1 Installation Manual SOLON SOLitaire EN SOLON SOLitaire. Installation Manual.

2 2

3 Installation Manual SOLON SOLitaire 3 Table of contents Introduction Before you start 4 Safety information 5 Applicable regulations 7 Installation conditions 8 Installation recommendations 9 Installation Explosion drawing 10 Componenets 11 Preparation: Calculation of module array dimensions 14 Installation step 1: Roof battens (support battens) 15 Installation step 2: Mounting battens 17 Installation step 3: Module installation 19 Installation step 4: Mounting battens for an additional vertical module row 21 Installation step 5: Installing another module row 22 Installation step 6: Installing the rubber seals 23 Installation step 7: Mounting battens for the last vertical module row 24 Installation step 8: Testing the electrical connection 26 Installation step 9 for 3 kwp-kit: Cover frame Installing the front parts 27 Installation step 10 for 3 kwp-kit: Installing the side parts 30 Installation step 11 for 3 kwp-kit: Installing the upper sheet metal covering 32 Installation step 9 for variable flashing: Cover frame Installing the front parts 35 Installation step 10 for variable flashing: Installing the side parts 38 Installation step 11 for variable flashing: Installing the upper sheet metal covering 40 Installation step 12: Final sealing measures 43 Additional information Maintenance and cleaning 45 Appendix Technical data sheet butyl sealant 46 Material safety data sheet butyl sealant 48

4 4 Before you start Please carefully read through this installation manual before beginning installation, operation or maintenance work. Failure to follow these installation instructions may result in damage or injury. Please keep this manual safe for future reference. Symbols used Danger! Risk of electrocution Risk of damaging the product or harming the environment Exclusion of liability No warranty is given or liability assumed for damage arising from incorrect installation. Required components The customer must provide some parts in addition to the supplied SOLON components. You can find an overview of these parts in the "installation" section.

5 Installation Manual SOLON SOLitaire 5 Safety information This installation manual is exclusively intended for qualified trade's people. Applicable health and safety regulations and procedures must be followed (in Germany, cf. BGV A1, BGV A2, BGV C22). We will not accept any liability for DIY installation and we strongly recommend that you hire a reputable firm. General hazard warnings Beware of risk of death by electrical shock or arcing. Pay close attention to the following features that are specific to photovoltaic systems: Modules contain voltage when light shines on them. The modules can only be isolated at the DC switch, which means the DC side of the system will still be live if a fault occurs (short circuit, earth fault). Electrical arcing that cannot be extinguished can be produced when contacts in use are disconnected. Do not insert any (electrically conductive) parts into the plugs or sockets of the modules. Do not install solar modules and wiring using wet plug connectors. Make sure that tools are dry and the work is performed under dry conditions. Observe the inverter manufacturer's installation regulations. Do not use damaged modules. Keep children away from modules, inverters, and other current-carrying components in the system. Perform all work on the wiring with extreme caution. Observe the safety instructions issued by manufacturers of all other system components. General warnings Do not remove any part or type plate attached by the manufacturer. Do not dismantle modules. Do not expose modules to artificially concentrated sunlight. Do not use paint, adhesives or sharp implements on the modules. Do not clean modules with solvent-based cleaning agents. Before installing the system, check the structural strength of the building and the system itself. The module is only intended for use in temperate climates (see the installation conditions section for more details.

6 6 Warnings relating to storage, unpacking and transportation Exercise the utmost care at all times when handling modules. Always transport modules in their correct packaging. Always carry the modules with both hands. Wear protective gloves. Do not hold modules by their connection boxes or leads. Avoid bending or flexing the modules. Do not place heavy items on modules. Do not stand on modules. Do not let modules fall over. Do not use sharp implements on the modules. Keep all electrical contacts clean and dry. Store modules in a dry place prior to fitting. The roof-integrated system must be grounded. Fasten the grounding cable (Cu, at least 16 mm 2, UV-resistant) at a suitable electrically-conducting location on the covering frame and on the building's equipotential bonding bar using a screw connection. All metal parts must be interconnected in an electrically-conducting fashion. We recommend you make a note of the module serial numbers for any future enquiries.

7 Installation Manual SOLON SOLitaire 7 Applicable regulations Please make sure both before and during installation that the locally applicable standards, building regulations and health and safety rules are being followed. In addition to any local regulations, the following standards and regulations in particular should be observed. DIN VDE 0100 VDE 0105 T100 VDI 6012 sheet 2 VDE 0298 T4 DIN DIN DIN DIN DIN DIN DIN 1055/ DIN EN part 1-4 VDE 0185 DIN EN DIN V VDE V High Voltage installations with nominal voltages of up to 1,000 volts, all relevant sections especially T712 Operation of electrical installations Decentralized energy systems in buildings Rubber insulated wiring Electrical wiring in buildings Carpentry and timber structures Roof covering and roof sealing Plumbing Facades Scaffolding Load assumptions for supporting structures Lightning protection German roofing trade regulations Photovoltaic system performance monitoring Automatic circuit breaker for PV systems Technical connection requirements (TAB) for connecting to the energy utilities' low-voltage grid VDEW regulations for domestic power generation systems in the lowvoltage grid Accident prevention regulations issued by the Berufsgenossenschaften (employer's liability insurance associations) BGV A1 BGV A2/A3 BGV C22 BGV D36 General regulations Electrical systems and equipment Construction work (personal protective equipment against falls from a height) Ladders and steps The listed standards and regulations are merely a representative selection. The list does not claim to be complete. (Last revised in March 2009.)

8 8 Installation conditions The SOLON Black 160/05 module dimensions are based on the measuring templates provided in DIN 1055; DIN EN parts 1 4. The SOLON Blue 250/05 or SOLON Black 250/05 module fulfills the functions of a conventional roof covering on pitched roofs in terms of protection from the weather provided the following conditions are satisfied: Roof pitch from 10 to 60. A waterproof sarking membrane must be used with roofs with pitches ranging from 10 to 22. The roof must comply with state-of-the-art technology as well as current standards and regulations, e.g. tight, stable roof battens waterproof sarking membrane The construction work is completed by a specialist company and all points specified in this manual were precisely observed (construction work according to regulations). The following points must be considered when installing the modules: Auxiliary mounting boards and battens should not be directly exposed to moisture. During the installation, the wood must be dry. Otherwise, the stability of the screw can not be guaranteed. Sufficient rear ventilation of modules to prevent power losses due to heat accumulation. This can be improved by also using ventilation tiles. Do not install modules in the vicinity of highly flammable gases and vapors (e.g. gas containers, gas stations, spray-painting systems). Do not install modules near naked flames and flammable materials. > Do not expose modules to concentrated light. Do not expose modules to high concentrations of salt (recommended distance from the sea is at least 500 m) or sulfur (volcanoes) conditions, as this creates a risk of corrosion. Do not install modules as overhead glazing or as facade elements.

9 Installation Manual SOLON SOLitaire 9 Installation recommendations Orientation and tilt For the installation inclination, observe the installation conditions for this module type. In Europe, the modules should ideally face south. In central Europe, the optimal tilt angle for the modules is around 30. The tilt angle is somewhat steeper in northern Europe and somewhat flatter in southern Europe. Deviating from the optimal orientation and tilt will reduce the system's energy yield. The graphic below serves as a guide. Percentage energy yield depending on roof orientation Absence of shading A module is considered to be shadow-free if no shadow is cast across its entire surface all year round i.e. nothing blocks the sunlight shining on it. Even small areas of partial shading caused for example by chimneys, roof aerials, buildings, trees (what happens when they grow?) and lamp posts will result in a reduced yield. Modules should therefore be installed where shading is at a minimum throughout the day, or preferably where there is no shading at all. If necessary, a shading analysis can be performed using a simulation tool or solar altitude analyzer. Temporary shading caused by dirt (dust, bird droppings, leaves, etc.) can also diminish yields. For notes on how to remove this soiling, see the "maintenance" section. Rear ventilation Module performance decreases with increasing temperatures. Reliable rear ventilation must therefore be ensured. Using additional ventilation tiles can reduce heat build-up that reduces performance.

10 10 Explosion drawing a) 3 kwp-kit 14a 13a 12a 2 11a b) Variable flashing 14b 11b b 3 12b c

11 Installation Manual SOLON SOLitaire 11 Components Item Figure Description 1 SOLON Blue 250/05 SOLON Black 250/05 2 SOLON hexagonal self-tapping wood screws with sealing washer; DIN 7995; 5.5 x 43 mm 3 SOLON rubber seal SOLON cover frame 4 Left front part with aluminum skirting with butyl sealing 5 Center front part with aluminum skirting with butyl sealing 6 Right front part with aluminum skirting with butyl sealing 7 Sealing screw 8 Left side part 9 Right side part 10 Bracket with roofing nail (for side part) 11a Left upper part (kit)

12 12 Item Figure Description 11b Left upper part (variable) 12a Right upper part (kit) 12b Right upper part (variable) 13a Center upper part (kit) 13b Center upper part (variable) 14 Groove sealing strip (snow stop) 15 Mounting batten 16 Support batten (roof batten) 17 Screw (self-tapping wood screw for fastening the roof battens and mounting battens) 18 Sealing screw (long) 19 Underplate 20 Cover plate 21 Special sealing screw (for cover plate)

13 Installation Manual SOLON SOLitaire 13 Required tools for mounting the modules Cordless screwdriver Pliers Crimping and pulling pliers Multimeter Angle grinder with diamond grinding wheel Hammer Hand press We recommend using neutral detergent with a cloth/brush to easily mount the rubber seals. This installation manual describes installations performed from left to right. The installation can also be started from the right.

14 14 Preparation: Calculation of module array dimensions The modules including the sheet metal can only be installed in a roof area that has a uniform pitch. Roof tiles At least two roof tiles must remain around each module array to be installed. Modules The modules are x m (height x width). A gap of 0.01 m must be kept between the modules. Sheet metal The side parts require an additional space of 0.12 m (2 x 0.06 m). For the front and upper parts, an additional space of approx m must be calculated in the module array height. Calculation of module array width Number of modules x 1.04 m + Number of modules 1 x 0.01 m = + 2 Side parts 0.12 m = = Result Calculation example: 6 modules next to each other 6 x 1.04 m = 6.24 m x 0.01 m = 0.05 m m = 0.12 m = 6.41 m The module array for six modules will be 6.41 m wide from the right to the left tile edge (plus four roof tiles). Two roof tiles are also required on each side for calculating the module array width. Calculation of module array height The overlap at the bottom of the frame reduces each module size from 6 cm to 1.72 m. Number of modules x 1.72 m = m = = Result Calculation example: 2 modules above each other 2 x 1.72 m = 3.45 m m = 0.40 m = 3.85 m The module array for two modules arranged above each other will be 3.85 m high (plus four roof tiles). Two roof tiles are also required above and below the array for calculating the module array height.

15 Installation Manual SOLON SOLitaire 15 Installation step 1: Roof battens (support battens) The roof battens (support battens) must be supplied by the customer. The support battens secure the module on the roof. The use of waterproof battens with a minimum thickness of 26 mm is required. Quantity You require a total of five rows of timber beams/roof battens. Their respective length is calculated using the number of modules next to each other x 1.05 m. If your module array is wider than the roof battens available at your specialized dealer, the total length can also be created by shorter individual parts 2 Modules 5 rows of roof battens, each 2.10 m 6 Module 5 rows of roof battens, each 6.30 m 3 Modules 5 rows of roof battens, each 3.15 m 7 Module 5 rows of roof battens, each 7.35 m 4 Modules 5 rows of roof battens, each 4.20 m 8 Module 5 rows of roof battens, each 8.40 m 5 Modules 5 rows of roof battens, each 5.20 m Any cut edges created on support battens must be protected against mold growth, etc. using suitable wood preservative. Remove a suitable number of roof tiles, according to the space required. In the first work step, two support battens are installed in the lower area. They serve to secure the modules from sliding during the subsequent installation. Using straight roof battens simplifies the subsequent installation.

16 Screw the first, lower support batten (16) on the counter batten or roof batten using screws (17) provided by the customer. In doing so, make sure that the clearance (lower edge) to the underlying roof batten (upper edge) is 190 to 210 mm apart. In case there is an existing covering with lower tile rows, the clearance of the support batten (lower edge) to the top edge of the existing tiles should be 170 mm. The clearance on the side to the roof covering must be at least 100 mm The height of the reinforced support battens may extend past the height of the existing roof battens by no more than 43 mm. Reinforce the installed support batten (16) according to drawing by tightening further support battens (16) on top of it using screws (17). To ensure sufficient rear ventilation of modules the reinforced support batten may not be continuous.

17 Installation Manual SOLON SOLitaire 17 Installation step 2: Mounting battens The mounting battens are used to secure the modules. They are vertically screwed onto the roof battens. The mounting battens and the fastening screws must be provided by the customer. Requirements stipulate using waterproofed mounting battens with a thickness of 24 mm and a width of 140 mm to 180 mm. Make sure to use the correct screw lengths. Screws that are too short compromise the system's structural strength. Screws that are too long can damage the underlying waterproof sarking membrane. Length Each module requires battens with a length of 1.72 m. 1 module 1.72 m 2 modules 3.45 m 3 modules 5.17 m 4 modules 6.90 m 5 modules 8.62 m The length of the mounting battens depends on the number of modules arranged above each other. Any cut edges created on mounting battens must be protected against mold growth, etc. using suitable wood preservative. Quantity For each vertical module row, two mounting battens are required, plus another final mounting batten per module array. The number of mounting battens is calculated using: the number of vertical module rows x Number of modules Number of mounting battens Number of modules Number of mounting battens Number of mounting battens

18 Tighten the left mounting batten (15) on the roof battens using screws (17). In doing so, make sure that the clearance from the left edge of the mounting batten to the roof covering is 100 mm. Tighten the center mounting batten (15) on the roof battens using screws (17). In doing so, make sure that the clearance from the center of the middle mounting batten to the left outer edge of the left mounting batten is 350 mm. Tighten another two mounting battens (15), with a clearance of 350 mm from the center of one mounting batten (15) to the center of the other mounting batten (15), on the roof battens using screws (17). If the module array height is taller than the used mounting battens (15), they may need to be extended vertically by placing several mounting battens (15) together. When placing the mounting battens (15) together vertically, make sure that no module screw is placed on the joint between two battens they are tightened with at least two roof battens.

19 Installation Manual SOLON SOLitaire 19 Installation step 3: Module installation The modules must not be subjected to any force, for example, stepping, leaning, etc. on the modules, during the entire installation! First, place the SOLON Blue 250/05 or SOLON Black 250/05 (1) on the mounting battens (15) and carefully let it slide down to the reinforced supporting battens (16). Align the side of the module (1) parallel to the tile covering. The mounting batten (15) must extend past the module edge by at least 10 mm and may not protrude by more than 20 mm. Check the alignment of the module (1) to the roof covering and adjust it if necessary. Tighten the module (1) on the mounting battens (15) using the provided SOLON hexagonal self-tapping wood screws (2) with the sealing washers.

20 Make sure that the cables are fed through under the mounting battens (15). The modules (1) must not lie on the cables. Position the second module (1) on the mounting battens (15) above the first module. Establish the electrical connection of the modules (1) using the preassembled connector system according to the wiring diagram Align the side of the second module (1) to the roof Covering and tighten it onto the mounting battens (15) using the provided SOLON hexagonal self-tapping wood screws (2) with the sealing washers. Repeat the installation steps for installing additional horizontal module rows accordingly.

21 Installation Manual SOLON SOLitaire 21 Installation step 4: Mounting battens for an additional vertical module row Tighten three more mounting battens (15) on the roof battens with screws (17) for the next row of modules. In doing so, make sure that the clearance from the middle of the next mounting batten (15) to the module edge is 350 mm. Tighten the next two mounting battens (15) on the roof battens using screws (17). In doing so, make sure that the clearance from the center of one mounting batten (15) to the center of the other mounting batten (15) is 350 mm. If necessary, extend the mounting battens by placing them together vertically. When placing the mounting battens together vertically, make sure that no module screw is placed on the joint between two battens they are tightened with at least two roof battens.

22 22 Installation step 5: Installing another module row Set the lower module (1) on the mounting battens (15) on the right, next to the module that is already installed and slide them together. The two spacers on the side predetermine the 10 mm distance between the modules (1). Make sure that the cables are fed through under the mounting battens (15). The modules (1) must not lie on the cables. Establish the electrical connection of module (1) using the preassembled connector system according to the wiring diagram. Tighten the module (1) on the mounting battens (15) using the provided SOLON hexagonal self-tapping wood screws (2) with the sealing washers. Install additional modules (1) according to the previous installation steps.

23 Installation Manual SOLON SOLitaire 23 Installation step 6: Installing the rubber seals To facilitate the installation, mount each rubber seal (3) immediately after installing two vertical module rows. To make the installation easier, apply lubricant (e.g. detergent) to the underside of the rubber seal (3) Press down the SOLON rubber seal (3) from above into the gap between the modules (1) so that it is flush. Secure the SOLON rubber seal (3) at the top (on the ridge) of the mounting batten using a sealing screw (18). Cut the rubber seal (3) so that there is no overlap. The loose lower end is tightened in the last step after the frame is installed.

24 24 Installation step 7: Mounting battens for the last vertical module row Tighten the last (left) mounting batten (15) for the last vertical module row to the roof battens using screws (17). In doing so, make sure that the clearance from the middle of the mounting batten (15) to the module edge is 350 mm. Tighten the last mounting batten on the right (15) onto the roof battens using screws (17). In doing so, make sure that the clearance from the right side of the mounting batten (15) to the module edge is 1,064 mm to max. 1,074 mm. The two lower support battens (16) may not extend past the right side of the last mounting batten (15). Shorten the support battens if necessary.

25 Installation Manual SOLON SOLitaire Set the lower module (1) onto the mounting battens, to the right of the module that is already installed (1) and slide them together. The two spacers on the side predetermine the 10 mm distance between the modules (1). Make sure that the cables are fed through under the mounting battens. The modules must not lie on the cables. Establish the electrical connection of module (1) using the preassembled connector system according to the wiring diagram. Tighten the module (1) on the mounting battens (15) using the provided SOLON hexagonal self-tapping wood screws (2) with the sealing washers. Install rubber seal (3) according to installation step 6. Install additional modules (1) according to the previous installation steps. Danger! The inverter may not be connected to the AC system while the DC wiring is routed. Modules may only be connected to the inverter after the electrical connection has been tested (installation step 8) and the cover frame has been installed (installation step 10). Make sure the polarity and connection are correct. Danger! Tightly route the solar cables together so that they are parallel and make sure there are no loops. Otherwise there is a risk of an indirect lightning strike. Twist the solar cables together loosely. The solar cables must be compatible with the module connector system. For this, see the manufacturer's specifications. Connect the string cable to the modules (1) using a suitable solar connector. In doing so, make sure that the plug connection locks into place. If necessary, route any exposed solar cables through a protective tube or hose to protect them against damage.

26 26 Installation step 8: Testing the electrical connection Danger! Modules may only be connected to the inverter after the electrical connection has been tested. The electrical connection must be tested before the cover frame is installed. Measure the string's open-circuit voltage for each series connection. If the measured values strongly vary from the specifications, there is a connection error. The open-circuit voltage corresponds approximately to the open-circuit voltage specifications in the module data sheet times the number of modules of this string connected in series. In case of doubt, please refer to the corresponding target values in the flash report on the installed modules provided by SOLON. The open-circuit voltage depends on the module temperature. Its value decreases as the module temperature increases. As a result, it is normal if the measured value slightly varies from the calculated standard value. Measure the string's short-circuit voltage for each series connection. If the measured values strongly vary from the specifications, there is a connection error. The target values of the short-circuit current correspond approximately to the short-circuit current specifications in the module data sheet. In case of doubt, please refer to the corresponding target values in the flash report on the installed modules provided by SOLON. The short-circuit current depends on the irradiation level on the module. Its value decreases as the irradiation level increases. As a result, it is normal if the measured value slightly varies from the calculated standard value. The short-circuit current should be approx. 90 % of the value specified in the module data sheet on a clear day and approx. 10 % on cloudy days. Danger! The grid connection may only be carried out by appropriately authorized specialist staff. The regional conditions and requirements arranged with the pertinent grid operator must be observed.

27 Installation Manual SOLON SOLitaire 27 Installation step 9 for 3 kwp-kit: Cover frame Installing the front parts The front parts are an integral part of the SOLON cover frame. They are installed below the module array. There is a left front part (4), a center front part (5) and a right front part (6) Tighten an additional support batten (16) so that it is flush, directly underneath the lower reinforced supporting batten (see installation step 1) on the counter battens/roof battens with screws (17). This roof batten may overlap with the roof batten above it on the side, but it is not necessary.

28 The sides of the corner parts, i.e. left front part (4) and right front part (6) must be flush with the outer edge of the mounting battens. Slide the left front part (4) under the module sealing lip to the upper support batten (16). Align the side of the sheet metal on the module and secure it on the lower support batten (16) using sealing screws (7) Slide the center front part (5) sideways into the sheet metal, which is already installed, to the top support batten (16) and secure it on the lower roof batten using sealing screws (7). Install the other center front part (5) the same way you installed the first center front part.

29 Installation Manual SOLON SOLitaire Finally, slide the right front part (6) to the upper support batten (16), hook it into the module (1), align it on the side of the module and secure it to the lower roof batten using sealing screws (7). Fit the aluminum skirting to the shape of the roof tiles. Remove the liner or protective foil of the butyl sealant which is attached under the aluminium skirting. Then press aluminium skirting down firmly on roof tiles. Please follow the application instructions of the butyl sealant (see appendix).

30 30 Installation step 10 for 3 kwp-kit: Installing the side parts The side parts are an integral part of the SOLON cover frame. There is a left side part (8) and a right side part (9). They are installed on the sides of the module array Always start from below when installing the side parts (8, 9). Inside the side parts, there is an angled sheet metal strip riveted along their entire length. This sheet metal strip must be hooked into the side edge of the modules (1) to ensure the system is watertight. Applying light pressure from above, position the left side part (8) on the module (1) and hook it onto the module profile by applying pressure from the side. When installing the side parts (8, 9), bend the seam of the respective underlying sheet metal slightly upwards. This makes it easier to install the side parts (8, 9) and the upper sheet metal.

31 Installation Manual SOLON SOLitaire When installing the side part, make sure that its lower end is flush with the module's sealing lip. Install the upper left side part (8) the same way you installed the lower left side part. Bend the bent seam of the lower left side part (8) back into its original position Nail the left side part (8) with the bracket (10) to every second roof batten. Finally, install the right side parts (9) the same way you installed the left side parts (8).

32 32 Installation step 11 for 3 kwp-kit: Installing the upper sheet metal covering The upper parts are an integral part of the SOLON cover frame. They are installed above the module array. There is a left upper part (11a), a right upper part (12a) and a center upper part (13a). 16 Screw two support battens (16) onto the counter battens/ roof battens above the upper module. The battens must be positioned so that the upper section of each upper part lies on the battens.

33 Installation Manual SOLON SOLitaire 33 11a a 8 Sheet metal strips are installed on the inside of the upper parts and must be hooked into the cut-outs below the modules during installation. Applying light pressure from above, slide the left upper part (11a) onto the left side part (8). Applying light pressure, simultaneously slide the left upper part (11a) down until the sheet metal hooks into the module (1). Tighten the left upper part (11a) onto the upper support batten (16) with four or five sealing screws (7). 12a Install the right upper part (12a) the same way you installed the left upper part.

34 a Install the center upper part (13a) on both the left upper part (11a) and the right upper part (12a). To do this, first apply a bead of silicon on each overlap. Applying light pressure, slide the center upper part (13a) down until the sheet metal hooks into the module (1). Finally, tighten the center upper part (13a) on the upper support batten (16) with four or five sealing screws.

35 Installation Manual SOLON SOLitaire 35 Installation step 9 for variable flashing: Cover frame Installing the front parts The front parts are an integral part of the SOLON cover frame. They are installed below the module array. There is a left front part (4) and a right front part (6). Starting with a number of three vertical module rows, the center front part (5) will also be installed Tighten an additional support batten (16) so that it is flush, directly underneath the lower reinforced supporting batten (see installation step 1) on the counter battens/ roof battens with screws (17). This roof batten may overlap with the roof batten above it on the side, but it is not necessary

36 36 The sides of the corner parts, i.e. left front part (4) and right front part (6) must be flush with the outer edge of the mounting battens. Slide the left front part (4) under the module sealing lip to the upper support batten (16). Align the side of the sheet metal on the module and secure it on the lower support batten (16) using sealing screws (7) Starting from at least three vertical module rows, "center front parts" (5) must be installed. Slide the center front parts (5) sideways into the sheet metal, which is already installed, to the top support batten (16) and secure it on the lower roof batten using sealing screws (7). If applicable, install the other center front part (5) the same way you installed the first center front part

37 Installation Manual SOLON SOLitaire 37 Finally, slide the right front part (6) to the upper support batten (16), hook it into the module (1), align it on the side of the module and secure it to the lower roof batten using sealing screws (7). Fit the aluminum skirting to the shape of the roof tiles. Remove the liner or protective foil of the butyl sealant which is attached under the aluminium skirting. Then press aluminium skirting down firmly on roof tiles. Please follow the application instructions of the butyl sealant (see appendix).

38 38 Installation step 10 for variable flashing: Installing the side parts The side parts are an integral part of the SOLON cover frame. There is a left side part (8) and a right side part (9). They are installed on the sides of the module array Always start from below when installing the side parts (8, 9). Inside the side parts, there is an angled sheet metal strip riveted along their entire length. This sheet metal strip must be hooked into the side edge of the modules (1) to ensure the system is watertight. Applying light pressure from above, position the left side part (8) on the module (1) and hook it onto the module profile by applying pressure from the side. When installing the side parts (8, 9), bend the seam of the respective underlying sheet metal slightly upwards. This makes it easier to install the side parts (8, 9) and the upper sheet metal.

39 Installation Manual SOLON SOLitaire When installing the side part, make sure that its lower end is flush with the module's sealing lip. Install the upper left side part (8) the same way you installed the lower left side part. Bend the bent seam of the lower left side part (8) back into its original position Nail the left side part (8) with the bracket (10) to every second roof batten. Finally, install the right side parts (9) the same way you installed the left side parts (8).

40 40 Installation step 11 for variable flashing: Installing the upper sheet metal covering The upper parts are an integral part of the SOLON cover frame. They are installed above the module array. Included in the basic set are a right upper part (12b) and a left upper part (11b). The number of vertical module rows can be increased with the upper part of the extension set (center upper part (variable)(13b)). Screw two support battens (16) onto the counter battens/ roof battens above the upper module. The battens must be positioned so that the underplate (19) rests on the bending and at the end. Place underplate (19) between two modules (1) on the upper module profile and fasten using two screws (17).

41 Installation Manual SOLON SOLitaire 41 Sheet metal strips are installed on the inside of the upper parts and must be hooked into the cut-outs below the modules during installation. Applying light pressure, slide down the left upper part (11b) onto the left side part (8) until the sheet metal hooks into the module (1). Tighten the left upper part (11b) onto the upper support batten (16) with two or three sealing screws (7). Starting from at least three vertical module rows, under light pressure slight down one center upper part (13b) to the module (1). Make sure that the center upper part (13b) is aligned to the center of the module.

42 42 Tighten the center upper part (13b) onto the upper support batten (16) with two or three sealing screws (7). If applicable, mount additional center upper parts (13b) according to the first center upper part. Finally, mount right upper part (12b) according to left upper part (11b). Do not exchange mounting positions of sealing screw (7) and special sealing screws (21). Screw the cover plates (20) on the underplates (19) using two special sealing screws (21) and one sealing screw (7).

43 Installation Manual SOLON SOLitaire 43 Installation step 12: Final sealing measures The groove sealing strips (14) are self-adhesive. Cut the groove sealing strips (14) to length accordingly and glue them to the upper parts (11, 12, 13). If necessary, also attach groove sealing strips (14) on the side parts (8, 9). 3 7 Tighten the lower end of the SOLON rubber seal (3) on the support batten using a sealing screw (7). To do this, cut back the SOLON rubber seal's lower strip profile (3), which cannot be compressed.

44 The roof covering must lie on the upper parts (11, 12, 13) up to the height of the upper parts' first beam edge. If necessary, shorten the roof tiles accordingly. Insert the missing roof tiles on the side. In doing so, shorten the roof tiles to the correct size, if necessary.

45 Installation Manual SOLON SOLitaire 45 Maintenance and cleaning In general, SOLON modules are tilted at a sufficient angle to allow rainwater to wash away dust and dirt. Snow will usually also slide off SOLON modules without any intervention. If modules are heavily soiled, they can be cleaned using copious amounts of water and a gentle cleaning implement such as a sponge. Danger! When carrying out maintenance and cleaning work, please observe and comply with the safety information and warnings in the "safety information" and "applicable regulations" sections. Maintenance and cleaning should only be carried out by a specialist firm. Do not use any cleaning agents or abrasive cleaning implements on SOLON modules. Cleaning may slightly improve the yield. This is particularly true for heavy soiling caused by leaves or bird droppings that may result in partial shading. Yield losses caused by snow, however, are negligible as the yield is lowest at this time of year anyway. In addition, the PV system should be serviced by a specialist company at fixed intervals (e.g. every three years). The following points should be checked: Stability of the battens Proper functioning of the protection elements Measurements of string voltages and currents Secure fit of the sealing elements Legal requirements regarding the inspection of PV systems that do not have a MSD (mains monitoring device for the inverter) must be observed.

46 Adhesives and sealants for industrial application TECHNICAL DATA SHEET Butyl Sealants Butyl 1185 gray - Butyl sealant in profile form - PRODUCT DESCRIPTION Thermoplastic sealant with very high surface tack. Suitable for sealing joints that do not bear mechanical forces. Transportation Construction Roof / Facade Industry APPLICATIONS Suitable for interior and exterior application Sealing of lap joints Bonding and fixation foils and light weight materials Temporary fixation Corrosion protection in metal joints especially between dissimilar materials Vibration and sound deadening Assembly Solar CHARACTERISTICS Permanent plastic and permanent tacky Aging and weather resistant Good water resistance Good water vapour tightness Good adhesion to almost all substrates Odour free at room temperature Long-term resistant Solvent free Shrinkage free PROCESS INSTRUCTIONS The Butyl 1185 profiles are applied direct from the roll to one side of the joint. Cut according to the required length and remove the release paper and press the counter part to the sealing strip (best using a roll). PACKAGING Single rolls in different dimensions on siliconized release liner. Also in sausages as semifinished product for processing with extruders. - Page 1 of 2 -

47 TECHNICAL DATA SHEET Butyl 1185 gray - Page 2 - TECHNICAL DATA Chemical base: Colour: Synthetic rubber (Base IIR / PIB) gray Density (Pycnometer; 23 C): 1,35 1,45 g / ml (orienting to DIN EN ISO ) Penetration (150g cone; 20 C; 5sec): / 10mm (orienting to DIN 51580) Melt index (140 C; 5kg; 2mm nozzle): ml / 10min (orienting to DIN EN ISO ) Softening point (Ring & Ball; glycerol): > 160 C (orienting to DIN EN 1238) Peel strength (180 -Peel; 23 C; 200 mm / min ): > 1,0 N / mm (cohesive) (orienting to DIN EN ISO ) Water vapour tightness (diffusion resistance): approx µ (orienting to DIN 53122) as s d -value (for 1mm layer thickness): approx. 250 m (orienting to DIN 53122) ADHESION Very good to a variety of different materials. In contact with plastic materials a migration of plasticizer may occur - we recommend to carry out tests before application! Surfaces must be dry and mostly clean, free of dust, oil or grease. STABILITY From -30 C to 90 C temperature - and form stable. Butyl 1185 behaves thermoplastic: At low temperatures the hardness increases, at high temperatures the mass becomes softer and tackier. Good aging resistant, especially under warm and humid conditions. Stable against water and saltwater in the range of ph 5 9. Not resistant against oil, grease, white spirit and other solvents. CLEANING Remove main portions mechanically ( dab off ). Residuals can be cleaned with BOSTIK Solvent 280 or white spirit. STORAGE Store under dry conditions in original packaging. Protect against mechanical deformation and dust. Shelf life at least 24 months. SAFETY INSTRUCTIONS Observe the standard hygienic precautions for chemical goods when working with Butyl 1185: Do not eat, drink or smoke Avoid contact with eyes and skin Wash hands before breaks and after end of work FOR FURTHER INFOMATION PLEASE REFER TO OUR MATERIAL SAFETY DATA SHEET. Bostik HL 09/2011 These instructions are designed to provide you with the best advice we can give based on our tests and experience. However, as a result of the large number of possible applications and the storage and application conditions which are beyond our control, we cannot offer a guarantee for the results of individual cases when using our products. We recommend that you carry out your own tests. Our technical and commercial advice service is available to you with the publication of this data sheet all earlier versions are void. GERMANY Bostik GmbH An der Bundesstraße 16 D Borgholzhausen Tel.: +49 (0) 5425/801-0 Fax.: +49 (0) 5425/ info.germany@bostik.com AUSTRIA Bostik GmbH Papierfabrikstraße 1 A-4600 Wels Tel.: +43 (0) 7242/53010 Fax.: +43 (0) 7242/ info.austria@bostik.com NETHERLANDS Bostik B.V. De Voerman 8 NL-5201 AH s-hertogenbosch Tel.: +31(0) Fax: +31(0) infonl@bostik.com BELGIUM Bostik Belux S.A.-N.V. Meulestedekaai 86 B-9000 Gent Tel: +32 (0) Fax:+32 (0) info@bostik.be POLAND Bostik Polska Sp.z o.o ul. Sredzka 8 PL Kleszczewo / k.poznania Tel: +48-(0) Fax:+48-(0) biuro@bostikpolska.pl

48

49

50

51

52

53 53 SOLON Energy GmbH Am Studio Berlin Germany Phone Fax /12

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev MANUAL METAL ROOF MOUNTING SYSTEM EN landscape orientation portrait orientation metal roof mounting system for solar panels ESDEC BV 2018 CONTENTS 1. Introduction 1 2. General installation conditions 1

More information

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs Photovoltaic mounting systems Assembly Instructions TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs 1 Table of contents 1 Introduction 1.1 Intended use 3 1.2 About the document

More information

INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF

INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF ALUMERO GROUP YOUR BIG ADVANTAGE! + in-house consulting and design office + competent and reliable staff + aluminium mounting profiles and custom-drawn

More information

IEC Installation Guide for SERAPHIM Photovoltaic Module

IEC Installation Guide for SERAPHIM Photovoltaic Module SUSA [InstallationGuide] 2016.11_V1.0 IEC Installation Guide for SERAPHIM Photovoltaic Module Table of Contents 2 Purpose of this guide General safety Handling safety Installation safety Fire safety 5

More information

Conergy SolarFamulus II

Conergy SolarFamulus II Conergy SolarFamulus II Installation manual www.conergy.com Table of Contents Table of Contents SolarFamulus II for universal use on flat roofs 1 Introduction 1 1.1 Short description 1 1.2 Intended use

More information

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev MANUAL EN MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES mounting system for pitched roof with tiles for solar panels in landscape setup ESDEC BV 2016 TABLE OF CONTENT 1. Introduction 1 2. General installation

More information

Tindo Karra. Installation and Specifications Manual. Introduction

Tindo Karra. Installation and Specifications Manual. Introduction Tindo Karra Installation and Specifications Manual Introduction Thank you for choosing a Tindo Solar Module. Background to our name TINDO Tindo is a word from the Kaurna warra Aboriginal language which

More information

Installers Guide. Item

Installers Guide. Item Installers Guide Item 17060-01 Required tools and fixings Electric drill (non-impact setting) T-25 Torq bit (wedge type) Pozi head drill bit Tape measure Pencil/pen Hammer Tin snips Angle grinder (to cut

More information

Mounting System MCG 3.0 Membrane-Connected Glass. System description

Mounting System MCG 3.0 Membrane-Connected Glass. System description Mounting System MCG 3.0 Membrane-Connected Glass System description SUNOVA MCG 3.0 System Fields of application: Not suitable for: (please inquire for other SUNOVA systems) The SUNOVA MCG 3.0 system is

More information

On-roof system Tau Installation manual

On-roof system Tau Installation manual On-roof system Tau Installation manual 810-0052 Table of Contents 1 Introduction 1 1.1 Short description 1 1.2 Intended use 1 1.3 Standards and guidelines 1 1.4 About these instructions 1 Tau The innovative

More information

COSMOFIN FG Welding Guidelines

COSMOFIN FG Welding Guidelines COSMOFIN FG roofing membranes can be welded homogeneously to produce a permanently waterproof seal using hot air and solvent welding (diffusion bonding) processes. It is preferable to weld larger seam

More information

SQUARE SUN TUNNEL INSTALLATION INSTRUCTION

SQUARE SUN TUNNEL INSTALLATION INSTRUCTION SQUARE SUN TUNNEL INSTALLATION INSTRUCTION Please leave these installation instructions with the owner of the Sun Tunnel. This will enable them to carry out the straightforward maintenance mentioned below.

More information

Kingspan Day-Lite Klick

Kingspan Day-Lite Klick Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual Solarion M210T General Information This document contains important information for the installation of Solarion M210T solar modules from OC3 AG. Please read this document

More information

TRAPEZOIDAL SHEET METAL RAIL

TRAPEZOIDAL SHEET METAL RAIL Photovoltaic Mounting Systems Assembly Instructions TRAPEZOIDAL SHEET METAL RAIL Mounting system for roofing with trapezoidal sheet metal S:FLEX GmbH 09/2017 / design and engineering is subject to change

More information

MANUAL. portrait set-up. landscape set-up. ClickFit Evo mounting system for sloping roofs with roof tiles for solar panels

MANUAL. portrait set-up. landscape set-up. ClickFit Evo mounting system for sloping roofs with roof tiles for solar panels MANUAL MOUNTING SYSTEMS FOR SLOPING ROOFS WITH ROOF TILES EN portrait set-up landscape set-up ClickFit Evo mounting system for sloping roofs with roof tiles for solar panels ESDEC BV 2017 CONTENTS 1. Introduction

More information

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR INSTALLATION INSTRUCTIONS ENERGY AND SANITARY SYSTEMS Installation requirements Generel requirements The on-roof attachment set is capable for installation of

More information

ST-AK 1/12. Photovoltaic Mounting Systems. Assembly Instructions. Mounting system for roofing with trapezoidal sheet metal

ST-AK 1/12. Photovoltaic Mounting Systems. Assembly Instructions. Mounting system for roofing with trapezoidal sheet metal Photovoltaic Mounting Systems Assembly Instructions ST-AK 1/12 Mounting system for roofing with trapezoidal sheet metal S:FLEX GmbH 09/2017 / design and engineering is subject to change 1 Index 1 Introduction

More information

SoliTek PV Modules INSTALLATION MANUAL

SoliTek PV Modules INSTALLATION MANUAL SoliTek PV Modules INSTALLATION MANUAL Version: 16 10 14 According to: IEC 61215 IEC 61730 For: SOLID PRO 300-310 W p SOLID PRO 250-260 W p SOLID PRO 150-160 W p Thank you for choosing SoliTek panels.

More information

TallSlateTM Grandee Installation Manual

TallSlateTM Grandee Installation Manual TallSlateTM Grandee Installation Manual PLEASE READ THIS GUIDE COMPLETELY BEFORE INSTALLING OR USING THE SOLAR ELECTRIC MODULES Disclaimer of Liability...2 General Information...2 General Safety...2 TM

More information

SOLARWATT EASYIN SYSTEM

SOLARWATT EASYIN SYSTEM nergymanager configuration Device installation Preparation and planning EN SOLARWATT EASYIN SYSTEM ROOFING FRAME INSTALLATION INSTRUCTIONS FOR MODULE EASYIN 60M STYLE K Inhaltsverzeichnis 1 General information...

More information

Mounting System MCG 1.1 Membrane-Connected Glass. System description

Mounting System MCG 1.1 Membrane-Connected Glass. System description Mounting System MCG 1.1 Membrane-Connected Glass System description SUNOVA MCG 1.1 System Fields of application: Not suitable for: (please inquire for other SUNOVA systems) The SUNOVA MCG system is a lightweight

More information

ifix INSTALLATION MANUAL PV flat roof installation system Version

ifix INSTALLATION MANUAL PV flat roof installation system Version ifix PV flat roof installation system INSTALLATION MANUAL Version 2012-09-06 ifix Installation Manual Version 2012-09-06 Seite 1 Table of contents Table of contents... 1 Special characteristics of ifix...

More information

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate Photovoltaic Mounting Systems Assembly Instructions PITCHED ROOF for roofing tiles, plain tiles and slate S:FLEX GmbH 09/2017 / design and engineering is subject to change 1 Index 1 Introduction 1.1 Intended

More information

Installer Guide. Item

Installer Guide. Item Installer Guide Item 17392-01 Required tools and fixings Electric drill (non-impact setting) T-30 Torq bit (wedge type) 8mm hex socket Pozi head drill bit Tape measure Pencil/pen Hammer Tin snips Angle

More information

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

MOUNTING SYSTEMS APPLICATIONS OVERVIEW MOUNTING SYSTEMS APPLICATIONS OVERVIEW Catalogue Verion June 2013 TRITEC MOUNTING SYSTEMS: OVERVIEW OF APPLICATIONS I. Pitched Roof: Roof-Top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND on tiles

More information

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM EN mounting system for uninsulated pitched roof Bitumen / EPDM for solar panels portrait / landscape setup ESDEC BV 2015 TABLE OF CONTENT 1. Introduction 1 2.

More information

mounting systems applications overview

mounting systems applications overview mounting systems applications overview catalogue version January 2015 tritec mounting systems: overview of applications i. pitched roof: roof-top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND

More information

Installation Instruction for DMEGC Photovoltaic Module

Installation Instruction for DMEGC Photovoltaic Module Content 1. PURPOSE... 1 1.1 GENERAL TERM... 1 2. SAFETY PRECAUTIONS FOR SOLAR PV SYSTEM INSTALLATION... 3 3. INSTALLATION CONDITION... 4 3.1 INSTALLATION LOCATION AND WORKING CONDITIONS... 4 3.2 SELECTION

More information

S 01 Modules WC I-IlI

S 01 Modules WC I-IlI S 01 Modules WC I-IlI GB Installation instructions GB S 01 Contents 1 Introduction... 4 About these instructions... 4 Explanation of the symbols and signal words used... 4 Target group... 4 HEWI Support...

More information

2019 V1 SERAPHIM DG PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

2019 V1 SERAPHIM DG PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG 2019 V1 SERAPHIM DG PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG ROAD NO. 1-2. TELEPHONE: +86-519-88776028 FAX: +86-519-88786181

More information

Installation instructions

Installation instructions Installation instructions IBC AeroFix Date: 30-Jun-2015 1 Contents 0. Introduction... 3 01. Tool list... 4 02. General information, standards and regulations... 4 03. System variants... 8 04. Technical

More information

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

Parabond 600 Elastic adhesive sealant with high initial bonding strength. Parabond 600 Elastic adhesive sealant with high initial bonding strength. Product: Parabond 600 is an MS-polymer based, durable and fast curing elastic adhesive. Applications: Parabond 600 has a very high

More information

Parabond 600 Elastic glue and adhesive with extremely high initial bonding

Parabond 600 Elastic glue and adhesive with extremely high initial bonding Parabond 600 Elastic glue and adhesive with extremely high initial bonding Product: Parabond 600 is a high-quality, quickly drying, durable MS-Polymer based elastic glue and adhesive with a very high initial

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720

More information

HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION

HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION INSTALLATION INSTRUCTIONS ENERGY AND SANITARY SYSTEMS Installation requirements General requirements The free-standing installation set is to be used for

More information

Installation Instructions

Installation Instructions S o l a r R o o f i n g Installation Instructions Apollo Tile II Installation Instructions Key... 3 Safety Precautions... 3 Installation Limitations... 4 Installation Requirements... 5 Recommended Tools

More information

aquapanel InstallatIon GuIde

aquapanel InstallatIon GuIde Installation Guide AQUAPANEL BEFORE YOU START It s a good idea to stand the AQUAPANEL sheets in the area for 2 days prior to cutting and installing, to allow the sheets to breathe and reach moisture equilibrium.

More information

Mounting instructions

Mounting instructions Mounting instructions novotegra for tile roofs top-fix I TABLE OF CONTENTS 1 Notes... 1 2 Maintenance of the mounting system... 3 3 novotegra for tile roofs... 3 4 System components, tools and equipment...

More information

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West Exposition East West CONTENTS 1 Notes on the Sika SolarMount 1 system (Exposition East West) for PV solar arrays 3 2 Setting up on site 3 3 Required Tools for mounting Sika SolarMount 1 to Sika roofing

More information

Infix ProLine Installation manual

Infix ProLine Installation manual Infix ProLine Installation manual 80-0007 Table of contents Introduction. Overview. Intended use. Standards and technical directives.4 About this manual Theta Only the sun gets in Safety. Basic safety

More information

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

Parabond 600 Elastic adhesive sealant with high initial bonding strength. Parabond 600 Elastic adhesive sealant with high initial bonding strength. Product: Parabond 600 is an MS-polymer based, durable and fast curing elastic adhesive. Applications: Parabond 600 has a very high

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

YINGLI SOLAR TWINMAX MODULES Installation and User Manual YINGLI SOLAR TWINMAX MODULES Installation and User Manual Revision Date Aug 3rd, 2016 Applicable for IEC certified products This manual applies to photovoltaic TwinMAX modules ( TwinMAX modules, also commonly

More information

PHOTOVOLTAIC SYSTEMS. Syllabus. 1 Photovoltaic systems

PHOTOVOLTAIC SYSTEMS. Syllabus. 1 Photovoltaic systems PHOTOVOLTAIC SYSTEMS Syllabus 1 Photovoltaic systems 1 Identify typical photovoltaic (PV) installations a) grid connected b) building integrated c) non-integrated 2 State typical expected outputs of a

More information

BiPv 2-11 Mounting Instructions

BiPv 2-11 Mounting Instructions BiPv 2-11 Mounting Instructions In-roof system for unframed modules General information The in-roof BiPv 2-11 system was designed for frameless modules and can be applied as a defi ned section of an existing

More information

Radiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT

Radiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT Radiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT 2-2012 The PV-RoofTopRac System has been developed as a universal system for roof-mounting on pitched roofs.

More information

Mounting systems for solar technology

Mounting systems for solar technology Mounting systems for solar technology ASSEMBLY INSTRUCTIONS SPEEDRAIL system GB Table of contents TABLE OF CONTENTS THE COMPANY SAFETY REGULATIONS MATERIALS REQUIRED TOOLS REQUIRED ASSEMBLY 2 3 4 5 7 8

More information

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS GUIDE FOR TIMBER AND CONCRETE FLOORS EDITION: APRIL 2016 IMPORTANT: This guide is for the installation of a Step Up shower base on a timber or concrete floor. If you require a walk in (flush with floor)

More information

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG 016 V1 SERAPHIM ECLIPSE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG ROAD NO. 1-. TELEPHONE: +86-519-8877608 FAX: +86-519-88786181 MAILBOX: info@seraphim-energy.com

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS

FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS DESCRIPTION FrostGuard 120 V preassembled self-regulating heating

More information

Sarnavap 5000E SA Vapour Control Layer

Sarnavap 5000E SA Vapour Control Layer Roofing Product Data Sheet Edition 09.2008 Identification no. 02 09 01 05 402 0 000007 Version no. 02 Sarnavap 5000E SA Vapour Control Layer Product Description Sarnavap 5000E SA is a multi-layer self-adhesive

More information

INSTALLATION INSTRUCTIONS ENGLISH

INSTALLATION INSTRUCTIONS ENGLISH INSTALLATION INSTRUCTIONS ENGLISH Safety instructions 04 General notes 07 Material & tool requirements 08 System overview 10 installation of CREODUR 11 Maintenance 22 04 INTENDED USE Creotecc mounting

More information

Mounting instructions. novotegra for trapezoidal metal - roof parallel

Mounting instructions. novotegra for trapezoidal metal - roof parallel Mounting instructions novotegra for trapezoidal metal - roof parallel I TABLE OF CONTENTS 1 Notes... 1 2 Maintenance of the mounting system... 3 3 novotegra for trapezoidal metal - roof parallel... 3 4

More information

Clearly Solar. Installation Instructions. Solar Thermal Flat Plate Collector. Vertical On-roof mounting SHV

Clearly Solar. Installation Instructions. Solar Thermal Flat Plate Collector. Vertical On-roof mounting SHV Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Vertical On-roof mounting 15-75 SHV 2.3 www.glow-worm.co.uk 1 Guarantee Registration These Clearly Solar Flat Plate collectors

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS ULEB 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS

More information

00MK-MA0160-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Little Plan and Little Plan Light systems, for corrugated sheet metal roof

00MK-MA0160-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Little Plan and Little Plan Light systems, for corrugated sheet metal roof 00MK-MA0160-EN00 Mounting System ASSEMBLY INSTRUCTIONS Little Plan and Little Plan Light systems, for corrugated sheet metal roof Rev.02 November 2014 Table of contents General instructions 2 General safety

More information

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver. The Knife Edge Cove is a modular lighting system consisting of two parts: 1- An aluminum fixture housing extrusion 2- Drop-in lighting modules The fixture will provide a continuous knife edge architectural

More information

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan) TOOLKIT DOCUMENT #7 Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan) This document has two sections. Neither section is all-inclusive

More information

Table of Contents. Sunslates6 TM Installation Manual. Aesthetic Green Power, Inc. Page 1 of 15 REV /25/13

Table of Contents. Sunslates6 TM Installation Manual. Aesthetic Green Power, Inc. Page 1 of 15 REV /25/13 1 Table of Contents 1. About this Installation Manual... 2 2. Sunslates6 TM Specifications... 2 2.1 Sunslates6 TM Physical Specifications... 2 2.2 Sunslates6 TM Electrical Specifications... 3 3. Sunslates6

More information

Installation Instruction photovoltaic modules E-PV 250W on the flat roof or fundation 10/2013 Get acquainted before the installation.

Installation Instruction photovoltaic modules E-PV 250W on the flat roof or fundation 10/2013 Get acquainted before the installation. Installation Instruction photovoltaic modules E-PV 250W on the flat roof or fundation 10/2013 Get acquainted before the installation. 1. General information Lightning Protection System In case of LPS we

More information

installation instructions English

installation instructions English www.creotecc.com installation instructions English Safety instructions 04 General notes 07 Material & tool requirements 08 System overview 10 installation of CREODUR 11 Maintenance 22 04 INTENDED USE

More information

HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION

HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION INSTRUCTION MANUAL ENERGY AND SANITARY SYSTEMS Installation requirements General requirements The free-standing installation set is to be used or installing

More information

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170 Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170 The ezrack has been developed as a universal system for roof-mounting on pitched roofs. The use of patented

More information

3 500-Series Polyurethane Products:

3 500-Series Polyurethane Products: 3 500-Series Polyurethane Products: 3M Polyurethane Construction Sealant 525 3M Polyurethane Construction Sealant 535 3M Polyurethane Sealant 540 3M Polyurethane Adhesive Sealant Fast Cure 550 3M Polyurethane

More information

Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal On-roof mounting SRH 2.3

Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal On-roof mounting SRH 2.3 Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal On-roof mounting 15-75 SRH 2.3 www.glow-worm.co.uk 1 Guarantee Registration These Clearly Solar Flat Plate collectors

More information

3 700-Series Hybrid Products:

3 700-Series Hybrid Products: 3 700-Series Hybrid Products: 3M 3M 3M Technical Data December, 2009 Product Description 3M 700-Series Hybrid Sealant and Hybrid Adhesive Sealant products are one component, moisture curing products which

More information

Rotec flange bonding, two component adhesive system

Rotec flange bonding, two component adhesive system Note! This system is to be used with type A Fixed and Stub Flanges only. Rotec Adhesive Injection System Location of drillings for gluing flanges The Rotec Injection Adhesive System for bonding of Rotec

More information

AluGrid100+ Mounting Instructions. AluGrid+ lower module-bearing profile. AluGrid+ fastening clamp for module-bearing profile

AluGrid100+ Mounting Instructions. AluGrid+ lower module-bearing profile. AluGrid+ fastening clamp for module-bearing profile AluGrid00+ Mounting Instructions Module clamp Module-bearing profile Fastening clamp Module-bearing support AluGrid+ lower module-bearing profile AluGrid+ fastening clamp for module-bearing profile End

More information

INSTALLATION INSTRUCTION AEROCOMPACT S5

INSTALLATION INSTRUCTION AEROCOMPACT S5 INSTALLATION INSTRUCTION AEROCOMPACT S5 Flat-roof mount for PV installations IN. AEs5 US 2014.1 the unbeatable flat-roof solution YOUR BIG ADVANTAGE + 25 years product warranty + Best price value available

More information

Rack-in-a-BoxTM INSTALLATION MANUAL

Rack-in-a-BoxTM INSTALLATION MANUAL INSTALLATION MANUAL TM 1.0 INTRODUCTION 3 2.0 PRODUCT RANGE 4 2.1 Systems 4 2.2 Accessories 4 3.0 PREPARATION FOR INSTALLATION 5 3.1 Applications 5 3.2 Tools for Installation 5 3.3 Additional Materials

More information

Fascia Systems. oofing 7.1

Fascia Systems. oofing 7.1 Systems oofing 7.1 TremLock TM A Pre-engineered, Non-Penetrating Metal Edge System oofing TremLock TM Pre-engineered, Non-penetrating Metal Edge System The TremLock is a pre-engineered, non-penetrating

More information

a-si/μcsi Tandem Module Installation Manual Macsun Solar Energy Technology Co., Limited Applied to MS-SDXX

a-si/μcsi Tandem Module Installation Manual Macsun Solar Energy Technology Co., Limited Applied to MS-SDXX a-si/μcsi Tandem Module Installation Manual Macsun Solar Energy Technology Co., Limited 2014.1.20 Applied to MS-SDXX 1. 2. 3. 4. 5. CONTENT PURPOSE... 2 WARNING... 2 SCOPE... 2 RESPONSIBILITY... 2 INSTALLATION...

More information

Valance Installation. For Units with Beam Style Coils

Valance Installation. For Units with Beam Style Coils Valance Installation For Units with Beam Style Coils 1. Before installation of valance units, determine if drapes are to be used, or if any wall construction will protrude into room. If either drapes or

More information

Mounting System MCG 3.0 Membrane-Connected Glass. System description

Mounting System MCG 3.0 Membrane-Connected Glass. System description Mounting System MCG 3.0 Membrane-Connected Glass System description SUNOVA MCG 3.0 System Fields of application: Not suitable for: (please inquire for other SUNOVA systems) The SUNOVA MCG 3.0 system is

More information

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions Assembly Manual 6x5 PATENTS ARE PENDING Building Dimensions Approximate Size Storage Area Exterior Dimensions Interior Dimensions Roof Edge to Roof Edge Wall to Wall Sq. Ft. Cu. Ft. Width Depth Height

More information

SRP-AirOutshield UV Issued:

SRP-AirOutshield UV Issued: SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing

More information

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2 Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2 The Solar Tripod System has been developed as a universal system for roof-mounting on flat roofs. The use of patented

More information

1. What are the benefits of Decorative Wall Panels? 2. Where can these decorative panels are used? 3. Are the panels waterproof?

1. What are the benefits of Decorative Wall Panels? 2. Where can these decorative panels are used? 3. Are the panels waterproof? 1. What are the benefits of Decorative Wall Panels? Decorative Wall Panels are made from precision extruded PVC and decorated with unique designs ranging from marble, onyx to wood grain patterns. Other

More information

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL

More information

SpeedTrace Roof & Gutter Pre-Assembled Self-Regulating Heating Cable

SpeedTrace Roof & Gutter Pre-Assembled Self-Regulating Heating Cable SpeedTrace Roof & Gutter Pre-Assembled Self-Regulating Heating Cable For Snow and Ice Melting on Roofs and in Gutters and Downspouts Instruction Manual Read and understand this entire manual before installing

More information

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge Assembly Manual 8x5 PATENTS ARE PENDING Approximate Size 7980303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth

More information

Layher. Keder Roof and Keder Hall. More Possibilities. The Scaffolding System. Layher Keder Roof and Keder Hall Instructions for Assembly and Use

Layher. Keder Roof and Keder Hall. More Possibilities. The Scaffolding System. Layher Keder Roof and Keder Hall Instructions for Assembly and Use Layher Keder Roof and Keder Hall Instructions for Assembly and Use Certification as per DIN ISO 9001/EN 29 001 by TÜV-CERT Keder Roof and Keder Hall Layher More Possibilities. The Scaffolding System. CONTENTS

More information

SOLITEX MENTO. Roof Underlays. Waterproof Weathertight. Windproof Durable Y E S P L E A S E!

SOLITEX MENTO. Roof Underlays. Waterproof Weathertight. Windproof Durable Y E S P L E A S E! Roof Underlays Waterproof Weathertight... optimum protection against mould and condensation in your construction Windproof Durable Appraisal No.855 [2014] 3000 Roof Underlay Healthy Indoor Air Y E S P

More information

WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS

WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS EDITION: APRIL 2016 IMPORTANT: If you require a Walk In shower base for timber floors, please go to our support page at www.hydroblok.com.au IMPORTANT:

More information

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS I N SULROCK FIRE RATED METAL PANELS GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS 1. GENERAL 1.1. Summary Fire-rated panels as shown on the drawings shall be INSULROCK brand panels as supplied by Green

More information

Leading in integration for partial- and full roofs: Photovoltaic in-roof mounting system Solrif by Schweizer.

Leading in integration for partial- and full roofs: Photovoltaic in-roof mounting system Solrif by Schweizer. Leading in integration for partial- and full roofs: Photovoltaic in-roof mounting system Solrif by Schweizer. Aesthetically pleasing yet powerful: Photovoltaic in-roof mounting system Solrif by Schweizer.

More information

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth

More information

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage

More information

6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware

6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware Tools/materials you might need for proper installation 6D galvanized screws 100% silicone caulking caulking gun acrylic latex caulk shims tape measure 1/8 drill bit Phillips screw driver cardboard china

More information

S4 Taifun Installation Manual

S4 Taifun Installation Manual CEIL ING LIGHTING AMBIENCE S4 Taifun Installation Manual GENERAL INFORMATION GENERAL INFORMATION This assembly manual addresses all metal ceilings manufactured by durlum. The different sections describe

More information

Model No. BWTDWFK-TRIFLO.

Model No. BWTDWFK-TRIFLO. Model No. BWTDWFK-TRIFLO www.bwt-uk.co.uk Before you start This tap is suitable for use at water supply pressures of 2 bar (min.) to 5 bar (max.). This product must be connected to the water supply in

More information

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual SECURE. UNIVERSAL. MOUNTING Tilt Kit Installation Manual 1.0 INTRODUCTION... 3 2.0 KITS / PRODUCT RANGE... 4 2.1 Leg Kits... 4 2.2 Rail Kits... 4 3.0 PREPARATION FOR INSTALLATION... 5 3.1 Applications...

More information

TallSlate TM with BITERS Installation Manual

TallSlate TM with BITERS Installation Manual PLEASE READ THIS GUIDE COMPLETELY BEFORE INSTALLING OR USING THE SOLAR ELECTRIC MODULES Disclaimer of Liability...2 General Information...2 General Safety...2 TallSlate TM Specifications...3 Requirements

More information

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description January, 2009 Sarnafil TS 77-15 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics / Advantages Approval / Standards Sarnafil TS 77-15 (thickness 1.5 mm) is

More information

INSTALLATION INSTRUCTIONS ENGLISH

INSTALLATION INSTRUCTIONS ENGLISH INSTALLATION INSTRUCTIONS ENGLISH Safety instructions 04 General notes 07 Material & tool requirements 08 System overview 10 installation of ALUTEC 12 Maintenance 27 04 INTENDED USE Creotecc mounting

More information

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas. SPECIFICATION FOR PROTECTO WRAP AFM-WM FOR INTERNAL WET AREAS BRANZ Appraisal Certificate # 461 (2010) Internal wet areas AFM/WM INTERNAL 0104 Page 1 AFM-WM INTERNAL SPECIFICATION PRODUCT DESCRIPTION Anti

More information

DuraComp Composite Decking Installation Guide. Hidden Plastic Clip Fixing

DuraComp Composite Decking Installation Guide. Hidden Plastic Clip Fixing Composite Decking Installation Guide Hidden Plastic Clip Fixing Table of Contents SECTION ONE: General Information Site Preparation......2 Site Storage.....2 Safety. 2 Tools....2 Foundation & Sub Structure.2

More information