Firestopping Submittal Package

Size: px
Start display at page:

Download "Firestopping Submittal Package"

Transcription

1 Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Manufacturer's Representative: Rectorseal - Technical Services Ph (713) * (800)

2 Table of Contents Product Approvals... 1 Certificate of Compliance... 2 Track-Safe Datasheet... 8 HW-D HW-D HW-D HW-D HW-D

3 APPROVALS FOR BIO FIRESHIELD PRODUCTS Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived from one or more of these model codes. Bio FireShield products and systems meet the through-penetration firestopping requirements of all of these codes. ICC International Code Council; International Building Code ICBO International Code of Building Officials; Uniform Building Code SBCCI..... Southern Building Code Congress International; Standard Building Code BOCA..... Building Official and Code Administrators International; National Building Code CABO..... Council of American Building Officials (coordinating agency between ICBO, SBCCI and BOCA) NBCC..... National Building Code of Canada NFPA National Fire Protection Association Life Safety Code IRC International Residence Code March 2011 Certain cities, counties and states have written their own code requirements which may supersede or supplement model building codes, check with these authorities for approvals. Bio FireShield Products are UL Classified and conform to the codes and test requirements shown below. UL Fire Tests of Through-Penetration Firestops UL Tests for Fire Resistance of Building Joint Systems ASTM E Standard Test Method for Fire Resistive Joint Systems ASTM E Methods for Fire Tests of Through-Penetration Fire Stops NFPA National Fire Protection Association Life Safety Code ASTM E 84 (UL 723).. Test Method for Surface Burning Characteristics of Building Materials ASTM E 119 (UL 263).. Method for Fire Tests of Building Construction and Materials ULC CAN4-S115M.... Standard Method of Fire Tests of Firestop Systems B.S. 476/ pr EN European/ British Standards AS Part 4: Fire Resistance Tests of Elements of Building Construction AS Part 1: Service Penetration and Control Joint For Questions or Additional Information call Technical Service Fax Page 1

4 Page 2

5 Page 3

6 To Whom It May Concern: RectorSeal s Warranty statement for firestop is contingent upon actual storage conditions and proper installation. If RectorSeal firestop products are correctly installed in accordance with our stated Manufacturers instructions and according to the UL tested systems, our products comply with UL 1479 "Fire Tests for Through-Penetration Firestop" and UL 2079 Test for Fire Resistance of Building Joint System standard requirements for Environmental Exposure Tests. This test relates to the performance of firestop products as originally installed, and compares to the performance testing after exposure to extreme temperatures and high humidity for an extended period of time. If properly stored, our products have a minimum shelf life of two years, subject to inspection with the exception of our silicone product which has a one year shelf life. The RectorSeal Corporation, manufacturer of Metacaulk, Bio Firesheild and Flamesafe firestop products, has always been concerned about the long-term performance of our products. We implemented a testing program prior to the UL s requirement for Fire Tests for Through- Penetration Firestop and UL 2079 Test for Fire Resistance of Building Joint System. We burned materials in our UL sanctioned fire test facility to measure the performance of RectorSeal products after extended periods of time as in accordance with current standards. Some of the tested materials exceed 15 years in age. Assuming that the substrate area surrounding the actual penetration or construction joint has not been damaged, we warrant that Metacaulk, Bio Firesheild and Flamesafe products will perform satisfactorily for the sustainable life of the building. Sincerely, RECTORSEAL Larry Kaiser Larry Kaiser Vice President of Sales Page 4

7 March 3, 2016 To Whom It May Concern: RectorSeal s Warranty Statement for our Smoke and Acoustical sealant is contingent upon actual storage conditions and proper installation. If properly stored, our RectorSeal Smoke and Acoustic Sealant has a minimum shelf life of two years, subject to inspection. Assuming that the substrate area surrounding the actual penetration/joint has not been damaged, we warrant that the RectorSeal Smoke and Acoustic Sealant product, when fully cured will perform satisfactorily for the sustainable life of the building. If there are any additional questions, do not hesitate to call our office at Respectfully, RECTORSEAL Terry Gossett Terry Gossett Technical Services Page 5

8 2601 Spenwick Dr Houston, TX ph: fax: May 26, 2011 RE: RectorSeal Smoke and Acoustic Sealant LEED Product Information TO: Whom It May Concern This letter will detail the contribution of RectorSeal Smoke and Acoustic Sealant materials to the LEED Green Building Rating System in accordance with LEED-NC, CS, CI and School Rating Systems. MR Credit 2.1: Construction Waste Management, Divert 50% form Disposal MR Credit 2.2: Construction Waste Management, Divert 75% from Disposal In areas where facilities exist, the following RectorSeal Smoke and Acoustic Sealant materials are recyclable and can contribute to earning Materials and Resources Credit 2.1 or Credit 2.2. Carton Cardboard 2 lbs / carton 20.2 oz foil pack Mylar 5 g. / pack 5 gallon pail HDPE 934 g. / pail Wooden pallet wood 45 lbs. / pallet MR Credit 5.1: Regional Materials, 10% Extracted, Processed & Manufactured Regionally MR Credit 5.2: Regional Materials, 20% Extracted, Processed & Manufactured Regionally RectorSeal Smoke and Acoustic Sealant materials are manufactured in one location Houston, Texas. If these locations fall within a 500-mile radius of the project site and the location the raw materials used to make the finished product are extracted, recovered or harvested within a 500-mile radius of the project, then these materials or a portion of the materials can contribute to earning Materials and Resources Credit 5.1 and Credit 5.2. The following are the locations of the RectorSeal Smoke and Acoustic Sealant materials manufacturing plants: RectorSeal Product Smoke and Acoustic Sealant Location Houston, Texas Page 6

9 Please contact your local RectorSeal Representative to request a project specific letter pertaining to Credit 5.1 and Credit 5.2. The letter will provide the location where the raw materials are extracted, recovered or harvested in relation to the location of the project. EQ Credit 4.1: Low Emitting Materials, Adhesives & Sealants EQ Credit 4.2: Low Emitting Materials, Paints & Coatings The volatile organic content (VOC) of RectorSeal Smoke and Acoustic Sealant materials is listed below for those products that are lower than the minimum LEED requirements for low-emitting materials. These materials can help contribute to earning Indoor Environmental Quality EQ Credit 4.1 and 4.2. RectorSeal Product EQ Credit VOC Content (g/l) RectorSeal Smoke and Acoustic Sealant 4.1 <10 (Caulk Grade) RectorSeal Smoke and Acoustic Sealant 4.2 <10 (Spray Grade) Please feel free to contact me with any additional questions or information. Sincerely, Terry Gossett Technical Service Page 7

10 PRODUCT DATA SHEET RectorSeal Track-Safe January 2015 Classified Construction Joint Fire Stop System Numbers BW-S-0030, BW-S-0031, HW-D HW-D-0709, HW-D-0710, HW-D-0711, HW-D-0712, HW-D-0713, HW-D-0714, HW-D-0716, HW-D-0717, HW-D-0718, HW-D-0719, HW-D-0720, HW-D-0721, HW-D-0722, HW-D-0723, HW-D-0724, WW-D-0148, WW-D-0149, WW-D-0162 & WW-D Product Description RectorSeal Track-Safe is a galvanized steel L shaped angle with an intumescent strip that permanently attaches to one side of a deep leg header track. RectorSeal Track-Safe Features Is designed for one side installation of fire resistive head of wall joints up to 2 hours F rating, RectorSeal Track- Safe angle provides complete dynamic movement with 100% unencumbered joint extension and compression capabilities as well as drift movement with zero fatigue of joint and firestop material on deep leg track in steel stud wall assemblies. Track-Safe is installed from only one side of the wall and is simply friction fit to the side of the header track. 2. Material Properties Asbestos Fillers Solvents Hazardous Ingredients None None None Size (Approx.) 5/8" x 1.5" x 10' 5/8" s 2.5" x 10' Activation of Intumescence: Expansion Begins 375 F (190 C) Expansion Greatest 575 F (302 C) to 1100 F (593 C) Color Freeze-Thaw Red Excellent 3. Applications RectorSeal Track-Safe is installed on dynamic and static head of wall & bottom of wall joints where deep leg track and steel studs are used. 4. Installation Data RectorSeal Track-Safe is simple to install. Install on only one side of wall assembly, friction fit by way of lightly tapping shorter leg of Track-Safe angle into joint between ceiling assembly and deep leg track so longer leg of Track-Safe angle extends vertically down outside edge of track. Joints can be butted or overlapped at seams. (A) (A) Applications with concrete deck 1. Install head of wall deep leg header track to concrete deck as recommended by track manufacturer. 2. On one side of track assembly, lightly tap angle into place so that the 5/8 leg of Track-Safe angle is friction fit between steel track and concrete deck so that intumescent tape is in contact with outside edge of deep leg track. a. Studs can be installed prior to or after Track-Safe installation. b. Track-Safe must be installed prior to gypsum board installation. 3. Joints between Track-Safe segments can be abutted tightly or overlapped. 4. Inside and outside corners must be overlapped by minimum of The 5/8 leg may be cut perpendicular to allow Track-Safe to follow radius walls. 6. No mechanical fastening of Track-Safe is required. 7. Install wall sheathing over Track-Safe to complete wall assembly. (B) Applications with fluted deck 1. Install head of wall deep leg header track to fluted deck as recommended by track manufacturer. 2. On one side of header track assembly, lightly tap angle into place so that the 5/8 leg of Track- Safe angle is friction fit between steel track and fluted deck so that intumescent tape is in contact with outside edge of deep leg track. (B) Page 8

11 RECTORSEAL TRACK-SAFE a. Studs can be installed prior to or after Track-Safe installation. b. Track-Safe must be installed prior to gypsum board installation. 3. Insert precut mineral wool plugs (minimum 4 pcf) into flute area above track. 4. On one side of track assembly only, coat mineral wool plug with approved RectorSeal firestop sealant, overlapping into track and deck as required by the UL listed system. a. Firestop sealant can be installed on either side of wall (same or opposite as Track- Safe angle). b. Firestop sealant may be applied before gypsum installation. 5. Joints between Track-Safe segments can be abutted tightly or overlapped. 6. Inside and outside corners must be overlapped by minimum The 5/8 leg may be cut perpendicular to allow Track-Safe to follow radius walls. 8. No mechanical fastening of Track-Safe is required. 9. Install wall sheathing over Track-Safe to complete wall assembly. Consult UL Directory for complete instructions and system listings. 5. Testing Data RectorSeal Track-Safe is classified by Underwriters Laboratories as a Fill, Void or Cavity Material. For specific test criteria, see UL Fire Resistance Directory or call RectorSeal. RectorSeal Track-Safe was tested in accordance with UL 2079, ASTM E 1966 and ASTM E 1399 test standards. ASTM E 90. STC rating 57. L rating< 1 CFM. F rating up to 2 hours. 6. Storage & Handling RectorSeal Track-Safe should be stored in a cool, dry place. Keep products stored under protective cover, in their original containers. A stock rotation program is recommended. 7. Availability RectorSeal Track-Safe is available in 5/8 by 1-1/2 by 10 long pieces in case quantities of 20 pieces and 5/8 by 2-1/2 by 10 long pieces in case quantities of 10 pieces 8. Limitations To be used only in the tested configurations or as recommended by RectorSeal. Is not to be used with slotted track or in joints that require movement greater than 1-1/2. 9. Cautions FOR CHEMICAL EMERGENCY, SPILL, LEAK, FIRE, EXPOSURE OR ACCIDENT, CALL CHEMTREC-DAY OR NIGHT PRECAUTIONS: Do not take internally. May be harmful if swallowed. May cause eye and skin irritation if prolonged or repeated contact occurs. Wash after handling. FIRST AID: For any overexposure, get immediate medical attention after first aid is given. Eyes- Flush 15 minutes with clean water. Skin-Wash with soap and water. Ingestion-Only if conscious, give large amounts of water and INDUCE VOMITING. FIRE AND SPILLS: Use water fog, CO 2, foam, or dry chemicals. Wipe up spills to prevent footing hazard. Clean up with scrapers and water. STORAGE AND HANDLING: Store away from heat sources. KEEP OUT OF REACH OF CHILDREN. For additional information, refer to Material Safety Data Sheet. For additional technical service, call: or fax: or RECTORSEAL 2601 Spenwick Drive, HOUSTON, TEXAS LIMITED WARRANTY RectorSeal makes the Limited Express Warranty that when the instructions for storage and handling of our products are followed we warrant our products to be free from defects. THIS LIMITED EXPRESS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PAR- TICULAR PURPOSE, AND OF ANY OTHER OBLIGATION ON THE PART OF RECTORSEAL. The sole remedy for breach of the Limited Express Warranty shall be the refund of the purchase price. All other liability is negated and disclaimed, and RectorSeal shall not be liable for incidental or consequential damages. Suggestions and recommendations covering the use of our products are based on our past experience and laboratory findings. However, as we have no control as to the methods and conditions of application, we only assume responsibility for the uniformity of our products within manufacturing tolerances. A-15 Page 9

12 System No. HW-D-0710 October 30, 2013 ANSI/UL2079 CAN/ULC S115 Assembly Rating 2 Hr Nominal Joint Width - 3/8 in. Class II and III Movement Capabilities 100% Compression or Extension L Rating At Ambient Less Than 1 CFM/Lin ft L Rating At 400 F Less Than 1 CFM/Lin ft F Rating 2 Hr FT Rating 2 Hr FH Rating 2 Hr FTH Rating 2 Hr Nominal Joint Width - 3/8 in. Class II and III Movement Capabilities 100% Compression or Extension L Rating At Ambient Less Than 1 CFM/Lin ft L Rating At 400 F Less Than 1 CFM/Lin ft 1. Floor or Roof Assembly Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. 2. Shaft Wall Assembly The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Floor and Ceiling Runners "J"-shaped runner, min 4 in. (102 mm) wide with unequal legs of min 1 in. (25 mm) and min 2 in. (51 mm), fabricated from min 24 MSG galv steel. Ceiling runner installed with short leg toward finished side of wall. Floor or ceiling runner to be attached to concrete with steel masonry fasteners spaced a max of 24 in. (610 mm) O.C. As an alternate to the "J"-shaped runner, a min 4 in. (102 mm) wide by 1 or 1-1/4 in. (25 or 32 mm) deep channel formed from min 24 MSG galv steel may be used for the floor runner. B. Studs "C-T", "I", or "C-H" shaped steel studs to be min 4 in. (102 mm) wide and formed of min 25 ga galv steel. Studs cut ¾ to 1 in. (19 to 25 mm) less in length than assembly height with bottom nesting in and secured to floor runner. Studs spaced max 24 in. (610 mm) OC. C. Gypsum Board* 1 in. (25 mm) thick by max 24 in. (610 mm) wide gypsum board liner panels. Panels cut max 1 in. (25 mm) less in length than floor to ceiling height. Vertical edges inserted into "T" shaped section of "C-T" studs, into holding tabs of "I" studs or into "H"-shaped section of "C-H" studs. Page 10

13 D. Gypsum Board* Gypsum board 1/2 or 5/8 in. (13 or 16 mm) thick, applied on finished side of wall as specified in the individual Wall and Partition Design. The boards cut a max 3/8 in. (9.5 mm) less in length than the floor to ceiling height. The screws attaching the gypsum board layer(s) to the "C-T", "I", or "C-H" studs shall be located 3 to 3-1/2 in. (76 to 89 mm) below the floor. 3. Joint System Max separation between bottom of floor and top of gypsum board on finished side of wall (at time of installation) is 3/8 in. (9.5 mm). The joint system is designed to accommodate a max 100 percent compression and extension from its installed width. The joint system shall consist of the following: A. Forming Material* Min 3 in. thickness of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation cut to width of stud, compressed min 25 percent in width and friction fit into ceiling runner between leg of track and gypsum liner board. See Forming Material (XHKU) category in the Fire Resistance Directory for names of manufacturers. B. Fill, Void or Cavity Material* Min 25 ga composite steel angle with one 5/8 in. (16 mm) leg and one 1-1/2 in (38 mm) leg with an intumescent strip affixed along the inside 1-1/2 in (38 mm) leg. The 5/8 in. leg of steel angle is friction fit between the top web of the ceiling runner and the floor on either side of wall assembly. RECTORSEAL Track Safe *Bearing the UL Classification Mark Page 11

14 System No. HW-D-0711 November 07, 2013 ANSI/UL2079 CAN/ULC S115 Assembly Ratings - 1 and 2 Hr (See Item 2) F Ratings - 1 and 2 Hr (See Item 2) Nominal Joint Width - 1/2 In. and 1 In. FT Ratings -1 and 2 Hr (See Item 2) Class II or III Movement Capabilities - 100% Compression or Extension for Nom 1/2 In. Joint; 100% Compression or 0% Extension for Nom 1 In. Joint FH Ratings - 1 and 2 Hr (See Item 2) L Rating At Ambient Less Than 1 CFM/Lin ft FTH Ratings - 1 and 2 Hr (See Item 2) L Rating At 400 F Less Than 1 CFM/Lin ft Nominal Joint Width - 1/2 In. and 1 In. Class II or III Movement Capabilities - 100% Compression or Extension for Nom 1/2 In. Joint; 100% Compression or 0% Extension for Nom 1 In. Joint L Rating At Ambient Less Than 1 CFM/Lin ft L Rating At 400 F Less Than 1 CFM/Lin ft 1. Floor or Roof Assembly Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. 2. Wall Assembly The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Ceiling Runners Channel shaped runner with width to accommodate studs, legs of min 2 in. (51 mm), and fabricated from min 25 MSG galv steel. Floor runners of wall assembly shall consist of min No. 25 ga galv steel channels sized to accommodate the steel studs. Floor runner to be provided with min 1-1/4 in. (32mm) flanges. Floor or ceiling runner to be attached to concrete with steel masonry fasteners spaced a max of 24 in. (610 mm) O.C. B. Studs Steel studs to be min 3-5/8 in. (92 mm) wide. Studs cut 3/4 to 1 in. (19 to 25 mm) less in length than assembly height with bottom nesting in and secured to floor runner. Steel studs nested in ceiling runner without attachment. C. Gypsum Board* Gypsum board 1/2 or 5/8 in. (13 or 16 mm) thick, applied on both sides of wall as specified in the individual Wall and Partition Design except that a max 1 in. (25 mm) gap shall be maintained between the top of the gypsum board and the bottom of the floor assembly. The screws attaching the gypsum board to the studs along the top of the wall shall be located 3 to 3-1/2 in. (76 to 89 mm) down from floor at time of installation. No gypsum board Page 12

15 attachment screws shall be driven into the ceiling runner. The hourly F, FT, FH and FTH Ratings of the joint systems are equal to the hourly rating of the wall. 3. Joint System Max separation between bottom of floor and top of gypsum board (at time of installation) is 1 in. (25 mm). The joint system is designed to accommodate a max 100 percent compression or extension from its installed width for a nom 1/2 in. joint. The joint system is designed to accommodate a max 100 percent compression or 0% extension from its installed width for a nom 1 in. joint. The joint system shall consist of the following: A. Fill, Void or Cavity Material* Min 25 ga composite steel angle with one 5/8 in. (16 mm) leg and one 1-1/2 in (38 mm) leg with an intumescent strip affixed along the inside 1-1/2 in (38 mm) leg. The 5/8 in. leg of steel angle is friction fit between the top web of the ceiling runner and the floor. Steel angle is required on one side of wall only (either side). RECTORSEAL Track Safe * Indicates such products shall bear the UL or cul Certification Mark for jurisdictions employing the UL or cul Certification (such as Canada), respectively. Page 13

16 System No. HW-D-0723 October 28, 2013 ANSI/UL2079 CAN/ULC S115 Assembly Rating 1 and 2 Hr (See Item 2) F Ratings 1 and 2 Hr (See Item 2) Nominal Joint Width - 1/2 in. or 1 in. FT Ratings 1 and 2 Hr (See Item 2) Class II or III Movement Capabilities 100% Compression or Extension for 1/2 in. Joint; 100% Compression or 0% Extension for 1 in. Joint FH Ratings 1 and 2 Hr (See Item 2) L Rating at Ambient Less than 1 CFM/Lin Ft FTH Ratings 1 and 2 Hr (See Item 2) L Rating at 400 F Less than 1 CFM/Lin Ft Nominal Joint Width - 1/2 in. or 1 in. Class II or III Movement Capabilities 100% Compression or Extension for 1/2 in. Joint; 100% Compression or 0% Extension for 1 in. Joint L Rating at Ambient Less than 1 CFM/Lin Ft L Rating at 400 F Less than 1 CFM/Lin Ft 1. Floor Assembly Min 4-1/2 in. (114 mm) thick steel reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. Floor may also be constructed of any min 6 in. (152 mm) thick UL Classified hollow-core Precast Concrete Units*. See Precast Concrete Units (CFTV) category in the Fire Resistance Directory for names Page 14

17 manufacturers. The hourly fire rating of the floor assembly shall be equal or greater than the hourly fire rating of the wall assembly 2. Wall Assembly The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Ceiling Runners Channel shaped ceiling runner with width to accommodate studs, legs of min 2 in. (51 mm), and fabricated from min 24 MSG galv steel. Floor runners of wall assembly shall consist of min No. 25 ga galv steel channels sized to accommodate the steel studs. Floor runner to be provided with min 1-1/4 in. (32 mm) flanges. Runners to be attached to concrete floor with steel masonry fasteners spaced a max of 24 in. (610 mm) O.C. B. Studs Steel studs to be min 3-1/2 in. (89 mm) wide. Studs cut nom 1 in. (25 mm) less in length than assembly height with bottom nesting in and secured to floor runner. Studs to nest in ceiling runner without attachment. Studs spaced max 24 in. (610 mm) OC. C. Gypsum Board* Gypsum board sheets installed to a min total 5/8 in. (16 mm) or 1-1/4 in. (32 mm) thickness on each side of wall for 1 and 2 hr fire rated assemblies, respectively. Wall to be constructed as specified in the individual Wall and Partition Design in the UL Fire Resistance Directory except that a max 1 in. (25 mm) gap shall be maintained between the top of the gypsum board and the bottom of the floor assembly. Gypsum board on shaft side to overlap legs of ceiling runner min ½ in. (13 mm). The screws attaching the gypsum board to the studs along the top of the wall shall be located 1 to 1-1/2 in. (25 to 38 mm) below the bottom of the ceiling runner legs. No gypsum board attachment screws shall be driven into the ceiling runner. D. Gypsum Board* Gypsum board sheets installed to a min total 5/8 in. (16 mm) or 1-1/4 in. (32 mm) thickness on each side of wall for 1 and 2 hr fire rated assemblies, respectively. Wall to be constructed as specified in the individual Wall and Partition Design in the UL Fire Resistance Directory except shaft side gypsum board to extend a max of 1/2 in. (13 mm) below the upper floor line overlapping the ceiling runner a min of 1/2 in. (13 mm). Gypsum board attached to the ceiling runner of the lower level. A max 1 in. (25 mm) gap shall be maintained between the edges of gypsum board of wall below to allow for movement capability of the joint. The hourly fire rating of the joint system is equal to the hourly fire rating of the wall. 3. Joint System Max separation between bottom of floor and top edge of gypsum board (non-shaft side) and between edges of gypsum board (shaft side) at time of installation is 1 in. (25 mm). The joint system is designed to accommodate a max 100 percent compression or extension from its installed width when joint width is nom 1/2 in. The joint system is designed to accommodate a max 100 percent compression or 0% extension from its installed width when joint width is nom 1 in. The joint system shall consist of the following: A. Fill, Void or Cavity Material* Min 25 ga composite steel angle with one 5/8 in. (16 mm) leg and one 1-1/2 in (38 mm) leg with an intumescent strip affixed along the inside 1-1/2 in (38 mm) leg. The 5/8 in. leg of steel angle is friction fit between the top web of the ceiling runner and the concrete floor. Steel angle is required on non-shaft side of wall only. RECTORSEAL Track Safe *Bearing the UL Classification Mark Page 15

18 System No. HW-D-0724 October 24, 2013 ANSI/UL2079 CAN/ULC S115 Assembly Rating 1 and 2 Hr (See Item 2) F Rating 1 and 2 Hr (See Item 2) Nominal Joint Width - 3/8 in. FT Rating 1 and 2 Hr (See Item 2) Class II and III Movement Capabilities 100% Compression or Extension FH Rating 1 and 2 Hr (See Item 2) L Rating at Ambient Less than 1 CFM/Lin Ft FTH Rating 1 and 2 Hr (See Item 2) L Rating at 400 F Less than 1 CFM/Lin Ft Nominal Joint Width - 3/8 in. Class II and III Movement Capabilities 100% Compression or Extension L Rating at Ambient Less than 1 CFM/Lin Ft L Rating at 400 F Less than 1 CFM/Lin Ft 1. Floor Assembly Min 4-1/2 in. (114 mm) thick steel reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. Floor may also be constructed of any min 6 in. (152 mm) thick UL Classified hollow-core Precast Concrete Units*. See Precast Concrete Units (CFTV) category in the Fire Resistance Directory for names manufacturers. Page 16

19 The hourly fire rating of the floor assembly shall be equal or greater than the hourly fire rating of the wall assembly. 2. Shaft Wall Assembly The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Floor and Ceiling Runners "J"-shaped runner, min 4 in. (102 mm) wide with unequal legs of min 1 in. (25 mm) and min 2 in. (51 mm), fabricated from min 24 MSG galv steel. Ceiling runner installed with short leg toward finished side of wall. Floor or ceiling runner to be attached to concrete floor with steel fasteners spaced a max of 24 in. (610 mm) OC. B. Studs "C-T", "I", or "C-H" shaped steel studs to be min 4 in. (102 mm) wide and formed of min 25 ga galv steel. Studs cut 5/8 to 3/4 in. (16 to 19 mm) less in length than assembly height with bottom nesting in floor runner. Studs spaced max 24 in. (610 mm) OC. C. Gypsum Board* 1 in. (25 mm) thick by max 24 in. (610 mm) wide gypsum board liner panels. Panels cut max 1 in. (25 mm) less in length than floor to ceiling height. Vertical edges inserted into "T" shaped section of "C-T" studs, into holding tabs of "I" studs or into "H"-shaped section of "C-H" studs. D. Gypsum Board* Gypsum board sheets installed to a min total 5/8 in. (16 mm) or 1-1/4 in. (32 mm) thickness on finished side of wall for 1 and 2 hr fire rated assemblies, respectively. Wall to be constructed as specified in the individual Wall and Partition Design in the UL Fire Resistance Directory except gypsum board on finished side of upper wall to extend a max of 1/2 in. (13 mm) below the floor line overlapping the ceiling runner of lower wall by a min of 1/2 in. (13 mm) and attached to the ceiling runner. A max 3/8 in. (25 mm) gap shall be maintained between the edges of gypsum board of wall below to allow for movement capability of the joint. The hourly fire rating and the F, FT. FH and FTH ratings of the joint system is equal to the hourly fire rating of the wall. 3. Joint System Max separation between edges of gypsum board on finished side of walls at time of installation is 3/8 in. (9.5 mm). The joint system is designed to accommodate a max 100 percent compression or extension from its installed width. The joint system shall consist of the following: A. Forming Material* Min 3 in. (76 mm) thickness of min 4 pcf (64 kg/m 3 ) mineral wool batt insulation cut to width of stud, compressed min 25 percent in width and friction fit into ceiling runner between leg of track and gypsum liner board. See Forming Material (XHKU) category in the Fire Resistance Directory for names of manufacturers. B. Fill, Void or Cavity Material* Min 25 ga composite steel angle with one 5/8 in. (16 mm) leg and one 1-1/2 in (38 mm) leg with an intumescent strip affixed along the inside 1-1/2 in (38 mm) leg. The 5/8 in. leg of steel angle is friction fit between the top web of the ceiling runner and the concrete floor on one side of wall only. RECTORSEAL Track Safe *Bearing the UL Classification Mark Page 17

20 System No. HW-D-0717 October 24, 2013 ANSI/UL2079 CAN/ULC S115 Assembly Ratings 1 and 2 Hr (See Item 2) F Ratings 1 and 2 Hr (See Item 2) Nominal Joint Width - 1/2 in. FT Ratings 1 and 2 Hr (See Item 2) Class II or III Movement Capabilities 100% Compression or Extension for 3/8 In. Joint; 100% Compression or 0% Extension for 3/4 In. Joint FH Ratings 1 and 2 Hr (See Item 2) L Rating at Ambient Less than 1 CFM/Lin Ft FTH Ratings 1 and 2 Hr (See Item 2) L Rating at 400 F Less than 1 CFM/Lin Ft Nominal Joint Width - 1/2 in. Class II or III Movement Capabilities 100% Compression or Extension L Rating at Ambient Less than 1 CFM/Lin Ft L Rating at 400 F Less than 1 CFM/Lin Ft 1. Floor or Roof Assembly Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight ( pcf or kg/m 3 ) structural concrete. 2. Chase Wall Assembly The 1 or 2 hr fire rated gypsum board/stud chase (double stud) wall assembly shall be constructed of the materials and in the manner described in the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Ceiling Runners Channel shaped ceiling runner with width to accommodate studs, legs of min 2 in. (51 mm), and fabricated from min 24 MSG galv steel. Floor runners of wall assembly shall consist of min No. 25 ga galv steel channels sized to accommodate the steel studs. Floor runner to be provided with min 1-1/4 in. (32mm) flanges. Ceiling runner to be attached to concrete floor with steel masonry fasteners spaced a max of 24 in. (610 mm) O.C. B. Studs Steel studs to be min 3-1/2 in. (89 mm) wide and formed of min 25 ga galv steel. Studs cut 3/4 to 1 in. (19 to 25 mm) less in length than assembly height with bottom nesting in and secured to floor runner. Steel studs nested in ceiling runner without attachment. Studs spaced max 24 in. (610 mm) OC. C. Gypsum Board* Gypsum board 1/2 or 5/8 in. (13 or 16 mm) thick, applied on both sides of wall as specified in the individual Wall and Partition Design except that a max 1/2 in. (13 mm) gap shall be maintained between the top of the gypsum board and the bottom of the floor assembly. The screws attaching the gypsum board to the studs along the top of the wall shall Page 18

21 be located 3 to 3-1/2 in. (76 to 89 mm) down from floor at time of installation. No gypsum board attachment screws shall be driven into the ceiling runner. The hourly assembly rating and F, FT, FH and FTH ratings of the joint system is equal to the hourly fire rating of the wall. 3. Joint System Max separation between bottom of floor and top of gypsum board (at time of installation) is 1/2 in. (13 mm). The joint system is designed to accommodate a max 100 percent compression or extension from its installed width. The joint system shall consist of the following: A. Fill, Void or Cavity Material* Min 25 ga composite steel angle with one 5/8 in. (16 mm) leg and one 1-1/2 in (38 mm) leg with an intumescent strip affixed along the inside 1-1/2 in (38 mm) leg. The 5/8 in. leg of steel angle is friction fit between the top web of one ceiling runner and the concrete floor. Steel angle is required on one side of wall only (either side). RECTORSEAL Track Safe *Bearing the UL Classification Mark Page 19

PRODUCT DATA SHEET Metacaulk BOX GUARD Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory

PRODUCT DATA SHEET Metacaulk BOX GUARD Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory PRODUCT DATA SHEET Metacaulk BOX GUARD Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory January 2011 1. Product Description Metacaulk BOX GUARD is a one component

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Waterproof Contractor Submittal (Joint Strip) Manufacturer's Representative: Rectorseal

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): WP Contractors - Concrete Control Joints - BF 750 Manufacturer's Representative:

More information

System No. HW-D-0548

System No. HW-D-0548 System No. Ì73hwdÇ%P+11bÎ ANSI/UL2079 Assembly atings - 1 and 2 Hr (See Item 2) Maximum Joint Width - 3/4, 1 or 1-1/2 In. (See Item 3) Class II Movement Capabilities - 50 or 100 %Compression or Extension

More information

XHBN.HW-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. HW-D-0631

XHBN.HW-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. HW-D-0631 Page Bottom XHBN.HW-D-0631 Joint Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering

More information

UL Design System HW-D-1012 continued

UL Design System HW-D-1012 continued UL System No. HW-D-1012 Assembly Ratings 1, 2 and 3 Hr (See Item 2) Nominal Joint Width 3 in. Class II and III Movement Capabilities 100% Compression or Extension Page 1 of 5 1. Floor Assembly The fire-rated

More information

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000? TRACK 1000 FIRE MANAGEMENT PRODUCTS TECHNICAL PRODUCT GUIDE www.cemcosteel.com WHY I SHOULD SPECIFY AND USE FAS TRACK 1000? SOUND BENEFITS: Whether the protection you need is Fire, Air (Smoke), or Sound

More information

System No. HW-D-0119

System No. HW-D-0119 System No. HW-D-0119 August 03, 2007 Assembly Rating 1, 2 and 3 Hr (See Item 2) Nominal Joint Width 1 In. Class II and III Movement Capabilities 100% Compression or Extension 1. Floor Assembly The fire-rated

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Drywall Contractor Submittal - Sealant & Blazefoam Manufacturer's Representative:

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Waterproof Contractor Submittal (Joint Strip) Manufacturer's Representative: Rectorseal

More information

FIRE MANAGEMENT PRODUCTS FAS Track 1000 DDA (Deflection Drift Angle ) HOTROD Type-X

FIRE MANAGEMENT PRODUCTS FAS Track 1000 DDA (Deflection Drift Angle ) HOTROD Type-X FIRE MANAGEMENT PRODUCTS FAS Track 1000 DDA (Deflection Drift Angle ) HOTROD Type-X TM PRODUCT CATALOG 100% American-Owned and Operated marinoware.com ASTM/STANDARDS DECLARATION LEED V4 FOR BUILDING &

More information

The System U.S. Patent No. 5,913,788

The System U.S. Patent No. 5,913,788 The System U.S. Patent No. 5,913,788 UL System No. HW-D-0027 2 Hour Rated Assembly (Metal Decking) UL System No. HW-D-0028 1 Hour Rated Assembly (Metal Decking) UL System No. HW-D-0208 1 Hour Rated Assembly

More information

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM U.L. FIRE RATED Head-of-Wall Joint Systems 1-800-275-2279 STEELER INC. SLOTTED STUD 1-800-275-2279 The STEELER SLOTTED STUD is an innovative

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIESTOP SUBMITTAL PACKAGE Head of Wall Firestop Submittal POJECT: DATE: September 28, 2011 SUBMITTED BY: Brent Johnson STI Firestop 415-515-3767 bjohnson@stifirestop.com 200 Evans Way Somerville, NJ 08876

More information

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 International Fireproof Technology Inc. 17528 Von Karman Avenue Irvine, CA 92614 This report is for the exclusive

More information

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.V481 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008 XHBN.FF-D-3008 - Page 1 of 2 XHBN.FF-D-3008 Page Bottom See General Information for System No. FF-D-3008 March 20, 2006 Assembly Rating 2 Hr Nominal Joint Widths 14, 16, 18 and 20 In. (See Item 2A) Class

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

Duct Wrap Flexible Wraps

Duct Wrap Flexible Wraps Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone

More information

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet 3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet 1. Product Description 4 in. x 8 in. (101.6 mm x 203.3 mm), 7 in. x 7 in. (177.8 mm x 177.8 mm) and 9.5 in. x 9.5 in. (241.2 mm x 241.3 mm) pad

More information

Fire Protection Products

Fire Protection Products Fire Protection Products Product Data Sheet January / 2017 Product Description Product Features Applications Specifications is a sprayable, moisture-curing hybrid siliconized polymer that forms a tough,

More information

Fire Barrier. Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes

Fire Barrier. Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes 3 Fire Barrier Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes This information brochure highlights requirements for UL listed, fire-rated electrical boxes located in some UL

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Commercial Plumbing - Steel Pipes Manufacturer's Representative: Rectorseal -

More information

BlazeFrame product catalog STRONGER. clarkdietrich.com/blazeframe

BlazeFrame product catalog STRONGER. clarkdietrich.com/blazeframe BlazeFrame product catalog STRONGER T H A N S T E E L. SM I N T E G R AT E D F I R E S T O P S Y S T E M S /BlazeFrame 2 BlazeFrame Design Advantages What is BlazeFrame? BlazeFrame products are innovative

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Commercial Plumbing Contractors (PVC & PEX Thru Gyp Board) Manufacturer's Representative:

More information

Fire Protection Products

Fire Protection Products Fire Protection Products Product Data Sheet July 2017 Product Description Product Features Applications Specifications is a sprayable, moisture-curing, hybrid siliconized polymer that forms a tough, elastomeric

More information

Joint Systems. System No. FF-D-0044

Joint Systems. System No. FF-D-0044 XHBN.FF-D-0044 System No. FF-D-0044 November 05, 2003 Assembly Rating 2 Hr Nom Joint Width 1 in. Class II and III Movement Capabilities 50% Compression or Extension 1. Floor or Wall Assembly Reinforced

More information

3M Fire Protection Products 3M Interam Endothermic Mat For Commercial Buildings

3M Fire Protection Products 3M Interam Endothermic Mat For Commercial Buildings 3M Fire Protection Products For Commercial Buildings Tested in accordance with AS1530.4-005 Get wrapped up in opens up new opportunities in building design, allowing architects to fulfill the UL mark of

More information

FIRESTOP TECHNICAL PACK TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL (7325)

FIRESTOP TECHNICAL PACK TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL (7325) FIRESTOP TECHNICAL PACK FIRESEAL 814 Acrylic Intumescent Caulk Polymer Adhesives Sealant Systems, Inc. 501 Garrett Morris Parkway Mineral Wells, TX 76067 TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

St. Monica Food Pantry

St. Monica Food Pantry St. Monica Food Pantry 07 8400-1 SECTION 07 8400 - FIRESTOPPING PART 1 - GENERAL 1.1 SUMMARY: A. Related work: 1. Concrete. 2. Mortar and grout. 3. Brick masonry. 4. Concrete unit masonry. 5. Structural

More information

SECTION NON--STRUCTURAL METAL FRAMING

SECTION NON--STRUCTURAL METAL FRAMING The Collective Voice of America s Steel Framing Industry The Steel Framing Industry Association (SFIA) is dedicated to expanding the market for cold-formed steel in construction through programs and initiatives

More information

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 7 Page Bottom BXUV.U415 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U415 July 30,

More information

PARKING PLAZA MEXICO COVERED GAS PUMP ISLAND PARKING BUS PARKING AREA. The Evans Group COVERD AREA TACO STAND COVERD AREA AREA FREEZER EXIT EXIT

PARKING PLAZA MEXICO COVERED GAS PUMP ISLAND PARKING BUS PARKING AREA. The Evans Group COVERD AREA TACO STAND COVERD AREA AREA FREEZER EXIT EXIT OFFICE FUEL ISLAND ATTENDANTS OFFICE GAS PUMP ISLAND BUS SIGNAGE AND 6'-0" WALL TACO STAND COVERED RESTROOMS RESTROOMS MARKET TACO STAND PLAZA MEXICO COVERED FREEZER GAS PUMP ISLAND BUS FUEL ISLAND ATTENDANTS

More information

F I R E M A N A G E M E N T P R O D U C T S DEFLECTION

F I R E M A N A G E M E N T P R O D U C T S DEFLECTION F I R E M A N A G E M E N T P R O D U C T S DEFLECTION FIRE FIRE AIR AIR SOUND SOUND w w w. c e m c o s t e e l. c o m TA BLE TABLE OF OF CONTENTS FAS Track About FAS Track......................................................................

More information

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 International Beams Inc. 2010 Boul. St-Elzear Quest Laval, QC H7L 3N4 CANADA This report is for the exclusive use of Intertek

More information

Cavity ShAftwall System

Cavity ShAftwall System 09 9 00/NGC Cavity shaftwall systems are non-load-bearing, -hour to -hour, fire-rated partitions constructed from one side used to enclose elevator shafts, stairs and mechanical shafts where the design

More information

Fire Barrier Duct Wrap 615+

Fire Barrier Duct Wrap 615+ Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire

More information

System No. C-AJ-8133

System No. C-AJ-8133 System No. C-AJ-8133 March 09, 2011 F Ratings - 1, 1-1/2, 2 and 3 Hr (See Item 2) T Ratings - 0, 1/2, 3/4, 1, 1-1/2, 2 and 3 Hr (See Item 2) 1. Floor or Wall Assembly Min 4-1/2 in. (114 mm) thick reinforced

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIRESTOP SUBMITTAL PACKAGE HVAC Materials FS-ONE Intumesent Caulk CP 606 Acrylic Includes: Technical and Installation Data UL Certificate of Compliance LEED information MSDS UL Details Concrete Assemblies

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower I-Stud and CertainTeed Shaftliner TM MILL CERTIFIED Steel-Con 00% GALVANIZED Steel Construction Systems UL Evaluation Report No. ER3660-02 Intertek The I-Stud is approved

More information

SOUND SEAL 90 DRAFT / SMOKE / ACOUSTICAL SOUND SEALANT

SOUND SEAL 90 DRAFT / SMOKE / ACOUSTICAL SOUND SEALANT PRODUCT NAME MANUFACTURER PRODUCT DESCRIPTION Sound Seal 90 Everkem Diversified Products 5180 Indiana Avenue, Winston Salem, NC 27106 PH: 1-800-638-3160 FAX: (336) 661-7969 Sound Seal 90 is a high quality

More information

Design No. U415 BXUV.U415 Fire-resistance Ratings - ANSI/UL 263. Design No. U415

Design No. U415 BXUV.U415 Fire-resistance Ratings - ANSI/UL 263. Design No. U415 Design No. U415 BXUV.U415 Fire-resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the

More information

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax: JB ENGINEERING AND CODE CONSULTING, P.C. 1661 Cardinal Drive Munster, IN 46321 Phone: 219-922-6171 Fax: 219-922-6172 E-Mail: JBEngineer@aol.com JULIUS A. BALLANCO, P.E. President January 15, 2008 Mr. Rick

More information

Construction Standards PAGE

Construction Standards PAGE Construction Standards PAGE 095113-1 SECTION 095113 - PART 1 - GENERAL 1.1 M.S.U. ISSUES 1. It the intent of MSU that all joint sealants used on its projects will comply with LEED NC 3 Credit Requirements

More information

XHBN.FF-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. FF-D-1066

XHBN.FF-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. FF-D-1066 XHBN.FF-D-1066 - http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/showpage.html?name=xhbn.ff-d-10... Page 1 of 2 9/18/2009 Page Bottom XHBN.FF-D-1066 Design/System/Construction/Assembly Usage

More information

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade Fire Protection Products Firestop Submittal Package FIP 1-Step Firestop Foam Electrical Trade Manufacturer: Fire Protection Products Ryan Fenstermaker 732.921.1503 rfenstermaker@mmm.com Electrical Products

More information

PinkWood Ltd. Revised September 29, 2017

PinkWood Ltd. Revised September 29, 2017 Fire-Rated Assemblies PR-S315 PinkWood Ltd. Revised September 29, 2017 Products: Series I-Joists PinkWood Ltd., 5929 6 th St. NE, Calgary, Alberta, Canada T2K 5R5 (403) 279-3700 www.pinkwood.ca 1. Basis

More information

BXUV.U435. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.U435. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.U435 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

System No. HW-D System No. HW-D-0262

System No. HW-D System No. HW-D-0262 8/24/2015 XHBN.HW-D-0262 - Joint Systems System No. HW-D-0262 XHBN.HW-D-0262 Joint Systems Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authoritie s Having Jurisdiction should be consulte

More information

Boise Cascade Company Revised June 25, 2018

Boise Cascade Company Revised June 25, 2018 Fire-Rated Assemblies PR-S255 Boise Cascade Company Revised June 25, 2018 Products: GPI, WI, and BSI I-Joists Boise Cascade Company, 1000 North Park Drive, Roxboro, North Carolina 27573 (336) 599-1000

More information

SUBMITTAL INDEX. Product Datasheets: Product Approvals:

SUBMITTAL INDEX. Product Datasheets: Product Approvals: Product Datasheets: HFP Pro Series Sleeve RevA HFP CD Plates RevA HFP Sleeve Extenions RevA HFP Water Dam RevA HFP Water Module RevA HFP Hollow Sleeve RevB HFP Cable Line Set RevA HFP Closet Flange RevA

More information

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11 07 21 16 Blanket Insulation Page 1 of 11 Unifrax I LLC Design No. UNI/BI 120-14 FIRE RESISTANT GREASE DUCT FyreWrap Elite 1.5 Duct Insulation ASTM E 2336-16 and ICC-ES Acceptance Criteria for Grease Duct

More information

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System 0 00/NGC NATIONAL GYPSUM COMPANY -Hour Wall System The -Hour is a -hour fire wall consisting of in. (0. mm) light-gauge steel H-Studs that secure two layers of in. (. mm) shaftliner panels friction-fit

More information

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance

CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance INFO 33, page 1 CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance HEATLINK GROUP INC R25563 4603E 13TH ST NE CALGARY, AB T2E 6M3 CANADA Types Purelink PEXa, Heatlink PEXa and

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Spandrel Glass Curtain Wall Designs Manufacturer's Representative: Rectorseal

More information

SECTION Fiber Reinforced Stucco 1

SECTION Fiber Reinforced Stucco 1 CSI SECTION 09200 FIBER REINFORCED STUCCO PART 1 GENERAL 1.01 SUMMARY A. Section Description: Provided lath and plaster where shown on the Drawings, as specified herein, and as needed for complete and

More information

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated. This Assembly Evaluation

More information

RSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP

RSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP RSIC-1 Drywall Furring Channel: Minimum Requirements: 25 gauge, hemmed edge detail required on all 25 gauge furring channel. Meets or exceeds SFIA requirements. Depth: 7/8 inch Width Bottom: 2-9/16 to

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Commercial Plumbing for PVC through Concrete Manufacturer's Representative: Rectorseal

More information

3M CS-195+ Composite Sheet Product Description

3M CS-195+ Composite Sheet Product Description Product Data Sheet 3M Product Description 3M Fire Barrier is a one-part composite system comprised of four components. The heart of the system is an organic/ inorganic, fire-resistive elastomeric sheet.

More information

FIRESTOPPING & SMOKE SEALS

FIRESTOPPING & SMOKE SEALS FIRESTOPPING & SMOKE SEALS SPECIFICATION SECTION 07860 1 General 1.1 SECTION INCLUDES.1 Comply with Division 1, General Requirements and Documents referred to therein..2 It is the intent of this section

More information

SECTION STRUCTURAL INSULATED PANELS

SECTION STRUCTURAL INSULATED PANELS SECTION 06120 STRUCTURAL INSULATED PANELS Copyright 2011-2012 Korwall Industries, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural Insulated Roof Panels. B. Structural Insulated

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIRESTOP SUBMITTAL PACKAGE HVAC Materials FS-ONE Intumesent Caulk CP 606 Acrylic Includes: Technical and Installation Data UL Certificate of Compliance LEED information MSDS UL Details Concrete Assemblies

More information

Stark Truss Company, Inc. Revised December 14, 2018

Stark Truss Company, Inc. Revised December 14, 2018 Fire-Rated Assemblies PR-S223 Stark Truss Company, Inc. Revised December 14, 2018 Products: SI-40, SI-60, and SI-80 Prefabricated Wood I-Joists Stark Truss Company, Inc. 8655 Chestnut Ridge Road, N.W.

More information

Design No. M507. Design No. M507

Design No. M507. Design No. M507 1 of 5 3/17/2015 6:22 PM Design No. M507 BXUV.M507 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted

More information

WALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01

WALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01 WALL ASSEMBLIES PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA 60-01 DESIGN NO. PMC/WA 60-01 1. Steel Framing Members (Floor, Sides, and Ceiling Runners)*: 'J'-shaped runner, minimum 2-1/2"

More information

System No. C-AJ-8048

System No. C-AJ-8048 System No. C-AJ-8048 F Rating - 2 Hr T Ratings - 0, 1/2, 3/4, 1 and 1-1/2 Hr (See Item 2) L Rating At Ambient Less Than 1 CFM / Sq. Ft. L Rating At 400 F 5 CFM / Sq. Ft. System No. C-AJ-8048 System No.

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIRESTOP SUBMITTAL PACKAGE PLUMBING Materials FS-ONE Intumesent Caulk Includes: Technical and Installation Data UL Certificate of Compliance LEED information MSDS UL Details Gypsum Wall Assemblies W-L-1054

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower Spokane, WA I-Stud and CertainTeed Shaftliner MILL CERTIFIED 00% GALVANIZED UL Evaluation Report No. ER3660-02 Intertek SCAFCO I-Stud is approved with the following

More information

Fire Barrier 3000 WT Intumescent Silicone Sealant

Fire Barrier 3000 WT Intumescent Silicone Sealant Fire Barrier 3000 WT Intumescent Silicone Sealant Product Data Sheet Date: May 2016 Supersedes: January 2015 Product Description & Intended Use 3M Fire Barrier 3000 WT Intumescent Silicone Sealant firestops

More information

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version) M Fire Barrier Duct Wrap + Product Data Sheet and Installation Guide (Condensed Version) FIRE BARRIER UP TO Fire Protection HOUR FLEXIBLE WRAP GREASE & AIR DUCT Fire Protection. Product Description M Fire

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Gypsum board screw attached to wood framing and furring members, joint treatment, and accessories. 2. Installation of

More information

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated. This Assembly Evaluation

More information

Fire Protection Products

Fire Protection Products wwww Fire Protection Products Product Data Sheet April / 2017 Product Description Product Features Applications Specifications 3M Fire and Water Barrier Tape is a self-adhered membrane that provides a

More information

TECHNICAL DATA SHEET ASMACO INTUMESCENT ACRYLIC SEALANT

TECHNICAL DATA SHEET ASMACO INTUMESCENT ACRYLIC SEALANT TECHNICAL DATA SHEET ASMACO INTUMESCENT ACRYLIC SEALANT (HIGH PERFORMANCE GUN GRADE INTUMESCENT FIRE-STOP ACRYLIC SEALANT) DESCRIPTION: ASMACO INTUMESCENT ACRYLIC SEALANT is a single component high performance

More information

SHAFTWALL & AREA SEPARATION WALL SYSTEMS PRODUCT CATALOG

SHAFTWALL & AREA SEPARATION WALL SYSTEMS PRODUCT CATALOG SHAFTWALL & AREA SEPARATION WALL SYSTEMS PRODUCT CATALOG 100% American-Owned and Operated marinoware.com THE BEST PRODUCTS, QUALITY, AND CUSTOMER SERVICE. Our large inventory of both finished products

More information

Geometrik Manufacturing Inc.

Geometrik Manufacturing Inc. PRODUCT: GEOSQUARE WOOD TILES Page 1 PART I GENERAL 1.1 SECTION INCLUDES 1. GeoSquare wood [acoustical] ceiling tiles. 2. Coordination with other trades that have parts attached to, penetrate through or

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2996 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 07 00

More information

ACOUSTICAL WALL TREATMENT SECTION 09840

ACOUSTICAL WALL TREATMENT SECTION 09840 ACOUSTICAL WALL TREATMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Site-fabricated, stretched fabric acoustical wall system built with rigid polymer stretching system to secure fabric over the wall

More information

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES SECTION 09 21 16.23 (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shaft Enclosures 2. Chase Enclosures 3. Stair Enclosures B. Related Sections: 1.02 DEFINITIONS

More information

SECTION FIRE RESISTIVE JOINT SYSTEMS

SECTION FIRE RESISTIVE JOINT SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 07 84 43 FIRE RESISTIVE JOINT SYSTEMS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

The GlasRoc Shaftliner Type X advantage...

The GlasRoc Shaftliner Type X advantage... C e r t a i n T e e d SHAFTLINER F o r A r e a S e p a r a t i o n F i r e w a l l s Shaftliner S Type X for Area Separation GlasRoc Shaftliner is a specially formulated product for applications where

More information

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications. SECTION 09.22.16 NON-LOAD BEARING WALL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Non-load bearing metal studs for wall assemblies. B. Area Separation and shaft wall framing products. 1.2 RELATED SECTIONS

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4073 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

Firestop and Fire Protection Systems

Firestop and Fire Protection Systems Firestop and Fire Protection Systems Leading-edge Technology. Outstanding Service. 156 Firestop sealants and sprays Elastomeric silicon sealant CP 601S Flexible firestop sealant CP 606 Firestop sealant

More information

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS SECTION 07841 - THROUGH-PENETRATION FIRESTOP SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax Thermasheath-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam

More information

SECTION SOUND-ABSORPTIVE PANELS

SECTION SOUND-ABSORPTIVE PANELS SECTION 09 77 23 SOUND-ABSORPTIVE PANELS PART 1 - GENERAL 1.1 CONDITIONS AND REQUIREMENTS A. The General Conditions, Supplementary Conditions, and Division 01 General Requirements apply. 1.2 SECTION INCLUDES

More information

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System -Hour Wall System The -hour Wall System is a -hour fire wall consisting of two layers of in. (. mm) shaftliner panels friction-fit between in. (0. mm) light-gauge steel H-Studs and a layer of /" Fire-Shield

More information

138 H-STUD AREA SEPARATION WALL SYSTEM

138 H-STUD AREA SEPARATION WALL SYSTEM H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic fashion by the results of this actual townhouse fire in which the two-hour fire-rated

More information

Guide Specification for the OSI QUAD Window and Door Flashing System

Guide Specification for the OSI QUAD Window and Door Flashing System Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIESTOP SUBMITTAL PACKAGE Flat Slab Sealant Project: Date: Submitted by: 210 Evans Way Somerville, NJ 08876 (800) 992-1180 (908) 526-8000 Fax (908) 526-9623 www.stifirestop.com GENEAL CETIFICATE OF CONFOMANCE

More information

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction. HACKER SOUND MAT II HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction. HACKER SOUND MAT II, a recycled rubber sound

More information

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL SECTION 09511 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

F I R E M A N A G E M E N T P R O D U C T S DEFLECTION

F I R E M A N A G E M E N T P R O D U C T S DEFLECTION F I R E M A N A G E M E N T P R O D U C T S DEFLECTION FIRE FIRE AIR AIR SOUND SOUND w w w. c e m c o s t e e l. c o m FAS TRACK S ENVIRONMENTAL BENEFITS AND LEED CONTRIBUTIONS FAS Track represents an

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL-FIBER FIREPROOFING REPORT HOLDER: THERMAL CERAMICS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL-FIBER FIREPROOFING REPORT HOLDER: THERMAL CERAMICS, INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2213 Reissued 04/2018 This report is subject to renewal 04/2019. DIVISION: 07 00

More information

Geometrik Manufacturing Inc.

Geometrik Manufacturing Inc. PRODUCT: GEO SYSTEM Page 1 PART I GENERAL 1.1 SECTION INCLUDES 1. Linear Acoustical Wood Ceiling System including suspension hardware by Geometrik Manufacturing Inc. 2. Coordination with other trades that

More information