1 Installation recommendations Washer-extractor PW 6080 EL AV/LP en - GB Mat. no / 01
2 It is essential to read the operating and installation instructions before installing, commissioning or using the machine. This avoids the risk of accidents or damage. All rights reserved Mat. no / 01 2
3
4
5
6
7
8 Technical Datasheet Washer-extractor: Heating: PW 6080 AV/LP Electric (EL) Legend: Circled, bold-type abbreviations: Connection required Abbreviations surrounded by broken circle: Connection optional or required, depending on model Optional extras: UM BS Miele plinth Concrete plinth UO 6008 (UO = Open plinth) Height mm 305 Width mm 680 Depth mm 679 UG 6008 (UG = Closed plinth) Height mm 305 Width mm 692 Depth mm 685 US 6008 (US = Plinth with drawer) Height mm 320 Width mm 692 Depth mm 685 Concrete plinth (min. quality C12/15) Recommended height mm 300 Minimum height mm 70 Recommended width mm 700 Recommended depth mm 700 It must be ensured that the om-site concrete plinth is anchored to the floor! Machine connections: Electrical connection 1. Standard voltage (as supplied) V 3N AC 400 Frequency Hz 50 Rated load kw 8.2 Fuse rating A 3 16 Connection cable cross-sectional area mm² Connection cable length mm 2000 Connection cable without plug (supplied as standard) Country variations: 1. Standard voltage (as supplied) V 1N AC Frequency Hz 50 Rated load kw Fuse rating A 1 25 Connection cable cross-sectional area mm² Connection cable length mm 2000 Connection cable without plug (supplied as standard) 1. Standard voltage (as supplied) V 3 AC 230 Frequency Hz 50 Rated load kw 8.2 Fuse rating A 3 20 Connection cable cross-sectional area mm² Connection cable length mm 2000 Connection cable without plug (supplied as standard) Technisches Datenblatt / Technical datasheet: PW 6080 EL AV/LP Datum / Date: Seite / Page: 8
9 Non-standard voltages: OS Standard voltage (as supplied) V 3 AC 440 Frequency Hz 60 Rated load kw 7.9 Fuse rating A 3 16 Connection cable cross-sectional area mm² Connection cable length mm 2000 Connection cable without plug (supplied as standard) Electrical connection must be in accordance with local and national regulations. Plug and socket connection in accordance with IEC/EN and IEC/EN recommended to facilitate electrical safety tests. If the machine is connected via a fixed connection, a multipole switch must be provided on site to ensure complete isolation. Switches with a contact opening of more than 3 mm should be used. Such switches are, e.g., LS switches, fuses and contactors (IEC/EN 60947). A wall socket or mains isolator must be visible and accessible after installation. A new connection, modification of an existing installation or earth checking, including the determination of suitable fuse rating, may only be carried out by a suitably qualified electrician in accordance with all local and national regulations. Cold water (soft water) Hot water (soft water) Alternative water supply (Optional) Min. flow pressure kpa 100 Max. pressure kpa 1000 Max. throughput l/min 11 On-site connection thread according to DIN Inch ¾" external thread Length of connection hose mm 1550 (parts supplied: 1 connection hose) Water requirements (average for 60 C programme) With standard connection (with hot water) l/h Approx. 70 If hot water supply is not available, a sufficient supply of cold water must be ensured. If connected to an alternative water supply (optional), subtract cold water volume. Max. temperature C 70 Min. flow pressure kpa 100 Max. pressure kpa 1000 Max. throughput l/min 11 On-site connection thread according to DIN Inch ¾" external thread Length of connection hose mm 1550 (parts supplied: 1 connection hose) Water requirements (average for 60 C programme) l/h Approx. 70 It is possible to connect the machine to a very hot water supply with temperature from 70 C to max. 85 C. For this a special connection hose is required. This special hose is available from the Miele Spares Dept. In addition, the Miele Service Dept. or an authorised dealer must reprogram the machine accordingly. If a hot water supply is not available, connect the hot water hose to a cold water supply! Min. flow pressure kpa 100 Max. pressure kpa 1000 Max. throughput l/min 11 On-site connection thread according to DIN Inch ¾" external thread Length of connection hose mm 1550 (parts supplied: 1 connection hose) Water requirements (average for 60 C programme) l/h Not yet available Technisches Datenblatt / Technical datasheet: PW 6080 EL AV/LP Datum / Date: Seite / Page: 9
10 Waste water Model with dump valve Drainage via drain pump Fittings (supplied) Max. temperature C 70 Machine waste water connection (external diameter) mm 75 [DN 70] On-site drain (internal diameter) mm 75 [sleeve DN 70] Max. transient throughput l/min 62 Vented drainage required. If ventilation is insufficient, fit Miele kit, Mat. no Drain manifolds serving several machines must be of sufficient cross-section. Max. temperature C 70 Drain hose (inner diameter) mm 22 [DN 22] On-site hose sleeve for drain hose mm (inner diameter x length) Max. transient throughput l/min 26 Max. head height (measured from base of unit) mm 1000 Vented drainage required. If ventilation is insufficient, fit Miele kit, Mat. no Drain manifolds serving several machines must be of sufficient cross-section. Miele plinth UG/UO fasteners (to secure machine to plinth) 4 screws DIN 571 (Ø length) mm rawl plugs (Ø length) mm Machine must be bolted to the floor! Fixing materials for floating screed floor to be provided on site Miele plinth US fasteners (to secure machine to plinth) 4 screws DIN 571 (Ø length) mm rawl plugs (Ø length) mm 8 40 Machine must be bolted to the floor! Fixing materials for floating screed floor to be provided on site On concrete plinth 2 metal brackets 2 screws DIN 571 (Ø length) mm rawl plugs (Ø length) mm 8 40 Machine must be bolted to the floor! Fixing materials for floating screed floor to be provided on site Machine data Machine width mm 700 Machine depth mm 727 Machine height mm 1020 Casing width mm 692 Casing depth mm 690 Min. access width to installation site mm 720 Minimum rear wall gap (measured to front of machine) mm 1100 Minimum wall gap (to front edge of machine) mm 900 With an installation with the minimum gap, additional work may be required when service or repair work is necessary. Net weight kg 140 Dynamic floor load, max. N 2600 Static floor load, max. N 1850 Dynamic load, max. N 750 Drum frequency, max. Hz 22 Average heat dissipation W Not yet available (dependent on ambient room temperature and programme selected) Sound pressure level (re 20 mpa), (measured at a distance of 1 m from the machine and at a height of 1.6 m) Installation should only be carried out by authorised fitters in accordance with valid regulations! Observe installation instructions when installing machine! All rights reserved! Dimensions in mm db (A) <70 Technisches Datenblatt / Technical datasheet: PW 6080 EL AV/LP Datum / Date: Seite / Page: 10
Installation Plan. Washer-extractor PW 6088 EL LP. en - AU M.-Nr
Installation Plan Washer-extractor PW 6088 EL LP en - AU 14.14 M.-Nr. 09 923 540 Australia: Miele Australia Pty. Ltd. 1 Gilbert Park Drive KNOXFIELD Victoria 3180 Tel. +61 3 97647-100 Fax +61 3 97647-129
More informationInstallation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01
Installation plan Washer-extractor PW 6107 EL en - GB 10.11 M.-Nr. 09 270 450 / 01 M.-Nr. 09 270 450 / 01 2 Technical Datasheet Washer-extractor: Heating: PW 6107 Electric (EL) Legend: Solid circle
More informationInstallation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02
Installation plan Tumble dryer PT 8807 EL (Electrically heated) 38.15 en - US Mat. NR. 09 883 210 / 02 U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: Fax: 800-991-9380
More informationStack Parking Surface Mounted Stackers
1 / 6 Stack Parking Surface Mounted Stackers swiss-park V-2 Comfort The V-2 is designed to park cars of any size thanks to its vertical adjustability. It will accommodate cars as tall as the garage ceiling
More informationTender specification KLAUS Multiparking MultiBase U1 EB / MultiBase U1 DB
Preliminary technical remarks 1. Basis for the design are 1.1 the garage regulations (GaVo) according to the building regulations in the latest version, 1.2 the EC Machinery Directive 2006/42/EC, Appendix
More informationAQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH
AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH SYSTEM FOR THE EXPLOITATION OF RAINWATER AQUAPROF TOP ACTIVE SWITCH AQUAPROF BASIC / AQUAPROF TOP AQUAPROF TOP Applications The AQUAPROF unit is used for the management
More informationTender specification KLAUS Multiparking MultiBase 2072 outdoor installation EB MultiBase 2072 outdoor installation DB
Preliminary technical remarks 1. Basis for the design are 1.1 the garage regulations (GaVo) according to the building regulations in the latest version, 1.2 the EC Machinery Directive 2006/42/EC, Appendix
More informationThree-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier
of 5 Page Car SingleVario 06 Stack Parker 06 50 for vehicle up to 5.00 m = 6 long (50 for vehicle up to 5.0 m 7 long) Depending on location, design also as wind protection. Product Data CONFORMITY 06/06/G63
More informationSeries description Wilo-Drain STS 40
Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Subject to change 09/2008 WILO SE Wilo Catalogue C2 - - Sewage pumps from DN 32 to DN 800 Materials Pump housing: EN-GJL-250 Pedestal:
More informationBarrier. Delimitation. Water drainage
Car Cutting through Grounding 0 for vehicle up to.00 m = 1 long (0 for vehicle up to.0 m 1 long) KLAUS Multiparking GmbH Hermann-Krum-Straße D-1 Aitrach Fon + (0 ) 0-0 Fax + (0 ) 0- info@multiparking.com
More informationPRODUCT DATA kg / 2600 kg
Car KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-19 Aitrach Fon +49 (0 ) 6 0-0 Fax +49 (0 ) 6 0- info@multiparking.com www.multiparking.com PRODUCT DATA 2000 kg / 2600 kg 1 2 All space requirements
More informationGuide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523
Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type-No.: Type 523 Table of contents on Page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use
More informationGelovit 200 en English
Gelovit 200 en English Translation of the original instructions BA 85 981 / 02 334.00001... en Gelovit 200 This unit documentation is part of the unit and must be enclosed when selling or passing on the
More informationINDeX Rack Installation Notes
INDeX Rack Installation Notes 38PJC00001SBA - Issue 8 (09/01/2002) Page 2 Contents Contents Rack Mounted Installation...3 Introduction... 3 Rack Installation Requirements... 3 Summary Details... 3 The
More informationKBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions
Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect
More informationBarrier. Delimitation. Water drainage
KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-88319 Aitrach Fon +49 (0 ) 75 65 5 08-0 Fax +49 (0 ) 75 65 5 08-88 info@multiparking.com www.multiparking.com PRODUCT DATA Outdoor Cutting through Grounding
More informationPRODUCT DATA kg
KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-88319 Aitrach Fon +9 (0 ) 75 65 5 08-0 Fax +9 (0 ) 75 65 5 08-88 info@multiparking.com www.multiparking.com PRODUCT DATA 00 kg Page 1 Car Garage (basement
More informationIce and snow melting Pavements, roads and ramps
Installation Guide Ice and snow melting Pavements, roads and ramps electricheating.danfoss.com Table of Contents 1 Introduction.................... 3 1.1 Safety Instructions...............3 1.2 Installation
More informationInstruction manual AS 300 CG. Waste water filtration unit. Im Geer 20, D Isselburg. Descriptioin / Type-No.: AS 300 CG Typ 539
Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Descriptioin / Type-No.: Typ 539 Table of contents on page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use
More informationInstallation Guide. Ice and snow melting. Pavements, roads and ramps. Intelligent solutions with lasting effect. Visit DEVI.com
Installation Guide Ice and snow melting Pavements, roads and ramps Intelligent solutions with lasting effect Visit DEVI.com Table of Contents 1 Introduction.................... 3 1.1 Safety Instructions...............3
More informationUltraGas. Technical Data Output range 15 to 2000 kw. Condensing Gas Boiler /02-07/15 Subject to modifications
UltraGas Condensing Gas Boiler Technical Data Output range 15 to 2000 kw - 07/15 Subject to modifications UltraGas UltraGas Condensiing 15-2000D Gas Boiler Contents page Description 3 UltraGas 15-100 Technical
More informationInstallation instruction Maintenance Bypass option
CONTENTS General... 3 1 Installation... 3 1.1 Environment... 3 1.2 s... 3 1.2.3 Installation of BP-6000... 4 1.3 Starting UPS... 4 1.4 Using the Maintenance Bypass... 6 General This manual completes the
More informationFAST/SPS-Sinter Press DSP 520 FAST/SPS BY DR. FRITSCH FAST PRECISE ECONOMICAL. USA Distributor.
FAST/SPS-Sinter Press DSP 520 FAST/SPS BY DR. FRITSCH FAST PRECISE ECONOMICAL www.msesupplies.com USA Distributor Technical specification DSP 520 FAST/SPS sintering is a technology with many advantages
More informationFAST/SPS-Sinter Press DSP 535 FAST/SPS BY DR. FRITSCH FAST PRECISE ECONOMICAL. USA Distributor.
FAST/SPS-Sinter Press DSP 535 FAST/SPS BY DR. FRITSCH FAST PRECISE ECONOMICAL www.msesupplies.com USA Distributor Technical specification DSP 535 FAST/SPS sintering is a technology with many advantages
More informationWater Softener softliq:mc. Intended use. Function. Design
Subject to modifications TD2-BS000de_004 Edition May 2016 Intended use The water softener softliq:mc may only and exclusively be used for the softening and partial softening of cold drinking water. The
More informationENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER:
ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER: . INTRODUCTION This manual contains information that will allow to take
More informationIndustrial flue gas probes. Instruction manual
Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...
More informationSubmersible Borehole Pump. Ixo N. Type Series Booklet
Submersible Borehole Pump Ixo N Type Series Booklet Legal information/copyright Type Series Booklet Ixo N All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationPRODUCT DATA kg / 2600 kg
Car KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-88319 Aitrach Fon +49 (0 ) 65 5 08-0 Fax +49 (0 ) 65 5 08-88 info@multiparking.com www.multiparking.com PRODUCT DATA 2000 kg / 2600 kg 1 2 11 Shaft for
More informationWater drainage 11 G82-165/295 G82-165/310 G82-185/310. car height car height height. car height upper (L) G82-185/325 G82-195/315 G82-195/335
KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-883 Aitrach Fon +4 (0 ) 75 5 5 08-0 Fax +4 (0 ) 75 5 5 08-88 info@multiparking.com www.multiparking.com PRODUCT DATA 00 kg Page Car Page Garage (basement
More informationPRODUCT DATA kg / 2600 kg
Car Garage (basement garage) 100 Cutting through 6 0 Free space KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-88319 Aitrach Fon +49 (0 ) 7 6 08-0 Fax +49 (0 ) 7 6 08-88 info@multiparking.com www.multiparking.com
More informationEnvironmental simulation chamber for cyclical temperature
MK series (E2.1) Environmental simulation chambers Environmental simulation chamber for cyclical temperature The BINDER environmental simulation chamber of the MK series is suitable for heat or cold testing
More informationPHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW
TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0
More informationEquipment Information
QCM Equipment Information INDEX: DESCRIPTION AND KEY FEATURES LAYOUT NOMINAL TECHNICAL DATA CONFIGURATION Sealed Air Ltd. Clifton House, 1 Marston Road St. Neots GB-Cambridgeshire PE19 2HN United Kingdom
More informationMagneticTurbo TM. TurboDrag pumps with pumping speed up to 400 l/s TMH/U 200 M / TMH/U 400 M. Pumping speed. Start / Chapter content 10-6
TurboDrag pumps with pumping speed up to 400 l/s TMH/U 200 M / TMH/U 400 M Magnetic bearing system with 3 active and 2 passive axes, with the following benefits: maintenancefree, free of hydrocarbons,
More informationData Sheet Wöhr Combilift 552-2,0
Data Sheet Wöhr Combilift 552-2,0 Special solution for driving through to reach a rear parking Suitable for condominium and office buildings. For permanent user only! 15 35 40 30 50 In case of short time
More informationUnloading Valve Series R4U
Characteristics Series RU Subplate mounted unloading valves series RU are used to unload a circuit at low pressure. The mechanically adjustable pressure signal to unload the main stage has to be applied
More informationData Sheet WÖHR COMBILIFT 552-2,6
COMILIFT 552-2,6 04.2018 C027-5274 WÖHR Autoparksysteme GmbH 01 Data Sheet WÖHR COMILIFT 552-2,6 Special solution for driving through to reach a rear parking Suitable for condominium and office buildings.
More informationINSTALLATION MANUAL MULTI DECK HOT MERCHANDISERS MD Versions. Solid back 3 level Pass through 3 level
INSTALLATION MANUAL MULTI DECK HOT MERCHANDISERS MD 60-100 - 120 Versions Solid back 3 level Pass through 3 level MD 60-3 solid back MD 100-3 pass through - NOTICE - This manual is prepared for the use
More informationRB1000CR ASTM 3M WIDE ROADBLOCKER FOUNDATION LAYOUT
300 FIRST POUR 240 240 1570 O/A FOUNDATION HEIGHT 930 930 1270 SECOND POUR TO F.F.L. 60 TO F.F.L. 10 PROUD, PERIMETER BASE, F.F.L. 1000 RAISE HEIGHT 185 2800 CONCRETE FOUNDATION O/A 932 932 185 4100 CONCRETE
More informationPre-installation Manual. Plate Processor 68/85 Thermal
Pre-installation Manual Plate Processor 68/85 Thermal Pre-installation Manual Plate Processor 68/85 Thermal T1965 Edition DC, October 2011 Part No 51280 68/85 PLATE PROCESSOR INTRODUCTION RESERVATIONS
More informationA class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.
A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM www.jumag.de OIL OR GAS FIRED STEAM BOILER A class of its own Steam within
More informationKLAUS Multiparking GmbH Hermann-Krum-Straße 2 D Aitrach Fon+49 (0) Fax +49 (0)
KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-88319 Aitrach Fon+49 (0) 7565508-0 Fax +49 (0) 7565508-88 info@multiparking.com www.multiparking.com PRODUCT DATA 2000 kg / 0 kg Garage (basement garage)
More informationTGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series
Absorption Chillers TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Stable Chilled Water Outlet Temperature PID control is applied to maintain constant chilled water outlet temperature. When the cooling
More informationOperate Manual. DA-1600i Stud Welding Machine. DA-2000i Stud Welding Machine. DA-2500i Stud Welding Machine
DA-1600i Stud Welding Machine DA-2000i Stud Welding Machine DA-2500i Stud Welding Machine Operate Manual KENT STUD WELDING CO., LTD 1 Content 1. Preface------------------------------------------------------------------------------
More informationENGLISH Datasheet JIS Miniature Thermocouple Connector Panel Fascia Sockets Types K, J, T, E, R/S & B (JIS Colour Code)
ENGLISH Datasheet JIS Miniature Thermocouple Connector Panel Fascia Sockets Types K, J, T, E, R/S & B (JIS Colour Code) Miniature thermocouple fascia mounting sockets with clip All fascia mounting sockets
More informationSERVO-HYDRAULIC UNIVERSAL TESTING MACHINE SERIES A
SERVO-HYDRAULIC UNIVERSAL TESTING MACHINE SERIES A RoboTest Series A Servo-Hydraulic Universal Testing Machine feature servo-valve control of hydraulic power to perform accurate and reliable tension and
More informationData Sheet Wöhr Combilift 552-2,6
Data Sheet Wöhr Combilift 552-2,6 Special solution for driving through to reach a rear parking Suitable for condominium and office buildings. For permanent user only! In case of short time user (e.g. for
More informationHELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION
HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION INSTALLATION INSTRUCTIONS ENERGY AND SANITARY SYSTEMS Installation requirements General requirements The free-standing installation set is to be used for
More informationXN24 for Package Production. Site Preparation Guide XN24
Site Preparation Guide 10-2014 XN24 Contents 1. Preface... 4 2. Change record...5 3. Introduction...6 3.1 Welcome...6 3.2 About Installation...6 4. Responsibilities... 4.1 Esko Responsibilities... 4.2
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304
CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300
More informationMS SE 30AH 500 Equipment options
MS SE 0AH 500 Equipment options Equipment options with Schuko and CEE Order-No.: MS SE 0AH 500-Bsp-001 2 Distribution units (10 partitions) 4Schuko-Outlets 1 6/0,0A, 4-pol. 4MCB, B, 1-pol. Order-No.: MS
More informationIon exchange Unit IXU 1/4 Series
Ion exchange Unit IXU 1/4 Series Description The IXU series of easy-maintenance ion exchange units is designed to condition fire-resistant hydraulic and lubrication fluids based on phosphate esters (HFD-R)
More informationTechnical Data and Installation Instructions for use by heating contractor
Technical Data and Installation Instructions for use by heating contractor Low-loss headers Steel chamber with supply and return connections for both boiler and system loop For Residential and Commercial
More informationPRECAST RECTANGULAR CHAMBERS
STANDARD MODELS GENERAL ROUGH SKETCH Available for: Sewer manhole, valve chamber, trouser manhole, and pumping station. Ø60-Ø762 ADJUSTMENT RING 7-00-2-0 20-2 30-60 RING 200-30 60-60 000-220 9ø 6 FLAT
More informationCardok Carlift Data Sheet
CARDOK CARLIFT with Hydraulic scissors Installation to replace an access ramp Fast, Silent, Discreet, Design, High-Tech Dimensions: (Built to measure, all dimensions can be changed and adapted upon request
More informationENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code)
ENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code) Range of miniature thermocouple connectors with flat pins to suit thermocouple type Ideal
More informationCardok Carlift with Rigid Chains Data Sheet
Credit: SERAPID/LinkLift system CARDOK CARLIFT with Rigid chains technology Very fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp Dimensions:
More informationQUADROPARKER SERIES QUADROPARKER N4904 THE IDEAL SOLUTION FOR THE EXTERIORS; ON 4 LEVELS CAR STACKERS
QUADROPARKER SERIES CAR STACKERS QUADROPARKER N4904 THE IDEAL SOLUTION FOR THE EXTERIORS; ON 4 LEVELS SHORT DESCRIPTION INDEPENDENT PARKING SYSTEM ON 4 LEVELS LOWER LEVELS: SYSTEM COLUMNS ON THE CORNERS
More informationACO H a u s t e c h n i k
Alarm ACO H a u s t e c h n i k I n s t a l l a t i o n a n d o p e r a t i n g i n s t r u c t i o n s -02 Version 03.2010 Wastewater lifting system according to DIN 12050-1 for the collection and automatic
More informationContents. Company description. Company description 1 Product description 2 Reinforcement rebar Couplers 3
C A T A L O G U E Contents Company description 1 Product description 2 Reinforcement rebar Couplers 3 Features 4 Bartek Systems Coupler Dimensions 4 BARTEK SYSTEMS P Parallel rib peeling direct rolling
More informationENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)
ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code) Versatile, high quality, circuit board mounting miniature socket Specially designed
More informationINSTRUCTION MANUAL Worktop lift Slimlift 6230
English Worktop lift Slimlift 6230 Doc. No: M6230 Edition: 4 Date: 2012-12-10 INSTRUCTION MANUAL Worktop lift Slimlift 6230 Granberg Interior AB Box 6112 SE-600 06 Norrköping SWEDEN More information: www.granberg.se
More informationComputer Room Floor Grille
PI/9/1/B/2 Computer Room Floor Grille AFG TROX UK Ltd Telephone +44(0) 1842 754545 Caxton Way Telefax +44(0) 1842 763051 Thetford e-mail trox@troxuk.co.uk Norfolk IP24 3SQ www.trox.co.uk Contents Application
More informationSECTION VEHICLE LIFTS. B. Section Basic Electrical Materials and Methods: Power and controls wiring.
SECTION 14450 VEHICLE LIFTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Skylifts. 1.2 RELATED SECTIONS A. Section 03300 - Concrete: Footings and foundations. B. Section 16050 - Basic Electrical Materials and
More informationProtective Capony RTC-16
Protective Capony RTC-16 ASSEMBLY AND OPERATION MANUAL Protective Canopy RTC-16 Assembly and Operation Manual CONTENT: 1 APPLICATION...3 2 OPERATION CONDITIONS...3 3 TECHNICAL SPECIFICATIONS...3 4 DELIVERY
More informationINSTALLATION MANUAL COLD DELI 3/4/5 MERCHANDISERS
INSTALLATION MANUAL COLD DELI 3/4/5 MERCHANDISERS VERSIONS Self service Full service CD 3 self service on pedestal underframe - NOTICE - This manual is prepared for the use of trained Service Technicians
More informationTechnische Grundlagen
Technische Grundlagen 47 Technical bases Technical bases for point drainage ACO bath drains are used in areas where there is a demand for functional long-life solutions with high flow volumes combined
More informationPackaged Pump Stations
DELTA MEMBRANE SYSTEMS LTD packagedpumpsolutions Uniclass: L7316 CI/SfB: (52.9) X Packaged Pump Stations Delta Membrane Systems Limited delta house, Merlin way, North Weald, Epping, Essex, CM16 6hr t:
More informationDatasheet JIS Miniature Thermocouple Connector Quick Wire Sockets Types K, J, T, E, R/S & B (JIS Colour Code)
Datasheet JIS Miniature Thermocouple Connector Quick Wire Sockets Types K, J, T, E, R/S & B (JIS Colour Code) ENGLISH Miniature quick wire socket allowing rapid termination of wires Easy 'jab-in' connection,
More informationMIXING PUMP PFT G4 WE KEEP THINGS MOVING. Exterior plastering. Interior plastering. Liquid filler. Restoration mortar. Upgrated insulation
MIXING PUMP PFT G 4 MIXING PUMP PFT G4 Exterior plastering Interior plastering Mortar for door frames Liquid filler Restoration mortar Upgrated insulation over 60.000 30000 The mixing pump No. 1 PFT G
More informationPressure Booster System. Hya-Eco VP. Type Series Booklet
Pressure Booster System Hya-Eco VP Type Series Booklet Legal information/copyright Type Series Booklet Hya-Eco VP KSB Aktiengesellschaft Frankenthal All rights reserved. Contents provided herein must neither
More informationINSTRUCTION MANUAL Wardrobe lift 717
English Coatlift 717 Doc. No: M717 Edition: 1 Date: 2009-04-02 INSTRUCTION MANUAL Wardrobe lift 717 Granberg Interior AB Box 6112 SE-600 06 Norrköping SWEDEN For more information, see: www.granberg.se
More informationLK Manifold Cabinet UNI, LK Prefab Cabinet UNI
LK Manifold Cabinet UNI, LK Prefab Cabinet UNI Design The cabinets are designed to be installed into a wall or ceiling or externally on a wall. The minimum joist depth is 95 mm for UNI, 120 mm for UNI
More informationCompact. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram
Compact Video Complete Walkthrough Pre-Installation guide Prepare for your TopBrewer. A comprehensive step-by-step installation guide is available through your dealer, authorized installer or our website,
More informationJUPITER. Installation Manual. Revision
JUPITER Installation Manual Revision 2012.01.11 List of Contents Description of Manual Page 3 General Conditions page 4 Instruction 1 Control of Packing List page 5 Instruction 1.1 Jupiter Overview page
More informationK-FLEX SOLAR SYSTEM SOLAR SYSTEM
K-FLEX SOLAR SYSTEM SOLAR SYSTEM K-FLEX offers a line of products designed specifically for solar heating, renewable energy sources used to produce hot water using solar energy. The product range consists
More informationAssembly and users manual. Pallet racking Alfa
Assembly and users manual Pallet racking Alfa ASSEMBLING OF FRAMES Tightening Torque Screw M0 8.8 Max. tightening torque 7 Nm Taptite M6 Max. tightening torque 5 Nm Taptite M8 Max. tightening torque 5
More informationoptional parts for geberit Duofix carrier
geberit Duofix carrier.335.00.5 Installation accessories for concealed tank and carrier for wall-hung toilet. Accessories shall be for alternate frame installation and connection sets between carrier and
More informationAirBench EX Operation and Maintenance
AIRBENCH LTD AirBench EX Operation and Maintenance This Edition: 10 February 2016 AirBench Ltd, 14 Grange Farm Road, Colchester CO2 8JW www.airbench.com +44 (0) 1206 791191 Copyright AirBench Ltd 2016
More informationELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200
ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.
More informationOil lubricated vacuum pumps VE-O 5.2. Oilless vacuum pumps VP-T 5.6. Vacuum energy units VEE Vacuum flat tanks VSF 5.12
VACUUM GENERATORS Oil lubricated vacuum pumps VE-O.2 Oilless vacuum pumps VP-T.6 energy units VEE.10 flat tanks VSF.12 -controlled motor switching units VMS.14 g blowers VG-SD.16 blowers VG-D1.18 blowers
More information15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on
Features DIN rail mount or panel mount installation Dielectric strength: 4000 VAC High heat dissipation efficiency with ceramic PCB and integrated heatsink, random turn-on models available Input Indicator
More informationTGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series
Absorption Chillers TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Stable Chilled Water Outlet Temperature PID control is applied to maintain constant chilled water outlet temperature. When the cooling
More informationConergy SolarFamulus II
Conergy SolarFamulus II Installation manual www.conergy.com Table of Contents Table of Contents SolarFamulus II for universal use on flat roofs 1 Introduction 1 1.1 Short description 1 1.2 Intended use
More informationSealing and blister punching machines
Sealing and blister punching machines for MedTec, Dental, Watchmaking and Food industries ISO 9001:2008 EN ISO 13485:2012 Swiss Quality Products Hagmann Maschinenbau AG Bohnackerweg 6 CH- 2545 Selzach
More information09/04 Rev MANUAL Jumbo Stacker. Setup, Service
09/04 Rev. 3.00-02 MANUAL Setup, Service General... 2 Intended purpose... 2 Mode of operation... 2 System requirements... 3 Safety notes... 3 Setting up... 4 Positioning the stacker... 4 Setting the material
More informationProduct Datasheet. Hydraulic Dock Leveller with Telescopic Lip (PT) Load capacity: 150 KN ANSI NORM. Contact:
Product Datasheet Hydraulic Dock Leveller with Telescopic Lip (PT) Load capacity: 150 KN ANSI NORM Contact: 4/83 Boundary Rd Carrum Downs VIC 3201 Australia p: +61 (3) 87 877 877 e: innovation@ebs-building.com
More informationTender specification KLAUS Multiparking TrendVario 4300
Preliminary technical remarks 1. Basis for the design are: 1.1 the garage regulations (GaVo) according to the building regulations in the latest version, 1.2 the EC Machinery Directive 2006/42/EC, Appendix
More informationInstallation Instructions
Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720
More informationTechnical Specification. Wire Saw DS 271. Frame Agreement Appendix 3
Technical Specification Wire Saw DS 271 Meyer Burger AG Release: 23.02.09 Blo Allmendstrasse 86 / CH-3600 Thun Version: 02 Phone +41 (0) 33 439 05 05 / Fax +41 (0) 33 439 05 10 Part no.: 10007478 mbinfo@meyerburger.ch
More informationBINAR Quick-Lift System
BINAR Quick-Lift System Install and Training Original Document - July 1, 2015 1 What to expect The installation, set-up, and training process takes an average of 1.5 days (12 hours) per unit. On the first
More informationLUBRICATION PUMP Z2 CENTRAL LUBRICATION
LUBRICATION PUMP APPLICATION Lubrication pumps are used as a source of pressure lubricant in the circuits of two-line central lubrication systems. Pumps can be used for lubrication of high number of lubricated
More informationOrdering example: BKI-K90/SFR1.90T/B=1000xH=1000xH=1000xL=250. Standard damper length; special dimensions are available on request
Ordering example: Damper BKI-K90/SFR1.90T/B=1000xH=1000xH=1000xL=250 Standard damper length; special dimensions are available on request Dimensions B x H (width x height) in mm, side H = operating side
More informationMICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / /
3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 Harlow - Essex CM2 2DY, UK Data Sheet 6851 Page 1/7 MICROSTAT-M Particularities Electromechanical temperature
More informationOrdering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators
Conductive Level Controller CSM DS_E_1_ Automatic Water Supply and Drainage Control Ideal for level control of any conductive liquid. Compact plug-in controller for single- or two-point control of conductive
More informationServo-hydraulic Universal Testing Machine HUT Type B
Do Our Best for Your Test Servo-hydraulic Universal Testing Machine HUT Type B Load Frame Configuration: 6 columns, servo-controlled hydraulic Capacity: 300kN, 600kN, 1000kN, 3000kN Test Space: Dual zone
More informationHeat press PF-150C. Spare parts manual and machine diagrams. Author: MA Pagina 1 di 17 Edition: 05/2011 Replaces:
Author: MA Pagina 1 di 17 Heat press Author: MA Pagina 2 di 17 CONTENTS 0 PREFACE... 3 1 MACHINE IDENTIFICATION DATA... 4 1.1 IDENTIFICATION PLATE AND EC MARKINGS... 4 2 REGULATIONS AND GENERAL WARNINGS...
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation of your Agilent ICP-OES, please refer to this site preparation checklist. Correct site
More informationOPERATING MANUAL. Conveyor belts. CB-/B-Conveyor
OPERATING MANUAL Conveyor belts CB-/B-Conveyor Edition 1-5/2018 Contents Please note! -3 General Information -3 Validity of this manual and required compliance -3 How information is represented -4 For
More information