Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts
|
|
- Josephine King
- 6 years ago
- Views:
Transcription
1 Commonwealth of Massachusetts State Building Code 780-CMR 9 th Edition Renovation of Existing Buildings Using The International Existing Building Code IEBC 2015 with Massachusetts Amendments Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts IEBC 2015 Massachusetts Amendments As of this presentation, the 9 th Edition has not yet been adopted. As of January 12, 2016 the BBRS approved a draft. It is now up to the Executive Office of Administration and Finance to review the document. Following that a public hearing will be held and revisions could come before adoption. 1
2 IEBC 2015 Proposed Massachusetts Amendments 1. Chapter 34 in the IBC 2015 is Deleted 2. Investigation by a Registered Design Professional is mandatory for all renovations and additions to existing buildings including structural and non-structural systems 3. A table of Seismic Design and Analysis Coefficients Unique to Massachusetts 4. Miscellaneous changes, deletions and additions. Alternate Approaches to Remodeling 1. The Prescriptive Compliance Method Chapter 4 2. The Work Area Compliance Method Chapters 5 through The Performance Compliance Method Chapter 14 Appendix A1 to A5 Guidelines for Seismic Retrofit of Existing Buildings 2
3 Alternate No. 1 Chapter 4 Prescriptive Compliance Method Prerequisite An Investigation, Evaluation and report by Registered Design Professionals Shall be required As a condition of issuance of a Building Permit. Shall include structural, means of egress, fire protection, energy, etc. Evaluation and Design shall meet the requirements of (See MA Amendments) Alternate No. 1 Chapter 4 Prescriptive Compliance Method Continued Alterations and Additions Gravity Load Elements Must be strengthened unless the increase in load is less than 5%. Note : The cumulative effect of load increases since original construction shall be Considered. If the live load capacity is less than required by the IBC the area in question shall be posted. 3
4 Alternate No. 1 Chapter 4 Prescriptive Compliance Method Continued Alterations and Additions Lateral Load Resisting Systems All such systems shall be shown to meet IBC Sections 1609 (wind loads) & 1613 (Seismic) unless an increase in Demand/Capacity Ratio is less than 10% Additions can be vertical in which case the lateral system might have to be radically modified. Additions can also be lateral in which case they could be isolated from the original building. Alternate No. 1 Chapter 4 Prescriptive Compliance Method Continued Repairs Where damage has been done to a building s structural components an evaluation shall be done by a Structural Engineer. Repairs must meet the following requirements: 1. Full IBC wind load requirements must be met % of IBC Seismic Requirements must be met. 3. Full IBC Gravity Requirements must be met. Exception If damage is found to be less than substantial repairs may restore the members to pre-damage strengths. 4
5 Alternate No. 1 Chapter 4 Prescriptive Compliance Method Continued Change of Occupancy An increase to a higher occupancy category shall trigger an upgrade to full IBC Seismic resistance for the structure. 1. A structure that by analysis meets these requirements will not require reinforcement. 2. A structure that does not meet these requirements must be reinforced. 3. It should be noted that this change could trigger a seismic upgrade although the structure itself has not been modified Classification of work Repairs, Chapter 6 As defined in Chapter 2 do not include structural repairs. Alterations, Level 1 Shall comply with Chapter 7 (Non-Structural) Where alterations generally do not effect the structure the structural investigation and analysis report must be submitted to prove it. 1. Exceptions: Replacement of roofing and/or Equipment 2. All increases in dead load to roofs of more than 5% will require structural reinforcement. 3. Anchorage of Parapets in unreinforced masonry buildings will be required when the entire roof is removedd. 4. Roof Diaphragm must be investigated if the entire roof is replaced in buildings in areas of 115 mph wind speed and Type IV Essential Facilities. 5
6 Alterations Level 2 Chapters 7 & The level of alteration in this level of work obtains when the area of work is less than 50% of the existing building floor area. Gravity Load Resisting Elements Shall be reinforced unless an increase in load does not exceed 5%. Lateral Load Resisting Elements Shall be reinforced unless an increase in load does not exceed 10%. Alterations Level 3 Chapter 7,8 & The level of alteration in this level of work obtains when the area of work is more than 50% of the existing building floor area. Gravity Load Resisting Elements Shall be reinforced unless an increase in load does not exceed 5%. New elements shall comply with IBC requirements. Lateral Load Resisting Elements Shall meet the IBC requirements for full wind loading and for a reduced seismic loading in conformance with Section
7 Change of Occupancy Chapter Gravity Load Resisting Elements Shall be reinforced unless an increase in load does not exceed 5%. New elements shall comply with IBC requirements Lateral Load Resisting Elements Shall meet the IBC requirements for full wind loading and seismic loading where new occupancy is more than 10% of Building Area. Seismic detailing requirements may be waived. Unreinforced masonry bearing wall buildings may come under Appendix A1 for strengthening. Additions Chapter Gravity Load Resisting Elements Shall be reinforced unless an increase in load does not exceed 5%. New elements shall comply with IBC requirements. Group R (residential structures) are exempt where there are no more than 5 units. 7
8 Additions Chapter 11 continued Lateral Load Resisting System 1. Vertical Additions 1. Shall comply with IBC Wind Provisions. 2. Shall comply with Seismic Provisions Section (using 100% of prescribed forces). Reference to ASCE Shall comply with reduced seismic force levels per Section as defined in ASCE 41. Additions Chapter 11 continued Lateral Load Resisting System 2. Horizontal Additions 1. Shall comply with IBC Wind Provisions. 2. Shall comply with Seismic Provisions Section Irregularities shall be taken into account. 3. Snow Drift Loads Structural elements subject to snow drift shall be upgraded accordingly if increase is more than 5%. Except Group R buildings with less than 5 units. 8
9 Historic Buildings Chapter 12 Re: Massachusetts Historic Commission 1. Compliance is not mandatory. 2. Building is subject to Proof of Historic Building Status. 3. Replacement components may be in kind. 4. A formal structural report is required. 5. If the structure is deemed unsafe it can be repaired so as to be safe. This work shall be done under Chapter 5, except: 1. Building Official may approve of Floor Load by Signage, Limits to Occupancy, Barriers, Etc. 2. House Museums are exempt from Wind & Seismic Provisions. Relocated or Moved Buildings Chapter Foundation shall meet IBC requirements. 2. Connections to the foundation shall meet IBC requirements. 3. Building shall meet IBC wind load provisions. Except One & Two Family dwellings with no change in structure or wind zones more than 10%. 4. Shall comply with snow load provisions unless change is less than 5% 5. Shall comply with seismic provisions. Except for One & Two Family dwellings and Category A & B design categories. 9
10 Chapter 13 Performance Compliance Method 1. An Investigation and Analysis Report must be submitted by a registered design professional as condition of issuance of a Building Permit setting out the parameters of the approach. 2. A Peer Review of the above must be submitted by an independent registered design professional as condition of issuance of a Building Permit. 3. Date of Original Construction is to be established and the Applicable Code in force at the time of construction if possible. 4. Structural Provisions must comply using Chapters 4 to Exception: Residential buildings 3 stories or less of light frame construction and 6 units or less shall be exempt from compliance with loads set out in chapter 16 Conflicts between 2015 Prescriptive and Work Area Provisions 10
11 Question Period After a period of questions, if time permits, the presenter offers an interesting slide show of his Top Ten Structural Picks These are the highlights of issues that he feels are of importance for the Building Officials in regard to Structural issues 11
City of Tacoma Planning and Development Services
City of Tacoma Planning and Development Services ORDINANCE NO. 28155 Adopt and Amend the City s Building Code; amending Title 2 of the Tacoma Municipal Code, implement the 2012 International Building,
More information101.1 Title. These regulations shall be known as the Existing Building Code of Massachusetts, hereinafter referred to as this code.
This file incorporates comment from numerous stakeholders and building officials, staff, two BBRS advisory committees (SAC and C34AC), and others into the original redline code proposal approved by the
More informationCODE ANALYSIS REPORT SECOND FLOOR
CODE ANALYSIS REPORT SECOND FLOOR 384 DWIGHT STREET HOLYOKE, MA Prepared by Dietz & Company Architects, Inc. 17 Hampden Street Springfield, MA March 2014 INTRODUCTION The following report is a preliminary
More informationCode Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)
Code Requirements for Existing Buildings R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com R.W. Sullivan Engineering (RWS) was established in 1945 and currently
More information780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
780 CMR: MASSACHUSETTS AMENDMENTS TO THE INTERNATIONAL EXISTING BUILDING CODE 2009 CHAPTER 34: EXISTING STRUCTURES 101.1 Replace as follows: 101.1 Title. These regulations shall be known as e Existing
More information2012 IEBC Fundamentals 12/11/2017. Copyright 2012 International Code Council 1
Overview 2012 IEBC Fundamentals The purpose of the IEBC is to encourage the use and re-use of existing buildings while requiring reasonable upgrades and improvements Based on the 2012 International Existing
More informationSeismic Design Requirements
City of Medford Municipal Code Chapter 9 Presented by the Building Safety Department THESE PROVISIONS PRESCRIBE THE DESIGN REQUIREMENTS OF EXISTING BUILDINGS UNDERGOING: CHANGE OF OCCUPANCY ADDITIONS ALTERATIONS
More informationTHE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:
ORDINANCE NO. An ordinance amending Sections 91.202, 91.3401, 91.3401.1,91.3405.2.1, 91.3405.2.2, 91.3405.2.3 and 91.3405.4 of Article I of Chapter IX of the Los Angeles Municipal Code to amend terms,
More information2015 International Existing Building Code Overview Based on the International Existing Building Code (IEBC )
Goal 2015 International Existing Building Code Overview Based on the International Existing Building Code (IEBC ) To identify and describe key provisions of the 2015 IEBC. 2015 IEBC Overview 3 Description
More informationPrescriptive and Engineered Design Provisions of the Massachusetts One- and Two-Family Dwelling Code
Prescriptive and Engineered Design Provisions of the Massachusetts One- and Two-Family Dwelling Code Released July 27, 2009 Introduction: Buildings in the United States are designed to withstand the loads
More informationCode Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)
Code Requirements for Existing Buildings R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com R.W. Sullivan Engineering (RWS) was established in 1945 and currently
More informationBuilding Code 8 th Edition
Massachusetts State Building Code 8 th Edition Kevin S. Hastings, P.E., LEED AP R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com RW R.W. Sullivan Engineering
More information05/16/2016 1:36:13 PM
1223 Mineral Spring Avenue North Providence, RI 02904 STRUCTURAL EXISTING CONDITIONS REPORT Prepared for: Jonathan Levi Architects 266 Beacon Street Boston, Massachusetts, 02116 May 16, 2016Draft WESTPORT,
More informationVirginia Existing Building Code
2015 Virginia Existing Building Code 2015 Virginia Existing Building Code First Printing: September 2018 ISBN: 978-1-60983-852-2 COPYRIGHT 2018 by INTERNATIONAL CODE COUNCIL, INC. ALL RIGHTS RESERVED.
More informationTHE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:
ORDINANCE NO. 184163 An ordinance amending Sections 91.202, 91.3401, 91.3401.1, 91.3405.2.1, 91.3405.2.2, 91.3405.2.3 and 91.3405.4 of Article I of Chapter IX of the Los Angeles Municipal Code to amend
More informationTable 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)
2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1
More information2015 IBC Chapters 1 and 35
Study Session 1 2015 IBC Chapters 1 and 35 Administration OBJECTIVE: To obtain an understanding of the administrative provisions of the International Building Code Ò (IBC Ò ), including the scope and purpose
More informationOrdinance No July 1, 2016
(Insert Facing Page 3 IRC) 2.02.540 Amendment to IRC Section R105.2 Work Exempt From Permit, Building and Electrical Sections. The following additional exception shall be added to R105.2 Building: Building:
More informationRESIDENTIAL SEISMIC RETROFITS
RESIDENTIAL Barry H. Welliver Structural Engineer BHW Engineers SEAU 6th Annual Education Conference Davis Conference Center - Layton, Utah February 21st, 2018 TOPICS Introduction to Seismic Retrofits
More informationSTRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Chapter 85 Effective: 01-01-2011 DOCUMENT NO.: P/BC 2011-110 Revised: Previously Issued As: P/BC 2002-110 STRUCTURAL DESIGN REQUIREMENTS
More informationAnalysis of Changes for the 5 th Edition (2014) of the Florida Codes
Analysis of Changes for the 5 th Edition (2014) of the Florida Codes Changes to the Florida Building Code, Existing Building This Analysis of Changes for the 5 th Edition (2014) of the Florida Codes is
More informationEmeryville's Seismic Hazard Mitigation Ordinance
Emeryville's Seismic Hazard Mitigation Ordinance THIS IS THE CITY OF EMERYVILLE'S SEISMIC HAZARD MITIGATION ORDINANCE PASSED IN 1995 TO AMEND AND CLARIFY AN EARLIER ORDINANCE PASSED IN 1990. THIS ORDINANCE
More informationPRESCRIPTIVE COMPLIANCE METHOD
CHAPTER 3 PRESCRIPTIVE COMPLIANCE METHOD [B] SECTION 301 GENERAL 301.1 Scope. The provisions of this chapter shall control the alteration, repair, addition and change of occupancy of existing structures,
More informationMandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC Division 93 Effective: 11/22/15 DOCUMENT NO.: P/BC 2014-137 Revised: 06/07/16 Previously Issued As: N/A Mandatory Wood Frame Soft-story
More informationIEBC INTERNATIONAL EXISTING BUILDING CODE
A MEMBER OF THE INTERNATIONAL CODE FAMILY IEBC INTERNATIONAL EXISTING BUILDING CODE Receive FREE updates, excerpts of code references, technical articles, and more when you register your code book. Go
More informationIEBC: How to Address Challenging Code Issues; and, Let s Find Answers
IEBC: How to Address Challenging Code Issues; and, Let s Find Answers Boston Society of Architects Codes Committee February 15, 2017 Presented by Doug Anderson 313 Congress Street Boston, MA 02210 617.330.9390
More informationR CODE CHANGE PROPOSAL FORM (See instructions on page 2)
CODE CHANGE PROPOSAL FORM (See instructions on page 2) Code: IRC 12/13 Sections 301.2.2.2.1 Proponent: Charles S. Bajnai, Chesterfield County, VA, ICC Building Code Action Committee 1. Delete as shown
More informationShayne O Manning, P.E., S.E., LEED AP 2017 OBC STRUCTURAL OVERVIEW
Shayne O Manning, P.E., S.E., LEED AP 2017 OBC STRUCTURAL OVERVIEW Presentation Synopsis The process by which the Ohio Board of Building Standards reviews the changes proposed by IBC code updates, both
More information780 CMR CHAPTER 34 EXISTING BUILDINGS STRUCTURES
780 CMR CHAPTER 34 EXISTING BUILDINGS STRUCTURES SECTION 3401 GENERAL 3401.1 Scope. Chapter 34 of the International Building Code 2009 is deleted in its entirety. The provisions of the International Existing
More informationA. Are Plan Reviews Important? B. Statement of Special Inspections C. Deferred Submittals D. DFCM Requirements
A. Are Plan Reviews Important? B. Statement of Special Inspections C. Deferred Submittals D. DFCM Requirements Is it okay to simply accept the engineer s stamp? Some key items to consider Life safety All
More informationAvailable at: Last Modified: December 2012
6.3 Architectural Components 6.3.7 Chimneys and Stacks 6.3.7.1 Unreinforced Masonry Chimney Unreinforced masonry (URM) chimneys are extremely vulnerable to earthquake damage; their behavior has long been
More informationFEMA P 50 & FEMA P 50 1
& Seismic Retrofit Guidelines for Detached, Single Family, Wood Frame Dwellings FEMA P 50 & FEMA P 50 1 & Seismic Retrofit Guidelines for Detached, Single Family, Wood Frame Dwellings FEMA P 50 1 & Seismic
More informationPractice Points NUMBER
Practice Points NUMBER 17 BUILDING CODES A Road Map to Structural Alterations in the International Existing Building Code LORI FERRISS AND MICHAEL J. AUREN In a climate of constantly evolving building
More informationCTC MEETING #25 CHILD WINDOW SAFETY REPORT
CTC MEETING #25 CHILD WINDOW SAFETY REPORT The Child Window Safety SG has not met following the 2012 Final Action Hearing. Group B activities did not necessitate SG meetings as the activity will be limited
More informationROOME & GUARRACINO, LLC Consulting Structural Engineers 48 Grove Street Somerville, MA Tel: Fax:
ROOME & GUARRACINO, LLC Consulting Structural Engineers 48 Grove Street Somerville, MA 02144 Tel: 617.628.1700 Fax: 617.628.1711 March 3, 2016 Mr. Jeff Hoover, Principal Tappe Architects, 6 Edgerly Place
More informationCALIFORNIA BUILDING AND SAFETY COMMISSIONERS. nmi 'DEI ERIC GARCETTI MAYOR PROPOSED SUBSTANTIAL STRUCTURAL DAMAGE ORDINANCE- COUNCIL FILE
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS INTERIM PRESIDENT E, FELICIA BRANNON JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ City of Los Angeles CALIFORNIA nmi 'DEI ERIC GARCETTI
More informationIndividual Truss Marking Is it a Building Code Requirement?
Introduction: Individual Truss Marking Is it a Building Code Requirement? Released April 1, 2010 On January 1, 2008, the 2007 edition of the California Building Code (CBC) 1 was adopted for use and replaced
More informationREINFORCING TABLES INSTALLATION MANUAL
REINFORCING TABLES 201 REINFORCING TABLES Design Limitations Introduction The structural wall reinforcing and lintel design tables contained within the Appendix of NUDURA s Installation Manual have been
More informationCode Requirement for Solar Photovoltaic (PV) Systems - General
City/County of [NAME OF CITY] Department of [NAME OF DEPARTMENT] TOOLKIT DOCUMENT City/County of [NAME OF CITY] Department of [NAME OF DEPARTMENT] Code Requirement for Solar Photovoltaic (PV) Systems -
More informationSimplified Seismic Assessment & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & FEMA P-50-1
& Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & FEMA P-50-1 & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & Seismic
More informationNC 22, , 2011 NC 2015 NC
1 History NC Building Code Council approved an Ad-Hoc August 22, 2011 Ad-Hoc Committee Started work October 26, 2011 NC Building Code Council approved the 2015 NC Existing Building Code December 11, 2013.
More information2012 International Existing Building Code. Jim Tinner, Building Official City of Bellingham May 15, 2013
2012 International Existing Building Code Jim Tinner, Building Official City of Bellingham May 15, 2013 Adopted by State Law IEBC is referenced by the International Building Code. Does not apply to single-family
More informationEFFECTIVE USE OF THE IBC/CBC
Distilling the code review process down to a methodical, sequential list of considerations is generally problematic. In many cases, related provisions from various chapters of the code must be considered
More informationINTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004
CITY OF MERCER ISLAND 9611 SE 36 th Street, Mercer Island, Washington 98040-3732 PHONE (206) 236-5300 FAX (206) 236-3645 TDD (206) 232-9598 www.ci.mercer-island.wa.us INTERNATIONAL BUILDING CODE - ADOPTION
More informationStructural Engineering
Structural Engineering 4 4.0 TABLE OF CONTENTS 4.1 General Approach 115 Submission Requirements 4.2 Codes and Standards 116 Structural Design of New Buildings 116 Use of Recycled Materials 4.3 Structural
More informationORDINANCE NO. 16- The City Council of the City of West Hollywood does hereby ordain as follows:
Page 1 ORDINANCE NO. 16- AN ORDINANCE OF THE CITY OF WEST HOLLYWOOD ESTABLISHING SEISMIC STRENGTHENING REQUIREMENTS FOR FOUR CATEGORIES OF EXISTING BUILDINGS IN THE CITY AND AMENDING THE WEST HOLLYWOOD
More informationPatio Cover Manufacturers and other Interested Parties
To: From: Patio Cover Manufacturers and other Interested Parties ICC-ES Date: February 6, 2009 Subject: Technical Review of Patio Cover Engineering Analysis in Accordance for Patio Covers (AC340) MEMO
More informationThe International Building Code (IBC ) is a model code that provides minimum requirements to safeguard the public health, safety and general welfare
AIA Austin is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this program will be reported to AIA/CES for AIA
More informationINSTRUCTORS GUIDE. FEMA P-593 CD, Seismic Rehabilitation Training for One- and Two-Family Wood-Frame Dwellings
INSTRUCTORS GUIDE FEMA P-593 CD, Seismic Rehabilitation Training for One- and Two-Family Wood-Frame Dwellings ****************************************************************************** This Instructors
More informationCHAPTER 6 BUILDING REGULATIONS ARTICLE I - BUILDING CODES
CHAPTER 6 BUILDING REGULATIONS ARTICLE I - BUILDING CODES 6-1-1 PURPOSE. The purpose of this Article is to provide for safety, health public welfare through structural strength and stability, means of
More informationSOUTHERN NEVADA AMENDMENTS TO THE 2009 INTERNATIONAL RESIDENTIAL CODE
SOUTHERN NEVADA AMENDMENTS TO THE 2009 INTERNATIONAL RESIDENTIAL CODE First Printing: December 17, 2010 Clark County Ronald L. Lynn 4701 W. Russell Road Las Vegas, Nevada 89118 (702) 455-3000 Inspections
More informationGene Stevens - J. R. Harris & Company 1
SEAC Existing Structures Committee Examining Issues of Existing Structures: IEBC I know what to do! Why do I need such a complex Code? Mostly, it is a simple question of - when is it necessary to structurally
More informationCITY OF CHEYENNE 2018 CODE ADOPTIONS
CITY OF CHEYENNE 2018 CODE ADOPTIONS Town Hall meeting 9-25-18 Public Safety Center 415 W. 18 th St Blas Hernandez CBO bhernandez@cheyennecity.org PH: 307-637-6276 Proposed changes are visible by visiting
More informationSEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON STRUCTURAL EVALUATION FOR PREPARED BY PCS STRUCTURAL SOLUTIONS
STRUCTURAL EVALUATION FOR SEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON PREPARED BY PCS STRUCTURAL SOLUTIONS NOVEMBER 1, 2017 17-733 TABLE OF CONTENTS Page I. PREFACE ii II. EXECUTIVE
More informationChapter 1: Application and Administration
Chapter 1: Application and Administration General Comments This chapter provides provisions regarding the purpose, scope, application, and administration of subsequent requirements of ICC 500. In addition
More informationFollowing are the NMHC/NAA Recommendations for the ICC Online Consensus Voting which opens on February 8 th, 2016:
Following are the NMHC/NAA Recommendations for the ICC Online Consensus Voting which opens on February 8 th, 2016: These recommendations are only for those issues that are of concern to the multifamily
More informationCHAPTER 34 EXISTING BUILDINGS
CHAPTER 34 EXISTING BUILDINGS SECTION 3401 GENERAL 3401.1 Scope. Provisions of this chapter shall govern the application of this code to existing buildings. Exception: Buildings and structures located
More information&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &
&01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.
More informationWhat is Conventional Construction?
What is Conventional Construction? Copyright This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission
More informationThe Council of the City of Palo Alto does ORDAIN as follows:
ORDINANCE NO. 4976 ORDINANCE OF THE COUNCIL OF THE CITY OF PALO ALTO REPEALING CHAPTER 16.04 OF THE PALO ALTO MUNICIPAL CODE AND AMENDING TITLE 16 TO ADOPT A NEW CHAPTER 16.04, CALIFORNIA BUILDING CODE,
More informationSummary of Key Changes
9 th Edition of the Massachusetts Building Code () Summary of Key Changes Below is a summary of key changes between the current 8 th and proposed 9 th editions. The 8 th edition used the 2009 model codes
More informationSection 1 Introduction
Section 1 Introduction Concern over the possibility of damaging earthquakes in the eastern United States developed through the 1970 s as a result of improved knowledge of both the history of eastern U.S.
More informationICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS
ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS ICC 500-2013 edition Public Comment Draft #2 The ICC Consensus Committee on Storm Shelters has held 1 public meetings to develop the
More informationTechnical Assignment #3 November 15, 2004 Lateral System Analysis and Confirmation Design
Executive Summary Technical Assignment #3 November 15, 2004 Lateral System Analysis and Confirmation Design The Food Science Building in State College, Pennsylvania is a four story above ground steel composite
More informationFEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION
INTRODUCTION Objective of provisions: The provisions of IEBC Appendix Chapter A3 are intended to reduce hazard of earthquake-induced damage (IEBC A301.1). These provisions are not intended to eliminate
More information0306 SEISMIC LOADS GENERAL
0306 SEISMIC LOADS 0306.1 GENERAL Every structure, and portion thereof, including nonstructural components such as architectural, mechanical, and electrical components, shall be designed and constructed
More information2007/2008 PROPOSED CHANGES TO THE INTERNATIONAL EXISTING BUILDING CODE EXISTING BUILDING CODE COMMITTEE
2007/2008 PROPOSED CHANGES TO THE INTERNATIONAL EXISTING BUILDING CODE EXISTING BUILDING CODE COMMITTEE Steven L. McDaniel, CPCA Chair Building Official City of Corning Corning, NY Jonathan C. Siu, SE
More informationDepartment of Public Safety and Corrections Uniform Construction Code Council. Uniform Construction Code (LAC 55:VI.301)
Department of Public Safety and Corrections Uniform Construction Code Council Uniform Construction Code (LAC 55:VI.301) In accordance with the provisions of R.S. 40:1730.26 and R.S. 40:1730.28, relative
More informationPRESCRIPTIVE COMPLIANCE METHOD
CHAPTER PRESCRIPTIVE COMPLIANCE METHOD 3 SECTION 301 GENERAL 301.2 Building materials. Building materials shall comply with the requirements of this section. 301.2.1 Existing materials. Materials already
More informationINTERNATIONAL EXISTING BUILDING CODE
INTERNATIONAL EXISTING BUILDING CODE EB14-06/07 202 Proposed Change as Submitted: Proponent: Maureen Traxler, City of Seattle, Washington, representing Washington Association of Building Officials Revise
More informationHAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS
Appendix A HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS PROJECT PERMIT APPLICANT PRIMARY RDP OF RECORD STRUCTURAL ENGINEER OF RECORD This Statement of Special Inspections is submitted as a condition
More informationQuestion 8 of 55. y 24' 45 kips. 30 kips. 39 kips. 15 kips x 14' 26 kips 14' 13 kips 14' 20' Practice Exam II 77
Question 8 of 55 A concrete moment frame building assigned to SDC = D is shown in the Figure. Equivalent lateral force analysis procedure is used to obtain the seismic lateral loads, E h, as shown. Assume
More information9/19/2018. Session: 2018 IEBC Essentials - History
9/19/2018 Session: 2018 IEBC Essentials - History 1 2018 IEBC Essentials Part 1 Based on the International Existing Building Code (IEBC ) Introductions Instructor Provided assistance to: New Jersey HUD
More informationA BILL FOR AN ORDINANCE
A BILL FOR AN ORDINANCE ORDINANCE NO: 23 SERIES OF 2013 INTRODUCED BY: COUNCILMEMBER ROEMER AN ORDINANCE REPEALING AND REENACTING ARTICLES 2 THROUGH 8 OF CHAPTER 18 OF THE GREENWOOD VILLAGE CODE TO ADOPT
More information2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E.
2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E. The 2015 Edition of Special Design Provisions for Wind
More informationTHE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:
ORDINANCE NO. An ordinance amending Divisions 93 and 95 of Article I of Chapter IX of the Los Angeles Municipal Code to establish mandatory standards for earthquake hazard reduction in existing wood-frame
More informationSEISMIC DESIGN GUIDELINES
INTRODUCTION The purpose of these Seismic Design Guidelines is to provide additional information and clarification to Civil or Structural engineers in order to comply with Ordinance No. 18-O- 2767 for
More informationTHE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:
ORDINANCE NO. An ordinance amending Divisions 93 and 95 of Article I of Chapter IX of the Los Angeles Municipal Code to establish mandatory standards for earthquake hazard reduction in existing wood-frame
More information2012 NC Energy Conservation Code (2012 NCECC) Commercial Building Compliance
2012 NC Energy Conservation Code (2012 NCECC) Commercial Building Compliance Billy Hinton, PE NC Department of Insurance Engineering Division Code Services Section Objectives Today we will address: 1.
More informationDRAFT ORDINANCE NO. RD:JAC:CER 9/1/2016
ORDINANCE NO. DRAFT AN ORDINANCE OF THE CITY OF SAN JOSE AMENDING VARIOUS SECTIONS OF TITLE 24 (TECHNICAL CODES) OF THE SAN JOSE MUNICIPAL CODE TO ADOPT THE 2016 CALIFORNIA BUILDING, RESIDENTIAL, PLUMBING,
More informationLEAD DESIGN PROFESSIONAL:
2009 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:
More information2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)
2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:
More informationCTC to BCAC IBC/ADA Coordination/ IEBC 3-2, 4-1 thru 4-8a, 7-1 thru 7-3, 8-1, 12-1, 14-1 and 15-1
CTC to BCAC IBC/ADA Coordination/ IEBC 3-2, 4-1 thru 4-8a, 7-1 thru 7-3, 8-1, 12-1, 14-1 and 15-1 2015 Group A Code Change Cycle Copyright 2014 International Code Council, Inc. IEBC 3-2 301.1 Proponent:
More information9th Edition Residential Volume with MA Amendments - Flood Standards Only DRAFT. 9th Edition Massachusetts Residential Code Requirements in Floodplains
9th Edition Massachusetts Residential Code Requirements in Floodplains This unofficial document was prepared to serve as a guide for using the flood standards in the Massachusetts Building Code 9th Edition
More information2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)
2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:
More informationAKF Group LLC. A. Vernon Woodworth FAIA
AKF Group LLC 780 CMR 9 th Edition: Major Changes AKF T A. Vernon Woodworth FAIA 3/14/17 Credit(s) earned on completion of this course will be reported to AIA CES for AIA members. Certificates of Completion
More informationTwo Stage Analysis Procedure: Wood on Podium Design
Two Stage Analysis Procedure: Wood on Podium Design Part 1: Flexible Upper Portion Jared Cope, S.E. Two Stage Analysis Procedure: Wood on Podium Design 1 Two Stage Analysis: ASCE 7-10 Chapter 12 12.2.3.2
More informationInternational Building Code 2009
Attachment B. Flood Provisions of the 2009 I-Codes International Building Code 2009 (prepared by FEMA, December 2008) Chapter 1 Administrative 101.2 Scope. The provisions of this code shall apply to the
More informationTable of Contents 2. Structural Systems.4 Foundations.4 Floor System...4 Columns..5 Lateral System...5
WISCONSIN PLACE RESIDENTIAL TECHNICAL ASSIGNMENT 1 OCTOBER 5, 2007 KURT KRASAVAGE THE PENNSYLVANIA STATE UNIVERSITY STRUCTURAL OPTION FACULTY ADVISOR: DR. ALI MEMARI Table of Contents Table of Contents
More informationNOTE: For construction other than new commercial or additions (renovations), only those areas below describing the scope of work will be applicable.
Applicant s Name: New Commercial - Commercial Additions Renovations Permit Plan Submittal Check List Applicant s Phone Number (s): Project Address: Project Type: _New Commercial or Commercial Addition
More informationInternational Building Code Chapter 16 Part 3 File Type
We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with international building
More informationINGHOUSE Page 1 of 48
INGHOUSE Page 1 of 48 Lars Jensen P.E., S.E. Web: www.inghouse.net EMAIL: jensen@inghouse.net INGHOUSE Page 2 of 48 OBJECTIVES: DESIGN OPTIONS; WHY ENGINEERED DESIGN DEVELOP AN UNDERSTANDING OF MAGNITUDE
More informationCHAPTER 6 INTERNATIONAL RESIDENTIAL CODE
CHAPTER 6 INTERNATIONAL RESIDENTIAL CODE Sec.3-6-1. Adoption of the International Residential Code. That certain documents three copies of which are on file in the office of the village clerk, being marked
More informationMinnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017
Minnesota Healthcare Engineers Association, Fall Conference Bob Dehler, P.E. Engineering Program Manager September 14, 2017 Categories of Rehabilitation Work in Healthcare Facilities Bob Dehler, P.E. robert.dehler@state.mn.us
More informationReroofing Requirements for Commercial Buildings in the 2015 International Energy Conservation Code
Reroofing Requirements for Commercial Buildings in the 2015 International Energy Conservation Code NEBOEA 2015 Michael Fischer, Kellen Company The Polyisocyanurate Insulation Manufacturers Association
More information90% Design Submittal Structural Calculations Parking Garage CDRL
NORTH METRO RAIL LINE PROJECT Thornton Crossroads at 104 th Avenue Station 90% Design Submittal Structural Calculations Parking Garage CDRL 03-037.11.06 June 2, 2017 Prepared by: Regional Rail Partners
More informationTable 1. Detailed Comparison of Structural Provisions of 2000 IBC to 1997 NEHRP (continued)
1997 NEHRP 2000 IBC Section Provision Section Provision Comments 1 GENERAL PROVISIONS 1.1 PURPOSE No corresponding provision The lack of a purpose statement does not make IBC 1.2 SCOPE AND APPLICATION
More informationNorth Shore at Canton Baltimore, MD Beau Menard Technical Report 1
North Shore at Canton Baltimore, MD Beau Menard Technical Report 1 Structural Schneider 10/05/05 Structural Concepts Executive Summary North Shore at Canton is a 4 story town home and parking garage structure
More informationRESPONSIBILITIES IN THE DESIGN PROCESS INVOLVING METAL PLATE CONNECTED WOOD TRUSSES
CHAPTER 2 RESPONSIBILITIES IN THE DESIGN PROCESS INVOLVING METAL PLATE CONNECTED WOOD TRUSSES 2.1 PURPOSE The purpose of this chapter is as follows: 2.1.1 To define and draw attention to the typical duties
More information