIC GARCETTI MAYOR BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS GEORGE HOVAGUIMIAN CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code. LEGACY REPORT ER-2895 Reissued March 1, 2004 www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional Office 900 Montclair Road, Suite A, Birmingham,

More information

Versetta Stone Panelized Stone Veneer Applications Over Continuous Insulation. TER No Boral Stone Products LLC

Versetta Stone Panelized Stone Veneer Applications Over Continuous Insulation. TER No Boral Stone Products LLC Applications Over Continuous Insulation TER No. 1212-01 Boral Stone Products LLC 200 Mansell Court East, Suite 310 Roswell, GA 30076 419-318-5345 949-341-8890 (fax) chris.hines@boral.com versettastone.com

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR ANCHORED MASONRY VENEER SYSTEM WITH POLYSTYRENE FOAM PLASTIC BACKING EC 021-2014 (Adopted

More information