801-MORD Mordred FIXING: Ground. ORDER No: CUSTOMER: Complied by Date AB 30/06/15 ISSUE ECN DATE SIGN /07/15 AB
|
|
- Belinda Holmes
- 6 years ago
- Views:
Transcription
1 CUSTOMER: 0-MORD Mordred ORDER No: FIXING: Ground Complied by Date 0/0/5 ISSUE ECN DATE SIGN 0 7 0/07/5
2 CUSTOMER: 0-MORD Mordred ORDER No: FIXING: Ground Low tower.m single slide Low scramble net High fireman's pole Modified high tower with curved climbing net below Complied by Date 0/0/5 ISSUE ECN DATE SIGN 0 7 0/07/5
3 CUSTOMER: 0-MORD Mordred ORDER No: FIXING: Ground square x 55 deep square x 0 deep Foundations - 00 x 00 x 75 deep - 00 x 00 x 75 deep - 00 x 00 x 75 deep Complied by Date 0/0/5 ISSUE ECN DATE SIGN 0 7 0/07/5
4 CUSTOMER: 0-MORD Mordred ORDER No: FIXING: Ground R500 R500 R500 R500 0mm R750 R750 R500 0mm R000 R Safety surfacing 5m² of wetpour with 9.5m edging.5m² of 0mm thick wetpour.5m² of 0mm thick wetpour Complied by Date 0/0/5 ISSUE ECN DATE SIGN 0 7 0/07/5
5 CUSTOMER: 0-MORD Mordred ORDER No: FIXING: Ground Safety surfacing 9m² of tiles with m edging 0 tiles of 0mm thick 9 tiles of 55mm thick Complied by Date 0/0/5 ISSUE ECN DATE SIGN 0 7 0/07/5
6 CUSTOMER: 0-MORD Mordred ORDER No: FIXING: Ground Safety surfacing grassmats (m x.5m) Complied by Date 0/0/5 ISSUE ECN DATE SIGN 0 7 0/07/5
7 Castle Range Curved climbing net PROD. CODE SIZE AGE RANGE F/ FALL HEIGHT HEAVIEST PART TOTAL WEIGHT x 75 x 95 years to adult 5 Approx.75 kg Approx 0 kg SPECIFICATION Welding to EN ISO : 0 Steel plate to EN 005-: 00 Paint to EN : 005 Steel CHS to EN 055-: 00 Standard fixings to BS 9: 00 and BS 90: 00 Non-standard fixings are anti-vandal and corrosion resistant Steel-reinforced braided nylon rope with aluminium fittings INSTALLATION INSTRUCTIONS Read instructions thoroughly before commencing installation of unit Offer up the frames to the tower uprights as shown and secure in place with fixings shown NOTE Ensure the rope assembly is fitted the correct way up Note Note ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE 5-0 Page of
8 Ensure lugs are uppermost Ensure the ferrules are above the rope step ie the rope bends down 7 5 ITEM 5 7 COMPILED DATE: /0/5 QTY REV ECN SIG. DATE: PARTS LIST PART NUMBER DESCRIPTION 0- CURVED FRAME - CURVED NET ASSY 7-05 NBT SADDLE WASHER 0-0 M0 x 0 Stud 5-59 Wicksteed Washer M0 Safety Fastener 7- M0 x 0 Pent Button Head 7-0 Mx Grub Screw 0 7 0/07/5 5-0 Page of
9 Castle Range Low scramble net PROD. CODE SIZE AGE RANGE F/ FALL HEIGHT HEAVIEST PART TOTAL WEIGHT x 5 x 0 years to adult 0 Approx kg Approx 5 kg SPECIFICATION Solid steel components to EN 007: 99 Steel CHS to EN 055-: 00 Welding to EN ISO : 0 Standard fixings to BS 9: 00 and BS 90: 00 Non-standard fixings are anti-vandal and corrosion resistant Steel-reinforced braided nylon rope with aluminium fittings INSTALLATION INSTRUCTIONS Read instructions thoroughly before commencing installation of unit Excavate foundations as shown Attach net to tower and below ground fixings as shown Fit spragging irons to the below ground fixings and position on bricks in excavated holes, ensuring the net remains taut 5 Backfill the foundations with 0.0m³ concrete ( parts gravel/ parts sand/ part cement) Allow concrete to set for hours before first use Note Note ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE 5-0 Page of
10 Foundation details Care must be taken in abnormal conditions square 750 (5) (75 for bark) Brick 5-0 Page of
11 Behind curved deck edge 7 A Against HDPE panel 5 A ( / ) ITEM 5 7 COMPILED DATE: 7/0/5 QTY REV ECN SIG. DATE: PARTS LIST PART NUMBER DESCRIPTION BELOW GROUND FIXING ASSY - LOW NET ASSY 0-5 RAPID LINK 0-00 SPRAGGING IRON 5-59 Wicksteed Washer -0 M0 Spring Washer 7-9 M0 x 50 Pent Button Head 7-0 Mx Grub Screw For Bark - Replace item with /0/5 5-0 Page of
12 Castle Range High fireman's pole PROD. CODE SIZE AGE RANGE F/ FALL HEIGHT HEAVIEST PART TOTAL WEIGHT x 95 x 070 years to adult 5 Approx kg Approx.5 kg SPECIFICATION Steel plate to EN 005-: 00 Steel CHS to EN 055-: 00 Welding to EN ISO : 0 Paint to EN : 005 Non-standard fixings are anti-vandal and corrosion resistant INSTALLATION INSTRUCTIONS Read instructions thoroughly before commencing installation of unit Excavate foundations as shown in foundation plan Place pole on a brick in the excavated foundation and secure to tower as shown, ensuring pole is vertical Backfill foundation hole with 0.0m³ concrete ( parts gravel/ parts sand/ part cement) 5 Allow concrete to set for hours before first use Note Note ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE 5-07 Page of
13 Foundation details Care must be taken in abnormal conditions square (07) () 5 Bark Round off concrete Page of
14 5 ITEM 5 QTY PARTS LIST PART NUMBER DESCRIPTION WELDED MONKEY POLE SLIDER 0- HIGH POLE ASSY 5-59 Wicksteed Washer M0 Safety Fastener 7-7 M0 x 5 Pent Button Head 7- M0 x 5 Pent Button Head ITEM 7 9 COMPILED DATE: /0/5 QTY REV ECN SIG. DATE: FOR BARK FIX ADD PART NUMBER DESCRIPTION BELOW GROUND ASSY 0-00 SPRAGGING IRON 75- M x 5 LG HEX HD SCREW 0 7 0/07/ Page of
15 PROD. CODE SIZE Castle Range Double tower AGE RANGE F/ FALL HEIGHT HEAVIEST PART TOTAL WEIGHT x 75 x 5 years to adult Approx 5 Approx kg Approx 7 kg SPECIFICATION Solid steel components to EN 007: 99 Welding to EN ISO : 0 Steel plate to EN 005-: 00 Paint to EN : 005 Steel RHS to EN 00-: 997 HDPE to EN ISO : 99 Standard fixings to BS 9: 00 and BS 90: 00 Non-standard fixings are anti-vandal and corrosion resistant INSTALLATION INSTRUCTIONS Read instructions thoroughly before commencing installation of unit Excavate foundations as shown in the foundation plan Attach the towers together as shown, fitting the step panel and handrails. Note - some of the plates on the bottom of the legs on the short tower need to be cut back Position tower on bricks in the excavated foundations, ensuring it is plumb, square and at the correct height, orientation and distance 5 When the unit is fully assembled and all fixings secure, backfill the foundations with 0.7m³ of concrete ( parts gravel/ parts sand/ part cement) Allow concrete to set for hours before first use Note Note ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE 5-0 Page of
16 Foundation details Care must be taken in abnormal conditions square Bricks Cut back plates on short tower Loosefill Round off concrete Brick 5-0 Page of
17 Tower assembly details Page of
18 ITEM QTY PARTS LIST PART NUMBER DESCRIPTION 5-07 HIGH TOWER (FOR DOUBLE ASSY) 5-00 LOW TOWER STEP PANEL FIXING WASHER -0_Cup Black Poepplemann Cup -0_Cap Black Poepplemann Cap FIXING SPACER (5 panel) 5-59 Wicksteed Washer 9-00 M0 Binx Nut 5-0 M0 x 0 LG HEX HD SCREW 7-0 M0 x 75 Pent Button Head ITEM QTY FOR BARK FIX ADD PART NUMBER DESCRIPTION BELOW GROUND ASSY 0-00 SPRAGGING IRON 75- M x 5 LG HEX HD SCREW COMPILED DATE: 0/0/5 REV ECN SIG. DATE: 0 7 minor minor 0/07/50//55/0/ 5-0 Page of
19 Tropica.m SINGLE SLIDE PROD. CODE SIZE AGE RANGE F/ FALL HEIGHT HEAVIEST PART TOTAL WEIGHT 900/900 00x00x Up to years 00mm Approx kg Approx 7.5 kg SPECIFICATION Chute: Made from mm stainless steel sheet Guardrail: Made from Nominal bore tube to BS7 Pedestals: Made from circular hollow section to BS Fixings: Anti-vandal and corrosion resistant Welds: Copper-free conforming to 90AIB for mild steel Finish: Low lead polyester powder paint to BSEN7 INSTALLATION INSTRUCTIONS Note:- In accordance with.. EN7-:00 we recommend that slides do not face south or near due south due to heat build up Read installation instructions through before commencing erection of unit Do NOT tighten fastenings until the unit is completely assembled Excavate foundations as shown in the diagram on page Place pedestals in the foundations and prop up in position 5 Ensuring pedestals are plumb, square and upright, and at the correct height and centre of the dimensions, backfill foundations with concrete Allow hours drying time before fixings slide to pedestals Note Note M bolts to be torqued to Nm (lbft). M0 bolts to be torqued to Nm (5lbft) M bolts to be torqued to 55Nm (0lbft). All protruding screw threads to be peened over to remove sharp edges. Lifting aid will be required when installing this piece of equipment ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE 900/900 Page of 5
20 Foundations detail (Care must be taken under abnormal conditions) 59 Tower RUN-OFF Underside of slide runout to finished surface shall be a maximum dimension of 00mm Brick Foundation detail Ground fixed 500 x 500 x 75 RUN-OFF Underside of slide runout to finished surface shall be a maximum dimension of 00mm Brick Foundation detail Bark fixed 500 x 500 x /900 Page of 5
21 Surfacing & free space detail R500 R500 R000 Free space 7 7 Fixing pedestals to chute To fit pedestals to chute use M x 5 pent button head screw, placing an M fibre washer either side of the pedestal top plate Ensure spragging iron is in place before back filling the foundations /900 Page of 5
22 End plug detail Insert the two plastic plugs into slide barrier spigots before securing to slide and tower 9 0 Fixing detail to tower Attach slide and barrier to tower using M0 x 5 pent button head screws and Wicksteed washers Drill through tower uprights to fit M0 x 50 pent button head screw, M0 and M washers and M0 safety fastener to prevent possible traps 900/900 Page of 5
23 ITEM QTY PARTS LIST PART NUMBER DESCRIPTION SINGLE SLIDE BARRIER SINGLE SLIDE CHUTE ASSY 0-0 PEDESTAL SUPPORT LEG - RUNOUT 0-07 PEDESTAL SUPPORT LEG - MIDDLE 0-0 SPRAGGING IRON -005 END PLUG (¼ NB) 57-0 M Fibre Washer 5-59 Wicksteed Washer M Plain Washer 5-50 M0 Washer M0 Safety Fastener 7-7 M x 5 Pent Button Head 7-9 M0 x 50 Pent Button Head 7- M0 x 5 Pent Button Head COMPILED DATE: /0/ REV ECN SIG. DATE: minor /0/ 900/900 Page 5 of 5
24 DESPATCH LIST Sheet of Product: 0-MORD Mordred Date of Issue: /0/5 Order No: Issue: A Item Unit Qty Description Part No. Checked Items marked * to be fitted before despatch High tower (mod) assembly 0-5 Deck bottom panel * Deck top panel * Low tower assembly 0-5 Step panel Curved frame 0- Curved net assembly - 9 Below ground fixing assembly Low net assembly - High pole assy 0- Single slide barrier Single slide chute assembly Pedestal support leg - runout Pedestal support leg - middle 0-07 Welded monkey pole slider Fixing pack Total No. of Items Picked By: Checked By: COMPILED REV 0 BY: ECN No. 7 minor minor DATE /0/5 0//5 5/0/ DATE: /0/5 SIGN
25 FIXINGS LIST Sheet of Product: 0-MORD Mordred Date of Issue: /0/5 Order No: Issue: A Item Unit Qty Description Part No. Checked Double tower Fixing washer * Black Poeppelmann cup * -0 Black Poeppelmann cap * -0 Fixing spacer (5 panel) * Wicksteed washer * 5-59 M0 binx nut * M0 x 50 hex head bolt * 5-0 Fixing washer Black Poeppelmann cup -0 0 Black Poeppelmann cap -0 Fixing spacer (5 panel) Wicksteed washer 5-59 M0 binx nut 9-00 M0 x 75 pent button head screw M0 x 0 hex head screw 5-0 High fireman's pole 7 Wicksteed washer 5-59 M0 x 5 pent button head screw 7-9 M0 x 5 pent button head screw M0 safety fastener Items marked * to be fitted before despatch Total No. of Items Picked By: Checked By: COMPILED REV 0 BY: ECN No. 7 minor minor DATE /0/5 0//5 /0/ DATE: /0/5 SIGN
26 FIXINGS LIST Sheet of Product: 0-MORD Mordred Date of Issue: /0/5 Order No: Issue: A Item Unit Qty Description Part No. Checked Curved climbing net NBT saddle washer 7-05 M0 x 0 stud 0-0 Wicksteed washer 5-59 M0 safety fastener M0 x 0 pent button head screw 7- M x grub screw 7-0 Low scramble net 7 Rapid link 0-5 Spragging iron Wicksteed washer M0 spring washer -0 M0 x 50 pent button head screw 7-9 M x grub screw 7-0.m single slide Spragging iron 0-0 M fibre washer Wicksteed washer 5-59 M x 5 pent button head screw M0 x 5 pent button head screw 7- M0 x 50 pent button head screw M0 washer 5-50 Items marked * to be fitted before despatch Total No. of Items Picked By: Checked By: COMPILED REV 0 BY: ECN No. 7 minor minor DATE /0/5 0//5 /0/ DATE: /0/5 SIGN
27 FIXINGS LIST Sheet of Product: 0-MORD Mordred Date of Issue: /0/5 Order No: Issue: A Item Unit Qty Description Part No. Checked.m single slide (cont) 0 M washer M0 safety fastener End plug (¼ NB) * -005 M0/M pent key 7-00 Items marked * to be fitted before despatch Total No. of Items Picked By: Checked By: COMPILED REV 0 BY: ECN No. 7 minor minor DATE /0/5 0//5 /0/ DATE: /0/5 SIGN
WARNING- THIS EQUIPMENT IS DESIGNED FOR ADULTS ONLY. ONLY HEALTHY PEOPLE AGES 13 AND UP SHOULD USE THE EQUIPMENT.
INSTALLATION DETAILS Recommended crew (Adult): 2 Installation time: 2 hours (plus time for concrete to cure) User age: 13 and up Weight: 163 lbs MAINTENANCE: As the owner of the equipment you are responsible
More informationCOPYRIGHT 2001 BY: GAMETIME REVISED: 08/09/01
COPYRIGHT 2 BY: GAMETIME REVISED: 8/9/ 627 FITKID PARALLEL BAR NOTE: 627 2'-6" PARALLEL BAR 628 3' PARALLEL BAR 629 3'-" PARALLEL BAR 63 3'-6" PARALLEL BAR 63 3'-" PARALLEL BAR 632 '-2" PARALLEL BAR 633
More informationSPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:
SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN 1. SCOPE This specification covers the design, fabrication and testing of tubular section, galvanised steel friction fit jointed street light columns of
More informationCode Compliance Research Report CCRR-0238
Code Compliance Research Report CCRR-0238 Issue Date: 11-09-2016 Revision Date: 11-29-2018 Renewal Date: 11-09-2019 DIVISION: 05 00 00 METALS Section: 05 52 00 Metal Railings CPG Building Products LLC
More informationFitTech UP166F CHEST PRESS (FOOTING) UP166I CHEST PREES (IN GROUND) UP166S CHEST PRESS (SURFACE)
CHEST PRESS BASE COVER DESCRIPTION FOOTBUCK WELD ASSEMBLY HARDWARE COMPLETE HARDWARE COMPLETE HARDWARE COMPLETE /" ANCHOR ROD 3/" x " HEX HEAD CAP SCREW 3/" WEDGE ANCHOR 3/" ANCHOR BOLT 3/" FLATWASHER
More informationInstallation Manual For Conical Tanks. INSTALLATION and MAINTENANCE INSTRUCTIONS FOR CONICAL TANKS
INSTALLATION and MAINTENANCE INSTRUCTIONS FOR CONICAL TANKS Page 1 of 10 INDEX 1. Health & Safety 3 2. Introduction 3 3. Requirements 3 4. Working Area 3 5. Equipment 3 6. 2 and 3 metre tank above ground
More informationCode Compliance Research Report CCRR-0238
Code Compliance Research Report CCRR-0238 Issued: 11-09-2016 Renewal Due: 11-09-2018 Revised: 11-10-2017 DIVISION: 05 00 00 METALS Section: 05 52 00 Metal Railings CPG Building Products LLC 894 Prairie
More informationFitTech UP171F ELLIPTICAL (FOOTING) UP171I ELLIPTICAL (IN GROUND) UP171S ELLIPTICAL (SURFACE) Parts List
ELLIPTICAL BASE COVER DESCRIPTION FOOTBUCK WELD ASS'Y HARDWARE COMPLETE HARDWARE COMPLETE HARDWARE COMPLETE /" ANCHOR ROD 3/" x " HEX HEAD CAP SCREW 3/" WEDGE ANCHOR 3/" ANCHOR BOLT 3/" FLATWASHER (" O.D.)
More information.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)
Fitness Facility Addition Page 1 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 03300 - Cast-in-Place Concrete.2 Section 05121 - Structural Steel for Buildings.3 Section 05500 - Metal Fabrications 1.2 REFERENCES.1
More informationFEATURES APPLICATIONS. Technical data sheet SSW - STEEL STRONG-WALL FOR TIMBER FRAME RACKING RESISTANCE.
The Steel Strong-Wall is a corrugated steel panel which is designed to be fixed directly to the concrete foundations of a building, within the external or internal wall, via a bolted connection. FEATURES
More informationAssembly and users manual. Pallet racking Alfa
Assembly and users manual Pallet racking Alfa ASSEMBLING OF FRAMES Tightening Torque Screw M0 8.8 Max. tightening torque 7 Nm Taptite M6 Max. tightening torque 5 Nm Taptite M8 Max. tightening torque 5
More informationElectrical Services Standard Specification Cable Tray Installation. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON
Electrical Services Standard Specification 4.0 - Cable Tray Installation May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood Consulting Engineers Ltd
More informationStainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K
T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces
More informationH 12 Heavy Duty Modern Tripod 8 Seat Swing Heavy Duty Hangers
Page 1 IMPORTANT Please retain this instruction sheet in your files. It contains important replacement parts information. All equipment should be installed in accordance with these instructions. It is
More information" RISKS ASSOCIATED WITH THE INSTALLATION OF THE SYSTEM
PALLET RACK 85-110 installation, use and maintenance instructions Shelving made entirely of first grade certified steel sheet and cold-profiled steel with galvanized steel according to SENDZIMIR process
More informationUniversal Elevator Mount Owners Manual
REQUIRED TOOLS AND MATERIALS: 2 Capable Adults Universal Elevator Mount Owners Manual 1-00-spalding Carpenter s Level 15 Tape Measure Pencil Adult Assembly Required. This manual, accompanied by sales receipt,
More informationHuck Seiltechnik GmbH Aßlar/Berghausen Germany
Seiltechnik GmbH 35614 Aßlar/Berghausen Germany A Assembly Instructions Arch Swing with Buried Ground Anchors Art-No. 4580-4B Operator: Location: T:\PLAY\Play Installation Instructions\Word Document Install
More informationINSTALLATION MANUAL IN-GROUND
INSTALLATION MANUAL IN-GROUND Dig holes according to positions on drawings (see the following pages). Dimensions of holes: e.g. 50 x 50 x 75 cm (see the following pages). Fill with concrete leaving a depth
More informationInstallation Instructions Easy Climb 1 Art
Installation Instructions Easy Climb 1 Art. 4591-40-1 Operator: Location: Revision history Revision 0 2009-08-21 The first allowed version Assembly instruction Revision 1 2011-08-12 B25 in C25/30 u. Fallschutz
More informationHighways Square Trolley Pole. HSTP Range. Sales Direct: +44 (0) w: e: Highways Square Trolley Pole
The brand new HSTP is the latest innovation in square CCTV trolley poles and is an ideal column for urban and traffic CCTV schemes. Built to complement our extensive range of highway masts as well as boasting
More informationCONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 616 APRIL 2018 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03 DEFINITIONS
More informationA Assembly instructions Maxi Cheops pyramid (registered design) Art B to set into concrete
Seiltechnik A Assembly instructions Maxi Cheops pyramid (registered design) Art. 4643-3B to set into concrete LEDON:Produktudvikling:huck montagevejledninger:4643_3b-01-en-005.doc - 1 - Seiltechnik Huck
More information1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.
SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2
More informationRadiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT
Radiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT 2-2012 The PV-RoofTopRac System has been developed as a universal system for roof-mounting on pitched roofs.
More informationTEMPORARY EDGE PROTECTION SYSTEM DESCRIPTION CTS. Combisafe International AB
TEMPORARY EDGE PROTECTION SYSTEM DESCRIPTION CTS Combisafe International AB CTS Combisafe International AB Contents Safety instructions... 3 Important... 4 General... 4 Data... 5 Safety posts 4140/4145/4150...
More informationAegis Heavy Capacity 20K Floor Scale. MODEL: 6200 Series. Installation Manual
Installation Manual Aegis Heavy Capacity 20K Floor Scale MODEL: 6200 Series Copyright 1997-2014 Fairbanks Scales, Inc. Revision 3 50637 All Rights Reserved 07/14 Aegis Heavy Capacity 20K Floor Scale Model:
More informationAssembly instructions Fortuna Play Course Art part
A Assembly instructions Fortuna Play Course Art.4591-65 3-part Operator: Location: LEDON:Produktudvikling:huck montagevejledninger:4591-65 3er-en-002.doc - 1 - Revision history Revision 0 2010-12-07 The
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationIMPORTANT. Use of safety surfacing (wood mulch) in compliance with ASTM specification F1292 is required. WARNING
INSTALLATION DETAILS Recommended crew (Adult): 2-3 Installation time: 8-12 Hours not including concrete cure time User age: 5-12 Use zone: 22 Diameter Weight: 990 Actual Dimension: 120 Diameter MAINTENANCE:
More informationAppendix 4. Bills of Quantities
Appendix 4. Bills of Quantities 201 A4.1 Deep trench latrines Partitions of local materials 1m apart Timber foot rests and floor plates Lightweight timber frame Excavated soil (used for back-fill) Plastic
More informationCONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 616 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB #
SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationDOC NO. ISSUE Page Date. GVTG of LARGE COLUMN ASSEMBLY & INSTALLATION DIAGRAM GENERAL
of 5.0 GENERAL The purpose of this technical procedure is to detail those actions necessary to ensure that Large Columns are joined in compliance with the applicable design standards. Columns come in tapered
More informationManufacturing Capabilities. Very few companies in the industry are able to provide the same extent of services under one roof
Manufacturing Capabilities Our extensive range of manufacturing processes gives us the ability to supply to many different industry sectors. By utilising our design department and the extensive knowledge
More informationBETTER BY DESIGN BRICK SLIP MASONRY SUPPORT INSTALLATION INSTRUCTIONS. igmasonrysupport.com
BETTER BY DESIGN BRICK SLIP MASONRY SUPPORT INSTALLATION INSTRUCTIONS KEY CONSIDERATIONS FOR CORRECT INSTALLATION To achieve the design capacity of the product, it must be installed in the correct manner.
More informationSECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.
SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Handrails and guardrails B. Guardrails for hatches and openings. C. Safety barriers. D. Roof edge protection. 1.2 RELATED SECTIONS
More informationCode Compliance Research Report CCRR-0187
Code Compliance Research Report CCRR-0187 Issue Date: 11-29-2012 Revision Date: 07-24-2018 Renewal Date: 02-28-2019 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 63 00 Plastic Railings REPORT
More informationPATHWAYS FOR COMMUNICATIONS SYSTEMS
270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This
More information1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.
BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 7 PART 1 GENERAL 1.1 REFERENCES.1 American Society of Mechanical Engineers (ASME).1 ASME B31.1, Power Piping, B31.3 Process Piping, B31.9 Building Services Piping..2
More informationPLAYGROUND FENCING AND GATES
PLAYGROUND FENCING AND GATES We offer a variety of solutions in timber and steel for school, playground and play area applications where security, safety, durability and sustainability are key considerations.
More informationHALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel
HALSEY TAYLOR OWNERS MANUAL Classic TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HTERQ Figure HTSRQ Figure 3 HTSERQ Figure HTESRQ Figure 3 Model HTERQ HTSRQ HTSERQ
More informationDivision 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17
07 21 16 Blanket Insulation Page 1 of 17 Design Number UNI/BI 120-03 FIRE RESISTANT GREASE DUCT Unifrax I LLC FyreWrap Elite 1.5 Duct Insulation CAN/ULC S144 Fire Resistance Rating 2 hours Fire Inside
More informationKind of document : Assembly manual
Stalprodukt S.A. Kind of document : Assembly manual Reference No: IM/MD-49/16 Title : ASSEMBLY MANUAL OF ROAD SAFETY BARRIER StalPro Rail hd according to EN 1317-5:2007+A2:2012 Page: 1 Issue No:III Pages:
More informationZS880 Linear Shower Drain Installation Instructions
Introduction PATENT PENDING The Zurn ZS880 Stainless Steel Linear Shower Drain incorporates a simple approach to bathroom shower design, when compared to traditional point-drain applications. The linear
More informationSPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S
SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...
More informationCONSTRUCTION SPECIFICATION FOR POLE ERECTION
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 615 SEPTEMBER 1993 CONSTRUCTION SPECIFICATION FOR POLE ERECTION 615.01 SCOPE 615.02 REFERENCES 615.05 MATERIALS TABLE OF CONTENTS 615.05.01 Concrete.02
More informationPROVEN 15/TM1500 FOUNDATION INSTRUCTIONS
PROVEN 15/TM1500 FOUNDATION INSTRUCTIONS Foundation Pack for Proven 15/TM1500 PACKING LIST LIST OF PARTS TO BE SENT WITH BASE PLATE 1 - GALVANISED BASE PLATE 10 M36 FOUNDATION RODS WITH BOSSES FITTED 10
More informationSECTION ORNAMENTAL ALUMINUM FENCING
SECTION 032300 ORNAMENTAL ALUMINUM FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMultidirectional_scaffolding MP
Multidirectional_scaffolding MP 162 Company Projects Products Scaffoldings and Coverings MP MULTIDIRECTIONAL SCAFFOLDING The MP multidirectional system is the modern solution that reflects in an industrialized
More informationModel # 357-MC. 8/13/2018 Page 1 of 12
Model # 357-MC 8/13/2018 Page 1 of 12 /13/2018 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationStandard Installation Fire Damper Models: 119, 119(F), 119(SS), D19
Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the
More informationThe Safety Solution for Free Standing Roof Edge Protection
S A F E T Y A T T H E H I G H E S T L E V E L Systems The Safety Solution for Free Standing Roof Edge Protection PROVIDES COLLECTIVE PROTECTION FOR ALL ROOF TOP WORKING MEETS THE REQUIREMENTS OF THE WORKING
More informationROOF MOUNT KIT OWNERS MANUAL
ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF
More informationCANTILEVER IPE
IPE 90-120 RAL 3000 Columns RAL 1004 Shelves Galvanized crosses and accessories Freestanding shelving particularly suitable for the storage of long materials such as pipes, bars, sections, sheets in packs,
More informationPASSPORT IS ROLLER GUIDE POST FENCE LINE GATE OPENING ROLL GATE SAFETY WARNING
PASSPORT PASSPORT II 2"sq x 12ga UPRIGHTS & DIAGONAL BRACES 2.75"sq PALES 2" x 4" x 11ga BOTTOM RAIL (notched & plated for v-track wheels) FENCE LINE LATCH A ROLLER GUIDE POST LATCHING POST ROLLER GUIDE
More informationFixed & Tilt-Over Cabinet Base TC & TCTO Range
TC & TCTO Range Technical Specification All dimensions in mm unless otherwise stated Standards Applicable - Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997 - General Steelwork: BS1449:1991,
More informationHFX Adhesive Anchor Adhesive Anchoring Systems
HFX Adhesive Adhesive ing Systems MD300 Dispenser HFX-M Mixer HFX Cartridge Standard Silicon Dispenser Product Description Hilti HFX is a new hybrid adhesive mortar combining resin, hardener, cement and
More informationSECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and
More information1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.
PAGE 051200-1 SECTION 051200 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,
More informationConcrete Screw-Anchors
Screw-Anchors Screw-Anchor are a totally removable rotation setting, thread forming anchor, ideal for either temporary or permanent anchoring into substrates such as concrete, brick, hollow brick or block.
More informationSECTION 2 DIVISION 05 METALS
SECTION 2 DIVISION 05 METALS DIVISION 5 - METALS Note: This is a guide for Designers only. Contents shall not be used in lieu of specifications as part of the Designer s Contract Documents. GENERAL DESIGN:
More informationassembly and installation guide
The Arqua Fountain DF4 is a high-quality water bubbler designed to provide accessible, fresh drinking water in public environments. This technical pack includes: Assembly and Installation guide Care and
More informationDIVISION 2 - SITE WORK
Montgomery County Public Schools Facilities Guide DIVISION 2 - SITE WORK Conditions of Use/ Responsibility of Data These guideline specifications are to be used by the A/E as a base document in the development
More informationDivision 11 - Equipment Section 11401
PART 1 - GENERAL 1.1 GENERAL A. Division 1 General Requirements applies and becomes a part of this Section of the Specification as fully as if repeated herein. B. Items of equipment which are included
More informationFeatures Advantages Benefits
What is BoxBolt? A KEE SAFETY PRODUCT BoxBolt Guide - Eurocode 3 / DIN 18800 BOXBOLT is a fully tested and approved blind fixing solution for connecting to hollow section steelwork or where access is restricted
More informationHALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel
HALSEY TAYLOR OWNERS MANUAL Classic TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HTERQ Figure HTSRQ Figure 3 HTSERQ Figure HTESRQ Figure 3 Model HTERQ HTSRQ HTSERQ
More informationARCHITECTURAL SPECIFICATIONS
ARCHITECTURAL SPECIFICATIONS I. GENERAL 1. System Description: 1.1 Size The raised access floor system shall consist of 600mm x 600mm x 3mm modular steel cement panels/ cementitious panels / cement filled
More informationDivision 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11
07 21 16 Blanket Insulation Page 1 of 11 Unifrax I LLC Design No. UNI/BI 120-14 FIRE RESISTANT GREASE DUCT FyreWrap Elite 1.5 Duct Insulation ASTM E 2336-16 and ICC-ES Acceptance Criteria for Grease Duct
More informationEASY RIDER (MUSTANG) EASY RIDER (PONY) EASY RIDER (ZEBRA) EASY RIDER (BRONCO)
Page 1 * IMPORTANT * PLEASE RETAIN THIS INSTRUCTION SHEET IN YOUR FILES. IT CONTAINS IMPORTANT REPLACEMENT PARTS INFORMATION. ALL EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THESE INSTRUCTIONS. IT
More informationHilti, Inc South 122 nd East Avenue Tulsa, OK
ttached are page(s) from the 2011 Hilti North merican Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation, corrosion,
More informationSAFEEND P4 WORKING DESCRIPTION INSTALLATION, REPAIRS AND MAINTENANCE. Doc. No.: SafeEnd P4 - Rev. A
SAFEEND P4 WORKING DESCRIPTION INSTALLATION, REPAIRS AND MAINTENANCE Doc. No.: SafeEnd P4 - Rev. A Working Description Prepared by: Fredrik Sangö Doc. no.: SafeEnd P4 Introduction/data: SafeEnd P4 is a
More informationAssembly instructions Mini Cheops Pyramid Art B to set into concrete
A Assembly instructions Mini Cheops Pyramid Art. 4643-1B to set into concrete \\Fileserver\text\PLAY\Play Installation Instructions\Installation Instructions 2012-2013\4643_1B-01-en-004.doc - 1 - Revision
More informationMaterials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.
Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon
More informationSECTION METAL STAIRS
SECTION 05 51 00 METAL STAIRS PART 1 GENERAL 1.1 SUMMARY A. Section includes steel stair frame of structural sections, with closed risers; pan to receive concrete fill stair treads and landings; integral
More informationSECTION METAL ATHLETIC LOCKERS
SECTION 10 51 13 - METAL ATHLETIC LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified
More informationTHOMAS. Buffalo Saddles. Tap In Products PIPE PRODUCTS. Universal Live Tap In Saddles for All Rigid Pipe Materials.
THOMAS PIPE PRODUCTS Tap In Products Buffalo Saddles Universal Live Tap In Saddles for All Rigid Pipe Materials A1 TAP IN PRODUCTS KITWE VALLEY - Copper Belt Province - Zambia PROJECT Kitwe Valley Pivot
More informationCode Compliance Research Report CCRR-0223
Code Compliance Research Report CCRR-0223 Issued: 06-30-2015 Renewal Due: 06-30-2018 Revised: 12-20-2017 DIVISION: 05 50 00 - Metal Fabrications Section: 05 52 00 - Metal Railings REPORT HOLDER: Ultra
More informationSOUTHEASTERN PENNSYLVANIA TRANSPORTATION AUTHORITY 1234 MARKET STREET, PHILADELPHIA, PA 19107
SOUTHEASTERN PENNSYLVANIA TRANSPORTATION AUTHORITY 1234 MARKET STREET, PHILADELPHIA, PA 19107 SPECIFICATION FOR PLATFORM RUBBING EDGE ASSEMBLIES FOR 69 TH ST TC, 40 TH ST, 34 TH ST, 2 ND ST, SPRING GARDEN
More informationKind of document : Assembly manual
Stalprodukt S.A. Kind of document : Assembly manual Reference No: IM/MD-41/16 Title : ASSEMBLY MANUAL OF ROAD SAFETY BARRIER StalPro Rail s4 according to EN 1317-5:2007+A1:2008 Page: 1 Issue No:V Pages:
More informationB. Polyethylene samples shall be submitted for Owner approval of color and quality.
Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and
More informationKeuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.
SECTION 05 73 16 {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes. PART 1 GENERAL 1.1 SUMMARY A. Section includes cable railing system, with architectural metal
More informationSECTION METAL ATHLETIC LOCKERS
SECTION 10 51 13 - METAL ATHLETIC LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified
More information150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS
ULEB 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS
More informationThink Safety, Think Safesite O&M - KEEGUARD
Think Safety, Think Safesite O&M - KEEGUARD Safesite Guardrail Systems SAFESITE GUARDRAIL SYSTEMS Safesite s guardrail systems including System 2000 and KeeGuard have been designed specifically to provide
More informationBOURNEMOUTH planter. Street Design Limited Unit 35 Hayhill Industrial Estate Barrow upon Soar Leicestershire LE12 8LD
UK street furniture designers & manufacturers BOURNEMOUTH planter As UK based, designers and manufacturers, Street Design can manufacture and supply the Bournemouth circular all metal planters, to suit
More informationCompany Directive ENGINEERING SPECIFICATION EE SPEC : 20/4. Relating to Substation Security Fences
Company Directive ENGINEERING SPECIFICATION EE SPEC : 20/4 Relating to Substation Security Fences Policy Summary This Specification sets out installation requirements and specifications for substation
More informationSpecification for Road Works Series Road Restraints Systems (Vehicle and Pedestrian)
Specification for Road Works Series 400 - Road Restraints Systems (Vehicle and Pedestrian) CC-SPW-00400 November 2015 CC Construction & Commissioning Standards TRANSPORT INFRASTRUCTURE IRELAND (TII) PUBLICATIONS
More informationA EN ROUND STORAGE SILO. Ø480cm, Ø560cm, Ø640cm, Ø720cm ASSEMBLY AND USER MANUAL. ARSKAMETALLI LTD
A70-1001-EN-201805 ROUND STORAGE SILO Ø480cm, Ø560cm, Ø640cm, Ø720cm ASSEMBLY AND USER MANUAL ARSKAMETALLI LTD www.arskametalli.fi CONTENTS Introduction Delivery information EU Declaration of Conformity
More informationSpecification for Road Works Series Road Restraints Systems (Vehicle and Pedestrian)
Specification for Road Works Series 400 - Road Restraints Systems (Vehicle and Pedestrian) CC-SPW-00400 March 2013 CC Construction & Commissioning Standards TRANSPORT INFRASTRUCTURE IRELAND (TII) PUBLICATIONS
More informationDuct Wrap Flexible Wraps
Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone
More informationJacksons Fencing T: E:
Manufacturer:. Web: www.jacksons-security.co.uk. Tel: +44 (0)1233 750393. Product Reference: Bow Top Service Life of Fencing All Jacksons steel fencing and gates are designed and manufactured to be fit
More informationFeatures Advantages Benefits
What is BoxBolt? A KEE SAFETY PRODUCT BoxBolt Guide - Eurocode 3 / DIN 18800 BOXBOLT is a fully tested and approved blind fixing solution for connecting to hollow section steelwork or where access is restricted
More informationRadiant PV-Solar Tripod System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT
Radiant PV-Solar Tripod System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT 2-2012 The PV-Solar Tripod System has been developed as a universal system for tilt solar panel roof-mounting
More informationKind of document : Assembly manual
Stalprodukt S.A. Kind of document : Assembly manual Reference No: IM/MD-39/16 Title : ASSEMBLY MANUAL OF DOUBLE SIDE SAFETY BARRIER StalPro Rail d according to EN 1317-5:2007+A2:2012 Page: 1 Issue No:VI
More informationCONSTRUCTION SPECIFICATION FOR GUIDE RAIL ENERGY ABSORBING TERMINALS
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 554 NOVEMBER 1989 CONSTRUCTION SPECIFICATION FOR GUIDE RAIL ENERGY ABSORBING TERMINALS 554.01 SCOPE 554.02 REFERENCES 554.05 MATERIALS 554.05.01 Concrete.02
More informationFD Damper Installation, Operating and Maintenance Instructions
FD Damper Installation, Operating and Maintenance Instructions 1 Health and Safety 1.1 Only competent personnel may carry out the work outlined within this document. 1.2 The wearing of appropriate Personal
More informationConcrete Inserts. B Adjustable Metal Deck Ceiling Bolt
B3019 - Adjustable Metal Deck Ceiling Bolt Size Range: 3 /8"-16 thru 3 /4"-10 rod Function: For use in metal deck formed concrete to attach hanger rods. Allows for pre-positioning of hanger rods in poured
More informationRacking Solutions for Timber Framed Buildings T-RS-UK Edition. +44 (0)
Racking Solutions for Timber Framed Buildings T-RS-UK 2014 Edition +44 (0) 1827 255 600 www.strongtie.co.uk Racking Solutions for Timber Framed Buildings About Simpson Strong-Tie For more than 50 years
More informationCPM Concrete Drainage Systems
CPM Group Ltd offer a complete range of precast concrete manhole units from DN 900 to DN 4000 in varying depths with tongue and groove joints. A djusting units Ductile iron cover & frame Cover slab DN1200
More informationCI/SfB (90.3) Jh2 January 2010 C L D. CLD Fencing Systems Specifier Guide
CI/SfB (90.3) Jh2 January 2010 C L D CLD Fencing Systems Specifier Guide 2 Introduction Introduction 3 Aesthetic boundary protection Full sports pitch systems CLD specialise in: rigid mesh fencing systems
More information