INTERIOR FINISHES CHAPTER 8
|
|
- Shawn Hodge
- 6 years ago
- Views:
Transcription
1 CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL Scope. Provisions of this chapter shall govern the use of materials used as interior finishes, trim and decorative materials Interior wall and ceiling finish. The provisions of Section 803 shall limit the allowable fire performance and smoke development of interior wall and ceiling finish materials based on occupancy classification Interior floor finish. The provisions of Section 804 shall limit the allowable fire performance of interior floor finish materials based on occupancy classification. [F] Decorative materials and trim. Decorative materials and trim shall be restricted by combustibility and the flame propagation performance criteria of NFPA 701, in accordance with Section Applicability. For buildings in flood hazard areas as established by the Flood Plain Administrator, interior finishes, trim and decorative materials below the elevation required by Section 1612 shall be flood-damage-resistant materials Application. Combustible materials shall be permitted to be used as finish for walls, ceilings, floors and other interior surfaces of buildings Windows. Show windows in the exterior walls of the first story above grade plane shall be permitted to be of wood or of unprotected metal framing Foam plastics. Foam plastics shall not be used as interior finish except as provided in Section Foam plastics shall not be used as interior trim except as provided in Section or This section shall apply both to exposed foam plastics and to foam plastics used in conjunction with a textile or vinyl facing or cover. SECTION 802 DEFINITIONS Definitions. The following terms are defined in Chapter 2: EXPANDED VINYL WALL COVERING. FLAME SPREAD. FLAME SPREAD INDEX. INTERIOR FINISH. INTERIOR FLOOR FINISH. INTERIOR FLOOR-WALL BASE. INTERIOR WALL AND CEILING FINISH. SITE-FABRICATED STRETCH SYSTEM. SMOKE-DEVELOPED INDEX. TRIM. SECTION 803 WALL AND CEILING FINISHES General. Interior wall and ceiling finish materials shall be classified for fire performance and smoke development in accordance with Section or , except as shown in Sections through Materials tested in accordance with Section shall not be required to be tested in accordance with Section Interior wall and ceiling finish materials. Interior wall and ceiling finish materials shall be classified in accordance with ASTM E 84 or UL 723. Such interior finish materials shall be grouped in the following classes in accordance with their flame spread and smoke-developed indexes. Class A: = Flame spread index 0-25; smoke-developed index Class B: = Flame spread index 26-75; smoke-developed index Class C: = Flame spread index ; smoke-developed index Exception: Materials tested in accordance with Section Room corner test for interior wall or ceiling finish materials. Interior wall or ceiling finish materials shall be permitted to be tested in accordance with NFPA 286. Interior wall or ceiling finish materials tested in accordance with NFPA 286 shall comply with Section Acceptance criteria for NFPA 286. The interior finish shall comply with the following: 1. During the 40 kw exposure, flames shall not spread to the ceiling. 2. The flame shall not spread to the outer extremity of the sample on any wall or ceiling. 3. Flashover, as defined in NFPA 286, shall not occur. 4. The peak heat release rate throughout the test shall not exceed 800 kw. 5. The total smoke released throughout the test shall not exceed 1,000 m Room corner test for textile wall coverings and expanded vinyl wall coverings. Textile wall coverings and expanded vinyl wall coverings shall meet the criteria of Section when tested in the manner intended for use in accordance with the Method B protocol of NFPA 265 using the product-mounting system, including adhesive OREGON STRUCTURAL SPECIALTY CODE 207
2 Acceptance criteria for NFPA 265. The interior finish shall comply with the following: 1. During the 40 kw exposure, flames shall not spread to the ceiling. 2. The flame shall not spread to the outer extremities of the samples on the 8-foot by 12-foot (203 by 305 mm) walls. 3. Flashover, as defined in NFPA 265, shall not occur. 4. The total smoke released throughout the test shall not exceed 1,000 m Acceptance criteria for textile and expanded vinyl wall or ceiling coverings tested to ASTM E 84 or UL 723. Textile wall and ceiling coverings and expanded vinyl wall and ceiling coverings shall have a Class A flame spread index in accordance with ASTM E 84 or UL 723 and be protected by an automatic sprinkler system installed in accordance with Section or Test specimen preparation and mounting shall be in accordance with ASTM E Thickness exemption. Materials having a thickness less than inch (0.9 mm) applied directly to the surface of walls or ceilings shall not be required to be tested Heavy timber exemption. Exposed portions of structural members complying with the requirements for buildings of Type IV construction in Section shall not be subject to interior finish requirements Foam plastics. Foam plastics shall not be used as interior finish except as provided in Section This section shall apply both to exposed foam plastics and to foam plastics used in conjunction with a textile or vinyl facing or cover Textile wall coverings. Where used as interior wall finish materials, textile wall coverings, including materials having woven or nonwoven, napped, tufted, looped or similar surface and carpet and similar textile materials, shall be tested in the manner intended for use, using the product mounting system, including adhesive, and shall comply with the requirements of Section , or Textile ceiling coverings. Where used as interior ceiling finish materials, textile ceiling coverings, including materials having woven or nonwoven, napped, tufted, looped or similar surface and carpet and similar textile materials, shall be tested in the manner intended for use, using the product mounting system, including adhesive, and shall comply with the requirements of Section or Expanded vinyl wall coverings. Where used as interior wall finish materials, expanded vinyl wall coverings shall be tested in the manner intended for use, using the product mounting system, including adhesive, and shall comply with the requirements of Section , or Expanded vinyl ceiling coverings. Where used as interior ceiling finish materials, expanded vinyl ceiling coverings shall be tested in the manner intended for use, using the product mounting system, including adhesive, and shall comply with the requirements of Section or Interior finish requirements based on group. Interior wall and ceiling finish shall have a flame spread index not greater than that specified in Table for the group and location designated. Interior wall and ceiling finish materials tested in accordance with NFPA 286 and meeting the acceptance criteria of Section , shall be permitted to be used where a Class A classification in accordance with ASTM E 84 or UL 723 is required Stability. Interior finish materials regulated by this chapter shall be applied or otherwise fastened in such a manner that such materials will not readily become detached where subjected to room temperatures of 200 F (93 C) for not less than 30 minutes Application of interior finish materials to fireresistance-rated or noncombustible building elements. Where interior finish materials are applied on walls, ceilings or structural elements required to have a fire-resistance rating or to be of noncombustible construction, they shall comply with the provisions of this section Direct attachment and furred construction. Where walls and ceilings are required by any provision in this code to be of fire-resistance-rated or noncombustible construction, the interior finish material shall be applied directly against such construction or to furring strips not exceeding 1 3 / 4 inches (44 mm), applied directly against such surfaces Furred construction. If the interior finish material is applied to furring strips, the intervening spaces between such furring strips shall comply with one of the following: 1. Be filled with material that is inorganic or noncombustible; 2. Be filled with material that meets the requirements of a Class A material in accordance with Section or ; or 3. Be fireblocked at a maximum of 8 feet (2438 mm) in every direction in accordance with Section Set-out construction. Where walls and ceilings are required to be of fire-resistance-rated or noncombustible construction and walls are set out or ceilings are dropped distances greater than specified in Section , Class A finish materials, in accordance with Section or , shall be used. 1. Where interior finish materials are protected on both sides by an automatic sprinkler system in accordance with Section or Where interior finish materials are attached to noncombustible backing or furring strips installed as specified in Section OREGON STRUCTURAL SPECIALTY CODE
3 GROUP TABLE INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY k Interior exit stairways, interior exit ramps and exit passageways a, b SPRINKLERED l Corridors and enclosure for exit access stairways and exit access ramps Rooms and enclosed spaces c Interior exit stairways, interior exit ramps and exit passageways a, b NONSPRINKLERED Corridors and enclosure for exit access stairways and exit access ramps Rooms and enclosed spaces c A-1 & A-2 B B C A A d B e A-3 f, A-4, A-5 B B C A A d C B, E, M, R-1 B C C A B C R-4 B C C A B B F C C C B C C H B B C g A A B I-1 B C C A B B I-2 B B B h, i A A B I-3 A A j C A A B I-4 B B B h, i A A B R-2 C C C B B C R-3 C C C C C C S C C C B B C U No restrictions No restrictions For SI: 1 inch = 25.4 mm, 1 square foot = m 2. a. Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and fireblocked as required by Section b. In other than Group I-2 occupanicies in buildings less than three stories above grade plane of other than Group I-3, Class B interior finish for nonsprinklered buildings and Class C interior finish for sprinklered buildings shall be permitted in interior exit stairways and ramps. c. Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire-resistance rating is required for structural elements, the enclosing partitions shall extend from the floor to the ceiling. Partitions that do not comply with this shall be considered enclosing spaces and the rooms or spaces on both sides shall be considered one. In determining the applicable requirements for rooms and enclosed spaces, the specific occupancy thereof shall be the governing factor regardless of the group classification of the building or structure. d. Lobby areas in Group A-1, A-2 and A-3 occupancies shall not be less than Class B materials. e. Class C interior finish materials shall be permitted in places of assembly with an occupant load of 300 persons or less. f. For places of religious worship, wood used for ornamental purposes, trusses, paneling or chancel furnishing shall be permitted. g. Class B material is required where the building exceeds two stories. h. Class C interior finish materials shall be permitted in administrative spaces. i. Class C interior finish materials shall be permitted in rooms with a capacity of four persons or less. j. Class B materials shall be permitted as wainscotting extending not more than 48 inches above the finished floor in corridors and exit access stairways and ramps. k. Finish materials as provided for in other sections of this code. l. Applies when protected by an automatic sprinkler system installed in accordance with Section or Hangers and assembly members. The hangers and assembly members of such dropped ceilings that are below the horizontal fire-resistance rated floor or roof assemblies shall be of noncombustible materials. The construction of each set-out wall and horizontal fire-resistance rated floor or roof assembly shall be of fire-resistance-rated construction as required elsewhere in this code. Exception: In Types III and V construction, fireretardant-treated wood shall be permitted for use as hangers and assembly members of dropped ceilings Heavy timber construction. Wall and ceiling finishes of all classes as permitted in this chapter that are installed directly against the wood decking or planking of Type IV construction or to wood furring strips applied directly to the wood decking or planking shall be fireblocked as specified in Section Materials. An interior wall or ceiling finish material that is not more than ¼ inch (6.4 mm) thick shall be applied directly onto the wall, ceiling or structural element without the use of furring strips and shall not be suspended away from the building element to which it is applied. 1. Noncombustible interior finish materials. 2. Materials that meet the requirements of Class A materials in accordance with Section or where the qualifying tests were made with the material furred out from the noncombus OREGON STRUCTURAL SPECIALTY CODE 209
4 tible backing shall be permitted to be used with furring strips. 3. Materials that meet the requirements of Class A materials in accordance with Section or where the qualifying tests were made with the material suspended away from the noncombustible backing shall be permitted to be used suspended away from the building element High-density Polyethylene (HDPE) and Polypropylene (PP). Where high-density polyethylene or polypropylene is used as an interior finish it shall comply with Section Site-fabricated stretch systems. Where used as interior wall or interior ceiling finish materials, site-fabricated stretch systems containing all three components described in the definition in Section 802 shall be tested in the manner intended for use, and shall comply with the requirements of Section or If the materials are tested in accordance with ASTM E 84 or UL 723, specimen preparation and mounting shall be in accordance with ASTM E SECTION 804 INTERIOR FLOOR FINISH General. Interior floor finish and floor covering materials shall comply with Sections through Exception: Floor finishes and coverings of a traditional type, such as wood, vinyl, linoleum or terrazzo, and resilient floor covering materials that are not comprised of fibers Classification. Interior floor finish and floor covering materials required by Section to be of Class I or II materials shall be classified in accordance with NFPA 253. The classification referred to herein corresponds to the classifications determined by NFPA 253 as follows: Class I, 0.45 watts/cm 2 or greater; Class II, 0.22 watts/cm 2 or greater Testing and identification. Interior floor finish and floor covering materials shall be tested by an agency in accordance with NFPA 253 and identified by a hang tag or other suitable method so as to identify the manufacturer or supplier and style, and shall indicate the interior floor finish or floor covering classification according to Section Carpettype floor coverings shall be tested as proposed for use, including underlayment. Test reports confirming the information provided in the manufacturer's product identification shall be furnished to the building official upon request Interior floor finish requirements. Interior floor covering materials shall comply with Sections and and interior floor finish materials shall comply with Section Test requirement. In all occupancies, interior floor covering materials shall comply with the requirements of the DOC FF-1 pill test (CPSC 16 CFR Part 1630) or with ASTM D Minimum critical radiant flux. In all occupancies, interior floor finish and floor covering materials in enclosures for stairways and ramps, exit passageways, corridors and rooms or spaces not separated from corridors by partitions extending from the floor to the underside of the ceiling shall withstand a minimum critical radiant flux. The minimum critical radiant flux shall not be less than Class I in Groups I-1, I-2 and I-3 and not less than Class II in Groups A, B, E, H, I- 4, M, R-1, R-2 and S. Exception: Where a building is equipped throughout with an automatic sprinkler system in accordance with Section or , Class II materials are permitted in any area where Class I materials are required, and materials complying with DOC FF-1 pill test (CPSC 16 CFR Part 1630) or with ASTM D 2859 are permitted in any area where Class II materials are required. SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION Application. Combustible materials installed on or embedded in floors of buildings of Type I or II construction shall comply with Sections through Exception: Stages and platforms constructed in accordance with Sections and 410.4, respectively Subfloor construction. Floor sleepers, bucks and nailing blocks shall not be constructed of combustible materials, unless the space between the fire-resistancerated floor assembly and the flooring is either solidly filled with noncombustible materials or fireblocked in accordance with Section 718, and provided that such open spaces shall not extend under or through permanent partitions or walls Wood finish flooring. Wood finish flooring is permitted to be attached directly to the embedded or fireblocked wood sleepers and shall be permitted where cemented directly to the top surface of fire-resistancerated floor assemblies or directly to a wood subfloor attached to sleepers as provided for in Section Insulating boards. Combustible insulating boards not more than 1 / 2 inch (12.7 mm) thick and covered with finish flooring are permitted where attached directly to a noncombustible floor assembly or to wood subflooring attached to sleepers as provided for in Section SECTION 806 DECORATIVE MATERIALS AND TRIM [F] General requirements. In occupancies in Groups A, E, I and R-1 and dormitories in Group R-2, curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall meet the flame propagation performance criteria of NFPA 701 in accordance with Section or be noncombustible. 1. Curtains, draperies, hangings and other decorative materials suspended from walls of sleeping units and dwelling units in dormitories in Group R-2 pro OREGON STRUCTURAL SPECIALTY CODE
5 tected by an approved automatic sprinkler system installed in accordance with Section and such materials are limited to not more than 50 percent of the aggregate area of walls. 2. Decorative materials, including, but not limited to, photographs and paintings in dormitories in Group R-2 where such materials are of limited quantities such that a hazard of fire development or spread is not present. In Groups I-1 and I-2, combustible decorative materials shall meet the flame propagation criteria of NFPA 701 unless the decorative materials, including, but not limited to, photographs and paintings, are of such limited quantities that a hazard of fire development or spread is not present. In Group I-3, combustible decorative materials are prohibited. Fixed or movable walls and partitions, paneling, wall pads and crash pads applied structurally or for decoration, acoustical correction, surface insulation or other purposes shall be considered interior finish if they cover 10 percent or more of the wall or of the ceiling area, and shall not be considered decorative materials or furnishings. In Group B and M occupancies, fabric partitions suspended from the ceiling and not supported by the floor shall meet the flame propagation performance criteria in accordance with Section and NFPA 701 or shall be noncombustible. [F] Noncombustible materials. The permissible amount of noncombustible decorative material shall not be limited. [F] Combustible decorative materials. The permissible amount of decorative materials meeting the flame propagation performance criteria of NFPA 701 shall not exceed 10 percent of the specific wall or ceiling area to which it is attached. 1. In auditoriums in Group A, the permissible amount of decorative material meeting the flame propagation performance criteria of NFPA 701 shall not exceed 75 percent of the aggregate wall area where the building is equipped throughout with an automatic sprinkler system in accordance with Section and where the material is installed in accordance with Section The amount of fabric partitions suspended from the ceiling and not supported by the floor in Group B and M occupancies shall not be limited. [F] Acceptance criteria and reports. Where required by Section 806.1, decorative materials shall be tested by an agency and meet the flame propagation performance criteria of NFPA 701 or such materials shall be noncombustible. Reports of test results shall be prepared in accordance with NFPA 701 and furnished to the building official upon request. [F] Foam plastic. Foam plastic used as trim in any occupancy shall comply with Section [F] Pyroxylin plastic. Imitation leather or other material consisting of or coated with a pyroxylin or similarly hazardous base shall not be used in Group A occupancies. [F] Interior trim. Material, other than foam plastic used as interior trim, shall have a minimum Class C flame spread and smoke-developed index when tested in accordance with ASTM E 84 or UL 723, as described in Section Combustible trim, excluding handrails and guardrails, shall not exceed 10 percent of the specific wall or ceiling area to which it is attached. [F] Interior floor-wall base. Interior floor-wall base that is 6 inches (152 mm) or less in height shall be tested in accordance with Section and shall not be less than Class II. Where a Class I floor finish is required, the floorwall base shall be Class I. Exception: Interior trim materials that comply with Section SECTION 807 INSULATION Insulation. Thermal and acoustical insulation shall comply with Section 720. SECTION 808 ACOUSTICAL CEILING SYSTEMS Acoustical ceiling systems. The quality, design, fabrication and erection of metal suspension systems for acoustical tile and lay-in panel ceilings in buildings or structures shall conform with generally accepted engineering practice, the provisions of this chapter and other applicable requirements of this code Materials and installation. Acoustical materials complying with the interior finish requirements of Section 803 shall be installed in accordance with the manufacturer's recommendations and applicable provisions for applying interior finish Suspended acoustical ceilings. Suspended acoustical ceiling systems shall be installed in accordance with the provisions of ASTM C 635 and ASTM C Fire-resistance-rated construction. Acoustical ceiling systems that are part of fire-resistancerated construction shall be installed in the same manner used in the assembly tested and shall comply with the provisions of Chapter OREGON STRUCTURAL SPECIALTY CODE 211
6 OREGON STRUCTURAL SPECIALTY CODE
HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 301
CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 8 INTERIOR FINISHES (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and
More informationINTERIOR FINISHES CHAPTER 8
CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL 801.1 Scope. Provisions of this chapter shall govern the use of materials used as interior finishes, trim and decorative materials. 801.2 Interior wall and
More informationINTERIOR FINISHES CHAPTER 8
CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL 801.1 Scope. Provisions of this chapter shall govern the use of materials used as interior finishes, trim and decorative materials. 801.1.1 Interior finishes.
More informationINTERIOR FINISHES CHAPTER 8 SECTION 801 GENERAL
CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL 801.1 Scope. Provisions of this chapter shall govern the use of materials used as interior finishes, trim and decorative materials. 801.1.1 Interior finishes.
More informationINTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS SECTION 801 GENERAL 801.1 Scope. The provisions of this chapter shall govern interior finish, interior trim, furniture, furnishings, decorative
More informationINTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS SECTION 801 GENERAL 801.1 Scope. The provisions of this chapter shall govern interior finish, interior trim, furniture, furnishings, decorative
More informationINTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS SECTION 801 GENERAL 801.1 Scope. The provisions of this chapter shall govern furniture and furnishings, interior finishes, interior trim,
More informationINTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS SECTION 801 GENERAL 801.1 Scope. The provisions of this chapter shall govern furniture and furnishings, interior finishes, interior trim,
More informationINTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS SECTION 801 GENERAL 801.1 Scope. The provisions of this chapter shall govern furniture and furnishings, interior finishes, interior trim,
More information"Public occupancy." Means all of the following:
ACTION: Final DATE: 12/04/2017 11:44 AM 1301:7-7-08 Interior finish, decorative materials and furnishings. (A) Section 801 General (1) 801.1 Scope. The provisions of this rule shall govern interior finish,
More informationFirst Revision No NFPA [ Section No ]
National Fire Protection Association Report of 13 http://submittals.nfpa.org/terraviewweb/contentfetcher?commentpara... 10/28/2015 10:35 AM First Revision No. 5501-NFPA 5000-2015 [ Section No. 3.3.220.4
More informationFirst Revision No NFPA [ Section No ]
National Fire Protection Association Report of 17 http://submittals.nfpa.org/terraviewweb/contentfetcher?commentpara... 10/21/2015 9:28 AM First Revision No. 4502-NFPA 101-2015 [ Section No. 3.3.92.4 ]
More informationReport on First Revision June 2014 NFPA 5000
5000 FR520 BLD-FUR (10.1 and 10.2) 10.1* General. 10.1.1 Application. Interior finish for buildings shall comply with this chapter. 10.1.2 Automatic Sprinkler Systems. Where another provision of this chapter
More informationResponsibilities: Effective Date: November Revision Date: January 27, VP, Facilities and Construction Management
Title: Fire Safety Requirements for Interior Finish Materials Procedure Effective Date: November 2005 Revision Date: January 27, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction
More informationCHAPTER 6 TYPES OF CONSTRUCTION
CHAPTER 6 TYPES OF CONSTRUCTION SECTION 61 GENERAL 61.1 Scope. The provisions of this chapter shall control the classification of buildings as to type of construction. SECTION 62 CONSTRUCTION CLASSIFICATION
More informationWhat is a Code? 2012 IFC and IBC Interior Finishes and Foam Plastics IBC and IFC Interior Finishes and Foam Plastics
2012 IBC and IFC Interior Finishes and Foam Plastics Based on the 2012 International Building Code (IBC ) and the 2012 International Fire Code (IFC ) International Building Code What is a Code? 1 2012
More informationPLASTIC CHAPTER 26. SECTION 2602 DEFINITIONS Definitions. The following terms are defined in Chapter
CHAPTER 26 PLASTIC SECTION 2601 GENERAL 2601.1 Scope. These provisions shall govern the materials, design, application, construction and installation of foam plastic, foam plastic insulation, plastic veneer,
More informationFIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
More informationCHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION
CHAPTER 26 PLASTIC SECTION BC 2601 GENERAL 2601.1 Scope. These provisions shall govern the materials, design, application, construction and installation of foam plastic, foam plastic insulation, plastic
More informationInterior FRT Wood. References of Previous Model Building Codes
Interior FRT Wood References of Previous Model Building Codes Table of Contents SBBCI Standard Building Code 1 ICBO Uniform Building Code 3 BOCA National Building Code 5 10-SBBCI STANDARD BUILDING CODE
More informationCHAPTER 26 PLASTIC SECTION 2601 SECTION 2603 GENERAL FOAM PLASTIC INSULATION
CHAPTER 26 PLASTIC SECTION 2601 GENERAL 2601.1 Scope. These provisions shall govern the materials, design, application, construction and installation of foam plastic, foam plastic insulation, plastic veneer,
More informationCode Review for Theaters and Props
Code Review for Theaters and Props I. INTRODUCTION Fire- and Life-Safety Group (FLS) This document was prepared to list the requirements for theaters and props. These requirements are based on the 2007
More informationWOOD USE IN NONCOMBUSTIBLE BUILDINGS
INTRODUCTION The National Building Code of Canada (NBCC) 1 requires that some buildings be of noncombustible construction under its prescriptive requirements. Its use in certain types of buildings such
More informationSECTION 702 DEFINITIONS
ACTION: Final DATE: 05/6/017 :17 PM 4101:1-7-01 Fire and smoke protection features. [Comment: When a reference is made within this rule to a federal statutory provision, an industry consensus standard,
More informationFIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
More informationVERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES
VERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES The following is the Study Group report that was considered by the CTC at its October 13-14, 2011 meeting.
More informationFIRE-RESISTANCE-RATED CONSTRUCTION
CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION SECTION BC 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials and assemblies used for structural fire resistance and fire-resistance-rated
More informationInterior FRT Wood. References to ICC Building Codes
Interior FRT Wood References to ICC Building Codes Table of Contents International Building Code (IBC) 1 International Residential Code (IRC) 6 International Mechanical Code (IMC) 7 INTERNATIONAL BUILDING
More informationCode Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings
Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council Copyright This presentation is protected
More informationCode Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council
Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings John Buddy Showalter, PE VP, Technology Transfer American Wood Council Copyright This presentation is protected by US and International
More informationUpdated references to SEI/ASCE 7 to the 2016 edition once it is available.
Committee Input No. 8008-NFPA 5000-2015 [ Global Input ] Updated references to SEI/ASCE 7 to the 2016 edition once it is available. Submitter Information Verification Submitter Full Name: Tracy Vecchiarelli
More informationFollowing contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.
Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD. Included are selected sections of codes taken directly from: 1997 Uniform
More informationCode Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings
Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council Copyright This presentation is protected
More informationFire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II
Fire Inspection and Code Enforcement, 7 th Edition Chapter 6 Building Construction: Components Today we will Discuss fire walls, party walls, fire partitions, and curtain walls Discuss roof types and coverings
More informationFS , 712, 713, 714
VERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL JUNE 28-29, 2012 PUBLIC COMMENTS CTC Code Change Proposal FS50-12 was Approved as Modified as shown below - No public comments for the Group
More informationFIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
More informationSignage Code. H101.2 Signs exempt from permits. The following signs are exempt from the requirements to obtain a permit before erection:
Signage Code ICC Code: Appendix H: Signs SECTION H101 GENERAL H101.1 General. A sign shall not be erected in a manner that would confuse or obstruct the view of or interfere with exit signs required by
More informationIBC GENERAL. Code Change No: G4-06/07. Original Proposal
DOCUMENTATION IBC GENERAL Code Change No: G4-06/07 Original Proposal Sections: 112.1, 1612.3, 3109.4.1.8, 3202.1.2, 3202.3.4, 3202.4, 3303.6, 3306.2 (IEBC [B] 1401.6.1), 3308.1(IEBC [B] 1403.1), 3409.9
More information&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &
&01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.
More informationReport to: Plumberex Specialty Products, Inc. Pipe Insulation and Fire Safety
GBH International 2 Friar's Lane, Mill Valley, CA, 94941 Telephone: (415) 388-8278 FAX: (415) 388-5546 e-mail: gbhint@aol.com Web site: www.gbhinternational.com Report to: Plumberex Specialty Products,
More informationNEWS LETTER MARCH 27, 2009
PLANNING, BUILDING & DEVELOPMENT SERVICES DEPARTMENT 580-1 Street S.E. Medicine Hat, Alberta T1A 8E6 Telephone: 529-8374 FAX 502-8038 1 NEWS LETTER MARCH 27, 2009 GENERAL As you are probably aware there
More informationEXIT ACCESS RAMP. An interior ramp that is not a required interior exit ramp.
Coordination with language throughout code 10/05/2011 Stair vs. stairway Repetitive language with stairways and ramps Including ramps when applicable The locations for stair, stairway and ramp as used
More informationM E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot Final Result s
M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings and Contents (BLD-FUR) Kristin Collette, Staff Liaison DATE: October 29, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Result
More information2012 Code Conforming Wood Design 15
2012 Code Conforming Wood Design 15 Mixed Occupancy Mixed occupancy buildings are permitted a total allowable building area calculated in accordance with Section 506.5. But, a single-story basement does
More informationWoodWorks. Learning Objective. Presentation Overview. Fire Protection II Requirements for rated assemblies and common detailing
WoodWorks Fire Protection II Requirements for rated assemblies and common detailing Scott Lockyear, PE Learning Objective Discuss the type of rated assembly requirements in the International Building Code.
More information2012 IBC Inspection of Fire-resistance Rated Walls
Accreditation 2012 IBC Inspection of Fire-resistance Rated Walls Based on the 2012 International Building Code (IBC ) The International Code Council has been accredited as an Authorized Provider by the
More informationInternational Building Code Essentials for Wood Construction
International Building Code Essentials for Wood Construction Dennis Richardson, P.E., C.B.O., CASp Western Regional Manager American Wood Council The Wood Products Council is a Registered Provider with
More informationAEROSOLS CHAPTER , ,600 13, ,000 3 TABLE CLASSIFICATION OF AEROSOL PRODUCTS
CHAPTER 28 AEROSOLS SECTION 2801 GENERAL 2801.1 Scope. The provisions of this chapter, the International Building Code and, where specifically indicated, NFPA 30B shall apply to the manufacturing, storage
More informationCombustible Exterior Wall Cladding Systems: An ICC Perspective
Combustible Exterior Wall Cladding Systems: An ICC Perspective The tragic Grenfell Tower fire in London brought extensive public focus on combustible exterior wall systems, often called cladding, prompting
More information1. Frozen food warehouses used solely for storage of Class I and II commodities where protected by an approved automatic sprinkler system.
Draft curtains are typically used in warehouses, aircraft hangars and large industrial plants to contain or channel smoke that rises to the ceiling in a fire. They can keep the smoke from rolling across
More informationComparison of the life safety elements of the 1997 UBC and the IBC 2000.
Comparison of the life safety elements of the 1997 UBC and the IBC 2000. Introduction The Building Performance Research Institute s mission is primarily one of education on building safety and performance.
More informationAEROSOLS CHAPTER 28. Level 3 aerosol products. Those with a total chemical heat
CHAPTER 28 AEROSOLS SECTION 2801 GENERAL 2801.1 Scope. The provisions of this chapter, the construction code in effect at the time of construction and NFPA 30B shall apply to the manufacturing, storage
More informationFCIA Webinar Gypsum Wall Patching
FCIA Webinar Gypsum Wall Patching Firestop Contractors International Association Hillside, IL +1-708-202-1108 - office Bill McHugh bill @ fcia.org Nestor Sanchez, USG Corp. nsanchez@usg.com DIIM Firestopping
More informationFirst Revision No NFPA [ Section No ]
First Revision No. 1001-NFPA 5000-2015 [ Section No. 7.2.5.6.8 ] Global FR-6108 7.2.5.6.8 Exterior Nonbearing Walls. Exterior nonbearing walls tested shall be permitted when tested in accordance with,
More informationPROPOSAL BALLOT DUE BY: Wednesday, September 2, 2009
PROPOSL BLLOT DUE BY: Wednesday, September 2, 2009 NFP 265 FIZ- Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls Staff Liaison:
More information2015 IBC Exit Systems
Objectives 2015 IBC Exit Systems Based on the 2015 International Building Code Upon completion, participants will be better able to: Determine those means of egress components that are defined as exits
More informationCALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%
CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE EXAM ID: I6 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 3 % 0101. Project Administration 3% Verify that plans,
More informationChapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION
Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION Sections: 4-16-01 PURPOSE 4-16-02 APPLICABLE AREA 4-16-03 CONSTRUCTION AND OCCUPANCY 4-16-04 UPPER BUILDING AREA, HEIGHT, NUMBER OF STORIES
More information(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS
Florida Specific Amendment Code Reference NFPA 101 Open Parking Structure. A parking structure that, at each parking level, has wall openings open to the atmosphere, for an area of not less than 1.4 ft2
More information2006 International Residential Code Errata (Portions of text and tables not shown are unaffected by the errata)
1st through 6th PRINTING (Posted 07-25-2011) INDEX JOINTS, PIPE Slip.P3003.3.7 P2704.1 2009 International Residential Code Errata Page 1 of 1 FIRST PRINTING (Updated September 12, 2006) CHAPTER 1 ADMINISTRATION
More information9/19/2018. Session: 2018 IEBC Essentials - History
9/19/2018 Session: 2018 IEBC Essentials - History 1 2018 IEBC Essentials Part 1 Based on the International Existing Building Code (IEBC ) Introductions Instructor Provided assistance to: New Jersey HUD
More informationSUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:
IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:
More informationINTERNATIONAL CODE INTERPRETATIONS
2012 INTERNATIONAL CODE INTERPRETATIONS PREFACE The 2012 International Codes promulgated by the International Code Council (ICC ) comprise a comprehensive set of model regulations for the construction
More informationBuilding Codes and Ordinances ARC 227
Building Codes and Ordinances ARC 227 Week 6 Fire Resistive Construction 03.02.10 Instructor: Rick Staub, AIA Email: staub@pointonearchitects.com Phone: 860-434-7707 Fire Resistive Construction Passive
More informationReport of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and
BCAC MOE Work Group Summary with Files Revised 11-20-2017 with meeting notes Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting ITEM Topic SECTION Notes
More informationButte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)
2016 CBC Chapter 7A and CRC Section R337 (The use of paints, coatings, stains, or other surface treatments are not an approved method of protection as required in this chapter.) The Wildland Urban Interface
More informationE2-09/ (IFC [B] )
Code Technology Committee 2010 Final Action Agenda The following are code changes and public comments to be considered at the 2010 Dallas Final Action Hearings that are related to the CTC Area of Study
More informationA Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation
A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation Agenda Why Do Codes Require Thermal or Ignition Barriers? What is a Thermal Barrier? Where is it required? What is an Ignition
More information1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights
1 Exam Prep Application and Finishing of Gypsum Board GA-216-2013 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2013 Application and Finishing of Gypsum Panel Products. Each
More informationE?? , , , , , , , , , , , , Table ,
CTC to BCAC Unenclosed Exits 2015 Group A Code Change Cycle Copyright 2014 International Code Council, Inc. IBC 10-31 E?? 15 202, 1005.3.2, 1009.3, 1009.4, 1019.3, 1029.6, 1029.6.3, 1029.7, 1029.8, 1029.8.1,
More informationThe Lexington Division of Fire and Emergency Services. Fire Chief Robert G. Hendricks
The Lexington Division of Fire and Emergency Services Fire Chief Robert G. Hendricks The Code of Hammurabi 229. If a builder builds a house for someone, and does not construct it properly, and the house
More informationSECTION R327.3 STANDARDS OF QUALITY
California Residential Code Section R327 Conformance Checklist Per CRC R327.1.4 The local building official shall, prior to construction, provide the owner or applicant a certification that the building
More informationExcerpts from the Uniform Building Code. (UBC) For The US
Excerpts from the Uniform Building Code (UBC) For The US Index 4301 FIRE-RESISTIVE STANDARDS 1. Section 4301(a) Standards of Quality 2. Section 4301(b) Definitions 4304 WALLS AND PARTITIONS 1. Sec.4304(a)
More information2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs
Class Outline Inspection of Fire-resistance-Rated Floors, Ceilings and Roofs Based on 2012 International Building Code (IBC) Introduction Determining fire resistance Test standards Definitions Alternate
More information1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights
1 Exam Prep Application and Finishing of Gypsum Board GA-216-2016 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2016 Application and Finishing of Gypsum Panel Products. Each
More informationRLGA. Gypsum Board Construction 2012 International Building Code. By Ronald L. Geren, AIA, CSI, CCS, CCCA, SCIP
Gypsum Board Construction 2012 International Building Code By Ronald L. Geren, AIA, CSI, CCS, CCCA, SCIP Gypsum board has been an important part of the construction industry for more than 100 years. Its
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION GYPSUM BOARD ASSEMBLIES
SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.
More information2018 IBC Chapter 6 Types of Construction
Study Session 3 2018 IBC Chapter 6 Types of Construction OBJECTIVE: REFERENCE: KEY POINTS: To gain an understanding of how a building is classified as a specific type of construction, based on the construction
More information2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs
Accreditation 2012 IBC Inspection of Fire-resistance-Rated Floors, Ceilings and Roofs Based on 2012 International Building Code The International Code Council has been accredited as an Authorized Provider
More informationAdvanced Studies of the International Building Code. Presented by Steve Thomas, Colorado Code Consulting, LLC
Advanced Studies of the International Building Code Presented by Steve Thomas, Colorado Code Consulting, LLC Advanced Studies of the International Building Code Instructor Steve Thomas, CBO President,
More informationCODE ANALYSIS REPORT SECOND FLOOR
CODE ANALYSIS REPORT SECOND FLOOR 384 DWIGHT STREET HOLYOKE, MA Prepared by Dietz & Company Architects, Inc. 17 Hampden Street Springfield, MA March 2014 INTRODUCTION The following report is a preliminary
More information2009 IBC Section 1024 Approved Luminous Egress Path Markings
2009 IBC Section 1024 Approved Luminous Egress Path Markings Where Required Buildings of Groups A (Assembly), B (Business), E (Education), I (Institutional), M (Mercantile) and R-1 (Residential transient
More informationCTC MEETING #25 CHILD WINDOW SAFETY REPORT
CTC MEETING #25 CHILD WINDOW SAFETY REPORT The Child Window Safety SG has not met following the 2012 Final Action Hearing. Group B activities did not necessitate SG meetings as the activity will be limited
More informationOverview of Revised School Regulation
Office of the State Fire Marshal Overview of Revised School Regulation By: Timothee Rodrique Director, OSFM October, 2003 Training Effective Fire Prevention through Public Education Introduction! Purpose
More informationException: All layers of single and multilayer reflective plastic core foil insulation shall comply with Section 2604.
1. Fiberboard insulation shall comply with Chapter 23. 2. Foam plastic insulation shall comply with Chapter 26. 3. Duct and pipe insulation and duct and pipe coverings and linings in plenums shall comply
More informationINTERIOR ENVIRONMENT
CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,
More informationORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.
ORDINANCE NO. 7222 AN ORDINANCE AMENDING CHAPTER 8 OF THE CODE OF ORDINANCES, REGULATING BUILDINGS WITHIN THE CORPORATE LIMITS OF THE CITY OF MANHATTAN, KANSAS; INCORPORATING BY REFERENCE THE INTERNATIONAL
More information2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)
TWELFTH PRINTING (Updated December 6, 2016) Note for 706.5.1: This is an erratum in the 8 th, 9 th, 10 th and 11 th printing only. The reference is correct in other editions. 706.5.1 Exterior walls. Where
More informationBuilding/Structural Summary
2004 Florida Building Code, Building Building/Structural Summary 50-minutes (1 CEH) 0701155259 Florida Department of Community Affairs Mo Madani CBO, Technical Manager Florida Building Commission Web:
More informationA. This Section includes acoustical panel ceilings installed with exposed suspension systems.
SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More information2. Maximum useable storage height for each storage area. Height to be measured from finished floor to the highest point of the commodity
High-Piled storage plans are required for all high-pile storage buildings or arrangements within buildings when storage meets or exceeds 501 square feet of Class 1 through IV commodities and any quantity
More informationNFPA Committee on Fire Tests
NFPA Committee on Fire Tests M E M O R A N D U M TO: FROM: NFPA Technical Committee on Fire Tests Linda MacKay DATE: September 21, 2009 SUBJECT: NFPA 251, 253, 262, 265, 285, 286 ROP Letter Ballot Final
More informationC. Wallboard shall not be glued directly to masonry or concrete walls below grade: provide furring.
09 0561 COMMON WORK RESULTS FOR FLOORING PREPARATION 09 0562 REMEDIAL FLOOR COATING 09 2116 - GYPSUM BOARD ASSEMBLIES A. Special consideration shall be given to the noise reduction characteristic and installation
More informationOutcomes of ICC Tall Wood Ad Hoc Committee: Proposals and Discussion
Outcomes of ICC Tall Wood Ad Hoc Committee: Proposals and Discussion DES605 Sam Francis, C.B.O. Senior Director, National Programs American Wood Council Paul Coats, P.E., C.B.O. Southeast Regional Manager
More information2015 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs
Class Outline Inspection of Fire-Resistance-Rated Floors, Ceilings and Roofs Based on 2015 International Building Code, (IBC ) Introduction Determining fire resistance Test standards Definitions Alternate
More information2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)
ELEVENTH PRINTING (Updated January 10, 2017) 406.4 Public parking garages. Parking garages other than private parking garages, shall be classified as public parking garages and shall comply with the provisions
More informationSECTION ACCORDION FOLDING PARTITIONS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 22 26.13 ACCORDION FOLDING PARTITIONS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationAdvanced FBC: Significant Changes to the 5 th Edition (2014) Florida Building Code, Building and Residential. presented by
Advanced FBC: Significant Changes to the 5 th Edition (2014) Florida Building Code, Building and Residential presented by T. Eric Stafford T. Eric Stafford & Associates, LLC This material is protected
More information2006 to 2012 IBC. Significant Changes
2006 to 2012 IBC Significant Changes 1. Addition 303.3 Assembly Group A 2. Assembly uses intended for food and/or drink consumption including, but not limited to: Banquet halls Casinos (gaming areas) added
More information