Multiple Response Optimization of Tuned Mass Dampers
|
|
- Eustace Rudolf Cummings
- 6 years ago
- Views:
Transcription
1 Multiple Response Optimization of Tuned Mass Dampers SİNAN MELİH NİGDELİ Department of Civil Engineering Istanbul University 33 Avcılar, Faculty of Engineering, Istanbul, Turkey TURKEY GEBRAİL BEKDAŞ Department of Civil Engineering Istanbul University 33 Avcılar, Faculty of Engineering, Istanbul, Turkey TURKEY Abstract: The optimum parameters of Tuned Mass Damper (TMDs) in seismic control of structure may be different according to the desired objective function in optimization. While a response of the structure under an excitation is optimally reduced, another responses or the same response under a different excitation may not be sufficiently reduced. For that reason, a multiple response optimization is proposed for the problem. The proposed method employs a music-inspired metaheuristic algorithm called Harmony Search. The method is feasible in order to reduce the objective function which is the average of maximum displacement, velocity and acceleration of all stories under different excitations. Key-Words: Tuned mass damper, Optimization, Multiple response, Harmony search, Metaheuristic. Introduction Tuned mass dampers (TMDs) are vibration absorber devices which are also used in civil structures subjected to wind and earthquake effects. The main aim in the design of TMDs is to tune the parameters of TMD according to the characteristics of the main structure. In order to find optimum TMD parameters such as mass (or mass ratio), period (or stiffness) and damping ratio (or damping coefficient), several numerical algorithms have been employed [ 9]. Most of these algorithms are metaheuristic algorithms which are inspired from several processes or behavior of organisms. By using these algorithms, TMDs are optimized according to responses of the main structure in time or frequency domain. This paper proposes a multiple response optimization for TMDs. In this approach, an objective function which is the ratio of sum of the responses of the structure with and without TMD, is used. This objective function considers all story responses and excitations of six different ground motions. Also, displacements, velocities and accelerations are also considered. Methodology Harmony search (HS) algorithm is employed in the optimization process. HS is a metaheuristic algorithm inspired from musical processes []. It uses randomly assigned numbers in order to reach the optimum solution. HS has special rules in generation of randomization. A solution set can be constructed from the initial range of parameters or existing sets can be used in the construction of new set. Thus, local optima problem is prevented. The methodology involves dynamic analyses of shear building for each iterations of optimization process. First, properties of structures, HS parameters, earthquake records and a possible solution range are defined. Then, the structure without TMD is analyzed for comparisons of objective function. The initial harmony memory matrix (HM) containing harmony vectors (HVs) are generated. HVs contain design variables such as ISBN:
2 mass, period and damping ratio of TMD and the numbers of HVs are defined with Harmony Memory Size (HMS). The design variables are randomly chosen from the selected range. After the generation of initial harmony memory matrix, a new HV is generated by using the same procedure or an existing vector in HM with a possibility defined as Harmony Memory Considering Rate (HMCR). The solution range is limited with a parameter called Pitch Adjacent Rate (PAR) if generation is done around an existing vector. The worst vector is replaced with the newly generated HV. The worst one is chosen according to the objective function and iterative generation of new HVs continue until the objective function is higher than the user defined value. The objective function is average of the maximum value of displacement, velocity and acceleration of all stories of structure under six different earthquake records. 3 Numerical Examples As a numerical example, a -storey building was investigated []. The mass of the each story is 98 tons. The stiffness coefficients (k) of the stories are linearly decreased from 3 MN/s to 998 MN/s by the increase of the story numbers. The damping coefficients (c) are. times of the stiffness coefficients. The six different earthquake records used in the study are KJM, PET9, ERZ-NS, LGP, RRS8 and SYL3 records of, Cape Mondecino,, Loma Prieata and Northridge (last records) earthquakes. An optimum TMD was searched for the following ranges. This ranges are %-% for mass ratio, %- 3% for damping ratio and.8 s-. s for period of TMD. The optimum mass, period and damping ratio of TMD were found as 38 t, 3.3 s and.9, respectively. Top storey displacement (x ), velocity and acceleration including ground acceleration (a g ) plots are given in Fig. -3, respectively... x x x x x x Fig.. Top story displacements 3 ISBN:
3 TABLE I. THE MAXIMUM RESPONSES FOR STRUCTURE WITHOUT TMD Earthquakes PET9 KJM ERZ-NS RRS8 SYL3 LGP displacement velocity (m/s) acceleration (m/s ) TABLE II. THE MAXIMUM RESPONSES FOR STRUCTURE WITH TMD Earthquakes PET9 KJM ERZ-NS RRS8 SYL3 LGP displacement velocity (m/s) acceleration (m/s ) dx - dx dx dx dx - dx -3 3 Fig.. Top story velocities - 3 ISBN:
4 d x /dt + a g (m/s ) - - d x /dt + a g (m/s ) d x /dt + a g (m/s ) d x /dt + a g (m/s ) d x /dt + a g (m/s ) d x /dt + a g (m/s ) - 3 Fig. 3. Top story accelerations - 3 The maximum responses of structures under optimization earthquakes are given in Table and for structures without and with TMD, respectively. The maximum displacement of the structure without TMD is.73 m and this displacement occurs under excitation. The optimum TMD is effective to reduce this displacement to. m (3.% reduction). As seen in Fig., the optimum TMD is effective to reduce peak displacements and to obtain a steady state response. The same behaviour is also seen for velocities and accelerations. Conclusion According to the results, optimum TMD is effective to reduce the objective function by.3%. Separately, the optimum TMD can reduce maximum displacement, velocity and acceleration for the most critical earthquake excitation by 3.%, 38.7% and.%,respectively. According to these results, the optimum TMD is not effective only for a single response of the structure. The proposed method is feasible in order to find a general optimum result which is acceptable for different responses of all stories under multiple ground motions. References: [] F. Sadek, B. Mohraz, A.W. Taylor, R.M. Chung, A method of estimating the parametersdof tuned mass dampers for seismic applications, Earthq. Eng. Struct. D.,vol., pp. 7-3, 997. [] R. Rana, T. T. Soong, Parametric study and simplified design of tuned mass dampers, Engineering Structures, Vol., 998, pp. 93. ISBN:
5 [3] C. C. Chang, Mass dampers and their optimal designs for building vibration control, Engineering Structures, Vol., 999, pp [] M. N. S. Hadi, Y. Arfiadi, Optimum design of absorber for MDOF structures, Journal of Structural Engineering-ASCE, Vol., 998, pp [] G. C. Marano, R. Greco, B. Chiaia, A comparison between different optimization criteria for tuned mass dampers design, Journal of Sound and Vibration, Vol. 39,, pp [] A. Y. T. Leung, H. Zhang, C. C. Cheng, Y. Y. Lee, Particle swarm optimization of TMD by non-stationary base excitation during earthquake, Earthquake Engineering and Structural Dynamics, Vol. 37, 8, pp. 3-. [7] A. Y. T. Leung, H. Zhang, H., Particle swarm optimization of tuned mass dampers, Engineering Structures, Vol. 3, 9, pp [8] G. Bekdaş, S.M. Nigdeli, Estimating Optimum Parameters of Tuned Mass DampersUsing Harmony Search, Eng. Struct., vol. 33, pp. 773,. [9] R. Steinbuch, Bionic optimisation of the earthquake resistance of high buildings by tunedmass dampers, J. Bionic Eng., vol. 8, pp. 33-3,. [] Z.W. Geem, J.H. Kim, G.V. Loganathan, A new heuristic optimization algorithm: harmony search, Simul.,vol.7, pp. -8,. [] M.-Y. Liua, W.-L. Chiangb, J.-H. Hwangb, C.-R. Chub, Wind-induced vibration of highrise building with tuned mass damper including soilstructure interaction, Journal of Wind Engineering and Industrial Aerodynamics,vol. 9, pp. 9, 8. ISBN:
Seismic Analysis of Structure by Introducing Weak Story on Top as Tuned Mass Damper
Seismic Analysis of Structure by Introducing Weak Story on Top as Tuned Mass Damper Dr. S.A. Halkude 1, Mr. C.G.Konapure 2, Vanishri. S. Kulkarni 3 1,2,3 Department of Civil Engineering, Walchand Institute
More informationSTFT Based Real-time Control with Variable Stiffness
STFT Based Real-time Control with Variable Stiffness and Damping of Tuned Smart Mass Tuned Damper Mass in Damper and Damping for Seismic Protection C.Sun Department of Civil and Environmental Engineering,
More informationA Strategy for the Optimization of Damper Configurations based on Building Performance Indices
A Strategy for the Optimization of Damper Configurations based on Building Performance Indices Wei Wanda Liu Department of Civil, Structural & Environmental Engineering, University at Buffalo Research
More informationOptimization of Reinforced Concrete Frames by Harmony Search Method
11 th World Congress on Structural and Multidisciplinary Optimisation 07 th -12 th, June 2015, Sydney Australia Optimization of Reinforced Concrete Frames by Harmony Search Method Moacir Kripka, Deise
More informationSEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES
SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES G.S. Balakrishna 1, Jini Jacob 2 1 (Department of Civil Engineering, SSET/ M G University, India) 2 (Department of Civil
More informationPERFORMANCE OF TUNED MASS DAMPERS FOR RESPONSE REDUCTION OF STRUCTURES UNDER NEAR-FIELD AND FAR-FIELD SEISMIC EXCITATIONS
4th International Conference on Earthquake Engineering Taipei, Taiwan October 12-13, 2006 Paper No. 112 PERFORMANCE OF TUNED MASS DAMPERS FOR RESPONSE REDUCTION OF STRUCTURES UNDER NEAR-FIELD AND FAR-FIELD
More informationEffectiveness of Tuned Mass Dampers in Mitigating Earthquake Ground Motions in Low and Medium Rise Buildings
Journal of Engineering and Architecture December 2016, Vol. 4, No. 2, pp. 11-27 ISSN: 2334-2986 (Print), 2334-2994 (Online) Copyright The Author(s). All Rights Reserved. Published by American Research
More informationSEISMIC EFFECTIVENESS OF TUNED MASS DAMPER (TMD) FOR DIFFERENT GROUND MOTION PARAMETERS
13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 2325 1 SEISMIC EFFECTIVENESS OF TUNED MASS DAMPER (TMD) FOR DIFFERENT GROUND MOTION PARAMETERS Dr. Mohan
More informationEffectiveness of Tuned Liquid Column Dampers on Vibration Behavior of One-story Steel Structure under Harmonic Force and an Earthquake Record
Australian Journal of Basic and Applied Sciences, 6(13): 41-47, 2012 ISSN 1991-8178 Effectiveness of Tuned Liquid Column Dampers on Vibration Behavior of One-story Steel Structure under Harmonic Force
More informationSeismic Vibration Control of a MDOF Building Connected with Viscous and SAVFD Dampers
International Journal of Scientific and Research Publications, Volume 5, Issue 7, July 215 1 ISSN 225-3153 Seismic Vibration Control of a MDOF Building Connected with Viscous and SAVFD Dampers Mr. Muralidhara
More informationPerformance of Tuned Mass Dampers in Vibration Response Control of Base-Excited Structures
Journal of Civil, Construction and Environmental Engineering 2017; 2(3): 87-94 http://www.sciencepublishinggroup.com/j/jccee doi: 10.11648/j.jccee.20170203.11 Performance of Tuned Mass Dampers in Vibration
More informationEQUIVALENT UNIFORM DAMPING RATIOS for Irregular in Height Concrete / Steel Structural systems
EUROSTEEL 2008, 3-5 September 2008, Graz, Austria 1485 EQUIVALENT UNIFORM DAMPING RATIOS for Irregular in Height Concrete / Steel Structural systems A.V. Papageorgiou a, C.J. Gantes a a National Technical
More informationAn Experimental Investigation on Dynamic Response Control of Structures using Tuned Liquid Column Damper
An Experimental Investigation on Dynamic Response Control of Structures using Tuned Liquid Column Damper Supradip Saha a, Rama Debbarma b, Member, ASCE a- M.Tech Scholar, b- Associate Professor Department
More informationTitle. Author(s)M. OHSAKI; S. TSUDA; N. SUGIYAMA. Issue Date Doc URL. Type. Note. File Information DIRECTIONAL SEISMIC VIBRATION CONTROL
Title PARAMETER OPTIMIZATION OF GEOMETRICALLY NONLINEAR TU DIRECTIONAL SEISMIC VIBRATION CONTROL Author(s)M. OHSAKI; S. TSUDA; N. SUGIYAMA Issue Date 2013-09-11 Doc URL http://hdl.handle.net/2115/54200
More informationInvestigating the Effect of Pounding on Seismic Response of Isolated Structures
Investigating the Effect of Pounding on Seismic Response of Isolated Structures Saeed Hedayat Department of Civil Engineerin, uneversity of guilan, Rasht, Iran Abstract: Some investigations have been conducted
More informationA Comparison between a New Semi-Active Tuned Mass Damper and an Active Tuned Mass Damper
Available online at www.sciencedirect.com Procedia Engineering 14 (2011) 2779 2787 The Twelfth East Asia-Pacific Conference on Structural Engineering and Construction A Comparison between a New Semi-Active
More informationDESIGN OF OPTIMUM PARAMETERS OF TUNED MASS DAMPER FOR A G+8 STORY RESIDENTIAL BUILDING
International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-56 Volume: 5 Issue: 11 Nov 218 www.irjet.net p-issn: 2395-72 DESIGN OF OPTIMUM PARAMETERS OF TUNED MASS DAMPER FOR A G+8
More informationDYNAMIC ANALYSIS OF 25 STOREY RCC BUILDING WITH AND WITHOUT VISCOUS DAMPERS. Naziya Ghanchi1, Shilpa Kewate2
International Journal of Scientific & Engineering Research, Volume 6, Issue 12, December-215 DYNAMIC ANALYSIS OF 25 STOREY RCC BUILDING WITH AND WITHOUT VISCOUS DAMPERS Naziya Ghanchi1, Shilpa Kewate2
More informationAN EXPERIMENTAL INVESTIGATION OF A MULTIPLE-TUNED- MASS-DAMPER-STRUCTURE SYSTEM WITH SOIL-STRUCTURE INTERACTION
AN EXPERIMENTAL INVESTIGATION OF A MULTIPLE-TUNED- MASS-DAMPER-STRUCTURE SYSTEM WITH SOIL-STRUCTURE INTERACTION Raz JABARY and Gopal MADABHUSHI ABSTRACT A tuned mass damper (TMD) is a popular vibration
More informationSeismic Response Reduction of a Building Using. Top-Story Isolation System with MR Damper
Contemporary Engineering Sciences, Vol. 7, 04, no., 979-986 HIKARI Ltd, www.m-hikari.com http://dx.doi.org/0.988/ces.04.493 Seismic Response Reduction of a Building Using Top-Story Isolation System with
More informationBEHAVIOUR OF SOIL-STRUCTURE SYSTEM WITH TUNED-MASS DAMPERS DURING NEAR-SOURCE EARTHQUAKES
13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 24 Paper No. 1353 BEHAVIOUR OF SOIL-STRUCTURE SYSTEM WITH TUNED-MASS DAMPERS DURING NEAR-SOURCE EARTHQUAKES Nawawi CHOUW
More informationFULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES
FULL-SCALE VERIFICATION TEST OF DYNAMIC RESPONSE CONTOROL TECHNIQUES FOR STRONG EARTHQUAKES Hirokazu IEMURA 1, Akira IGARASHI 2, Torajiro FUJIWARA 3 And Akihiro TOYOOKA 4 SUMMARY In order to verify the
More informationROBUST DESIGN OF TMD SYSTEMS FOR THE SEISMIC RESPONSE CONTROL OF ASYMMETRIC SOFT STOREY BUILDING
The 4 th World Conference on Earthquake Engineering October -7, 8, Beijing, China ROBUST DESIGN OF TMD SSTEMS FOR THE SEISMIC RESPONSE CONTROL OF ASMMETRIC SOFT STORE BUILDING Nirmalendu Debnath, S.K.
More informationIrrigation network design and reconstruction and its analysis by simulation model
SSP - JOURNAL OF CIVIL ENGINEERING Vol. 9, Issue 1, 2014 DOI: 10.2478/sspjce-2014-0001 Irrigation network design and reconstruction and its analysis by simulation model Milan Čistý, Zbynek Bajtek, Anna
More informationOPTIMUM DESIGN OF TMD SYSTEM FOR TALL BUILDINGS
INTERNATIONAL JOURNAL OF OPTIMIZATION IN CIVIL ENGINEERING Int. J. Optim. Civil Eng., 2012; 2(4):511-532 OPTIMUM DESIGN OF TMD SYSTEM FOR TALL BUILDINGS A. Abdelraheem Farghaly *, Faculty of Industrial
More informationChapter 3 Passive Protective Schemes for Rail- Counterweight System
Chapter 3 Passive Protective Schemes for Rail- Counterweight System The analyses in the previous chapter have shown that the rail-counterweight systems are vulnerable to overstressing of the guide rails
More informationIJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):
IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online): 2321-0613 Experimental Investigation of Effect of Tuned Mass Damper in the Structure using Shake
More informationEarthquake Analysis of Tall Building with Tuned Mass Damper.
Earthquake Analysis of Tall Building with Tuned Mass Damper. Mr. Ashish A. Mohite 1, Prof. G.R. Patil 2 1 (M.E. (Structure) Student, Department of Civil Engineering Rajarshi Shahu College of Engineering,
More informationSeismic Response of Low-Rise Base Isolated Structures
Seismic Response of Low-Rise Base Isolated Structures E. Aydin, B. Ozturk & O.F. Kilinc Department of Civil Engineering, Faculty of Engineering Nigde University, Nigde, 51100, TURKEY ABSTRACT: Effects
More informationInternational Journal of Advance Engineering and Research Development DYNAMIC RESISTANCE OF TALL BUILDINGS BY USING TUNED MASS DAMPER S A REVIEW
Scientific Journal of Impact Factor(SJIF): 3.134 International Journal of Advance Engineering and Research Development Volume 2,Issue 10, October-2015 e-issn(o): 2348-4470 p-issn(p): 2348-6406 DYNAMIC
More informationHyun-Su Kim Division of Architecture, Sunmoon Univ., Asan, , Korea,
EACWE 5 Florence, Italy 19 th 3 rd July 009 Flying Sphere image Museo Ideale L. Da Vinci Fuzzy hybrid control of wind response in a tall building using a smart tuned mass damper Hyun-Su Kim Division of
More informationOptimal Performance-based
BUILDING CONTROL WITH PASSIVE DAMPERS Optimal Performance-based Design for Earthquakes Izuru Takewaki Kyoto University, Japan TECHNISCHE INFORMATIONSBIBLIOTHEK UNIVERSITATSBIBLIOTHEK HANNOVER \ / John
More informationDynamics of structures
Dynamics of structures 4.Multiple degree of freedom systems Arnaud Deraemaeker (aderaema@ulb.ac.be) 1 Outline of the chapter *Multiple degree of freedom systems in real life Hypothesis Examples *Response
More informationSEISMIC RESPONSE OF MULTISTOREYED STEEL FRAME WITH VISCOUS FLUID SCISSOR JACK DAMPERS
International Journal of Civil Engineering and Technology (IJCIET) Volume 8, Issue 8, August 2017, pp. 289 312, Article ID: IJCIET_08_08_032 Available online at http://http://ww www.iaeme.com/ijciet/issues.asp?jtype=ijciet&v
More informationPerformance Improvement of Tall Reinforced Concrete Structures with Multiple Tuned Mass Dampers (MTMD)
Performance Improvement of Tall Reinforced Concrete tructures with Multiple Tuned Mass Dampers (MTMD) M. hooshtari Department of Civil Eng., Bu Ali ina University, Hamedan, Iran. H. Mortezaie Department
More informationSeismic Response Control of the Building using Passive Devices
INSTITUTE OF TECHNOLOGY, NIRMA UNIVERSITY, AHMEDABAD 382 481, 08-10 DECEMBER, 2011 1 Seismic Response Control of the Building using Passive Devices Vijay Chachapara, Sharadkumar Purohit and P. V. Patel
More informationISSN Vol.05,Issue.10, May-2016, Pages:
ISSN 2319-8885 Vol.05,Issue.10, May-2016, Pages:2079-2089 www.ijsetr.com Analysis and Design of Multi Storied Building for Vertical and Horizontal Loading With and Without Dampers using SAP2000 HAITHAM
More informationInvestigation of Seismic Response of Steel MRF Building Structures with Nonlinear Viscous Dampers Using Real- Time Hybrid Simulation
NHERI Lehigh Experimental Facility Researchers Workshop: Advanced Simulation for National Hazards Mitigation December 5 6, 2016 Investigation of Seismic Response of Steel MRF Building Structures with Nonlinear
More informationDynamic Analysis of High Rise Seismically Isolated Buildings
American Journal of Civil Engineering 2015; 3(2): 43-50 Published online March 10, 2015 (http://www.sciencepublishinggroup.com/j/ajce) doi: 10.11648/j.ajce.20150302.13 ISSN: 2330-8729 (Print); ISSN: 2330-8737
More informationStructural Control of RC Buildings Subjected to Near-Fault Ground Motions in terms of Tuned Mass Dampers
Structural Control of RC Buildings Subjected to Near-Fault Ground Motions in terms of Tuned Mass Dampers Hosein Naderpour 1 *, Arian Kiani 2, and Ali Kheyroddin³ 1. Associate Professor, Faculty of Civil
More informationApplication of Endurance Time Method in Structural Optimization of the Dampers for Seismic Design
Application of Endurance Time Method in Structural Optimization of the Dampers for Seismic Design H. Amouzegar, H. Tajmir Riahi & M. Daei University of Isfahan, Iran SUMMARY: Optimization techniques help
More informationMulti-storey structures with compound seismic isolation
Earthquake Resistant Engineering Structures VII 207 Multi-storey structures with compound seismic isolation M. C. Phocas & G. Pamboris Department of Civil and Environmental Engineering, University of Cyprus,
More informationVibration Control by Tuned Liquid Dampers
Vibration Control by Tuned Liquid Dampers Motive Construction of tall structures in regions around the world where earthquakes and extreme-wind conditions take place have been a concern to structural engineers.
More informationSeismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers
RESEARCH ARTICLE OPEN ACCESS Seismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers Yuvraj Bisht*, Saraswati Setia** *(Department of Civil Engineering, NIT Kurukshetra, Haryana, INDIA
More informationDynamic Time History Analysis of Plane Frame with Tuned Mass Considering Soil-Structure Interaction
١ Dynamic Time History Analysis of Plane Frame with Tuned Mass Damper by Considering Soil-Structure Interaction S. M. Mirhoseini hezaveh Civil Engineering Department, Islamic Azad University Arak Branch
More informationSeismic Control of Continuous Bridges Using Variable Radius Friction Pendulum Systems and Viscous Fluid Dampers
Seismic Control of Continuous Bridges Using Variable Radius Friction Pendulum Systems and Viscous Fluid Dampers A. Krishnamoorthy Department of Civil Engineering, Manipal Institute of Technology, Manipal,
More informationSEISMIC RESPONSE ANALYSIS OF VERTICALLY IRREGULAR RC BUILDINGS USING LAMINATED RUBBER BEARING
SEISMIC RESPONSE ANALYSIS OF VERTICALLY IRREGULAR RC BUILDINGS USING LAMINATED RUBBER BEARING Aboli A. Deshpande 1, S. B. Shinde, S. M. Dumne 3 1 Post graduate student, Civil Engg. Department, Jawaharlal
More informationSeismic analysis of parallel structures coupled by lead extrusion dampers
Int J Adv Struct Eng (17) 9:177 19 DOI 1.17/s91-17-157-x ORIGINAL RESEARCH Seismic analysis of parallel structures coupled by lead extrusion dampers C. C. Patel 1 Received: 7 October 16 / Accepted: 9 April
More informationSeismic retrofitting of buildings using energy dissipation devices
Technion Israel Institute of Technology Aim of the talk Present ongoing research in which the presenter has been involved. Various types of will be discussed. Various structural systems (e.g. frames, walls
More informationA NOVEL MULTIOBJECTIVE OPTIMIZATION ALGORITHM, MO HSA. APPLICATION ON A WATER RESOURCES MANAGEMENT PROBLEM
A NOVEL MULTIOBJECTIVE OPTIMIZATION ALGORITHM, MO HSA. APPLICATION ON A WATER RESOURCES MANAGEMENT PROBLEM I. Kougias 1, L. Katsifarakis 2 and N. Theodossiou 3 Division of Hydraulics and Environmental
More informationEFFECT OF FLUID VISCOUS DAMPERS IN MULTI-STOREYED BUILDINGS
IMPACT: International Journal of Research in Engineering & Technology (IMPACT: IJRET) ISSN(E): 2321-8843; ISSN(P): 2347-4599 Vol. 2, Issue 9, Sep 2014, 59-64 Impact Journals EFFECT OF FLUID VISCOUS DAMPERS
More informationTuned Mass Damper Positioning Effects on the Seismic Response of a Soil-MDOF-Structure System
Journal of Earthquake Engineering ISSN: 1363-2469 (Print) 1559-808X (Online) Journal homepage: http://www.tandfonline.com/loi/ueqe20 Tuned Mass Damper Positioning Effects on the Seismic Response of a Soil-MDOF-Structure
More informationCOMPARISON OF DIFFERENT METHODS FOR SEISMIC RETROFIT OF BRIDGES USING SMART MATERIALS
13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 274 COMPARISON OF DIFFERENT METHODS FOR SEISMIC RETROFIT OF BRIDGES USING SMART MATERIALS Bassem ANDRAWES
More informationEffects of Friction Damper-brace Design Parameters on Seismic Performance of Multistory Building Structures
Research Journal of Environmental and Earth Sciences 6(5): 299-306, 2014 ISSN: 2041-0484; e-issn: 2041-0492 Maxwell Scientific Organization, 2014 Submitted: February 18, 2014 Accepted: March 08, 2014 Published:
More informationIntroduction to Earthquake Engineering Introduction to Seismic Control
Introduction to Earthquake Engineering Introduction to Seismic Control Prof. Dr.-Ing. Uwe E. Dorka published: October 2014 Introduction Conventional Structures can be earthquake safe, but they are not
More informationExperimental Study on a Tuned-Mass Damper of Offshore for Vibration Reduction
Journal of Physics: Conference Series PAPER OPEN ACCESS Experimental Study on a Tuned-Mass Damper of Offshore for Vibration Reduction To cite this article: Qiong Wu et al 06 J. Phys.: Conf. Ser. 744 0045
More informationStudy of TMD-controlled Reinforced Concrete Framed Structure under Code-based Artificial Earthquake
Rev. Téc. Ing. Univ. Zulia. Vol. 37, Nº 1, 42-48, 214 Study of TMD-controlled Reinforced Concrete Framed Structure under Code-based Artificial Earthquake Min-Ho Chey School of Architecture & Art, Yanbian
More informationEARTHQUAKE RESPONSE ANALYSIS OF MID-STORY BUILDINGS ISOLATED WITH VARIOUS SEISMIC ISOLATION TECHNIQUES
EARTHQUAKE RESPONSE ANALYSIS OF MID-STORY BUILDINGS ISOLATED WITH VARIOUS SEISMIC ISOLATION TECHNIQUES N. Torunbalci 1 and G. Ozpalanlar 2 1 Assoc. Professor Dr., Dept. of Structural Engineering, Faculty
More informationConventional Design Approach Structures : To resist earthquake through strength, ductility & energy absorption Excitations : Inelastic deformation of
Earthquake Response of Seismically Isolated Bridges Suhasini Madhekar College of Engineering Pune Faculty Development Program on Fundamentals of Structural Dynamics and Application to 7 th Earthquake Engineering
More informationUsing Harmony Search for Optimising University Shuttle Bus Driver Scheduling for Better Operational Management
Available online at www.globalilluminators.org GlobalIlluminators Full Paper Proceeding ITMAR -2014, Vol. 1, 614-621 FULL PAPER PROCEEDING Multidisciplinary Studies ISBN: 978-969-9948-24-4 ITMAR-14 Using
More informationDouble Skin Facade Integrated Damping Systems for Tall Buildings Kyoung Sun Moon School of Architecture Yale University, New Haven, CT, USA
http://dx.doi.org/10.117/ijiet.91.05 Double Skin Facade Integrated Damping Systems for Tall Buildings Kyoung Sun Moon School of Architecture Yale University, New Haven, CT, USA Abstract - As buildings
More informationSTRENGTH REDUCTION FACTORS FOR MULTI-DEGREE-OF-FREEDOM SYSTEMS
STRENGTH REDUCTION FACTORS FOR MULTI-DEGREE-OF-FREEDOM SYSTEMS Perla R SANTA-ANA 1 And Eduardo MIRANDA 2 SUMMARY Strength reduction factors of multi-degree-of-freedom (MDOF) structures are investigated.
More informationVery Low Seismicity Areas
Vol. XIX, 2011, No. 3, 1 9 M. Sokol, L. Konečná, M. Čuhák, M. Dallemule Very Low Seismicity Areas in Slovakia and Comparison of Seismic Risks in Central European Countries Milan SOKOL milan.sokol@stuba.sk
More informationSeismic Performance of TMDs in Improving the Response of MRF Buildings
Scientia Iranica, Vol. 15, No. 1, pp 21{33 c Sharif University of Technology, February 2008 Seismic Performance of TMDs in Improving the Response of MRF Buildings S.M. Zahrai and A. Ghannadi-Asl 1 In this
More informationISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 4, July 2013
Vibration Control of Uniformly Tapered Chimney by Using Tuned Mass Damper INGALE S. D., MAGDUM M. M. 1. PG student, civil department, Sinhgad College of Engineering, Pune 2. Professor, Civil Department,
More informationEffective Viscous Damping Ratio in Seismic Response of Reinforced Concrete Structures
6 th International Conference on Advances in Experimental Structural Engineering 11 th International Workshop on Advanced Smart Materials and Smart Structures Technology August 1-2, 2015, University of
More informationUsing friction dampers for improving earthquake response of self-variable stiffness RC framed buildings
Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings I. Iskhakov & Y. Ribakov Department of Civil Engineering, Ariel University Center of Samaria, Israel
More informationK. Ikago 1, N. Inoue 2 1. INTRODUCTION 2. THE CONCEPT OF DISPLACEMENT CONTORL DESIGN
6 th International Conference on Advances in Experimental Structural Engineering th International Workshop on Advanced Smart Materials and Smart Structures Technology August -, 5, University of Illinois,
More informationSEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERS
International Journal of Civil Engineering and Technology (IJCIET) Volume 8, Issue, February 17, pp. 7 88 Article ID: IJCIET_8 8 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=8&itype=
More informationCOMPARISON BETWEEN TWO OPTIMIZATION PROCEDURES FOR DAMPER LOCATION IN STEEL FRAME STRUCTURES
COMPARISON BETWEEN TWO OPTIMIZATION PROCEDURES FOR DAMPER LOCATION IN STEEL FRAME STRUCTURES Aleksandra Bogdanovic, Zoran T. Rakicevic and Dejan Filipovski ABSTRACT The passive structural control of seismic
More informationVibration Control of Framed Structure Using Tuned Mass Damper
217 IJEDR Volume 5, Issue 3 ISSN: 2321-9939 Vibration Control of Framed Structure Using Tuned Mass Damper Saurabh Chalke 1, Prof P.V. Muley 2 1 PG Student, 2 Assistant Professor 1 Department of Civil Engineering,
More informationOptimum frictional elements in sliding isolation systems
Optimum frictional elements in sliding isolation systems R.S. Jangid Department of Civil Engineering, Indian Institute of Technology, Bombay, Powai, Mumbai 400 076, India Abstract The optimum friction
More informationApplication of Friction Pendulum Damper in Braced Frames and Its Effects on Structural Response
Application of Friction Pendulum Damper in Braced Frames and Its Effects on Structural Response S. M. Zahrai, M. S. Bozorgvar, and M. H. Bozorgvar Abstract In this paper Friction Pendulum Damper (FPD),
More informationEffects of opening in shear walls of 30- storey building
44 JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (2015) 44 55 Research Paper Effects of opening in shear walls of 30- storey building Ruchi Sharma a, Jignesh A. Amin b, * a Gujarat Water supply and
More informationSIGNIFICANCE OF ACCELERATION IN THE DESIGN OF DAMPERS FOR LIFELINE BUILDINGS IN SEISMIC GROUND MOTIONS
SIGNIFICANCE OF ACCELERATION IN THE DESIGN OF DAMPERS FOR LIFELINE BUILDINGS IN SEISMIC GROUND MOTIONS ABSTRACT: Arun M Puthanpurayil 1 and Dr. Paul Reynolds 2 1 Structural Engineer, Gifford, UK 2 Senior
More informationVALLIAMMAI ENGINEERING COLLEGE DEPARTMENT OF CIVIL ENGINEERING SUBJECT CODE: CE6701 SUBJECT NAME: STRUCTURAL DYNAMICS AND EARTHQUAKE ENGINEERING YEAR : IV SEM : VII QUESTION BANK (As per Anna University
More informationEstimating the overall damping ratio in structures with brace damper systems
Estimating the overall damping ratio in structures with brace damper systems J. M. Londoño, D.J. Wagg & S.A. Neild Department of Mechanical Engineering. University of Bristol. Bristol, United Kingdom.
More informationCOMPARITIVE STUDY OF BASE ISOLATORS AND VISCOUS FLUID DAMPERS ON SEISMIC RESPONSE OF RC STRUCTURES
International Journal of Civil Engineering and Technology (IJCIET) Volume 9, Issue 8, August 2018, pp. 798 806, Article ID: IJCIET_09_08_081 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=9&itype=8
More informationSimplified Finite Element Modelling of Multi-storey Buildings: The Use of Equivalent Cubes
Electronic Journal of Structural Engineering (8) 28 Simplified Finite Element ling of Multi-storey Buildings: The Use of Equivalent Cubes B. Li, C. F. Duffield & G. L. Hutchinson University of Melbourne,
More informationEVALUATION OF SEISMIC BEHAVIOR OF IRREGULAR STEEL STRUCTURES IN PLAN WITH BRB AND EBF BRACES UNDER NEAR-FAULT EARTHQUAKE
IJBPAS, January, 2015, 5(1), Special Issue: 572-581 ISSN: 2277 4998 EVALUATION OF SEISMIC BEHAVIOR OF IRREGULAR STEEL STRUCTURES IN PLAN WITH BRB AND EBF BRACES UNDER NEAR-FAULT EARTHQUAKE HOSSEIN NASERI
More informationChoice of in-structure Damping Model: Do we have an answer? Answer?
Choice of in-structure Damping Model: Do we have an answer? Answer? A. M. Puthanpurayil, R. P. Dhakal & A. J. Carr Department of Civil and Natural Resources Engineering, University of Canterbury, Christchurch,
More informationInvestigation of PTMD System Affected by Parkfield Near-Field Earthquake
; ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education Investigation of PTMD System Affected by Parkfield Near-Field Earthquake Ali Vatanshenas 1 1 Earthquake Engineering
More informationKiran K. Shetty & Krishnamoorthy Department of Civil Engineering, Manipal Institute of Technology, Manipal , Karnataka, India
Electronic Journal of Structural Engineering 12(1) 212 Response of space frame structure resting on non-linear rubber base isolation system Kiran K. Shetty & Krishnamoorthy Department of Civil Engineering,
More informationSTRUCTURAL CHALLENGES OF POWER PLANTS IN HIGH SEISMIC AREAS
STRUCTURAL CHALLENGES OF POWER PLANTS IN HIGH SEISMIC AREAS Peter NAWROTZKI 1 and Daniel SIEPE 2 ABSTRACT Power plant buildings and machines can be protected against seismic demands utilizing proven 3-
More informationInternational Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN
International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 189 VIBRATION CONTROL OF TENSION LEG PLATFORMS USING MASS DAMPERS UNDER RANDOM WAVES Fayiz C M 1, Dr. Jayalekshmi
More informationIMPROVING SEISMIC PERFORMANCE: ADD STIFFNESS OR DAMPING? Trevor E. Kelly 1
24 IMPROVING SEISMIC PERFORMANCE: ADD STIFFNESS OR DAMPING? Trevor E. Kelly 1 This paper was presented at the 2007 NZSEE Annual Conference in Palmerston North. ABSTRACT Structural engineers typically improve
More informationRISK-BASED DECISION ANALYSIS FOR BUILDING SERVICEABILITY
8 th ASCE Specialty Conference on Probabilistic Mechanics and Structural Reliability PMC2000-237 RISK-BASED DECISION ANALYSIS FOR BUILDING SERVICEABILITY S. K. Yalla, Student Member ASCE, A. Kareem, M.
More informationEFFICIENCY OF USING VISCOUS DAMPERS FOR MULTI-STOREY STEEL STRUCTURES SUBJECTED TO SEISMIC ACTIONS
11 th International Conference on Vibration Problems Z. Dimitrovová et al. (eds.) Lisbon, Portugal, 9-12 September 213 EFFICIENCY OF USING VISCOUS DAMPERS FOR MULTI-STOREY STEEL STRUCTURES SUBJECTED TO
More informationIntegrated Optimal Life Cycle Design of Super Tall Buildings with Viscous Dampers
11 th World Congress on Structural and Multidisciplinary Optimisation 07 th -12 th, June 2015, Sydney Australia Integrated Optimal Life Cycle Design of Super Tall Buildings with Viscous Dampers Xin Zhao
More informationCONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT
17th U.S.-Japan-New Zealand Workshop on the Improvement of Structural Engineering and Resilience CONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT N.
More informationExperimental Study on the Outrigger Damping System for High-Rise Building
Experimental Study on the Outrigger Damping System for High-Rise Building P. Tan, C.J. Fang, W.R. Tu & F.L. Zhou Guangzhou University, China Y. Wang & M. Jiang Ove Arup & Partners Ltd Shenzhen Branch,
More informationDUCTILITY SPECTRUM METHOD FOR DESIGN AND VERIFICATION OF STRUCTURES: SINGLE-DEGREE-OF-FREEDOM BILINEAR SYSTEMS
DUCTILITY SPECTRUM METHOD FOR DESIGN AND VERIFICATION OF STRUCTURES: SINGLE-DEGREE-OF-FREEDOM BILINEAR SYSTEMS Benazouz CHIKH 1, Moussa LEBLOUBA, Youcef MEHANI 3, Abderrahmane KIBBOUA 4, Ali ZERZOUR 5
More informationA study of the application of the pendulum tuned mass dampers in building floor vibration controls
A study of the application of the pendulum tuned mass dampers in building floor vibration controls M. Setareh 1, J. K. Ritchey & T. M. Murray 1 Department of Architecture, Virginia Polytechnic Institute
More informationcompares protection each soil and seismic seismic input. Keywords: Earthquake control require of the dissipate elastic energy. the restored comparing
A Parametric Study Involving Passive and Semi-active Control Schemes for Earthquake Protection of Buildings F. Ferreira, C. Moutinho, E. Caetano & A.. Cunha ViBest, Faculty of Engineering, University of
More informationSEISMIC RESPONSE OF BUILDING STRUCTURES WITH PASSIVE FLUID DAMPERS
ICAMS 2014 5 th International Conference on Advanced Materials and Systems SEISMIC RESPONSE OF BUILDING STRUCTURES WITH PASSIVE FLUID DAMPERS CRISTIAN PASTIA, SEPTIMIU-GEORGE LUCA, FIDELIU PAULET- CRAINICEANU,
More informationSEISMIC RESPONSE CONTROL OF ASYMMETRIC BUILDING USING VISCO-ELASTIC DAMPER
International INTERNATIONAL Journal of Civil Engineering JOURNAL and Technology OF CIVIL (IJCIET), ENGINEERING ISSN 0976 6308 AND (Print), TECHNOLOGY (IJCIET) ISSN 0976 6308 (Print) ISSN 0976 6316(Online)
More informationResponse Mitigation of Offshore Triceratops
Response Mitigation of Offshore Triceratops Induekha P 1, Dr. Jayalekshmi R 2 1PG Student, Department of Civil Engineering, NSS College of Engineering, Palakkad 2Professor, Department of Civil Engineering,
More informationStudying the effects of earthquakes near and far fault region on seismic behavior of dual frame equipped with viscous damper
Studying the effects of earthquakes near and far fault region on seismic behavior of dual frame equipped with viscous Hamid Reza Ashrafi 1, Amir Mohammad Amiri 2, Soroush Dadgar 3, Peyman Beiranvand 4
More informationInfluence of Passive Isolator Parameters on Seismic Response Control of Multi-Span Bridges
International Journal of Scientific and Research Publications, Volume 5, Issue 4, April 2015 1 Influence of Passive Isolator Parameters on Seismic Response of Multi-Span Bridges B.Neethu *, Diptesh Das
More information