GCI60 Hampton Cast Iron Pellet Insert

Size: px
Start display at page:

Download "GCI60 Hampton Cast Iron Pellet Insert"

Transcription

1

2 CI60 Hampton Cast Iron Pellet Insert ¾ ¾ ¾

3 FI60 Wood Pellet Insert INSTALLED AS A FIREPLACE INSERT STOVE MODEL (FPI) / A INSTALLE COMME UN MODELE SUR PIED DE POELE. Minimum clearances to combustible materials./ Les dégagements minimums aux matériels combustibles: A Sidewall to center of unit (De la paroi au centre de l'unité) 24 (610 mm) B Sidewall to surround panel (De la paroi à l'entoure le panneau) 2 (51 mm) C Bottom of unit to an unshielded 12 (305 mm) mantle (Le fond de l'unité à un manteau de cheminée non blindé) 33 (838 mm) D Unit to top facing (protruding ¾ [19 mm]) (De l'unité au sommet du parement) 0 (0 mm) E Unit to side facing (protruding ¾ [19 mm]) (De l'unité au côté du parement) 0 (0 mm) F From door opening of unit to edge of floor protection (De la porte ouvrant au devant de protection de plancher) 6 (152 mm) From side of unit to edge of floor protection (De l'ouverture de porte pour prendre parti de protection de plancher) 6 (152 mm) Adjacent wall B A D E C These dimensions are minimum clearances. It is recommended that you Combustible ensure sufficient floors must room be protected for servicing, by a non-combustible routine cleaning material. and maintenance. - See Owners Manual. Le The plancher unit must combustible be installed doit être with a minimum protégé of 6 (152 par un mm) matériel of floor incombustible. protection in front - of Consultez and to the le manual. sides of the door opening. F

4 FI60 Wood Pellet Insert VENT TERMINATION REQUIREMENTS: IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Letter Minimum Clearance Description A 24 in (61 cm) Above grass, top of plants, wood, or any other combustible materials. B 48 in (122 cm) Beside/below any door or window that may be opened. (18 (46 cm) if outside fresh air installed.) C 12 in (30 cm) Above any door or window that may be opened. (9 (23 cm) if outside fresh air installed.) D 24 in (61 cm) To any adjacent building, fences and protruding parts of the structure. E 24 in (61 cm) Below any eave or roof overhang F 12 in (30 cm) To outside corner. 12 in (30 cm) To inside corner, combustible wall (vertical and horizontal terminations). H 3 ft (91 cm) within a height To each side of center line extended above natural gas or propane meter/ of 15 ft (4.5 m) above the regulator assembly or mechanical vent. meter/regulator assembly I 3 ft (91 cm) From any forced air intake of other appliance J 12 in (30 cm) Clearance to non-mechanical air supply inlet to building, or the combustion air inlet to any appliance. K 24 in (61 cm) Clearance above roof line for vertical terminations. L 7 ft (2.13 m) Clearance above paved sidewalk or paved driveway located on public property. K E D F Opens Opens B C B Termination Cap Air Supply Inlet A I as Meter Restriction Zone (Termination not allowed) H Opens L

5 FI60 Wood Pellet Insert OUTSIDE FRESH AIR CONNECTION Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures. When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 2 minimum (51 mm) ID (inside diameter) steel, aluminum or copper pipe should be used. It is recommended, when you are installing a fresh air system, to keep the number of bends in the pipe to a minimum. RECOMMENDED - THROUH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION NOTE - This venting configuration is only for use with the Built-In installation. Termination cap 90 elbow Wall framing Outside Wall Vertical section of vent pipe Wall strap 2" ID (51 mm) Optional Elbow Horizontal frame for thimble MASONRY FIREPLACE INSERT INSTALLATION Clean out tee Wall thimble Rain Cap Fresh-air intake Steel Plate or Flashing Damper Removed or Fastened Open Mantel (8" deep) Min. 8" from top of stove Clean-out tee If holes already exist fresh-air intake can be taken through the back of the fireplace or through the ash dump. Masonry Fireplace Min. 6" Floor Protection Combustible Floor

6 FI60 Wood Pellet Insert OUTSIDE VERTICAL INSTALLATIONS INSIDE VERTICAL INSTALLATIONS Rain cap Rain cap 24" (61 cm) Flashing 24" (61 cm) Flashing 3" (7.5 cm) Clearance 3" (7.5 cm) Clearance Support bracket Tee with cleanout Support bracket Type "L" vent Tee or 90 elbow Type "L" vent

female pipe. A Wall Support must be installed just above the tee and at least every 8 feet thereafter. If the pipe is to be run through a roof overhang then a Flashing, Storm Collar and Vertical Rain Cap

More information

TC54. for architects & designers. Dimensions Clearances Venting

TC54. for architects & designers. Dimensions Clearances Venting for architects & designers TC54 Series D Dimensions Clearances enting IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction

More information

TCWS54 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

TCWS54 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting FOR ARCHITECTS & DESIGNERS TCWS54 SERIES D2 Dimensions Clearances enting IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction

More information

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3.

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3. P36 - P36D Zero Clearance Direct Vent Gas Fireplace Model P36-NG4 P36-LP4 P36D-NG1 P36D-LP1 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3. kpa)

More information

Contemporary Collection

Contemporary Collection HZ5E Gas Fireplace Model HZE-NG HZ5E-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.9 kpa) Manifold Pressure - High 3.5 W.C. (.7 kpa) 1 W.C. (.9 kpa) Manifold Pressure

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES CHAPTER 10 CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3

More information

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw) P36 / P36E Gas Fireplace Model P36-NG10 P36-LP10 P36E-NG10 P36E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) 5 W.C. (1.25 kpa) 11

More information

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8. Model P36-NG10 P36-LP10 P36E-NG10 P36E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Gas Fireplaces P36-10 / P36E-10 Gas Fireplace Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa)

More information

Regency Horizon HZ30E Gas Fireplace

Regency Horizon HZ30E Gas Fireplace Specifications: Framing Dimensions: Model HZ3E-NG HZ3E-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent

More information

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection 1XTE-1 Gas Fireplace Model 1XTE-NG1 1XTE-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5 W.C. (.7 kpa) 1. W.C. (. kpa)

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES SECTION R1001 MASONRY FIREPLACES R1001.1 General. Masonry fireplaces shall be constructed in accordance with this section and the applicable provisions of Chapters 3 and 4. R1001.2 Footings and foundations.

More information

B36XTCE Gas Fireplace

B36XTCE Gas Fireplace Model B3XTCE-NG1 B3XTCE-LP1 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C./C.E. (1.5 kpa) 11 W.C./C.E. (.7 kpa) Manifold Pressure - High 3.5 W.C./C.E. (.7 kpa) 1 W.C./C.E. (.9 kpa) Manifold

More information

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth 28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1

More information

TC30 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

TC30 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting FOR RCHITECTS & DESIGNERS TC30 SERIES D Dimensions Clearances enting IMPORTNT This booklet is intended as a basic specifi cation guide for architects, designers and builders. Please refer to the Instruction

More information

Gas Fireplaces. B36XTE Gas Fireplace. Unit Dimensions with Vignette: Model B36XTE-NG10 B36XTE-LP10 M O S S. V Opening for gas connection

Gas Fireplaces. B36XTE Gas Fireplace. Unit Dimensions with Vignette: Model B36XTE-NG10 B36XTE-LP10 M O S S. V Opening for gas connection Model B36XTE-NG10 B36XTE-LP10 Fuel Type Natural Gas Propane Gas Fireplaces B36XTE Gas Fireplace Minimum upply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5 W.C. (0.87 kpa)

More information

Installation Instructions

Installation Instructions Installation Instructions SAVE THESE INSTRUCTIONS Please read this entire manual before you install and use your room heater. Failure to follow instructions may result in property damage, bodily injury,

More information

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE Model P33-NG10 P33-LP10 P33E-NG10 P33E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) Manifold

More information

for architects & designers

for architects & designers Fireplace and enting Specifications for architects & designers TC30 Series C IMPORTNT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the

More information

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth P33 Zero Clearance Direct Vent Gas Fireplace P33 WITH THE FLUSH OR BAY FRONT Model P33-NG4 P33-LP4 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure

More information

B41XTCE Gas Fireplace

B41XTCE Gas Fireplace B1XTCE Gas Fireplace Model B1XTCE-NG1 B1XTCE-LP1 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C./C.E. (1.5 kpa) 11 W.C./C.E. (.7 kpa) Manifold Pressure - High 3.5 W.C./C.E. (.7 kpa) 1 W.C./C.E.

More information

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. SAFETY PRECAUTIONS Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter

More information

for architects & designers

for architects & designers Fireplace and enting Specifications for architects & designers TCWS.38CE2 Series C MODULR DIRECT ENT FIREPLCE IMPORTNT This booklet is intended as a basic specification guide for architects, designers

More information

TC42 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

TC42 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting FOR RCHITECTS & DESIGNERS TC42 SERIES D Dimensions Clearances enting IMPOrTNT This booklet is intended as a basic specifi cation guide for architects, designers and builders. Please refer to the Instruction

More information

Light Stainless Flexible Liner

Light Stainless Flexible Liner Light Stainless Flexible Liner Dalsin Line light flexible liner is listed for chimney relining and is suitable for wood, pellet, gas, oil, and coal applications. This liner is manufactured using.006 thick

More information

TC36 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

TC36 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting FOR RCHITECTS & DESIGNERS TC36 SERIES D2 Dimensions Clearances enting IMPORTNT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction

More information

TC42 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

TC42 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting FOR RCHITECTS & DESIGNERS TC42 SERIES D2 Dimensions Clearances enting IMPORTNT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction

More information

Natural Gas Service Installation and Meter Clearance Requirements

Natural Gas Service Installation and Meter Clearance Requirements Natural Gas Service Installation and Meter Clearance Requirements Call SJG s new construction line at 1-844-611-5605 for more information. Builder/Owner/Developer Requirements The clearances in this handout

More information

for architects & designers

for architects & designers Fireplace and enting Specifications for architects & designers TC42 Outdoor Series C IMPORTNT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer

More information

Please consult the manufacturer s installation manual for all details and requirements before making a final design layout decision.

Please consult the manufacturer s installation manual for all details and requirements before making a final design layout decision. Please consult the manufacturer s installation manual for all details and requirements before making a final design layout decision. 72" Direct Vent Gas Fireplace MODEL FRONT HEIGHT WIDTH FRONT BACK WIDTH

More information

APPLICATION AND LISTING

APPLICATION AND LISTING DURALINER (SDL) 6"-8" DIAMETER (ROUND & OVAL) INSTALLATION INSTRUCTIONS MH14420 CMH1329 THESE INSTALLATION AND OPERATION INSTRUCTIONS COVER DURALINER MASONRY RELINING SYSTEM A MAJOR CAUSE OF CHIMNEY RELATED

More information

pellet stoves & inserts woo

pellet stoves & inserts woo www.regency-fire.com pellet woo stoves & inserts Greenfire GF55 pellet stove shown with antique nickel door overlay and ceramic log set. Greenfire GF55 Classic & Wood GFI55 Stove F1100, F2400, F3100, S2400

More information

Borough of Doylestown Building and Zoning Department

Borough of Doylestown Building and Zoning Department Borough of Doylestown Building and Zoning Department 57 West Court Street, Doylestown, PA 18901 215.345.4140 RESIDENTIAL BUILDING AND ZONING PERMIT APPLICATION PACKAGE BACKGROUND A building permit is required

More information

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

EPV Pellet Vent Pellet Stove Venting System Installation Instructions EPV Pellet Vent Pellet Stove Venting System Installation Instructions A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

Z-Vent Model SVE Series III

Z-Vent Model SVE Series III Special Stainless Steel Venting System for Gas Burning Appliances Category I, II, III, & IV Tested and Listed By Underwriters Laboratories Inc. UL 1738 & BH636 Note the following before installation of

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit HT-K - Horizontal Flue Gas System For GB125 Oil Condensing Boiler For trained and certified Installers Please read carefully prior to installation. 6

More information

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM C I NT ER T EK Wa r noc k CM He r sey US U L LISTED CAUTION: WEAR GLOES WHILE HANDLING SHEET METAL PARTS TO AOID PERSONAL INJURY. SHARP EDGES OR PROJECTIONS CAN CUT YOU. Selkirk DIRECT-TEMP Direct ent

More information

Chimney and Fireplace Inspection Report

Chimney and Fireplace Inspection Report Chimney and Fireplace Inspection Report 91406 Inspection prepared for: Mr. and Mrs. Client Inspector: Greg Butler 27943 Seco Canyon Road, 560, Santa Clarita, CA 91350 NOTICE TO THIRD PARTIES: This report

More information

TOWNSHIP OF FALLS USE & OCCUPANCY FACT SHEET

TOWNSHIP OF FALLS USE & OCCUPANCY FACT SHEET TOWNSHIP OF FALLS USE & OCCUPANCY FACT SHEET A CERTIFICATE OF USE & OCCUPANCY SHALL BE REQUIRED FOR ANY OF THE FOLLOWING REASONS: 1. Occupancy and Use of any building or portion thereof hereafter erected

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720

More information

GD Specifications

GD Specifications GD1-10 Specifications Information in this specification may be subject to change without notice. Please ensure you have the current version before beginning installation. 707 1,605 190 707 530 35 3 145

More information

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual Please see IB series product installation guide for details of installing the gas fire into this preformed metal cavity. Important: The appliance

More information

ENGLISH INSTALLATION INSTRUCTION MANUAL. N550 Bakers Oven. CERTIFIED for USA & CANADA SAFETY TESTED to UL & ULC-S

ENGLISH INSTALLATION INSTRUCTION MANUAL. N550 Bakers Oven. CERTIFIED for USA & CANADA SAFETY TESTED to UL & ULC-S ENGLISH INSTALLATION INSTRUCTION MANUAL Nectre Big Bakers Oven Operating Manual N550 Bakers Oven CERTIFIED for USA & CANADA SAFETY TESTED to UL 1482-2011 & ULC-S627-2000 CA O se re e re m efore r se r

More information

EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS

More information

PORTRAIT WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 569 Ledge Front

PORTRAIT WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 569 Ledge Front PORTRAIT 569 Ledge Front CSA approved for use with Valor Models 530I Heaters ONLY INSTALLATION INSTRUCTIONS! WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO

More information

GENERAL MECHANICAL SYSTEM REQUIREMENTS

GENERAL MECHANICAL SYSTEM REQUIREMENTS CHAPTER 13 GENERAL MECHANICAL SYSTEM REQUIREMENTS SECTION M1301 GENERAL M1301.1 Scope. The provisions of this chapter shall govern the installation of mechanical systems not specifically covered in other

More information

Installation GUIde Please read these instructions before proceeding

Installation GUIde Please read these instructions before proceeding Installation GUIde Please read these instructions before proceeding Installing your Earthfire is a relatively straight forward job, but there are several key aspects that may seem arbitrary to the general

More information

DOOR AND WINDOW OPENINGS PREPARE IN ADVANCE VBUCK CONSTRUCTION

DOOR AND WINDOW OPENINGS PREPARE IN ADVANCE VBUCK CONSTRUCTION DOOR AND WINDOW OPENINGS Openings for doors and windows are formed with bucks, or frames, which are constructed to the rough opening dimensions required for the doors and windows to be installed. These

More information

APPLICATION FOR FINISHED BASEMENT PERMIT

APPLICATION FOR FINISHED BASEMENT PERMIT APPLICATION FOR FINISHED BASEMENT PERMIT REAL ESTATE TAX I.D. #: - - _ - _ 7607 W College Drive Ph: (708) 361-1804 Fax: (708) 923-7112 building@palosheights.org APPLICANTS: COMPLETE ALL ITEMS AND SUBMIT

More information

Builder's Manual for Ortal Fireplaces

Builder's Manual for Ortal Fireplaces your life. your fire. Builder's Manual for Ortal Fireplaces Table of Contents 1. Introduction 2 2. Checklist 3 3. Model Firebox Clearances 4 4. General Guidelines 5 5. Heat Release and Air Intake 7 A.

More information

10 Fireplaces, Chimneys, and Flues

10 Fireplaces, Chimneys, and Flues 10 Fireplaces, Chimneys, and Flues Key Points Fireplaces must be designed and constructed to fulfill the following functions: - transfer structural loads to the surrounding soil or foundation wall; ensure

More information

Incinerator Systems NFPA 82 Inspection Form

Incinerator Systems NFPA 82 Inspection Form Incinerator Systems NFPA 82 Inspection Form PART 1 INCINERATORS DESIGN AND AUXILIARY FUEL ELECTRICAL SUPPLY AIR FOR COMBUSTION AND VENTILATION SPARK ARRESTERS 1. Are gas-burning installations designed

More information

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application DATE: / / PERMIT # REQUEST FOR: NEW BUILDING ADDITION REMODEL PLUMBING ONLY ELECTRIC ONLY

More information

Residential Building Inspections

Residential Building Inspections Residential Building Inspections Foundations, Grade Beams, Pile Caps, Foundation Pads 1. All trenches or excavations and formwork shall be in accordance with the size(s) and configuration(s) as per approved

More information

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section ) 8-1200. International Residential Code. ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section 6-9-40) NOTE-This article

More information

ATTENTION INSTALLING PERSONNEL

ATTENTION INSTALLING PERSONNEL DCVK-20 & DCVK-30 CONCENTRIC VENT TERMINATION KIT INSTALLATION INSTRUCTIONS Goodman Manufacturing Company, L.P. 2003-2007 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com

More information

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE

More information

PRE-ACCEPTANCE INSPECTION CHECKLIST

PRE-ACCEPTANCE INSPECTION CHECKLIST Avis au lecteur sur l accessibilité : Ce document est conforme au standard du gouvernement du Québec SGQRI 008-02 afin d être accessible à toute personne handicapée ou non. Toutes les notices entre accolades

More information

STEP-BY-STEP PLANS FOR CONSTRUCTING A 250 STICK ROCKET BARN (RBN 3.0) (see RBR plans for furnace and metal component construction)

STEP-BY-STEP PLANS FOR CONSTRUCTING A 250 STICK ROCKET BARN (RBN 3.0) (see RBR plans for furnace and metal component construction) STEP-BY-STEP PLANS FOR CONSTRUCTING A 250 STICK ROCKET BARN (RBN 3.0) (see RBR plans for furnace and metal component construction) DESIGNED BY PETER SCOTT DESIGN COPYRIGHT PETER SCOTT MAY 13, 2008 DESIGNED

More information

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory

More information

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service. CHAPTER3 Clark Public Utilities Commercial Electric Service Handbook Commercial Underground Services Preparing for the installation The following checklist will assist in preparing a project for the installation

More information

Gas meter clearances and service installation requirements

Gas meter clearances and service installation requirements FEBRUARY 2018 Gas meter clearances and service installation requirements CALL PSE S CUSTOMER CONSTRUCTION SERVICES AT 1-888-321-7779 OR VISIT PSE.COM/CUSTOMERCONSTRUCTION FOR MORE INFORMATION. Builder/owner/developer

More information

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. DuraFlex Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635. Specifications DuraFlex SW Applications DuraFlex SW smooth wall flexible relining for masonry chimney. Use with gas,

More information

Chimney Lining Systems

Chimney Lining Systems R Chimney Lining Systems Gas or Propane Fired Appliances Table of Contents 1. General Instructions and Warnings U.L. and Manufacturers Specifi cations...2 2. Types of Liner Systems...3 3. FLEXJET Installation

More information

Wood & Pellet ECONOMIZER STOVES & INSERTS

Wood & Pellet ECONOMIZER STOVES & INSERTS Wood & Pellet ECONOMIZER STOVES & INSERTS The Timberwolf Economizer EPA wood stoves provide an economical solution to rising costs of home heating. These clean burning, cost effective stoves deliver the

More information

Chapter 3. Chapter Overview

Chapter 3. Chapter Overview Chapter 3 Reading Floor Plans, Part 1: Floor Plan Symbols Chapter Overview Introduction to Reading Floor Plan Symbols Wall Symbols Door Symbols Window Symbols Schedules Cabinets, Fixtures, and Appliances

More information

City of New Hope Community Development 4401 Xylon Ave N New Hope MN Phone: Fax: newhopemn.gov

City of New Hope Community Development 4401 Xylon Ave N New Hope MN Phone: Fax: newhopemn.gov Mechanical/Utilities Heating systems The inspector shall visually inspect the heating system for the following conditions: o Excessive rust or discoloration of the draft hood o Signs of rust or deterioration

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS ULEB 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

The most versatile "BIG SCREEN" high efficiency fireplace!

The most versatile BIG SCREEN high efficiency fireplace! ZERO CLEARANCE (ZC) The most versatile "BIG SCREEN" high efficiency fireplace! Endless opportunities True polyvalence Enjoy high efficiency fires or the cozy ambiance of open fires. BBQ cooking. Water

More information

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y Installation Instructions Venting System For Pellet and Corn Stoves PelletVent Cornvent C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y A MAJOR CAUSE OF VENT RELATED

More information

METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner. Installation Instructions. Models

METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner. Installation Instructions. Models METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner Installation Instructions Models IPP Cat. I: Part 1 HEP Cat I, II, III, IV: Part 2 3STS This symbol shows that Cheminée Lining.E

More information

Engineering Design Center. Standard Drawings. 1st Edition -January 2016

Engineering Design Center. Standard Drawings. 1st Edition -January 2016 Engineering Design Center Standard Drawings 1st Edition -January 2016 Golden State Water Company Standard Drawings 1/11/2016 Table of Contents PART A STANDARD DRAWINGS Section I Pipeline Construction P-1

More information

For over 75 years, Main has manufactured domestic gas appliances designed to make life more affordable and comfortable for as many people as possible.

For over 75 years, Main has manufactured domestic gas appliances designed to make life more affordable and comfortable for as many people as possible. MAIN HE RANGE For over 75 years, Main has manufactured domestic gas appliances designed to make life more affordable and comfortable for as many people as possible. Today, Main is part of one of Europe

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS 150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS WARNING: THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F. TO ENSURE SAFETY THIS FLUE

More information

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7 Gas venting DIRECT VENT PRO CVS CHIMNEY LINER B-VENT CO-LINEAR CAPS Table of Contents DirectVent 4 x 6 5/8... 2 DirectVent 5 x 8... 4 DirectVent Pro Kits... 6 DirectVent CVS... 7 DirectVent Liner Kits...

More information

H-Body Sealants Guide

H-Body Sealants Guide H-Body Sealants Guide "Attention: The information contained in this sealant guide was created by Winnebago Industries, Inc. for manufacturing purposes. Sealing processes and the type of sealant used can

More information

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing

More information

Concentric Vent/Air System Supplement

Concentric Vent/Air System Supplement Concentric Vent/Air System Supplement This document is intended to be used by a qualified heating contractor or service technician. Read all instructions within this document and within the CHAL- LENGER

More information

Fireplaces and Chimneys

Fireplaces and Chimneys Philip Noah, IAAI-CFI, Mo State-CFI Fireplaces and Chimneys Arkansas IAAI-Fall Conference October 28, 2016 Fireplace Statistics U.S. Fire Administration categorizes fireplace fires in Heating Fires. The

More information

County of Yolo Development Services Building Inspection Division

County of Yolo Development Services Building Inspection Division County of Yolo Development Services Building Inspection Division 292 W. Beamer Street Woodland, CA. 95695 www.yolocounty.org (530) 666-8775 Mechanical Plan Review Comments Plan Review No. Owners Name Job

More information

Pumice - naturally better

Pumice - naturally better DISTRIBUTED BY APRIL 2008 Pumice - naturally better Pumice - - A naturally Natural Material better Pumice is a natural insulator. This is the unique property that separates pumice from all other chimney

More information

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION Ruling No. 05-08-1022 Application No. 2005-03 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF in Articles 9.10.14.1.

More information

SI T T FST

SI T T FST SI 440-600-700-700T-780-780T-900-1100 Freestanding TAPER TOP Open Fire - Wood Burner Installation Instructions Note: FLUE SYSTEMS Casing. Flue System may require to be Doubled Lined to Comply. Ref ASNZS:2918:2001

More information

CF-2100 SERIES FIREPLACES

CF-2100 SERIES FIREPLACES The Ultimate in Radiant Heating Systems CF-2100 SERIES FIREPLACES INSTALLATION MANUAL October, 2005 Crossfire Fireplaces 249 Bridge Street West, P.O. Box 121 Campbellford, Ontario, Canada K0L 1L0 Tel:

More information

SECTION LIGHTNING PROTECTION SYSTEM

SECTION LIGHTNING PROTECTION SYSTEM SECTION 16670 - LIGHTNING PROTECTION SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

NEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1

NEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1 MTA RR APPARATUS NEW ILLUMINATED LED SIGNAGE LIGHTWEIGHT REMOVABLE ALUMINUM PANEL FENCE 88 NORTH AVE CDR JOB NO. 60 NORTH AVE NORTH AVE CURRENT VIEW OF 88 NORTH AVENUE PROPOSED FACADE AT 88 NORTH AVENUE

More information

MASPORT I5000 INSERT FIRE, AUSTRALIAN MODEL

MASPORT I5000 INSERT FIRE, AUSTRALIAN MODEL MASPORT I5000 INSERT FIRE, AUSTRALIAN MODEL INSTALLATION INSTRUCTIONS Manufactured in New Zealand by: GLEN DIMPLEX AUSTRALASIA LIMITED PO Box 58-473 Botany Auckland 2163 Ph: 0800 666 2824 Fax: 09274 8472

More information

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits. SECTION 09 2216 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and

More information

SUPPLEMENTAL DRAWINGS

SUPPLEMENTAL DRAWINGS CITY OF GREATER SUDBURY SUPPLEMENTAL DRAWINGS TO THE ONTARIO PROVINCIAL STANDARD DRAWINGS Rev: February 2012 CITY OF GREATER SUDBURY STANDARD DRAWINGS TABLE OF CONTENTS Greater Sudbury Standard Drawings

More information

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Kodiak Wood Stove B Y : S H E R W O O D I N

More information

Masonry Thimble Chimney Serving Appliance

Masonry Thimble Chimney Serving Appliance Job #3097931 Masonry Thimble Chimney Serving Appliance Customer Name Location Address Location of the appliance in the home - Appliance Information 1A What type of appliance is installed? Stove 1B What

More information

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES Prepared By Office of State Fire Marshal Maine Office of Energy Resources 52 State House Station 55 Capital Street Augusta, ME 04333 Augusta,

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public

More information

HOME SYSTEMS CONSTRUCTION PROCEDURE

HOME SYSTEMS   CONSTRUCTION PROCEDURE HOME SYSTEMS WWW.QUICKBUILTHOMES.COM.AU CONSTRUCTION PROCEDURE INDEX - PARTS LIST PARTS LIST QBRC75(C) QBRM75C) QBSIPS75 QBRFSZ75C QBRFBC75C QBRF3030G QBRGSQC QBRFRC75C QBRFZEC QBRF4040C QBSACC75 QBFR7330WC

More information

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT. DuraPlus ll-fuel, triple-wall chimney system. UL 103 HT. Specifications pplications DuraPlus himney is a triple-wall, all-fuel chimney for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges,

More information

SI T T FSS/FSTT Open Fire

SI T T FSS/FSTT Open Fire SI 440-600-700-700T-780-780T-900-1100 FSS/FSTT Open Fire Freestanding Solid Fuel Burner - Indoor Open Wood Fire Available in Square Top or Taper Top Options Installation Instructions Note: Flue System

More information

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing

More information