1 Exam Prep Roofing Practice Exam 12
|
|
- Benjamin Hardy
- 6 years ago
- Views:
Transcription
1 1 Exam Prep Roofing Practice Exam ccording to the NR, when applying double-layer underlayment to the substrate, the drip-edge metal should be Sandwiched between the layers Placed below the felt along the rake and above the felt along the eave Placed below the felt along the rake and below the felt along the eave Placed above the felt along the rake and below the felt along the eave 2. When installing wood shingles over space sheathing, adjacent courses should be offset a minimum of how many inches? The recommended gage for stainless steel counter flashing is Wood blocking in HVHZ areas shall be in accordance with WW -26 W -9 SYP -26 WP Gutter straps with an 18 inch girth made of stainless steel should be 1/8 X 1 1/8 X 2 1/4 X 1 1/2 3/16X 1 6. When installing gravel stops over PV flashing on roof slopes of less than 1 in 12 Nail the flashing every 3 inches Prime the bottom side of the flashing Prime the top side of the flashing Prime both sides of the flashing 1
2 7. Number 1 Straight-split 18 inch by 3/8 inch shingles with an 8 inch exposure has an approximate coverage of how many square feet per square? When flashing a valley according to Roofing and onstruction Estimating, the contractor should install which of the following in the valley centerline? 36 inch wide roll roofing, 50 pound or heavier 18 inch wide 26 gage galvanized metal 2 layers of 30 pound asphalt-saturated felt 18 inch wide roll roof mineral side up 9. ccording to Roofing and onstruction Estimating, the drip edge should be installed Under the felt along the eaves and under the underlayment along the rakes Over the felt along the eaves and under the underlayment along the rakes Over the felt along the eaves and over the underlayment along the rakes Under the felt along the eaves and over the underlayment along the rakes 10. The minimum R-value approach establishes the thermal resistance for a tapered roof insulation system by determining the R-value of the tapered material at the Thickest point in the tapered system layout Thinnest point in the tapered system layout verage point in the tapered system layout ny point in the tapered system layout 11. Water exerts a pressure of per foot of depth? 8.33 pounds per square foot 8.33 pounds per cubic foot 62.4 pounds per square foot 62.4 pounds per cubic foot 12. Which is not a common subcategory of thermoplastic membranes? EPM KEE TPO PV 2
3 13. ccident prevention is the responsibility of the Employer Prime contractor Roofing contractor uilding Official 14. The sealing out of water under pressure is called Hydrostatic head Hydrokenisis locking head Force majeure 15. ccording to the NR, fasteners should penetrate at least how far into wood planks? 1 inch 3/4 inches 1/2 inch 1/4 inch 16. To pass the test, the weight of the test-cut components must be within what percent plus or minus of the specified requirements? The starter course for wood shingles according to Roofing and onstruction Estimating should overhang beyond the eaves fascia 1 inch 1.5 inches 1.75 inches 2 inches 18. allasted EPM systems are limited to a height of 32 feet 48 feet 60 feet 80 feet 19. gutter is 3 inches by 4 inches. The total cross-sectional area is 14 inches 12 inches 7 inches 49 inches 3
4 20. ccording to the NR to resist 20 feet of head, the number of coal-tar plies required is The tapered systems is 6 inches at the thickest point and 2 inches at the thinnest point. Using the verage R- Value approach, the R-value of the tapered system is Valued at how many inches of thickness? When installing random-width slates, offset joints in adjacent courses at least 1/2 foot 3 inches 2 inches 1 inch 23. aution should be used when applying roofing materials below what temperature? 40 degrees entigrade 50 degrees Fahrenheit 50 degrees entigrade 40 degrees Fahrenheit 24. The rise and run for a 5/12 pitch is 5 in 12 8 in in in The lowest temperature at which vapors above a volatile combustible substance ignite in air when exposed to a flame is Flashpoint Ignition last point Torch time 4
5 26. ccording to the Walker's uilding Estimator's Reference ook, 15 pound felt, 100 square feet installed in 3 plies with an 8 percent waste is square feet. 1, When test cutting UR systems, test cut an area at least 12 inches by 24 inches 24 inches by 36 inches 36 inches by 42 inches 10 inches by 42 inches 28. Roofing and onstruction Estimating recommends when a chimney is over two feet, install a Fabricated galvanized metal saddle 5 X 5 metal pan flashing strip Wooden dormer extending at least 6 inches either side of the chimney 26 gage metal apron 29. PE roofing may be used with all of the following except Mechanical screws Heat-welds oal-tar pitch Stainless steel nails 30. Termination bar should be mechanically fastened to the deck every 6 inches 12 inches 24 inches 3 feet 31 The total length of valley for The Exam House is Less than 125 feet etween 125 and 130 feet etween 130 and 135 feet More than 135 feet 32. Which of the following may be used with EPM systems? Seam caulk oal tar sphalt Oil-based roofing cement 5
6 33. When fastening half-inch wood structural panels in HVHZ of 120 miles per hour in Exposure "", the roofer should use 6 penny nails 6 inches on center 8 penny nails 6 inches on center 10 penny nails 6 inches on center 12 penny nails 8 inches on center 34. The highest ultimate wind speed possible for roward ounty is miles per hour EVT is defined as the temperature at which the viscosity of roofing asphalt is Explosive t flash point Emits yellow smoke 125 s 36. Which fastener is recommended for treated wood for maximum corrosion resistance? opper Galvanized lued Stainless 37. The 1 Exam Prep Office uilding requires 400 pounds of gravel per 100 square feet. Including the air conditioning areas but not the trium, the tons of gravel required are Less than 51 etween 51 and 55 etween 55 and 60 More than attens are required on roof slopes of 6 in 12 and less 8 in 12 and greater 10 in 12 7 in 12 and greater 6
7 39. plywood index number of 32/16 means The plywood is 32 inches by 16 inches The plywood will span 32 inches between rafters and 16 inches between floor joists The plywood will span 16 inches between rafters and 32 inches between floor joists The plywood will hold 32 pounds and 16 ounces 40. EPM membranes should never be installed with which of the following? old process Heat seal Plastic cement and dead level allast 41. Weepholes should be what size in diameter? 1/8 inch 1/4 inch 1/2 inch 3/4 inch 42. Stainless steel rectangular gutter with an 18 inch girth should be what gage? Type III asphalt may be used on roof slopes or less? 1/4 inch per foot 1/2 inch per foot 3/4 inch per foot 1 inch per foot 44. The minimum slope for standing seam copper roofing is inches per foot One of the drawbacks to using mineral surfaced roll roofing is The sun will cause deterioration problems after 3 years The granules will wash away over time Tears and rips are hard to repair small tear will affect a large deck area
8 46. ccording to Roofing onstruction and Estimating, a 54 inch horizontal wide chimney requires wood saddle at the upper side of the chimney copper flash at the low side of the chimney galvanized iron cricket at the upper side of the chimney metal apron on the terminal side of the cricket 47. Metal chutes at an angle of more than 45 degrees from the horizontal shall have openings not to exceed how many inches in height? One layer of 3 foot by 4 foot 2 inch Insulation board is required for the Office uilding. Specifications require 6 nails per board. Nails cost $18.75 per hundred. Including the air conditioning areas but not the trium, the total cost for the nails only is Less than $2,000 etween $2,000 and $2,200 etween $2,200 and $2,400 More than $2, When applying polymer-modified asphalt roofing, the contractor should use Low kettle temperatures etailed torch kits oal tar roof cements sphalt roof cements 50. ccording to NR, a gutter bracket made of galvanized steel should measure 1/8 inch by 1 inch 3/16 inches by 1 inch 3/8 inch by 1 inch 1/4 inch by 1 1/2 inches 51. ccording to the NR, woven valleys are generally limited to roof slopes 4 in 12 and greater 5 in 12 and greater 6 in 12 and greater 9 in 12 and less 8
9 52. To limit the effects of thermal expansion, the practical maximum gutter length is 40 feet 50 feet 75 feet 100 feet 53. Which of the following is not a single-ply roofing system? PE PV SP PI 54. ontinuous means in lengths not to exceed 10 feet 12 feet 20 feet 24 feet 55. Kettle temperature should be maintained at less than how many degrees below flash point? roof deck underside should be inspected to determine all except its Type Slope ttachment pplicability 57. The required gauge for galvanized gravel stop with a 4 inch profile is? Metal coping single lap joints should be inches minimum width
10 59. When applying modified bitumen membrane sheets directly to combustible substrates such as wood decks, NR recommends Not using a torch Using a torch Nailing the rosin paper Not using rosin paper 60. s a general rule, most gutters are usually any of the following inches wide except The number of plies required for 20 feet of head is Reglets cut in masonry should be a minimum of how many inches in depth? The linear expansion for mild steel per 100 degrees is ccording to Roofing onstruction and Estimating, 1 X 2 wood battens 4 feet long should have ends separated by how many inches? 1 inch 2 inches 1/2 inch 3/4 inches 65. Ladders must extend how many feet above the upper landing?
11 66. When installing wood shingles over spaced sheathing, the drip edge should extend 1/2 inches 3/4 inches 1 inch 1.5 inches 67. Type II flat asphalt may be used on slopes up to.5 in 12 1 in /2 in 12 2 in The total length of hip and ridge for The Exam House is Less than 160 etween 160 and 170 etween 170 and 180 More than Roof slopes of less than 6 in 12 use 8 foot battens with 1/2 inch drain slots 4 foot double battens with drain slots every 4 feet 8 foot battens with 1/2 inch drain slots 4 foot battens with 1/2 inch drain slots between ends 70. The maximum temperature for the application of Type 2 asphalt for mop applications Is 350 degrees F 375 degrees F 400 degrees F 425 degrees F 71. Pressure exerted on a surface by a column of water is Hydrokenesis Hydrostatic Non-hydrostatic Hydropulsive 72. Mission tile weighs approximately how many pounds per square? ,000 1,300 11
12 73. The total squares of shingles required for The Exam House is Less than 44 etween 44 and 47 etween 47 and 50 More than 50 28' 14' Z ' 30' THE EXM HOUSE 22' 20' 14' 12
13 OFFIE UILING T 60' -I, II 1 _.c. _1 lci a' TYR 36' 8' TYP. i TRIUM 36' 22' 16'
14 NSWER KEY 12 1 NR Steep-slope Roof Systems, Roofing onstruction and Estimating SMN rchitectural Sheet Metal Manual 7 th Edition Florida uilding ode, Test Protocols SMN rchitectural Sheet Metal Manual 7 th Edition Roofing onstruction and Estimating Roofing onstruction and Estimating Roofing onstruction and Estimating 67 9 Roofing onstruction and Estimating NR Membrane Roof Systems, NR Waterproofing Manual, NR Membrane Roof Systems, ode of Federal Regulations, (OSH) (b) 14 Roofing onstruction and Estimating NR Steep-slope Roof Systems, Roofing onstruction and Estimating Roofing onstruction and Estimating Roofing onstruction and Estimating Roofing onstruction and Estimating NR Waterproofing Manual, NR Membrane Roof Systems, Roofing onstruction and Estimating NR Membrane Roof Systems, Walker's uilding Estimator's Reference NR rchitectural Metal Flashing, Walker's uilding Estimator's Reference Roofing onstruction and Estimating Roofing onstruction and Estimating Roofing onstruction and Estimating Roofing onstruction and Estimating
15 31 Walker's uilding Estimator's Reference X 1.6 = Roofing onstruction and Estimating Florida uilding ode, uilding, 2010 Table Florida uilding ode, uilding, 2010 Page NR Membrane Roof Systems, NR rchitectural Metal Flashing, Walker's uilding Estimator's Reference 468 X LX W= 100 X WPS + 2, X 46 X 20 M X 134 X 80 M X 60 X 36 M X 36 X 22 M- MR 100 X ,000 = Roofing onstruction and Estimating Roofing onstruction and Estimating Roofing onstruction and Estimating Roofing onstruction and Estimating SMN rchitectural Sheet Metal Manual, 7 th Edition NR Membrane Roof Systems, Walker's uilding Estimator's Reference Roofing onstruction and Estimating Roofing onstruction and Estimating ode of Federal Regulations, (OSH) (b) 48 Walker's uilding Estimator's Reference 1124 # X L X W+ Layer X # Nail per board X X134 X 80 M X 46 X 20 M X 60 X 36 M X 36 X 22 M- MR 12 X X = $2, NR Membrane Roof Systems, NR rchitectural Metal Flashing,
16 51 NR Steep-slope Roof Systems, SMN rchitectural Sheet Metal Manual, 7 th Edition Roofing onstruction and Estimating SMN rchitectural Sheet Metal Manual NR Membrane Roof Systems, NR rchitectural Metal Flashing, NR rchitectural Metal Flashing, SMN rchitectural Sheet Metal Manual NR Membrane Roof Systems, Roofing onstruction and Estimating Roofing onstruction and Estimating SMN rchitectural Sheet Metal Manual, 7th Edition Roofing onstruction and Estimating Roofing onstruction and Estimating ode of Federal Regulations, (OSH) Roofing onstruction and Estimating Roofing onstruction and Estimating Walker's uilding Estimator's Reference = Roofing onstruction and Estimating NR Membrane Roof Systems, NR rchitectural Metal Flashing, Roofing onstruction and Estimating Walker's uilding Estimator's Reference = X 30 M X 12 M X 12 M+ 4 2 X 14 X 12 M+ MR X = 45.9 = 46 16
1 Exam Prep. Roofing Practice Exam 8
1 Exam Prep Roofing Practice Exam 8 1. The minimum slope for thermoset single-ply roofing is 1/2:12 1/3:12 1/4:12 1:12 2. Flashing must be primed on both sides when the roof slope is less than 1:12 2:12
More information1 Exam Prep. Roofing Practice Exam 10
1 Exam Prep Roofing Practice Exam 10 1. haracteristics of modified polyurethane are all except? Weather resistance olor retention High UV resistance Fire resistance 2. The total squares of shingles required
More information1 Exam Prep. Roofing Practice Exam 5
1 Exam Prep Roofing Practice Exam 5 1. Mineral surfaced cap sheets should be unrolled and allowed to relax for how long? Eight hours Until soft and pliable Four hours Until flat 2. Roll roofing material
More information1 Exam Prep. Roofing Practice Exam 9
1 Exam Prep Roofing Practice Exam 9 1. Roof assemblies are fire rated in accordance with STM E 100 and UL 790 UL108 and STM E 790 The building official UL 790 and STM E 108 2. The underlayment and composition
More information1 Exam Prep. NRCA Membrane Roof Systems Questions
1 Exam Prep NR Membrane Roof Systems Questions 1. The preferred method of installing rigid insulation board to cementitious wood-fiber roof decks is? Spot mopping lind nailing Loose laid dhesion to the
More informationROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION
ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION SECTION 07320 TWO-PIECE TAPERED MISSION CLAY ROOFING TILE PART 1 GENERAL 1.01 SECTION INCLUDES A. Formed clay roofing tiles, complete with components and other required accessories
More informationROOF ASSEMBLIES CHAPTER 9
CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION
More informationROOFING STUDY GUIDE ARCHITECTURAL SHEET METAL
ROOFING STUDY GUIDE ARCHITECTURAL SHEET METAL PRACTICE TEST ONE 1. It is recommended that base fleshings be applied over a cant and be extended up the wall a minimum of. A. 6 inches B. 8 inches C. 10 inches
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More informationCity of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017
City of Republic Community Development Department Residential Roofs REVISION DATE: JANUARY 2017 A residential roof permit is required for new roofs and for replacement roofs when the replacement area is
More informationZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -# Sunrise, Florida Phone
12 ZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -#43-307 Sunrise, Florida 33322 Phone 305-345-3793 E-Mail: peterizara@hotmail.com COURSE MATERIALS ROOFING COURSE WITH UPDATED MATERIALS
More informationOREGON ROOF CONSULTING - ROOF INSPECTION FORM
Oregon CCB: 199121 PO Box 220190, Milwaukie, OR 97222 Washington License: OREGORC871MR OREGON ROOF CONSULTING - ROOF INSPECTION FORM General Roof Conditions: NA = Not Applicable Debris on Roof Physical
More informationSLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]
[Change these specifications as needed. Use this sample proposal at your own risk. This is a simple, general proposal and is not meant to be a comprehensive proposal for all situations or projects. If
More informationRoofing City of Owatonna BUILDING DEPARTMENT
Roofing City of Owatonna BUILDING DEPARTMENT 507-444-4370 www.ci.owatonna.mn.us This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code, City of Owatonna
More informationROOF ASSEMBLIES CHAPTER 9
CHAPTER 9 ROOF ASSEMBLIES > SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Pursuant to ORS 215.730; if
More informationROOF ASSEMBLIES CHAPTER 9
CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION
More informationC. Jointing of Exterior Vertical Surfaces. Section D. The Secretary of the US Department of the Interior s Standards for Rehabilitation.
PART 1: GENERAL 1.01 Scope Of Standard A. This standard provides general guidance concerning the specific preferences of the University of Texas at Austin for roofing systems. B. UT recognizes that project
More informationSECTION BATTEN SEAM COPPER ROOFING
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 07 61 16 BATTEN SEAM COPPER ROOFING SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph as required
More informationROOFING APPLICATION STANDARD (RAS) No. 118 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Counter Battens Only
ROOFING APPLICATION STANDARD (RAS) No. 118 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Counter Battens Only 1. 2. Scope This application standard covers the procedures for installation
More informationROOFING APPLICATION STANDARD (RAS) No. 120 MORTAR AND ADHESIVE SET TILE APPLICATION
ROOFING APPLICATION STANDARD (RAS) No. 120 MORTAR AND ADHESIVE SET TILE APPLICATION 1. Scope This application standard covers the procedures for installation of mortar or adhesive set roof tile systems.
More informationFORTIFIED Home High Wind. Bronze New Roof Requirements
THE DECK (PREP MATERIAL, FASTENING) THE ROOF DECK SEALING THE ROOF DECK All existing roof cover and flashings shall be removed; deck shall be a clean, workable surface free from debris. Damaged or rotten
More informationUpdate In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING
Section 07 10 00 ROOFING AND WATERPROOFING Page 07 10 00-1 1. GENERAL REQUIREMENTS A. Indicate applicable American Society for Testing and Materials (ASTM) specification in this section. 01. Fire resistance
More informationSection STRAIGHT BARREL MISSION ROOFING TILE PART 1 - GENERAL 1.1 SUMMARY
This Guide Specification is intended to be used in preparation of specifications for a particular project, or as the basis for an office master specification. In either case, the Guide Specification must
More informationROOF ASSEMBLIES CHAPTER 9
CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION
More informationROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies, and
More informationROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies, and
More informationROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies, and
More informationDIVISION 7 THERMAL AND MOISTURE PROTECTION
DIVISION 7 THERMAL AND MOISTURE PROTECTION UCSC Campus Standards Handbook Waterproofing Standards 07100 1 SECTION 07100: WATERPROOFING STANDARDS A. Guarantee 1. Provide a guarantee on Contractor's letterhead
More informationINSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS System Two: Direct Deck & Counter Battens Only
ROOFING APPLICATION STANDARD (RAS) No. 118 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS System Two: Direct Deck & Counter Battens Only 1. Scope: This application standard covers the procedures
More informationSECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):
SECTION 07320 CLAY BARREL TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02072 - Removals. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials
More informationSECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".
SECTION 07311 ASPHALT SHINGLE ROOFING SYSTEMS Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". PART 1 GENERAL 1.1 SECTION INCLUDES A. Granule surfaced asphalt shingle
More informationSECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal.
SECTION 07320 CLAY BARREL TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02072 - Removals. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials
More informationScope. Definitions. For definitions of terms used in this application standard, refer to ASTM 1079 and the Florida Building Code, Building.
ROOFING APPLICATION STANDARD (RAS) No. 119 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Horizontal Battens Only (Preformed Metals With Edge Returns) 1. Scope This application standard
More informationSECTION TEMPORARY ROOFING MEMBRANE INSTALLATION. A. Areas of the roof deck for asbestos abatement.
PART 1 GENERAL 1.01 APPLICATIONS SECTION 07500 TEMPORARY ROOFING MEMBRANE INSTALLATION A. Areas of the roof deck for asbestos abatement. B. Areas of the roof deck exposed to the structural roof deck substrate.
More informationM.C.A. Superior Clay Roof Tile
This Guide Specification is intended to be used in preparation of specifications for a particular project, or as the basis for an office master specification. In either case, the Guide Specification must
More informationCHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies and rooftop
More informationSRP-AirOutshield ROOF Issued:
SECTION 07276: Breathable Underlayment Guide Specification This specification is a guide only and may need editing for the specific intended application. It is the responsibility of the design professional
More informationShingle Asphalt Asbestos-cement Slate Wood, edge-grain Aluminum. Roll Roofing Mineral-surface 19" selvage edge Lowest Mineral-surface
ROOFING MATERIALS Roofing or roofing materials can be said to have two basic purposes. Primarily, a building is roofed to protect the structure and its contents from the effects of weather. Secondary to
More informationVerea Spanish S Roof Tile Installation Guide
Verea Spanish S Roof Tile Installation Guide IDENTIFICATION OF ROOF AREAS RIDGE HIP FIELD OF ROOF RAKE (left) EAVE VALLEY GABLE END HEAD WALL SIDE WALL RAKE (right) DISCLAIMER NOTICE It is important to
More informationSECTION COMMON WORK RESULTS FOR THERMAL AND MOISTURE PROTECTION
PART 1 GENERAL SECTION 07 05 00 COMMON WORK RESULTS FOR THERMAL AND MOISTURE PROTECTION 1.1 ROOFING A. General: 1. Work shall comply with all local, state, and federal fire and safety regulations. Equipment
More information1 Exam Prep Tabs Roofing Construction & Estimating Tabs and Highlights
1 Exam Prep Tabs Roofing Construction & Estimating Tabs and Highlights These 1 Exam Prep Tabs are based on Roofing Construction and Estimating by Daniel Atcheson, 1995. Each 1 Exam Prep Tabs sheet has
More informationSAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016
PART 1: GENERAL 1.01 Scope Of Standard 1.02 Reference Standards 1.03 Quality Control A. This standard provides general guidance concerning the specific preferences of the Sam Houston State University for
More informationEVALUATION REPORT Boral Roofing /MonierLifetile 7575 Irvine Center Drive Suite 100 Irvine, CA
EVALUATION REPORT Boral Roofing /MonierLifetile 7575 Irvine Center Drive Suite 100 Irvine, CA. 92618 EXTERIOR RESEARCH & DESIGN, LLC. 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245
More information1 Exam Prep NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012 Tabs and Highlights
1 Exam Prep NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012 Tabs and s These 1 Exam Prep Tabs are based on the National Roofing Contractors Association (NRCA) manual listed below: Metal Panel
More informationUFGS (June 2005) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-07 32 14 (April 2006) -------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-07321 (June 2005) UNIFIED FACILITIES GUIDE SPECIFICATIONS References
More informationC. All roofs shall be installed according to manufacturers guidelines. Corrections due to workmanship shall be at contractors expense.
PART 1: GENERAL 1.01 Scope Of Standard 1.03 Reference Standards 1.04 Quality Control A. This standard provides general guidance concerning the specific preferences of the Sam Houston State University for
More informationROOFING. A. National Roofing Contractors Association (NRCA) Roofing Manuals
070000 ROOFING Cornell s Design and Construction Standards provide mandatory design constraints and acceptable or required products for all construction at Cornell University. These standards are provided
More informationSECTION COPPER STANDING SEAM ROOFING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 61 16 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph as required and
More informationDIVISION 07 - THERMAL & MOISTURE PROTECTION
DIVISION 07 - THERMAL & MOISTURE PROTECTION DESIGN CRITERIA General Design Requirements: 1. When designing roof access ladders and stairways to roof shall not be alternating tread type. 2. Provide 18 gauge
More informationPresents. Roofing Basics
Presents Roofing Basics Terminology Tile: A roof tile may be curved or flat piece of baked (at times glazed) clay or a synthetic material. It is the basic block used in covering roofs, walls, and floors.
More informationUNIVERSITY OF MISSOURI Division 07 Thermal and Moisture Protection Roofing:
Roofing: 1. Materials used for moisture protection will comply with specifications contained in the appropriate American Society for Testing and Material standards (ASTM). 2. General roof specification
More informationDistributed by: BEST MATERIALS LLC Ph: , Fax:
Distributed by: BEST MATERIALS LLC Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.bestmaterials.com Email: Sales@BestMaterials.com SECTION 07321 COMPOSITE ROOF TILE PART 1 GENERAL 1.1 SECTION INCLUDES
More informationCHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL 1501.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies, and
More information1 Exam Prep NRCA Roofing Manual: NRCA Roofing Manual: Membrane Roof Systems 2011 Tabs and Highlights
1 Exam Prep NRCA Roofing Manual: NRCA Roofing Manual: Membrane Roof Systems 2011 Tabs and s These 1 Exam Prep Tabs are based on the National Roofing Contractors Association (NRCA) manual listed below:
More informationWVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION
075000 ROOFING SYSTEMS PART 1 - GENERAL 1.1. Any deviation from the following instructions must be approved during design by WVU Facilities Management Personnel. 1.2. DEFINITIONS A. ASTM American Society
More informationSECTION ROOF AND DECK INSULATION
SECTION 07 22 00 ROOF AND DECK INSULATION SPEC WRITER NOTES: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Follow recommendations of National Roofing Contractors
More informationSSL-175. Specifications
SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES
More informationSECTION CONCRETE ROOFING TILES ARCHITECTURAL SPECIFICATIONS VANDE HEY RALEIGH ARCHITECTURAL ROOF TILE
SECTION 07322 CONCRETE ROOFING TILES ARCHITECTURAL SPECIFICATIONS VANDE HEY RALEIGH ARCHITECTURAL ROOF TILE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including
More informationThe Alabama Building Commission has adopted the 2006 International Energy Conservation Code as the State Energy Conservation Code
SECTION 07 20 00 THERMAL PROTECTION SCOPE OF WORK This Section includes building wall, floor and ceiling insulation, and roofing. QUALITY ASSURANCE For all new construction projects and renovation projects
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com Page2 INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationSECTION BUILT-UP BITUMINOUS WATERPROOFING
SECTION 07 12 00 BUILT-UP BITUMINOUS WATERPROOFING SPEC WRITER NOTE: Delete any item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION: This section
More informationClassic and NB Tile Counter Batten and Batten
Classic and NB Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationMAGNUM. I N S P E C T I O N S Inc. ROOF Walked on roof, crawled attic where accessible.
NAME: DATE: October 6, 2006 METHOD OF INSPECTION: ROOF Walked on roof, crawled attic where accessible. ADDRESS: MAIN ROOF COVERING SECONDARY ROOF COVERING Cement Tile: Strip Shingle: XX Tar and Gravel:
More informationSECTION CONCRETE TILE ROOFING. A. American Society for Testing and Materials (ASTM):
SECTION 07324 CONCRETE TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786)315-2590
More informationTESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS
TESTING APPLICATION STANDARD TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS 1. Scope 1.1 This Protocol covers procedures for testing mechanically attached, prefabricated,
More informationTESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS
TESTING APPLICATION STANDARD (TAS) No. 104-95 TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS 1. Scope 1.1 This Protocol covers procedures for testing mechanically attached,
More information2014 Advanced FBC Fifth Edition Chapter 15 Florida Specific Review
2014 Advanced FBC Fifth Edition Chapter 15 Florida Specific Review Mark Zehnal, CPRC Florida Roofing & Sheet Metal Contractors Association FRSA Director of Technical Services 2012 International Building
More informationROOFING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR SELF-ADHERED UNDERLAYMENTS FOR USE IN DISCONTINUOUS ROOF SYSTEMS
ROOFING APPLICATION STANDARD (TAS) No. 103-95 TEST PROCEDURE FOR SELF-ADHERED UNDERLAYMENTS FOR USE IN DISCONTINUOUS ROOF SYSTEMS 1. Scope 1.1 This Protocol covers procedures for testing self-adhering,
More informationSECTION Tile Roof Guideline. B. "Pan" Tile: Clay tile on the underlayment, convex in shape.
SECTION 07 32 13 Tile Roof Guideline PART 1 GENERAL 1.1 RELATED DOCUMENTS A. The drawings and general provisions of the contract, including General and Specific Conditions, and Division 1 (General Requirements)
More information2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES 1.. 3. Scope
More informationSECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):
SECTION 07324 CONCRETE TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials
More informationSUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:
IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:
More informationLight-Metal Roof Edge, Raised
NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationTEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS
TESTING APPLICATION STANDARD (TAS) No. 104-95 TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS Scope 1.1 This Protocol covers procedures for testing mechanically attached,
More informationInstallation Guide. Mission Tile. Distributed by: BEST MATERIALS LLC, Phoenx AZ
RPM ROOFING Installation Guide Mission Tile Distributed by: BEST MATERIALS LLC, Phoenx AZ 602-272-8128 800-474-7570 www.bestmaterials.com Table of Contents OVERVIEW...1 CAUTION...1 DISCLAIMER...1 PRODUCT
More informationRoof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details S1.0 Safety Anchor Plan Building 709 Bull Street Columbia, 1 10/13 T-1 (Title Page)
More informationProud of its Heritage, Preparing for its Future
TUSTIN Proud of its Heritage, Preparing for its Future USER GUIDE FOR THE REROOFING OF BUILDINGS Revised August 2013 PURPOSE This user guide describes the City of Tustin s requirements regarding reroofing
More informationSECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):
SECTION 07324 CONCRETE TILE ROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 07600 - Flashing and Sheet Metal. 1.02 REFERENCES A. American Society for Testing and Materials
More informationDL-200. Specifications
DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01
More informationEngineering Services Program
Product Evaluation Engineering Services Program The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International Building
More informationSTUDY GUIDE. For the REGISTERED ROOF OBSERVER (RRO ) EXAM. Prepared By RRO Examination Development Task Force
STUDY GUIDE For the REGISTERED ROOF OBSERVER (RRO ) EXAM Prepared By RRO Examination Development Task Force RCI, Inc. 1500 Sunday Drive Ste 204 Raleigh, NC 27607 800-828-1902 919-859-0742 RRO Study Guide
More informationRoof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan
More informationEVALUATION REPORT Tarco Roofing One Information Way, Suite 225 Little Rock, AR DESCRIPTION: Tarco Roof Underlayments
EVALUATION REPORT Tarco Roofing One Information Way, Suite 225 Little Rock, AR 72202 EXTERIOR RESEARCH & DESIGN, LLC. 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243
More informationInterim Logbook ROOFER
Interim Logbook ROOFER Department of Advanced Education and Skills Apprenticeship and Trades Certification Division Note to Apprenticeship Applicants This form can only be used to record hours and skills
More informationBrava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:
Brava Spanish Tile Installation Manual Brava Roof Tile Phone: 319-338-5706 Fax: 319-343-1038 www.bravarooftile.com This document includes the recommended and suggested installation procedures for Brava
More informationBattenless. Installation Guide BATTENLESS INSTALLATION GUIDE 1
Battenless Installation Guide BATTENLESS INSTALLATION GUIDE 1 This manual provides general guidelines and procedures relating to the estimating and installation of Varitile roof products. It is not a training
More informationA. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.
DELTA -VENT S Vapor Permeable (Breathable) Roof Underlayment Division 7 Thermal and Moisture Protection PART 1 GENERAL 1.1 SUMMARY A. This Section provides information regarding vapor permeable roof underlayment
More informationSHEET METAL ROOF TEST REPORT
SHEET METAL ROOF TEST REPORT Introduction The time tested performance of the double lock standing seam and batten seam metal roofing is demonstrated by thousands of squares successfully installed by SMACNA
More informationINSTALLATION GUIDE.
INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten
More informationPATIO COVERS BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement PATIO COVERS BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the basic information
More informationEVALUATION REPORT Boral Roofing 7575 Irvine Center Drive Suite 100 Irvine, CA
EVALUATION REPORT Boral Roofing 7575 Irvine Center Drive Suite 100 Irvine, CA. 92618 EXTERIOR RESEARCH & DESIGN, LLC. 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243
More informationMETAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS
METAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS Building contractors are always looking for installation methods that will provide them with savings on labor and materials expenses. Here are some important
More informationMINERAL SURFACE CAP SHEET
Please read the entire document before purchasing and installing any of these products USa SBS UnderlaYment Roofing Underlayment SBS mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection
More informationROOF MITIGATION STRUCTURE EVALUATION FORM. For Single Family Residential Re-Roof Effective October 1, 2007 (Revised February 2, 2018)
ROOF MITIGATION STRUCTURE EVALUATION FORM For Single Family Residential Re-Roof Effective October 1, 2007 (Revised February 2, 2018) Check One Value of home does not exceed $300,000 based on insured value
More informationInstallation Guide. Titan Slate. Rev102606
Installation Guide Titan Slate Rev102606 Titan Manufacturing 200 bella citta blvd. Davenport, fl 33897 Phone: (920) 716-1411 Fax: (866) 601-4395 www.titanroofsystems.com This document includes the recommended
More informationRoofing Policy for Commercial Buildings
Building Permits & Inspection Division General Information: (916) 875-5296 www.building.saccounty.net Full Service Center 827 7th Street, Room 102 Sacramento, CA 95814 M-F 8:30am - 4:30pm Bradshaw Center
More information