1 1 Exam Prep 2014 Florida uilding ode -Energy onservation Questions and nswers 1. steam type heating system has a fluid design operating temperature of 275 degrees Fahrenheit and a nominal pipe diameter of one inch. The minimum pipe insulation should be how many inches? steam type heating system has a fluid design operating temperature of 275 degrees Fahrenheit and a nominal pipe diameter of one and one half inches. The minimum pipe insulation should be how many inches? The estimated total cooling of a central air conditioner in TU's during its normal usage period for cooling (not to exceed 12 months) divided by the total electric energy input in watt-hours during the same period is? FUE SHR EET SEER 4. The estimated total cooling of a central air conditioner in tu's during its normal usage period for cooling (not to exceed 12 months) divided by the total electric energy input in watt-hours during the same period is called the Energy Efficiency Ratio. verage Estimated Real Seasonal 5. The outer jacket of a flexible duct section be interposed between the flange of the duct collar fitting and the flexible duct. Shall not Shall Requires flame protection to nd a snap lock must 1 Exam Prep Florida uilding ode, Energy onservation 1
2 6. The maximum air leakage in FM s for a 3/0 by 7/0 commercial entrance glazed door is? Opaque Swinging doors require a U-value of when installed in a climate zone 3, group R? U-0.71 U-0.61 U-0.51 U Estell onstruction ompany is renovating an old commercial building. The assessed value of the renovation is $69,000. The assessed value of the structure is $71,690. Which is most correct? ompliance with the code may be required building permit may be necessary The renovation shall meet the energy requirements The decision belongs with the building official 9. Energy compliance is made part of the plans and requires certification by the? ontractor Engineer uilding s Owner ode Official 10. Mass common walls require an R-value of? Exam Prep Florida uilding ode, Energy onservation 2
3 11. When using R-value in thermal resistance designations, the term R-value means? The reverse of the time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces under steady state conditions per unit area The inverse of the time rate flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces under steady state conditions per unit area The inverse of the time rate of heat flow through a warm surface from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces under steady state conditions per unit area The reverse of time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces under steady state conditions per unit area 12. Which of the following does not require code compliance by license or registration? ondominiums partments Single family residential ommercial buildings 13. uval county is in moisture regime? F 14. wood house built in the middle region will require exterior wood frame walls to have an R-value of? The coefficient of heat transmission (air to air) through a building component or assembly, equal to the time rate of heat flow per unit area and unit temperature difference between the warm side and cold side air films is referred to as. Thermal conductance Thermal efficiency U-factor Thermal resistance 1 Exam Prep Florida uilding ode, Energy onservation 3
4 16. shall not contain electrical, plumbing or mechanical systems which have been designed to accommodate the future installation of heating or cooling equipment. Shell Temporary structures Residential residence Low energy buildings 17. is defined as, the basement walls, exterior walls, floor, roof, and any other building elements that enclose conditioned space. This boundary also includes the boundary between conditioned space and exempt or unconditioned space. Shell uilding thermal envelope Shell Low energy buildings 18. is the ratio of the solar heat gain entering the space through the fenestration assembly to the incident solar radiation. Solar heat gain includes directly transmitted solar heat and absorbed solar radiation which is then reradiated, conducted or convected into the space. Thermal conduction Solar heat gain coefficiency SEER ratio None of the above 19. The U Factor for an uninsulated metal door is roward county is in which designation for climate zone, moisture regime and warm humid designation? 2 warm humid 1 warm humid 1 humid The default glazed fenestration U-factor for a double pane metal skylight is Exam Prep Florida uilding ode, Energy onservation 4
5 22. The thickness of blown-in or sprayed roof/ceiling insulation (fiberglass or cellulose) shall be written on markers that are installed at least one for every throughout the attic space. 30 square feet 100 square feet 300 square feet 1000 square feet 23. is Energy derived from solar radiation, wind, waves, tides, landfill gas, biomass, or the internal heat of the earth. The energy system providing on-site renewable energy shall be located on the project site. on-site renewable energy Recycled energy Reciprocating energy Low energy consumption 1 Exam Prep Florida uilding ode, Energy onservation 5
6 1 Exam Prep 2014 Florida uilding ode -Energy onservation nswers nswer Section 1 Table Table TRE KNOWLEGE 4 TRE KNOWLEGE 5 TLE TLE Table R ommon walls/ceilings/floors R Table R301.1 R Table R TLE (2) TLE (1) Exam Prep Florida uilding ode, Energy onservation 6
7 NSWER KEY nswer Section 1 Table Table (Page 2.8) (Page 2.8) 5 Table Table (1) (Page 2.8) Table Table (Page 2.11) 1 Exam Prep Florida uilding ode, Energy onservation 7
1 Exam Prep Florida Building Code-Energy Conservation Edition Tabs and Highlights
1 Exam Prep Florida Building Code-Energy Conservation- 2014 Edition Tabs and s These 1 Exam Prep Tabs are based on the Florida Building Code-Energy Conservation-2014 Edition. Each 1 Exam Prep tabs sheet
More information1. The 2018 NCECC shall regulate the design and construction of buildings for the effective use of.
CHAPTER 1 [CE & RE] Scope & Administration WORKSHEET 1. The 2018 NCECC shall regulate the design and construction of buildings for the effective use of. a. energy b. natural resources c. manpower d. electric
More information1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7
Chapter 4 Residential Energy Efficiency [Residential structures include R-3 buildings; R-2 and R-4 buildings three stories or less in height built to the International Building Code (see IBC classifications)]
More informationThe 2009 International Residential Code and the American Recovery and Renewal Act of 2009
The 2009 International Residential Code and the American Recovery and Renewal Act of 2009 Background Recovery Act. The American Recovery and Renewal Act of 2009 requires that the Secretary shall make grants
More informationBoulder City NV Prepared by (Print Name) Signature Date
City of Boulder City Community Development Department Building & Safety Division 401 California Avenue Boulder City, NV 89005-2600 702-293-9282 (Main Line) 702-293-9392 (Fax) 2009 International Energy
More information2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016
CHEBOYGAN COUNTY DEPARTMENT OF BUILDING SAFETY 870 South Main Street P.O. Box 70 Cheboygan, Michigan 49721 Phone: (231) 627-8813 Fax: (231) 627-8454 www.cheboygancounty.net 2015 MICHIGAN UNIFORM ENERGY
More informationResidential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2
Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2 Building Name & Address: Subdivision: Lot #: Conditioned Floor Area: ft 2 State: County: Jurisdiction: Building
More informationRESIDENTIAL ENERGY EFFICIENCY
CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY This chapter has been revised in its entirety; there will be no marginal markings. SECTION 401 GENERAL 401.1 Scope. This chapter applies to residential buildings.
More informationApplying Energy Code to Existing Buildings
Applying Energy Code to Existing Buildings Massachusetts Energy Code Technical Support Program 1 Who Is Mass Save? Mass Save is an initiative sponsored by Massachusetts gas and electric utilities and energy
More informationCOMMERCIAL ENERGY EFFICIENCY
COMMERCIAL ENERGY EFFICIENCY Commercial buildings are all buildings that are not detached one- or two-family dwellings, multiple single-family dwellings (townhouses), or Group R-2, R-3 or R-4 buildings
More information2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.
Comparison Between Residential 2009 IECC with St Louis amendments, the 2015 IECC, and 2015 IECC w/ Building Codes Review Committee (BCRC) proposals: Climate Zone 4 Note: This document does not contain
More informationResidential Energy Code Update
Residential Energy Code Update www.phrc.psu.edu August 28 th, 2018 Brian Wolfgang Provider # 60114115 PPP ID: 1562 Description On May 1, 2018, the PA Uniform Construction Code (PA UCC) Review and Advisory
More informationConsumer Energy Tax Credit
Consumer Energy Tax Credit FLAMMABLE AND COMBUSTIBLE LIQUIDS 2009 IFC Overview of Tax Credit Energy efficiency incentives for upgrades to existing homes are now available for 2009 and 2010. These tax incentives
More informationBuilding Envelope
9.36.2. Building Envelope Module 2 BCBC 9.36. 2014 1 Richard Kadulski Architect 9.36.2. Building Envelope Focus is on total building performance, not just thermal insulation Heat transfer and air leakage
More information2010 Residential Energy Checklist: Additions/Alterations (Prescriptive Approach)
2010 Residential Energy Checklist: Additions/Alterations (Prescriptive Approach) Component Less than equal to 100 sq. ft. Addition Less than equal to 1000 sq. ft. Addition Greater than 1000 sq. ft. Addition
More informationORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:
ORDINANCE NO. XXXX AN ORDINANCE OF THE CITY OF LAWRENCE, KANSAS, REPEALING EXISTING CHAPTER V, ARTICLE 8 OF THE CODE OF THE CITY OF LAWRENCE, 2018 EDITION, AND AMENDMENTS THERETO, AND ENACTING, IN ITS
More informationThermal Bridging in Residential Construction
PHRC Webinar Series Tuesday, May 12, 2015 @ 1pm Thermal Bridging in Residential Construction Brian Wolfgang Housing Systems Specialist Pennsylvania Housing Research Center 219 Sackett Building University
More informationHardin County Planning and Development Commission
Location by Climate Zone: Hardin County (per Table N1101.2), and the entire state of Kentucky is located in Climate Zone 4, the HDD is 4000 to 4999. Building Requirements; Building Thermal Envelope The
More informationA Closer Look Inspection Service 2015 IECC Residential DFW area handout
103.2 Information required on construction documents 1. Designation of the Thermal Building Envelope on the plans 2. Insulation Material and their R Value 3. Fenestration U and SHGC values 4. Area weighted
More informationTruss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017
Truss Heel Heights and Energy Code Requirements Overview Revised 2/17/2017 SBCA has been the voice of the structural building components industry since 1983, providing educational programs and technical
More informationHome Improvement Energy Tax Credits Explained
Home Improvement Energy Tax Credits Explained Your Local Home Improvement Specialist WHITE PAPER Through The Emergency Economic Stabilization Act of 2008 (the Bailout Bill ) and The American Recovery and
More informationAPPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.
Chapter 1 101.1 Title. These regulations shall be known as the North Carolina Energy Conservation Code as approved by the North Carolina Building Code Council on March 11, 2008, to be effective January
More informationINTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE
INTENATIONAL CODE COUNCIL 09/10 CODE DEVELOPMENT CYCLE 09/10 FINAL ACTION AGENDA UPDATE #2 INTENATIONAL ENEGY CONSEVATION CODE Updated 10-22-10 October 25. 27-31, 10 CHALOTTE CONVENTION CENTE CHALOTTE,
More informationChapter 1: Compliance
Chapter 1: Compliance [101] Who Must Comply? All new residential construction must comply with the Washington State Energy Code (WSEC). Exceptions. Exempt from envelope requirements but needing to comply
More information2012 INTERNATIONAL ENERGY CONSERVATION CODE ADOPTION TOOLKIT OCTOBER 2012
2012 INTERNATIONAL ENERGY CONSERVATION CODE ADOPTION TOOLKIT OCTOBER 2012 Building energy codes and standards have an important impact on the multifamily industry. Today, apartment properties face new
More informationRecommended Amendments to the 2012 International Residential Code (IRC)
Issue: Insulation Requirements by Components- Basement Wall R-value and U-value 2012 IECC Section: Table N1102.1.1 and Table N1102.1.3 Modify the Tables as shown below: (Delete data, add new data) CLIMATE
More informationREScheck Software Version Compliance Certificate
REScheck Software Version 4.3.1 Compliance Certificate Project Title: Chow Residence Renovation Energy Code: 2009 IECC Location: Boston, Massachusetts Construction Type: Single Family Project Type: Addition/Alteration
More informationOntario s Building Code
Ministry of Municipal Affairs and Housing Ontario s Building Code ONTARIO ONLY PROPOSED CHANGE TO THE 2006 BUILDING CODE CHANGE NUMBER E-B-12-03-05 CODE REFERENCE Div. B 12.3.4.1. 12.3.4.2. DESCRIPTION
More informationResidential Energy Code Combustion Air and Make-Up Air
Residential Energy Code Combustion Air and Make-Up Air Presenters Don Sivigny Don.sivigny@state.mn.us 6651-284-5874 & Scott Nelson Scott.nelson@state.mn.us 651-284-5850 CCLD /DOLI History of the Energy
More informationA. GENERAL INFORMATION
STATE OF CALIFORNIA Prescriptive Residential Additions 300 Ft 2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CF1R-ADD-05-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE
More informationThermal Control in Buildings by John Straube (updated )
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 011 Thermal Control in Buildings 2006-11-02 by John Straube (updated 2011-12-12)
More informationFLORIDA BUILDING CODE Energy Code (Residential) 6 TH Edition (2017) Chapter 1 [RE]: Scope and Administration
FLORIDA BUILDING CODE Energy Code (Residential) 6 TH Edition (2017) Code Changes based on the document provided by DBPR - 2014 and 6th Edition (2017) Florida Building Code Comparison R101.4.1 Chapter 1
More informationNC ECC Commercial Training June 2011
Mathis Consulting Company North Carolina Energy Conservation Code: Commercial Prescriptive Provisions Mathis Consulting Company Building Solutions Chris Mathis 100+ Years of Experience as Building Scientists,
More informationPrescriptive Checklist for the 2015 Washington State Energy Code
Prescriptive Checklist for the 2015 Washington State Energy Code Chapter 51-11R WAC STATE BUILDING CODE ADOPTION AND AMENDMENT OF THE 2015 EDITION OF THE INTERNATIONAL ENERGY CONSERVATION CODE, RESIDENTIAL
More informationEnergy Efficiency For Housing
Ministry of Municipal Affairs and Housing Building and Development Branch MMAH Supplementary Standard SB-12 MMAH Supplementary Standard SB-12 Energy Efficiency For Housing 2016 update Draft for stakeholder
More informationEnergy Efficiency For Housing
Ministry of Municipal Affairs Building and Development Branch MMA Supplementary Standard SB-12 MMA Supplementary Standard SB-12 Energy Efficiency For Housing July 7, 2016 update Effective Date: July 7,
More informationIs Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards
Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards Is Yours? A home buyers guide to the energy efficiency requirements of the 2012 International Energy Conservation
More informationComparison Matrix of Florida Residential Building Energy Code and the International Energy Conservation Code (IECC) 2006
Comparison Matrix of Florida Residential Building Energy Code and the International Energy Conservation Code (IECC) 2006 Authors Mangesh Basarkar, Robin Vieira Publication Number FSEC- CR-1636-06 Copyright
More informationFLORIDA BUILDING CODE, ENERGY CONSERVATION Residential Building Thermal Envelope Approach FORM R
FORMS FLORIDA BUILDING CODE, ENERGY CONSERVATION Residential Building Thermal Envelope Approach FORM R402-2017 Climate Zone Scope: Compliance with Section R401.2(1) of the Florida Building Code, Energy
More informationCharter Township of Washington
Charter Township of Washington Building Department 57900 V an Dyke Washington, MI. 48094 Phone:(586) 786-0010 Ext. 211 Fax: 586-752-6463 2015 Michigan Residential Code Energy Worksheet for New Single-family
More informationSingle Family Residence Building Permits
Village of Northbrook Department of Building & Development Guide to: Designing, Documenting & Inspecting For Energy Code Compliance Single Family Residence Building Permits New Construction Additions Alterations
More informationManitoba Energy Code for Buildings. Part 3 Building Envelope
Manitoba Energy Code for Buildings Part 3 Building Envelope Rick Marshall, P. Eng, LEED AP September 17, 2014 Manitoba Energy Code for Buildings (MECB) Training Day Part 3 - Scope Part 3 is concerned with
More informationGRAYS HARBOR COUNTY TECHNICAL ASSISTANCE BULLETIN
GRAYS HARBOR COUNTY TECHNICAL ASSISTANCE BULLETIN 36 RESIDENTAL ENGERY CODE COMPLIANCE WORKSHEETS The attached compliance fms can be completed manually by visiting www.energy.wsu/edu/codes and using the
More informationInternational Code Council
International Code Council ICC 400-2012 edition Standard on the Design and Construction of Log Structures Public Comments Draft #1 The ICC Standard Development Committee on Log Structures (IS-LOG committee)
More information2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building
2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building Building Department 52700 Van Dyke, Shelby Township, MI 48316 Phone (586) 731-5969 Fax (586) 803-2099 building@shelbytwp.org
More information2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building
2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building Building Department 52700 Van Dyke, Shelby Township, MI 48316 Phone (586) 731-5969 Fax (586) 803-2099 building@shelbytwp.org
More informationSupplementary Standard SB-12. Energy Efficiency For Housing
Ministry of Municipal Affairs and Housing Building and Development Branch 2006 Building Code - Supplementary Standards Supplementary Standard SB-12 Energy Efficiency For Housing January 1, 2012 update
More information1. Each of the following is a compliance path option for energy conservation code compliance for Residential Buildings except.
2018 NC Energy Conservation Code Residential Building Module 2 CHAPTER 4 [RE] WORKSHEET 1. Each of the following is a compliance path option for energy conservation code compliance for Residential Buildings
More informationENERGY SAVINGS FOR LIFE
Design Characteristics of Spray Polyurethane Foam Insulation ENERGY SAVINGS FOR LIFE Spray Polyurethane Foam Insulation FEATURES Spray Applied Excellent Adhesion Lightweight Safe High Insulation Value
More informationRebates for Improvements Home Efficiency Program Fort Collins Utilities
Rebates for Improvements Home Efficiency Program Fort Collins Utilities Revised 03/04/2013 This matrix summarizes information regarding Home Efficiency Program rebates for improving homes in Fort Collins.
More information2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)
2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:
More informationERI vs. Performance Path: Which is better for the builder?
ERI vs. Performance Path: Which is better for the builder? Presented By Robby Schwarz Conclusion ANSI 301 Named the Energy Rating Index RESNET HERS ERI 2015 IECC ERI 2018 IECC ERI More to come The Code
More information2006 Building Science Press All rights of reproduction in any form reserved.
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 011 Thermal Control in Buildings 2006-11-07 by John Straube Abstract: Providing
More informationIECC - RESIDENTIAL - ENERGY TAC
IECC - RESIDENTIAL - ENERGY TAC W A R N I N G Copyright Notice: This document has been reproduced solely for considering proposed changes to the Florida Building Code with the permission of the International
More informationMichigan Energy Code Training and Implementation Program
Michigan Energy Code Training and Implementation Program 1.0 Hour Advanced Program Course Number 16202 Residential Energy Plan Review School of Planning, Design & Construction Michigan State University
More informationBuilding Department Informational Handout. Residential Window Replacement Requirements
City of Sonoma Building Department Informational Handout Residential Window Replacement Requirements Handout No: 28 Revised: 6/8/18 These requirements apply to the replacement of existing windows in residential
More informationThe Lower The HERS Score The Better. Tight Building Envelope. Renewable Energy Sources. Materials & Waste Management. Energy Efficient Lighting
Green Guide 2018 Tight Building Envelope Controlling, thermal flow and moisture flow using advanced framing techniques, sophisticated insulation, air sealing tight ducts and air barriers to prevent air
More informationFeature Zone IECC 2009 IECC
Feature Zone 3 2006 IECC 2009 IECC Window U factor 0.65 0.50 Skylight U factor 0.65 0.65 Window SHGC 0.40 0.30 Ceiling R value 30 30 Wood frame R value 13 13 Mass wall R value 1 5 5/8 Floor R value 19
More informationResidential Requirements of the Texas Energy Code 2009 IRC Chap 11
BUILDING ENERGY CODES UNIVERSITY Residential Requirements of the Texas Energy Code 2009 IRC Chap 11 Ken Baker PNNL-SA-65859 The Family of I-Codes International Building Code International Mechanical Code
More informationENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010
ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Below is the product criteria for ENERGY STAR qualified residential windows, doors, and skylights sold in Canada
More informationC H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS
C H A P T E R 3 Completing the Residential Analysis Worksheet The Residential Analysis Worksheet is designed to help the reader in making the preliminary calculations necessary to complete Forms 600A-04,
More informationSuccess with 2009 IECC: Tech Tips for Builders. Insulation. Copyright 2014 Advanced Energy. All Rights Reserved
Success with 2009 IECC: Tech Tips for Builders Insulation Copyright 2014 Advanced Energy. All Rights Reserved Insulation 1. For vented attics, install wind baffles on top of all exterior walls, leaving
More information**Section C and R ; change to read as follows:
Recommended Amendments to the 2012 International Energy Conservation Code North Central Texas Council of Governments Region (Climate Zone 3 of the IECC) The following sections, paragraphs, and sentences
More information1 Exam Prep Manual J Residential Load Calculation 8 th Edition Tabs and Highlights
1 Exam Prep Manual J Residential Load Calculation 8 th Edition Tabs and Highlights These 1 Exam Prep tabs are based on the Manual J Residential Load Calculation for Small Commercial Buildings, 8 th Edition.
More informationHomes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours?
Homes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours? A home buyer s guide to the energy efficiency requirements of the 2012 International Energy Conservation Code Nebraska
More information3. Defining the Proposed and Standard Designs
2008 Residential ACM Manual June 2007 Workshop Draft Page 3-1 3. Defining the Proposed and Standard Designs The space conditioning energy budget for the residential Standards is a custom budget, that is,
More informationWelcome IECC Fundamentals. Your Instructor today is: William H. (Bill) Hudson, CBO, MCP
Welcome 2009 IECC Fundamentals Based on the 2009 International Energy Conservation Code Meet the instructor Participant introductions Why are you here? Your Instructor today is: William H. (Bill) Hudson,
More informationProject Type: New Home Addition Alteration (Describe)
MICHIGAN ENERGY CODE WORKSHEET City of Mt. Pleasant - Building Safety Department 320 W. Broadway Street, Mt. Pleasant, MI 48858 (989) 779-5347 www.mt-pleasant.org Effective September 20, 2017, all NEW
More informationPlan Check & Field Inspection Guide
Plan Check & Field Inspection Guide 1992 MEC, 1993 MEC, and 1995 MEC Inside This Guide Plan Check Field Inspection Plan Check Building plans and specifications must be submitted with each building application
More informationHome Energy Score. Learn more at homeenergyscore.gov. Uses more energy. Uses less energy Milvia Street Berkeley, CA 94704
ADDRESS 2120 Milvia Street Berkeley, CA 94704 HOME SIZE YEAR BUILT AIR CONDITIONING 1,450 square feet 1970 Your home's current score 3 Uses more energy 1 2 3 4 5 6 7 8 9 10 Uses less energy Learn more
More information2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)
2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:
More informationBaker Neighborhood Energy Efficiency Workshop B A K E R H I S T O R I C N E I G H B O R H O O D A S S O C I A T I O N
Baker Neighborhood Energy Efficiency Workshop B A K E R H I S T O R I C N E I G H B O R H O O D A S S O C I A T I O N Energy Efficiency Workshop Reid Beauchamp, BPI Building Analyst Reid.Beauchamp@clearesult.com
More informationEnergy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort
Please add relevant logo here Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Presented by: Peter J. Arsenault, FAIA, NCARB, LEED-AP Disclaimer: This presentation was developed by
More information2009 IECC Fundamentals. Your Instructor today is: William H. (Bill) Hudson, CBO, MCP. Based on the 2009 International Conservation Energy Code
2009 IECC Fundamentals Based on the 2009 International Conservation Energy Code Your Instructor today is: 2 William H. (Bill) Hudson, CBO, MCP 3 1 Standards Technical Panel for Energy Management Equipment,
More information2018 IECC Residential Provisions with Corresponding IRC Sections
Providing effective energy strategies for buildings and communities 2018 IECC Residential Provisions with Corresponding IRC Sections 11.14.2018 Who we are We assist buildings and communities in achieving
More informationActivity 2.2.3A Heat Loss and Gain (Revised)
Activity 2.2.3A Heat Loss and Gain (Revised) Introduction When the winter design temperature is below 60ºF, the International Residential Code requires a dwelling to have heating facilities capable of
More informationName of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one
2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:
More informationName of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one
2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:
More informationSectIon Energy Effldency
SectIon 9.36. Energy Effldency The objective of this Code is to limit the probability that, as a resuft ofthe design or construction ofthe building, resources will be used in a manner that will have an
More informationInterpretation Variables and Common Areas of Confusion. Of the 2009 IECC
Interpretation Variables and Common Areas of Confusion Of the 2009 IECC 1. (Mandatory) provisions vs. (Prescriptive) provisions: The IECC contains flexibility by allowing different approaches to achieve
More informationEnergy Code Compliance:
Energy Code Compliance: Wood-Frame Buildings and the IECC Presented 4 March 2015 by Andrew Klein, P.E. Disclaimer: This presentation was developed by a third party and is not funded by WoodWorks or the
More informationExcerpts from the Uniform Building Code. (UBC) For The US
Excerpts from the Uniform Building Code (UBC) For The US Index 4301 FIRE-RESISTIVE STANDARDS 1. Section 4301(a) Standards of Quality 2. Section 4301(b) Definitions 4304 WALLS AND PARTITIONS 1. Sec.4304(a)
More information2014 British Columbia Building Code Changes
2014 British Columbia Building Code Changes A City of Prince George interpretation of the 2014 Building Code Changes for 9.32 & 9.36 The following changes reflect the most notable revisions and staff interpretations.
More informationCHAPTER 1 ADMINISTRATION AND ENFORCEMENT
CHAPTER 1 ADMINISTRATION AND ENFORCEMENT SECTION 101 SCOPE AND GENERAL REQUIREMENTS 101.1 Title: Chapters 1 through 10 of this Code shall be known as the "Washington State Residential Energy Code" and
More informationA LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting
A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS Presented by: Shaunna Mozingo, Colorado Code Consulting WHAT CAN WE EXPECT TO SEE? Some consensus on enough is enough for now - No real roll backs, no real
More informationRESIDENTIAL CODE OF NEW YORK STATE
Part IV Energy Conservation CHAPTER 11 ENERGY EFFICIENCY There are no margin bars shown in this chapter due to its substantial revision. SECTION N1101 GENERAL N1101.1 Scope. This chapter regulates the
More informationEnergy Efficiency Requirements 9.36
The following information has been obtained from the HPO Illustrated Guide, Energy Efficiency Requirements for Houses in British Columbia, BCBC 9.36 & 9.32, Building Officials Association of British Columbia
More informationSelecting Energy Efficient Replacement Windows in Florida
Selecting Energy Efficient Replacement Windows in Florida www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are
More information2004 FLORIDA BUILDING CODE, CHAPTER 13, SUBCHAPTER 6, vs 2006 INTERNATIONAL ENERGY CONSERVATION CODE Residential Compliance Requirements
2004 FLORIDA BUILDING CODE, CHAPTER 13, SUBCHAPTER 6, vs 2006 INTERNATIONAL ENERGY CONSERVATION CODE Residential Compliance Requirements Florida Code SECTION 13-600 ADMINISTRATION IECC Code 13-600.0 Methods
More informationInspection of New One- and Two- Family Dwellings
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Inspection of New One- and Two- Family Dwellings Planning and Development
More informationNew Hampshire Residential Energy Code
CHAIRMAN STATE OF NEW HAMPSHIRE EXECUTIVE DIRECTOR Thomas B. Getz AND SECRETARY COMMISSIONERS Debra A. Howland Susan S. Geiger TDD Access: Relay NH Nancy Brockway 1-800-735-2964 Tel. (603) 271-2431 FAX
More informationERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.
ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD 90.1-2010 (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings March 8, 2018 The corrections listed in this errata sheet apply to
More informationGeneral Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:
New Hampshire Residential Energy Code Application Town of Sutton for Certification of Compliance for New Construction, Additions and/or Renovations to be submitted with completed building permit (EC-1
More informationCODE ACTION AMENDMENTS
UCC Review and Advisory Council OFFICIAL Record of 2015 I-Code Review May 1, 2018 CODE ACTION AMENDMENTS 2015 ADMIN ADOPT None 2015 IWUIC ADOPT None 2015 IFC ADOPT None 2015 IBC ADOPT Delete Section 913.2.2
More informationThis article will address the test methods used to determine R-values and their relative degree of accuracy.
Insulation R-value, What does it really mean? Every designer knows that the R-value of a material is important in specifying insulation products. Regulations abound that require minimum R-values for wall,
More informationTHE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012
THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012 Compliance with the code for new residential construction, additions, and substantial remodels will
More informationIECC Residential Significant Changes Summary. Tier I
2009-2015 IECC Residential Significant Changes Summary Tier I R401.2 Compliance options for compliance are now prescriptive path, Total UA (which is part of prescriptive), Performance and the new Energy
More informationMichigan Energy and Cost Savings
BUILDING TECHNOLOGIES PROGRAM Michigan Energy and Cost Savings for New Single and Multifamily Homes: 2012 IECC as Compared to the Michigan Uniform Energy Code 1 2012 IECC AS COMPARED TO THE MICHIGAN UNIFORM
More informationENERGY STAR Qualified Homes National Program Requirements, Version 3.0
Qualifying Homes The following homes are eligible to earn the ENERGY STAR: Single-family homes; Units in multi-family buildings that are three stories or less; Units in multi-family buildings that are
More informationERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.
ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD 90.1-2010 (I-P edition) Energy Standard for Buildings Except Low-Rise Residential Buildings April 17, 2013 The corrections listed in this errata sheet apply to
More information