PBR & PBU Panels. Technical/Installation Information

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "PBR & PBU Panels. Technical/Installation Information"

Transcription

1 PBR & PBU Panels Technical/Installation Information

2

3 TABLE OF CONTENTS A. PBR Panel 1. General Description Architect/Engineer Information Product Selection Chart Factory Mutual Approvals PBR Panel Section Properties PBR Panel Fastener Locations PBR Panel Allowable Uniform Loads PBR Panel UL 90 Requirements PBR Panel Product Checklist PBR Panel Attachment PBR Panel UL 90 Light Transmitting Panel Installation B. PBU Panel 1. General Description Architect/Engineer Information Product Selection Chart PBU Panel Section Properties PBU Panel Fastener Locations PBU Panel Allowable Uniform Loads PBU Panel UL 90 Requirements PBU Panel Product Checklist PBU Panel Attachment PBU Panel Light Transmitting Panel Installation C. Typical Details 1. Ridge High Side Eave Hip Valley Gutter Eave Trim Rake Parapet High Side Eave Parapet Rake Corner Corner Box Base Head Jamb D. Installation Guidelines Copyright Metal Building Components, L.P All Rights Reserved For the most current information on our products and erection procedures, please check the MBCI web site at Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To insure you have the latest information available, please inquire or visit our Web Site at Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs, or panel profiles. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices. Insulation is not shown in these details for clarity. If there is a conflict between this manual and the erection drawings, the erection drawings will take precedence. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

4 GENERAL DESCRIPTION PBR PANEL 12" 36" 1¹ ₄" PBR PANEL Coverage Width - 36" Minimum Slope - ¹ ₂:12 Panel Attachment - See page 8 Panel Substrate - Galvalume Gauge - 26 standard - 29, 24 and 22 also available Coatings- Galvalume Plus, Signature 200* and Signature 300* ARCHITECT/ENGINEER INFORMATION 1. PBR panel is a structural roof and wall panel. This panel can be installed directly over purlins or joists. Several different UL 90 construction numbers are available for this panel. 2. PBR panel is recommended for ¹ ₂:12 or greater roof slopes. 3. Field applied tape sealant is required at panel sidelaps and endlaps. 4. PBR panel is a through-fastened panel. For proper fastener application, see page 3 and page The information in this manual is believed to be correct and accurate. It should not be used for any specific application without being reviewed by a registered professional engineer. 6. Galvalume material must not come in contact with concrete or pressure treated lumber. PRODUCT SELECTION CHART GAUGE GALVALUME PLUS SIGNATURE 200* SIGNATURE 300* 22 gauge 24 gauge 26 gauge 29 gauge - Available in any quantity. - Minimum quantity may be required. *See Commercial/Industrial color chart for available colors. RATING PROFILE WIDTH GAUGE PURLIN PURLIN FASTENER NUMBER OF STITCH STITCH FASTENER (IN) SPACING GA. TYPE FASTENERS FASTENER SPACING PBR '-3 1 / 4 " 16 1 / 4-14 X 1 1 / 4 ZAC / 4-14 X 7 / 8 ZAC 11 20" o.c PBR '-3 1 / 4 " 16 Notes: 1 All roofs are Class Fastener #1E. 11 Fastener #4. FACTORY MUTUAL APPROVALS 1 / 4-14 X 1 1 / 4 ZAC / 4-14 X 7 / 8 ZAC 11 20" o.c. State of Florida Approval Numbers: FL (roof), FL (wall), FL5222 (light transmitting panels). Miami Dade County NOA: (roof), (wall), see special installation instructions, Signature is a registered trademark of Metal Building Components, L.P. Galvalume and Galvalume Plus are registered and protected trademarks of BIEC International, Inc. 2 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

5 PBR PANEL PBR PANEL 12" 36" 1¹ ₄" SECTION PROPERTIES NEGATIVE BENDING POSITIVE BENDING PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo GAUGE (KSI) (PSF) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) * * * Fy is 80-ksi reduced to 60-ksi in accordance w ith the 2001 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members - A All calculations for the properties of PBR panels are calculated in accordance w ith the 2001 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members. 2. Ixe is for deflection determination. 3. Sxe is for bending. 4. Maxo is allow able bending moment. 5. All values are for one foot of panel w idth. The Engineering data contained herein is for the expressed use of customers and design professionals. Along w ith this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along w ith the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. PBR PANEL FASTENER LOCATIONS PANEL ENDS INTERIOR OF PANEL APPLICATION PREVAILING WIND 1. The PBR panel has an unsymmetrical purlin bearing side lap leg. Panel side lap with extended foot to bear on frame. However, where possible, the panel should be lapped against prevailing wind. 2. The above are typical fastener spacings. However, they may not be appropriate for all applications. Consult a professional engineer for use on any specific application. 3. Minimum ¹ ₂ x ³ ₃₂ tape sealer required at panel side laps when used as roof panels. 4. Side lap fasteners are required. Typical spacing is 20 O.C. However, this spacing may not be appropriate for all applications. Consult a professional engineer for use on any specific application. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

6 PBR PANEL ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT. PBR PANEL 29 Gauge (Fy = 60 KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE 2-SPAN 3-SPAN 4-SPAN Gauge (Fy = 60 KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE 2-SPAN 3-SPAN 4-SPAN Gauge (Fy = 50 KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE 2-SPAN 3-SPAN 4-SPAN Gauge (Fy = 50 KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE 2-SPAN 3-SPAN 4-SPAN ) Allow able loads are based on uniform span lengths and Fy = 50 and 60-ksi. 2) LIVE LOAD is limited by bending, shear, combined shear & bending and w eb crippling. 3) does not contain a % increase and does not consider fastener pullout or pullover. 4) Above loads consider a maximum deflection ratio of L/180. 5) The w eight of the panel has not been deducted from the allow able loads. 6) The use of any accessories other than those provided by the manufacturer may damage panels, void all w arranties and w ill void all engineering data. 7) This material is subject to change w ithout notice. Please contact MBCI for most current data. The Engineering data contained herein is for the expressed use of customers and design professionals. Along w ith this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along w ith the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer. 4 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

7 PBR PANEL UL 90 REQUIREMENTS PBR PANEL Construction #30 26 MSG Min. Gauge PBR Panel Over Purlins at 5'- 0 ¹ ₄" O.C. 1. For Class 90 - Panel to purlin connections to be #14 Hex Head with a ⁵ ₈" O.D. washer in a in. pattern. Panel to panel connection to be 20" O.C. with fastener located over each purlin. 2. Purlins - No. 14 MSG min. gauge steel, (55,000 psi min. yield strength.) Construction #79 26 MSG Min. Gauge PBR Panel Over Purlins at 5'- 0 ¹ ₄" O.C. 1. Panel Fasteners - Panel to purlin connections to be #14 Hex Head with a ⁵ ₈" O.D. washer, 6" O.C. in in. pattern. Endlap spacing to be 6 in. O.C. Spacing for panel to panel connection to be 20" O.C. 2. Purlins - No. 16 MSG min. gauge steel. (55,000 psi min. yield strength); or min. H series open web steel joists. Construction # MSG Min. Gauge PBR Panel Over Purlins at 5'- 0 ¹ ₄" O.C. 1. Panel Fasteners - Panel to purlin connections to be x 1" self-drilling Hex Head with a ⁵ ₈" O.D. washer, 12" O.C. Spacing at endlap to be in a in. patterns. Spacing for panel to panel connection to be 20" O.C. with a fastener located over each purlin. 2. Purlins - No. 16 MSG min. gauge steel. (55,000 psi min. yield strength). Construction # MSG Min. Gauge PBR Panel Over Purlins at 5'- 0 ³ ₁₆" O.C. 1. Panel Fasteners - Panel to purlin connections to be 12-14x1" self-drilling Hex Head with a ⁵ ₈" O.D. washer,12" O.C. Spacing at endlap to be in a in. pattern. Spacing for panel to panel connection to be 20" O.C. with a fastener located over each purlin. 2. Building Units - Translucent Panels. 3. Translucent Panel Rib and Purlin Reinforcement - See UL 90 light transmitting panel installation instructions. 4. Purlins - No. 16 MSG min. gauge steel. (55,000 psi min. yield strength). IMPACT RESISTANCE PBR panels carry a Class 4 rating under UL-2218 "Test Standard For Impact Resistance" FIRE RESISTANCE RATING 1. Deck: NC Class A Incline: Unlimited The panel qualifies for a Class A Fire Rating in compliance with Underwriters Laboratories Standard UL-263 when installed over a non-combustible substrate. A Class C Fire Rating will be qualified for over combustible substrate. Look for classification marking on product. CAUTION The above listings are summaries of Construction Numbers. For UL 90 rated roof requirements and complete design information, see the Underwriters Laboratories Building Materials Directory. If you have any questions, call MBCI before proceeding. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

8 PRODUCT CHECKLIST PBR PANEL PBR Panel Ridge Cap Sculptured High Side Eave 8" 12" 36" 1¹ ₄" PBR Panel Maximum Roof Pitch 6:12 Specify Pitch FL-49 2'-6" FL-51 3'-0" 2" Specify Roof Pitch High Eave part at corner to be mitered Specify Left or Right 1³ ₄" FL-17 Flat Ridge/Hip Flashing 11¹ ₂" 11¹ ₂" FL-38 Valley Flashing Standard SPECIFY ANGLE SPECIFY ANGLE Extended 18³ ₄" 11" 2" 2" 11" 45 FL ³ ₄" 45 FL-558 Sculptured Rake 2" Rake part at corner to be mitered. Specify Left or Right 5" 1³ ₄" 1¹ ₄" 1³ ₄" FL-16 Parapet High Eave Parapet Rake Eave Trim 6" 1³ ₄" 5" 6" 3¹ ₂" 5" ⁵ ₈" 5¹ ₂" ³ ₄" Specify Roof Slope FL-874 FL-952 Specify Roof Pitch FL-19 Sculptured Hang-On Gutter 1" 90 - OF ROOF PITCH ³ ₄" DIM. A Sculptured Eave Gutter 1" 3¹ ₂" DIM. A 90 + of ROOF SLOPE Gutter Strap Gutter End FL-893 Specify Roof Slope Gutter part at corner to be mitered. Specify Left or Right OF ROOF PITCH FL-18C 90 + of Specify Roof Slope ROOF SLOPE Gutter part at corner to be mitered. Specify Left or Right. FL-18 Specify Left or Right Specify Gutter part no. FL-18A 6 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

9 PBR PANEL PRODUCT CHECKLIST Inside Corner Trim 4¹ ₂" ³ ₄" Downspouts 3¹ ₂" Corner Trim - Outside 3⁵ ₁₆" 1³ ₄" 4¹ ₂" 1³ ₄" 3¹ ₂" FL-31 - Straight 3⁵ ₁₆" ³ ₄" 1³ ₄" ³ ₄" ³ ₄" 1³ ₄" FL-800 FL-31A - With Kick-Out FL-830 Base Trim (With Sheeting Notch) Base Trim (Without Sheeting Notch) Jamb Trim 3¹ ₄" 2" 1³ ₄" 2" 1³ ₄" 45 2¹ ₂" 1¹ ₄" ¹ ₂" 135 ⁵ ₈" ¹ ₂" 1¹ ₄" FL-72 FL-530 FL-23 Fasteners #17A X 1¹ ₄" Driller LTP Head Trim #4A #3 #4 ¹ ₄"-14 X ⁷ ₈" Lap Tek X 1¹ ₄" Long Life Driller ¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek Non-Reinforced Fiberglass High Strength Fiberglass High Strength AcryLit/U.V. Resistant 1¹ ₄" 1³ ₈" 2¹ ₂" FL-26 Fasteners #43L ¹ ₄"-14 X 1¹ ₄" Long Life Driller with 1¹ ₈"O.D. washer Sealant ¹ ₂" x ³ ₃₂" TRI-BEAD ¹ ₂" x ³ ₃₂" HW-507 Tri-Bead HW-504 Closures Inside HW-455 #44L ¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek with 1¹ ₈"O.D. washer TRIPLE BEAD Triple Bead HW-502 Outside Beveled Inside* HW-456 #14 ¹ ₈ X ³ ₁₆ Stainless Steel Pop Rivet Urethane White TUBE SEALANT 11 OZ. HW-540 NOTE: 25' Per tube at ¹ ₄" bead Other Colors Available Beveled Outside* *Special order - requires two-week lead time SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

10 ATTACHMENT PBR PANEL PBR PANEL ENDLAP ATTACHMENT (SEE DETAIL B) HIGH SIDE ATTACHMENT (6 FASTENERS PER PANEL) SLOPE A A PBR PANEL EAVE ATTACHMENT (6 FASTENERS PER PANEL) INTERMEDIATE PURLIN ATTACHMENT (3 FASTENERS PER PANEL) 6" 20" ROOF 24 WALL PBR PANEL 6 EACH PER PANEL ¹ ₂" X ³ ₃₂" DETAIL "A" DETAIL "B" ¹ ₂" x ³ ₃₂" Sidelap 1. ¹ ₂" X ³ ₃₂" tape sealer must be installed between weather infiltration point and fastener. 2. Install Fastener #4 (¹ ₄"-14 X ⁷ ₈ " Long Life Lap Tek) at 20" O.C. at roof panel side laps and 2 O.C. at wall panel side laps. 3. When possible, install panels such that sidelaps are nested away from prevailing winds. 4. Fastener #4A (¹ ₄"-14 X ⁷ ₈ " Lap Tek) are available as an alternate when long life fasteners are not desired. Endlap 1. Stack 2 continuous layers of ¹ ₂" x ³ ₃₂" tape sealer on top of each other and must be installed between weather infiltration point and fastener. 2. Install Fastener #3 (12-14 X 1¹ ₄" Long Life driller) on each side of major ribs of panel (two fasteners per foot). 3. Fastener #17A (12-14 X 1¹ ₄" driller) are available as an alternate when long life fasteners are not desired. 8 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

11 PBR PANEL SLOPE CONSTRUCTION NO. 542 UL 90 LIGHT TRANSMITTING PANEL INSTALLATION Install roof panels, leaving the light transmitting panel run open, except for lower light transmitting panel run panel. Install tape sealer to panel sidelaps and across panel width as normal. TRI-BEAD LOWER PANEL PURLIN ¹ ₂" x ³ ₃₂" LIGHT TRANSMITTING PANEL SLOPE TRI-BEAD PURLIN Attach light transmitting panels at the low and mid-slope connection to the purlin with nine Fastener #43L (¹ ₄ - 14 x 1¹ ₄" Long Life Driller with 1¹ ₈" O.D. washer) per connection. LOWER PANEL 3L (18 MINIMUM) SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

12 PBR PANEL CONSTRUCTION NO. 542 UL 90 LIGHT TRANSMITTING PANEL INSTALLATION (Continued) Be sure the light transmitting panel sidelaps have complete run of (¹ ₂" x ³ ₃₂") tape sealer between the light transmitting panel and the PBR panel. See Page 8 for lap detail. SLOPE (9 PER PANEL) Fasten light transmitting panel with Fastener #44L (¹ ₄" - 14 x ⁷ ₈" Long Life Lap Tek with 1¹ ₈" O.D. washer) at 10" O.C. down each side lap. PURLIN LOWER PANEL 3L (18 MINIMUM) 4L 10" O.C. LIGHT TRANSMITTING PANEL Install upper metal panel in light transmitting panel run and fasten as at a normal endlap with nine Fastener #3 (12-14 X 1¹ ₄" Long Life driller). 10 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

13 PBU PANEL GENERAL DESCRIPTION 36" 6" ³ ₄" PBU Panel Coverage Width - 36" Minimum Slope - 1:12 Panel Attachment - See page 17 Panel Substrate - Galvalume Gauge - 26 standard - 29, 24 and 22 also available Coatings - Galvalume Plus, Signature 200* and Signature 300* ARCHITECT/ENGINEER INFORMATION 1. PBU panel is a structural roof and wall panel. This panel can be installed directly over purlins or joists. PBU panel is UL 90 rated per construction number PBU panel is recommended for 1:12 or greater roof slopes. 3. Field applied sealant is required at panel sidelaps and endlaps. 4. PBU panel is a through-fastened panel. For proper fastener application, see page 12 and page The information in this manual is believed to be correct and accurate. It should not be used for any specific application without being reviewed by a registered professional engineer. PRODUCT SELECTION CHART GAUGE GALVALUME PLUS SIGNATURE 200* SIGNATURE 300* 22 gauge 24 gauge 26 gauge 29 gauge - Available in any quantity. - Minimum quantity may be required. *See Commercial/Industrial color chart for available colors. Signature is a registered trademark of Metal Building Components, L.P. Galvalume and Galvalume Plus are registered and protected trademarks of BIEC International, Inc. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

14 PBU PANEL PBU PANEL 36" 6" ³ ₄" SECTION PROPERTIES NEGATIVE BENDING POSITIVE BENDING PANEL Fy WEIGHT Ixe Sxe Maxo Ixe Sxe Maxo GAUGE (KSI) (PSF) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) (IN.4/FT.) (IN.3/FT.) (KIP-IN.) 29 60* * * Fy is 80-ksi reduced to 60-ksi in accordance with the 2007 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members - A All calculations for the properties of PBU panels are calculated in accordance with the 2007 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members. 2. Ixe is for deflection determination. 3. Sxe is for bending. 4. Maxo is allowable bending moment. 5. All values are for one foot of panel width. PBU PANEL FASTENER LOCATIONS PANEL ENDS INTERIOR OF PANEL APPLICATION PREVAILING WIND 1. The PBU panel has an unsymmetrical purlin bearing side lap leg. Panel side lap with extended foot to bear on frame. However, where possible, the panel should be lapped against prevailing wind. 2. The above are typical fastener spacings. However, they may not be appropriate for all applications. Consult a professional engineer for use on any specific application. 3. Minimum ¹ ₂ x ³ ₃₂ tape sealer required at panel side laps when used as roof panels. 4. Side lap fasteners are required. Typical spacing is 20 O.C. However, this spacing may not be appropriate for all applications. Consult a professional engineer for use on any specific application. 12 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

15 PBU PANEL PBU PANEL ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT. 29Gauge(Fy=60KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE 2-SPAN 3-SPAN 4-SPAN Gauge(Fy=60KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE 2-SPAN 3-SPAN 4-SPAN Gauge(Fy=50KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE 2-SPAN 3-SPAN 4-SPAN Gauge(Fy=50KSI) SPAN TYPE LOAD TYPE SPAN IN FEET SINGLE 2-SPAN 3-SPAN 4-SPAN ) Allowable loads are based on uniform span lengths and Fy = 50 and 60-ksi. 2) LIVE LOAD is limited by bending, shear, combined shear & bending and web crippling. 3) does not contain a % increase and does not consider fastener pullout or pullover. 4) Above loads consider a maximum deflection ratio of L/180. 5) The weight of the panel has not been deducted from the allowable loads. 6) The use of any accessories other than those provided by the manufacturer may damage panels, void all warranties and will void all engineering data. 7) This material is subject to change without notice. Please contact MBCI for most current data. The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold -Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads If further information or guidance regarding cold-formed design practices is desired SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

16 UL 90 REQUIREMENTS PBU PANEL PBU PANEL Construction #39 26 MSG Min. Gauge PBU Panel over Purlins at 5'- 0 ¹ ₄" O.C. 1. Panel Fasteners - Panel to purlin connections to be #14 self-drilling, Hex Head with a ⁵ ₈" O.D. washer, 6" O.C. Spacing at endlaps to be 6" O.C. Spacing for panel to panel connections to be 12" O.C. 2. Purlins - No. 16 MSG min gauge steel. (55,000 psi min. yield strength) IMPACT RESISTANCE PBU panels carry a Class 4 rating under UL-2218 "Test Standard For Impact Resistance" FIRE RESISTANCE RATING 1. Deck: NC Class A Incline: Unlimited The panel qualifies for a Class A Fire Rating in compliance with Underwriters Laboratories Standard UL-263 when installed over a non-combustible substrate. A Class C Fire Rating will be qualified for over a combustible substrate. Look for classification marking on product. CAUTION The above listings are summaries of Construction Numbers. For UL 90 rated roof requirements and complete design information, see the Underwriters Laboratories Building Materials Directory. If you have any questions, call MBCI before proceeding. 14 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

17 PRODUCT CHECKLIST PBU PANEL PBU Panel Ridge Cap Sculptured High Side Eave 8" 36" 6" ³ ₄" PBU Panel Maximum Roof Pitch 6:12 Specify Pitch FL '-6" FL '-0" 2" Specify Roof Pitch High Eave part at corner to be mitered Specify Left or Right 1³ ₄" FL-17 Flat Ridge/Hip Flashing Valley Flashing Sculptured Rake SPECIFY ANGLE 2" 5" 1¹ ₈" 11¹ ₂" Specify Roof Slope 11¹ ₂" FL-38 Standard SPECIFY ANGLE Extended 18³ ₄" 11" 2" 11" 45 FL ³ ₄" 45 FL-558 2" Rake part at corner to be mitered. Specify Left or Right 1⁷ ₈" 1³ ₄" FL-15 Parapet High Eave Parapet Rake Eave Trim 6" 2" 5" 5 ³ ₄" 3¹ ₂" 5" ⁵ ₈" 5¹ ₂" ³ ₄" Specify Roof Slope FL-874 FL-954 Specify Roof Slope FL-19 Sculptured Hang-On Gutter 1" ³ ₄" 90 - of Roof Pitch 90 + of Roof Pitch DIM "A" Sculptured Eave Gutter 1" 90 + of Roof Pitch 3¹ ₂" DIM "A" Gutter Strap Gutter End FL-893 FL-512B Specify Roof Slope Gutter part at corner to be mitered. Specify Left or Right of Roof Pitch FL-512 Specify Left or Right Specify Gutter Part No. FL-18A SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

18 PRODUCT CHECKLIST PBU PANEL Inside Corner Trim 3" ³ ₄" Downspouts 3¹ ₂" Corner Trim - Outside 3 ⁵ ₁₆" 1¹ ₈" 1¹ ₁₆" 3¹ ₂" 3" FL-31 - Straight 3 ⁵ ₁₆" ³ ₄" ³ ₄" 1¹ ₁₆" 1¹ ₈" ³ ₄" FL-810 FL-31A - With Kick-Out FL-840 Base Trim (With Sheeting Notch) Base Trim (Without Sheeting Notch) Jamb Trim 3¹ ₄" 2" 1³ ₄" 2¹ ₄" 1³ ₄" 45 2¹ ₂" 1" ¹ ₂" 135 ⁵ ₈" ¹ ₂" 1¹ ₄" Fasteners #17A #4A FL-72 FL-530 Fasteners ¹ ₄"-14 X 1¹ ₄" Long Life Driller Sealant ¹ ₂" x ³ ₃₂" HW-507 with 1¹ ₈"O.D. washer ¹ ₂" x ³ ₃₂" #43L Tri-Bead HW-504 TRI-BEAD #44L #3 #4 # X 1¹ ₄" Driller ¹ ₄"-14 X ⁷ ₈" Lap Tek X 1¹ ₄" Long Life Driller ¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek ¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek with 1¹ ₈"O.D. washer ¹ ₈ X ³ ₁₆ Stainless Steel Pop Rivet LTP Non-Reinforced Fiberglass High Strength Fiberglass High Strength AcryLit/U.V. Resistant TRIPLE BEAD Triple Bead HW-502 Urethane White TUBE SEALANT 11 OZ. HW-540 NOTE: 25' Per tube at ¹ ₄" bead Other Colors Available FL-21 Head Trim 2¹ ₂" 1" 1" FL-514A Closures Inside Outside Beveled Inside* HW-459 HW-460 Beveled Outside* *Special order - requires two-week lead time 16 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

19 PBU PANEL ATTACHMENT PBU PANEL ENDLAP ATTACHMENT (SEE DETAIL B) HIGH SIDE ATTACHMENT (6 FASTENERS PER PANEL) SLOPE A A PBU PANEL EAVE ATTACHMENT (6 FASTENERS PER PANEL) 20" O.C. 6" INTERMEDIATE PURLIN ATTACHMENT (3 FASTENERS PER PANEL) 6 EACH PER PANEL ¹ ₂" X ³ ₃₂" PBU PANEL DETAIL "A" DETAIL "B" ¹ ₂" x ³ ₃₂" Sidelap 1. ¹ ₂" X ³ ₃₂" tape sealer must be installed between weather infiltration point and fastener. 2. Install Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) at 20" on center. 3. When possible, install panels such that sidelaps are nested away from prevailing winds. 4. Fastener #4A (¹ ₄"-14 X ⁷ ₈" Lap Tek) are available as an alternate when long life fasteners are not desired. Endlap 1. Stack 2 continuous layers of ¹ ₂" x ³ ₃₂" tape sealer on top of each other and must be installed between weather infiltration point and fastener. 2. Install Fastener #3 (12-14 X 1¹ ₄" Long Life driller) on each side of major ribs of panel (two fasteners per foot). 3. Fastener #17A (12-14 X 1¹ ₄" self-driller) are available as an alternate when long life fasteners are not desired. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

20 PBU PANEL LIGHT TRANSMITTING PANEL INSTALLATION SLOPE Install roof panels, leaving the light transmitting panel run open, except for lower light transmitting panel run panel. Install tape sealer to panel sidelaps and across panel width as normal. TRI-BEAD LOWER PANEL PURLIN ¹ ₂" x ³ ₃₂" LIGHT TRANSMITTING PANEL SLOPE TRI-BEAD Attach light transmitting panels at the low and mid-slope connection to the purlin with six Fastener #43L (¹ ₄ - 14 x 1¹ ₄" Long Life Driller with 1¹ ₈" O.D. washer) per connection. PURLIN LOWER PANEL 3L (12 MINIMUM) 18 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

21 PBU PANEL LIGHT TRANSMITTING PANEL INSTALLATION (Continued) Be sure the light transmitting panel sidelaps have complete run of (¹ ₂" x ³ ₃₂") tape sealer between the light transmitting panel and the PBU panel. See Page 17 for lap detail. SLOPE (6 PER PANEL) Fasten light transmitting panel with Fastener #44L (¹ ₄" - 14 x ⁷ ₈" Long Life Lap Tek with 1¹ ₈" O.D. washer) at 10" O.C. down each side lap. PURLIN LOWER PANEL 3L (12 MINIMUM) 4L 10" O.C. LIGHT TRANSMITTING PANEL Install upper metal panel in light transmitting panel run and fasten as at a normal endlap with six Fastener #3 (12-14 X 1¹ ₄" Long Life driller). SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

22 TYPICAL DETAILS Ridge PBR & PBU PANELS PBR or PBU RIDGE CAP 1'-0" 6" 6 EACH PER PANEL PBR or PBU PANEL PEAK PURLIN ¹ ₂" X ³ ₃₂" PBR or PBU RIDGE CAP (4) PER RIDGE CAP (SEE DETAIL A) 6 EACH PER PANEL PBR or PBU PANEL PEAK PURLIN ¹ ₂" X ³ ₃₂" 1. When ordering ridge caps, specify roof slope. Refer to MBCI price pages for maximum slope for each ridge cap. 2. Install ¹ ₂" X ³ ₃₂" tape sealer across full with of ridge cap on both sides. Tape sealer must be installed between weather infiltration point and fasteners. 3. Install ¹ ₂" X ³ ₃₂" tape sealer to the sidelap of the ridge cap that will lap onto adjacent ridge cap. Tape sealer must be installed between weather infiltration point and fasteners. 4. Install Fastener #3 (12-14 X 1¹ ₄" Long Life driller) on both sides of major ribs (two per foot). 5. Install four Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) in each ridge cap sidelap. Place (1) one Lap Tek in high rib on each side of the ridge cap centerline and one in line with purlin fastener on each side of ridge line. 20 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

23 PBR & PBU PANELS TYPICAL DETAILS High Side Eave OUTSIDE EACH MAJOR RIB ¹ ₂" x ³ ₃₂" SCULPTURED HIGH SIDE EAVE PBR or PBU PANEL 6 EACH PER PANEL EAVE STRUT 12" O.C. OUTSIDE EACH MAJOR RIB SCULPTURED HIGH SIDE EAVE ¹ ₂" x ³ ₃₂" OUTSIDE CLOSURE 6 EACH PER PANEL PBR or PBU PANEL EAVE STRUT 1. Install outside closure, with ¹ ₂" X ³ ₃₂" tape sealer top and bottom, across width of PBR or PBU panels. 2. Install Sculptured High Side Eave to PBR or PBU panels at each major rib with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek). Sculptured high side eave trim should overhang outside closures ¹ ₂" - 1". 3. Attach front face of sculptured high side eave trim to wall with fasteners or cleat as required for wall substrate. 4. Trim laps should be approximately 3" with sufficient amount of Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) to hold lap together. Apply bead of urethane sealant between trim at 3" lap. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

24 TYPICAL DETAILS Hip PBR & PBU EACH MAJOR RIB ¹ ₂" x ³ ₃₂" HIP FLASHING BEVELED OUTSIDE CLOSURE FASTENER #12A SDS EACH PURLIN) HIP PLATE 6 EACH PER PANEL PURLIN HIP EACH MAJOR RIB PBR or PBU PANEL BEVELED OUTSIDE CLOSURE ¹ ₂" x ³ ₃₂" PURLIN FASTENER #12A SDS EACH PURLIN) HIP PLATE 1. Bevel cut and install PBR or PBU panels to follow bevel of hip. 2. Install beveled outside closures to panels, with ¹ ₂" x ³ ₃₂" tape sealer top and bottom, following bevel of hip. Beveled closures must be special ordered and require a two week lead time. 3. Install hip flashing to panel at each major rib with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek). Hip flashing should overlap outside closures ¹ ₂"-1". 4. Trim laps should overlap approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) to hold lap together. 22 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

25 PBR & PBU PANELS TYPICAL DETAILS Valley TRI-BEAD FIELD CUT INSIDE CLOSURE VALLEY FLASHING TRIPLE BEAD 6 EACH PER PANEL VALLEY PLATE 4¹ ₂" FOR STANDARD VALLEY 9" FOR EXTENDED VALLEY PBR or PBU PANEL PBR or PBU PANEL PURLIN VALLEY TRIM BEVEL CUT PANEL TO MATCH SLOPE OF VALLEY TRIM (12) PER PANEL TRIPLE BEAD TRI-BEAD FIELD CUT INSIDE CLOSURE 1. For valleys 30' or less in length, use standard valley trim. Valleys over 30' in length require extended valley trim. 2. Apply Triple Bead tape sealer to valley trim parallel to the slope of the valley. Lower edge of tape sealer should be 4¹ ₂" from center of valley for standard valleys and 9" from the center of the valley for extended valleys. 3. Install high rib section of inside closure that has been field cut from standard 3'-0" straight closure. Place the cut closure square with the rib of the panel. Install Tri-Bead tape sealer to top of inside closure prior to laying panel edge down on top of the cut closure. The Triple Bead tape with proper fastener sequence will seal the minor ribs of the panel that are between the major ribs. 4. Bevel cut PBR or PBU panels to fit slope of valley and install to valley with Fastener #3 (12-14 X 1¹ ₄" Long Life driller) at on center. Fasteners must be installed through the closures and into Triple Bead tape sealer. 5. Trim laps should overlap approximately 6" with a bead of urethane sealant in between. Do not rivet valley laps together. If laps gap open, install Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) into each side of water diverter while holding lap tightly together. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

26 TYPICAL DETAILS Gutter PBR & PBU PANELS INSIDE CLOSURE GUTTER STRAP ¹ ₂" x ³ ₃₂" PBR or PBU PANEL INSULATION SCULPTURED EAVE GUTTER WALL PANEL (6 EACH PER PANEL) FASTENER #14 POP RIVET (2 PER TRIM PIECE) EAVE STRUT DOUBLE FACED TAPE ¹ ₂" x ³ ₃₂" INSIDE CLOSURE PBR or PBU PANEL GUTTER STRAP INSULATION SCULPTURED HANG ON GUTTER WALL PANEL DOUBLE FACED TAPE 6 EACH PER PANEL FASTENER #14 POP RIVET (2 PER TRIM PIECE) ¹ ₂" x ³ ₃₂" BOX PANEL CAP TRIM EAVE STRUT Eave Gutter 1. Attach gutter to eave strut with two Fastener #14 pop rivets per section. 2. Install inside closures to top leg of gutter with ¹ ₂" x ³ ₃₂" tape sealer top and bottom. 3. Install PBR or PBU panel with Fastener #3 (12-14 X 1¹ ₄" Long Life driller) on each side of major ribs (two fasteners per foot). Fasteners must be installed up slope from inside closures. 4. Gutter laps should be approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of pop rivets to hold lap together. 5. Install gutter straps 3'-0" on center with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) fasteners at each end. Hang-on Gutter 1. Attach Box Panel Cap Trim to top of eave strut with pop rivet #14 (two per 10'-0" section). 2. Install inside closure on top of Box Panel Cap Trim with ¹ ₂" x ³ ₃₂" tape sealer top and bottom of closure. 3. Install PBR or PBU panels with Fastener #3 (12-14 X 1¹ ₄" Long Life driller)on each side of the major ribs (two fasteners per foot). Fasteners must be installed up slope from inside closures. 4. Attach gutter to roof panels with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) at each end. 5. Gutter laps should be approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of Fastener #14 (pop rivets) to hold lap together. 6. Install gutter straps 3'-0" on center with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) at each end. 24 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

27 PBR & PBU PANELS SIDELAP ATTACHMENT (SEE DETAIL A) PBR or PBU PANEL ¹ ₂" X ³ ₃₂" INSIDE CLOSURE EAVE TRIM 12" O.C. OUTSIDE CLOSURE WALL PANEL TYPICAL DETAILS Eave Trim (6 EACH PER PANEL) FASTENER #14 (2 PER TRIM PIECE) EAVE STRUT PBR or PBU PANEL INSULATION DOUBLE FACED TAPE ¹ ₂ " X ³ ₃₂" (SEAL TO AT EAVE AND SIDELAP) (6 EACH PER PANEL) ¹ ₂" X ³ ₃₂" INSULATION WITH VINYL FOLDED BACK AT EAVE DOUBLE FACED TAPE FASTENER #14 (2 PER TRIM PIECE) 20" O.C. EAVE STRUT ¹ ₂ " X ³ ₃₂" INSIDE CLOSURE ¹ ₂" X ³ ₃₂" DETAIL "A" EAVE TRIM 12" O.C. 1. Install eave trim to structure with two pop rivets per section. 2. Install inside closures along top leg of eave trim with ¹ ₂" x ³ ₃₂" tape sealer top and bottom. 3. Install PBR or PBU panel with Fastener #3 (12-14 X 1¹ ₄" Long Life driller) on each side of major ribs (2 fasteners per foot) allowing panel to overhang 1¹ ₂" plus wall thickness. Fasteners must be installed up slope from inside closures. 4. Attach front face of eave trim to wall with fasteners or cleat as required for wall substrate. 5. Trim laps should overlap approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) to hold lap together. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

28 TYPICAL DETAILS Rake PBR & PBU PANELS 12" O.C. ¹ ₂" X ³ ₃₂" PBR or PBU PANEL ¹ ₂" X ³ ₃₂" 6" O.C. FIELD BEND 1" LEG FASTENER #17A EACH SUPPORT RAKE ANGLE SCULPTURED RAKE TRIM PURLIN 12" O.C. OUTSIDE CLOSURE BEGINNING ON MODULE FINISHING OFF MODULE Beginning on Module 1. Install ¹ ₂" x ³ ₃₂" tape sealer to top of PBR or PBU panel rib. 2. Install rake trim to PBR or PBU panel rib with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Teks) at 1'-0" on center. 3. Attach front face of rake trim to wall with fasteners or cleat as required for wall substrate. 4. Trim laps should overlap approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of Fastener #14 pop rivets to hold lap together. Finishing off Module 1. Cut and field bend a 1" leg on PBR or PBU Panel. 2. Install ¹ ₂" x ³ ₃₂" tape sealer to top of PBR or PBU panel. 3. Install rake trim to PBR or PBU panel with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Teks) at 6" on center. 4. Attach front face of rake trim to wall with fasteners or cleat as required for wall substrate. 5. Trim laps should overlap approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of pop rivets to hold lap together. 26 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

29 PBR & PBU PANELS TYPICAL DETAILS Parapet High Side Eave PARAPET HIGH SIDE EAVE MAJOR RIB OUTSIDE CLOSURE WALL PANEL GIRT INSIDE CLOSURE ¹ ₂" X ³ ₃₂" PBR or PBU PANEL 6 EACH PER PANEL PURLIN WALL MAJOR RIB PARAPET HIGH SIDE EAVE FLASHING GIRT 6 EACH PER PANEL ¹ ₂" X ³ ₃₂" PBR or PBU PANEL OUTSIDE CLOSURE PURLIN 1. Install outside closure, with ¹ ₂" x ³ ₃₂" tape sealer top and bottom, across width of PBR or PBU panels. 2. Install parapet high side trim to PBR or PBU panels at each major rib with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Teks). Trim should overhang outside closures ¹ ₂" - 1". 3. Attach top leg of parapet high side trim to wall with fasteners as required for wall substrate. 4. Trim laps should overlap approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) to hold lap together. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

30 TYPICAL DETAILS Parapet Rake PBR & PBU PANELS PARAPET RAKE TRIM 12" O.C. ¹ ₂" X ³ ₃₂" PBR or PBU PANEL 6" O.C. INSIDE CLOSURE FASTENER #14 POP RIVET (2 PER TRIM PIECE) FIELD BEND 1" LEG FASTENER EACH PURLIN 2" X ANGLE PURLIN Beginning on Module 1. Install ¹ ₂" x ³ ₃₂" tape sealer to top of PBR or PBU panel rib. 2. Install parapet rake trim to PBR or PBU panel rib with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Teks) at 1'-0" on center. 3. Attach top leg of parapet rake trim to 2" X angle with Fastener #14 pop rivet. Elevate horizontal leg of parapet trim slightly, to provide for positive drainage of water. 4. Trim laps should overlap approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) to hold lap together. Finishing off Module 1. Cut and bend a 1" leg on PBR or PBU Panel. 2. Install ¹ ₂" x ³ ₃₂" tape sealer to top of PBR or PBU panel. 3. Install parapet rake trim to PBR or PBU panel with Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Teks) at 6" on center. 4. Attach top leg of parapet rake trim to 2" X angle with pop rivets. Elevate horizontal leg of parapet trim slightly, to provide for positive drainage of water. 5. Trim laps should overlap approximately 3" with a bead of urethane sealant in between. Install a sufficient amount of Fastener #4 (¹ ₄"-14 X ⁷ ₈" Long Life Lap Tek) to hold lap together. 28 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

31 PBR & PBU PANELS PBR or PBU PANEL TYPICAL DETAILS Corner OUTSIDE CORNER TRIM 2 O.C. WALL GIRT OUTSIDE CORNER DETAIL INSIDE CORNER TRIM WALL GIRT PBR or PBU PANEL 2 O.C. INSIDE CORNER DETAIL 1. Install corner trim with Fastener #4 (¹ ₄ - 14 X ⁷ ₈" Long Life Lap Tek) fastener 2'-0" O.C. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

32 TYPICAL DETAILS Corner Box PBR & PBU PANELS GUTTER STRAPS 3'-0" O.C. PBR or PBU PANEL SCULPTURED EAVE GUTTER (MITERED) SCULPTURED RAKE TRIM (MITERED) PBR WALL PANEL GUTTER END CORNER TRIM SCULPTURED EAVE GUTTER (MITERED) GUTTER END SCULPTURED EAVE RAKE TRIM (MITERED) 1. Gutter and rake trim must be ordered with a left and right mitered end. To determine left or right, stand on ground and look toward eave. Roof slope must also be specified. 30 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

33 PBR & PBU PANELS TYPICAL DETAILS Base PBR or PBU PANEL DOUBLE-FACED TAPE INSULATION 2" x BASE ANGLE FASTENER 3'-0" O.C. ¹ ₄" MIN. PBR or PBU PANEL INSULATION 2" x BASE ANGLE FASTENER 3'-0" O.C. DOUBLE-FACED TAPE BASE TRIM 1. Wall with vinyl insulation, pull back fiberglass approximately pull over end and staple. Apply double face tape to base angle and stick insulation to it before applying panel and fastening with Fastener #3 (¹ ₄ - 14 x 1¹ ₄" Long Life Driller), six each per panel. 2. Should base trim be desired, temporarily attach trim to base angle with two Fastener #14 pop rivets until panels are installed. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

34 TYPICAL DETAILS Head / Jamb PBR & PBU PANELS WALL GIRT FASTENER EACH GIRT DOOR EACH GIRT JAMB TRIM PBR or PBU PANEL JAMB FASTENER EACH GIRT PBR or PBU PANEL 3'-0" O.C. PURLIN FASTENER 12" O.C. HEAD TRIM FASTENER 12" O.C. DOOR HEAD HEAD 1. Install Jamb and Head Trim with pop rivets as required to support flashing during panel installation. 32 SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25, 2010

35 PBR & PBU PANELS INSTALLATION GUIDELINES I. Pre-Order II. A. Prior to ordering panels, all dimensions should be confirmed by field measurement. Job Site Storage and Handling A. Check the shipment against the shipping list. B. Damaged material must be noted on bill of lading. C. Panels should be handled carefully. A spreader bar of appropriate length is recommended for hoisting. D. Check to see that moisture has not formed inside the bundles during shipment. If moisture is present, panels should be wiped dry, then restacked and loosely covered so that air can circulate between the panels. III. Application Checklist A. Check substructure for proper alignment and uniformity to avoid panel distortion. B. Periodic check of panel alignment is crucial to proper panel installation. C. For proper appearance, ribs should line up at hips, valleys and ridges. D. Panels should be cut on ground to minimize cut filings on roof. Keep panels clean during installation. Do not allow panels to come into contact with water runoff from lead, copper or graphite. SUBJECT TO CHANGE WITHOUT NOTICE SEE FOR CURRENT INFORMATION EFFECTIVE JANUARY 25,

36 For current information, visit our Website at Houston, TX West Hardy P.O. Box Houston, TX Adel, GA 1601 Rogers Road P.O. Box 1107 Adel, GA Atlanta, GA 2280 Monier Avenue P.O. Box Atlanta, GA Atwater, CA 550 Industry Way P.O. Box 793 Atwater, CA Dallas, TX 1804 Jack McKay Blvd. P.O. Box 1210 Ennis, TX Indianapolis, IN 1780 McCall Drive P.O. Box 657 Shelbyville, IN Jackson, MS 201 Apache Drive P.O. Box Jackson, MS Lubbock, TX 5711 East FM-40 P.O. Box Lubbock, TX Memphis, TN 300 Highway 51 North P.O. Box 366 Hernando, MS Oklahoma City, OK 7000 S. Eastern Avenue P.O. Box Oklahoma City, OK Omaha, NE 1011 Ellison Avenue Omaha, NE Phoenix, AZ 660 South 91st Avenue P.O. Box 739 Tolleson, AZ Richmond, VA 801 South Avenue P.O. Box 239 Colonial Heights, VA Rome, NY 6168 State Route 233 P.O. Box 4141 Rome, NY Salt Lake City, UT 1155 West 2300 North P.O. Box Salt Lake City, UT San Antonio, TX 8677 I-10 East P.O. Box 69 Converse, TX Litho in U.S.A /5M

PBR & PBU PANELS. Technical/Installation Information

PBR & PBU PANELS. Technical/Installation Information PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS

More information

Retro-R DESIGN/INSTALLATION INFORMATION

Retro-R DESIGN/INSTALLATION INFORMATION Retro-R DESIGN/INSTALLATION INFORMATION IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM TO

More information

Residential Pricing Guide

Residential Pricing Guide Guide TABLE OF CONTENTS Panels 5V Crimp Slimline 2 4 Accessories Flat Sheets Coils V-Groove Soffit Ridge Caps Roof Jacks Touch-up Paint Insulation Slimline Rib Cover Closure Strips Tube Sealant 6 6 7

More information

NuRoof Retrofit Systems. Technical/Installation Information

NuRoof Retrofit Systems. Technical/Installation Information Retrofit Systems Technical/Installation Information INTRODUCTION If your roof is causing problems due to leaks, high maintenance costs and low energy efficiency, the MBCI NuRoof Retrofit System is the

More information

5V CRIMP. Technical/Installation Information

5V CRIMP. Technical/Installation Information 5V CRIMP Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL OCMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE

More information

BattenLok HS. Technical/Installation Information

BattenLok HS. Technical/Installation Information BattenLok HS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ROOFING SYSTEM. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM

More information

Central Seam Plus. Central-Loc

Central Seam Plus. Central-Loc Central Seam Plus Central-Loc Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 3" 3" " or 18" COVERAGE " or 18" COVERAGE Central Seam Plus Field seamed Central-Loc Snaps together

More information

Designer Series. Technical/Installation Information

Designer Series. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Designer Series WALL SYSTEM. MBCI MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE

More information

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information Table of ontents Product Page No. Product Page No. Panel Information Profile...PST-2 Panel Overview...PST-2 Flashing Profiles Eave...PST- Extended Eave...PST- leat...pst- Stile Starter...PST- Box Gutter...PST-

More information

The Experts in Retrofit Design. Retrofit Solutions. Retro-R SSR NuRoof NuWall

The Experts in Retrofit Design. Retrofit Solutions. Retro-R SSR NuRoof NuWall The Experts in Retrofit Design Retrofit Solutions Retro-R SSR NuRoof NuWall Retrofit Solutions by MBCI MBCI has experience in retrofitting existing buildings proven with millions of square feet of successfully

More information

ShadowRib Metal Wall Panel INSTALLATION GUIDE

ShadowRib Metal Wall Panel INSTALLATION GUIDE Metal Wall Panel INSTALLATION GUIDE IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ROOFING SYSTEM. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE

More information

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5

More information

FW-120. Technical/Installation Information

FW-120. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE S. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE

More information

SECTION METAL ROOF PANELS

SECTION METAL ROOF PANELS SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof

More information

Western States 7/8 Corrugated

Western States 7/8 Corrugated Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key

More information

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

Prior to ordering and installing materials, all dimensions should be verified by field measurements. Important Information The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects

More information

29 Gauge. Technical/Installation Information

29 Gauge. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE 29 GAUGE LOW PROFILE PANELS PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED

More information

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV

More information

ShadowRib. Design/Installation Information

ShadowRib. Design/Installation Information ShadowRib Design/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ROOFING SYSTEM. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM

More information

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK A. 1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb

More information

TRIAD CORRUGATED METAL, INC.

TRIAD CORRUGATED METAL, INC. TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial

More information

PIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components

PIPE. Central Texas Largest Distributor.  Structural Steel, Pipe and Metal Building Components Central Texas Largest Distributor Structural Steel, Pipe and Metal Building Components PIPE Waco Location P.O. Box 154485 913 South Loop Dr. Waco Texas 76705 Local - 254-754-2611 Bryan Location 9401 E.

More information

S BI COM P ON E NT CA T ALOG

S BI COM P ON E NT CA T ALOG SBI METAL BUILDINGS & COMPONENTS S BI COM P ON E NT CA T ALOG Date: 03 / 16 / 2017 COMMERCIAL PRODUCTS Commercial Panels and Trim Cee, Zee, Eave Struts, Angle, Channel, and Clips Accessories FT 0 1 2 3

More information

LokSeam. Technical/Installation Information

LokSeam. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ROOFING SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,

More information

PRE-ENGINEERED METAL BUILDING SYSTEM

PRE-ENGINEERED METAL BUILDING SYSTEM PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,

More information

MultiLok-24 Guide Specifications conforming to C.S.I. standards. A Division of ASC Profiles

MultiLok-24 Guide Specifications conforming to C.S.I. standards. A Division of ASC Profiles MultiLok-24 Guide Specifications conforming to C.S.I. standards A Division of ASC Profiles AEP SPAN MultiLok-24 Guide Spec i fi ca tions MANUFACTURER - AEP SPAN 5100 East Grand Avenue, Dallas, TX 75223,

More information

RIB PANEL INSTALLATION

RIB PANEL INSTALLATION GOLDIN METALS, INC. www.goldinmetals.com 12440 SEAWAY ROAD Mailing Address: 14231 SEAWAY ROAD, SUITE 7000 GULFPORT, MS 39503 (228) 896-6216, Ext. 230 FAX (228) 896-4873 4400 PETERS ROAD P.O. BOX 700 HARVEY,

More information

Central Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼

Central Texas Metal Roofing Supply Co., Inc 36 NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼ 36" 1 2 " 6" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 26 26 26 24 24 24 24 TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD CHANNEL GUARD CHANNEL GUARD GALVALUME

More information

Architectural. Technical/Installation Information

Architectural. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE This information is designed to assist you in product selection, detailing and application. MBCI is prepared and staffed to provide professional assistance

More information

Central Snap. Condition Details C SNAPDETAILS

Central Snap. Condition Details C SNAPDETAILS Central Snap Condition Details D C SNAPDETAILS150612.2 The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing, Inc. is a 100% employee-owned

More information

Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 5V Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES ½" 24" COVERAGE Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_5V_180201 The men

More information

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation

More information

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations LIP-LO Table of ontents Product Page No. Product Page No. Panel Information lip-loc Panel Profile... PL-2 Panel Overview... PL-2 Flashing Profiles Eave... PL- leat... PL- Box Gutter... PL- Box Gutter End...

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

Stile. Spanish Tile Installation Guide

Stile. Spanish Tile Installation Guide Stile Spanish Tile Installation Guide IMPORTANT INFORMATION THE APPLICATION AND DETAIL DRAWINGS IN THIS MANUAL ARE STRICTLY FOR ILLUSTRATION PURPOSES AND MAY NOT BE APPLICABLE TO ALL BUILDING DESIGNS OR

More information

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM SECTION 13 34 21 - STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. The structural retrofit roof sub-framing system will provide support for a new metal roofing system constructed

More information

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

FW-120 and ILPanels. Technical/Product Information

FW-120 and ILPanels. Technical/Product Information FW-120 and ILPanels Technical/Product Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE FW-120 AND IL PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED

More information

ALLMET CONTINENTAL INSTALLATION GUIDE

ALLMET CONTINENTAL INSTALLATION GUIDE ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental

More information

INSTALLATION GUIDE.

INSTALLATION GUIDE. INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten

More information

FOR FIELD USE PLEASE DISTRIBUTE TO THE ERECTION CREW

FOR FIELD USE PLEASE DISTRIBUTE TO THE ERECTION CREW COVER INSTRUCTIONS FOR INSTALLING NBS CLASSIC ROOF FOR FIELD USE PLEASE DISTRIBUTE TO THE ERECTION CREW WATERLOO, IN 305 Industrial Parkway Waterloo, IN 46793 Phone: 260-837-7891 Fax: 260-837-7384 SWANSEA,

More information

Industry Standard Terms & Definitions Of The Steel Deck Institute

Industry Standard Terms & Definitions Of The Steel Deck Institute Industry Standard Terms & Definitions Of The Steel Deck Institute A specialized set of jargon to describe common terms used by manufacturers and other professionals associated with the usage of Steel Deck

More information

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH 1 2 " 1 24" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 5 Vee GALVALUME 24 26 3/8 95.00 PRICE PER SQ. PRICE PER LINEAR FOOT PANEL PRICING: 1. Price per Square is based on 26 3/8 sheet

More information

Guardian. Standing Seam Roof System. Manual THIS MANUAL REPLACES ALL PREVIOUS MANUALS EFFECTIVE JANUARY 1, 2006 / JC & JEN

Guardian. Standing Seam Roof System. Manual THIS MANUAL REPLACES ALL PREVIOUS MANUALS EFFECTIVE JANUARY 1, 2006 / JC & JEN Guardian Standing Seam Roof System Erection Manual THIS MANUAL REPLACES ALL PREVIOUS MANUALS / JC & JEN IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE GUARDIAN

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (0) 3-87 (562) 699-03 www.icc-es.org ESR-23 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00 00 THERMAL

More information

Double-Lok. Technical/Installation Information

Double-Lok. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE DOUBLE-LOK ROOFING SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO ENSURE

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM #

238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM # 238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM # DESCRIPTION SELLING PRICE UOM 238T 238T Seam Cap 24

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE

More information

SECTION STEEL DECKING

SECTION STEEL DECKING SECTION 05 31 00 STEEL DECKING SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Refer to Section 05 36 00, COMPOSITE METAL DECKING for floor

More information

The Olympia Difference

The Olympia Difference The Olympia Difference Valued Customer, Thank you for choosing Olympia Steel Buildings as the solution to your building needs. You can be confident that the Olympia team of professionals will provide you

More information

Code Compliance Research Report CCRR-0228

Code Compliance Research Report CCRR-0228 Code Compliance Research Report CCRR-0228 Issue Date: 05-09-2017 Renewal Date: 05-11-2018 Revision Date: 06-23-2017 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 40 00 Roofing and Siding

More information

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers. SECTION 05 31 33 - STEEL FORM DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification

More information

SL175 Panel Technical Data Guide

SL175 Panel Technical Data Guide Description SL175 is a integral snap-lock standing seam roofing panel used on commercial and residential applications. The panel is factory formed in continuous lengths up to 60-0 long. Attachment to either

More information

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation Hip Detail Hip Detail STANDARD Mineral fibre insulation ENHANCED Hip flashing with 150mm sealed butt straps Panels site cut to suit rake angle Apex dam (Ref: LP1/A) Rake cut profiled filler sealed top

More information

MBCI Weathertightness WARRANTIES

MBCI Weathertightness WARRANTIES MBCI Weathertightness WARRANTIES WEATHERTIGHTNESS WARRANTIES MBCI believes if the building owner has to file a claim against the roof manufacturer s Weathertightness Warranty, then someone has not done

More information

TABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles

TABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles TABLE OF ONTENTS Product Page No. Product Page No. Panel Information Profi les...pim-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3

More information

Guardian-Lok. Standing Seam Roof System THIS MANUAL APPLIES TO GUARDIAN-LOK SYSTEMS. GUARDIAN-LOK REQUIRES PANEL SIDELAPS TO BE MECHANICALLY SEAMED.

Guardian-Lok. Standing Seam Roof System THIS MANUAL APPLIES TO GUARDIAN-LOK SYSTEMS. GUARDIAN-LOK REQUIRES PANEL SIDELAPS TO BE MECHANICALLY SEAMED. Standing Seam Roof System Erection Manual THIS MANUAL APPLIES TO GUARDIAN-LOK SYSTEMS. GUARDIAN-LOK REQUIRES PANEL SIDELAPS TO BE MECHANICALLY SEAMED. THIS MANUAL REPLACES ALL PREVIOUS MANUALS / JC & JEN

More information

CS-100 Guide Specifications

CS-100 Guide Specifications MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification

More information

General. 2. Design. 3. Anchor Bolts And Foundations. 4. Drawings. 5. Structural Framing. 6. Roof Covering Nucor Classic Roof Panel

General. 2. Design. 3. Anchor Bolts And Foundations. 4. Drawings. 5. Structural Framing. 6. Roof Covering Nucor Classic Roof Panel The following Nucor Building Systems Specification Guide provides the owner or design professional a detailed description of all standard Nucor Building Systems (NBS) products. This guide is designed to

More information

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers. SECTION 05 31 13 STEEL FLOOR DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

200 / 300 SERIES PANELS COLD STORAGE

200 / 300 SERIES PANELS COLD STORAGE CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES

More information

PRE-ENGINEERED METAL BUILDINGS

PRE-ENGINEERED METAL BUILDINGS PRE-ENGINEERED METAL BUILDINGS CONTENTS Section 1: General Section 2: Structural Steel Design Section 3: Basic Material Specifications Section 4: Structural Framing Section 5: Roof and Wall Covering Section

More information

SECTION METAL BUILDING SYSTEMS

SECTION METAL BUILDING SYSTEMS SECTION 13 3419 PART 1 GENERAL 1.01 SECTION INCLUDES A. Manufacturer-engineered, shop-fabricated structural steel building frame. B. Insulated Metal wall and roof panels including gutters and downspouts.

More information

CATALOG STEEL BUILDING

CATALOG STEEL BUILDING CATALOG STEEL BUILDING 2 Why Metal Depots 9 Carports 14 Windows TABLE OF CONTENTS 2 Build Your Dream 10 Light-Gauge Structural 14 Roll-Up Doors 3 Handyman Series 11 Light-Transmitting Panels 15 Sealants

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

SL150 Guide Specification

SL150 Guide Specification SL150 Guide Specification This is a suggested guide specification for metal roofing projects where the SL150 panel system is applicable. Questions regarding applicability should be discussed with Union

More information

Metafor Panel System Installation Guide

Metafor Panel System Installation Guide Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE

More information

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

INSTRUCTIONS AND GUIDELINES

INSTRUCTIONS AND GUIDELINES INSTRUCTIONS AND GUIDELINES NOISEBLOCK TM MODULAR PANEL SYSTEMS ENCLOSURES & PRESSURIZED PLENUMS PLANNING HINTS & NOTES: 1. Review the Kinetics Noise Control submittal and installation drawings and bill

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

Residential, 26 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

Residential, 26 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D Product Evaluation Report REED S METAL, INC. Residential, 26 Ga. Roof Panel over 15/32 Plywood Florida Product Approval # 12725.2 R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D Category: Roofing

More information

ARCHITECTURAL DESIGN GUIDE

ARCHITECTURAL DESIGN GUIDE CFR INSULATED METAL ROOF PANEL ARCHITECTURAL DESIGN GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS INTRODUCTION........................................................2

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

Built to Last a Lifetime

Built to Last a Lifetime Built to Last a Lifetime Welcome to Lincoln 2 This brochure will introduce you to Lincoln Steel Buildings from the ground up starting with the framing of the building all the way to the roof and finally

More information

SHEET METAL ROOF TEST REPORT

SHEET METAL ROOF TEST REPORT SHEET METAL ROOF TEST REPORT Introduction The time tested performance of the double lock standing seam and batten seam metal roofing is demonstrated by thousands of squares successfully installed by SMACNA

More information

Guide Specification SDP 200

Guide Specification SDP 200 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION SECTION 07320 TWO-PIECE TAPERED MISSION CLAY ROOFING TILE PART 1 GENERAL 1.01 SECTION INCLUDES A. Formed clay roofing tiles, complete with components and other required accessories

More information

Ponderay Newsprint-TMP Waterlock + Usk, Washington. Maximum Building Value

Ponderay Newsprint-TMP Waterlock + Usk, Washington. Maximum Building Value Ponderay Newsprint-TMP Waterlock + Usk, Washington Maximum Building Value A-Frame + 608 tons of steel + 101,136 sq. ft. If you re going to build something, it ought to last. Cemex-Clinker Storage Building

More information

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein. SECTION 10530 - EXTRUDED ALUMINUM WALKWAY COVERS PART I - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division

More information

Guidelines for

Guidelines for Page1 Guidelines for Weather Tightness Warranty For Standing Seam Metal Panels General Today s metal roofing industry is faced with growing demand for warranties that help it compete with other types of

More information

1 1/2" SSR. FABRAL The pursuit of excellence since 1967

1 1/2 SSR. FABRAL The pursuit of excellence since 1967 1 1/2" SSR Detail Manual and Estimate Guide 16" 1 1 2" PROPER STORAGE When moisture remains in contact with Galvanized panels in the absence of freely circulating air, white, black or dark gray corrosion

More information

europanel installation guide horizontally laid panel

europanel installation guide horizontally laid panel europanel installation guide horizontally laid panel A 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing face is consistent

More information

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax: Brava Spanish Tile Installation Manual Brava Roof Tile Phone: 319-338-5706 Fax: 319-343-1038 www.bravarooftile.com This document includes the recommended and suggested installation procedures for Brava

More information

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall

More information

Professional Engineering Services. The Brand of Choice

Professional Engineering Services. The Brand of Choice The Brand of Choice Nucor Building Systems, a division of Nucor Corporation, is one of the most flexible and diverse building manufacturers in operation today. Nucor Corporation is a Fortune 500 Company,

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

Shaftwall and Area Separation Wall Systems.

Shaftwall and Area Separation Wall Systems. Shaftwall and Area Separation Wall Systems www.marinoware.com Marino\WARE S Fire Rated Wall Systems Quality that takes you to the top. Marino\WARE created its CT Shaftwall System, to be a flexible shaftwall

More information

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. GulfRib Roof Panel over 15/32 Plywood Florida Product Approval #11651.23 R3 Florida Building Code 2017 Per Rule 61G20-3 Method:

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

Central Span. Product Guide 16" COVERAGE HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

Central Span. Product Guide 16 COVERAGE HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES Central Span Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 2" 16" COVERAGE Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_CentralSpan_180201

More information

UNA-CLAD Metal Roofing Systems Application Guide

UNA-CLAD Metal Roofing Systems Application Guide UNA-CLAD Metal Roofing Systems Application Guide UC-3 Double-Lock Architectural Series UC-4 No-Clip Architectural Series UC-6 Double-Lock Structural Series UC-14 Snap-Lock Standing Seam Series March 22,

More information

DUGOUT MODEL (4 POST) 10 x 24 SPECIFICATIONS

DUGOUT MODEL (4 POST) 10 x 24 SPECIFICATIONS DUGOUT MODEL (4 POST) 10 x 24 SPECIFICATIONS Dimensions: Roof Dimensions 10-0 x 24 Column Dimensions (center to center) 6-7 x 22-9 Minimum Clearance 7-6 Minimum Clearance @ Front ±9-2 Roof Pitch 2:12 pitch

More information

Ultra-Dek. Technical/Installation Information

Ultra-Dek. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Ultra-Dek ROOFING SYSTEM. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS

More information

SIERRA MODEL 12 X 24 SPECIFICATIONS

SIERRA MODEL 12 X 24 SPECIFICATIONS SIERRA MODEL 12 X 24 SPECIFICATIONS Dimensions: Roof Dimensions 12-0 x 24-0 Column Dimensions (center to center) 9-0 x 21-0 Minimum Clearance 8-0 Shed Roof 1:12 pitch Square Feet Under Roof 288 Columns

More information

INSTALLATION MANUAL Heritage Series

INSTALLATION MANUAL Heritage Series INSTALLATION MANUAL Heritage Series STEEL ROOF PANELS HEAD OFFICE 1418 Michael St., Ottawa, ON K1B 3R2 WATS LINE: 1 800-267-0860 TEL.: 1 613-746-3206 FAX: 1 613-746-0445 Contents Page Introduction, Storage..

More information

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM - --- -- ----..-------~------------------------------------ GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION 07415 REROOFING ADJUSTABLE FRAMING SYSTEM PART 1 - GENERAL 1.01 SCOPE A.

More information

StrongSeam SSFF1 Panel

StrongSeam SSFF1 Panel StrongSeam SSFF1 Panel Installation Manual May 2016 12 TO 24 COVERAGE CLIP OFFSET STRIATED PANEL (2 STRIATION BEADS ON PANEL) 0.875 0.9375 26 ga. & 24 ga. UL90 #529 UL2218 Class IV/Impact UL790 Class A/Fire

More information