NTA SIMPLY CERTIFIED. Our strength is our people.

Size: px
Start display at page:

Download "NTA SIMPLY CERTIFIED. Our strength is our people."

Transcription

1 Providing Testing, Inspection, Certification & Verification Services to Ensure that Products, Services & Systems Meet the Quality, Safety & Performance Required

2 NTA SIMPLY CERTIFIED NTA, Inc partners with traditional builders, building material suppliers, factory built manufactured / modular home and commercial manufacturers, RV manufacturers, and other industries to provide independent verification of quality and standards compliance in the product consumers purchase - from an entire home to a single home improvement product purchased from the local lumber yard. NTA SIMPLY CERTIFIED products deliver numerous diverse benefits to residential and commercial builders, code officials, manufacturers and suppliers across the building industry. Our strength is our people. The strength and quality of our service is based upon the size and depth of our staff, and upon our personal commitment to give you our best. NTA Inc. employs full time engineers with professional registrations in all 50 states and the District of Columbia. In addition to Professional Engineers, NTA Inc. employs professionals that combined have completed over 300 building code examinations. We have over 190 inspector licenses/certifications. To better serve our clients, NTA Inc. operates out of five regional offices throughout the Midwestern, Eastern, and Southern United States. Additionally, NTA s Test Facility in Nappanee, Indiana provides testing services to the entire building industry. NTA Certification Provides local officials greater confidence in code compliance, reducing the number of field-related issues and saving valuable time on site. Adds value to product, passively increasing margins. Serves as a primary sales point, increasing product sales. Increases product credibility with consumers and regulatory agencies. Establishes the high quality standards employed by the manufacturer. Creates good corporate citizenship on the part of the builder or manufacturer. David R Tompos, P.E., Company Founder, Vice President, Director of Sales NTA SIMPLY CERTIFIED is synonymous with quality. unbiased. independent testing across the spectrum of residential and commercial construction. Call a NTA Certified professional today.

3 NTA, Inc. has over 70 highly trained professionals working across the United States and Canada ready to provide you with the following services: Certification (ISO Guide 65) Testing (ISO17025) Inspection (ISO 17020) Third Party DAPIA/IPIA services, Manufactured Housing Commercial, Industrial, and Residential Modular plan review Commercial, Industrial, and Residential Modular design and consulting Park Model Certification Design, Engineering and Drafting Re-labeling (recertification) of existing Modular buildings Third-party in plant Quality Audit inspections Modular Home Testing Conventional building code compliance, design and plan review Canadian and Domestic Submittal Packages California Third Party Certification of Composite Wood Products (Formaldehyde TPC-025) ICC, ASTM materials testing and failure analysis Building Code Consulting Services Compliance Testing Services Green Building Certification David A Tompos President Eric Tompos, P.E., S.E., C.B.O. Vice President, Director of Compliance

4 Professional Certification, Testing, and Quality Audits Exceptional Personal Service... Product Certification and Testing Services NTA, Inc. is an independent quality assurance and materials testing agency capable of providing a wide range of structural product testing and inspection services. NTA, Inc. has the equipment and expertise to measure the structural performance of building materials and components using industry-standard engineering methods of evaluation. If no standard test method exists for your product or application, NTA, Inc. can develop a custom testing service method to suit your needs. In addition to testing, our network of inspectors, located across the United States, allows us to assess in-plant quality control procedures; ensuring consistent quality of your product for code compliance. Professional Services Every test procedure is overseen by a registered Professional Engineer. Our engineers not only ensure the integrity of your test, but they also help solve any deficiencies identified by the test. Additionally, our professionals will work with you to develop a testing regimen tailored to your product. Our staff's extensive experience, coupled with state-of-the-art equipment, enable us to obtain reliable and precise data for HUD compliance. Dale Arter, Director of Certification and Testing What do you want to test or certify today? Adhesives o SIP Panel Adhesive, Wall Adhesives, Shear, Tensile, Bond Strength, Creep Resistance, Accelerated Aging, Composite and Engineered Lumber Adhesives, Adhesive Shearwalls Fire Testing o Cabinet Doors, Particle Board, Plywood, FMVSS 302 Fasteners o Metal Connector Plates (Trusses), Lag Bolts, Nail, Screws, Gypsum Wallboard o Physical Properties Plastics, Plastic Lumber and Composite Lumber o Composite Decking, Guard Railing, Footing Pads, Structural Plastics Structural Assemblies o Structural Insulated Panels (SIP panels), Metal Roofs, Structural Sheathing, Windborne Debris, Metal Connector Plates, Light Gauge Steel, Engineered lumber (LVL), Foam Plastics, Air Infiltration, Fasteners Assemblies Termite Testing o Termite Resistance of Wood Products Roof and Wall Assemblies o Vapor Transmission, Underlayment, Laminated Sheathing, Weather Resistance Environmental o High Temp Ovens, High and Low Humidity, Accelerated Aging Metals o Tensile and Yield Strength Testing Plumbing Fixtures o Ceramic Tile and Slip Resistance Wood and Wood Product Emission o California Third Party Certification (TPC-025) for Composite Wood Formaldehyde Qualification o Formaldehyde Testing Comparative Testing o Product Comparative Testing Paperboard o TAPPI Standards

5 Miami Dade Approved Laboratory o Wind Borne Debris City of Los Angeles Approved Laboratory o ISO Scope Texas Department of Insurance Approved Laboratory o ISO Scope HUD Structural Certification Testing o 24 CFR 3280 Park Model Certification NTA Testing Facility Exceptional Personal When testing with NTA, Inc. you will work directly with Dale Arter, NTA's Director of Testing. From the construction of the specimens to compilation of the data, Dale oversees every aspect of testing. This direct line of communication ensures your testing objectives are met and any questions or last minute changes can be addressed accurately and quickly. Overall Satisfaction Often, when testing is required, time is of the essence. At NTA, we strive to serve your testing needs in a timely and professional manner. Quotes are often issued in several days-- not several weeks. And, tests are often completed in several weeks--not several months. Reports are typically issued within two days of test completion. As always, quotes are free. Contact Dale Arter for a free quote on your next project. Our professionals take pride in their work, and it shows in our reports. Our clients prefer NTA's test reports because they provide precise documentation of results and methodologies in an easy-to-understand format. NTA's reports are fully illustrated with photographs, diagrams, and graphs to clearly convey all details while allowing for rapid assessment of overall results. Each report is thoroughly reviewed for technical accuracy and overall quality before it leaves our lab. When writing your report, NTA will gladly incorporate any additional details or analysis you may require. Ryan Lehman, Laboratory Manager Contact NTA's Product Certification and Test Facility: 257 East Randolph St. Nappanee, IN Dale Arter, Director of Product Certification and Testing Phone: Ext darter@ntainc.com Ryan Lehman, Laboratory Manager Phone: Ext rlehman@ntainc.com Doug Berger, Certification Program Engineer Phone: Ext dberger@ntainc.com

6 Factory Built Structures Services Commercial and Residential Modular Services NTA s engineers have earned over 200 licenses and certifications in order to perform modular inspections in every state with a modular program. Recently, NTA, Inc. partnered with Intertek, giving them the ability to perform modular inspections for Canada. Inspectors ensure that all elements of the modular construction are meeting National Building Code requirements. NTA, Inc. continues to partner with the Modular Building Systems Association (MBSA) to stay abreast of consumer demands and industry news. As an independent indoor air quality assurance and testing agency, NTA is capable of providing a wide range of inspection and testing services for your project, including all FEMA and government agency projects. Chuck Osterday, Modular Coordinator DAPIA and IPIA Services NTA, Inc. has a network of inspectors across the country to provide manufacturers with a cost effective means of on-site, alternative inspections for the Manufactured Housing Programs. NTA, Inc. is approved by the Federal government to not only certify plants for HUD on their ENERGY STAR qualifications, but can also complete in-plant inspections and perform quality audits. NTA, Inc. is a partner in the EPA ENERGY STAR Labeling Program for Manufactured Housing. NTA, Inc. provides everything necessary to get your facility ENERGY STAR certified. Services include: Whole house leakage testing; Duct leakage testing; Construction diagnostics and consulting Energy efficiency consulting; Plant certification; and Ongoing field evaluation services. Doug Mills, Director of DAPIA Services Contact NTA's Factory Built Structures Department: 305 North Oakland Ave. Nappanee, IN Chuck Osterday, Modular Coordinator Doug Mills, Director of DAPIA Services Phone: Ext 314 Phone: Ext dmills@ntainc.com dmills@ntainc.com

7 Engineering Design Services Engineering Design Services With licensed engineers in all 50 states, including the District of Columbia, NTA offers an array of engineering services to fit each client s unique needs; services include design, design review, plan review, design approval, inspection, and drafting for residential, commercial, and industrial buildings in every state, as well as for all building codes. NTA s staff is made up of highly qualified engineers, PE s (Professional Engineers) and design engineers, ensuring that each client receives top of the line customer service and quick project turnaround. For new or existing construction, NTA can provide complete structural engineering calculations and analysis in accordance with adopted codes. In addition, NTA uses meticulous design software, which was developed, in-house, by NTA s own Professional Engineers. NTA has over 570 years of combined experience and can complete even the most demanding projects. Ryan Boring, P.E., Director of Engineering Services What do you want to engineer today? (Wood & Steel Truss, High Wind Design, Modular, Residential Design, Modular Commercial Design, Foundation Design, Post Frame, Design, Structural Insulated Panels, Plan Review and Approval, Heavy Timber Frame Design, Seismic Design) Computer Aided Design (CAD) Services CAD Services NTA is committed to providing CAD Design services throughout the building industry. From new to revision work, technical detailing or submittal packages NTA is prepared and ready to help your company stay ahead within today s demanding markets. NTA can provide mechnical and electrical drafting, full time or part time support or even help on special large projects. Contact NTA today to help on your next drafting project. Coraya Siwy., Director of CAD Services Contact NTA's Engineering Department: Contact NTA's CAD Department: 305 North Oakland Ave. 305 North Oakland Ave. Nappanee, IN Nappanee, IN Ryan Boring, Director of Engineering Services Coraya Siwy, Director of CAD Services Phone: Ext 329 Phone: Ext rboring@ntainc.com ccraft@ntainc.com

8 Why NTA s Testing Facility Companies that need a way to professionally, precisely and accurately test their products or materials in a controlled laboratory environment will often choose to hire an independent laboratory testing facility because of the expertise and specialized technology they will usually have for meeting a variety of laboratory testing needs. Laboratory testing facilities will usually offer a number of different services to their customers including product testing, reverse engineering, lab management, product failure investigations and raw material certification using the latest in laboratory testing technology. When comparing potential laboratory testing facilities, it is important to select a testing laboratory that offers the specific testing technology that you require and that has experience in testing products similar to the ones you need tested. Having your products or materials professional tested in a laboratory can often improve their quality and guard against serious product failures. When choosing a laboratory testing facility, be sure to verify that they have the proper certifications needed to test certain products and to perform certain types of tests. NTA, Inc. carries many certifications including but not limited to ISO 17025, ISO 17020, and ISO Guide 65 (IAS Accredited Laboratory). This includes accredited testing programs in many areas of accreditation such as The American Association for Laboratory Accreditation offers a variety of different laboratory accreditation programs in a variety of field such as Construction Materials, Calibration, Chemical, Environmental, Geotechnical, Mechanical and Nondestructive. After all of the tests have been completed, NTA s testing facility can usually be able to provide their clients with a detailed analysis of the testing results and specific findings so that improvements can be made. With this support our clients feel comfortable with the tests that have been performed and they actually learn more about their product.

9 NTA Product Certification NTA, Inc. Product Certification program is recognized and accredited by the International Accreditation Service Inc (IAS) a subsidiary of ICC. NTA, Inc. (PCA-102) is accredited to meet the requirements of ISO/IEC Guide 65 General requirements for bodies operation a product certification systems. NTA Product Certification Program evaluates products and documentation, and certifies that the listed product is in compliance with NTA and nationally recognized standards. A Listing Report is issued along with a unique listing mark and number. NTA makes available on the NTA web site copies of specific listing reports to assist designers, users, and code officials in the use of the listed building product. The Product Certification Process is described in NTA ISSOP 3.2c and is available upon request. On going follow up audits by NTA at the manufactures facilities checks that the listed product continues to meet the product certification report throughout the listing period. NTA Product Certification Scope of Accreditation contains the following: Structural Insulated Panels (SIPs) Formaldehyde Emissions CARB Third Party Testing ( CARB TPC-25) Cabinets Structural Plastics Thermal and Moisture Protection Adhesives Fasteners Gypsum Wallboard Structural Assemblies Plumbing Fixtures Metal Plate Connected Trusses Light Gauge and Cold Formed Steel Components Deck Board and Guardrail Systems

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

Standard test method for wood preservatives by laboratory soil-block cultures

Standard test method for wood preservatives by laboratory soil-block cultures IAS Accreditation Number Company Name Address Contact Name TL-259 257 East Randolph Street Nappanee, Indiana 46550 Dale Arter Director of Testing & Certification Telephone (574) 773-7975 Effective Date

More information

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( ) PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels (06 12 16) Report Holder General Panel Corporation PO Box 279 2604 Sunset Drive Grenada, Mississippi

More information

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( ) PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels (06 12 16) Report Holder Thermocore Panel Systems, Inc. 1801 Hancel Parkway Mooresville, Indiana

More information

SECTION STRUCTURAL INSULATED PANELS

SECTION STRUCTURAL INSULATED PANELS SECTION 06120 STRUCTURAL INSULATED PANELS Copyright 2011-2012 Korwall Industries, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural Insulated Roof Panels. B. Structural Insulated

More information

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures. SECTION 06 12 00 STRUCTURAL INSULATED PANELS ------------------------------------------------------------------------------------------------------------ PART 1- GENERAL ----------------------------- 1.1

More information

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures. SECTION 06 12 00 STRUCTURAL INSULATED PANELS ------------------------------------------------------------------------------------------------------------ PART 1- GENERAL ----------------------------- 1.1

More information

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( ) PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels (06 12 00) Report Holder ACME Panel Company 1905 West Main St. Radford, VA 24141 Manufacturing

More information

Session: Approving and Selecting Building Products with Confidence - What To Look for in Evaluation Reports

Session: Approving and Selecting Building Products with Confidence - What To Look for in Evaluation Reports Session: Approving and Selecting Building Products with Confidence - What To Look for in Evaluation Reports Approving and Selecting Building Products with Confidence - What To Look for in Evaluation Reports

More information

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614) Lamit Industries, Inc. 710 Marion Road Columbus, Ohio 43207 P-(614)444-3010 F-(614)444-4264 info@lamitindustries.com www.lamitindustries.com SECTION 06120 STRUCTURAL INSULATED PANELS PART 1 GENERAL 1.01

More information

Listing Report: MUR Reissue Date: 12/07/17 This report is subject to annual review

Listing Report: MUR Reissue Date: 12/07/17 This report is subject to annual review CSI 06 12 16 PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics SECTION: Structural Panels Report Holder The Murus Company PO Box 220 Mansfield, PA 16933 Manufacturing Locations The

More information

All HUD Code Truss and Manufactured Housing Manufacturers

All HUD Code Truss and Manufactured Housing Manufacturers ENGINEERS PLANNERS CONSULTANTS 305 NORTH OAKLAND AVENUE P.O. BOX 490 NAPPANEE, INDIANA 46550 PHONE: 574-773-7975 WEB: WWW.NTAINC.COM FAX: 574-773-2260 All HUD Code Truss and Manufactured Housing Manufacturers

More information

WOOD I-JOIST AWARENESS GUIDE

WOOD I-JOIST AWARENESS GUIDE WOOD I-JOIST AWARENESS GUIDE American Wood Council Flange Web Flange American Forest & Paper Association WOOD I-JOIST AWARENESS GUIDE The American Wood Council is part of the wood products group of the

More information

Light Steel Framing ~ From Concept to Completion

Light Steel Framing ~ From Concept to Completion Light Steel Framing ~ From Concept to Completion Panelization made simple for the 21st century Automated Construction Equipment Automated Construction Equipment (ACE) is a leader in the design, development

More information

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012) Gaines Charter Township 8555 Kalamazoo Ave SE Caledonia MI 49316 PH: 616 698-6640 Fax: 616 698-2490 www.gainestownship.org Building Department Statement of Special Inspections Michigan Building Code 2012

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR THE TESTING AND ANALYSIS OF STEEL SHEET SHEATHING FOR WOOD AND COLD FORMED STEEL LIGHT

More information

Lamit Industries Nailbase Panels General Recommendations

Lamit Industries Nailbase Panels General Recommendations Lamit Industries Nailbase Panels General Recommendations Lamit Industries Nailbase Panels Sizes Lamit Industries Nailbase Panels are made in a variety of sizes; most commonly 4 x 8. Consult Lamit Industries

More information

AMERICAN INSTITUTE OF TIMBER CONSTRUCTION AITC

AMERICAN INSTITUTE OF TIMBER CONSTRUCTION AITC AMERICAN INSTITUTE OF TIMBER CONSTRUCTION 7012 South Revere Parkway Suite 140 Centennial, Colorado 80112 Telephone (303) 792-9559 http://www.aitc-glulam.org AITC 115-2009 STANDARD FOR FABRICATED STRUCTURAL

More information

Prepared for: American Frame Manufacturing Co Bristow Court, Unit B San Diego, CA Phone: Web:

Prepared for: American Frame Manufacturing Co Bristow Court, Unit B San Diego, CA Phone: Web: TESTING LISTING EVALUATION 257 EAST RANDOLPH STREET NAPPANEE, INDIANA 46550 PHONE: 574-773-7975 WWW.NTAINC.COM TESTLAB@NTAINC.COM FAX: 574-773-2260 NEGATIVE WIND PRESSURE TEST ON EXTERIOR SHEATHING FOR

More information

Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL Phone: GGTI (4484)

Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL Phone: GGTI (4484) Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL 33475 Phone: 888-984-GGTI (4484) E-mail:CPlaia@GGTISolutions.com Wind Mitigation Walt Leary 637 NE 12th Ter, Unit 7 Boynton Beach, FL 33435 September

More information

Christopher North Builders, INC.

Christopher North Builders, INC. Christopher North Builders, INC. 239-825-9155 Naples, Florida 34108 chrisnorthnaples@gmail.com Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation

More information

Christopher North Builders INC

Christopher North Builders INC Christopher North Builders INC Naples, Florida 239-825-9155 chrisnorthnaples@gmail.com Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation

More information

PFS Test Report TL-109

PFS Test Report TL-109 PFS Test Report TL-109 Laboratory Services Testing Research Consulting Model Code Qualifications Quality Assurance Design Calculations Sampling Witnessing ENGINEERED WOOD PRODUCTS MDF panels, I-Joists,

More information

DIVISION 06 WOOD, PLASTICS, AND COMPOSITES

DIVISION 06 WOOD, PLASTICS, AND COMPOSITES DIVISION 06 WOOD, PLASTICS, AND COMPOSITES 06 00 00 WOOD, PLASTICS, AND COMPOSITES 06 01 00 Maintenance of Wood, Plastics, and Composites 06 01 10 Maintenance of Rough Carpentry 06 01 10.71 Rough Carpentry

More information

Prepared for: American Frame Manufacturing Co Bristow Court, Unit B San Diego, CA Phone: Web:

Prepared for: American Frame Manufacturing Co Bristow Court, Unit B San Diego, CA Phone: Web: TESTING LISTING EVALUATION 257 EAST RANDOLPH STREET NAPPANEE, INDIANA 46550 PHONE: 574-773-7975 WWW.NTAINC.COM TESTLAB@NTAINC.COM FAX: 574-773-2260 NEGATIVE WIND PRESSURE TEST ON EXTERIOR SHEATHING FOR

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Owner Information Owner Name: Contact Person: Address:

More information

CLEAR CREEK COUNTY BUILDING DEPARTMENT REQUIREMENTS FOR A SINGLE FAMILY RESIDENCE

CLEAR CREEK COUNTY BUILDING DEPARTMENT REQUIREMENTS FOR A SINGLE FAMILY RESIDENCE CLEAR CREEK COUNTY BUILDING DEPARTMENT REQUIREMENTS FOR A SINGLE FAMILY RESIDENCE After all of your other permits have been issued and your construction plans and site plan have been approved by the other

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Owner Information Owner Name: Contact Person: Address:

More information

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2) Inspection of Fabricators (1704.2) Furnish inspection reports (1704.2.1) - Fabricators that have not been approved Provide a Certificate of Compliance (1704.2.2) - Approved Fabricators Steel Construction

More information

DATE:6/18/2013 INSPECTOR: ELEVATION

DATE:6/18/2013 INSPECTOR: ELEVATION DATE:6/18/2013 INSPECTOR: C ELEVATION DATE:6/18/2013 ROOF DECK ATTACHMENT ROOF TO WALL OPENING PROTECTION NA DOCUMENTS/ PERMITS, TITUSVILLE 32780 Permit #12-768 Applied: 5.14.12 Issued: 5.14.12 Final:

More information

ALTERNATE BUILDING MATERIALS/PRODUCTS APPROVAL REQUIREMENTS

ALTERNATE BUILDING MATERIALS/PRODUCTS APPROVAL REQUIREMENTS INFORMATION BULLETIN / PUBLIC BUILDING CODE REFERENCE NO.: LABC 104.2.6 and 202 Effective: 01-01-2017 DOCUMENT NO.: Revised: 02-04-2019 Previously Issued As: P/BC 2014-119 PURPOSE ALTERNATE BUILDING MATERIALS/PRODUCTS

More information

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address:

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address: SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division Permit Application #: Project Address: Purpose: To meet the requirements of City of Walnut Creek Municipal Code Section

More information

Owner Information. Inspection Date:

Owner Information. Inspection Date: Draft Proposed Near-Term Changes for OIR Review Applied Research Associates, F. Lavelle, 5/27/11 Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Inspection

More information

TECH BULLETIN. SIP No. Subject: Engineered Wood Lap Siding from Louisiana-Pacific. Date: August 2010 (Revised January 2015)

TECH BULLETIN. SIP No.   Subject: Engineered Wood Lap Siding from Louisiana-Pacific. Date: August 2010 (Revised January 2015) TECH BULLETIN SIP No. 2074 Subject: Engineered Wood Lap Siding from Louisiana-Pacific Date: August 2010 (Revised January 2015) Louisiana-Pacific, a leader in the manufacture of Engineered- Wood lap siding,

More information

Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL Phone: GGTI (4484)

Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL Phone: GGTI (4484) Go Green Thermal Imaging, LLC P.O. Box 1523 Hobe Sound, FL 33475 Phone: 888-984-GGTI (4484) E-mail:CPlaia@GGTISolutions.com Wind Mitigation Richard & Andrea Freedman 182 Eagle Dr. Jupiter, FL 33477 March

More information

Standard test method for tensile strength of chemicalresistant mortar, grouts, and monolithic surfacings

Standard test method for tensile strength of chemicalresistant mortar, grouts, and monolithic surfacings IAS Accreditation Number Company Name Address TL-274 1500 Brigantine Drive Coquitlam, BC V3K 7C1 Canada Ian Chang, Regional Quality Manager Contact Name Telephone 604-520-3321 Effective Date of Scope October

More information

STATEMENT OF SPECIAL INSPECTION FORM

STATEMENT OF SPECIAL INSPECTION FORM Project Title: Permit #: Project Address: STATEMENT OF SPECIAL INSPECTION FORM This Statement of Special Inspections is submitted in fulfillment of the requirements of CBC Sections 1704 and 1705. Special

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Inspection Date: Owner Information Owner Name: Address: Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Contact Person: Home Phone: City: Zip: Work

More information

MASTERFORMAT SPECIFICATION

MASTERFORMAT SPECIFICATION Contact: PFB Manufacturing, LLC Insulspan SIP Plant 9012 East US 223 Blissfield, MI, USA 49228-0026 Phone: 800.726.3510 Plasti-Fab Ltd. Head Office 100, 2886 Sunridge Way N.E. Calgary, AB Canada, T1Y 7H9

More information

SPECIAL INSPECTION AGREEMENT

SPECIAL INSPECTION AGREEMENT DEVELOPMENT SERVICES DEPARTMENT BUILDING AND SAFETY DIVISION 156 S. BROADWAY, SUITE 130 TURLOCK, CALIFORNIA 95380 PHONE 209-668-5560 FAX 209-668-5107 SPECIAL INSPECTION AGREEMENT PERMIT NUMBER: DATE: OWNER:

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 061600 - SHEATHING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

PROVIDING TODAY S WORLDWIDE BUILDING SOLUTIONS

PROVIDING TODAY S WORLDWIDE BUILDING SOLUTIONS PROVIDING TODAY S WORLDWIDE BUILDING SOLUTIONS Precision Foam Fabricators ( PFF ) is leading the worldwide movement for building with Structural Insulated Panels (SIPs). SIPs are the basic component to

More information

Metal Roof Certification & Listing Program. 1. Program Licensee: This Certification Report was used to qualify Florida Product Approval FL

Metal Roof Certification & Listing Program. 1. Program Licensee: This Certification Report was used to qualify Florida Product Approval FL 145 Limekiln Road, Suite 100B Issue Dated: 6/19/2018 New Cumberland, PA 17070 Revision Date: 6/19/2018 www.keystonecerts.com Expiration Date: 6/19/2023 Construction Specifications Institute (CSI) Category:

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: 12/07/2018 Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Owner Information Owner Name: The Oaks

More information

SCOPE OF ACCREDITATION

SCOPE OF ACCREDITATION Standards Council of Canada 600-55 Metcalfe Street Ottawa, ON K1P 6L5 Canada Conseil canadien des normes 55, rue Metcalfe, bureau 600 Ottawa, ON K1P 6L5 Canada SCOPE OF ACCREDITATION FPInnovations EVALUATION

More information

NRCC Guarded Hot Box Testing (ASTM C ) for Energy Efficiency of a Total Roof Assembly

NRCC Guarded Hot Box Testing (ASTM C ) for Energy Efficiency of a Total Roof Assembly Introduction 2001 Company, contracted NRCC/IRC to evaluate and determine both the thermal resistance and air leakage characteristics of five roofing specimens under controlled laboratory conditions. The

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Jul 16, 2012 Owner Information Owner Name: John Miller

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: 05/24/2017 Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Owner Information Owner Name: Banana Bay

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR STRUCTURAL STEEL APPROVED FABRICATOR INSPECTION PROGRAMS 1.0 PURPOSE EC 020-2014 (Adopted

More information

Standard test method for tensile strength of chemicalresistant mortar, grouts, and monolithic surfacings

Standard test method for tensile strength of chemicalresistant mortar, grouts, and monolithic surfacings IAS Accreditation Number Company Name Address TL-274 1500 Brigantine Drive Coquitlam, BC V3K 7C1 Canada Simon Knight, Operations Manager Contact Name Telephone 604-520-3321 Effective Date of Scope November

More information

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS 2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS HECO-6 GENERAL Pre-construction conference Preconstruction meeting Scheduled by SI with the Contractor, UBO, A/E, and relevant subs prior to commencement

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1780 Reissued 11/2017 This report is subject to renewal 11/2019. DIVISION: 06 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2182 Reissued 08/2018 This report is subject to renewal 06/2019. DIVISION: 06 00

More information

DRY CONSTRUCTION SYSTEMS

DRY CONSTRUCTION SYSTEMS DRY CONSTRUCTION SYSTEMS Adrienn LEPEL BUTE Dry construction systems Prefabricated elements assembly on site Minimal use of water dry construction systems Assembled partitions Suspended ceilings Raised

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES 1.0 INTRODUCTION INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR COMPOSITE STEEL SHEET AND NONCOMBUSTIBLE SHEATHING PANELS EC 012-2016

More information

TER No Use of Icynene Classic Plus Spray Polyurethane Foam (SPF) in Unvented Attics & Crawlspaces

TER No Use of Icynene Classic Plus Spray Polyurethane Foam (SPF) in Unvented Attics & Crawlspaces Use of Icynene Classic Plus Spray Polyurethane Foam (SPF) Icynene, Inc. 6747 Campobello Road Mississauga, Ontario, Canada L5N 2L7 jevans@icynene.com Icynene.com TER No. 1703-15 Issue Date: July 8, 2014

More information

ACCREDITATION CRITERIA FOR INSPECTION PROGRAMS FOR MANUFACTURERS OF METAL BUILDING SYSTEMS AC472. September 2018 Effective January 1, 2019 PREFACE

ACCREDITATION CRITERIA FOR INSPECTION PROGRAMS FOR MANUFACTURERS OF METAL BUILDING SYSTEMS AC472. September 2018 Effective January 1, 2019 PREFACE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 ACCREDITATION CRITERIA FOR INSPECTION PROGRAMS FOR MANUFACTURERS OF METAL BUILDING SYSTEMS September 2018 Effective January

More information

STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department

STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department 1 2 STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department 3 4 5 6 7 PROJECT INFORMATION: Project Name: Owner Name: Architect/Engineer Name: FORM PREPARED BY: Project Address:

More information

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708 Insurance Appraisals Reserve Studies Wind Mitigation COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc. 401 150th Avenue Madeira Beach, FL 33708 As

More information

INSPECTION GUIDELINES: STRUCTURAL INSULATED PANELS (SIPs)

INSPECTION GUIDELINES: STRUCTURAL INSULATED PANELS (SIPs) Structural Insulated Panels Page 1 of 7 Revision Date: 05/22/2017 DEVELOPMENT SERVICES BUILDING INSPECTION INSPECTION GUIDELINES: STRUCTURAL INSULATED PANELS (SIPs) INSPECTION CODE: 111, 204, 216 SCOPE:

More information

STATEMENT OF SPECIAL INSPECTIONS - MBC-2012

STATEMENT OF SPECIAL INSPECTIONS - MBC-2012 1 2 STATEMENT OF SPECIAL INSPECTIONS - MBC-2012 CHARTER TOWNSHIP OF WEST BLOOMFIELD BUILDING DEPARTMENT 3 4 5 6 7 8 9 10 11 12 13 PROJECT INFORMATION: Project Name: Owner Name: Architect/Engineer Name:

More information

1. Asphalt / Fiberglass Shingle / / 2. Concrete / Clay Tile 05_/_01 /_ Metal / / 4. Built Up / / 5. Membrane / / 6.

1. Asphalt / Fiberglass Shingle / / 2. Concrete / Clay Tile 05_/_01 /_ Metal / / 4. Built Up / / 5. Membrane / / 6. Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation with the insurance policy Inspection Date: 14-Aug-14 Owner Information Owner Name: Contact Person: Brett

More information

BENCHMARK HOLDINGS L.L.C WEST 5 TH AVENUE EUGENE, OREGON 97402

BENCHMARK HOLDINGS L.L.C WEST 5 TH AVENUE EUGENE, OREGON 97402 This is to attest that BENCHMARK HOLDINGS L.L.C. 2710 WEST 5 TH AVENUE EUGENE, OREGON 97402 Testing Laboratory TL-280 has met the requirements of AC89, IAS Accreditation Criteria for Testing Laboratories,

More information

Approved Manufacturing Location Alpha Systems, Inc Beck Drive Elkhart, IN 46516

Approved Manufacturing Location Alpha Systems, Inc Beck Drive Elkhart, IN 46516 Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Product Evaluation Report represents a product that Pei ES has Evaluated. This product has a Product

More information

PICKENS COUNTY BUILDING CODES SPECIAL INSPECTION PROCEDURE IBC CHAPTER EDITION

PICKENS COUNTY BUILDING CODES SPECIAL INSPECTION PROCEDURE IBC CHAPTER EDITION PICKENS COUNTY BUILDING CODES SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17 2012 EDITION When Required All projects that require a SC licensed Architect or Engineer per SC Architectural and Engineering registration

More information

The National Air Barrier Association. Quality Assurance for the Air Barrier Industry

The National Air Barrier Association. Quality Assurance for the Air Barrier Industry The National Air Barrier Association Quality Assurance for the Air Barrier Industry Table of Contents 2. What and who is NABA? 3. What are the objectives of the association? 4. How is the association managed?

More information

Standard test method for compressive strength of cylindrical concrete specimens. Standard test method for flexural strength of hydrauliccement

Standard test method for compressive strength of cylindrical concrete specimens. Standard test method for flexural strength of hydrauliccement IAS Accreditation Number Company Name Address TL-228 Specialized Testing, Inc. 10600 Pioneer Boulevard, Suite G Santa Fe Springs, California 90670 Martin Mejia, Technical Manager Contact Name Telephone

More information

ASTM E1918: standard test method for measuring solar reflectance of horizontal and lowsloped surfaces in the field

ASTM E1918: standard test method for measuring solar reflectance of horizontal and lowsloped surfaces in the field IAS Accreditation Number Company Name Address TL-264 2524 E Jensen Ave. Fresno, CA 93706 Leaton Kirk, Director - Regional Operations Contact Name Telephone (559) 233-8705 Effective Date of Scope December

More information

Metal Roof Certification & Listing Program

Metal Roof Certification & Listing Program 145 Limekiln Road, Suite 100B Issue Dated: 10/27/2017 New Cumberland, PA 17070 Revision Date: 10/27/2017 www.keystonecerts.com Expiration Date: 10/27/2022 Construction Specifications Institute (CSI) Category:

More information

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board 1. Scope 1.1 This standard defines the minimum prescriptive quality and performance requirements for Fiberreinforced Magnesium Cement Board products intended for use in buildings in North America. For

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

USG TESTING SERVICES FIRE STRUCTURAL ACOUSTICAL ANALYTICAL. usg.com/cictesting

USG TESTING SERVICES FIRE STRUCTURAL ACOUSTICAL ANALYTICAL. usg.com/cictesting USG TESTING SERVICES FIRE STRUCTURAL ACOUSTICAL ANALYTICAL usg.com/cictesting INNOVATION For more than a century, USG has been bringing innovation to the forefront of the building industry. During this

More information

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised May 30, 2013

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised May 30, 2013 Murphy Laminated Veneer Lumber PR-L283 Murphy Engineered Wood Division Revised May 30, 2013 Product: 2250F b -1.5E, 2600F b -1.7E, 2750F b -1.8E, 2850F b -1.9E, 2950F b -2.0E, 3100F b -2.0E, and 3100F

More information

Special Inspections for Wood Construction BCD710 Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council

Special Inspections for Wood Construction BCD710 Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council Special Inspections for Wood Construction BCD710 Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council Copyright Materials This presentation is protected by US and International

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy Inspection Date: 08/12/2011 Owner Information Owner Name: Steve Owner Contact Person: Joe Contact Address:

More information

Statement of Special Inspections 2013 CBC

Statement of Special Inspections 2013 CBC BUILDIG & SAFET DIVISIO 2729 Prospect Park Drive Rancho Cordova, CA 95670 Phone: (916) 851-8760 Fax: (916) 851-8762 Statement of Special Inspections 2013 CBC PERMIT #: PROJECT ADDRESS: This Statement of

More information

BASF HP+ Wall XR Series Limit States TER No

BASF HP+ Wall XR Series Limit States TER No BASF HP+ Wall XR Series Limit States TER No. 1506-01 BASF, Inc. 100 Park Ave Florham Park, NJ 07932-1089 973-245-6000 basf.com Issue Date: October 21, 2015 Updated: March 27, 2019 Subject to Renewal :

More information

International Building Code/International Residential Code Inspection & Quality Assurance Requirements for Metal Plate Connected Wood Trusses

International Building Code/International Residential Code Inspection & Quality Assurance Requirements for Metal Plate Connected Wood Trusses International Building Code/International Residential Code Inspection & Quality Assurance Requirements for Metal Plate Connected Wood Trusses Released May 7, 2008 Introduction: WTCA has developed this

More information

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company PRINCE WILLIAM COUNTY Department Development Services Building Development Division STATEMENT OF SPECIAL INSPECTIONS (Building/Other Structures other than Retaining Walls) Version 2015-12-31 Building Permit

More information

Page Roof Covering Type: Permit Application Date FBC or MDC Product Approval #

Page Roof Covering Type: Permit Application Date FBC or MDC Product Approval # Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: 1/5/2013 Owner Information Owner Name: Sinha Contact

More information

BENCHMARK HOLDINGS, L.L.C. BENCHMARK INTERNATIONAL, L.L.C WEST 5 TH AVENUE EUGENE, OREGON 97402

BENCHMARK HOLDINGS, L.L.C. BENCHMARK INTERNATIONAL, L.L.C WEST 5 TH AVENUE EUGENE, OREGON 97402 This is to attest that BENCHMARK HOLDINGS, L.L.C. BENCHMARK INTERNATIONAL, L.L.C. 2710 WEST 5 TH AVENUE EUGENE, OREGON 97402 Testing Laboratory TL- 280 has met the requirements of AC89, IAS Accreditation

More information

Building Department Informational Handout

Building Department Informational Handout City of Sonoma Building Department Informational Handout Statement of Special Inspections Handout No: 7 Revised 1/12/2017 Project Name: Project Address: For building permit applications of projects requiring

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Inspection Date: Owner Information Owner Name: Address: Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Contact Person: Home Phone: City: Zip: Work

More information

Introduction: Issue: Analysis/Conclusion:

Introduction: Issue: Analysis/Conclusion: Special Inspection Requirements for Buildings Falling under the Jurisdiction of the California Division of the State Architect and the 2007 California Building Code Released May 7, 2008 Introduction: WTCA

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Uniform Mitigation Verification Inspection Form Maintain a copy of this form and any documentation provided with the insurance policy Inspection Date: 04/01/2015 Owner Information Owner Name: JACK AND

More information

HUD Green Mortgage Insurance Premium (MIP) Reduction Q1 2017

HUD Green Mortgage Insurance Premium (MIP) Reduction Q1 2017 The HUD MIP Reduction program accepts nine national and regional green building standards including Energy Star High Rise or Home, NGBS, LEED, Green Point Rated New Home Multifamily, Passive House, Enterprise

More information

SECTION 7307 CONCRETE/ CLAY TILE, METAL, SLATE AND ASPHALT COMPOSITION SELF-ADHERED/ PEEL & STICK ROOF UNDERLAYMENT

SECTION 7307 CONCRETE/ CLAY TILE, METAL, SLATE AND ASPHALT COMPOSITION SELF-ADHERED/ PEEL & STICK ROOF UNDERLAYMENT Part 1 General 1.01 Summary A. Section Includes: 1. Self-adhered peel & stick roof underlayment system. 2. Provide and install underlayment in compliance with manufacturer s specified installation requirements.

More information

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 International Beams Inc. 2010 Boul. St-Elzear Quest Laval, QC H7L 3N4 CANADA This report is for the exclusive use of Intertek

More information

SPECIAL INSPECTION AGREEMENT FORM

SPECIAL INSPECTION AGREEMENT FORM CITY OF TRACY DEVELOPMENT & ENGINEERING SERVICES 333 CIVIC CENTER PLAZA, TRACY, CA 95376 P :( 209) 831-6400 F :( 209) 831-6439 http://www.ci.tracy.ca.us SPECIAL INSPECTION AGREEMENT FORM Prior to issuance

More information

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018 HUBER ENGINEERED WOODS ZIP SYSTEM R-SHEATHING CSI Section: 06 12 00 Structural Panels 06 16 00 Sheathing 1.0 RECOGNITION ZIP System R-Sheathing panels, manufactured by Huber Engineered Woods, LLC, were

More information

APA Report T2012L-16

APA Report T2012L-16 APA Report T2012L-16 Narrow Wall Bracing by Edward L. Keith, P.E. Technical Services Division August 8, 2012 Accredited by TL-215 REPRESENTING THE ENGINEERED WOOD INDUSTRY 7011 South 19th Street Tacoma,

More information

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Inspection Date: Owner Information Owner Name: Address: Uniform Mitigation Verification Inspection Form Maintain a copy of this form with the insurance policy Contact Person: City: Jupiter Zip: 33458 Work

More information

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831) County of Santa Cruz PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA 95060 (831) 4542580 FA: (831) 4542131 STATEMENT OF SPECIAL INSPECTIONS California Building Code 1704.3 Prior to issuance,

More information

Advanced Structures and Composites Center, University of Maine 35 Flagstaff Road Orono, Maine Benjamin Herzog, Quality Manager

Advanced Structures and Composites Center, University of Maine 35 Flagstaff Road Orono, Maine Benjamin Herzog, Quality Manager IAS Accreditation Number Company Name Address Contact Name Telephone (207) 581-2360 Effective Date of Scope March 27, 2017 Accreditation Standard ISO/IEC 17025:2005 TL-255 Composites Center, University

More information

Versetta Stone Panelized Stone Veneer Applications Over Continuous Insulation. TER No Boral Stone Products LLC

Versetta Stone Panelized Stone Veneer Applications Over Continuous Insulation. TER No Boral Stone Products LLC Applications Over Continuous Insulation TER No. 1212-01 Boral Stone Products LLC 200 Mansell Court East, Suite 310 Roswell, GA 30076 419-318-5345 949-341-8890 (fax) chris.hines@boral.com versettastone.com

More information

A. Provide and install a factory made, wood framed, storage building. B. Building Construction Type: IBC Type V-B Wood Frame.

A. Provide and install a factory made, wood framed, storage building. B. Building Construction Type: IBC Type V-B Wood Frame. Farmington, Missouri Project Number M1801-0l PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide and install a factory made, wood framed, storage building. B. Building Construction Type: IBC Type V-B Wood

More information

Report on Commercial and Residential Carpentry and Steel Framing

Report on Commercial and Residential Carpentry and Steel Framing Workers Compensation Insurance Rating Bureau of California Workers Compensation Insurance Rating Bureau of California Report on Commercial and Residential Carpentry and Steel Framing Excerpt from the WCIRB

More information

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address:

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address: SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION Permit Application #: Project Address: Purpose: To meet the requirements of CBC Section 1704.3 this form may be used as a statement

More information

Stark Truss Company, Inc. Revised December 14, 2018

Stark Truss Company, Inc. Revised December 14, 2018 Fire-Rated Assemblies PR-S223 Stark Truss Company, Inc. Revised December 14, 2018 Products: SI-40, SI-60, and SI-80 Prefabricated Wood I-Joists Stark Truss Company, Inc. 8655 Chestnut Ridge Road, N.W.

More information

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1474 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 06 00

More information

High Performance Walls:

High Performance Walls: High Performance Walls: Advanced Framing Walls Systems and Insulated Headers Karyn Beebe, PE, LEED AP APA The Engineered Wood Association Quality Services Division Technical Services Division Field Services

More information