Brisbane Domestic Terminal Wayfinding Signage Manual

Size: px
Start display at page:

Download "Brisbane Domestic Terminal Wayfinding Signage Manual"

Transcription

1 Brisbane Domestic Terminal Wayfinding Signage Manual Brisbane Airport Corporation Pty Ltd Final Issue C December 202

2 FOREWORD This manual describes the wayfi nding signage at the Brisbane Airport Domestic terminal. The aim of the signage system is to ensure that all wayfi nding signs meet the quality standards of aesthetic appeal, uniformity and simplicity while being highly functional in providing effective wayfi nding. There is currently a specifi c set of issues that need to be addressed. These include: preventing uncontrolled ad hoc signage being produced decluttering the environment removing unnecessary signage meeting current compliance with the Disability (Access to Premises Buildings) Standards 200 The manual is to be used for ongoing management and maintenance of the sign system.

3 CONTENTS Section A Wayfinding Strategy Wayfi nding Principles A- Accessibility A-2 Capability Statement - Philip Chun A-3 Section B Sign Selection Guide Overview B- Sign Types Summary B-2 B-8 Section C Graphic Standards Nomenclature C- Font C-2 Pictograms C-3 Arrows C-6 Colour Reference C-8 Section D Sign Types S4.3 Gate Marker D- S4.6 Freestanding Accessible Directional Sign D-3 S5. Wall Mounted Panel D-5 S5.2 Wall Mounted Panel D-6 S5.3 Information Lift Directory D-7 S5.4 Wall Mounted Accessible Directional D-9 S6. Multi Directional Sign Type D-0 S7. Primary Directional - Suspended Sign D-2 S7.2 Primary Directional - Two Sided Cantilivered Sign D-6 S8. Secondary Directional - Suspended Sign D-8 S8.2 Secondary Directional - Cantilevered Sign D-23 S9.2 Tertiary Directional - Cantilevered Sign D-25 S0. Facility Door Sign D-27 S0.3 Glazed panel safety decal D-29 S2.5 Facility Supergraphic D-30 S3. Gate Marker D-3 S3.2 Minor Identifi cation Amenity Signage D-33 S20 Operational Signage D-37 S2 Operational Signage D-4 Section E Appendix Sign Location Plans E- Sign Schedule E-4 Section F Sign Specifications

4 INTRODUCTION This signage manual illustrates and specifi es all of the signage types required for effective wayfi nding at the Brisbane Domestic Terminal. These sign types are divided into various categories based on function. This manual is divided into sections to assist in the understanding of all the elements that make up an effective wayfi nding system. It describes the principles of the wayfi nding strategy, and provides a sign selection guide and the visual graphic standards and details each sign type. A typical sign location plan and sign schedule is prepared in Section E. Review and Approvals Process It is vital to ensure that the signage provided for each project provides effective wayfi nding in the termninal. It is envisaged that proposals are assessed and approved by Airport personnel familiar with facility operations, particularly in respect to site accessibility, to ensure the effectiveness of the overall wayfi nding signage of the facility is maintained. Guidance may also be sought from an access consultant once a wayfi nding design package is developed.

5 Wayfi nding Strategy Wayfinding Principles Accessibility A

6 SECTION A WAYFINDING PRINCIPLES The fundamental principles of the wayfi nding signage uses the progressive disclosure technique of providing information. This helps to maintain the focus of a visitor s attention by reducing clutter and confusion, and cognitive workload. This improves the legibility of the signs by presenting only the minimum amount of information required to get to the next decision point. These principles are as follows: Identify the check-in counters identify all lifts and stairs identify all other facilities such as toilets, parents rooms and fi rst aid rooms Identify all services and processes provide directional signs to all of the destinations identifi ed above, in a hierarchical list based on distance, i.e. closest destination is listed fi rst) show accessible paths to destinations, if different from main pathway maintain a hierarchical level of information for the user provide other signage that regulates behaviour and activities when required when directing to exit, provide direction to main building entrance use internationally recognised pictograms and English text all names and terms to be consistent, user friendly and easily understood continue the signage through the whole visitor experience from arrival to exit. International Guidelines (ICAO, Third Edition 993) The following principles must also be considered as part of the ongoing development of the terminal Wayfi nding signs should not be obscured by obstructions or have to compete with advertising or other signs, and Readability should not be sacrifi ced to décor or aesthetics To ensure the performance and visibility of wayfi nding signs, BAC must maintain the environment affecting users of the site. This will eliminate any potential obstructions. Key Objectives and Approach to Wayfinding The objectives of the signage/wayfi nding package are to support wayfi nding and the orientation and mobility of all users to and within the Airport facilities, and to enable all users to effectively orientate themselves and identify accessible paths of travel and Airport features, amenities and areas of interest including: all amenities (e.g. accessible sanitary facilities, lifts) which may be of particular importance for people with a disability, travellers facilities (e.g. luggage trolley bays, car park payment machines) safety features. A holistic, facility wide approach is required to signage, wayfi nding, orientation and mobility. The signage/wayfi nding system is required to work in conjunction with orientation cues and legibility of the Airport which shall be affected by additional factors, including: the layout and planning of the facility (e.g. fl oor plan layout), transparency and sightlines within the facility (e.g. long range views, glazing elements). architectural features and landmarks (which may include visual, tactile and acoustic cues and features such as supergraphics), and colours, fi nishes and materials of building elements (e.g. colour contrast between elements such as walls and fl oors, changes in fl oor fi nishes such as from ceramic tiles to carpet). It is recommended that an overarching legibility and wayfi nding strategy be undertaken in order to maximise the effectiveness of the signage/wayfi nding package. This includes ways in which the installed signage may effectively support and work in conjunction with: the existing planning/architectural features (e.g. building/facility layout and sightlines), interior design features (e.g. supergraphics), airport management and operational policies and procedures (e.g. accessible pick-up and set-down areas, accessible car parking), both permanent and temporary signage, the totality of the installed signage within the facility A-

7 SECTION A ACCESSIBILITY Design Standards The design standards ensure that signage installations shall meet or exceed the minimum requirements of Part H2 of the Disability (Access to Premises - Buildings) Standards 200. Hence AS 428. (2009) has been adopted in lieu of AS 428.(200) as specifi ed by Part H2. In addition the requirements of AS 428.2(992) with regard to the location of signage with respect to decision points and mounting locations with the exception of overhead signage (e.g. primary directional sign S7.). The following describes the standards that the signage design is based on. Locating Signage Airport travel may be a time of anxiety and stress for some users. It is important that users are not presented with misguided information that leads them in the wrong direction. This may not only create frustration and stress, but waste a person s limited energy reserves. Therefore, it is important that a successful wayfi nding/signage system supports all users in a manner consistent with the spirit and intent of the Disability Discrimination Act. The signage system is to minimise any anxiety or confusion experienced by users unfamiliar with the Airport environment. To this effect, signage must be clear, consistent and concise and incorporate the following: The signage scheme must be concise with only the required signage installed to support users. It is important that the amount of visual information provided is manageable and not overwhelming to users. Redundant signage and visual clutter should be avoided. Sign faces must have low refl ectivity of ambient light. Signage shall be located at reasonable and appropriate decision making points along paths of travel in order to support and reassure users. At points such as T intersections it may be appropriate to locate signage in opposing directions such that they are readily apparent by people travelling in both directions towards the intersection. Signage to be located with consideration to: - the direct paths of travel which users shall take through the facility - decision making points along paths of travel - ensuring signage itself does not create a hazard (e.g. overhead FIDS screens) - the installed signage is not obstructed during Airport operations. Signage of the same type to be mounted at consistent heights. Wall and fl oor mounted signage designed to be viewed at eye level must be located such that it is visible for both seated and standing adults in accordance with AS (992) Figure 30. Refer to Figure 30 (left) Zones for Viewing and Common Viewing. AS (992). Room signage to be located on the latch side of the door with the leading edge of the signage located between mm from the architrave. - Where it is not possible, room signage may be located on the door itself, however this should be avoided as placing room signage on doors greatly reduces the effectiveness of the sign when the door is open. Identifi cation signage designed to be viewed at eye level should be located such that it is visible for both seated and standing adults in accordance with Figure 30 (left) AS (992).. Final signage locations are to be verifi ed on site and to be approved by Airport personnel with an understanding of facility operations, particularly in respect to site accessibility (e.g. the locations of accessible facilities and procedures which may be in place to support users with a disability). Mandatory Signs In order to meet BCA 202 requirements, the following signage is required as a minimum all sanitary facilities, including accessible and ambulant disabilities. where a bank of sanitary facilities is not provided with an accessible sanitary facility, directional signage at the bank of sanitary facilities to locate the nearest accessible sanitary facility. where a pedestrian entrance is not accessible, directional signage at the inaccessible entrance to locate the nearest accessible pedestrian entrance. where a room containing a hearing augmentation system is provided. to each passenger lift. at each accessible car parking space. Accessible Zone Accessible text zone and permissible accessible text zone are the allowed areas where tactile text and Braille should appear on any sign, so that it can be read (sensed) by disabled people sitting in a wheelchair without being too low for visually impaired people who are standing by the sign. Design Codes and Data References Signage will conform to the following design standards for access and mobility: AS General requirements for access - New building work AS Enhanced and additional requirements - Buildings and facilities AS Tactile indicators Building Code of Austratlia BCA 20 Clause D3.6, Clause H2.0 Disability Discrimination Act 992 (DDA) Disability Standards for Accessible Public Transport 2002 (DSAPT) Disability (Access to Premises - Buildings) Standards 200 (The Premises Standards). Note: Part H2 applies AS (200) Design for access and mobility Part 5: Communication for people who are deaf or hearing impaired AS (999) Lifts, escalators and moving walks Part 2: Facilities for persons with disabilities International signs to provide guidance to persons at airports and marine terminals (ICAO, third edition, 993). A-2

8 SECTION A ACCESSIBILITY A-3

9 Sign Selection Guide Sign Types Summary B

10 SECTION B SIGN SELECTION GUIDE Overview This section illustrates the typical process in selecting the correct type of sign for the required message. Signs have been categorised into sign types based on their primary purpose. Signs have been categorised based on the type of message they convey. The sign types fi t within the following groups. Identifi cation Signs Directional Signs Information Signs Regulatory Signs Statutory Signs Signs that are the same type but have minor differences are identifi ed by a numerical suffi x (eg. S7., S7.2, etc). B-

11 Airtrain Buses & Coaches Car Park Lift To Terminal Airtrain, Buses & Coaches, Car Park terminal BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION B S SUMMARY DIRECTIONAL SIGNS NAME SIGN USE TYPICAL CONTENT LOCATION S4.6 Secondary Accessible Directional Sign Departures Gates Café & Bar Lift to Departures SAFETY CONTENT SUPPLIED BY BAC S5.4 Accessible Directional Sign Wall Mounted S6. Multi-sided Suspended Directional Sign Arrivals / departures Arrivals / departures B-2

12 SECTION B S SUMMARY DIRECTIONAL SIGNS NAME SIGN USE TYPICAL CONTENT LOCATION S7. Primary Directional Double Sided Suspended Gates Café Parents Room Toilets & Showers S7.2 Primary Directional Double Sided Cantilevered Airtrain Buses & Coaches Car Park Rental Cars Public Pick Up S8. Secondary Directional - Double Sided Suspended Car Park Payment Way out Pre booked ground transport B-3

13 SECTION B S SUMMARY DIRECTIONAL SIGNS NAME SIGN USE TYPICAL CONTENT LOCATION S8.2 Airtrain Buses & Coaches Car Park Rental Cars Public Pick Up Secondary Directional - Double Sided Cantilevered S9. Tertiary Directional Double Sided Suspended Baggage claim Exit Toilets S9.2 Baggage claim Toilets Exit Tertiary Directional Double sided Cantilevered B-4

14 Security Restricted Area Unauthorised entry prohibited Maximum penalty exceeds $5,000 Australian Transport Security Act 2004 and Aviation Transport Security Regulation 2005 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION B S SUMMARY IDENTIFICATION SIGNS NAME SIGN USE TYPICAL CONTENT LOCATION S4.3 Gate Marker - CUS WARNING Passengers only No smoking Passengers only No smoking S0. Room Identification Sign - Facility Identification Unisex Toilet LH & Shower S0.3 Glazed Panel Safety Decal B-5

15 Mechanical Plant.E.23 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION B S SUMMARY IDENTIFICATION SIGNS NAME SIGN USE TYPICAL CONTENT LOCATION S3. Gate Marker - Suspended 29 S3.2 Minor Identification Sign - Cantilevered S20 Operational Signage Protective earwear required B-6

16 .E.23 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION B S SUMMARY IDENTIFICATION SIGNS NAME SIGN USE TYPICAL CONTENT LOCATION S2 Room Identification FIRE HOSE REEL B-7

17 2 Bridge Arrivals Authorised access only BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION B S SUMMARY LOCATION S5. Operational Information Wall Mounted Large Panel SOS Duress alarm S5.2 Operational Information Wall Mounted Small Panel S5.3 Information - Lift Directory you are on the bridge link. lift access to level 3 airtrain B-8

18 Graphic Standards Nomenclature Font Pictograms Arrows Colour Reference C

19 SECTION C GRAPHIC STANDARDS Nomenclature TERMINAL RETAIL SERVICES FACILITIES Nomenclature relates to the wording of the signs, as well as the tone of the messages. It should be applied consistently throughout the airport. Brisbane Domestic Brisbane International Arrivals Shopping Food Court Café Currency Exchange ATM Telephones Male Toilet Female Toilet Unisex toilet An approved list of common facility names and typical messaging has been developed to maintain a consistent language throughout the airport signage. This nomenclature needs to be used consistently not only on the signs, but also in all communications, web sites and used by all staff working at the terminal. Departures Bar Restaurant Information Ticketing Parents Room Showers Languages Fashion Meeting Point Change Roooms All signs to be in English only. News & Books Souvenirs Administration Offices Internet Baby Change Although there are many international visitors at the terminal, we do not recommend including other languages, since it is diffi cult to determine which languages to include or which to exclude. PROCESSING Check-in Transit Passengers Security Gifts and Giftware Visitor Information Accomodation Baggage Services Oversize Baggage Baggage Wrap TRANSPORT Car Park Airtrain Bus The introduction to other languages will also signifi cantly reduce legibility and signifi cantly increase the size of the signs. Baggage Claim Taxi Oversize Baggage Car Rentals Limousine Pre-booked Transport Tour Groups Police TBus C-

20 SECTION C GRAPHIC STANDARDS ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz Signage Fonts Zurich BT The font Zurich BT is to be used on all signage. Cap X-height This refers to the measurement noted on the sign type drawings for the height of text. This is always shown in millimetres unless otherwise stated. Type heights relative to each sign type are detailed in the sign type drawings. ZURICH BT ROMAN ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz ZURICH BT BOLD Gate 28 ZURICH BT ROMAN GgXx CAP X-HEIGHT X Legibility Guide for Text (AS ) Viewing distance 2m 4m 6m 8m 2m 5m 25m 35m 40m 50m Minimum cap X height 6mm 2mm 20mm 25mm 40mm 50mm 80mm 00mm 30mm 50mm C-2

21 SECTION C GRAPHIC STANDARDS Pictograms PARKING CARS BUSES TRAINS LIMOUSINE TAXI Pictograms for use on all communications and signage are as illustrated. Pictograms apply to the commonly used facilities and services and are grouped into the following categories. Facilities and Services Hospitality Vertical Movement Transport Accessible Features RENTAL CARS PRIVATE PICK UP GROUND TRANSPORT MALE FEMALE ACCESSIBLE Regulation These pictograms are from the suite known as International Symbol Signs System, developed by the American Institute of Graphic Arts (AIGA) and Society of Environmental Graphic Design (SEGD). This suite has been adopted in many countries and are recognised world wide. Pictograms can generally be understood as stand alone messages. These may also be supported with English text, where shown on the sign type drawings. BABY CHANGE UNISEX FEMALE & MALE FEMALE AMBULANT TOILET MALE AMBULANT TOILET HEARING AUGMENTATION TELEPHONE CAFE FOOD OVERSIZE BAGGAGE STROLLERS USE FIRE STAIR Legibility Guide for Pictograms (AS ) Viewing distance < 7m 7-8m 8 > Minimum height 60 x 60 mm 0 x 0 mm 200 x 200 mm FIRE HOSE REEL FIRE HOSE REEL 2 FIRE EXTINGUISHER FIRE EXTINGUISHER 2 FIRE HOSE USE FIRE STAIR 2 Note: Text shown below each pictogram is for reference and identifi es the correct pictogram. It is not to be used as part of the pictogram. C-3

22 SECTION C GRAPHIC STANDARDS FIRE STAIR CCTV EMERGENCY PHONE FIRE HOSE FIRE HOSE 2 FIRST AID SECURITY CAMERAS INFORMATION DRINK FOUNTAIN LITTER RECYCLING TERMINAL INTERNATIONAL TRANSFERS P29 FLIGHT INFORMATION BAGGAGE LOCKERS AIRTRAIN BAGGAGE TROLLEYS CUSTOMS LOST & FOUND ESCALATOR ESCALATOR UP ESCALATOR DOWN STAIRS STAIRS UP STAIRS DOWN LIFT INTERNATIONAL TRAVELATOR MOVING WALKWAY HEAVY AND OVERSIZED LUGGAGE Note: Text shown below each pictogram is for reference and identifi es the correct pictogram. It is not to be used as part of the pictogram. C-4

23 SECTION C GRAPHIC STANDARDS PERSON WALKING TAKE TICKET TROLLEYS EMERGENCY EXIT (LEFT) EMERGENCY EXIT (RIGHT) NO PARKING SMOKING ALLOWED NO ENTRY ENTRY HOTEL NO RUNNING POST OFFICE TRUCKS PHARMACY CROSSWALK NO SMOKING CREDIT CARD TICKET SALES SHOWER SHOWER 2 CHECK-IN BAR SHOPPING ATM Note: Text shown below each pictogram is for reference and identifi es the correct pictogram. It is not to be used as part of the pictogram. C-5

24 SECTION C GRAPHIC STANDARDS Arrows This page illustrates the correct arrow to be used and its typical applications on signs. The Brisbane Domestic Terminal Arrow This arrow type is to be used for all directional signs, across all areas. STRAIGHT AHEAD Placement of Arrow When the message is directing left, the arrow is always to be on the left side of the sign. When the message is directing right, the arrow is always to be on the right side of the sign. UP LEFT NEXT UP RIGHT NEXT LEFT NEXT RIGHT NEXT DOWN LEFT NEXT DOWN RIGHT LAST VERTICAL FORMAT C-6

25 SECTION C GRAPHIC STANDARDS ARROWS CONTINUED This page illustrates the correct arrow to be used and its typical applications on signs. ALLOWABLE ALTERNATIVES LEFT ARROW ALWAYS LEFT ALIGNED RIGHT ARROW ALWAYS RIGHT ALIGNED HORIZONTAL FORMAT C-7

26 SECTION C GRAPHIC STANDARDS SIGNAGE COLOURS Colour Reference This schedule specifi es the colours to be used in all signage. Colours have been adjusted to suit the available standard paint, and vinyl colours. WHITE Dulux Natural White PCWF5/737 Perspex FROST - Polar White BLACK Dulux Domino PGA8 3M Matt Black Grey Dulux Timeless Grey PGF4 Colour Strategy Colours have been chosen to achieve a high level of contrast and legibility as well as to achieve continuity with the existing external signage system. Generally all signs appear as charcoal text on white background, with a white frame or backing. Finish Painted fi nish to be Satin. All signage to have low refl ectivity to minimise glare. PICTOGRAM COLOURS First Aid Green Pantone 356C AS2700 Homebush Green G27 Avery Meadow Green 966 Regulatory Red Pantone 485C AS2700 Signal Red R3 Avery Signal Red 925 Access Blue Avery Translucent Sailing Blue 5549 QM Non-illuminated Access symbol Ultramarine AS2700, Avery Supercast 'Vivid Blue 934 Pantone 2945 C-8

27 Sign Types Information Sign Directional Sign Identification Sign Statutory Sign Regulatory Sign D

28 Security Restricted Area Unauthorised entry prohibited Maximum penalty exceeds $5,000 Australian Transport Security Act 2004 and Aviation Transport Security Regulation 2005 Security Restricted Area Unauthorised entry prohibited Maximum penalty exceeds $5,000 Australian Transport Security Act 2004 and Aviation Transport Security Regulation 2005 Security Restricted Area Unauthorised entry prohibited Maximum penalty exceeds $5,000 Australian Transport Security Act 2004 and Aviation Transport Security Regulation 2005 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION D S S4.3 Gate Marker Sheet of 2 Construction Details Refer notes on drawing ALIGN ALIGN ALIGN WARNING WARNING WARNING Passengers only No smoking Passengers only No smoking Passengers only No smoking Passengers only No smoking ALIGN ALIGN ALIGN Single Gate Marker Typical Elevations Scale :50 S4.3 Gate Identification and operational information. Refer to Sheet 2 for setout details. Double Gate Marker D-

29 SECTION D S S4.3 Gate Marker Sheet of 2 0 TOP VIEW Construction Details Refer notes on drawing Numbers to be aligned 0 29 to vertical centre of protruding wall variable 450 portal extent 0mm black satin acrylic, Perspex Frost Charcoal Dusk, laser cut number. Spray to rear face only of acrylic to achieve opaque aesthetic. Conceal fixed to continuous spacer of same acrylic FRONT VIEW SIDE VIEW Graphic Layout Scale :5 D-2

30 SECTION D S 0mm radius corners 2 S4.6 Freestanding Accessible Directional Sign Sheet of Braille & tactile zone Departures Gates Café & Bar Lift to Departures SAFETY CONTENT SUPPLIED BY BAC Lift to Departures Departures Gates Café & Bar SAFETY CONTENT SUPPLIED BY BAC Construction Details. Fabricated 75 x 75 x 3mm RHS post & internal support frame with fully welded base plate. Cap frame with 6mm plate. Primed and powdercoat fi nished. 2. 3mm thick painted fabricated aluminium face cladding, powdercoat fi nish with front applied vinyl graphics. Sign maker to provide adequate support ie 6mm thick plywood backing to strengthen panel. Folded returns fi xed with counter sunk stainless fi xings. Paint out heads to match panel colour. FOOTING OPTIONS 3. Reinforced concrete pad footing (where no slab is available) to engineers specifi cations. 4. Chemset anchors to existing concrete slab. Conceal all fi xings within sign frame. 5..6mm thick aluminium sign panel..0mm.5mm raised Trezzini graphics and letters, all edges to be rounded. Grade Braille, ball bearing domes located 8mm below letters. Braille locator notch left of fi rst line of Braille. Text letters and pictograms laser cut and then glued into laser cuts in panel surface. Ball bearing domes inserted into holes cut into back of the sign. 6. Mounting surface. Prepare surface free from dust, dirt, oil & grease prior to fi xing. Sign panel adhered twith 3M VHB double sided tape & silicone. NOTE: All structural members, fi xings and footings to be confi rmed by sign maker s engineer. panel to cladding as required to stiffen. Typical Elevation D-3

31 SECTION D S S4.6 Freestanding Accessible Directional Sign Sheet 2 of 2 Graphics Detail FONT All Text = Zurich BT Roman SIZE Text = 75mm cap X height (22m max viewing distance) COLOUR Panel colour = Dulux Natural White PCWF5/737 Frame = Dulux Natural White PCWF5/737 Graphics = Matt Black Note CL Departures Gates Café & Bar Refer to sheet of 2 for Construction details 05 min. clearance CL Lift to Departures 50 0 escalators to departure gates 25-38, cafe & bar lift to departures 2mm min. gap between letters Typical Elevation D-4

32 SECTION D S S5. Wall Mounted Panel Sheet of EQ 20 EQ SOS Note: wall colour and sign panel colour to have minimum 30% contrast. Construction Details Sign panel applied to solid surface..2mm thick aluminium panel. 2 pack paint fi nish on all visible surface with screen printed graphics. Sign panel applied to glazing 2..2mm thick aluminium panel. 2 pack paint fi nish on all visible surface with screen printed graphics. 3..2mm thick aluminium panel with 2 pack painted fi nish on all visible surfaces. Rear blank panel rear mounted to glazing as blank. Typical fi xing Zuricht BT 80pt on 80pt leading 75 SOS Duress alarm 4. Panels to be conceal adhesive fi xed to surface with double sided VHB adhesive. Panels to be free of distortion or warping when applied to surface. All surfaces adhesive fi xed to be prepared to manufacturers specifi cation. FINISH All panels to be spray painted with clear antigraffi ti top coat, Satin fi nish. Samples are to be provided prior to manufacture. Graphics Detail FONT 20 Duress alarm Type/graphic exclusion zone 275 All Text = Zurich BT Roman SIZE Text = As shown COLOUR Panel = Dulux Natural White PCWF5/737 Text = To match 3M Matte Black vinyl SOS Backround = Avery Signal Red to FFL 0 Elevation S5. CUS Duress alarm Scale :2 02 Elevation S5. CUS location setout Scale :20 D-5

33 Authorised BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION D S S5.2 Wall Mounted Panel Sheet of Construction Details Sign panel applied to solid surface..2mm thick aluminium panel. 2 pack paint fi nish on all visible surface with screen printed graphics. Sign panel applied to glazing mm thick aluminium panel. 2 pack paint fi nish on all visible surface with screen printed graphics. 3..2mm thick aluminium panel with 2 pack painted fi nish on all visible surfaces. Rear blank panel rear mounted to glazing as blank. access only Typical fi xing Panels to be conceal adhesive fi xed to surface with double sided VHB adhesive. Panels to be free of distortion or warping when applied to surface. All surfaces adhesive fi xed to be prepared to manufacturers specifi cation. Authorised access only 275 FINISH All panels to be spray painted with clear antigraffi ti top coat, 30% gloss level. TBC Samples are to be provided prior to manufacture. Graphics Detail FONT 0 Elevation S5.2 CUS Scale :2 02 Elevation S5.2 CUS location setout Scale :20 All Text = Zurich BT Roman SIZE Text = As shown COLOUR Panel = Dulux Natural White PCWF5/737 Text = To match 3M Matte Black vinyl D-6

34 2 Offices Check-in Baggage Claim Oversize Baggage BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION D S 00 S5.3 Information Lift Directory Sheet of Typical Location Braille and tactile panel mounted to wall Construction Details. Raised Braille tactile lift directory.6mm thick painted aluminium panel all edges to be rounded. Grade Braille to BCA and AS428. requirements, ball bearing domes located 8mm below letters. 2. Screen printed background applied to panel surface. Text and pictograms laser cut and then glued into laser cut shapes in panel surface. 20 FINISH 2 Departures Gates tactile text and arrow 2 Offices All panels to be spray painted with clear antigraffi ti top coat, 30% gloss level. TBC 3. Panels to be conceal adhesive fi xed to surface with VHB adhesive. Panels to be free of distortion or warping when applied to surface. All surfaces to be adhesive fi xed to be prepared to adhesive manufacturers specifi cation. 250 min. Check-in Baggage Claim Oversize Baggage Check-in Baggage Claim Oversize Baggage INSTALLATION ON GLASS 4. Back of panels fi xed to glass MUST be painted. 5. Apply optically clear double sided tape to back of panel to ensure fi xings are not visible from back. Samples are to be provided prior to manufacture. Graphics Detail Braille message: lift up to departures FONT All Text = Zurich BT Roman SIZE As shown COLOUR Panel & Text = Dulux Natural White PCWF5/737 Typical Graphic Layout Braille message: Black background = Dulux Domino PGA8 Grey background = Dulux Timeless Grey PGF4 D-7

35 SECTION D S S5.3 Information Lift Directory Sheet 2 of 2 General Construction Notes Refer to sheet for construction and graphics detail Departures Gates tactile text and arrow 2 Offices Arrivals 250 min. Check-in Baggage Claim Oversize Baggage Check-in Baggage Claim Oversize Baggage Braille message: Graphic Layout Braille message: D-8

36 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION D S S5.4 Wall Mounted Accessible Directional Sheet of Departures Gates clearance from edge of wall/ door frame lift to departure gates CL Offices Offices Lift to Departures 05 min. clearance 55 CL General Construction Notes Refer to S5.3 Sheet for construction and graphics details CL Lift to Departures Graphic Layout lift to level 2 offices lift to departures Typical Elevation Sign location to suit site conditions D-9

37 SECTION D S 37 Extruded metal edge cap at vertical sides of signform. Line of LED lighting subframe as required. Minimum 25 mm from face of sign panel. LED units to be secure fixed to a lighting units to be removed from signform for servicing. Top/base cap to be removable to allow servicing. S6. Multi Directional Sign Type Three Sided Suspended Sheet of 2 Construction Details 740 Perspex sign panel custom moulded. Refer to drawing notes FINISH Typical Elevation Section NOM 350 Fabricated structural frame for signform. to each external face for LED support (minimum) as required 25 (minimum) Typical Plan Section as required. 0 ST705 similar All panels to be spray painted with clear antigraffi ti top coat, 30% gloss level. TBC Samples are to be provided prior to manufacture. Graphics Detail FONT All Text = Zurich BT Roman SIZE All text = 60mm cap X height COLOUR Panel colour = White (colour tbc) Lift to Airtrain Car Park Public Pick Up Travelator to Airtrain Buses & Coaches Rental Cars Public Pick Up Arrivals / Departures Arrivals / Departures Sign face = Perspex Frost colour polar white End caps = White (colour tbc) Access Symboi = Avery Translucent Sailing Blue 5549 QM Text and Pictograms = 3M Matt Black vinyl Arrivals / Departures Arrivals / Departures NOTE Text shown is distorted to suit curvature of face Arrivals / Departures Arrivals / Departures Graphics to be 3M external grade opaque vinyl. Text must be replaced with out distortion 700 End View Typical Elevation D-0

38 SECTION D S S6. Multi Directional Sign Type Three Sided Suspended Sheet 2 of 2 Construction Details Refer to drawing Sheet for graphics and construction details. 740 to rafter Ø65mm nom Arrivals / departures Arrivals / departures D 2350 Grid D Sign L2.004 Grid D Sign L2.004 D-

39 SECTION D S 3300 nom C Sheet 4 similar B Sheet 3 S7. Primary Directional Two Sided Suspended Sign Sheet of 5 Qantas Check-in Airline Check-in Virgin Australia Check-in Construction Details. Illuminated sign box manufactured to specifi cation with front applied vinyl graphics. 700 Samples are to be provided prior to manufacture. Graphics Detail FONT All Text = Zurich BT Roman SIZE Text = 55mm Cap X height B Sheet 3 similar 8 airlines shown Allowance for 2 off maximum similar B Sheet 3 Pictograms = As per layout COLOUR Text and Pictograms = 3M Matt Black vinyl NOTE: As part of the Multi-level car park signage package Frost Design prepared alternative manufacturing intent of the formed signs. Gates Café Parents Room Toilets & Showers Refer to Sheet 6 and 7 or details for costing purposes A Sheet 2 Typical Elevations D-2

40 SECTION D S Minimum 25 mm from face of sign panel. Perspex sign panel, custom moulded. S7. Primary Directional Two Sided Suspended Sign Sheet 2 of Sheet 5 25 (minimum) 25 (minimum) similar 0 as required 6 Sheet 5 Construction Details Refer drawing notes Samples are to be provided prior to manufacture. Graphics Detail Refer to Sheet for details. Section A 344 (nom) where required. 700 A - Typical Elevation - Internal frame for signform. support. structural frame. D-3

41 SECTION D S Gates Café Parents Room Toilets & Showers Typical Elevation 2350 S7. Primary Directional Two Sided Suspended Sign Sheet 3 of 5 Construction Details Refer drawing notes Samples are to be provided prior to manufacture. Graphics Detail 2 Detail 2 - Acrylic / Aluminium 6 x x x x x x x 3 face to sign capping Paint all solid internal surfaces white or Film as required at regular spacing unless an is recommended. x x x x x x x with a secure fixing plane. allow access to lighting components. extrusions for sign carrier. shadowing. Refer to Sheet for details. fixed to angle trim as indicated. Perspex Angle trim as required to surface to perspex sign panel. Mechanical fix to structural frame as required. from sign panel. Section B - S7.- Typical Top Cap and Base Detail D-4

42 SECTION D S Perspex sign panel, 6mm, applied to front face. to sign panel. and support sign form components. shadows on signpanel S7. Primary Directional Two Sided Suspended Sign Sheet 5 of 5 6 Detail 2 - Hairllne butt joint Construction Details Refer to notes 25 (minimum) Detail 3 - Hairllne butt joint FINISH All panels to be spray painted with clear antigraffi ti top coat, 30% gloss level. TBC Samples are to be provided prior to manufacture. Graphics Detail 25 Refer Sheet or related sign type drawings as required C L 90 to match panel. as required. 25 Aluminium extrusion. Colour gloss white. 25 (minimum) 80 6 Detail - S7. Typical Cap Section D-5

43 SECTION D S C S7.-S4 Cross bracing as required to structural frame. Fabricated metal edge cap along top and base of signform. similar B S7.-S3 S7.2 Primary Directional Two Sided Cantilivered Sign Sheet of 2 Construction Details Refer to notes FINISH All panels to be spray painted with clear antigraffi ti top coat, 30% gloss level. TBC Samples are to be provided prior to manufacture. B S7.-S3 similar Fabricated structural frame for signform. Subframe as required applied to each external face for LED support. similar B S7.-S3 Extruded metal edge cap at vertical sides of signform. Graphics Detail Refer Sheet or related sign type drawings Elevation Section Scale :0 Structural steel post. Connection arm to be integral with post, no visible fixing. SHS stainless steel hanging support arm (x 2) welded to signform structural frame as required. Line of LED lighting subframe as required. Minimum 25 mm from face of sign panel. LED units to be secure fixed to a track system that can be released to allow lighting units to be removed from signform for servicing. Top/base cap to be removable to allow servicing. Perspex sign panel custom moulded. Extruded metal edge cap at vertical sides of signform (minimum) as required 0 Sheet 2 25 (minimum) 6 Structural zone as required. 0 S7.-S5 Plan Section Scale :0 Apex of sign to be perpendicular to structural connection and at right angle to base building. S8.2 & S9.2 to be similar setout. D-6

44 SECTION D S Cladding line (where required) S7.2 Primary Directional Two Sided Cantilivered Sign Sheet 2 of 2 Aluminium extrusion cutout to take cantilevered support arm. Internally strengthen via angle collar as required (minimum) C L 25 SHS stainless steel cantilevered support arm (x 2) welded to signform structural frame as required. Junction of support arm and signform frame to be within signform cladding line. All exposed steelwork to be stainless steel. as required Stainless steel base plate with stainless steel countersunk fixings to base building (minimum) 6 Detail - Typical cantilevered frame Scale :2 D-7

45 SECTION D S S8. Secondary Directional - Suspended Sign Sheet of 5 Provide ventilation holes at regular intervals to allow signform to vent. Provide insect mesh to internal space to ensure insects can not enter signform. Stainless steel support post indicated, as requried to support weight of signform. Visual design intent - minimum width post to be specified as required by signform. Ensure signform is stable when live/wind loads are applied to the form. Construction Details SIDE A As per typical sections and details noted. Graphics Detail FONT All Text = Zurich BT Roman SIZE All text = 50mm cap X height COLOUR TOP VIEW SIDE B Removeable top cap to allow access to lights and internal space of signform, rebated to non-removeable section of top cap. Provide secure holding system for top cap when raised in maintenance mode. Provide lifting lugs, ensure lugs are regular, minimal and non visable to passengers. Aluminium capping and end caps = White Text & Pictograms = Black opaque vinyl Logos = As per corporate specifi cations NOTE: Refer to sheet 2 & 3 for typical elevation C Sheet 4 Graphics to be 3M external grade opaque vinyl. similar B Sheet 3 Nom 2050 Oversize Baggage Lost Items 460 Oversize Baggage Lost Items A Sheet Sheet (2000mm MIN clearance) FRONT VIEW B Sheet 3 similar Illuminated zone dashed. Typical Elevation Scale :0 Typical Elevation Scale :50 D-8

46 SECTION D S Required minimum zone from light source to sign panel. SHS structural frame indicated, minimum width required to keep signform overall width as narrow as possible. Fabricate and brace as required to provide a stiff, even frame for sign form. Sign forms must withstand wind & live loads and support sign form components. Ensure structural frame does not create shadows on signpanel. 3 3 S8. Secondary Directional - Suspended Sign Sheet 2 of 5 6 Construction Refer to notes 20 Graphics Details 25 (minimum) Refer to sheet. Radius of outside curve 62mm Minimum as required to ensure even light distribution 25 as required 25 Form metal angle bracket. Mechanical fix to primary structural frame. Countersunk screw fix extrusion cap to angle bracket, colour to match panel. Regular space support bracket as required. C L Custom fabricated heat formed perspex edge cap to vertical sides of signform. Colour to be Polar White. Internal face to be spray painted white to ensure no light emittance. 25 (minimum) 6 Perspex custom moulded sign panel, 6mm minimum as required to maintain flat and even surface across length of sign form, custom moulded. Vinyl graphic applied to front face. LED light source subframe as required to maintain even distance from sign panel. LED units to be secure fixed to a track system that can be released to allow lighting units to be removed from signform for servicing. Top cap to be removable to allow servicing. Form clear acrylic block backing support, route/sand as required to fit profile. Form metal angle bracket, permanent fix to acrylic block. Mechanical fix to primary structural frame. Regular space support bracket as required. Section A Scale :2 D-9

47 SECTION D S S8. Secondary Directional - Suspended Sign Sheet 3 of 5 Construction As noted. Graphics Detail Refer Sheet SHS structural frame indicated. Fabricate and brace as required to provide a stiff, even frame for sign form. Sign forms must withstand wind & live loads and support sign form components. Structural frame not to obstruct illumination or cause shadowing. Perspex Frost sign panel to be continuous adhesive fixed to blocking piece. Colour Polar White. Perspex to be suitable for rear illumination. Graphics to be 3M external grade opaque vinyl. LED light source subframe as required to maintain even distance from sign panel. Section B Scale :2 Sub frame at regular intervals as required. Permanent fix to continuous acrylic edge blocks and primary internal frame. Paint all solid internal surfaces white or 3M Light Enhancement Film Countersunk mechanical fix sign carrier as required at regular spacing. All exposed items to be powdercoated white. Fabricated base cap, profiled to sign form curvature. Notch edges to provide sign panel front face with a secure fixing point. Permanent adhesive fix to blocking piece. Finish- powdercoat matt white all exposed items. LED units to be secure fixed to a track system that can be released to allow lighting units to be removed from signform for servicing. Top cap to be removable to allow servicing. Position light extent to ensure no framing shadows are cast onto illuminated zone on sign faces. Clear acrylic block, continuous along sign form edge. Minimum depth required to provide framing to sign form cladding components. Permanent adhesive fix to vertical perspex faces and metal base cap. D-20

48 SECTION D S S8. Secondary Directional - Suspended Sign Sheet 4 of 5 Construction As noted. Graphics Detail Refer Sheet Provide flexible collar at structural post connections, permanent fix to top cap to seal sign form. Ventilation hole as required, insert mesh to internal space to prevent ingress of debris/ insects to sign form. Circular hollow section, stainless steel hanging support arm (x 2) welded to internal signform structural frame as required. Minimum width as required. Note: Junction of support arm and signform frame to be within signform cladding line. All exposed steelwork to be stainless steel. 25 mm Fabricated top cap profiled to sign form curvature. Notch edges to provide sign panel with a secure fixing plane. Top cap to be removeable to allow access to lighting components. Finish- powdercoat matt white all exposed items. LED light source subframe as required to maintain even distance from sign panel. To be fixed to moveable frame to allow maintenance access via top cap access hatch. Perspex Frost sign panel to be adhesive fixed to blocking piece and non-removable section of top cap. Colour Polar White. 3 3 SHS internal structural frame indicated. Fabricate and brace as required to provide a stiff, even frame for sign form. LED units to be secure fixed to a track system that can be released to allow lighting units to be removed from signform for servicing. Top cap to be removable to allow servicing. Detail 2 - Cap Edge Scale : Section C Scale :2 D-2

49 SECTION D S S8. Secondary Directional - Suspended Sign Sheet 5 of Arrow zone C L 2 Message zone arrow zone Baggage claim Exit 90 nom. Toilets 50 Pictogram zone Typical Graphic Setout Scale :5 D-22

50 SECTION D S to internal frame S8.2 Secondary Directional - Double Sided Cantilevered Sign Sheet of 2 structural frame. Construction Details Refer drawing notes. Graphics Detail Refer Graphics drawings sheet 2. COLOUR Aluminium capping and end caps = White Text & Pictograms = Black opaque vinyl Logos = As per corporate specifi cations for signform. support. NOTE Refer to sheet 2 for typical elevation Refer structural engineer s details sheet 8 similar 0 S7. Sheet 5 similar Typical Elevation D-23

51 SECTION D S Airtrain Buses & Coaches Car Park Rental Cars Public Pick Up S8.2 Secondary Directional Double Sided Cantilevered Sign Sheet 2 of 2 Graphics Detail FONT Check-in = Zurich BT Roman FFL Typical Location SIZE Large text = 70mm cap X height Subtext = 35mm cap X height COLOUR Aluminium capping and end caps = White Text & Pictograms = Black opaque vinyl Logos = As per corporate specifi cations Qantas logo = As per corporate specifi cations Check-in Airtrain Buses & Coaches Car Park Rental Cars Public Pick Up Virgin logo = As per corporate specifi cations NOTE: Refer to drawing S8.2 for typical elevation Passengers with Heavy Trolleys Please use Lifts to match airline guidelines Check-in Airtrain Buses & Coaches Car Park Rental Cars Public Pick Up Passengers with Heavy Trolleys Please use Lifts Typical Graphics D-24

52 Baggage claim BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION D S Toilets Exit 400 (to suit location) S9.2 Tertiary Directional - Cantilevered Sign Sheet of Baggage claim Toilets Exit 450 A (2000mm MIN clearance) Construction Details Refer notes. Samples are to be provided prior to manufacture. Graphics Detail FONT Typical Elevation Scale :20 Typical Location Scale :50 All Text = Zurich BT Roman SIZE All text = 40mm cap X height Pictograms = 00mm O/A height COLOUR Panel colour = White (colour tbc) Airline logos = Colour to match corporate specifi cations Fabricated metal edge cap along top and base of signform. Base Building Indicative SHS structural connection. Refer structural engineer s details. Perspex sign panel custom moulded. 0 S8. Cross bracing as required to structural frame. Extruded metal edge cap at vertical sides of signform (minimum) as required 25 (minimum) Extruded metal edge cap at vertical sides of signform. Fabricated structural frame for signform. Subframe as required applied to each external face for LED support. Line of LED lighting minimum 25 mm from face of sign panel. LED units to be secure fixed to a track system that can be released to allow lighting units to be removed from signform for servicing. Top/base cap to be removable to allow servicing. 6 Structural zone as required. FRONT VIEW - Graphics not shown for clarity Typical Elevation Scale :20 Section A Scale :20 D-25

53 SECTION D S S9.2 Tertiary Directional - Cantilevered Sign Sheet 2 of 2 Cladding line (where required) Aluminium extrusion cutout to take cantilevered support arm. Internally strengthen via angle collar as required (minimum) C L 25 SHS stainless steel cantilevered support arm (x 2) welded to signform structural frame as required. Junction of support arm and signform frame to be within signform cladding line. All exposed steelwork to be stainless steel. as required Stainless steel base plate with stainless steel countersunk fixings to base building (minimum) 6 Detail - Typical cantilevered frame Scale :2 D-26

54 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION D S S0. Facility Door Sign Sheet of 2 Construction Details 20 EQ White panel Note: wall colour and signpanel colour to have minimum 30% contrast.. Raised Braille tactile lift directory.2mm thick painted aluminium panel all edges to be rounded. Grade Braille to BCA and AS428. requirements, ball bearing domes located 8mm below letters. 2. Screen printed background applied to panel surface. Text and pictograms laser cut and then glued into laser cut shapes in panel surface. FINISH - All panels to be spray painted with clear anti-graffi ti top coat, 30% gloss level. Tactile Colour 3. Panels to be conceal adhesive fi xed to surface with VHB adhesive. Panels to be free of distortion or warping when applied to surface. All surfaces to be adhesive fi xed to be prepared to adhesive manufacturers specifi cation. 200 Authorised access only Unisex Toilet LH & Shower 75 C L Type S23 panel to be located above toilet door panels at staff toilets on Level First preferred location on wall next to door on same side as door handle Second preferred location (only if first location is not possible) on door Text and pictogram are located on same side as push plate. Use RHS or LHS template as required. 400 EQ Hearing loop Tactile colour Exclusion zone Zurich Roman Colour = black Raised Tactile text To be suitable form and height to adhere to Tactile and Braille code requirements, refer specification. All Braille is indicative only and content is to be checked and typeset by Braille supplier INSTALLATION ON GLASS 4. Back of panels fi xed to glass MUST be painted. 5. Apply optically clear double sided tape to back of panel to ensure fi xings are not visible from back. 6. Installation to comply with BCA requirements. Samples are to be provided prior to manufacture. Graphics Detail FONT All Text = Zurich BT Roman SIZE All text = 20mm cap X height Pictograms = As per layout COLOUR Panel = Dulux Natural White PCWF5/737 Text = Black Dulux Domino PGA8 Access Blue = Pantone 2945 Typical Elevation Scale :20 FRONT VIEW Hearing Loop Typical Graphics Layout Scale :2 D-27

55 SECTION D S 200 NOTE HANDING REQUIREMENT Left handed = LH Right handed = RH S0. Facility Door Sign Sheet 2 of Female Toilet Male Toilet Unisex Toilet RH Unisex Toilet LH & Shower Female Toilet Braille translation = female toilet Male Toilet Braille translation = male toilet Unisex Accessible Toilet Braille translation = Unisex accessible toilet RH Unisex Accessible Toilet & shower Braille translation = Unisex accessible toilet LH and shower Male Ambulant Toilet Female Ambulant Toilet Parents Room Male Ambulant Toilet Braille translation = Male ambulant facility Female Ambulant Toilet Braille translation = Female ambulant facility Female Ambulant Toilet Braille translation = Female ambulant facility Typical Graphics Layout Scale :5 D-28

56 SECTION D S S0.3 Glazed panel safety decal Sheet of Construction Details. Digital print on ultra clear digital substrate rear mounted to glazing t.b.c, or 2. Digital print on 3m dusted crystal digital substrate rear mounted to glazing t.b.c. Vinyl selection to suit site conditions. NOTE Sample to be tested on site prior to manufacture to ensure minimum 30% contrast when viewed against the fl oor surface or surfaces within 2m of the glazing on the opposite side (AS 428.:2009 Clause 6.6.) Typical Elevation - Glazed panel safety decal Scale :20 D-29

57 SECTION D S S2.5 Facility Supergraphic Construction Details. 6mm (min) Polar White Perspex sheet cut to fabricate supergraphic form as indicated. Rear face to be painted matte black. Mask edges to ensure no bleed, and polish edges after painting. 2. Countersunk stainless steel fi xings to panel to tiled wall with 3mm deep s/s cylindrical spacer. approx 650mm approx Fixing locations indicated for aesthetic setout. Contractor to confi rm mimimum number and size. Ensure no warping of panels. Tiled wall behind supergraphic Countersunk fixings shown yellow 700mm TBC 6mm (min) Polar White Perspex sheet cut to fabricate supergraphic form as indicated. Rear face to be painted matte black. Mask edges to ensure no bleed, and polish edges after painting. Countersunk stainless steel fixings to panel to tiled wall with 3mm deep s/s cylindrical spacer. Fixing locations indicated for aesthetic setout. Contractor to confirm mimimum number and size. Ensure no warping of panels. 50 Graphic to sit 20mm above skirting C/L C/L Typical Elevation - Toilet Supergraphics Scale :25 D-30

58 SECTION D S Provide cover flange at junction to ceiling to conceal junction. Powdercoat to match ceiling components. Colour to be matt white. To align to vertical edges of signform. S3. Gate Marker Suspended Sheet of 2 Recessed countersunk fixings, powdercoat finish to match top cap. SIDE A Graphics to align to circulation path ie out side edge SIDE B TOP VIEW Exploded view NTS NOM to ceiling (COS) NOM 500 mm NOM 430 mm S3.2 edge cap similar Gradient from opaque zone to transparent zone. See graphic setout for detail. Graphics to be 3M external grade opaque vinyl. Graphics to be applied to both sides of signform. Stainless steel CHS indicated, as required to support weight of signform. Visual design intent - minimum width post to be specified as required by signform. Length of post to be 440mm from top of signform to ceiling (COS). Internal framing as required for suspended signform. Design intent is that the internal framing is similar to cantilevered sign type S3.2. Suspension & access details similar to S9., top cap & post details. 35 SIDE B Clear illuminated zone. Design intent for frame to be minimum width possible. SIDE A Elevation - Gate Marker Scale :5 D-3

59 SECTION D S S3. Gate Marker Suspended Sheet 2 of 2 29 S3. internally illuminated Gate identification to each gate lounge. Suspended off dedicated structure suspended from exisitng beams as required Note: Ensure consistent clearance Typical Elevation - Gate Marker Scale :50 D-32

60 SECTION D S S3.2 Minor Identification Amenity Signage Sheet of 4 Recessed countersunk fixings, powderoat finish to match top cap. SIDE A SIDE B NOM 500 mm NOM 430 mm 35 Design intent for frame to be minimum width possible. NOTE Refer Sheet 4 for typical graphic layouts S Gradient from opaque zone to transparent zone. See graphic setout for detail. 35 SIDE B Clear illuminated zone. Graphics to be 3M external grade opaque vinyl. Graphics to be applied to both sides of signform. SIDE A Elevations - S3.2 Amenity Signage Scale :5 D-33

61 SECTION D S as required S3.2 Minor Identification Amenity Signage Sheet 2 of 4 Internal sleeve to provide seal at junction point. Acrylic block to be shaped to fit internal curve of custom heat rolled perspex edge cap. 3 Align edge cap + sign panel. Detail 03 - Light sealing Scale : Detail 02 - Hairline butt joint Scale : Cladding line of base building. Stainless steel cover strip to conceal structural connection junction with base building. Width to match width of metal extrusion (approx. 46mm). Refer detail 03, SD322 for detail and elevation. Circular hollow section, stainless steel support arm (x 2) welded or mechanical fix to signform structural frame as required. Weld/mechanical fix support arm to base plate. Mechanical fix concealed base plate to base building structure. Custom fabricated heat formed perspex edge cap at vertical sides of signform, with internal metal subframe to provide fixing to acrylic block. Colour Polar White Frost. Inside face to be spray painted white to ensure no light emittance. Edge cap + sign panel material to match in colour and finish. Perspex Frost sign panel custom moulded. Colour Polar White. Edge cap + sign panel material to match in colour and finish. min as required 35 Refer Detail 03 Power pack for lighting internally attached to top cap of sign. Edgelit illumination unit to fit within signform structural zone as specified. Ensure light output is similar to other illuminated signforms (S9). Refer Detail 02 Detail 0 - S3.2 Amenity Signage Scale :2 D-34

62 SECTION D S Centreline of signform connection to align with centreline of cladding junction. Refer drawing SE32 for location. S3.2 Minor Identification Amenity Signage Sheet 3 of TOP VIEW Male COVER FLANGE Cladding line of base building. S/S cover flange at structural connection. To align top and base with signform. Power supply to be concealed in CHS support. Power pack for LEDs, vent as required. Removable fabricated aluminium metal edge cap along top and base of signform. Powdercoat finish, colour gloss white (2000mm MIN Clearance) Custom fabricated heat formed perspex edge cap at vertical sides of signform. 300 Edgelit LED unit to fit within signform structural zone as specified. Ensure light output is similar to other illuminated signforms (S9). Typical Elevation Scale :20 FRONT VIEW FRONT VIEW Illumination Notes Scale :5 Double row of Tetra minimax LED units. To be tested during prototyping to confirm quantity of LEDs required. LEDs to be adhesive fixed to removeable internal framing to allow for maintenance. Fabricated structural frame for signform. Minimise to ensure maximum area of signpanel illuminated zone, with no visible framing. D-35

63 SECTION D S Graphics to be 3M external grade black opaque vinyl. Vinyl to be applied to both sides. Refer: SD325 for graphic set out. S3.2 Minor Identification Amenity Signage Sheet 4 of 4 Female Toilets - Side A Female Toilets - Side B Male Toilets - Side A Male Toilets - Side B Unisex Accessible Toilets - Side A Unisex Accessible Toilets - Side B Baby Change - Side A Baby Change - Side B Typical Graphics Layout Scale : % opacity 00% opacity 60 0 Minimum width required to evenly transition from opaque zone to illumination. To be reviewed during prototyping phase. NOTE Digital print gradient to Polar White Perspex Frost to prevent shadowing from internal structure when sign is illuminated. Design intent is that graphics should appear within a soft edge glowing zone, rather than appearing framed Illuminated face set out Scale :2 Detail - Gradient for sign face Scale :5 D-36

64 Australian Transport Security Act 2004 and Aviation Transport Security Regulation 2005 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION D S S20 Operational Signage Sheet of 4 5 mm Protective earwear required Electrical Plant.E.23 5 mm Construction Details Condition METAL SIGN PANELS APPLIED TO SOLID SURFACES Glazed panel safety strip refer S Detail Typical panel setout door signs (unless noted otherwise) Scale :0 Sign panel to be.2 mm thick natural aluminium. Finish to be spray painted white on all visible surfaces. Graphics to be screenprinted. Colours as indicated on drawing All panels to be spray painted with clear antigraffi ti top coat, 30% gloss level. Fixing Panels to be conceal adhesive fi xed to surface with VHB adhesive. Panels to be free of distortion or warping when applied to surface. All surfaces to be adhesive fi xed to be prepared to adhesive manufacturers specifi cation. WARNING Security Restricted Area Unauthorised entry prohibited Maximum penalty exceeds $5,000 Electrical Plant.E.23 Protective earwear required Mechanical Plant.E.23 Condition 2 METAL SIGN PANELS APPLIED TO GLAZED SURFACES Front panel - Sign panel to be.2 mm thick natural aluminium. Finish to be spray painted white on all visible surfaces. Graphics to be screenprinted. Colours as indicated on drawing. All panels to be spray painted with clear anti-graffi ti top coat, 30% gloss level. REAR BLANK PANEL REAR MOUNTED TO GLAZING AS A BLANK Sign panel to be 0.8 mm thick natural aluminium. Finish to be spray painted white on all visible surfaces. Ensure blank sign panel is parallel and matching in location to front panel. Condition 3 & 4 on Sheet 2 of 4 0 Elevation Fixed link entry door Condition 2 02 Elevation L fixed link double door Condition 03 Elevation L Mechanical Plant room double door Condition Typical Elevation Scale :20 D-37

65 SECTION D S Note Type - 4 location TBC. Include for rear side of these types to be finished to match front face. Signs may be post mounted. S20 Operational Signage Sheet 2 of 4 Construction Details Condition & 2 on Sheet of Condition 3 STICKER VINYL SIGN PANELS APPLIED TO GLAZED SURFACES Front panel - Sign panel to be white permanent self adhesive vinyl. Graphics to be digitally printed with overlay UV protective fi lm 3M 8520 matte overlaminate or equal to front face Colours as indicated on drawing Evacuation zone Evacuation zone Evacuation zone Evacuation zone Rear blank panel - Rear mounted to glazing as a blank. Sign panel blank to be white permanent self adhesive vinyl with overlay UV protective fi lm 3M 8520 matte overlaminate or equal to front face for protection. Ensure blank sign panel is parallel and matching in location to front panel. Special assistance meeting point No entry Stairs First aid Eyewash Graphic Layout - Condition Scale :5 D-38

66 SECTION D S S20 Operational Signage Sheet 3 of First aid First aid First aid Protective earwear required Protective eyewear required Protective footwear required Protective ear, eye & footwear required Electronic devices must be switched off No smoking Electronic devices must be switched off No smoking Protective ear, eye & footwear required Electronic devices must be switched off Graphic Layout - Condition Scale :5 D-39

67 SECTION D S S20 Operational Signage Sheet 4 of 4 No smoking Smoking permitted in this area Protective eyewear & earwear must be worn Authorised access only This terminal is monitored by closed circuit television Safety vests & protective footwear must be worn Graphic Layout - Condition Scale : WARNING WARNING Protective eyewear & earwear must be worn Safety vests & protective footwear must be worn Security Restricted Area Unauthorised entry prohibited Maximum penalty exceeds $5,000 Australian Transport Security Act 2004 and Aviation Transport Security Regulation 2005 Sterile Area - Unauthorised possession of weapons or prohibited items prohibited Maximum penalty exceeds $0,000 Unauthorised entry prohibited Maximum penalty exceeds $0,000 Australian Transport Security Act 2004 and Aviation Transport Security Regulation Electronic devices must be switched off No smoking Side Side 2 Graphic Layout - Condition 2 Scale :5 D-40

68 SECTION D S Room number as required S2 Operational Signage Sheet of FIRE INDICATOR PANEL 50 MAIN SWITCH BOARD DTB PAB Construction Details Sign panel applied to solid surface 250 HYDRANT BOOSTER PAB SIGNS -0, -02, -03 Typical Graphic Layout - 50 & 25mm Text height Scale :5 align panel to door hardware GRAPHICS TO SUIT LEFT HAND HINGE align panel to door hardware..2mm thick aluminium panel. 2 pack paint fi nish on all visible surface with screen printed graphics. Sign panel applied to glazing 2..2mm thick aluminium panel. 2 pack paint fi nish on all visible surface with screen printed graphics. 3..2mm thick aluminium panel with 2 pack painted fi nish on all visible surfaces. Rear blank panel rear mounted to glazing as blank. Typical fi xing 250 FRONT VIEW TWO LINES OF TEXT -4 GRAPHICS TO SUIT LEFT HAND HINGE FIRE HOSE REEL FIRE HYDRANT FIRE EXTINGUISHER E FIRE DOOR DO NOT OBSTRUCT -3 FIRE HOSE REEL FIRE HYDRANT FIRE EXTINGUISHER 4. Panels to be conceal adhesive fi xed to surface with double sided VHB adhesive. Panels to be free of distortion or warping when applied to surface. All surfaces adhesive fi xed to be prepared to manufacturers specifi cation. FINISH All panels to be spray painted with clear antigraffi ti top coat, 30% gloss level. TBC Samples are to be provided prior to manufacture. Graphics Detail 250 FIRE HOSE REEL FIRE HYDRANT FIRE EXTINGUISHER FONT All Text = Zurich BT Roman SIZE Text = As shown COLOUR Panel = Dulux Natural White PCWF5/737 Text = To match 3M Matte Black vinyl FRONT VIEW THREE LINES OF TEXT Type B Graphic Layouts - 5Omm Text height Scale :5 LEFT HAND HINGE Typical Elevation Scale :20 Right handed text RIGHT HAND HINGE Left handed text D-4

69 SECTION D S E E.23.E.23.E.23 S2 Operational Signage Sheet 2 of Electrical transformer room Sprinkler control room IT Communications 200 Typical Left Align Graphic Layouts Scale : Emergency Generator Room Refer to architects door schedule for room numbering and message content Room Number Sequence.E.23 Level Building Unique room number zone Zurich BT Normal 40pt 20.E E.23 Sign panel to be 0.9 mm thick natural aluminium, finish to be natural aluminium or painted white, TBC. 200 Type/graphic exclusion zone Zurich BT Normal 60pt on 62pt leading 0 3 RETAIL STORE AUTHORISED ACCESS ONLY Zurich BT Normal 50pt on 52pt leading 6 Distribution Board Type/graphic exclusion zone Type A Left Align Graphic Layouts Scale :2 Type A Right Align Graphic Layouts Scale :2 D-42

70 SECTION D S.E.23 DANGER UNAUTHORISED ACCESS PROHIBITED LIFTWELL RESCUE DOOR CLOSE AND LOCK THIS DOOR S2 Operational Signage Sheet 3 of 5 Type C Right Align Graphic Layouts Scale :5.E.23.E.23.E.23 DANGER UNAUTHORISED ACCESS PROHIBITED LIFTWELL RESCUE DOOR CLOSE AND LOCK THIS DOOR Electrical Plant Mechanical Plant Typical Elevation - Type C Scale :20 Fixed link entry door Typical Elevation Scale :20 Mechanical Plant room double door D-43

71 SECTION D S S2 Operational Signage Sheet 4 of 5.E.23.E.23 Electrical Plant Electrical Plant 275 Elec plant entry door Louvred doors Typical Elevation Scale :20 D-44

72 SECTION D S S2 Operational Signage Sheet 5 of 5.E.23.E.23.E.23.E.23 FIRE SAFETY DOOR DO NOT OBSTRUCT FIRE HOSE REEL Store room Store room 275 Ext. door at stair FHR/DB External Door External Door Typical Elevation Scale :20 Typical Elevation - Right Align Scale :20 D-45

73 Appendix Sign Location Plans Sign Schedule E

74 2 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION E APPENDIX SIGN LOCATION PLAN Level Internal Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture. up to Departure Gates L.02 S5.4 L.0 S5.3 L. S5.3 L.0 S5.4 Attention This plan is to be used for general sign locations only. All locations are to be confirmed on site prior to installation. Refer also to the - sign schedule - sign type drawings Virgin Check-In fixed to bridge L.03 S9. L.04 S9. 2 L.06 S L.09 S9. LEGEND 2 to Qantas Check-in EXISTING SIGNS Single sided sign and the direction the sign is facing Double sided sign and the direction the sign is facing L.05 S4.6 2 NEW SIGNS Single sided sign and the direction the sign is facing Check-In 2 Double sided sign and the direction the sign is facing L.07 S9. Door sign (FHR, Fire Exit, Services, General Rooms, Toilets) refer to Door Signs Schedule up to Departure Gates fixed to bulkhead Arrivals down from LIFTS STAIRS L.08 S9. (Future oversize baggage ID) 25 ESCALATOR GATE NUMBER KEY PLAN - LEVEL Arrivals from Gate 37 Site Entry PATHWAYS & Passengers Departing & Passengers Arriving E-

75 2 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION E APPENDIX SIGN LOCATION PLAN Sheet of 2 Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture. L2.0 S5.3 up from Level check-in L2.26 S5.3 down to Level baggage collection & exit Attention This plan is to be used for general sign locations only. All locations are to be confirmed on site prior to installation. Refer also to the - sign schedule - sign type drawings L2.27 S5.4 LEGEND EXISTING SIGNS Single sided sign and the direction the sign is facing vinyl glazing graphics to direct to Virgin baggage collection S2.3 S3. 2 up from Level check-in Security Check L2.03 S5.4 high level accessible level L2.05 S9. L2.02 S9. L2.04 S9. L2.06 S5.4 L2.09 S5.4 2 S0. 2 L2.07 S3.2 L2.08 S3.2 L2.0 S down to Level baggage collection & exit S0. L2.20 S L2.25 S9. L2.9 S3.2 L2.24 S9. L2.23 S9. L2.2 S5.4 L2.22 S5.4 L2.8 S3. 2 high level accessible level 2 2 Double sided sign and the direction the sign is facing NEW SIGNS Single sided sign and the direction the sign is facing Double sided sign and the direction the sign is facing Door sign (FHR, Fire Exit, Services, General Rooms, Toilets) refer to Door Signs Schedule LIFTS STAIRS ESCALATOR S4.3 S4.3 L2. S7. L2.6 S4.3 L2.7 S GATE NUMBER L2.2 REM existing sign to be removed KEY PLAN - LEVEL pax departing via gate 36 L2.3 S4.3 L2.5 S4.3 L2.4 S3. 25 PATHWAYS JOINS SHEET 2 of 2 & Passengers Departing & Passengers Arriving E-2

76 2 BRISBANE AIRPORT CORPORATION PTY LTD Wayfi nding Manual Final Issue December 202 SECTION E APPENDIX JOINS SHEET of 2 SIGN LOCATION PLAN Sheet 2 of 2 Unless otherwise noted all dimensions in millimetres. Use figured dimensions in preference to scaling. Contractor to confirm all dimensions and details on site prior to manufacture. Attention This plan is to be used for general sign locations only. All locations are to be confirmed on site prior to installation. Refer also to the - sign schedule - sign type drawings L2.5 S5.4 L2.52 S5.4 L2.77 S5.4 L2.78 S5.4 LEGEND EXISTING SIGNS Single sided sign and the direction the sign is facing 2 Double sided sign and the direction the sign is facing 32 L2.76 S4.3 L2.75 S4.3 L2.74 S3. 2 S9. L2.53 S9. S0. L2.54 S L2.55 S3.2 S0. L2.56 S2.5 L2.58 S3.2 L2.59 S3.2 L2.57 S S0. 2 NEW SIGNS Single sided sign and the direction the sign is facing Double sided sign and the direction the sign is facing Door sign (FHR, Fire Exit, Services, General Rooms, Toilets) refer to Door Signs Schedule LIFTS 2 L2.72 S3. L2.60 S3. 2 STAIRS 3 L2.73 S4.3 2 L2.7 S4.3 L2.70 S3. L2.69 S4.3 L2.67 S3. 2 L2.68 S4.3 L2.6 S4.3 L2.63 S3. L2.62 S4.3 L2.64 S3. 2 L2.66 S4.3 L2.65 S ESCALATOR GATE NUMBER KEY PLAN - LEVEL PATHWAYS & Passengers Departing & Passengers Arriving E-3

APPENDIX B SIGNAGE STANDARDS

APPENDIX B SIGNAGE STANDARDS APPENDIX B SIGNAGE STANDARDS Post-merger, The University of Toledo has two signage design specifications. The former "Black & White" signage system (described in Part 1) is being phased out and gradually

More information

Signs Regulated by this document include: Signs NOT Regulated by this document include:

Signs Regulated by this document include: Signs NOT Regulated by this document include: Volume 1 : - Overview Purpose and Scope The purpose of this volume of the is to outline general criteria for the design and/or fabrication of signage within the terminals of Boston Logan International

More information

Guide. m a k i n g l i f e e a s i e r

Guide.   m a k i n g l i f e e a s i e r Guide www.durable-signs.co.uk 2 3 Welcome to the world of information... What s in store! DURABLE have a wide range of high quality, Pictograms... modern signs to display information, prompt an action

More information

PARKING GARAGE SIGNAGE DESIGN REQUIREMENTS

PARKING GARAGE SIGNAGE DESIGN REQUIREMENTS PARKING GARAGE SIGNAGE DESIGN REQUIREMENTS 1. Basic Identity System Elements: This is the master volume of the signage system and contains its entire background, along with the basic specifications for

More information

10. Transportation Facilities.

10. Transportation Facilities. Last page revision- March 31st, 1999 TEXAS ACCESSIBILITY STANDARDS (TAS) TAS Table of Contents 10. Transportation Facilities. 10.1 General. Every station, bus stop, bus stop pad, terminal, building or

More information

Americans with Disabilities Act Accessibility Survey

Americans with Disabilities Act Accessibility Survey Americans with Disabilities Act Accessibility Survey Self-Evaluation and Transition Plan Sarpy County Impound Facility 14242 S. 156th St. Springfield, Nebraska 68159 Prepared by Sarpy County Facilities

More information

INTERIOR SIGNAGE MANUAL

INTERIOR SIGNAGE MANUAL INTERIOR SIGNAGE MANUAL ➊ Purpose ➋ Procedures ➌ ADA Requirements INTERIOR SIGNAGE MANUAL ➍ Text, Braille, Pictograms and Color ➎ Families of Interior Signage ➏ Mounting Guidelines ➐ Signage Diagrams ➊

More information

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs. PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs. 1.2 PERFORMANCE REQUIREMENTS A. Structural

More information

DIVISION 10 SPECIALTIES

DIVISION 10 SPECIALTIES DIVISION 10 SPECIALTIES A. INTERIOR SIGNAGE 1. Each room number shall be displayed with a wall mounted sign that is not less than 6 square placed 60" from its center to the finished floor and adjacent

More information

*Universal Design Audit Checklist

*Universal Design Audit Checklist *Universal Design Audit Checklist Design should adapt to people, not the other way around. AD AS furniture purveyors This Checklist is designed to complete an audit of a design in process or a facility

More information

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 101423 - PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Tunnel Signage. Section B Tunnel Signage. Tunnel Signage Introduction B.1.1

Tunnel Signage. Section B Tunnel Signage. Tunnel Signage Introduction B.1.1 Tunnel Signage B Section B Tunnel Signage B.1.1 Tunnel Signage Introduction B.2 Typical Signs & Usage B.2.1 Main Directional with Map B.2.2 Secondary Directional B.2.3 Map Only Directory B.2.4 Building

More information

New York City RS 6.1 Photoluminescent Exit Path Markings

New York City RS 6.1 Photoluminescent Exit Path Markings New York City RS 6.1 Photoluminescent Exit Path Markings 2.1.1 Door Signs Fig. 1 - Door Mounted The top of the signs shall be no higher than 18 above the finished floor. Signs shall be installed either

More information

TOWN OF DENTON SIGN DESIGN GUIDELINES

TOWN OF DENTON SIGN DESIGN GUIDELINES TOWN OF DENTON SIGN DESIGN GUIDELINES Central Commercial (CC) Zoning District Guidelines General Guidelines for All Signs in the CC District Page Applicability & Purpose 1 Signs 1 Sign Overview 2 Sign

More information

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE Blast Resistant Enhanced Curtain Wall Blast Resistant Enhanced Curtain Wall Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 10 14 23 - PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

a. Plaques with fixed panel. B. Related Sections: The following sections contain requirements that relate to this section:

a. Plaques with fixed panel. B. Related Sections: The following sections contain requirements that relate to this section: SECTION 10 14 00 SIGNAGE PART 1 - GENERAL 1.1 DESCRIPTION A. This Section includes the following types of signs required for code compliance for the shell building (excludes user or tenant occupancy signage

More information

Section 1 OBC FADS /13 Access to Parking Areas

Section 1 OBC FADS /13 Access to Parking Areas Section 1 OBC 3.8.2.2 4.3.12/13 Access to Parking Areas A barrier-free path of travel is provided from: a) the entrance to the exterior parking area b) at least one parking level where a passenger elevator

More information

Winged steel blade stanchions supporting glass panels

Winged steel blade stanchions supporting glass panels Winged steel blade stanchions supporting glass panels design elements W4 Min 1000 Winged steel blade stanchions supporting glass panels W4 design The W4 stanchions are an implementation of a toughened

More information

Northpointe Renovation EPN #1701 F/A Prroject #17027 September 8, 2017

Northpointe Renovation EPN #1701 F/A Prroject #17027 September 8, 2017 SECTION 101423.16 - ROOM-IDENTIFICATION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Open mono-stringer. design elements

Open mono-stringer. design elements Open mono-stringer design elements M2 Open mono-stringer M2 design The open tread mono-stringer is now an industry standard, due in no small part to Arden Architectural Staircases optimising this design

More information

Curtain Wall Stick System (Capped)

Curtain Wall Stick System (Capped) Curtain Wall Stick System (Capped) Stick Construction Capped Curtain Wall Reference Brand: Sapa Building System Elegance 52 ST GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

Renault Store - Technical specifications. Headline zone. Renault Brand Stores - July 2015

Renault Store - Technical specifications. Headline zone. Renault Brand Stores - July 2015 Renault Store - Technical specifications Headline zone Renault Store / Technical specifications for Headline zone / Contents 2 Contents General Introduction 4 Colours & materials 5 Layout principles 6

More information

Series 5550/5551 and Series 5630/5631 Acoustic Glass Walling

Series 5550/5551 and Series 5630/5631 Acoustic Glass Walling Series 5550/5551 and Series 5630/5631 Acoustic Glass Walling Product Detail Sheets General Description Options Key Market Segments Features and Benefits Product Specification Sheet Product Elevation and

More information

Site Accessibility Survey & Transition Plan

Site Accessibility Survey & Transition Plan Site Accessibility Survey & Transition Plan Organization Name: Person Completing Form: Site Name: Site Address: Date Completed: Instructions: 1. Please circle the appropriate response for each question.

More information

Technical Specifications

Technical Specifications Technical Drawing not currently available for this sign type P-CS-01 Campus Signature A Prominent external location to be negotiated with and approved by Property Unit P-CM-01 Campus Map Type A Wall Mounted

More information

The Catholic University of America Cardinal Station Washington, DC INTERIOR SIGNAGE GUIDELINES. January 21, 2009 (Revised)

The Catholic University of America Cardinal Station Washington, DC INTERIOR SIGNAGE GUIDELINES. January 21, 2009 (Revised) The Catholic University of America Cardinal Station Washington, DC 20064 January 21, 2009 (Revised) OBJECTIVES The Interior Signage Guidelines for The Catholic University of America are intended to establish

More information

Disability Standards for Accessible Public Transport 2002

Disability Standards for Accessible Public Transport 2002 Disability Standards for Accessible Public Transport 2002 as amended made under subsection 31 (1) of the Disability Discrimination Act 1992 This compilation was prepared on 11 May 2005 taking into account

More information

Fully framed glass panels

Fully framed glass panels Fully framed glass panels design elements G1 Fully framed glass panels G1 design The G1 is a fully framed balustrade solution suiting a refined and deliberate architectural style. Rather than minimising

More information

Clad truss stair. design elements

Clad truss stair. design elements Clad truss stair design elements T2 Total covered rise Total structural rise Top tread width Total going Tread going (typically 250-280) Clad truss stair T2 design Truss construction methods have natural

More information

Section PANEL SIGNAGE

Section PANEL SIGNAGE Section 10 14 23 PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including FDOT DIVISION I GENERAL REQUIREMENTS & COVENANTS Specification Sections,

More information

3M Industrial & Transportation Business. Design Guide for Sign Assembly. Bonding. commercial signage market

3M Industrial & Transportation Business. Design Guide for Sign Assembly. Bonding. commercial signage market 3M Industrial & Transportation Business Design Guide for Sign Assembly Bonding for the Solutions commercial signage market Using traditional fabrication techniques such as rivets, screws and spotwelding

More information

The Renault PRO+ zone

The Renault PRO+ zone Renault Store - Technical specifications The Renault PRO+ zone Renault Store / Technical specifications for Renault PRO+ zone / Contents 2 Contents General Introduction 4 Colours & materials 5 Renault

More information

Unleash Your Creative Potential with Slim-Panel Signage System

Unleash Your Creative Potential with Slim-Panel Signage System Macer Interior Modular Product olutions Unleash Your Creative Potential with lim-panel ignage ystem Macer Interior provides the freedom to unleash your creative ideas and achieve a precise look within

More information

Michigan State University Construction Standards PAGE

Michigan State University Construction Standards PAGE Construction Standards PAGE 101400-1 SECTION 101400 - PART 1 - GENERAL 1.1 M.S.U. ISSUES A. It is the objective of the University to provide all necessary signage to provide information for occupants,

More information

TENDER BASTION STREET BRIDGE RENEWAL AND SEISMIC RETROFIT ADDENDUM 1

TENDER BASTION STREET BRIDGE RENEWAL AND SEISMIC RETROFIT ADDENDUM 1 TENDER 2334-2019 BASTION STREET BRIDGE RENEWAL AND SEISMIC RETROFIT ADDENDUM 1 This addendum shall be read in conjunction with and considered as an integral part of the Tender Contract 2334-2019. Revisions

More information

3.10 ROW Overlay District

3.10 ROW Overlay District 3.10 A. Purpose The purpose of this Overlay District is to regulate items which could be placed or constructed within the Rrights-of-way lying wholly or partially within the jurisdictional area of the

More information

University of Illinois at Chicago Exterior Signage Standard

University of Illinois at Chicago Exterior Signage Standard University of Illinois at Chicago Exterior Signage Standard Exterior Signage Production Requesting Process If requestor is a(n): Individual Person (Outside of a PPCON/CPPM Project) Individual requestors

More information

CONSTRUCTION SPECIFICATION

CONSTRUCTION SPECIFICATION CAPRICORN MUNICIPAL DEVELOPMENT GUIDELINES SIGNPOSTING C262 CONSTRUCTION SPECIFICATION TABLE OF CONTENTS CLAUSE CONTENTS PAGE GENERAL... 3 C262.01 SCOPE... 3 C262.02 REFERENCE DOCUMENTS... 3 C262.03 PROVISION

More information

1. Refer to SECTION SIGNS and reolace entire document with aftached new soecification. 5. Refer to Electrical Drawing E3.1

1. Refer to SECTION SIGNS and reolace entire document with aftached new soecification. 5. Refer to Electrical Drawing E3.1 OTC REALIGNMENT - 8TH FLOOR ADDENDUM THREE June 25, 205 DRAWING CHANGES:. Refer to Mechanical Drawing M3. a. Revised: Fan Powered Terminal Unit Schedule. b. Revised: Variable Air Terminal Unit Schedule.

More information

SECTION DIRECTORIES

SECTION DIRECTORIES PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 13 00 DIRECTORIES SPEC WRITER NOTES: 1. Delete // // if not applicable to project. Also delete any other item or paragraph not applicable in the section and

More information

SITE ACCESSIBILITY AND PARKING

SITE ACCESSIBILITY AND PARKING SITE ACCESSIBILITY AND PARKING The purpose of this handout is to clarify the requirements of site accessibility under the 2013 California Building Codes, Specifically, Section 11B. Each lot or parking

More information

Responsibility Check List Sheet Item Description Responsibility Additional

Responsibility Check List Sheet Item Description Responsibility Additional Responsibility Check List Sheet Item Description Responsibility Additional A B C Sketch Brief Layout for the position of the mezzanine. Advise whether requirement to remove intermediate columns to provide

More information

SECTION INTERIOR UNFRAMED SIGNS PHOTOPOLYMER BONDED TO ACRYLIC (InTouch )

SECTION INTERIOR UNFRAMED SIGNS PHOTOPOLYMER BONDED TO ACRYLIC (InTouch ) GUIDE SPECIFICATION Corporate Office: ASI Signage Innovations 8181 Jetstar Drive, Suite 100 Irving, Texas 75063 (214) 352-9140 voice (214) 352-9741 facsimile (800) ASI-SPEC [274-7732] www.asisignage.com

More information

Vertical Transportation Planning Retail/Mixed-Use

Vertical Transportation Planning Retail/Mixed-Use Fortune Consultants LTD Elevator Consulting Vertical Transportation Planning Retail/Mixed-Use This paper is to provide design guidance for the initial planning of vertical transportation in either a standalone

More information

T1. Steps and stairs general

T1. Steps and stairs general T1. Steps and stairs general T1. Steps and stairs general Figure T1.1 A typical station footbridge staircase 240 Code of Practice Version 02 September 2010 T1. European standards and national standards

More information

2009 IBC Section 1024 Approved Luminous Egress Path Markings

2009 IBC Section 1024 Approved Luminous Egress Path Markings 2009 IBC Section 1024 Approved Luminous Egress Path Markings Where Required Buildings of Groups A (Assembly), B (Business), E (Education), I (Institutional), M (Mercantile) and R-1 (Residential transient

More information

Through-glass patch fittings supporting cantilevered glass panels

Through-glass patch fittings supporting cantilevered glass panels Through-glass patch fittings supporting cantilevered glass panels design elements F8 190 (rise) 38 domestic grade patch fittings used. 190 (rise) 38 domestic grade patch fittings used. Through-glass patch

More information

SOMNIUM SIGNS PROMOTING YOUR BUSINESS

SOMNIUM SIGNS PROMOTING YOUR BUSINESS SOMNIUM SIGNS PROMOTING YOUR BUSINESS WHO, WHAT, WHY... At Somnium Signs we offer an extensive selection of internal and external signage. We also specialise in window graphics, way finding, poster cases,

More information

Signs Regulated by this document include: Signs NOT Regulated by this document include:

Signs Regulated by this document include: Signs NOT Regulated by this document include: Purpose and Scope The purpose of this volume of the is to outline general criteria for the design and/or fabrication of signage within the airport services buildings of Boston-Logan International Airport

More information

CITY OF DANA POINT SITE ACCESSIBILITY AND PARKING B103 SITE INTRODUCTION

CITY OF DANA POINT SITE ACCESSIBILITY AND PARKING B103 SITE INTRODUCTION INTRODUCTION CITY OF DANA POINT COMMUNITY DEVELOPMENT, BUILDING AND SAFETY 33282 Golden Lantern, Suite 209 Dana Point, CA 92629 949 248-3594 www.danapoint.org SITE ACCESSIBILITY AND PARKING B103 SITE 2013

More information

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION Sheet 1 of 7 NOTE: This special provision is generally written in the imperative mood. The subject, the

More information

NEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1

NEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1 MTA RR APPARATUS NEW ILLUMINATED LED SIGNAGE LIGHTWEIGHT REMOVABLE ALUMINUM PANEL FENCE 88 NORTH AVE CDR JOB NO. 60 NORTH AVE NORTH AVE CURRENT VIEW OF 88 NORTH AVENUE PROPOSED FACADE AT 88 NORTH AVENUE

More information

2007 Title 24 Accessibility Code Updates and ADA Issues

2007 Title 24 Accessibility Code Updates and ADA Issues 2007 Title 24 Accessibility Code Updates and ADA Issues C.A.S.H. Workshop June 2007 Introduction Update on ADA Certification of the California Building Code Overview of significant changes to accessibility

More information

SECTION 716 SIGN MATERIALS SCOPE

SECTION 716 SIGN MATERIALS SCOPE 716 716.01.01 MATERIALS COVERED SECTION 716 SIGN MATERIALS SCOPE A. This specification covers the kind and quality of materials used in the construction and fabrication of traffic control devices used

More information

DALLAS-FORT WORTH INTERNATIONAL AIRPORT

DALLAS-FORT WORTH INTERNATIONAL AIRPORT DALLAS-FORT WORTH INTERNATIONAL AIRPORT ADDENDUM NO. 2 TO THE REQUEST FOR BIDS Contract No. 9500445 Restroom Rehabilitation at Terminal B (Phase 3 & 4) December 20, 2010 THE REQUEST FOR BIDS (RFB) FOR

More information

Uniform Sign Plan (USP) Searstone 08-USP-009

Uniform Sign Plan (USP) Searstone 08-USP-009 Uniform Sign Plan (USP) Searstone 08-USP-009 A sign permit application must be submitted and a permit issued prior to installation of any sign, unless the LDO states that it is exempt from regulations.

More information

Your single source mass transit solution.

Your single source mass transit solution. Your single source mass transit solution. The strong foundation built under this structure means you can be confident that we have the competency and economic background necessary for supporting all our

More information

Title: The Methodist Church, 86 Market Street Chapel-en-le-Frith, Derbyshire SK23 0HZ

Title: The Methodist Church, 86 Market Street Chapel-en-le-Frith, Derbyshire SK23 0HZ Access Audit Report Title: The Methodist Church, 86 Market Street Chapel-en-le-Frith, Derbyshire SK23 0HZ Date of Audit: Thursday 6 th June 2013. 10.45-12.45am Auditors: Dave Bennett, Alan Jackson This

More information

Construction Standards PAGE

Construction Standards PAGE Construction Standards PAGE 102810-1 SECTION 102810 - PART 1 - GENERAL 1.1 M.S.U. ISSUES A. Mirrors will normally be provided at all lavatory locations. Provide full-length mirror on adjacent wall for

More information

Sign No. 9 Pedestrian - Major Directional

Sign No. 9 Pedestrian - Major Directional Sheet Number Sheet List Sheet Name 01 title and drawing list 02 typography, colours and pictograms 03 sign design - overview 04 sign design - graphic design details 05 sign construction - section 06 sign

More information

Introduction: Signage

Introduction: Signage Introduction: Signage Version /22 L3 Page.6. The Logo Library contains a special section with logos for signage applications. These files are in the EPS (Encapsulated PostScript) format and should be used

More information

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS Acousti-Clear Automatic Seal Paired Panel 10 22 26 (10650) Operable Partitions SPECIFICATION - SECTION 10 22 26 (10650) OPERABLE PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general

More information

SMART Access Assessment

SMART Access Assessment SMART Access Assessment Company Name Premises Date Of Audit Auditor Trinity College Dublin Santry Book Repository - Zone 15 21 August 2008 Wesley lan Priority 1 Priority 2 Priority 3 Adjustments required

More information

Sliding Door Systems

Sliding Door Systems Sliding Door Systems Standard Sliding System Reference Brand: Sapa Building System Plaisance 24 GENERAL DESCRIPTION Sliding window and door system with a frame depth of 50 mm (two rail version), 97mm (three

More information

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes

More information

Semi-framed steel and glass panel balustrade

Semi-framed steel and glass panel balustrade Semi-framed steel and glass panel balustrade design elements G2 Semi-framed steel and glass panel balustrade G2 design The G2 semi-frameless balustrade design is one of the most elegant balustrade formats

More information

CONCEPT DESIGN BCA REPORT

CONCEPT DESIGN BCA REPORT CONCEPT DESIGN BCA REPORT CONCEPT DESIGN DOCUMENTATION PROPOSED ZUCCOLI PRIMARY SCHOOL 13/4/17 CONCEPT DESIGN Project: Zuccoli Primary School Location: Centre Road Zuccoli NT 0382 Prepared For: MKE Architects

More information

Soundmaster & Modernfold TECHNICAL DATA

Soundmaster & Modernfold TECHNICAL DATA This specification along with product information and model details can be downloaded from www.modernfold.com SPECIFICATION - SECTION 08 35 13 ACCORDION FOLDING DOORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

More information

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM SECTION 07400 TERRA COTTA CLAY TILE RAINSCREEN SYSTEM PART 1 GENERAL 1.01 WORK INCLUDED A. The terra cotta clay tile elements and aluminum support system shall be manufactured by NBK Keramik GmbH as represented

More information

Design Guidelines October 2016: Issue 3. Section 15 Lifts.

Design Guidelines October 2016: Issue 3. Section 15 Lifts. Design Guidelines Section 15 Lifts. www.canterbury.ac.nz/learningresources Standards in the Design Guidelines Suite Design Standard Guidelines Index: 01 General 02 Architecture 03 Audio Visual 04 Civil

More information

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section. SECTION 10 5300 ALUMINUM WALKWAY COVERS Part 1 General 1.01 Related Documents A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.02 References A. International

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING SECTION 09665 RESILIENT SHEET FLOORING PART 1 - GENERAL 1.1 DESCRIPTION A. This Section specifies the installation of sheet flooring with backing and integral cove base. 1.2 RELATED WORK A. Color and pattern:

More information

Feature Truss. design elements

Feature Truss. design elements Feature Truss design elements T1 Floor to floor structural rise Floor to floor covered rise Feature Truss T1 design Eliminating the traditional distinctions between stringer, handrail and stanchion, the

More information

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA Paired panel system Acoustically rated glass wall system Automatic seal system Hinged together in groups of two, facilitating quick, easy setup Each panel is supported by a single carrier Ideal for straight-line

More information

Steel SHS stanchions supporting glass panel infill

Steel SHS stanchions supporting glass panel infill Steel SHS stanchions supporting glass panel infill design elements C8 Min 1000 Steel SHS stanchions supporting glass panel infill C8 design Stainless steel SHS stanchions support glass infill panels on

More information

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling SPECIFICATION For the Supply and Installation of BRITAL UN-4-76 Four Sided Unitized Structurally Glazed Curtain Walling Issue date Revision Comment 07/05/09 R0 Draft 11/05/09 R1 Approved for Issue R1 Amended

More information

General Requirements for Access

General Requirements for Access General Requirements for Access AS1428 Series 2009 Edition COPYRIGHT GRIMBOS BUILDING SURVEYORS ACCESSIBLE TOILET General Requirements for Access (AS1428 Series 2009 Edition) > ACCESSIBLE TOILET MINIMUM

More information

quality. precision. creativity. flexibility by signbox

quality. precision. creativity. flexibility by signbox Signkit, a complete system of precision engineered components for the display of signs and media. Designed with the versatility to provide simple but effective signs. The fully integrated sign system.

More information

SIGNAGE. Raymond Design Guidelines Signs

SIGNAGE. Raymond Design Guidelines Signs SIGNAGE BACKGROUND INTRODUCTION Signs play a central role in providing much-needed information and setting the tone for Raymond s commercial district. They inform motorists and pedestrians and have a direct

More information

Symonite Decorative Panelling

Symonite Decorative Panelling Symonite Decorative Panelling WHY SYMONITE? Symonite is the only Australian manufactured aluminium composite panel. An Australian owned company whose continuous composite panel research and development

More information

INTERIOR SIGNAGE

INTERIOR SIGNAGE 101400 INTERIOR SIGNAGE PART 1: GENERAL 1.01 The Cornell University Interior Sign Standard has been developed to address the need for functional, flexible, and serviceable interior signs. The intent of

More information

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1 16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

SECTION SERVICE AND TELLER WINDOW UNITS

SECTION SERVICE AND TELLER WINDOW UNITS SECTION 08 56 59 SERVICE AND TELLER WINDOW UNITS SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. See Pharmacy Service Window and Package

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

A. WCMA A Safety of Corded Window Covering Products; Window Covering Manufacturers Association; (ANSI/WCMA A101.1)

A. WCMA A Safety of Corded Window Covering Products; Window Covering Manufacturers Association; (ANSI/WCMA A101.1) SECTION 12 21 14 VERTICAL LOUVER BLINDS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Vertical slat louver blinds and operating hardware. 1.2 REFERENCE STANDARDS A. WCMA A100.1 - Safety of Corded Window Covering

More information

Plan Check No. A. ELEVATORS

Plan Check No. A. ELEVATORS Elevators, Egress and Areas of Refuge, Platform Lifts Plan Check No. A. ELEVATORS NOTE: In buildings two or more stories in height, served by an elevator, or a building served by an elevator required by

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.

More information

Extruded aluminum profile up to 3m long anodized or powder coated in aviation yellow.

Extruded aluminum profile up to 3m long anodized or powder coated in aviation yellow. Poshdecor Taxiway Guidance Signs Looking for operational signs! our difference is your advantage! Introduction Taxiway Guidance Signs are manufactured at our workshop in Mumbai located at stone's throw

More information

DESIGN GUIDELINES FOR ON-PREMISE SIGNS AND AWNINGS (Adopted June 17, 2003)

DESIGN GUIDELINES FOR ON-PREMISE SIGNS AND AWNINGS (Adopted June 17, 2003) DESIGN GUIDELINES FOR ON-PREMISE SIGNS AND AWNINGS (Adopted June 17, 2003) Introduction to the Guidelines: The Design Guidelines for On-Premise Signs and Awnings are established to allow for effective

More information

Renault Store - Technical specifications. Initiale Paris area. Renault Brand Stores - July 2015

Renault Store - Technical specifications. Initiale Paris area. Renault Brand Stores - July 2015 Renault Store - Technical specifications Initiale Paris area Renault Store / Technical specifications for Initiale Paris zone / Contents 2 General Introduction 4 Colours & materials 5 Layout principles

More information

Surface Mounted Tactile Paving

Surface Mounted Tactile Paving Product Description Our surface mounted tactile paving slabs incorporate raised profiles to warn people that they are approaching a change in elevation such as railway platforms, pedestrian crossings,

More information

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION Sheet 1 of 5 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION Delete SECTION 812 and replace with the following: SECTION 812 PERMANENT SIGNING 812.1 DESCRIPTION

More information

Unitised Curtain Wall Beaded

Unitised Curtain Wall Beaded Unitised Curtain Wall Beaded Glazed Frame Unitised Curtain Wall Reference Brand: Sapa Building System Elegance 72 GF GENERAL DESCRIPTION Unitised curtain wall system using glazing beads for glass retention.

More information

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

INDUSTRIAL GUARDRAIL SYSTEMS

INDUSTRIAL GUARDRAIL SYSTEMS INDUSTRIAL GUARDRAIL SYSTEMS STRONGEST GUARDRAIL ON THE MARKET MANUFACTURED IN THE U.S.A. BEST PRICES MOST VARIETIES HEAVY DUTY ONE-LINE OR TWO-LINE Posts: 4 Sched 80 pipe Rail: 6 Sched 40 pipe Sleeved

More information

In-Ground Removable Bollard PRODUCT MANUAL. Installation Operation Maintenance

In-Ground Removable Bollard PRODUCT MANUAL. Installation Operation Maintenance PRODUCT MANUAL In-Ground Removable Bollard Installation Operation Maintenance Access Technologies (WA) Pty Ltd PO Box 1060 GWELUP DC WA 6018 Email: ask-us@accesstechnologies.com.au Phone: +61-(0)8-6305

More information

SECTION METAL STAIRS

SECTION METAL STAIRS SECTION 05510 METAL STAIRS PART 1 GENERAL 1.01 SECTION INCLUDES A. Stairs with concrete treads. B. Stairs with metal treads. C. Structural steel stair framing and supports. D. Handrails and guards. 1.02

More information

Appendix 3 Treads. design elements

Appendix 3 Treads. design elements Appendix 3 s design elements A3 42 rise 165 Appendix 3 s A3 design This is a reference guide to standard treads used in the Arden Elements range. Many custom staircases will demand their own unique tread

More information

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints) SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF Two Sided Structurally Glazed Curtain Walling (Horizontal Structural joints) Issue date Revision Comment R0 Draft 05/05/09 R1 Approved

More information