Simpson Dura-Vent Engineered Excellence

Size: px
Start display at page:

Download "Simpson Dura-Vent Engineered Excellence"

Transcription

1

2 DuraLiner Simpson Dura-Vent Engineered Excellence pplications Materials and onstruction DuraLiner DuraLiner ensures safe and efficient venting of heating appliances, while protecting the masonry chimney from the damaging effects of flue product condensation. It is the only factory-insulated product with zero/zero clearance for high heat wood-burning appliances. No need to uncoil flex, insulate a majority of the pipe, or protect the insulation when installing. smooth inner means less creosote buildup. Installers reduce labor time by 50% or more with DuraLiner. No time wasted wrapping insulation around liner for UL1777 approval. No warping or ovalizing. No investment needed in special equipment or tools or cutting pieces on the job site. learances Diameters Listings Limited-Lifetime Warranty No spacers needed to maintain clearance in tight offsets or dampers. pproved for use in both the US and anada. warranty Limited Lifetime guarantee 86

3 DuraLiner himney Relining Typical Installations Installation Key or 45 SS Elbow 16 Round Tee with Round ranch 23 Transition nchor Plate 17 DuraTech or DuraPlus himney 24 Two-Ply Insulation Sleeve 18 DuraLiner - rigid length 25 Insulation lamp 19 DuraLiner - flexible length 26 DuraLiner ppliance onnector 20 Masonry Thimble w/ Slip onnector 27 DVL or Duralack Stovepipe 21 Slip onnector and Hanger your installation. proper support and bracing. Follow local building codes and have your venting system inspected. 19 Wood Fireplace Wood Stove With Stovepipe Extend--ap Kit 17 DuraLiner Rigid Length Insulation lamp Two-Ply Insulation Sleeve (Required only where the flex enters the clay liner of the chimney.) Wood Fireplace Transition To himney DuraLiner Flexible Length 45 Elbow or Stove dapter 87 Simpson Dura-Vent

4 himney Relining DuraLiner Planning Your Installation 1 Verify the venting requirements of the appliance used. hoose the liner system appropriate for the appliance and installation. 2 Refer to the Typical Installations for the needed parts for installation. 3 penetrates into the masonry chimney. 4 Determine the length of liner needed. When using DuraLiner, subtract overlap per joint Make sure the top of the masonry chimney has a leveled surface to insure a proper fit for the Extend--ap and provide a secure, leak-proof installation. If a free-standing appliance is used, select the vent or stovepipe pieces to connect from the appliance to For Installations using a Transition nchor Plate, refer to the DuraTech, DuraPlus or DuraPlus HT catalogs or installation instructions for proper parts and installation. including clearance to combustibles. ontact the local building inspector for permit requirements. How Size and Height ffect Stove Performance The following design recommendations are intended only as a general guideline to assist in the design and selection of liner components for your installation. Read and follow the DuraLiner installation instructions before installation begins. efore relining a chimney, it should be cleaned and inspected to verify the integrity of the mortar and masonry. This is an important fire safety issue that may have an influence on how the liner is installed. DuraLiner is approved for 0 clearance between the liner and masonry and 0 clearance between the masonry and combustibles. DuraLiner is used for wood-burning appliances when zero clearance or oval pipe is needed. Refer to the appliance manufacturer for installation requirements affecting venting. Keep the vent path as straight as possible for best performance. Restore Deteriorating himneys with DuraLiner When a masonry chimney is damaged or has fallen down, it can be replaced with a safe, factory-built chimney. DuraLiner, when used with a Transition nchor Plate and in combination with DuraTech, DuraPlus, or DuraPlus HT himneys, replaces the damaged masonry chimney with a safe, efficient, and economical chimney that is UL Listed (DuraPlus HT is listed for use in anada). See Typical Installations for details Simpson Dura-Vent 88

5 DuraLiner himney Relining 30º Stove onnector onnects stove outlets to round or oval DuraLiner pipe at a 30 angle. SIZE ONNETION STOK # 6 Round - Round Round - Oval 4681-RO Oval - Oval 4681-O Round-Round ¼ 8 Round - Oval 4881-RO Oval - Oval 4881-O Flat Stove onnector onnects stove outlets to round or oval DuraLiner pipe. Oval stove connector is sized to easily convert round stove outlets to oval DuraLiner pipe. SIZE STOK # 2 6 ROUND OVL 4680-O -- 8 ROUND OVL 4880-O -- 30º and 45º Stainless Steel Elbows 30 Use as a stove connector to DuraLiner. Features built-in fittings for easy connection to DuraLiner. 30 and 45 elbows are single-wall. SIZE NGLE STOK # Simpson Dura-Vent

6 himney Relining DuraLiner Round Tee With Round ranch With ap Provides connection between Masonry Wall Thimble or stove connector pipe to round DuraLiner. SIZE STOK # Oval Tee With Round ranch With ap Provides connection between Masonry Wall Thimble or stove connector pipe to oval DuraLiner. Single-wall. May require additional insulation. Refer to DuraLiner installation instructions. SIZE STOK # D O D Spacer Use to maintain a 1 clearance with flex sections of DuraLiner. 3¼ SIZE STOK # 6 OVL 4668-O 8 OVL 4868-O djustable Sleeve from to 12 8½ to 12 SIZE STOK # Simpson Dura-Vent 90

7 DuraLiner himney Relining Masonry Thimble with Slip onnector 7¼ Penetrates masonry chimney to allow connection of Duralack pipe or DVL black pipe to DuraLiner. SIZE STOK # Wall Pass Through onnects to a DuraLiner tee to bring DuraLiner through a masonry chimney and a combustible wall. llows the connection of Duralack pipe or when used with the appropriate adapter. DVL black pipe will connect directly to the Wall Pass Through. SIZE STOK # Round-To-Round Heavy Duty Flex Pipe construction. Use through damper and smoke shelf area. Features built-in fittings, which eliminates field cutting and fitting. Use with DuraLiner Two-Ply Insulation Sleeve for zero clearance applications where flex extends into clay liner. SIZE STOK # 6 6DL-36OF DL-60OF DL-36OF DL-60OF Simpson Dura-Vent

8 himney Relining DuraLiner Round-To-Round Flex Pipe Use through damper and smoke shelf area. uilt from 304 stainless steel. Use with DuraLiner Two-Ply Insulation Sleeve for zero clearance applications where flex extends into clay liner. SIZE STOK # F F F F Oval-To-Oval Heavy Duty Flex Pipe Oval-to-Oval Flex pipe built from.016", 304 stainless steel, 4-ply construction. Use through damper and smoke shelf area. Features built-in fittings, which eliminates field cutting and fitting. Use with DuraLiner Two-Ply Insulation Sleeve for zero clearance applications where flex extends into clay liner. 4¾ SIZE STOK # 6 6DL-36OF DL-60OF DL-36OF DL-60OF 10 3 Oval-To-Oval Flex Pipe Use through damper and smoke shelf area. uilt from 304 stainless steel. Use with DuraLiner Two-Ply Insulation Sleeve for zero clearance applications where flex extends into clay liner. 4¾ SIZE STOK # OF OF OF OF Simpson Dura-Vent 92

9 DuraLiner himney Relining Oval-To-Round Heavy Duty Flex Pipe Oval-to-Round flex pipe built from.016", 304 stainless steel, 4-ply construction. Use through damper and smoke shelf area. Use to connect from oval stove outlet to round DuraLiner. Use with DuraLiner Two-Ply insulation Sleeve for zero clearance applications where flex extends into clay liner. SIZE STOK # 6 6DL-36ORF DL-60ORF DL-36ORF DL-60ORF ¾ Oval-To-Round Flex Pipe Use through damper and smoke shelf area. Use to connect from oval stove outlet to round DuraLiner. uilt from 304 stainless steel. Use with DuraLiner Two-Ply insulation Sleeve for zero clearance applications where flex extends into clay liner. SIZE STOK # OR OR OR OR ¾ Round-To-Oval Flex Pipe Use as a stove connector from a round stove outlet to oval DuraLiner. uilt from 304 stainless steel. Use with DuraLiner Two-Ply insulation Sleeve for zero clearance applications where flex extends into clay liner. 4¾ SIZE STOK # RO RO Simpson Dura-Vent

10 himney Relining DuraLiner Round Rigid Pipe vailable in 6 and 8 diameters in 12, 24, 36, and 48 lengths. Factory insulated. uilt-in, pre-drilled fittings for riveting joints. UL Listed for zero clearance between masonry and combustibles, plus zero clearance between liner and masonry. 304 stainless steel inner and aluminized steel outer. SIZE STOK # Oval Rigid Pipe Factory insulated, Oval Rigid Pipe is available in 6 and 8 diameters; 12, 24, 36, and 48 lengths. Insulated. uilt-in pre drilled fittings for riveting joints. UL Listed for zero clearance between masonry and combustibles, plus zero clearance between liner and masonry. 304 stainless steel inner and aluminized steel outer. 4¾ SIZE STOK # OP OP OP OP OP OP OP OP Extend--ap Kit ap Storm ollar Support lamp ase Plate Terminates DuraLiner at the top of the masonry chimney. Kit includes ase Plate, Support lamp, Storm ollar, and ap (with spark arrestor). Pipe not included. SIZE STOK # O O O O Simpson Dura-Vent 94

11 DuraLiner himney Relining Slip onnector and Hanger Slip onnector Hanger Use with Transition nchor Plate to transition from DuraLiner to DuraTech, DuraPlus, or DuraPlus HT chimney. 14 Slip onnector. SIZE STOK # Transition nchor Plate Use with Slip onnector and Hanger in chimney restoration to connect DuraLiner pipe to DuraTech, DuraPlus, or DuraPlus HT himney. DURPLUS HT D himney Section Slip onnector Transition nchor Plate DuraLiner System SIZE STOK # D D D DURTEH SIZE STOK # D D D Simpson Dura-Vent

12 himney Relining DuraLiner Two-Ply Insulation Sleeve Use with DuraLiner round and oval flex lengths above the first clay flue tile to meet UL 1777 standards. (Use to meet zero-clearance requirements between the DuraLiner length and the inside of the chimney, and, the outside combustibles above the first clay flue tile.) Features high-temperature blanket insulation with an abrasion resistant fabric cover. Use with Insulation lamp (below). SIZE STOK # Z Z Insulation lamp Fits round or oval up to 8. Universal No bolt or steel protrusions minimizes snagging. Toggle action provides fast, secure fit. SIZE STOK # Universal Simpson Dura-Vent 96

DuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640.

DuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640. DuraLiner Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640. Specifications pplications DuraLiner is a high-temperature, insulated double-wall masonry relining system for use with

More information

Simpson Dura-Vent Engineered Excellence

Simpson Dura-Vent Engineered Excellence DuraPlus Simpson Dura-Vent Engineered Excellence pplications DuraPlus himney is a triple-wall, all-fuel chimney for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges, water heaters, or

More information

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT. DuraPlus ll-fuel, triple-wall chimney system. UL 103 HT. Specifications pplications DuraPlus himney is a triple-wall, all-fuel chimney for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges,

More information

DVL. DuraBlack. Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC S641.

DVL. DuraBlack. Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC S641. Duralack Single-wall interior stovepipe for connecting woodstoves to chimney. Specifications DVL pplications

More information

Dur aflex stainless steel

Dur aflex stainless steel Dur aflex stainless steel Simpson Dura-Vent Engineered Excellence DuraFlex SW DuraFlex SW is a smooth inner-wall, flexible stainless steel chimney liner. The smooth inner wall provides for no output reduction

More information

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. DuraFlex Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. Specifications DuraFlex Pro Applications DuraFlex Pro ultra flexible relining for masonry chimney. Use with gas, wood

More information

APPLICATION AND LISTING

APPLICATION AND LISTING DURALINER (SDL) 6"-8" DIAMETER (ROUND & OVAL) INSTALLATION INSTRUCTIONS MH14420 CMH1329 THESE INSTALLATION AND OPERATION INSTRUCTIONS COVER DURALINER MASONRY RELINING SYSTEM A MAJOR CAUSE OF CHIMNEY RELATED

More information

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. DuraFlex Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. Specifications DuraFlex SW Applications DuraFlex SW smooth wall flexible relining for masonry chimney. Use with gas,

More information

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval.

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5 Round 6, 8 Round and Oval. Installation Instructions High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval DuraLiner A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED

More information

Vent Termination Chart. horizontal Termination Kit A. horizontal Termination Kit C. Chimney Liner Termination Kit. DirectVent Pro Direct Vent

Vent Termination Chart. horizontal Termination Kit A. horizontal Termination Kit C. Chimney Liner Termination Kit. DirectVent Pro Direct Vent irectvent Pro irect Vent Vent Termination hart H X 12 Minimum height Roof Pitch Feet Meters Flat to 7/12 1 0.30 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2 0.61 Over 9/12 to 10/12 2.5 0.76 Over 10/12

More information

DirectVent Pro. Simpson Dura-Vent Engineered Excellence

DirectVent Pro. Simpson Dura-Vent Engineered Excellence irectvent Pro Simpson ura-vent Engineered Excellence pplications irectvent Pro is a unitized, coaxial venting system designed for use with direct vent gas or propane stoves, heaters, and fireplaces. Materials

More information

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 6" - 8", Round and Oval.

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 6 - 8, Round and Oval. Installation Instructions High-Temperature, Factory Insulated Double-Wall Masonry Relining system 6" - 8", Round and Oval DuraLiner A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES

More information

Installation Instructions

Installation Instructions Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury,

More information

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Installation Instructions Venting System For Pellet and Corn Stoves PelletVent Cornvent C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y A MAJOR CAUSE OF VENT RELATED

More information

Light Stainless Flexible Liner

Light Stainless Flexible Liner Light Stainless Flexible Liner Dalsin Line light flexible liner is listed for chimney relining and is suitable for wood, pellet, gas, oil, and coal applications. This liner is manufactured using.006 thick

More information

Ventinox. Welded, flexible and rigid relining for masonry chimney. UL 1777, ULC S635 and ULC S640.

Ventinox. Welded, flexible and rigid relining for masonry chimney. UL 1777, ULC S635 and ULC S640. Ventinox Welded, flexible and rigid relining for masonry chimney. UL 1777, ULC S635 and ULC S640. Specifications Applications VFT flexible liners are used for upgrading or restoring masonry chimneys that

More information

RENDERED TO SLEEPY HOLLOW CHIMNEY SUPPLY, LTD. 85 EMJAY BLVD. BRENTWOOD, NY 11717

RENDERED TO SLEEPY HOLLOW CHIMNEY SUPPLY, LTD. 85 EMJAY BLVD. BRENTWOOD, NY 11717 REPORT NUMBER: G100313384MID-006 ORIGINAL ISSUE DATE: May 10, 2011 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 RENDERED TO SLEEPY HOLLOW CHIMNEY

More information

Installation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro

Installation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro Installation Instructions Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System DirectVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR

More information

Index Rigid Chimney Liner, Flex & Insulation. Section 300. Wood

Index Rigid Chimney Liner, Flex & Insulation. Section 300. Wood Index 3 4 5 6 7 8 9 Section 3 Wood Page Number Vendor Product Publish Date 3 Z-Flex Heavy Flex Liner & Fittings 5/7 3-3 Z-Flex Flex Stainless Steel Flex Kits 5/7 33-34 ICC Excel Liner 6/6 35-3 Reliance

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions 600 Sanders Street, Scranton, PA 18505 w w w.olympiachimney.com Installation Information Product Information The quality and workmanship of Rhino Rigid TM is reflected

More information

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8. Model P36-NG10 P36-LP10 P36E-NG10 P36E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Gas Fireplaces P36-10 / P36E-10 Gas Fireplace Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa)

More information

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES Prepared By Office of State Fire Marshal Maine Office of Energy Resources 52 State House Station 55 Capital Street Augusta, ME 04333 Augusta,

More information

Installation and Maintenance Instructions For. Installation and Maintenance Instructions For

Installation and Maintenance Instructions For. Installation and Maintenance Instructions For Installation and Maintenance Instructions For Installation and Maintenance Instructions For Product Information General Product Information The quality and workmanship of Forever Flex TM / Pre-Insulated

More information

Online Update 10/2011 Current Print Version L820 1/2011

Online Update 10/2011 Current Print Version L820 1/2011 Online Update 10/2011 Current Print Version L820 1/2011 Product Catalog 2011-2012 eing Green, eing Responsible. DuraVent looks for feasible ways of doing business in an ecologically sound way. DuraVent

More information

Index Rigid Chimney Liner, Flex & Insulation. Section 300. Wood

Index Rigid Chimney Liner, Flex & Insulation. Section 300. Wood Index 3 4 5 6 7 8 9 Section 3 Wood Page Number Vendor Product Publish Date 3 Z-Flex Heavy Flex Liner & Fittings 5/7 3-3 Z-Flex Flex Stainless Steel Flex Kits 5/7 33-34 ICC Excel Liner 9/8 35-3 Reliance

More information

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth 28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1

More information

Fireplaces and Chimneys

Fireplaces and Chimneys Philip Noah, IAAI-CFI, Mo State-CFI Fireplaces and Chimneys Arkansas IAAI-Fall Conference October 28, 2016 Fireplace Statistics U.S. Fire Administration categorizes fireplace fires in Heating Fires. The

More information

Heavy Duty Flexible Liner

Heavy Duty Flexible Liner Heavy Duty Flexible Liner INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE

More information

Ovalizing Flexible Liners

Ovalizing Flexible Liners Installation Instructions FasNSeal Flex DuraFlex SW Ventinox Ovalizing Flexible Liners A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.

More information

female pipe. A Wall Support must be installed just above the tee and at least every 8 feet thereafter. If the pipe is to be run through a roof overhang then a Flashing, Storm Collar and Vertical Rain Cap

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720

More information

DuraChimney II Shroud

DuraChimney II Shroud Installation Instructions Dura II 10" - 16" Shroud Dura II Shroud A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR FLEXIBLE STAINLESS STEEL RELINING PIPE LISTED Lifetime Warranty UL Listed Sizes: 5" 8" diameters Manufactured Exclusively for: Copperfield Chimney Supply,

More information

DuraFlex AL. Installation Instructions

DuraFlex AL. Installation Instructions Installation Instructions Flexible aluminum relining system for relining masonry chimneys for natural gas or liquid propane category I, draft hood equipped appliances, and appliances tested and listed

More information

Installation Instructions. Pellet-fuel venting system. PelletVent

Installation Instructions. Pellet-fuel venting system. PelletVent Installation Instructions Pellet-fuel venting system. PelletVent A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST

More information

Heavy Duty Flexible Liner

Heavy Duty Flexible Liner Heavy Duty Flexible Liner INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR FLEXIBLE STAINLESS STEEL CHIMNEY RELINING PIPE UL/ULC LISTED SIZES: 3" 12" DIAMETERS.

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR FLEXIBLE STAINLESS STEEL CHIMNEY RELINING PIPE UL/ULC LISTED SIZES: 3 12 DIAMETERS. INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR FLEXIBLE STAINLESS STEEL CHIMNEY RELINING PIPE UL/ULC LISTED SIZES: 3" 12" DIAMETERS Lifetime Warranty MANUFACTURED EXCLUSIVELY FOR COPPERFIELD CHIMNEY SUPPLY,

More information

PIPE

PIPE The highest quality stainless steel liners at the best prices in the industry. The Lifetime Mission At Lifetime Chimney Supply, we make the highest quality stainless steel chimney liners, sell them at

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR FLEXIBLE STAINLESS STEEL RELINING PIPE Lifetime Warranty UL/ULC Listed Sizes: 3" 8" diameters Manufactured Exclusively for: Copperfield Chimney Supply, 304

More information

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE Model P33-NG10 P33-LP10 P33E-NG10 P33E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) Manifold

More information

Heavy Duty Flexible Liner

Heavy Duty Flexible Liner Heavy Duty Flexible Liner INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE

More information

Flexible Chimney Liners

Flexible Chimney Liners Installation Instructions Ventinox DuraFlex Pro DuraFlex SW DuraFlex 316 DuraFlex 304 TherMix ProFoil Flexible Chimney Liners A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES

More information

Installation Instructions. DuraTech 5" - 24" Chimney Shroud. DuraTech Shroud

Installation Instructions. DuraTech 5 - 24 Chimney Shroud. DuraTech Shroud Installation Instructions DuraTech 5" - 24" Shroud DuraTech Shroud A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CHIMNEY CONNECTOR WALL THIMBLE MODEL IWT INSTALLATION INSTRUCTIONS Warnock Hersey C US LISTED ULC-S641/UL103 IT IS OF THE UTMOST IMPORTANCE THAT THIS WALL THIMBLE BE INSTALLED ONLY Y IN ACCORD CCORDANCE

More information

Technical and Dimensional Data. Saf-T Vent SC

Technical and Dimensional Data. Saf-T Vent SC Technical and Dimensional Data Saf-T Vent SC 3"/5" & 4"/7" Concentric Reduced Clearance Double Wall for Special Gas Vent and/or Sealed Combustion Systems Copyright 2003 Saf-T Vent is a registered trademark

More information

EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS

More information

Regency Horizon HZ30E Gas Fireplace

Regency Horizon HZ30E Gas Fireplace Specifications: Framing Dimensions: Model HZ3E-NG HZ3E-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent

More information

Chimney Lining Systems

Chimney Lining Systems R Chimney Lining Systems Gas or Propane Fired Appliances Table of Contents 1. General Instructions and Warnings U.L. and Manufacturers Specifi cations...2 2. Types of Liner Systems...3 3. FLEXJET Installation

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3 and 4. R1001.2 Footings and foundations.

More information

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7 Gas venting DIRECT VENT PRO CVS CHIMNEY LINER B-VENT CO-LINEAR CAPS Table of Contents DirectVent 4 x 6 5/8... 2 DirectVent 5 x 8... 4 DirectVent Pro Kits... 6 DirectVent CVS... 7 DirectVent Liner Kits...

More information

Installation Instructions. Air-Cooled, All-Fuel Chimney for Fireplaces. DuraChimney ii

Installation Instructions. Air-Cooled, All-Fuel Chimney for Fireplaces. DuraChimney ii Installation Instructions Air-Cooled, All-Fuel Chimney for Fireplaces DuraChimney ii A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.

More information

Secure Black. Single and Double Wall Stove Pipe (US) (Canada)

Secure Black. Single and Double Wall Stove Pipe (US) (Canada) Secure lack Single and Double Wall Stove Pipe www.securitychimneys.com 800-361-4909 (US) 800-667-3387 (anada) Secure lack Double Wall The Secure lack Double Wall (DL) stove pipe from Security himneys is

More information

ENGLISH INSTALLATION INSTRUCTION MANUAL. N550 Bakers Oven. CERTIFIED for USA & CANADA SAFETY TESTED to UL & ULC-S

ENGLISH INSTALLATION INSTRUCTION MANUAL. N550 Bakers Oven. CERTIFIED for USA & CANADA SAFETY TESTED to UL & ULC-S ENGLISH INSTALLATION INSTRUCTION MANUAL Nectre Big Bakers Oven Operating Manual N550 Bakers Oven CERTIFIED for USA & CANADA SAFETY TESTED to UL 1482-2011 & ULC-S627-2000 CA O se re e re m efore r se r

More information

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems) C US INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems) A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN

More information

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE

More information

Masonry Thimble Chimney Serving Appliance

Masonry Thimble Chimney Serving Appliance Job #3097931 Masonry Thimble Chimney Serving Appliance Customer Name Location Address Location of the appliance in the home - Appliance Information 1A What type of appliance is installed? Stove 1B What

More information

VERSA-LINER FACTORY-BUILT LINING SYSTEM

VERSA-LINER FACTORY-BUILT LINING SYSTEM INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE VERSA-LINER FACTORY-BUILT LINING SYSTEM LISTED CAN/ULC - S635, CAN/ULC - S640, UL1777 IT IS OF THE UTMOST IMPORTANCE THAT THIS CHIMNEY LINER BE INSTALLED ONLY

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS ULEB 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS

More information

Installation SBIHA-Black single wall pipe

Installation SBIHA-Black single wall pipe Installation SBIHA-Black single wall pipe A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UPMOST IMPORTANCE THAT THE STOVE

More information

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3.

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3. P36 - P36D Zero Clearance Direct Vent Gas Fireplace Model P36-NG4 P36-LP4 P36D-NG1 P36D-LP1 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3. kpa)

More information

,167$//$7,21,16758&7,216

,167$//$7,21,16758&7,216 03/10 51001401 1 2 Page 1.0 2.0 3.0 Product Information... General Information - Size, Location and Clearances... Liner Components... 4 4-5 5 4.0 Tools and Materials... 5 5.0 6.0 7.0 8.0 9.0 10.0 11.0

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

Contemporary Collection

Contemporary Collection HZ5E Gas Fireplace Model HZE-NG HZ5E-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.9 kpa) Manifold Pressure - High 3.5 W.C. (.7 kpa) 1 W.C. (.9 kpa) Manifold Pressure

More information

Chimney and Fireplace Inspection Report

Chimney and Fireplace Inspection Report Chimney and Fireplace Inspection Report 91406 Inspection prepared for: Mr. and Mrs. Client Inspector: Greg Butler 27943 Seco Canyon Road, 560, Santa Clarita, CA 91350 NOTICE TO THIRD PARTIES: This report

More information

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. SAFETY PRECAUTIONS Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter

More information

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth P33 Zero Clearance Direct Vent Gas Fireplace P33 WITH THE FLUSH OR BAY FRONT Model P33-NG4 P33-LP4 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure

More information

Taking value to the highest level.

Taking value to the highest level. Venting Solutions Taking value to the highest level. Example: 2D Drawings Schebler Chimney Systems is a premier source of custom, modular prefabricated stainless steel chimneys, heavy wall engineered stacks,

More information

Tested to BS EN and BS EN 1443

Tested to BS EN and BS EN 1443 Tested to BS EN 1856-2 and BS EN 1443 Introduction Page 2 Midtherm Flue Systems Limited is an independent British manufacturing company producing a wide range of flue and chimney products, along with associated

More information

Installation and Operation Manual. Safety tested according to ULC-S610 and UL 127 Standards by an accredited laboratory.

Installation and Operation Manual. Safety tested according to ULC-S610 and UL 127 Standards by an accredited laboratory. FP16 Saint-Laurent Installation and Operation Manual Safety tested according to ULC-S610 and UL 127 Standards by an accredited laboratory www.valcourtinc.com Manufactured by: Stove Builder International

More information

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw) P36 / P36E Gas Fireplace Model P36-NG10 P36-LP10 P36E-NG10 P36E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) 5 W.C. (1.25 kpa) 11

More information

Exceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved

Exceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved Exceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved Chimneys Liners Renewables The trusted name for Multifuel flexible liners for over 30 years

More information

Description/Application Maximum Temperature Continuous Firing Maximum Temperature Intermittent Firing Fuel Construction Diameters: Insulation

Description/Application Maximum Temperature Continuous Firing Maximum Temperature Intermittent Firing Fuel Construction Diameters: Insulation Description/Application Double wall air or optional fiber insulated positive pressure system for venting boilers, kilns, grease ducts, emergency generators, caustic air, coffee roasters, bagel ovens, bread

More information

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit)

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit) Flue gas kit DN60 rigid in the duct 100193 Flue gas kit No Outlet set plastic 1 x Set 100193 39.10 (Quantities in the image differ from the set) 1003253 1001938 Spacer set * ( pieces) Top inspection opening

More information

Z-Vent Model SVE Series III

Z-Vent Model SVE Series III Special Stainless Steel Venting System for Gas Burning Appliances Category I, II, III, & IV Tested and Listed By Underwriters Laboratories Inc. UL 1738 & BH636 Note the following before installation of

More information

Installation Instructions. PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Flex

Installation Instructions. PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Flex Installation Instructions PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro Flex A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES

More information

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

EPV Pellet Vent Pellet Stove Venting System Installation Instructions EPV Pellet Vent Pellet Stove Venting System Installation Instructions A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

Midtherm Vitrelux flue pipe is available from stock, in the following standard colours and diameters, unless otherwise stated:

Midtherm Vitrelux flue pipe is available from stock, in the following standard colours and diameters, unless otherwise stated: Introduction Midtherm Flue Systems Limited is an independent ritish manufacturing company producing a wide range of flue and chimney products, along with associated components and services. Established

More information

B36XTCE Gas Fireplace

B36XTCE Gas Fireplace Model B3XTCE-NG1 B3XTCE-LP1 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C./C.E. (1.5 kpa) 11 W.C./C.E. (.7 kpa) Manifold Pressure - High 3.5 W.C./C.E. (.7 kpa) 1 W.C./C.E. (.9 kpa) Manifold

More information

O B R O U N D G R E A S E D U C T

O B R O U N D G R E A S E D U C T TM O B R O U N D G R E A S E D U C T SlimVent OBROUND GREASE DUCT SlimVent is a UL Classified zero-clearance grease duct system with the space saving profile of a field fabricated rectangular product.

More information

Even the sky is no limit.

Even the sky is no limit. Chimney Systems Even the sky is no limit. Schebler Chimney Systems is a premier source of custom, modular prefabricated chimneys, grease ducts, boiler flues, generator exhaust, breeching and heavy-wall

More information

SI T T FST

SI T T FST SI 440-600-700-700T-780-780T-900-1100 Freestanding TAPER TOP Open Fire - Wood Burner Installation Instructions Note: FLUE SYSTEMS Casing. Flue System may require to be Doubled Lined to Comply. Ref ASNZS:2918:2001

More information

TUBINOX. 5", 6", 7" & 8" Dia. INSTALLATION AND OPERATING INSTRUCTIONS. liquid or gaseous fuel burning c 2100 F. ul-1777

TUBINOX. 5, 6, 7 & 8 Dia. INSTALLATION AND OPERATING INSTRUCTIONS. liquid or gaseous fuel burning c 2100 F. ul-1777 TUBINOX factory-built lining system INSTALLATION AND OPERATING INSTRUCTIONS 5", 6", 7" & 8" Dia. for use in existing or new masonry chimneys for use with solid liquid or gaseous fuel burning appliances

More information

Rediflow Concrete Gas Flue System

Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN

More information

TOWNSHIP OF FALLS USE & OCCUPANCY FACT SHEET

TOWNSHIP OF FALLS USE & OCCUPANCY FACT SHEET TOWNSHIP OF FALLS USE & OCCUPANCY FACT SHEET A CERTIFICATE OF USE & OCCUPANCY SHALL BE REQUIRED FOR ANY OF THE FOLLOWING REASONS: 1. Occupancy and Use of any building or portion thereof hereafter erected

More information

SI T T FSS/FSTT Open Fire

SI T T FSS/FSTT Open Fire SI 440-600-700-700T-780-780T-900-1100 FSS/FSTT Open Fire Freestanding Solid Fuel Burner - Indoor Open Wood Fire Available in Square Top or Taper Top Options Installation Instructions Note: Flue System

More information

Sflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves

Sflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves Sflue TOVE Sflue TOVE Twin Wall Flue Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves 100% Manufactured in the UK Terminals Page 8 Storm ollar Page 9 Introduction

More information

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2316 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 10 00

More information

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro Installation Instructions Venting System For Direct Vent Gas Stoves and Fireplaces DirectVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro Installation Instructions Venting System For Direct Vent Gas Stoves and Fireplaces DirectVent Pro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE

More information

RECEIVING AND INSPECTION

RECEIVING AND INSPECTION Non-Welded Double Wall Grease Duct/Type HT Chimney Systems Installation, Operation, and Maintenance Manual FOR YOUR SAFETY TWO MAJOR CAUSES OF GREASE DUCT RELATED FIRES: (1) FAILURE TO MAINTAIN REQUIRED

More information

Sflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves

Sflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves TOVE Sflue TOVE Sflue Twin Wall Flue Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves 100% Manufactured in the UK Introduction Sflue chimney system has

More information

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection 1XTE-1 Gas Fireplace Model 1XTE-NG1 1XTE-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5 W.C. (.7 kpa) 1. W.C. (. kpa)

More information

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual Please see IB series product installation guide for details of installing the gas fire into this preformed metal cavity. Important: The appliance

More information

LOPI FIREPLACE INSERT MODEL X INSTALLATION, OPERATION AND MAINTENANCE HANDBOOK. JUNE 1988 Tested to UL 907 (U.S.A.) ULC S628 (Canada)

LOPI FIREPLACE INSERT MODEL X INSTALLATION, OPERATION AND MAINTENANCE HANDBOOK. JUNE 1988 Tested to UL 907 (U.S.A.) ULC S628 (Canada) , n. OWNER"S MANUAL LOPI FIREPLACE INSERT MODEL X INSTALLATION, OPERATION AND MAINTENANCE HANDBOOK JUNE 1988 Tested to UL 907 (U.S.A.) ULC S628 (Canada) 1 We welcome you as a new owner of a LOPI wood heating

More information

the heart of a warm home

the heart of a warm home the heart of a warm home INSTALLATION HANDBOOK FOR THE FIRENZO INSERT RU FIRES RURAL WOODFIRE THIS FIRE CAN ONLY BE INSTALLED ON PROPERTIES OVER 2 HECTARES The Appliance and Flue System must be installed

More information

InoxSabiana 25 Flues. Stainless Steel Double Wall

InoxSabiana 25 Flues. Stainless Steel Double Wall Cert. n 0545/5 Flues Stainless Steel Double Wall Introduction and main constructional characteristics Double Wall, Stainless Steel Flues The is the result of innovative development based on over 0 years

More information

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2599 Reissued 04/2018 This report is subject to renewal 04/2020. DIVISION: 10 00

More information