Residential Pricing Guide

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Residential Pricing Guide"

Transcription

1 Guide

2

3 TABLE OF CONTENTS Panels 5V Crimp Slimline 2 4 Accessories Flat Sheets Coils V-Groove Soffit Ridge Caps Roof Jacks Touch-up Paint Insulation Slimline Rib Cover Closure Strips Tube Sealant Trim All Trim 11 1

4 PANELS 5V Crimp NUMBER OF SQUARE FEET PER PANEL 0" 1" 2" 3" 4" 5" 6" 7" 8" 9" 10" 11" 1 FT. 2 FT. 3 FT. 4 FT. 5 FT FT. 7 FT. 8 FT. 9 FT. 10 FT FT. 12 FT. 13 FT. 14 FT. 15 FT FT. 17 FT. 18 FT. 19 FT. 20 FT FT. 22 FT. 23 FT. 24 FT. 25 FT FT. 27 FT. 28 FT. FT. 30 FT FT. 32 FT. 33 FT. 34 FT. 35 FT FT. 37 FT. 38 FT. 39 FT. 40 FT

5 PANELS 5V Crimp PRICED PER SQUARE PANEL COVERAGE YIELD (PSI) WEIGHT PER SQ. FINISH PRICE 24" 80,000 71# Galvalume Plus 24" 24" 80,000 80,000 82# 82# Galvalume Plus Signature 200 * Please Inquire * See Commercial/Industrial Color Chart for available colors The Galvalume Plus coating is subject to variances in spangle from coil to coil which may result in noticeable shade variation in installed panels. The Galvalume Plus coating is also subject to differential weathering after panel installation. Panels may appear to be different shades due to this weathering characteristic. If a consistent appearance is required, MBCI recommends that pre-painted panels be used in lieu of Galvalume Plus. Shade variation in panels manufactured from Galvalume Plus coated material do not diminish the structural integrity of the product. These shade variations should be anticipated and are not a cause for rejection. Consult the MBCI 5V CRIMP DESIGN & INSTALLATION MANUAL for proper product application, design details and other product information. Panel Pricing: 1. All 5V Crimp panel pricing is based on a " sheet width (see chart on opposite page). 2. Minimum quantities may be required for certain panel gauges and/or colors. Please Inquire. 3. Add $1.05 per sheet for lengths 4'-0" and under. Packaging Cost: Maximum 3000 pounds or 75 panels per bundle. Block and band only...$10.00 Block and band, waterproof paper wrap...$1.40/linear foot Block and band, waster sheet top only...$1.60/linear foot Block and band, waster sheet top and bottom...$2.80/linear foot LTL Package - block and band, waster sheet top and bottom, angle board sides and ends...$3.50/linear foot Export Package - block and band, waster sheet top and bottom, steel and wood boxed...special order only Delivery: 1. Stocked colors (see Commercial/Industrial Color Chart)...Approximately 5 working days Notes: 1. For panel lengths over 25'-0"...Please inquire 2. Heavier gauges may minimize oil canning. IMPORTANT NOTICE TO INSTALLER/CUSTOMER: Material should be inspected carefully prior to installation for defects including excessive oil canning. Installation of material constitutes acceptance. 3

6 PANELS Slimline Minor Ribs w/striations Striations NUMBER OF SQUARE FEET PER PANEL 0" 1" 2" 3" 4" 5" 6" 7" 8" 9" 10" 11" 1 FT. 2 FT. 3 FT. 4 FT. 5 FT FT. 7 FT. 8 FT. 9 FT. 10 FT FT. 12 FT. 13 FT. 14 FT. 15 FT FT. 17 FT. 18 FT. 19 FT. 20 FT FT. 22 FT. 23 FT. 24 FT. 25 FT FT. 27 FT. 28 FT. FT. 30 FT FT. 32 FT. 33 FT. 34 FT. 35 FT FT. 37 FT. 38 FT. 39 FT. 40 FT

7 PANELS Slimline Minor Ribs w/striations Striations PRICED PER SQUARE PANEL COVERAGE YIELD (PSI) WEIGHT PER SQ. FINISH PRICE 16" 16" 50,000 50,000 76# 76# Galvalume Plus Signature 200 * 16" 16" 50,000 50,000 99# 99# Galvalume Plus Signature 200 * * See Residential Color Chart for available colors. The Galvalume Plus coating is subject to variances in spangle from coil to coil which may result in noticeable shade variation in installed panels. The Galvalume Plus coating is also subject to differential weathering after panel installation. Panels may appear to be different shades due to this weathering characteristic. If a consistent appearance is required, MBCI recommends that pre-painted panels be used in lieu of Galvalume Plus. Shade variation in panels manufactured from Galvalume Plus coated material do not diminish the structural integrity of the product. These shade variations should be anticipated and are not a cause for rejection. Panel Pricing: All pricing is based on net coverage (see chart on opposite page). Minimum quantities may be required for certain panel gauges and/or colors. Please Inquire. Add $1.05 for lengths 4'-0" and under. Panels must be specified as: "striated" or "striated with minor ribs". Packaging Costs: 1. Standard packaging: Strippable film on painted panel ribs, cardboard box, wood saddles and trusses as required: Add $0.10 per square foot - $60.00 minimum. Galvalume Plus panels will have micro foam interleaf: Add $0.10 per square feet - $60.00 minimum. 2. LTL shipments require plywood crating. 3. Plywood crating: Add $15.50/lf of bundle - $ minimum. 4. Special packaging: Please inquire. Delivery: 1. gauge Stocked colors (see Slimline Panel Residential Color Chart)...Approximately 15 working days 2. gauge Stocked colors (see Slimline Panel Residential Color Chart)...Approximately 15 working days 3. Other gauges, colors and metals...please inquire Notes: If non-striated or without minor ribs are required, customer must specify in writing on order. Slimline panels cannot be endlapped. For panel lengths over 40'-0"...Please inquire Heavier gauges, striations or minor ribs may minimize oil canning. IMPORTANT NOTICE TO INSTALLER/CUSTOMER: Material should be inspected carefully prior to installation for defects including excessive oil canning. Installation of material constitutes acceptance. 5

8 ACCESSORIES Flat Sheets Notes: 1. Add $42.00 for flat sheet wood skid/maximum 100 flat sheets or 3000# per skid. Maximum 14'-0" length. 2. Add $60.00 for LTL crating/maximum 100 flat sheets or 3000# per skid. Maximum 14'-0" length. 3. Strippable film available for flat sheets upon request. Add $0.10 per square foot. 4. Minimum length 5'-0", maximum length 14'-0". Flat sheet lengths over 14'-0" require special skid. Please inquire. 5. All material is Grade D. PRICED PER LINEAR FOOT WIDTH FINISH WEIGHT PER LF PRICE 441/2" 407/8" Galvalume Plus Signature 200 * 3.00# 2.00# * See Residential Color Chart for available colors. The Galvalume Plus coating is subject to variances in spangle from coil to coil which may result in noticeable shade variation in installed panels. The Galvalume Plus coating is also subject to differential weathering after panel installation. Panels may appear to be different shades due to this weathering characteristic. If a consistent appearance is required, MBCI recommends that pre-painted panels be used in lieu of Galvalume Plus. Shade variation in panels manufactured from Galvalume Plus coated material do not diminish the structural integrity of the product. These shade variations should be anticipated and are not a cause for rejection. Coils Notes: Add $ set-up charge for coil. (Minimum 300 L.F.) Add $42.00 per coil for wood skid. All coils are subject to ± 15% of quantity ordered. The camber tolerance for coils is one inch in any 20 feet. Slitting available upon request - $0.10 per LF - $ minimum charge. 6. All material is Grade D or E. WIDTH 441/ 2" 407/8" PRICED PER CLF COIL FINISH Plus Galvalume Signature 200 * WEIGHT PER LF PRICE 3.00# 2.00# * See Residential Color Chart for available colors. The Galvalume Plus coating is subject to variances in spangle from coil to coil which may result in noticeable shade variation in installed panels. The Galvalume Plus coating is also subject to differential weathering after panel installation. Panels may appear to be different shades due to this weathering characteristic. If a consistent appearance is required, MBCI recommends that pre-painted panels be used in lieu of Galvalume Plus. Shade variation in panels manufactured from Galvalume Plus coated material do not diminish the structural integrity of the product. These shade variations should be anticipated and are not a cause for rejection. 6

9 ACCESSORIES V-Groove Soffit Notes: Requires 15 day lead time - Not available in gauge. Field cut to required length - 3'-0" maximum. See Residential Color Chart for available colors. LG-140 MATERIAL Gauge Steel 12'-6" 133/4" 8.83# N/A Vented V-Groove Soffit Notes: Requires 15 day lead time - Not available in gauge. Field cut to required length - 3'-0" maximum. See Residential Color Chart for available colors. LG-142 MATERIAL Gauge Steel 12'-6" 133/4" 8.83# N/A Ridge Cap - 5V Crimp Notes: Specify roof slope. See Commercial/Industrial Color Chart for available colors. HW-1110 HW-1110 ROOF SLOPE 3:12-9:12 3:12-9:12 1'-2" 1'-2" 1.80# 2.15# N/A 7

10 ACCESSORIES Rubber Roof Jack HW-1000 HW-1001 HW-1002 HW-1003 HW-1004 TEMPERATURE RANGE -65 F to +212 F -65 F to +212 F -65 F to +212 F -65 F to +212 F -65 F to +212 F PIPE SIZE 1/ 1 4" - 1 / 2" 1 1 /2" - 4" 41/4" - 6" 6" - 11" 7" - 13" BASE DIM. PRICE 4 1/ 2" 8" 11" 14" 17".17#.50#.95# 1.55# 2.56# 8" 11" 17" 25".50#.95# 2.56# 3.86# HIGH TEMPERATURE HW-1046 HW-1047 HW-1048 HW F to +437 F -100 F to +437 F -100 F to +437 F -100 F to +437 F 1/ 4" - 4" 41/4" - 7" 7" - 13" 10" - 18" Retrofit Rubber Roof Jack HW-1005 HW-1006 HW-1007 TEMPERATURE RANGE PIPE SIZE BASE DIM. PRICE -65 F to +212 F -65 F to +212 F -65 F to +212 F 1/ " - 4" 4 4" - 91/4" 91/4" - 161/4" 83/16" 141/4" 211/2".74# 2.20# 3.78# 83/16" 141/4" 211/2".74# 2.20# 3.78# HIGH TEMPERATURE HW-1060 HW-1061 HW F to +437 F -100 F to +437 F -100 F to +437 F 1/ - 4" 4" - 91/4" 91/4" - 161/4" 2" 8

11 ACCESSORIES Touch-Up Paint HW-304 FINISH SIZE COLOR PRICE Signature ounce See Residential Color Chart.50# Reflective Insulation Notes: PSR-VR with VersiTab is 1/4" fiberglass with a white polypropylene scrim reinforced vapor retarder on one side and a foil film on the other side. RFSK with VersiTab 1/4" fiberglass with a silver (aluminum) scrim reinforced vapor retarder on one side and a foil film on the other side. VersiTab has a 2" tab on one side and a 4" tab on the other side of the roll to allow the insulation side laps to be folded and stapled or overlapped and taped. HW-3744 HW-3745 HW-3748 HW-3749 PRICED PER ROLL TYPE WIDTH ROLL WEIGHT PRICE PSK-VR w/ VersiTab RFSK w/ VersiTab PSK-VR w/ VersiTab RFSK w/ VersiTab 4'-0" 4'-0" 6'-0" 6'-0" 125'-0" 125'-0" 125'-0" 125'-0" 31.00# 31.00# 46.00# 46.00# Scrimless Aluminum Tape WIDTH ROLL WEIGHT PRICE 3" 150'-0" 1.50# HW-514 Slimline Rib Cover Notes: Use with Slimline panels at roof to fascia transitions. All standard colors - See Residential Color Chart. CF-119 CF / 8" 4 1/ 8".12#.14# 9

12 ACCESSORIES Closure Strip - 5V Crimp HW-450 HW-452 TYPE ADHESIVE? SIZE PRICE Inside Outside No Yes 1" x 24" 1" x 24".04#.05# Tube Sealant 25' per tube at 1/4" bead. HW-548 HW-550 HW-540 HW-541 HW-542 HW-544 HW-549 PRICED PER TUBE TYPE COLOR TUBE SIZE TUBE WEIGHT PRICE Acrylic Acrylic Urethane Urethane Urethane Urethane Non-Skinning Butyl White Gray White Gray Bronze Almond White 11 ounce 11 ounce 11 ounce 11 ounce 11 ounce 11 ounce 10 ounce.75#.75#.85#.85#.85#.85# 1.00# 10

13 Ridge/Hip Flash Specify roof slope or angle indicated on drawing. Specify use for Ridge or Hip AG-202 AG-202 AG-203 AG " 13" 13" 13" 6.44# 8.37# 12.88# 16.74# Vented Ridge Flash Specify roof slope or angle indicated on drawing. AG-207 AG-207 AG-208 AG /2" 211/2" 211/2" 211/2" 10.62# 13.84# 21.24# 27.68# 11

14 Peak Cap Specify roof slope or angle indicated on drawing. AG-233 AG-233 AG-234 AG /8" 115/8" 115/8" 115/8" 5.76# 7.48# 11.52# 14.96# Standard Valley Specify roof slope or angle indicated on drawing. AG-237 AG-237 AG-238 AG-238 DIM "A" 9 1/ 4" 911/16" 9 1/ 4" 911/16" 201/2" 213/8" 201/2" 213/8" 10.88# 14.16# 21.76# 28.32# Extended Valley Specify roof slope or angle indicated on drawing. AG-239 AG-239 AG-240 AG-240 DIM "A" 197/16" 203/8" 197/16" 203/8" 14'-0" 14'-0" 407/8" 423/4" 407/8" 423/4" 21.73# 28.# 28.71# 38.82# 12

15 Box Gutter Notes: Specify roof slope or angle indicated on drawing. Snow gutter available - Please inquire. 173/8" 173/8" 173/8" 173/8" 8.22# 10.71# 16.44# 21.42# AG-242 AG-242 AG-243 AG-243 5K Gutter Requires 15 day lead time. LG '-0" 123/8" 9.86# N/A Residential Gutter Specify roof slope or angle indicated on drawing. FL /16" 6.41# 13

16 Gutter Ends Notes: Specify left or right. LG-167A and LG-167B require 15 day lead time. Box 5K TYPE AG-245 AG-245 FL-1001 FL-1001 Box Box Box Box.15#.19#.08#.10# LG-167A LG-167B 5K (Left) 5K (Right).10#.10# N/A N/A Gutter Strap Use with AG-242 or AG-243 Box Gutter only. AG-244 AG-244 8" 8" 2" 2".08#.09# Gutter Apron LG-149 LG-149 5" 5" 2.73# 3.40# 14

17 3" Oval Outlet Requires 15 day lead time. GALVANIZED.05# HW K 3" Downspout Requires 15 day lead time. LG '-0" 133/4" 5.46# N/A 5K Elbows Requires 15 day lead time. LG-151 LG-151A TYPE A B.50#.50# N/A N/A 15

18 Box Downspout - Straight LG-155 FL-31 LG-155A FL-31B 14'-0" 14'-0" 163/4" 167/8" 163/4" 167/8" 9.15# 11.12# 12.19# 15.32# Box Downspout With 45 Elbow LG-157 FL-31A LG-157A FL-31E 14'-0" 14'-0" 163/4" 167/8" 163/4" 167/8" 9.15# 11.12# 12.19# 15.32# Box Downspout Elbow LG-160 FL-32 LG-160A FL-33 ELBOW ANGLE " 7" 7" 7" 167/8" 167/8" 167/8" 167/8" 1.02# 1.32#.99# 1.28# 16

19 Eave Trim Specify roof slope or angle indicated on drawing. AG-246 AG-246 AG-247 AG / 8" 7 5/ 8" 7 5/ 8" 7 5/ 8" 3.48# 4.51# 6.96# 9.02# Fascia Angle AG-252 AG-252 AG-253 AG-253 8" 8" 8" 8" 3.98# 5.16# 7.96# 10.32# Soffit Angle AG-258 AG / 2" 2 1/ 2" 1.24# 1.62# 17

20 Sidewall Flashing LG-109 LG / 4" 8 1/ 4" 4.50# 5.62# Endwall Flashing Specify roof slope or angle indicated on drawing. LG / 4" 5.32# Concealed Rake CF-301 CF-301A DIM "A" 3" 6" 8 1/ 8" 111/8" 4.44# 6.07# 18

21 5V Crimp Rake Trim DIM "A" ROOF SLOPE WEIGHT EACH FL-1020 FL-1020 FL-1021 FL-1021 FL-1022 FL-1022 FL-1023 FL-1023 FL-1024 FL /16" 215/16" 213/16" 213/16" 211/16" 211/16" /16" /16" 27/16" 27/16" 3-4:12 3-4:12 5-6:12 5-6:12 7:12 7:12 8-9:12 8-9:12 10:12 10:12 87/16" 87/16" 85/16" 85/16" 83/16" 83/16" 81/16" 81/16" 715/16" 715/16" 4.31# 5.57# 4.24# 5.49# 4.18# 5.40# 4.12# 5.32# 4.05# 5.24# Slimline Rake Trim Use with FL-1050 Eave with Drip Edge DIM "A" ROOF SLOPE WEIGHT EACH FL-1030 FL-1030 FL-1031 FL-1031 FL-1032 FL-1032 FL-1033 FL-1033 FL-1034 FL /16" 37/16" 35/16" 35/16" 33/16" 33/16" 31/16" 31/16" 215/16" 215/16" 3-4:12 3-4:12 5-6:12 5-6:12 7:12 7:12 8-9:12 8-9:12 10:12 10:12 813/16" 813/16" 811/16" 811/16" 89/16" 89/16" 87/16" 87/16" 85/16" 85/16" 4.50# 5.82# 4.44# 5.73# 4.37# 5.65# 4.31# 5.57# 4.24# 5.49# 19

22 Slimline Rake Trim AG-454 AG / 8" 8 5/ 8" 4.31# 8.62" 5V Crimp Parapet Rake Trim FL-1060 FL /8" 107/8" 5.55# 7.18# Rake Transition AG-1 AG-1 AG-2 AG-2 10" 10" 10" 10" 5.27# 6.45# 9.90# 12.90# 20

23 High Side Transition Specify roof slope or angle indicated on drawing. AG-3 AG-3 AG-4 AG-4 8 1/ 2" 8 1/ 2" 8 1/ 2" 8 1/ 2" 4.21# 5.61# 8.42# 10.96# Continuous Cleat 24 gauge material - Assorted colors only. FL-338 ASSORTED COLORS 3" # Offset Cleat 24 gauge material - Assorted colors only. FL-337 ASSORTED COLORS 3 1/ 2" # 21

24 Fascia/Soffit Trim 85/16" 85/16" 85/16" 85/16" 4.15# 5.37# 8.30# 10.74# AG-458 AG-458 AG-460 AG-460 Fascia Trim 7 3/ 8" 7 3/ 8" 7 3/ 8" 7 3/ 8" 3.61# 4.69# 7.22# 9.38# AG-462 AG-462 AG-464 AG-464 Panel Cap Use with Slimline panels only. AG-450 AG /16" 59/16" 2.90# 5.80# 22

25 Slimline Z Closure AG-470 DIM "A" 1" 3" 1.65# 5V Crimp Z Closure AG / 4" 1.78# Eave Trim with Drip Edge Specify roof slope or angle indicated on drawing. AG-279 AG / 8" 9 5/ 8" 4.77# 6.18# 23

26 Metal Drip Edge Specify roof slope or angle indicated on drawing. AG-283 AG-283 4" 4" 2.02# 2.64# 24

27 Trim Pricing: 1. All trim is and gauge unless noted. Please note that gauge colors and gauge colors are not the same. See Residential Color Chart for available colors. 2. When ordering standard trim in custom lengths, use price per linear foot for standard trim plus a 10% surcharge. 3. Prices do not include standard packaging. 4. Strippable film available for trim upon request. Add $0.10 per square foot. Packaging Cost: 1. Trim with girth greater than 15"...20 pieces/carton 2. Trim with girth less than 15"...50 pieces/carton 3. Downspouts...12/carton 4. Standard Packaging: Cardboard with metal bands...$3.44/linear foot 5. LTL Packaging: Cardboard with wood blocks and metal bands...$4.63/linear foot 6. Plywood crating...$9.50/linear foot 7. Paper wrap only (For customer pick-up only)...$ Minimum packaging charge...$ Minimum crating charge...$ Special Packaging...Please Inquire Delivery: 1. gauge and gauge stocked colors (see Residential Color Chart)...Approximately 10 Working Days 2. Other gauges, colors and metals...please Inquire Price your own special trim: Calculate the number of square feet of material (girth x length). Multiply number of square feet by the appropriate square foot price (see chart below). Add $1.60 for each break and $3.20 for each hem. Add appropriate packaging costs. Specify the side with the color or finished coat. Send sketch of the special flashing to MBCI with order. If more than one special trim is required, number them SF1, SF2, SF3, etc. PRICED PER SQUARE FOOT 25

28 Contact Us: Houston, TX: Adel, GA: Atlanta, GA: Atwater, CA: Ennis, TX: Indianapolis, IN: Lubbock, TN: Memphis, TN: Oklahoma City, OK: Phoenix, AZ: Copyright NCI Group, Inc All rights reserved. Rome, NY: Salt Lake City, UT: San Antonio, TX:

Central Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼

Central Texas Metal Roofing Supply Co., Inc 36 NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼ 36" 1 2 " 6" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 26 26 26 24 24 24 24 TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD TEXAS RIB CHANNEL GUARD CHANNEL GUARD CHANNEL GUARD GALVALUME

More information

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH 1 2 " 1 24" GAUGE PANEL FINISH NET COVERAGE SHEET WIDTH WEIGHT PER SQ. 26 5 Vee GALVALUME 24 26 3/8 95.00 PRICE PER SQ. PRICE PER LINEAR FOOT PANEL PRICING: 1. Price per Square is based on 26 3/8 sheet

More information

PBR & PBU Panels. Technical/Installation Information

PBR & PBU Panels. Technical/Installation Information PBR & PBU Panels Technical/Installation Information TABLE OF CONTENTS A. PBR Panel 1. General Description..................................................................... 2 2. Architect/Engineer Information............................................................

More information

PBR & PBU PANELS. Technical/Installation Information

PBR & PBU PANELS. Technical/Installation Information PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,

More information

TRIAD CORRUGATED METAL, INC.

TRIAD CORRUGATED METAL, INC. TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial

More information

S BI COM P ON E NT CA T ALOG

S BI COM P ON E NT CA T ALOG SBI METAL BUILDINGS & COMPONENTS S BI COM P ON E NT CA T ALOG Date: 03 / 16 / 2017 COMMERCIAL PRODUCTS Commercial Panels and Trim Cee, Zee, Eave Struts, Angle, Channel, and Clips Accessories FT 0 1 2 3

More information

Western States 7/8 Corrugated

Western States 7/8 Corrugated Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key

More information

1.5 mechanical lock ml 150

1.5 mechanical lock ml 150 1.5 mechanical lock ml 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings Max 16 Steel.0225 to.0336 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX554 The Mechanical

More information

The Experts in Retrofit Design. Retrofit Solutions. Retro-R SSR NuRoof NuWall

The Experts in Retrofit Design. Retrofit Solutions. Retro-R SSR NuRoof NuWall The Experts in Retrofit Design Retrofit Solutions Retro-R SSR NuRoof NuWall Retrofit Solutions by MBCI MBCI has experience in retrofitting existing buildings proven with millions of square feet of successfully

More information

SECTION METAL ROOF PANELS

SECTION METAL ROOF PANELS SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof

More information

PIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components

PIPE. Central Texas Largest Distributor.  Structural Steel, Pipe and Metal Building Components Central Texas Largest Distributor Structural Steel, Pipe and Metal Building Components PIPE Waco Location P.O. Box 154485 913 South Loop Dr. Waco Texas 76705 Local - 254-754-2611 Bryan Location 9401 E.

More information

Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 5V Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES ½" 24" COVERAGE Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_5V_180201 The men

More information

238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM #

238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM # 238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM # DESCRIPTION SELLING PRICE UOM 238T 238T Seam Cap 24

More information

5V CRIMP. Technical/Installation Information

5V CRIMP. Technical/Installation Information 5V CRIMP Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL OCMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE

More information

SECTION PRE-ENGINEERED WOOD POST FRAME BUILDING SYSTEM. B. Products Supplied But Not Installed Under This Section:

SECTION PRE-ENGINEERED WOOD POST FRAME BUILDING SYSTEM. B. Products Supplied But Not Installed Under This Section: SECTION 13125 FRAME BUILDING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Primary and secondary wood structural framing systems, roofing and wall covering systems, roof and wall insulation,

More information

1 1/2" SSR. FABRAL The pursuit of excellence since 1967

1 1/2 SSR. FABRAL The pursuit of excellence since 1967 1 1/2" SSR Detail Manual and Estimate Guide 16" 1 1 2" PROPER STORAGE When moisture remains in contact with Galvanized panels in the absence of freely circulating air, white, black or dark gray corrosion

More information

Agricultural METAL ROOFING

Agricultural METAL ROOFING Agricultural METAL ROOFING Building Relationships Since 1908 American Building Components started its business by serving the agricultural consumer. Since 1908, we have worked side by side with our customers

More information

Central Seam Plus. Central-Loc

Central Seam Plus. Central-Loc Central Seam Plus Central-Loc Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 3" 3" " or 18" COVERAGE " or 18" COVERAGE Central Seam Plus Field seamed Central-Loc Snaps together

More information

Stile. Spanish Tile Installation Guide

Stile. Spanish Tile Installation Guide Stile Spanish Tile Installation Guide IMPORTANT INFORMATION THE APPLICATION AND DETAIL DRAWINGS IN THIS MANUAL ARE STRICTLY FOR ILLUSTRATION PURPOSES AND MAY NOT BE APPLICABLE TO ALL BUILDING DESIGNS OR

More information

NuRoof Retrofit Systems. Technical/Installation Information

NuRoof Retrofit Systems. Technical/Installation Information Retrofit Systems Technical/Installation Information INTRODUCTION If your roof is causing problems due to leaks, high maintenance costs and low energy efficiency, the MBCI NuRoof Retrofit System is the

More information

RIB PANEL INSTALLATION

RIB PANEL INSTALLATION GOLDIN METALS, INC. www.goldinmetals.com 12440 SEAWAY ROAD Mailing Address: 14231 SEAWAY ROAD, SUITE 7000 GULFPORT, MS 39503 (228) 896-6216, Ext. 230 FAX (228) 896-4873 4400 PETERS ROAD P.O. BOX 700 HARVEY,

More information

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

Prior to ordering and installing materials, all dimensions should be verified by field measurements. Important Information The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects

More information

ML-150. w w w. s a q u l i t y m e ta l s. c o m. san antonio branch 210 W. Peden San Antonio TX P. (210) F.

ML-150. w w w. s a q u l i t y m e ta l s. c o m. san antonio branch 210 W. Peden San Antonio TX P. (210) F. ML-150 san antonio branch 210 W. Peden San Antonio TX 78204 P. (210) 227-7276 F. (210) 227-0329 MCALLEN branch 2221 Austin Ave McAllen TX 78501 P. (956) 627-2966 F. (956) 627-0918 w w w. s a q u l i t

More information

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information Table of ontents Product Page No. Product Page No. Panel Information Profile...PST-2 Panel Overview...PST-2 Flashing Profiles Eave...PST- Extended Eave...PST- leat...pst- Stile Starter...PST- Box Gutter...PST-

More information

ShadowRib Metal Wall Panel INSTALLATION GUIDE

ShadowRib Metal Wall Panel INSTALLATION GUIDE Metal Wall Panel INSTALLATION GUIDE IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ROOFING SYSTEM. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

CATALOG STEEL BUILDING

CATALOG STEEL BUILDING CATALOG STEEL BUILDING 2 Why Metal Depots 9 Carports 14 Windows TABLE OF CONTENTS 2 Build Your Dream 10 Light-Gauge Structural 14 Roll-Up Doors 3 Handyman Series 11 Light-Transmitting Panels 15 Sealants

More information

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5

More information

MBCI Weathertightness WARRANTIES

MBCI Weathertightness WARRANTIES MBCI Weathertightness WARRANTIES WEATHERTIGHTNESS WARRANTIES MBCI believes if the building owner has to file a claim against the roof manufacturer s Weathertightness Warranty, then someone has not done

More information

DETAIL MANUAL A COMPREHENSIVE GUIDE TO METAL ROOFING GULFLOKTM HIDDEN SCREW METAL ROOF SYSTEM

DETAIL MANUAL A COMPREHENSIVE GUIDE TO METAL ROOFING GULFLOKTM HIDDEN SCREW METAL ROOF SYSTEM DETAIL MANUAL A COMPREHENSIVE GUIDE TO METAL ROOFING GULFLOKTM HIDDEN SCREW METAL ROOF SYSTEM Gulf Coast Standing Seam Roofing Panels Since 2004, Gulf Coast Supply and Manufacturing has been happy to offer

More information

Retro-R DESIGN/INSTALLATION INFORMATION

Retro-R DESIGN/INSTALLATION INFORMATION Retro-R DESIGN/INSTALLATION INFORMATION IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM TO

More information

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation

More information

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax: Brava Spanish Tile Installation Manual Brava Roof Tile Phone: 319-338-5706 Fax: 319-343-1038 www.bravarooftile.com This document includes the recommended and suggested installation procedures for Brava

More information

CS-100 Guide Specifications

CS-100 Guide Specifications MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification

More information

ALLMET CONTINENTAL INSTALLATION GUIDE

ALLMET CONTINENTAL INSTALLATION GUIDE ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental

More information

29 Gauge. Technical/Installation Information

29 Gauge. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE 29 GAUGE LOW PROFILE PANELS PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED

More information

INSTALLATION GUIDE.

INSTALLATION GUIDE. INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten

More information

ROOF ASSEMBLIES CHAPTER 9

ROOF ASSEMBLIES CHAPTER 9 CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION

More information

BattenLok HS. Technical/Installation Information

BattenLok HS. Technical/Installation Information BattenLok HS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ROOFING SYSTEM. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM

More information

TABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles

TABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles TABLE OF ONTENTS Product Page No. Product Page No. Panel Information Profi les...pim-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3

More information

Specifications for FL-100 Soffit Panel

Specifications for FL-100 Soffit Panel Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated

More information

Designer Series. Technical/Installation Information

Designer Series. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Designer Series WALL SYSTEM. MBCI MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE

More information

TREMLOCK SL INSTALLATION MANUAL

TREMLOCK SL INSTALLATION MANUAL TREMLOCK SL INSTALLATION MANUAL TREMLOCK SL TremLock SL i a concealed fatener architectural tanding eam roof panel. The TremLock SL panel are eaily intalled over decking, utilizing metal clip. TremLock

More information

Metal Roof Panels

Metal Roof Panels University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 074113 - Metal

More information

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS SECTION 07410 - PREFORMED ROOF AND WALL PANELS # Specifier: Notation (#) means that text following is a specifier s note or sample. PART 1 - GENERAL 1.01 Description # Specifier: Do not alter paragraph

More information

DAN S CUSTOM SHEETMETAL Manufacturer and Distributor

DAN S CUSTOM SHEETMETAL Manufacturer and Distributor About the Company DAN S CUSTOM SHEETMETAL Manufacturer and Distributor In 1993, DCSM was the first manufacture in the state of Florida to fabricate metal eave closure for tile. We have established a reputation

More information

Specifier Note: Revise paragraph below to suit project requirements. Add section numbers per CSI MasterFormat and specifier s practice.

Specifier Note: Revise paragraph below to suit project requirements. Add section numbers per CSI MasterFormat and specifier s practice. McElroy Metal, Inc. 1500 Hamilton Rd. Bossier City, LA 71111 Phone: (800) 562-3576 Phone: (318) 747-8097 Fax: (318) 747-8099 E-mail: info@mcelroymetal.com www.mcelroymetal.com This MANU-SPECª utilizes

More information

INSTALLATION MANUAL Heritage Series

INSTALLATION MANUAL Heritage Series INSTALLATION MANUAL Heritage Series STEEL ROOF PANELS HEAD OFFICE 1418 Michael St., Ottawa, ON K1B 3R2 WATS LINE: 1 800-267-0860 TEL.: 1 613-746-3206 FAX: 1 613-746-0445 Contents Page Introduction, Storage..

More information

1. Include similar Samples of trim and accessories involving color selection.

1. Include similar Samples of trim and accessories involving color selection. SECTION 074116- INSULATED METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

ROOF ASSEMBLIES CHAPTER 9

ROOF ASSEMBLIES CHAPTER 9 CHAPTER 9 ROOF ASSEMBLIES > SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Pursuant to ORS 215.730; if

More information

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate

More information

PRE-ENGINEERED METAL BUILDING SYSTEM

PRE-ENGINEERED METAL BUILDING SYSTEM PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,

More information

MS-100 MS-150. MS SERIES Flashing and Details Guide. MS150 Flashing and Details Guide. MS200 Flashings and Details Guide

MS-100 MS-150. MS SERIES Flashing and Details Guide. MS150 Flashing and Details Guide. MS200 Flashings and Details Guide Taylor Metal Products - Phone: 503-581-8338 or 800-574-1388 - Fax: 503-581-6877 - www.taylormetal.com MS200 Flashings and Details Guide MS150 MS SERIES MS-100 MS-150 MS-100 MECHANICALLY SEAMED The MS-100

More information

Central Snap. Condition Details C SNAPDETAILS

Central Snap. Condition Details C SNAPDETAILS Central Snap Condition Details D C SNAPDETAILS150612.2 The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing, Inc. is a 100% employee-owned

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal

More information

Central Snap. Product Guide. 16" or 18" COVERAGE 1¾" HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

Central Snap. Product Guide. 16 or 18 COVERAGE 1¾ HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES Central Snap Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 1¾" 16" or 18" COVERAGE Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_CENTRALSNAP_180201.1

More information

Drexel Metals Clips and Accessories

Drexel Metals Clips and Accessories Drexel Metals Clips and Accessories Your machine makes one component of the total metal roof system. Drexel Metals has invested millions of dollars to ensure our metal roof system meet the required building

More information

OREGON ROOF CONSULTING - ROOF INSPECTION FORM

OREGON ROOF CONSULTING - ROOF INSPECTION FORM Oregon CCB: 199121 PO Box 220190, Milwaukie, OR 97222 Washington License: OREGORC871MR OREGON ROOF CONSULTING - ROOF INSPECTION FORM General Roof Conditions: NA = Not Applicable Debris on Roof Physical

More information

LokSeam. Technical/Installation Information

LokSeam. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ROOFING SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE

More information

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)

More information

Preformed Metal Roof And Wall Systems

Preformed Metal Roof And Wall Systems 07 40 00/MBC BuyLine 3861 Preformed Metal Roof And Wall Systems OUR PANELS MAKE THE difference www.mbci.com MBCI has earned its reputation as one of the nation s leading suppliers of preformed metal for

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION SECTION 07320 TWO-PIECE TAPERED MISSION CLAY ROOFING TILE PART 1 GENERAL 1.01 SECTION INCLUDES A. Formed clay roofing tiles, complete with components and other required accessories

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

HOW TO FIGURE METAL ROOFING MATERIALS

HOW TO FIGURE METAL ROOFING MATERIALS HOW TO FIGURE METAL ROOFING MATERIALS 1. The first step in figuring your metal roofing is to make a sketch of it, complete with the roof measurements. Take the house below as an example: 52 R 12-8 P 19

More information

Sapphire Metal Tile Roofing System

Sapphire Metal Tile Roofing System Sapphire Metal Tile Roofing System Sapphire Metal Tile Roofing Benefits of Sapphire Metal Tile - Beauty and function - Tile Beauty, Steel Strength, Lasts a lifetime - Excellent long term investment - Pays

More information

Central Span. Product Guide 16" COVERAGE HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

Central Span. Product Guide 16 COVERAGE HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES Central Span Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 2" 16" COVERAGE Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_CentralSpan_180201

More information

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK A. 1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb

More information

MultiLok-24 Guide Specifications conforming to C.S.I. standards. A Division of ASC Profiles

MultiLok-24 Guide Specifications conforming to C.S.I. standards. A Division of ASC Profiles MultiLok-24 Guide Specifications conforming to C.S.I. standards A Division of ASC Profiles AEP SPAN MultiLok-24 Guide Spec i fi ca tions MANUFACTURER - AEP SPAN 5100 East Grand Avenue, Dallas, TX 75223,

More information

Metafor Panel System Installation Guide

Metafor Panel System Installation Guide Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE

More information

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017] [Change these specifications as needed. Use this sample proposal at your own risk. This is a simple, general proposal and is not meant to be a comprehensive proposal for all situations or projects. If

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. TYPES OF COVERING 110 BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Substrate: Plywood to

More information

SECTION METAL ROOFING MASTER SPECIFICATION

SECTION METAL ROOFING MASTER SPECIFICATION SECTION 07 41 13 METAL ROOFING MASTER SPECIFICATION PART I - GENERAL REQUIREMENTS 1.01 DESCRIPTION OF WORK: A. Section Includes: The extent of each type of preformed metal roofing panel as indicated on

More information

StrongSeam SSFF1 Panel

StrongSeam SSFF1 Panel StrongSeam SSFF1 Panel Installation Manual May 2016 12 TO 24 COVERAGE CLIP OFFSET STRIATED PANEL (2 STRIATION BEADS ON PANEL) 0.875 0.9375 26 ga. & 24 ga. UL90 #529 UL2218 Class IV/Impact UL790 Class A/Fire

More information

CUSTOM STEEL BUILDINGS

CUSTOM STEEL BUILDINGS CUSTOM STEEL BUILDINGS Table of Contents Why American Building Components? ABC is a national manufacturer of high-quality steel products established to serve do-it-yourselfers, homeowners, suburban farmers

More information

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations LIP-LO Table of ontents Product Page No. Product Page No. Panel Information lip-loc Panel Profile... PL-2 Panel Overview... PL-2 Flashing Profiles Eave... PL- leat... PL- Box Gutter... PL- Box Gutter End...

More information

General. 2. Design. 3. Anchor Bolts And Foundations. 4. Drawings. 5. Structural Framing. 6. Roof Covering Nucor Classic Roof Panel

General. 2. Design. 3. Anchor Bolts And Foundations. 4. Drawings. 5. Structural Framing. 6. Roof Covering Nucor Classic Roof Panel The following Nucor Building Systems Specification Guide provides the owner or design professional a detailed description of all standard Nucor Building Systems (NBS) products. This guide is designed to

More information

RPR Insul-Mate Sheet and Roll Jacketing

RPR Insul-Mate Sheet and Roll Jacketing RPR Insul-Mate Sheet and Roll Jacketing ALUMINUM PRODUCTS Rolled Jacketing Sheeting (Flat and Corrugated) Cut to Length Cut & Rolled Width/Length: 36 and 48 wide 100, 50 and cut to length (thicker gauges

More information

DRAWING INDEX Description

DRAWING INDEX Description DRAWING INDEX Qty. Description TOOL LIST PAGE #1 PANEL & PANEL RACK HANDLING TIPS 2 BASIC BUILDING COMPONENTS 3 ELEVATIONS 4 MATERIALS LIST 5 BUILDING LAYFLAT 6 FOUNDATION PREPARATION PLAN VIEW 7 BASE

More information

RESIDENTIAL ROOFING PRODUCT GUIDE

RESIDENTIAL ROOFING PRODUCT GUIDE RESIDENTIAL ROOFING PRODUCT GUIDE SHINGLES / LAMINATED LIMITED DESIGN PRODUCT SPECIFICATIONS WARRANTY CERTIFICATIONS U.L. Shadowtone Choose From Classic & ANC HERITAGE 30 HERITAGE 50 12 x 36-3/8 78 Shingles

More information

LUX Specifications. Section S - Preformed Steel Siding

LUX Specifications. Section S - Preformed Steel Siding Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of

More information

UNA-CLAD Metal Roofing Systems Application Guide

UNA-CLAD Metal Roofing Systems Application Guide UNA-CLAD Metal Roofing Systems Application Guide UC-3 Double-Lock Architectural Series UC-4 No-Clip Architectural Series UC-6 Double-Lock Structural Series UC-14 Snap-Lock Standing Seam Series March 22,

More information

Architectural. Technical/Installation Information

Architectural. Technical/Installation Information Technical/Installation Information IMPORTANT NOTICE This information is designed to assist you in product selection, detailing and application. MBCI is prepared and staffed to provide professional assistance

More information

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

Guide Specification SDP 200

Guide Specification SDP 200 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]

More information

Top Ten List: What Gets Metal Roof Designers in Trouble?

Top Ten List: What Gets Metal Roof Designers in Trouble? Top Ten List: What Gets Metal Roof Designers in Trouble? Brian Gardiner, FRCI, RRC, CCS BMG Enterprises, LLC 180 elvira, Canyon lake, TX 78133 Phone: 512-784-3791 e-mail: brian.bmgent@gmail.com Charlie

More information

PROJECT STATEMENT OF WORK ROOFING PHASE AREA CAMP BLANDING JOINT TRAINING SITE STARKE, FL 32091

PROJECT STATEMENT OF WORK ROOFING PHASE AREA CAMP BLANDING JOINT TRAINING SITE STARKE, FL 32091 PROJECT 214020 STATEMENT OF WORK ROOFING PHASE 2 4800 AREA CAMP BLANDING JOINT TRAINING SITE STARKE, FL 32091 1. SCOPE: Camp Blanding Joint Training Site requires the services of a Florida Licensed General

More information

M-Loc. Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 36" COVERAGE

M-Loc. Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 36 COVERAGE M-Loc Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 13 /" 36" COVERAGE 6" Copyright 2018, Central States Manufacturing, Inc., All Rights Reserved. D C GUID_PROD_MLOC_180201

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

HANDBOOK OF CONSTRUCTION DETAILS

HANDBOOK OF CONSTRUCTION DETAILS HANDBOOK OF CONSTRUCTION DETAILS ARCHITECTURAL PRODUCTS FOR THE BUILDING INDUSTRY 12" SSR, Decor-Flush 7, Amp Lok, Double Lock, GrandCurve, High Seam, Posi-Lock Soffit, Slim Seam 7, Snap-on-Batten, Snap-On-Seam,

More information

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation Hip Detail Hip Detail STANDARD Mineral fibre insulation ENHANCED Hip flashing with 150mm sealed butt straps Panels site cut to suit rake angle Apex dam (Ref: LP1/A) Rake cut profiled filler sealed top

More information

Guidelines for

Guidelines for Page1 Guidelines for Weather Tightness Warranty For Standing Seam Metal Panels General Today s metal roofing industry is faced with growing demand for warranties that help it compete with other types of

More information

Residential Building Inspections

Residential Building Inspections Residential Building Inspections Foundations, Grade Beams, Pile Caps, Foundation Pads 1. All trenches or excavations and formwork shall be in accordance with the size(s) and configuration(s) as per approved

More information

T-Rib Roofing System

T-Rib Roofing System T-Rib Roofing System Installation Manual 3449 Hempland Road Lancaster, PA 17601 (717) 397-2741 308 Alabama Blvd. Jackson, GA 30233 (770) 775-4484 World Wide Web: www.fabral.com E-Mail: fabinfo@fabral.com

More information

Jackson Plant: 308 Alabama Blvd. Jackson, GA (800) /Fax: (800)

Jackson Plant: 308 Alabama Blvd. Jackson, GA (800) /Fax: (800) Jackson Plant: 308 Alabama Blvd. Jackson, GA 30233 (800)884-4484/Fax: (800)765-4484 Idabel Plant: Rt. 3 Idabel, OK 74745 (800)926-8509/Fax: (800)289-6007 Headquarters: Lancaster Plant: 3449 Hempland Road

More information

SECTION CONCRETE ROOF TILE

SECTION CONCRETE ROOF TILE SECTION 07321 CONCRETE ROOF TILE Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2005-2011 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 RELATED SECTIONS A. Section 06100

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

SECTION MANUFACTURED ROOF AND WALL PANELS SECTION SHEET METAL ROOFING

SECTION MANUFACTURED ROOF AND WALL PANELS SECTION SHEET METAL ROOFING SPECIFICATIONS www.englertinc.com MANUFACTURER ENGLERT, INC. 1200 Amboy Avenue Perth Amboy, New Jersey 08861 Tel: (732) 826-8614 Fax: (732) 826-8865 PART I - GENERAL 1.01 WORK INCLUDED SECTION 07410 -

More information