S T R U C T U R. Practical Solutions. magazine. Supplemental Damping and Using Tuned Sloshing Dampers. Tuned Sloshing Dampers

Size: px
Start display at page:

Download "S T R U C T U R. Practical Solutions. magazine. Supplemental Damping and Using Tuned Sloshing Dampers. Tuned Sloshing Dampers"

Transcription

1 Practical Solutions solutions for the practicing structural engineer Supplemental Damping and Using Tuned Sloshing Dampers By Jamieson K. Robinson P.Eng., Scott L. Gamble P.Eng., and Bujar M. Myslimaj Ph.D., P.Eng. Dynamic Loading and Structural Performance We tend to think of the structures that we build as solid immovable objects. Much of the standard design approach is based on the application of equivalent static load distributions, which reinforces this notion. However, buildings, bridges, spires, roofs, and other slender or flexible structures move when subjected to environmental forces like wind and earthquakes, or moving loads like cars and pedestrians in the case of bridges. Under certain conditions, these motions can cause undesirable increases in structural loads due to the inertia of the large masses involved, and occupant motion sensitivity, motion sickness, or fatigue of the structural materials used. A significant effort is typically expended by the project design team to select and optimize a structural and architectural scheme that is functional, and costefficient. For dynamically sensitive structures, the results of this effort (in terms of structural dynamic performance) can be highly dependant upon the initial assumption about the inherent (natural) damping in the structure. This energy absorption and dissipation characteristic is key to reducing dynamic effects as it increases the structure s ability to absorb the energy imparted to it from external excitations. Damping of real structures is generally expressed as a ratio to critical damping, the energy absorption value which would cause the structure to simply return to center without oscillating if pulled to one side and released. A dynamically-sensitive structure is defined by the National Building Code of Canada (NBCC) 2, to be higher than 12 meters, or having a height/ width ratio of 4 or greater, or being susceptible to vibrations. ASCE 7 code is not as specific as NBCC 2 to define these parameters. ASCE 7 does however recognize that dynamic effects for irregular-shaped buildings or those prone to complex wind loads must be accounted for by using analytical procedures and/or wind tunnel testing. Many engineers refer to the procedures outlined in NBCC 2, as this code is regarded as a leading reference for wind-induced loading. In common structural design practice, the inherent damping value is chosen based on average values recommended in technical literature, codes, and standards, for steel, concrete or composite structural systems. These values typically are assumed to be in the range of 1% to 2% of critical for buildings, and less for simpler structures. However, since each structure is unique, the actual inherent damping exhibited by the finished structure is also unique due to specific architectural and structural system layout, structural detailing and cladding. Changes of only.% of critical or less in the assumed level of damping can have a significant impact on wind-induced loads and motions of a structure. One proven way to achieve a specific overall damping level is to incorporate a Supplemental Damping System (SDS) into the structure. Over the past few years, there has been a noticeable increase in the implementation of supplementary damping in various types of structures such as buildings, bridges, spires, floors, roofs, and grandstands. An SDS is essentially a supplemental energy dissipation system that is optimally designed to absorb vibration energy from a structure, thereby reducing energy dissipation demand on the structure. There are many ways to add energy absorption to a structural system. Technologies in common use today can be broadly classed as distributed, impact, active mass, semi-active mass, mechanical passive tuned mass, and liquid-based passive tuned mass. The trend has been to use passive damping systems, as these systems need no control electronics or powered drive mechanisms and can be counted on to absorb energy when needed most, even during storms when power outages are most likely to occur. The remainder of this article will focus on the application of one passive SDS technology to high-rise buildings. Liquid tuned mass dampers typically have one of two forms, Tuned Liquid Column Dampers (TLCD) or Tuned Sloshing Dampers (). The focus will be on Tuned Sloshing Dampers due to their attractive qualities of simplicity, low cost and dependability with little or no maintenance. Tuned Sloshing Dampers A Tuned Sloshing Damper () is an example of an SDS that utilizes liquid waves to absorb energy from vibrating structures through wave travel and viscous action in a partially filled tank of liquid. The tank is designed so that the liquid surface wave has a frequency tuned to be near the fundamental frequency of the building. The frequency of the liquid is determined by the density, length, width and depth of the liquid. Figure 1: How it works June 27

2 Sloshing frequency (Hz) Liquid depth (m) Figure 1 depicts the basic principle of the fluid motion in the : Frame 1: Wind event not started. Structure not moving. Fluid at rest position. Frames 2 to 4: Wind event starts. Structure begins to oscillate due to wind. Wave in fluid moves in opposite direction of structure due to fluid inertia from gravity. Fluid motion is damped due to turbulence caused by flow restrictions (screens, posts, or louvers). Oscillation of structure is reduced. This cycle repeats for the duration of the wind event. Frame : Wind event completed. When the structure begins to move under wind forces, the liquid resonates out of phase with the structure and energy is dissipated from the liquid by flow-damping devices such as screens, louvers, or posts in the tank that resist the wave action. Different shapes of tanks, such as rectangular or circular, can be used in implementations to achieve certain goals. A rectangular tank can be tuned to two different frequencies in two orthogonal directions. Implementing Tuned Sloshing Dampers Design and Performance Testing The process for implementing an SDS into a building design is one where the Structural Motion Consultant, who has the expertise and experience to ensure optimum SDS performance, works closely with the design team to help balance energy absorption goals with structural performance and architectural design goals. Examples of this process are 3m 4m m 6m 7m 8m 9m 1m 11m Characteristic length of tank Minimum Water Depth Figure 2: A design chart indicating the minimal water depth (for a range of tank depths and sloshing frequencies) below which the liquid behavior will become highly non-linear. Elevation (floor) Y presented for two residential building projects (each between and 6 stories tall) currently under construction in New York City. For these projects, additional damping was deemed more effective and beneficial than traditional methods of increasing mass and/or stiffness to reduce building motions to acceptable levels for serviceability. At the early design stage of the building, a technology feasibility study identified that water tank s were most suitable for the projects since adequate floor space could be made available at the top of the building. Initially, the space requirement was based on simplified analysis to allow the engineer and architect to reserve adequate space. A number of possible configurations were investigated, including both deep tank and shallow tank types. The decision regarding the optimal type and size of was made based upon weighting the relative importance of space availability for the on the mechanical floor, performance targets (in terms of reduction of building motions), construction costs, and the immediate and longer term cost benefits of minimizing structure while maintaining building motion serviceability targets. As the projects progressed into Detailed Design and Construction Documents, more comprehensive time-domain simulations of building and motions and scale models of the tanks were developed and tested to fine-tune the damper and to ensure optimal performance at the specified return period. continued on next page -Year Wind Response with TLCDs, 22 deg X axis Y axis X TLCD COM Y TLCD COM -.. X Force (MN) Force (kn) Force (kn) X Shear Y Shear Floor 6 X Floor 6 Y X TLCD COM Y TLCD COM X TLCD, X axis Y TLCD, Y axis X TLCD, X axis Y TLCD, Y axis Time (s) Figure 3: Time-domain simulation animation graphics output. Using the wind tunnel test data for the project provided by the wind tunnel consultant as an input, analytical simulations investigate the performance of the damping system for the 1-year, -year, 1-year, and -year return wind storms. 1 June 27

3 Time Domain Analysis Simulations As wind action fluctuates with time, so does the behavior of the structure. The time domain simulations are an important part of the design process, since wind forces, building responses, and damping system motions are not constant with time. Referring to the chart in Figure 2 (see page 1), the red line indicates a threshold, below which the liquid behavior in a can become highly non-linear. It is important to account for the non-linear behavior of the during the design stage by using advanced time domain analysis techniques. Figure 4: Single-Axis Scale Model Performance Test: For fine-tuning design parameters; ensuring maximum possible damping is achieved in one direction. Time domain simulations are performed predicting the actual non-linear interaction between the moving structure under fluctuating wind loads and the moving mass (the sloshing water) in the damping system. Using the wind tunnel test data for the project provided by the wind tunnel consultant as an input, analytical simulations were used to investigate the performance of Tuned Sloshing Damper for the 1-year, -year, 1- year, and -year return wind storms. This ensured that the peak loads on the tank walls and screens, as well as peak water wave amplitudes and damping levels were accurately predicted for design purposes. This approach can also be used to predict the Ultimate State Design loading for the damper/structure interface where non-linearity at higher excitation levels requires better assessment of appropriate load factors. This makes sense when considering that the has several hundred tons of moving mass positioned at the top of the building. Visual animation-style time domain a- nalysis results can be provided. These graphics are often helpful to the design team to visualize and understand the building time response and damping system action. Figure 3 (see page 1) is from a project where such animations were provided. Figure : Dual-Axis Scale Model Shake-Table Performance Test: For fine-tuning design parameters; ensuring maximum possible damping is achieved in two directions simultaneously. Scale Model Performance Tests As the New York projects progressed into Detailed Design and Construction Documents, scale models of the tanks were developed and tested to fine-tune the damper and to ensure optimal performance at the specified return period. The tests were performed on a shaketable that simulated the wind-induced motions of the structures in which the s were to be installed. Figures 4 and show scale models test for two types of s. Figure 4 is for a singleaxis. This type of is designed so that the sloshing action of the liquid is tuned in only one direction, so that effective supplementary damping can enhance building performance for a singular direction of motion. This is useful when building responses acting in one principal direction are the highest contributor to overall building motions. In this case, the used static screen elements installed within the moving water to generate turbulence, and thus a means for energy dissipation (damping) within the. Figure is of a dual-axis scale model. In contrast to the one-directional, the dual-axis can enhance the damping performance in two directions simultaneously. Full Scale Model Scale 1:9 Parameter Imperial Metric Imperial Metric Length (L v ) ft 8. m ft.889 m Width (L x ) ft 7.67 m 2.76 ft.78 m Nominal Water Depth 3.2 ft.93 m.339 ft.13 m Tank Depth 14. ft m 1.6 ft.474 m Nominal fy Frequency.18 Hz.18 Hz.6 Hz.6 Hz Nominal fx Frequency.28 Hz.28 Hz.62 Hz.62 Hz Upper Sweep Frequency.344 Hz.344 Hz 1.31 Hz 1.31 Hz Lower Sweep Frequency.83 Hz.83 Hz.2 Hz.2 Hz Minimum Floor/ Table Amplitude Maximum Floor/ Table Amplitude Low Frequency Low Amplitude Peak Force Low Frequency Low Amplitude Peak Force Summary of Test Parameters: Full-Scale and Model-Scale In geographic regions where seismic design is also required, the time domain simulations using earthquake ground motions are used to check the performance of damping system and to determine the loading produced between the and the structure. For this purpose, many modes of structural vibration need to be examined. The bi-directional on this project used cruciform-shaped, static posts suspended into the moving water as the means to generate turbulence, and thus energy dissipation (damping)..7 ft.23 m.8 ft.3 m.86 ft.246 m.9 ft.27 m 481 lbf 218 N 7 lbf 3 N 3282 lbf 1347 N 42 lbf 18 N Table 1: Test parameters comparing characteristics of a full-scale in the building to the model-scale tested in the laboratory. 16 June 27

4 Figure 6: Close-up view of scale model damping screens. Load cells are used to measure shear forces and drag loads on the screens from the moving waves. The shake-table test was arranged to impose horizontal motions on the scale model. The motions imposed on the were sinusoidal, with control over the amplitude and frequency of the oscillations. For the New York projects performed by Motioneering, the total full-scale mass of the s are about 17, kg or 19 tons (with a length of 13.7 meters and width of. meters) for one project, and about 66, kg or 73 tons (with a length of 8. meters and a width of 7.1 meters) for the other project. The model scale required for the shake-table tests was 1:9. This translated to a model dimension of 1. meters in the long-axis (primary testing) direction for one project and.9 meters in the long-axis for the other. The full-scale and model-scale test parameters are summarized in Table 1. The scale model was mounted on a platform suspended by four steel bars from a rigid frame. The purpose of these bars was to carry the vertical load of the tank, while the shear forces were measured with load cells at the joints between the frame and the platform. The vertical displacement of the fluid at the Figure 7: Constructing the atop a new 6 floor residential building in New York City. The tank walls were constructed with cast-in-place poured concrete, since the material and labor to install was easily obtainable. ADVERTISEMENT For Advertiser Information, visit end walls of the tank was recorded, as well as the horizontal displacement of the shake-table to verify the input. The horizontal accelerations of the shake-table were also recorded. Each test consisted of a frequency sweep, where lower and upper bounds, the amplitude of excitation, and number of cycles and time interval at each frequency were specified. At each frequency, the maximum vertical,. 17 June 27

5 displacement of the fluid surface at the end walls of the tank was recorded. The resulting maximum amplitude versus frequency plot was used to establish the natural frequency of the system (see Figure 6, page 17). The tests were an important part of the design process. Necessary information was obtained for the detailed design of the tank, such as hydrostatic and hydrodynamic forces on the tank walls and ceiling during serviceability and design wind events. The tests also Figure 8: Damping Screen installation inside a provided valuable information to: Tank. Screen geometry is designed for ease of fabrication (a) optimize the porosity of the and installation. screens that are used to create local flow damping and energy dissipation, (b) only means for water loss is through evaporation (which is minimal in an enclosed tank). refine the predictions of wave amplitudes that generate shear forces and screen drag loads, At the time of writing this article, and (c) optimize screen or vane selection. construction for the two residential projects This ensured that the design of the tank and in New York was ongoing. Figures 7 (page 17), screens was safe and the performance objectives were 8 and 9 show some of the construction work. achieved. Construction The General Contractor team performed construction of the s. The tank walls were constructed with cast-in-place poured concrete, since the material and labor to install was easily obtainable. A waterproofing membrane was used to seal the tank walls. Since the top of the tank is usually dry, the damping louvers or screens were anchored to the tank roof and suspended into the water in the tank. Automatic water level monitoring was provided using a standard float-type sensor and water supply make-up solenoid valve. The need for water level replenishment is generally infrequent, since the Figure 9: Damping Screens are fastened to the tank roof, avoiding piercing of the waterproofing membrane. Commissioning Once the construction of the s is completed and the site is ready for commissioning, then final building motions (using accelerometers) are measured using our portable data acquisition equipment. The fundamental building frequencies are determined using FFT analysis of the acceleration data. Final adjustment of the water level is performed to tune the tank to the optimal frequency, thus matching the building frequencies for best possible damping performance. As with any building system, periodic visual inspections are recommended as part of a routine maintenance plan. Summary A range of different types of Supplementary Damping Systems (SDS) can be used to enhance the damping capabilities of a structure. This article has focused upon the design and implementation of one type of passive damping system the Tuned Sloshing Damper (). These types of damping systems are an effective means to reduce dynamic effects by increasing the structure s ability to absorb the energy imparted to it from external excitations. A is an efficient SDS option for structures with a moderate need for additional damping. For a typical mid-rise to high-rise structure, total effective damping levels of 3% to 4% of critical can often be achieved. s are attractive due to their qualities of simplicity, low cost and dependability with little or no maintenance. Other alternative and very effective damping options also exist, some of which will be discussed in future articles in. Scott Gamble, P.Eng., joined Motioneering in 24 as Vice President. Before coming to Motioneering, Scott gained 23 years of experience with Motioneering s sister company, RWDI, providing consulting services for clients. Mr. Gamble was awarded the Gzowski Gold Medal for Best Technical Paper, 199 by the Canadian Journal of Civil Engineering, and has contributed to the National Building Code of Canada provisions for snow loading of large roofs and arched roofs. He can be reached via at scott.gamble@motioneering.ca. Jamieson K. Robinson, P.Eng., is a Senior Specialist for Business Development and Project Management for Motioneering and RWDI. His experience has taken him through managing many of the major damping system design and implementation projects for the firm. He can be reached via at jamieson.robinson@motioneering.ca. Bujar Myslimaj, Ph.D., P.Eng., is a Senior Specialist at RWDI Inc., Guelph, Ontario, Canada. His experience includes research and consulting in earthquake engineering, nonlinear response of structures, windinduced loading and structural response control. He published and presented several research and technical papers in European, Japanese and International journals and conferences. He can be reached via at bujar.myslimaj@rwdi.com. 18 June 27

Vibration Control by Tuned Liquid Dampers

Vibration Control by Tuned Liquid Dampers Vibration Control by Tuned Liquid Dampers Motive Construction of tall structures in regions around the world where earthquakes and extreme-wind conditions take place have been a concern to structural engineers.

More information

Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings

Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings Abstract R.J. McNamara, SE McNamara / Salvia Inc. 160 Federal Street, 16 th Floor Boston, MA 02110 +1 617 737 0040 Douglas P. Taylor,

More information

Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper

Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper Namrata Yannawar (P.G. Student, Department of Civil Engineering, Rajashri Shahu College of Engineering, Pune, India) Abstract: Earthquake

More information

BUILDING MOTION CONTROL: SUPPLEMENTARY DAMPING SYSTEMS FOR TALL & SLENDER BUILDINGS

BUILDING MOTION CONTROL: SUPPLEMENTARY DAMPING SYSTEMS FOR TALL & SLENDER BUILDINGS BUILDING MOTION CONTROL: SUPPLEMENTARY DAMPING SYSTEMS FOR TALL & SLENDER BUILDINGS Sudeesh Kala, M.A.Sc., B.E. (Hons), P.Eng. Regional Manager Associate Rowan Williams Davies & Irwin Inc. (RWDI) RWDI

More information

Seismic Behavior Of Reinforced Concrete Buildings Under Varying Frequency Contents

Seismic Behavior Of Reinforced Concrete Buildings Under Varying Frequency Contents Volume-5, Issue-3, June-2015 International Journal of Engineering and Management Research Page Number: 405-410 Seismic Behavior Of Reinforced Concrete Buildings Under Varying Frequency Contents Mr. Suryakant

More information

Response Behaviour of a Three Storied Framed Structure with Tuned Liquid Damper

Response Behaviour of a Three Storied Framed Structure with Tuned Liquid Damper Response Behaviour of a Three Storied Framed Structure with Tuned Liquid Damper Namrata Yannawar 1, G.R.Patil 2 P.G. Student, Department of Civil Engineering, Rajashri Shahu College of Engineering, Pune,

More information

Parametric Studies on Tuned Liquid Damper by Horizontal Shake Table Experiments

Parametric Studies on Tuned Liquid Damper by Horizontal Shake Table Experiments IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 12, Issue 5 Ver. V (Sep. - Oct. 2015), PP 41-47 www.iosrjournals.org Parametric Studies on Tuned

More information

Torsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings

Torsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings Torsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings Ramya S R 1, Dr. P M Ravindra 2 1M. Tech Student, Department of Civil Engineering, Bangalore Institute of Technology, Bengaluru-

More information

Recent Applications of Damping Systems for Wind Response

Recent Applications of Damping Systems for Wind Response ctbuh.org/papers Title: Authors: Subject: Keywords: Recent Applications of Damping Systems for Wind Response Peter Irwin, RWDI Brian Breukelman, RWDI Wind Engineering Damping Wind Loads Publication Date:

More information

SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES

SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES G.S. Balakrishna 1, Jini Jacob 2 1 (Department of Civil Engineering, SSET/ M G University, India) 2 (Department of Civil

More information

Experimental Study on the Outrigger Damping System for High-Rise Building

Experimental Study on the Outrigger Damping System for High-Rise Building Experimental Study on the Outrigger Damping System for High-Rise Building P. Tan, C.J. Fang, W.R. Tu & F.L. Zhou Guangzhou University, China Y. Wang & M. Jiang Ove Arup & Partners Ltd Shenzhen Branch,

More information

SUPPLEMENTARY DAMPING SYSTEMS

SUPPLEMENTARY DAMPING SYSTEMS Improving occupant comfort by enhancing a structure s dynamic response to externally induced motion When a structure is subjected to external forces wind, pedestrian movement or seismic activity, for example

More information

Wind Tunnel Applications for Buildings

Wind Tunnel Applications for Buildings Wind Tunnel Applications for Buildings Presented by: Jim Swanson, Halvorson and Partners Donald Scott, PCS Structural Solutions Jon Galsworthy, RWDI Add Company Logo Here Outline 1. Introduction 2. ASCE7

More information

SEISMIC DESIGN OF STRUCTURE

SEISMIC DESIGN OF STRUCTURE SEISMIC DESIGN OF STRUCTURE PART I TERMINOLOGY EXPLANATION Chapter 1 Earthquake Faults Epicenter Focal Depth Focus Focal Distance Epicenter Distance Tectonic Earthquake Volcanic Earthquake Collapse Earthquake

More information

Studies on the Application of Tuned Liquid Dampers (TLD) to Up-Grade the Seismic Resistance of Structures

Studies on the Application of Tuned Liquid Dampers (TLD) to Up-Grade the Seismic Resistance of Structures Studies on the Application of Tuned Liquid Dampers (TLD) to Up-Grade the Seismic Resistance of Structures By A. A. El Damatty, Ph.D., P. Eng. Assistant Professor Department of Civil and Environmental Engineering

More information

Effectiveness of Tuned Liquid Column Dampers on Vibration Behavior of One-story Steel Structure under Harmonic Force and an Earthquake Record

Effectiveness of Tuned Liquid Column Dampers on Vibration Behavior of One-story Steel Structure under Harmonic Force and an Earthquake Record Australian Journal of Basic and Applied Sciences, 6(13): 41-47, 2012 ISSN 1991-8178 Effectiveness of Tuned Liquid Column Dampers on Vibration Behavior of One-story Steel Structure under Harmonic Force

More information

THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING

THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 3457 THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING

More information

An Experimental Investigation on Dynamic Response Control of Structures using Tuned Liquid Column Damper

An Experimental Investigation on Dynamic Response Control of Structures using Tuned Liquid Column Damper An Experimental Investigation on Dynamic Response Control of Structures using Tuned Liquid Column Damper Supradip Saha a, Rama Debbarma b, Member, ASCE a- M.Tech Scholar, b- Associate Professor Department

More information

Wind Tunnel Applications for Buildings

Wind Tunnel Applications for Buildings Wind Tunnel Applications for Buildings Presented by: Jim Swanson, Halvorson and Partners Donald Scott, PCS Structural Solutions Jon Galsworthy, RWDI Add Company Logo Here Outline 1. Introduction 2. ASCE7

More information

Tuned Liquid Sloshing Water Damper: A Robust Device for Seismic Retrofitting

Tuned Liquid Sloshing Water Damper: A Robust Device for Seismic Retrofitting Tuned Liquid Sloshing Water Damper: A Robust Device for Seismic Retrofitting Nishant Kishore Rai 1, G. R. Reddy 2 and V. Venkatraj 3 1,3 Directorate of Construction Services and Estate Management, Department

More information

0306 SEISMIC LOADS GENERAL

0306 SEISMIC LOADS GENERAL 0306 SEISMIC LOADS 0306.1 GENERAL Every structure, and portion thereof, including nonstructural components such as architectural, mechanical, and electrical components, shall be designed and constructed

More information

Analysis of a Multi-Tower Frame Structure connected at different levels using ETABS

Analysis of a Multi-Tower Frame Structure connected at different levels using ETABS Analysis of a Multi-Tower Frame Structure connected at different levels using ETABS RISHABH SISODIA 1, N. Tej Kiran 2, K. Sai Sekhar Reddy 3 1Student, Dept. of Structural and Geotechnical Engineering,

More information

DYNAMIC TESTING OF FULL-SCALE 11-STORY RC BUILDING AND ITS 3-STORY STRUCTURAL PART: COMPARISON OF THE RESULTS AND SEISMIC RESISTANCE ESTIMATION

DYNAMIC TESTING OF FULL-SCALE 11-STORY RC BUILDING AND ITS 3-STORY STRUCTURAL PART: COMPARISON OF THE RESULTS AND SEISMIC RESISTANCE ESTIMATION DYNAMIC TESTING OF FULL-SCALE 11-STORY RC BUILDING AND ITS 3-STORY STRUCTURAL PART: COMPARISON OF THE RESULTS AND SEISMIC RESISTANCE ESTIMATION ABSTRACT : I. Iskhakov and Y. Ribakov Dept. of Civil Engineering,

More information

R. J. McNamara, S.E.

R. J. McNamara, S.E. USE OF MOTION AMPLIFICATION DEVICES AND FLUID DAMPERS TO REDUCE THE WIND INDUCED RESPONSE OF TALL BUILDINGS by R. J. McNamara, S.E. McNamara/Salvia, Inc. Boston, MA 02110 USE OF MOTION AMPLIFICATION DEVICES

More information

The Effect of Frame Geometry on the Seismic Response of Self-Centering Concentrically- Braced Frames

The Effect of Frame Geometry on the Seismic Response of Self-Centering Concentrically- Braced Frames International Journal of Civil and Environmental Engineering 6 212 The Effect of Frame Geometry on the Seismic Response of Self-Centering Concentrically- Braced Frames David A. Roke and M. R. Hasan Abstract

More information

Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting

Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting Selection of Structural systems Load paths Materials Approximate sizing of members Primary mechanisms

More information

OPTIMUM DAMPING IN ISOLATION SYSTEM

OPTIMUM DAMPING IN ISOLATION SYSTEM 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 1919 OPTIMUM DAMPING IN ISOLATION SYSTEM Shashi K. THAKKAR 1 and Sarvesh K. JAIN 2 SUMMARY Base isolation

More information

S. Gandhi *1, Syed Rizwan 2

S. Gandhi *1, Syed Rizwan 2 2017 IJSRSET Volume 3 Issue 3 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Analysis and Design of Tall Building (G+21) Using ETABS S. Gandhi *1, Syed Rizwan

More information

RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING

RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING Asha Joseph 1 and Glory Joseph 2 1 Research Scholar, Cochin University of Science and Technology, Kerala 2 Associate Professor, Cochin

More information

Study of seismic effect on buildings modified with shear wall

Study of seismic effect on buildings modified with shear wall Study of seismic effect on buildings modified with shear wall Hingkam Dada, Zuhail Bin Basheer T.P,Bullo Apo, Shaheel Ahammed 1234B.Tech Student, Civil Engineering, Mar Athanasius college of engineeringe,kerala,

More information

Department of Civil Engineering, SKP Engg. College, Tiruvanamalai, TN, India

Department of Civil Engineering, SKP Engg. College, Tiruvanamalai, TN, India DESIGN AND ANALYSIS OF MULTI- STOREYED BUILDING UNDER STATIC AND DYNAMIC LOADING CONDITIONS USING ETABS Balaji.U. A 1, Mr. Selvarasan M.E. B 2 1 PG Student, 2 Asst.Professor Department of Civil Engineering,

More information

Vibration control of a building model with base isolation

Vibration control of a building model with base isolation Proceedings of th International Congress on Acoustics, ICA -7 August, Sydney, Australia Vibration control of a building model with base isolation Helen Wu School of Engineering, Edith Cowan University,

More information

Seismic Evaluation of the Historic East-Memorial Building Retrofitted with Friction Dampers, Ottawa, Canada

Seismic Evaluation of the Historic East-Memorial Building Retrofitted with Friction Dampers, Ottawa, Canada Seismic Evaluation of the Historic East-Memorial Building Retrofitted with Friction Dampers, Ottawa, Canada S. Jabbour & D.J. Carson Parsons Brinckerhoff Halsall Inc. SUMMARY: A seismic evaluation under

More information

Introduction of an innovative base isolation system for seismic protection of HV components based on a combination of wire ropes and viscous dampers

Introduction of an innovative base isolation system for seismic protection of HV components based on a combination of wire ropes and viscous dampers Earthquake Resistant Engineering Structures X 147 Introduction of an innovative base isolation system for seismic protection of HV components based on a combination of wire ropes and viscous dampers M.

More information

Dynamic optimization for the wind-induced response of a tall building

Dynamic optimization for the wind-induced response of a tall building Dynamic optimization for the wind-induced response of a tall building Workamaw Warsido 1, Ryan Merrick 2 Girma Bitsuamalk 3, 1 Research Assistant, Civil and Environmental Engineering department (CEE),

More information

DESIGN OF OPTIMUM PARAMETERS OF TUNED MASS DAMPER FOR A G+8 STORY RESIDENTIAL BUILDING

DESIGN OF OPTIMUM PARAMETERS OF TUNED MASS DAMPER FOR A G+8 STORY RESIDENTIAL BUILDING International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 5 Issue: 11 Nov 218 www.irjet.net p-issn: 2395-72 DESIGN OF OPTIMUM PARAMETERS OF TUNED MASS DAMPER FOR A G+8

More information

Application of Isolation Technology in High-voltage Electrical Equipments

Application of Isolation Technology in High-voltage Electrical Equipments Application of Isolation Technology in High-voltage Electrical Equipments WEN Bo 1 AND ZHANG Jun-fa 2, NIU Di-tao 3 1 Doctoral Candidate, Dept. of Civil Engineering, Xi an University of Architecture &

More information

"Impact of New IS 1893 & Related Codes on Design of tall Buildings, Including Trend Setting Structures

Impact of New IS 1893 & Related Codes on Design of tall Buildings, Including Trend Setting Structures "Impact of New IS 1893 & Related Codes on Design of tall Buildings, Including Trend Setting Structures Conference on Planning and Design of Tall Buildings including Earthquake and Wind Effects By S. C.

More information

Seismic Performance of Combined Isolation System for Asymmetric Buildings Using Non- Linear Time History Analysis

Seismic Performance of Combined Isolation System for Asymmetric Buildings Using Non- Linear Time History Analysis ISSN(Online): 9-87 Seismic Performance of Combined Isolation System for Asymmetric Buildings Using Non- Linear Time History Analysis Manoj U. Deosarkar, S. D. Gowardhan M.Tech (Structural Engineering)

More information

FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES

FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES Hirokazu IEMURA 1, Akira IGARASHI 2, Torajiro FUJIWARA 3 And Akihiro TOYOOKA 4 SUMMARY In order to verify the

More information

ACCURATE LINEAR AND NONLINEAR SEISMIC SSI ANALYSIS BASED ON ANSYS FE MODELING USING EXTENDED SASSI METHODOLOGY

ACCURATE LINEAR AND NONLINEAR SEISMIC SSI ANALYSIS BASED ON ANSYS FE MODELING USING EXTENDED SASSI METHODOLOGY Transactions, SMiRT-24 II, Paper 468 ACCURATE LINEAR AND NONLINEAR SEISMIC SSI ANALYSIS BASED ON ANSYS FE MODELING USING EXTENDED SASSI METHODOLOGY Dan M. Ghiocel 1, Mike Saremi 2 1 Chief of Engineering

More information

Dynamic Stability of Elastomeric Bearings at Large Displacement

Dynamic Stability of Elastomeric Bearings at Large Displacement Dynamic Stability of Elastomeric Bearings at Large Displacement A. Masroor, J. Sanchez, G. Mosqueda University at Buffalo, NY, USA K. L. Ryan University of Nevada, Reno, USA SUMMARY: Bearings used in the

More information

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer: Chapter II. REVIEW OF PREVIOUS RESEARCH II.1. Introduction: The purpose of this chapter is to review first the basic concepts for earthquake engineering. It is not intended to review the basic concepts

More information

Forced vibration testing of a thirteen storey concrete building

Forced vibration testing of a thirteen storey concrete building Forced vibration testing of a thirteen storey concrete building F. Shabbir, & P. Omenzetter Department of Civil and Environmental Engineering, University of Auckland, Auckland, New Zealand 2008 NZSEE Conference

More information

On the Vibration Mechanism of Historical Menar-Jonban Monument in Iran

On the Vibration Mechanism of Historical Menar-Jonban Monument in Iran On the Vibration Mechanism of Historical Menar-Jonban Monument in Iran Naghdali Hosseinzadeh Structural Engineering Research Center, International Institute of Earthquake Engineering and Seismology (IIEES),

More information

Research on seismic behavior of Wood-Concrete Hybrid Structure

Research on seismic behavior of Wood-Concrete Hybrid Structure Research on seismic behavior of Wood-Concrete Hybrid Structure ABSTRACT: Haibei Xiong 1 and Guocheng Jia 1 Associate Professor, College of Civil Engineering, Tongji University, Shanghai, China Master,

More information

AC : EXPERIMENTAL EXPLORATION OF COMMON MODEL- ING ASSUMPTIONS

AC : EXPERIMENTAL EXPLORATION OF COMMON MODEL- ING ASSUMPTIONS AC 2011-129: EXPERIMENTAL EXPLORATION OF COMMON MODEL- ING ASSUMPTIONS Cole C McDaniel, California Polytechnic State University Cole C. McDaniel, Ph.D., P.E. Associate Professor, Architectural Engineering

More information

MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING

MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 1443 MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING Jiandong ZHOU 1, Ming HU

More information

Nonlinear Dynamic Analysis a Step Advance

Nonlinear Dynamic Analysis a Step Advance Nonlinear Dynamic Analysis a Step Advance in Assessing the Vulnerability of Buildings Editor s note: The strength of an earthquake catastrophe model in producing to Earthquake reliable loss estimates lies

More information

PERIODS OF REINFORCED CONCRETE FRAMES DURING NONLINEAR EARTHQUAKE RESPONSE

PERIODS OF REINFORCED CONCRETE FRAMES DURING NONLINEAR EARTHQUAKE RESPONSE PERIODS OF REINFORCED CONCRETE FRAMES DURING NONLINEAR EARTHQUAKE RESPONSE Arthur C HEIDEBRECHT And Nove NAUMOSKI SUMMARY This paper presents the results of a detailed evaluation of the relationships between

More information

Chapter 13 SEISMICALLY ISOLATED STRUCTURE DESIGN REQUIREMENTS

Chapter 13 SEISMICALLY ISOLATED STRUCTURE DESIGN REQUIREMENTS Chapter 13 SEISMICALLY ISOLATE STRUCTURE ESIGN REQUIREMENTS 13.1 GENERAL 13.1.1 Scope. Every seismically isolated structure and every portion thereof shall be designed and constructed in accordance with

More information

CONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT

CONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT 17th U.S.-Japan-New Zealand Workshop on the Improvement of Structural Engineering and Resilience CONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT N.

More information

Seismic behavior of concrete structures equipped with ADAS devices

Seismic behavior of concrete structures equipped with ADAS devices Acta Technica 62 No. 4B/2017, 1 8 c 2017 Institute of Thermomechanics CAS, v.v.i. Seismic behavior of concrete structures equipped with ADAS devices Hassan Ghahremani Feshalenji 1 Abstract. The added damping

More information

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan Proposal Xiaodong Jiang Structure Option Advisor: Dr. Linda Hanagan December 12, 2014 Executive Summary Xyston Inn is a 17-story hotel building that will be located in Brooklyn, New York. The design of

More information

COMPUTER AIDED DESIGN AND ANALYSIS OF RC FRAME BUILDINGS SUBJECTED TO EARTHQUAKES

COMPUTER AIDED DESIGN AND ANALYSIS OF RC FRAME BUILDINGS SUBJECTED TO EARTHQUAKES COMPUTER AIDED DESIGN AND ANALYSIS OF RC FRAME BUILDINGS SUBJECTED TO EARTHQUAKES ABSTRACT O. El Kafrawy 1, M. Yousuf 1 and A. Bagchi 2 Computer use in structural analysis and design dates back a number

More information

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan Proposal Xiaodong Jiang Structure Option Advisor: Dr. Linda Hanagan December 12, 2014 Executive Summary Xyston Inn is a 17-story hotel building that will be located in Brooklyn, New York. The design of

More information

The influence of vertical seismic ground motion on structures with uplift

The influence of vertical seismic ground motion on structures with uplift The influence of vertical seismic ground motion on structures with uplift K.D. Makan, Y. Chen, T. Larkin & N. Chouw Department of Civil and Environmental Engineering, The University of Auckland, New Zealand.

More information

Concept of Earthquake Resistant Design

Concept of Earthquake Resistant Design Concept of Earthquake Resistant Design Sudhir K Jain Indian Institute of Technology Gandhinagar November 2012 1 Bhuj Earthquake of 2001 Magnitude 7.7, ~13,805 persons dead Peak ground acceleration ~0.60g

More information

Megacities Building Sway Considerations in Elevators Design for Mega Tall Buildings

Megacities Building Sway Considerations in Elevators Design for Mega Tall Buildings Megacities Building Sway Considerations in Elevators Design for Mega Tall Buildings Authors: Jaakko Kalliomäki, M.Sc., KONE Corporation Jarkko Saloranta, M. Sc., KONE Corporation / Upwind Authors Jaakko

More information

Seismic Analysis of Elevated Water Tank

Seismic Analysis of Elevated Water Tank Seismic Analysis of Elevated Water Tank Nishigandha R.Patil 1, Dr. R. S. Talikoti 2 1. PG Student, 2 Head Of Department, 1,2 Late G.N. Sapkal College Of Engineering Nashik, Savitribai Phule Pune University,

More information

TEMPERING. Tremors. San Bernardino s new courthouse features a comprehensive seismic design that minimizes life-cycle costs.

TEMPERING. Tremors. San Bernardino s new courthouse features a comprehensive seismic design that minimizes life-cycle costs. TEMPERING Tremors BY MARK SARKISIAN, S.E., P.E., PETER LEE, S.E., P.E., LINDSAY HU, P.E., AND ALVIN TSUI, S.E., P.E. San Bernardino s new courthouse features a comprehensive seismic design that minimizes

More information

Chinmoy Kolay Research Engineer

Chinmoy Kolay Research Engineer Chinmoy Kolay Research Engineer Hands-on exercises 1. Numerical simulations using HybridFEM to experience some features of HybridFEM 2. Real-time hybrid simulation (RTHS) of a steel building 3. Soil-structure

More information

Shaking table experimental study on the base isolation system made of polymer bearings

Shaking table experimental study on the base isolation system made of polymer bearings Shaking table experimental study on the base isolation system made of polymer bearings Tomasz Falborski, Robert Jankowski Gdansk University of Technology, Poland SUMMARY: Base isolation is one of the most

More information

Hybrid Shake Table for the Testing of Midlevel Seismic Isolation Systems

Hybrid Shake Table for the Testing of Midlevel Seismic Isolation Systems 3th World Conference on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures - commemorating JSSI th Anniversary - September -7 3 Sendai Japan Paper No. # 9 Hybrid Shake Table

More information

Seismic Rehabilitation of Selby Condominium Complex, Montreal (Quebec), Canada

Seismic Rehabilitation of Selby Condominium Complex, Montreal (Quebec), Canada Seismic Rehabilitation of Selby Condominium Complex, Montreal (Quebec), Canada M. Zarrabi & R. Bartosh BCA Consultants, Montreal, Quebec, Canada A. Pall Pall Dynamics Limited, Montreal, Canada SUMMARY

More information

Shake table test a structure retrofitted using 2-4 Direction Displacement Dependent (D3) viscous dampers

Shake table test a structure retrofitted using 2-4 Direction Displacement Dependent (D3) viscous dampers Shake table test a structure retrofitted using 2-4 Direction Displacement Dependent (D3) viscous dampers N.K. Hazaveh, A.A. Rad, G.W. Rodgers, J.G. Chase & S. Pampanin University of Canterbury, Christchurch.

More information

Pushover Analysis of Reinforced Concrete Structures with Coupled Shear Wall and Moment Frame. *Yungon Kim 1)

Pushover Analysis of Reinforced Concrete Structures with Coupled Shear Wall and Moment Frame. *Yungon Kim 1) Pushover Analysis of Reinforced Concrete Structures with Coupled Shear Wall and Moment Frame *Yungon Kim 1) 1) R&D Division, Hyundai Engineering and Construction, Yong-in 446-716, Korea 1) yungon.kim@hdec.co.kr

More information

CE 6071 Structural Dynamics and Earthquake Engineering UNIT -5 2 MARKS

CE 6071 Structural Dynamics and Earthquake Engineering UNIT -5 2 MARKS CE 6071 Structural Dynamics and Earthquake Engineering UNIT -5 2 MARKS 1. What is strong column weak beam design concept (N/D-16) The design philosophy for frames is to avoid failure of column from both

More information

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online): IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online): 2321-0613 Experimental Investigation of Effect of Tuned Mass Damper in the Structure using Shake

More information

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS By H.S. Lew 1 and Sashi K. Kunnath Presented at the rd Joint Meeting of the UJNR Panel on Wind and Seismic Effects ABSTRACT This

More information

Floating Type Isolation System Using Earthquake Early Warning

Floating Type Isolation System Using Earthquake Early Warning Floating Type Isolation System Using Earthquake Early Warning K. Minagawa Saitama Institute of Technology, Saitama S. Fujita Tokyo Denki University, Tokyo G. Tanaka Oiles Corporation, Tochigi H. Simosaka

More information

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance APPLIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS FALL 2013 lecture fifteen design for lateral loads Lateral Load Resistance stability important for any height basic mechanisms

More information

CHAPTER 3 IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF CUTTING TOOL SYSTEM USING VISCOELASTIC DAMPER

CHAPTER 3 IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF CUTTING TOOL SYSTEM USING VISCOELASTIC DAMPER 44 CHAPTER 3 IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF CUTTING TOOL SYSTEM USING VISCOELASTIC DAMPER This chapter introduces a novel design for turning tool holder assembly with enhanced damping capability.

More information

COMPARATIVE ANALYSIS OF SEISMIC ISOLATED SYSTEMS IN BRIDGES

COMPARATIVE ANALYSIS OF SEISMIC ISOLATED SYSTEMS IN BRIDGES COMPARATIVE ANALYSIS OF SEISMIC ISOLATED SYSTEMS IN BRIDGES APPLICATION TO A STUDY CASE João Tiago Ferreira Marques de Abreu Abstract This paper represents the resume of a study where is evaluated the

More information

WIND TUNNEL STUDIES AND THEIR VALIDATIONS WITH FIELD MEASUREMENTS FOR A SUPER-TALL BUILDING

WIND TUNNEL STUDIES AND THEIR VALIDATIONS WITH FIELD MEASUREMENTS FOR A SUPER-TALL BUILDING The Seventh Asia-Pacific Conference on Wind Engineering, November 8-12, 2009, Taipei, Taiwan WIND TUNNEL STUDIES AND THEIR VALIDATIONS WITH FIELD MEASUREMENTS FOR A SUPER-TALL BUILDING Q.S. Li 1, Jiming

More information

SEISMIC DESIGN CHARACTERISTICS OF THE NEW BUILDING FOR DIGITAL AUTOMATION EQUIPMENT FOR LOVIISA NUCLEAR POWER PLANT

SEISMIC DESIGN CHARACTERISTICS OF THE NEW BUILDING FOR DIGITAL AUTOMATION EQUIPMENT FOR LOVIISA NUCLEAR POWER PLANT 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 2803 SEISMIC DESIGN CHARACTERISTICS OF THE NEW BUILDING FOR DIGITAL AUTOMATION EQUIPMENT FOR LOVIISA

More information

STRUCTURAL DAMAGE DETECTION THROUGH FORCED VIBRATION TESTING

STRUCTURAL DAMAGE DETECTION THROUGH FORCED VIBRATION TESTING Paper N 0302 Registration Code: S-N1463289699 STRUCTURAL DAMAGE DETECTION THROUGH FORCED VIBRATION TESTING W. Rosenblatt (1), Dr. P. Laursen, P.E. (2), Dr. C. McDaniel, P.E. (3), Dr. G. Archer, P.Eng.

More information

Dynamic Analysis of Large Steel Tanks

Dynamic Analysis of Large Steel Tanks Transactions of the 17 th International Conference on Structural Mechanics in Reactor Technology (SMiRT 17) Prague, Czech Republic, August 17 22, 2003 Paper # K14-1 Dynamic Analysis of Large Steel Tanks

More information

Lecture 5 Building Irregularities

Lecture 5 Building Irregularities 1 Lecture 5 Building Irregularities Course Instructor: Dr. Carlos E. Ventura, P.Eng. Department of Civil Engineering The University of British Columbia ventura@civil.ubc.ca Short Course for CSCE Calgary

More information

An experimental study of structural plastic hinge development and nonlinear soil deformation

An experimental study of structural plastic hinge development and nonlinear soil deformation An experimental study of structural plastic hinge development and nonlinear soil deformation X. Qin 1 and N. Chouw 2 1. PhD student, Department of Civil and Environmental Engineering, The University of

More information

Title. Author(s)M. OHSAKI; S. TSUDA; N. SUGIYAMA. Issue Date Doc URL. Type. Note. File Information DIRECTIONAL SEISMIC VIBRATION CONTROL

Title. Author(s)M. OHSAKI; S. TSUDA; N. SUGIYAMA. Issue Date Doc URL. Type. Note. File Information DIRECTIONAL SEISMIC VIBRATION CONTROL Title PARAMETER OPTIMIZATION OF GEOMETRICALLY NONLINEAR TU DIRECTIONAL SEISMIC VIBRATION CONTROL Author(s)M. OHSAKI; S. TSUDA; N. SUGIYAMA Issue Date 2013-09-11 Doc URL http://hdl.handle.net/2115/54200

More information

Study of Shear Walls in Different Locations of Multistoried Building with Uniform Thickness in Seismic Zone III

Study of Shear Walls in Different Locations of Multistoried Building with Uniform Thickness in Seismic Zone III Study of Shear Walls in Different Locations of Multistoried Building with Uniform Thickness in Seismic Zone III Ambreshwar 1, Mahesh D 2, Nithinchary 3, Satish Baag 4, Sachin 5 1,2 Assistant Professors,

More information

Full-scale dynamic testing of an 11-story RC building and interpretation of the results from the seismic-resistance viewpoint

Full-scale dynamic testing of an 11-story RC building and interpretation of the results from the seismic-resistance viewpoint Full-scale dynamic testing of an 11-story RC building and interpretation of the results from the seismic-resistance viewpoint I. Iskhakov * & Y. Ribakov * ' Department of Engineering, College ofjudea &

More information

Seismic analysis of vertically geometric irregular structures

Seismic analysis of vertically geometric irregular structures Seismic analysis of vertically geometric irregular structures 1 Prashanth Kumar N, 2 Dr. Y.M.Manjunath 1 PG Student, 2 Professor Department of Civil Engineering, The National Institute of Engineering,

More information

COMPARISON OF SEISMIC PERFORMANCE OF BASE-ISOLATED HOUSE WITH VARIOUS DEVICES

COMPARISON OF SEISMIC PERFORMANCE OF BASE-ISOLATED HOUSE WITH VARIOUS DEVICES COMPARISON OF SEISMIC PERFORMANCE OF BASE-ISOLATED HOUSE WITH VARIOUS DEVICES SHINJI NAKATA ) TSUTOMU HANAI ) SHIN-ICHI KIRIYAMA ) and NOBUO FUKUWA ) ) Asahi Kasei Homes Co., TOKYO 6-845, Japan Email:

More information

Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings

Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings I. Iskhakov & Y. Ribakov Department of Civil Engineering, Ariel University Center of Samaria, Israel

More information

Dynamic Time History Analysis of Plane Frame with Tuned Mass Considering Soil-Structure Interaction

Dynamic Time History Analysis of Plane Frame with Tuned Mass Considering Soil-Structure Interaction ١ Dynamic Time History Analysis of Plane Frame with Tuned Mass Damper by Considering Soil-Structure Interaction S. M. Mirhoseini hezaveh Civil Engineering Department, Islamic Azad University Arak Branch

More information

sixteen seismic design Earthquake Design Earthquake Design Earthquake Design dynamic vs. static loading hazard types hazard types: ground shaking

sixteen seismic design Earthquake Design Earthquake Design Earthquake Design dynamic vs. static loading hazard types hazard types: ground shaking APPLIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS FALL 2017 lecture sixteen dynamic vs. static loading amplification of static affect time duration acceleration & velocity

More information

RISK-BASED DECISION ANALYSIS FOR BUILDING SERVICEABILITY

RISK-BASED DECISION ANALYSIS FOR BUILDING SERVICEABILITY 8 th ASCE Specialty Conference on Probabilistic Mechanics and Structural Reliability PMC2000-237 RISK-BASED DECISION ANALYSIS FOR BUILDING SERVICEABILITY S. K. Yalla, Student Member ASCE, A. Kareem, M.

More information

Seismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers

Seismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers RESEARCH ARTICLE OPEN ACCESS Seismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers Yuvraj Bisht*, Saraswati Setia** *(Department of Civil Engineering, NIT Kurukshetra, Haryana, INDIA

More information

DESIGN OF SHEAR WALLS IN RESPONSE SPECTRUM METHOD USING ETABS

DESIGN OF SHEAR WALLS IN RESPONSE SPECTRUM METHOD USING ETABS DESIGN OF SHEAR WALLS IN RESPONSE SPECTRUM METHOD USING ETABS VENKATA SAI DINESH BONGARALA (1), V. Bhargavi (2) 1 Dept., of Civil Engg., M-Tech Student (Structural Engineering), Visaka technical campus

More information

Literature Review of Wood-frame Structure Tests

Literature Review of Wood-frame Structure Tests CHAPTER 2 Literature Review of Wood-frame Structure Tests This dissertation focuses on the investigative process of extracting dynamic characteristics of wood-frame structures from measured seismic response.

More information

Case Study: Challenges of a Single-layer Reticulated Dome

Case Study: Challenges of a Single-layer Reticulated Dome Case Study: Challenges of a Single-layer Reticulated Dome Naveed Anwar, Pramin Norachan, Thaung Htut Aung AIT Consulting, Asian Institute of Technology, Bangkok, Thailand Contact: nanwar@ait.asia Abstract

More information

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance APPLIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS SPRING 2017 lecture fifteen design for lateral loads Lateral Load Resistance stability important for any height basic

More information

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance APPLIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS FALL 2014 lecture fifteen design for lateral loads Lateral Load Resistance stability important for any height basic mechanisms

More information

Seismic Devices. Connection Isolation Dissipation

Seismic Devices. Connection Isolation Dissipation Seismic Devices Connection Isolation Dissipation Seismic Devices s u m m a r y Introduction PAGE 3 The Freyssinet solutions Isolation PAGE 4 Structural elastomeric bearings Sliding devices Connection PAGE

More information

CHAPTER 4. 1:6-Scale Frame: Stiffness and Modal Testing 4.1 OVERVIEW

CHAPTER 4. 1:6-Scale Frame: Stiffness and Modal Testing 4.1 OVERVIEW CHAPTER 4 1:6-Scale Frame: Stiffness and Modal Testing 4.1 OVERVIEW A 1:6-scale steel moment frame was designed for shaking-table experiments described in Chapter 5 based on Drain-2DX (DRAIN) analyses.

More information

Pushover Analysis of Structures with Plan Irregularity

Pushover Analysis of Structures with Plan Irregularity IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 12, Issue 4 Ver. VII (Jul. - Aug. 2015), PP 46-55 www.iosrjournals.org Pushover Analysis of Structures

More information

Study On Performance Of Regular And Vertically Irregular Structure With Dampers, Shear Wall And Infill Wall

Study On Performance Of Regular And Vertically Irregular Structure With Dampers, Shear Wall And Infill Wall Study On Performance Of Regular And Vertically Irregular Structure With Dampers, Shear Wall And Infill Wall Chaitra H N 1, Dr B Shivakumara Swamy 2 1Mtech Structural Student, Dept of Civil Engineering,

More information

N.Nageswarao Department of Civil Engineering, Amara Institute of Engineering and Technology.

N.Nageswarao Department of Civil Engineering, Amara Institute of Engineering and Technology. Comparison in Results and Analysis of Lateral Displacements Storey Drift of the RC Frames With Dampers to The RC Frames Without Damper Element and With Walls to Without Walls at all Seismic Zones in India

More information