Installation instructions

Size: px
Start display at page:

Download "Installation instructions"

Transcription

1 Installation instructions Holetherm Double-walled flue gas discharge system (DW) 2016

2 All information in this release is subject to misprints. No liability is accepted for the consequences of misprints. Holetherm reserves the right to change information, including the text of this disclaimer, at any time, without notice in this regard. This disclaimer is governed by Dutch Law.

3 Index 1 General Introduction 4 2 Quality standards Declaration of Performance Certification Characteristics channel load and resistances 4 3 Instructions Laws and regulations Application Characteristics of the material 6 4 Fire safety and channel installation Fire safety Channel installation Penetrations and casing Outlet 8 5 Dilution factor Calculation A detailed example 9 6 Assembly System construction Bending From double-walled (DW) to single-walled (SW) Roof installation Channel maintenance 11

4 1 General 1.1 Introduction These installation, assembly and maintenance instructions were published to ensure the safety of the product, in a construction environment. They have been drawn up according to the current state of science and technology and serve only as a general guideline. This guideline may be amended regularly based on new insights and regulatory requirements. The current version can be viewed on These instructions have been drawn up with the utmost care. The installer remains responsible for the correct installation of our materials, based on his or her skills. Holetherm shall never accept liability for possible damages resulting from plainly following these instructions in practice. If you have any doubts about the implementation and application, contact one of our experts first. 2 Quality standards 2.1 Declaration of Performance From 1 July 2013, manufacturers, importers and distributors of construction products must provide a Declaration of Performance (DoP) for products to which a harmonised European standard applies. Holetherm DW has classified the DoP statement for its products, per product group. The appropriate DoP number is listed on the product labels and delivery documents. 2.2 Certification The Holetherm DW flue system conveying flue gas, is produced in the Netherlands. The production is certified and monitored by KIWA, under the requirements set in Construction products directive 89/106/EEC. The EC Declaration of Conformity, stating that the product, Holetherm DW, meets the CE requirements, as set out in the European Standard DIN EN :2009 for system 2+. This statement has been tested and issued by Kiwa Cermet Italia S.p.A, under certificate registration number 0476-CPR-6883 Rev.01 dated Contract No. C9820. Figure Characteristics channel load and resistances Kanaalsysteem (Channel system) Holetherm DWT6OQ-N1-D-V2-L50040/050-G75 Load and resistance with a total of seven metres of channel sections. 4

5 Heat resistance Heat resistance with a diameter of ø80 to ø250 mm = 0.42 m² K/W and from ø251 to ø450 mm = 0.46 m² K/W. Fire safety Chimney fireproof: Yes. Bending load Non vertical installation: maximum distance between 2 supports is 1.5 metres at 45. Wind load Maximum detached height 1.5 metres from the last support. Flow resistance Length=1.0; elbow 15 =0.3; elbow ; T-piece ; T-piece 90 =1.2. Freeze/thaw resistant: yes. Legend T6OQ-N1-D-V2-L50040/050-G75 T-600 temperature level N1 pressure level of 40 Pa vacuum D condensation resistance, (W=wet D=dry) V2 corrosion resistance determined by material type L5004O/50 material specifications , (0.4 mm or 0.5 mm thick) G chimney fireproof, (G=yes O=no) 75 minimum distance in mm, to combustible materials (TAKE NOTE with diameters of DW300 and larger, 1.5 x this distance applies = 113 mm) 3 Instructions 3.1 Laws and regulations The Holetherm flue system conveying flue gas must be installed according to the applicable laws and regulations, and meet the current construction regulations. The installation of the Holetherm DW flue system conveying flue gas must meet the fire safety provisions set out in NEN Application The Holetherm DW is suitable for standardised liquid and gaseous fuels with a maximum flue gas temperature of 600 C. The flue gas outlet is called a pressurised system, this means that the pressure in the channel, under normal operating conditions, is lower than the air pressure of the environment. 5

6 3.3 Characteristics of the material Holetherm DW Stainless Steel flue gas canal: Outer wall: (304) Inner wall: (316L) Holetherm DW (Figure 1 and 2) is a comprehensive concept and connectable to Holetherm EW. The product is not interchangeable with or connectable to products from other manufacturers. If you make changes and/or adjustments to the Holetherm DW concept, this may adversely affect the proper functioning thereof. Any guarantee and liability expires when such adjustments are made. For an overview of the components, refer to the product catalogue on our website Figure 2 4 Fire safety and channel installation 4.1 Fire safety According to the building regulations, a chimney must be encased inside buildings and ducts, in a wall or floor and in places where the fire resistance of the structure is adversely affected. Holetherm is a channel that may not be installed independently. This means that, if physical contact with the channel is possible in areas where the source of heat is not located, the channel sections need to be encased. In situations where the floors are not fire resistant, the covering may only be closed off with a fire separation plate at the bottom. In case of flammable material, the casing between floors in the floor passages must run through and remain open. This will prevent heat accumulation from occurring inside the casing. Applicable standards can be found in the Building regulations, and the provision for fire safety can be found in NEN6062. Holetherm DW has been tested by TNO according to NEN6062, TNO report 94-CVB-R048.6 The NEN6068 standards define the resistance against fire penetration and transfer between spaces mutually. Depending on the situation on site, this may vary between 30 or 60 minutes. Finally, NEN-EN is of great importance. According to this standard, the Holetherm CC is approved for T450 flue gas temperature. Before an installation can be fitted, the conduit route should be inspected in the intended route. The conduit route must meet the regulations set out in the Building Regulations. The application of the flue gas outlet in existing partitions and casings, should also meet the fire safety requirements in NEN Channel installation The flue gas outlet must be built from the connection to the combustion unit to the outlet on the roof. The channel must be installed as vertically as possible. Holetherm DW channels or channel sections may only be installed to the combustion unit, not in a horizontal position. The maximum angle for an elbow in the vertical channel is

7 4.3 Penetrations and casing Ensure that the passage openings in a non-combustible (stone-like) floor remain free for at least 2 mm around the installed Holetherm DW channel. With a combustible floor, the opening around should be at least 75 mm. Always finish such openings with fire-resistant material. The fire-resistant materials should always be applied in accordance with the instructions of the manufacturer and the Building Regulations. The opening in a flammable roof and/or roof board must be the same size as the outer diameter of the casing to be installed. The sleeve must go through the roof boarding and connect to the roof finish. Always finish the surrounding combustible materials around the channel off as described above. For the Holetherm DW with an internal diameter of 300 mm or more, you should keep a distance of at least 113 mm from combustible materials. One again, finish off all combustible materials with fire-resistant materials. All materials on the inside of the casing should always be made of non-combustible materials. The material thickness of the casing must be at least 12 mm, e.g. Promatect fire-resistant construction sheeting. Never use a fire separation plate within a casing, this separation allows for an accumulation of heat by blocking the air flow within the casing. Sleeving bracket Sleeving bracket Non-combustible insulation material Opening between channel and floor Stone-like floor Combustible floor Figure 3 Depending on RGA diameter Depending on RGA diameter 7

8 4.4 Outlet The location of the outlet of the flue channel must be chosen with care, the best position is the ridge of the roof, or as close as possible to this area. With a roof slope of less than 23, the outlet should be 0.5 meter above the roof. For roofs with a slope greater than 23, the following formula applies H (α 23)a H = height of the outlet A = Roof slope in degrees a = The horizontal distance from the ridge to the centre line of the outlet 5 Dilution factor 5.1 Calculation The dilution factor is a measure of the quality of the supplied air. The dilution factor is calculated from the distance between the outlet of a ventilation or flue gas outlet, and the inlet of the ventilation supply provisions. The following requirements apply to the dilution factor: Table 1 Dilution factors with various types of outlets. Type of outlet Dilution factor Ventilation air outlet 0.01 Flue gas fuelled unit 0.01 Flue gas unit for other fuels A dilution factor of 0.01, for example, means that no more than 0.1% contaminated indoor air or smoke ends up in the fresh air. To calculate the dilution factor, the following information has to be available: The required air volume flow qv for the outlet of the indoor air or the load B for the outlet of smoke from a combustion unit. The shortest distance L between the outlet of the ventilation/flue gas outlet and the inlet opening(s) for ventilation air. The mutual difference in height Δh of the outlet and the supply opening. The placements, corresponding to the situations 1 through 17 according to table 4 from NEN The following formulas can be applied: 8

9 5.2 A detailed example Step 1 This involves a supply and outlet provision for ventilation. The required air volume flow rate qv for the outlet of the indoor air is 42 l/s. Step 2 The shortest distance L between the ventilation outlet and supply system is 1 m horizontal to the roof edge. Step 3 The difference in height Δh = 0.5 m between the ventilation supply system and the roof edge. Step 4 This concerns situation 1, outlet in the roof surface and supply through the wall. (refer to the following diagram) 1 m 0,5 m Drain 42l/s Supply Residence Dilution factor Fig. 1 Cross-Section of a residence to calculate the dilution factor If we fill in the date, this results in a dilution factor of This meets the requirement of Take note! The calculation method for the dilution factor is not intended to counteract odour pollution, but only to prevent situations that may be harmful for the health. There are no public requirements for the distance between a ventilation air supply and a sewer vent. Additional requirements with respect to the dilution are contained in the method in NEN 3215/NTR

10 6 Assembly 6.1 System construction Build the system from the combustion unit. The various sections are inserted into each other as a socket connection. Slide the channel with the plug connection in the socket, from the section beneath it. This is necessary because the Holetherm DW is an inward draining system. A reverse installation could potentially lead to leakage problems, possibly resulting in penetrating rainwater or condensation forming within the channel. Therefore, during installation, take note of the arrow printed on every section; this indicates the direction to the gas flue outlet. Figure 4 Use a connecting piece for connection to a stove or fireplace. If your stove or fireplace has a rear connection, two elbows of 45 must be installed immediately after the connection piece, to prevent horizontal channel sections. In order to support your Holetherm DW, it is important that you insert a seat structure in the vertical channel immediately after the horizontal cross-over (Figure 4). Elbows should be mounted stress free, and a new seat structure should be installed after every seven metres of channel length. 6.2 Bending If an elbow is required in the route, only one bend is allowed. The maximum bending into the flue gas outlet may not exceed 2 metres. If you pass through a wall opening in stone-like material, you should consider a 20 mm distance around the channel on the back of your stove or fireplace. Never fix the channel in concrete or cement, since there will be no relief for the thermal effect. Secure the first vertical channel section after the connecting piece, with a wall bracket. After this a wall bracket must be applied after every 1.5 metres. To apply a casing, use the Holetherm sleeving bracket rather than a wall bracket (Figure 5). 6.3 From double-walled (DW) to single-walled (SW) If you switch from a Holetherm DW channel to a SW channel, use the contra connection piece DW. This connection piece was designed to create a reliable connection between the two channels and seals the insulation material from moisture and dirt, in a correct manner. Use the Holetherm connection piece when switching from SW to DW. Figure 5 10

11 If your flue gas outlet from the living room starts off as SW and you want to switch to a DW Holetherm channel beneath the ceiling, ensure that, with a non-combustible floor, the connection is at least 50 mm beneath the ceiling. In case of a combustible floor, this connection should at least be 200 mm. Install a fire separation plate around this floor conduit and finish the conduit in the ceiling as described in the conduit and encasing 4.5. Figure 6 Fix the various channel components with the accompanying Stainless Steel clamping strip. These clamping strips are used to make a tensely strong connection between the components of the system (Figure 6). 6.4 Roof installation A fire separation plate is also used with an installation on the roof, in the event of a sloping roof this fire separation plate will have to be used in the sloping position. A roof bracket is used at the roof outlet (Figure 7). Depending on the roof finish, a roof plate or counter flashing is used. At the end of the conical cone of this roof plate or counter flashing, install a storm collar. This can be sealed with a heat resistant silicone sealant. Finally, you install the end cap. If the outlet is at risk of over pressure as a result of downward wind caused by the surrounding buildings, you should install an extraction cap. Figure Channel maintenance More information can be found on our website ( Depending on the use, ensure that your chimney is cleaned 1 to 4 times a year by an accredited chimney sweeper. If you experienced a chimney fire, your channel should always be assessed on reusability of the channel components, by a competent authority. 11

12

Installation instructions

Installation instructions Installation instructions Holetherm Single-walled flue gas discharge system (EW) 2016 All information in this release is subject to misprints. No liability is accepted for the consequences of misprints.

More information

Declaration of Performance (DOP)

Declaration of Performance (DOP) Declaration of (DOP) No. 9174 073 DOP 2015-07-27 1. Unique identification code of the product-type: Multi-wall chimney system type FURADO-F according to 2. Type, batch or serial number or any other element

More information

InoxSabiana 25 Flues. Stainless Steel Double Wall

InoxSabiana 25 Flues. Stainless Steel Double Wall Cert. n 0545/5 Flues Stainless Steel Double Wall Introduction and main constructional characteristics Double Wall, Stainless Steel Flues The is the result of innovative development based on over 0 years

More information

Declaration of Performance (DOP)

Declaration of Performance (DOP) Declaration of Performance (DOP) No. 9174 009 DOP 2014-01-27 1. Unique identification code of the product-type: Multi-wall chimney system type DW-VISION according to 2. Type, batch or serial number or

More information

Product catalogue. Socket cast iron pipe system

Product catalogue. Socket cast iron pipe system Product catalogue Socket cast iron pipe system GALLERY ADVANTAGES OF SOCKET PIPE SYSTEM Classic form: Fits well the architecture of renovated buildings. Wide range of products: Pipes, siphons, stormwater

More information

Air flue duct for use with ecotec boilers

Air flue duct for use with ecotec boilers For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation

More information

Issued in accordance with the Construction Products Directive 89/106/EEC. Oude Veerseweg 23 Middelburg - The Netherlands

Issued in accordance with the Construction Products Directive 89/106/EEC. Oude Veerseweg 23 Middelburg - The Netherlands EC-DECLARATION OF CONFORMITY Page 1 / 6 0432 Issued in accordance with the Construction Products Directive 89/106/EEC Product: Twin walled stainless steel system chimney products with insulation System

More information

Installation instruction

Installation instruction Installation instruction Ci51 www.contura.eu 114 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci51-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing

More information

EEC-DECLARATION OF CONFORMITY

EEC-DECLARATION OF CONFORMITY 0432 EEC-DECLARATION OF CONFORMITY Herewith, the : interactive B.V. Lichtenhorststraat 2 Postbus 200 6940 HA Didam (NL) declares that, in accordance with EEC-Construction Products Directive 89/106/EEC,

More information

female pipe. A Wall Support must be installed just above the tee and at least every 8 feet thereafter. If the pipe is to be run through a roof overhang then a Flashing, Storm Collar and Vertical Rain Cap

More information

Technical and Dimensional Data. Saf-T Vent SC

Technical and Dimensional Data. Saf-T Vent SC Technical and Dimensional Data Saf-T Vent SC 3"/5" & 4"/7" Concentric Reduced Clearance Double Wall for Special Gas Vent and/or Sealed Combustion Systems Copyright 2003 Saf-T Vent is a registered trademark

More information

Product catalogue. Socket cast iron pipe system

Product catalogue. Socket cast iron pipe system Product catalogue Socket cast iron pipe system KZO S.A. Dear Customers, For decades, KZO S.A. has been the leading manufacturer of socket cast iron pipes and fittings. Long tradition and experience allowed

More information

Installation Instructions

Installation Instructions Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury,

More information

Product catalogue. Socket cast iron pipe system

Product catalogue. Socket cast iron pipe system Product catalogue Socket cast iron pipe system ADVANTAGES OF SOCKET PIPE SYSTEM Classic form: Fits well the architecture of renovated buildings. Wide range of products: Pipes, siphons, stormwater dampers,

More information

40CDi conventional. RD 537i. Installation Instructions for Flue Duct Kit AZB 873/1 Vertical Flue Terminal Assembly Ø 60/100 mm Ø135

40CDi conventional. RD 537i. Installation Instructions for Flue Duct Kit AZB 873/1 Vertical Flue Terminal Assembly Ø 60/100 mm Ø135 Installation Instructions for Flue Duct Kit AZB 873/1 Vertical Flue Terminal Assembly Ø 60/100 mm 7 719 002 430 Ø100 Ø62 1140 116 3x Ø135 2x Ø100 4x 6 720 611 739-00.1O for Gas Condensing Boilers: R 29

More information

DINAK Camiño do Laranxo, , VIGO (SPAIN) DIFLUX POLYPOPRYLENE. TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD

DINAK Camiño do Laranxo, , VIGO (SPAIN) DIFLUX POLYPOPRYLENE. TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD Rev.2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 14471 Chimneys - System chimneys with plastic flue liners - Requirements and test methods Manufacturer: Product commercial name: Product description:

More information

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314 CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey

More information

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314 CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey

More information

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual Please see IB series product installation guide for details of installing the gas fire into this preformed metal cavity. Important: The appliance

More information

These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues

These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues ADDRESS Jetmaster Fires Ltd Unit 2, Peacock Trading Estate Goodwood Road Eastleigh Hampshire`

More information

INSTRUCTION MANUAL OF INSTALLATION, SELECTION AND OpERATION OF METAL CHIMNEYS AND THEIR SYSTEM ELEMENTS

INSTRUCTION MANUAL OF INSTALLATION, SELECTION AND OpERATION OF METAL CHIMNEYS AND THEIR SYSTEM ELEMENTS INSTRUCTION MANUAL OF INSTALLATION, SELECTION AND OpERATION OF METAL CHIMNEYS AND THEIR SYSTEM ELEMENTS Edition No. 6 Approved: 2017-02-05 2017 Manufacturer: SAURESTA UAB Rasų street 39, LT-11351 Vilnius,

More information

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems) C US INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems) A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN

More information

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations... These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) CFDM. It is valid for production, designing, ordering, delivery, assembly and operation.

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS ULEB 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

Rediflow Concrete Gas Flue System

Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3 and 4. R1001.2 Footings and foundations.

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3

More information

Tested to BS EN and BS EN 1443

Tested to BS EN and BS EN 1443 Tested to BS EN 1856-2 and BS EN 1443 Introduction Page 2 Midtherm Flue Systems Limited is an independent British manufacturing company producing a wide range of flue and chimney products, along with associated

More information

Installation GUIde Please read these instructions before proceeding

Installation GUIde Please read these instructions before proceeding Installation GUIde Please read these instructions before proceeding Installing your Earthfire is a relatively straight forward job, but there are several key aspects that may seem arbitrary to the general

More information

SI T T FSS/FSTT Open Fire

SI T T FSS/FSTT Open Fire SI 440-600-700-700T-780-780T-900-1100 FSS/FSTT Open Fire Freestanding Solid Fuel Burner - Indoor Open Wood Fire Available in Square Top or Taper Top Options Installation Instructions Note: Flue System

More information

Installation Instructions. PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Flex

Installation Instructions. PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Flex Installation Instructions PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro Flex A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner

METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner Models CBI Cat. I: Part 1 CBH Cat I, II, III, IV: Part 2 3STS This symbol shows that venting systems Models CBI and CBH are Listed

More information

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8. Model P36-NG10 P36-LP10 P36E-NG10 P36E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Gas Fireplaces P36-10 / P36E-10 Gas Fireplace Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa)

More information

SECTION FIRESTOPPING

SECTION FIRESTOPPING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 84 00 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE Model P33-NG10 P33-LP10 P33E-NG10 P33E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) Manifold

More information

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit)

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit) Flue gas kit DN60 rigid in the duct 100193 Flue gas kit No Outlet set plastic 1 x Set 100193 39.10 (Quantities in the image differ from the set) 1003253 1001938 Spacer set * ( pieces) Top inspection opening

More information

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE Blast Resistant Enhanced Curtain Wall Blast Resistant Enhanced Curtain Wall Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

2. Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4):

2. Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4): 1. Unique identification code of the product-type: Rigid and flexible flue liner type TEC-FLEX 2. Type, batch or serial number or any other element allowing identification of the construction product as

More information

FLUE KIT INSTALLATION MANUAL

FLUE KIT INSTALLATION MANUAL FLUE KIT INSTALLATION MANUAL 7 76 9 55 ROOM SEALED TELESCOPIC FLUE 7 76 9 086 PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR USE WITH WORCESTER GREENSTAR GAS-FIRED APPLIANCES: Greenstar FS

More information

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers. SECTION 230529 - HANGERS AND SUPPORTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Sleeves. 6. Mechanical sleeve seals. 7. Firestopping

More information

Installation instructions

Installation instructions Installation instructions for contractors Flue gas system for Vitocrossal (type CU3), Vitodens and Vitoladens Safety instructions Please follow these safety instructions closely to prevent accidents and

More information

Midtherm Vitrelux flue pipe is available from stock, in the following standard colours and diameters, unless otherwise stated:

Midtherm Vitrelux flue pipe is available from stock, in the following standard colours and diameters, unless otherwise stated: Introduction Midtherm Flue Systems Limited is an independent ritish manufacturing company producing a wide range of flue and chimney products, along with associated components and services. Established

More information

Curtain Wall Stick System (Capped)

Curtain Wall Stick System (Capped) Curtain Wall Stick System (Capped) Stick Construction Capped Curtain Wall Reference Brand: Sapa Building System Elegance 52 ST GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES Prepared By Office of State Fire Marshal Maine Office of Energy Resources 52 State House Station 55 Capital Street Augusta, ME 04333 Augusta,

More information

SRP-AirOutshield UV Issued:

SRP-AirOutshield UV Issued: SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing

More information

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES 04 05 PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Over floor trunking 0 300 9 0 300 93 0 38 00 Conform to standard EN 50085-- For creating a link between trunking, column,

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit HT-K - Horizontal Flue Gas System For GB125 Oil Condensing Boiler For trained and certified Installers Please read carefully prior to installation. 6

More information

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. DuraFlex Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. Specifications DuraFlex SW Applications DuraFlex SW smooth wall flexible relining for masonry chimney. Use with gas,

More information

SPECIFICATION OPTICAL TERMINATION PANEL

SPECIFICATION OPTICAL TERMINATION PANEL SPECIFICATION OPTICAL TERMINATION PANEL Model Spec. No. VSOF-OTP-H VSS-0809-OTP-H-01A/SD Quality Assurance Team Distribution Depts. Manufacturing Division Sales Division Management Division Revision 09.

More information

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. DuraFlex Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. Specifications DuraFlex Pro Applications DuraFlex Pro ultra flexible relining for masonry chimney. Use with gas, wood

More information

Regency Horizon HZ30E Gas Fireplace

Regency Horizon HZ30E Gas Fireplace Specifications: Framing Dimensions: Model HZ3E-NG HZ3E-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent

More information

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720

More information

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth 28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1

More information

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as

More information

Dur aflex stainless steel

Dur aflex stainless steel Dur aflex stainless steel Simpson Dura-Vent Engineered Excellence DuraFlex SW DuraFlex SW is a smooth inner-wall, flexible stainless steel chimney liner. The smooth inner wall provides for no output reduction

More information

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014 Instructions for installation, operation and maintenance 0/204 General The rectangular smoke control damper ESAM is specially designed for use in multi fire-compartment applications as a closing or opening

More information

SI T T FST

SI T T FST SI 440-600-700-700T-780-780T-900-1100 Freestanding TAPER TOP Open Fire - Wood Burner Installation Instructions Note: FLUE SYSTEMS Casing. Flue System may require to be Doubled Lined to Comply. Ref ASNZS:2918:2001

More information

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

EPV Pellet Vent Pellet Stove Venting System Installation Instructions EPV Pellet Vent Pellet Stove Venting System Installation Instructions A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

ICC - Model VIP+ Positive Pressure Chimney System and Grease Duct

ICC - Model VIP+ Positive Pressure Chimney System and Grease Duct Scope and Recommendations ICC - Model VIP+ Positive Pressure Chimney System and Grease Duct INSTALLATION AND MAINTENANCE INSTRUCTIONS The ICC Model VIP+ is a double wall construction listed venting system

More information

INSTRUCTION MANUAL OF INSTALLATION, SELECTION AND OPERATION OF METAL CHIMNEYS AND THEIR SYSTEM ELEMENTS

INSTRUCTION MANUAL OF INSTALLATION, SELECTION AND OPERATION OF METAL CHIMNEYS AND THEIR SYSTEM ELEMENTS INSTRUCTION MANUAL OF INSTALLATION, SELECTION AND OPERATION OF METAL CHIMNEYS AND THEIR SYSTEM ELEMENTS Edition No. 4 Approved: 03 07 2016 2016 Manufacturer: SAURESTA UAB Rasų street 39, LT-11351 Vilnius,

More information

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations... These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) CFDM. It is valid for production, designing, ordering, delivery, assembly and operation.

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of

More information

APPLICATION AND LISTING

APPLICATION AND LISTING DURALINER (SDL) 6"-8" DIAMETER (ROUND & OVAL) INSTALLATION INSTRUCTIONS MH14420 CMH1329 THESE INSTALLATION AND OPERATION INSTRUCTIONS COVER DURALINER MASONRY RELINING SYSTEM A MAJOR CAUSE OF CHIMNEY RELATED

More information

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as

More information

HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction

HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction Models HEP HEPL HEPL2 28 KJ This symbol shows that CHEMINÉE LINING.E

More information

Technische Grundlagen

Technische Grundlagen Technische Grundlagen 47 Technical bases Technical bases for point drainage ACO bath drains are used in areas where there is a demand for functional long-life solutions with high flow volumes combined

More information

Concept XPS standard shower tray

Concept XPS standard shower tray Technical Sheet Concept XPS standard shower tray Comprehensive waterproofing system for built-in showers. The Concept XPS shower tray is a prefabricated system for built-in shower trays. They include the

More information

Leaving Certificate Revision Notes. Airtightness. Potential air leakage paths (the numbered points in section 2.1 give a description for

Leaving Certificate Revision Notes. Airtightness. Potential air leakage paths (the numbered points in section 2.1 give a description for Leaving Certificate Revision Notes Airtightness 6 7 8 8 9 10 5 11 5 12 4 3 1 2 13 12 14 Potential air leakage paths (the numbered points in section 2.1 give a description for Airtightness Introduction

More information

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work

More information

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations...

1. Description Damper Design Dimensions, weights Placement and Assembly Statement of installations... These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) CFDM. It is valid for production, designing, ordering, delivery, assembly and operation.

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

Dunbrik A1 Concrete Flue Liners

Dunbrik A1 Concrete Flue Liners Dunbrik A1 Concrete Flue Liners System Guide Firebelly stove FB2 woodburner in pewter domestic flue & chimney systems Certificate No.FM24104 Benefits of a Chimney A chimney adds appeal to a house A real

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

SECTION WELDED STEEL WATER STORAGE TANKS

SECTION WELDED STEEL WATER STORAGE TANKS SECTION 33 16 20 WELDED STEEL WATER STORAGE TANKS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Elevated tanks. 2. Appurtenances and accessories. B. Related Sections: 1. Section 03 31 20 - Concrete

More information

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev MANUAL METAL ROOF MOUNTING SYSTEM EN landscape orientation portrait orientation metal roof mounting system for solar panels ESDEC BV 2018 CONTENTS 1. Introduction 1 2. General installation conditions 1

More information

SRP-AirOutshield ROOF Issued:

SRP-AirOutshield ROOF Issued: SECTION 07276: Breathable Underlayment Guide Specification This specification is a guide only and may need editing for the specific intended application. It is the responsibility of the design professional

More information

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+ NEW Not just a vapour control layer, it also acts as supplementary insulation! VAPOUR CONTROL LAYER WITH BUILT-IN THERMAL PERFORMANCE C-6044-10 hcontrol reflex+ Air leakage in buildings can lead to a significant

More information

Supplementary Standard SB-12. Energy Efficiency For Housing

Supplementary Standard SB-12. Energy Efficiency For Housing OBC Excerpt: SB 12 Ministry of Municipal Affairs and Housing Building and Development Branch 2006 Building Code - Supplementary Standards Supplementary Standard SB-12 Energy Efficiency For Housing November

More information

EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS

More information

Skoberne Flue systems

Skoberne Flue systems Skoberne Flue systems Product Catalogue 2018 2 The Skoberne flue system The components of the Skoberne flue system are made of high quality, flame-retardant polypropylene. They are characterised by their

More information

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section ) 8-1200. International Residential Code. ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section 6-9-40) NOTE-This article

More information

Building Permit Application

Building Permit Application Building Permit Application Administrative Use Only PARENT PERMIT NUMBER (Required if part of another project) PERMITTEE: PERMITTEE ADDRESS: E-MAIL ADDRESS: ARCHITECT/ENGINEER: ARCHITECT/ENGINEER ADDRESS:

More information

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD. Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD. Included are selected sections of codes taken directly from: 1997 Uniform

More information

The most versatile "BIG SCREEN" high efficiency fireplace!

The most versatile BIG SCREEN high efficiency fireplace! ZERO CLEARANCE (ZC) The most versatile "BIG SCREEN" high efficiency fireplace! Endless opportunities True polyvalence Enjoy high efficiency fires or the cozy ambiance of open fires. BBQ cooking. Water

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Daytona Beach Pier Building Renovation Jun 2010

Daytona Beach Pier Building Renovation Jun 2010 SECTION 15150 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Fire Protection Valves

Fire Protection Valves 4/4/EN/6 Fire Protection Valves Type FV-K90 FVZ-K30 with German Test Certificate (General Building Approval) Z-41.3-317 Z-41.3-319 TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/202-265 Heinrich-Trox-Platz

More information

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS KEMDRAIN TM STAINLESS INDUSTRIAL FLOOR DRAINS AND LINEAR CHANNELS, OFFERING ALL THE BENEFITS OF 316L

More information

geba fire damper WFK according to EN 15650

geba fire damper WFK according to EN 15650 Installation- and operation instruction geba fire damper WFK according to EN 15650 with a free cross-section for the usage in ventilation systems in buildings Abbildung 1 DN 250 Tested according to EN

More information

New Home Warranty Handbook

New Home Warranty Handbook New Home Warranty Handbook Cabinets CB 1 Warping of doors and drawer faces should not exceed ¼ inch. Warping is measured from the face of the frame to the point of maximum warpage, with the door or drawer

More information

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction Pipeline Accessories PSI Wall Sleeves General Information Selection Guide Technical Data Installation Instruction 1 PSI Wall Sleeves made of steel General Information An economic method to seal hydrostatically

More information

Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS

Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS GENERAL INSTALLATION INSTRUCTIONS 1 Ensure that the trench where the channels are going to be installed has enough room for the appropriate

More information

Rainscreen Ventilated Fire Barrier

Rainscreen Ventilated Fire Barrier An intumescent FR barrier for slab edge, curtain wall and façade applications Technical Data Sheet KEY BENEFITS - Allows air movement in building design whilst providing superior fire rating - Fire Resistance

More information

Installation & User Manual

Installation & User Manual Desktop UHF Radio Paging System Installation & User Manual Scope Communications UK Ltd, Quantum House, Steamer Quay, Totnes, Devon TQ9 5AL Tel: +44 1803 860700 Fax: +44 1803 863716 Email: sales@scope-uk.com

More information

Clearly Solar. Installation Instructions. Solar Thermal Flat Plate Collector. Vertical On-roof mounting SHV

Clearly Solar. Installation Instructions. Solar Thermal Flat Plate Collector. Vertical On-roof mounting SHV Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Vertical On-roof mounting 15-75 SHV 2.3 www.glow-worm.co.uk 1 Guarantee Registration These Clearly Solar Flat Plate collectors

More information