BENCHMARK Evolution Axis

Size: px
Start display at page:

Download "BENCHMARK Evolution Axis"

Transcription

1 Sheet List EVO VT 00 B

2 DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL DESIGN SUCTION LOAD Vertical Joints EVO VT 01 B

3 HORIZONTAL SHEETING RAIL TYPICAL LAYOUT FOR VERTICALLY FIXED PANELS MAIN STANCHION (BEHIND) INSULATED PANELS VERTICAL POST COLD ROLLED CHANNEL OR SIMILAR HORIZONTAL SHEETING RAIL E/BEAM (UB OR SIMILAR) VERTICAL POST COLD ROLLED CHANNEL OR SIMILAR MAIN STANCHION STEELWORK BEARING WIDTH TO SUIT PANEL HORIZONTAL SHEETING RAIL CONTINUOUS RSA OR SIMILAR STEELWORK BEARING WIDTH TO SUIT PANEL MAIN FRAME CENTRES SHEETING RAIL SUPPORT SYSTEM (IF REQUIRED) Vertical Sheeting Rails EVO VT 02 B

4 CONTINUOUS RUN OF 6X4 BUTYL CONTINUOUS LEDGER ANGLE CONTINUOUS RUN OF 6X4 BUTYL INTERNAL CLOSER FLASHING CONTINUOUS BASE SUPPORT ANGLE CUT END COVER FLASHING SEALED WITH 6X4MM BUTYL BASE DRIP FLASHING CONTINUOUS RUN OF SILICONE FOAM SEAL GUN GRADE SILICONE ACROSS JOIN, BACK SEALED WITH 6X4MM BUTYL GUN GRADE SILICONE ACROSS JOIN, BACK SEALED WITH 6X4MM BUTYL CUT END COVER FLASHING SEALED WITH 6 X4MM BUTYL BASE DRIP FLASHING CONTINUOUS RUN OF SILICONE CONTINUOUS LEDGER ANGLE PEF ROD SEALED WITH SILICONE Base Detail EVO VT 03 B

5 CORNER FLASHING WITH 150MM SEALED OVERLAP OR BUTT-STRAPS. SEALED WITH CONTINUOUS RUN OF 6X4 BUTYL FILL GAPS WITH FR FOAM FILLER INTERNAL FLASHING WITH 150MM SEALED OVERLAP OR BUTT-STRAPS. SEALED WITH CONTINUOUS RUN OF 6X4 BUTYL Vertical External Corner EVO VT 04 B

6 INTERNAL CORNER FLASHING WITH 150MM SEALED OVERLAP OR BUTT-STRAPS. SEALED WITH CONTINUOUS RUN OF 6X4MM BUTYL FILL GAPS WITH FR FOAM FILLER INTERNAL FLASHING SEALED WITH CONTINUOUS RUN OF 6X4MM BUTYL Vertical Internal Corner EVO VT 05 B

7 KINGSPAN RECESSED WASHER PEF ROD SEALED WITH SILICONE END FLASHING WITH 150MM SEALED OVERLAP. SEALED TO PANEL WITH CONTINUOUS RUN OF 6X4MM BUTYL AXIS INSULATED WALL PANEL VERTICALLY LAID FILL GAPS WITH FR FOAM FILLER CONTINUOUS SUPPORT ANGLE CONTINUOUS RUN OF SILICONE END FLASHING WITH 150MM SEALED OVERLAP. SEALED TO PANEL WITH CONTINUOUS RUN OF 6X4MM BUTYL PEF ROD SEALED WITH SILICONE PANEL VERTICALLY LAID FILL GAPS WITH FR FOAM FILLER CONTINUOUS SUPPORT ANGLE CONTINUOUS RUN OF SILICONE Abutment to Masonry Wall - 1 EVO VT 06 B

8 STEEL END FLASHING SEALED TO PANEL WITH 6X4MM BUTYL DPC LAYER BETWEEN TOP OF CONCRETE AND UNDERSIDE OF PANEL AXIS INSULATED WALL PANEL VERTICALLY LAID CONTINUOUS RUN OF SILICONE CONTINUOUS SUPPORT ANGLE CONTINUOUS RUN OF SILICONE END FLASHING WITH 150MM SEALED OVERLAP. SEALED TO PANEL WITH CONTINUOUS RUN OF 6X4MM BUTYL DPC LAYER BETWEEN TOP OF CONCRETE AND UNDERSIDE OF PANEL CONTINUOUS RUN OF SILICONE CONTINUOUS SUPPORT ANGLE CONTINUOUS RUN OF SILICONE Abutment to Masonry Wall - 2 EVO VT 07 B

9 CLOSED CELL FOAM EAVES FILLER BLOCK SITE APPLIED SILICONE EAVES SEAL PRESSED STEEL GUTTER 75MM EAVES OVERHANG GUTTER BRACKET ATTACHED TO FASCIA BOARD FIXED TO PURLINS FILL GAPS WITH FR FOAM FILLER INTERNAL FLASHING Eaves Gutter EVO VT 08 B

10 75MM EAVES OVERHANG CLOSED CELL FOAM EAVES FILLER BLOCK FIXING AT CROWN ADDITIONAL TREATMENT REQUIRED IF UNDERSIDE OF PANEL IS EXPOSED KINGSPAN KS1000 RW ROOFING PANEL SITE APPLIED SILICONE EAVES SEAL INTERNAL FLASHING CONTINUOUS RUN OF 6X4MM BUTYL GUTTER BRACKET ATTACHED TO FASCIA BOARD FIXED TO PURLINS PRESSED STEEL GUTTER FILL GAPS WITH FR FOAM FILLER EXTERNAL FLASHING FLASHING TO SUIT EXT MATERIAL. CUT AROUND STRUCTURE AS NECESSARY SOFFIT FLASHING SEALED WITH 6X4MM BUTYL FLASHING TO SUIT LINER MATERIAL. CUT AROUND STRUCTURE AS NECESSARY FOAM AWP FILLER SEALED ACROSS JOIN WITH SILICONE Overhang Eaves Gutter EVO VT 09 B

11 PARAPET FLASHING SEALED WITH 6X4MM BUTYL PIR OR TIMBER INFILL BLOCK FOAM FILLER SEALED ACROSS JOIN WITH SILICONE 75 SITE APPLIED SILICONE EAVES SEAL FIXING AT CROWN EDGE FLASHING 300MM MAX AIR SEAL 6X4MM BUTYL KINGSPAN MEMBRANE GUTTER STRUCTURAL MEMBER Boundary Gutter EVO VT 10 B

12 VERGE FLASHING WITH 150MM SEALED OVERLAP OR BUTT-STRAPS. SEALED TO WALL PANEL WITH 6X4MM BUTYL DIRECTION OF LAY CONTINUOUS RUN OF 6X4MM BUTYL FILL GAPS WITH FR FOAM FILLER FOAM EVO FILLER SEALED ACROSS JOIN WITH SILICONE GALV CLEADER ANGLE BY STEEL CONTRACTOR ALTERNATIVE FLASHING DETAIL DIRECTION OF LAY VERGE FLASHING WITH 150MM SEALED OVERLAP OR BUTT-STRAPS. SEALED TO WALL PANEL WITH 6X4 BUTYL "Z" FLASHING WITH CONTINUOUS RUNS OF 6X4 BUTYL FILL GAPS WITH FR FOAM FILLER Verge 1 EVO VT 11 B

13 CONTINUOUS RUN OF 6X4MM BUTYL VERGE FLASHING WITH 150MM SEALED OVERLAP OR BUTT-STRAPS DIRECTION OF LAY VERGE FLASHING WITH 150MM SEALED OVERLAP OR BUTT-STRAPS "Z" FLASHING WITH CONTINUOUS RUNS OF 6X4MM BUTYL DIRECTION OF LAY ALTERNATIVE FLASHING DETAIL CONTINUOUS RUN OF 6X4MM BUTYL GALV CLEADER ANGLE BY STEEL CONTRACTOR FOAM EVO FILLER SEALED ACROSS JOIN WITH SILICONE Verge 2 EVO VT 12 B

14 AXIS INSULATED WALL CONTINUOUS LEDGER ANGLE (BY OTHERS) CUT EDGE PROTECTION FLASHING APRON FLASHING KINGSPAN KS1000 RW ROOFING PANEL FOAM RIDGE FILLER SEALED TOP & BOTTOM WITH NON SETTING FIXING AT PAN FILL GAPS WITH FR FOAM FILLER INTERNAL FLASHING Skillion Detail EVO VT 13 B

15 AXIS INSULATED WALL PANEL VERTICALLY LAID CONTINUOUS LEDGER ANGLE (BY OTHERS) GUN GRADE SILICONE ACROSS JOIN, BACK SEALED WITH 6X4MM BUTYL FIRE RATED CANISTER INSULATION APPLIED AS PANEL IS PLACED CONTINUOUS GALV SUPPORT ANGLE CUT END COVER FLASHING DRIP FLASHING SEALED TO FACE OF PANEL WITH 6X4MM BUTYL EVO JOINT FILLER AND SILICONE TO MALE JOINT VERTICAL STACK JOINT AXIS INSULATED WALL PANEL VERTICALLY LAID GUN GRADE SILICONE ACROSS JOIN, BACK SEALED WITH 6X4MM BUTYL CUT END COVER FLASHING CONTINUOUS LEDGER ANGLE (BY OTHERS) FIRE RATED CANISTER INSULATION CONTINUOUS GALV SUPPORT ANGLE 6 MIN DRIP FLASHING SEALED TO FACE OF PANEL WITH 6X4MM BUTYL AXIS INSULATED WALL PANEL HORIZONTALLY LAID VERTICAL TO HORIZONTAL JOINT Horizontal & Vertical Stack Joint Detail EVO VT 14 B

16 PIR BOARD AND FIRE RATED CANISTER APPLIED INSULATION * RECESSED WASHER INTERNAL FINISH TO ARCHITECT'S DESIGN WINDOW BY OTHERS* BENCHMARK EVOLUTION AXIS INSULATED WALL PANEL HORIZONTALLY LAID. THICKNESS TO ATTAIN R VALUE WEATHER SEAL BY WINDOW INSTALLER* JAMB FLASHING WITH CONTINUOUS RUN OF 6X4MM BUTYL. THICKNESS TO ATTAIN R VALUE AIR SEAL - CONTINUOUS BEAD OF GUN GRADE EXTERNAL WINDOW HEAD FLASHINGS PIR BOARD INSULATION* STRUCTURAL FRAMING SYSTEM* PIR BOARD INSULATION* INTERNAL FINISH TO ARCHITECT'S DESIGN WEATHER SEAL BY WINDOW INSTALLER* WINDOW BY OTHERS* WEATHER SEAL BY WINDOW INSTALLER* PIR BOARD AND FIRE RATED CANISTER APPLIED INSULATION * AIR SEAL - CONTINUOUS BEAD OF GUN GRADE EXTERNAL WINDOW SILL FLASHINGS WINDOW FIXED WITH FERRULES* INTERNAL FINISH TO ARCHITECT'S DESIGN NOTE: ITEMS MARKED * ARE NOT SUPPLIED BY KINGSPAN 9 X 3MM BUTYL MASTIC SEAL Evo Vertically Laid - Recessed Window EVO VT 15 B

17 INTERNAL FINISH TO ARCHITECT'S DESIGN PIR BOARD AND FIRE RATED CANISTER APPLIED INSULATION * WINDOW BY OTHERS* WEATHER SEAL BY WINDOW INSTALLER* AXIS INSULATED WALL PANEL VERTICALLY LAID. THICKNESS TO ATTAIN R VALUE KINGSPAN PANEL BEARER JAMB FLASHING WITH CONTINUOUS RUN OF 6X4MM BUTYL Evo Vertically Laid - Recessed Window (Cont.) EVO VT 16 B

18 CONTINUOUS LEDGER ANGLE (BY OTHERS) CUT END COVER FLASHING HEAD FLASHING SEALED WITH 6X4MM BUTYL DOOR UNIT BY OTHERS AXIS INSULATED WALL PANEL VERTICALLY LAID. THICKNESS TO ATTAIN R VALUE GUN GRADE SILICONE ACROSS JOIN, BACK SEALED WITH 6X4MM BUTYL DOOR SUPPORT FRAME PF BACKING ROD WITH SILICONE. BY DOOR INSTALLER SOFFIT FLASHING DOOR JAMB SUPPORT FRAME DOOR UNIT BY OTHERS DOOR JAMB SUPPORT FRAME PF BACKING ROD WITH SILICONE. BY DOOR INSTALLER JAMB FLASHING SEALED WITH 6X4MM BUTYL. THICKNESS TO ATTAIN R VALUE KINGSPAN RECESSED WASHER Personnel Door Detail EVO VT 17 B

19 BENCHMARK EVOLUTION AXIS INSULATED WALL PANEL VERTICALLY LAID CUT END COVER FLASHING SOFFIT FLASHING HEAD FLASHING SEALED WITH 6X4 BUTYL SEE DOOR MANUFACTURERS DETAILS FOR HEIGHT REQUIRED ROLLER DRUM GUN GRADE SILICONE ACROSS JOIN, BACK SEALED WITH 6X4MM BUTYL DOOR GUIDE SUPPORTED BY MAIN STRUCTURE DOOR HEAD SUPPORT FRAME PF BACKING ROD WITH SILICONE. BY DOOR INSTALLER CONTINUOUS LEDGER ANGLE VARIABLE SLOPE DOOR GUIDE BY OTHERS DOOR BY OTHERS STRUCTURAL DOOR JAMB BY OTHERS 2 PART JAMB FLASHING SEALED WITH 6X4MM BUTYL Overhead Door Detail EVO VT 18 B

20 CUT END COVER FLASHING GUN GRADE SILICONE ACROSS JOIN, BACK SEALED WITH 6X4MM BUTYL 6 MIN LOUVRE SUPPORT FRAME HEAD FLASHING SEALED WITH 6X4 BUTYL CONTINUOUS LEDGER ANGLE SOFFIT FLASHING SILICONE TO PERIMETER SILL FLASHING FILLER SEALED TOP & BOTTOM WITH GUN GRADE. SILICONE ACROSS JOINT Louvre Detail (Vertical Section) EVO VT 19 B

21 (OPTION A) LOUVRE SUPPORT FRAME LOUVRE UNIT SILICONE (OPTION B) LOUVRE SUPPORT FRAME LOUVRE UNIT SILICONE JAMB FLASHING SEALED WITH 6X4MM BUTYL Louvre Detail (Horizontal Section) EVO VT 20 B

22 "DEKTITE" FLEXIBLE PIPE FLASHING OR SIMILAR TO SUIT CONDITIONS INTERNAL COVER FLASHING SEALED WITH 6X4MM BUTYL PIPE/DUCTING STANDARD TEMPERATURE "DEKTITE" FLEXIBLE PIPE FLASHING OR SIMILAR TO SUIT CONDITIONS (TO 115 MAX) PIPE/DUCTING SITE APPLIED NON-COMBUSTIBLE INSULATION HIGH TEMPERATURE MAX UNSUPPORTED CIRCULAR PENETRATION - 300MM INTERNAL COVER FLASHING SEALED WITH 6X4MM BUTYL HOLE SITE CUT TO ACCOMMODATE PIPE/DUCTING ETC. LINE WITH GALVANISED SOAKER GRP INSITU WEATHERING SYSTEM BONDED TO PANELS EXTERNAL SHEET, COLOUR TO MATCH EXTERNAL PANEL INTERNAL COVER FLASHING SEALED WITH 6X4MM BUTYL SITE APPLIED NON- COMBUSTIBLE INSULATION PIPE/DUCTING ALTERNATIVE STANDARD TEMPERATURE HOLE SITE CUT TO ACCOMMODATE PIPE/DUCTING ETC. LINE WITH GALVANISED SOAKER AXIS INSULATED WALL PANEL VERTICALLY LAID NOTE: MAXIMUM CIRCULAR HOLE SIZE TO BE 300MM. PENETRATIONS GREATER WILL REQUIRE ADDITIONAL SUPPORTING STEEL. FLEXIBLE PIPE FLASHING PROVIDES A COMPLETELY WEATHERPROOF SOLUTION FOR PIPE OPENINGS THROUGH A WALL. THEY CAN BE MOLDED BY HAND TO SUIT THE SHEET PROFILE, BEDDED IN WEATHER & FIXED TO THE WALL SHEET. Penetration Detail EVO VT 21 B

Architectural Wall Panels (AWP) KS CX/EB/FL/FL-S/ MR/MM/PL/WV KS1000 CW/LV/TL

Architectural Wall Panels (AWP) KS CX/EB/FL/FL-S/ MR/MM/PL/WV KS1000 CW/LV/TL Architectural Wall Panels (AWP) KS600-1000 CX/EB/FL/FL-S/ MR/MM/PL/WV Insulated Roof & Wall Panels Installation Guide November 2017 Architectural Wall Panel Primary / Main fastener Non-setting gun-grade

More information

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation Hip Detail Hip Detail STANDARD Mineral fibre insulation ENHANCED Hip flashing with 150mm sealed butt straps Panels site cut to suit rake angle Apex dam (Ref: LP1/A) Rake cut profiled filler sealed top

More information

Promistyl 3005T - roofing

Promistyl 3005T - roofing Metal Cladding Panel reference Arval Globalroof Promistyl 3005T ribbed face fix composite fire rated roofing panels Arval Promistyl 3005T Manufacturer ArcelorMittal Lammerdries 82440 Geel Belgium web site:

More information

Kingspan Topdek KS1000 TD Insulated Single Ply Roofdeck Installation Guide

Kingspan Topdek KS1000 TD Insulated Single Ply Roofdeck Installation Guide Insulated Roof & Wall Panels UK & Republic of Ireland Topdek KS1000 TD Insulated Single Ply Roofdeck Installation Guide June 2018 Topdek (KS1000 TD) Components Topdek (KS1000 TD) 514cw 50mm Wide Acrylic

More information

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV

More information

europanel installation guide horizontally laid panel

europanel installation guide horizontally laid panel europanel installation guide horizontally laid panel A 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing face is consistent

More information

KARRIER PANEL - BRICK

KARRIER PANEL - BRICK KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK

More information

rockspan installation guide horizontally laid panel

rockspan installation guide horizontally laid panel rockspan installation guide horizontally laid panel A 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing face is consistent

More information

Kingspan rethinking the limits of design

Kingspan rethinking the limits of design Kingspan rethinking the limits of design Wall façade systems design guide Publication date December 2007 Kingspan rethinking the limits of design Kingspan insulated wall façade design guide 2 Contents

More information

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity) September 2014 NU-WALL EXTRUDED ALUMINIUM CLADDING Installation Specifications Vertical orientation (over cavity) 1. NW-V001C; Cavity batten layout 2. NW-V002C; Battening options 3. NW-V002C; Battening

More information

Trimform for panels, purlins & gutters. No obligation consultation

Trimform for panels, purlins & gutters. No obligation consultation Trimform for panels, purlins & gutters. No obligation consultation Vers 1:02/2016 Trimform Insulated Panels Trimform insulated panels consist of two coated steel profile bonded to a core of PIR insulation;

More information

Trapezoidal. Vertically Laid Insulated Wall Systems. Product Data 527. Model Specifications 531. Fastener Selection 541. Construction Details 543

Trapezoidal. Vertically Laid Insulated Wall Systems. Product Data 527. Model Specifications 531. Fastener Selection 541. Construction Details 543 Product Data 527 Model Specifications 531 Fastener Selection 541 Construction Details 543 Panel Dimensions 543 Fastener Locations 543 End & Side Lap 544 Drip 545 External Corner 546 Internal Corner 547

More information

Section 10 Ward Wall Horizontal - DW Range Flat Stucco, T&G Rib, Shadow Rib, Mini Rib

Section 10 Ward Wall Horizontal - DW Range Flat Stucco, T&G Rib, Shadow Rib, Mini Rib Section 10 Ward Wall Horizontal - DW Range Flat Stucco, T&G Rib, Shadow Rib, Mini Rib Panel Dimensions 2-3 Product Data Sheets 4-6 Load Tables 7 Typical Layout for Horizontal Fixed Panels 8-9 Panel Joints

More information

Section 3 Ward Roof Trapezoidal IP1000

Section 3 Ward Roof Trapezoidal IP1000 Section 3 Ward Roof Trapezoidal IP1000 Panel Dimensions 2 Product Data Sheets 3-5 Load Tables 6 Recommended Fastener Locations 7 End Lap Detail 8 Side Lap Detail 9 Ridge Detail 10-11 Verge Detail 12-15,

More information

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing

More information

WeatherSmart Air Barrier Installation Guide

WeatherSmart Air Barrier Installation Guide WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material

More information

Guidance document January 2015

Guidance document January 2015 Guidance document January 2015 A GUIDE TO SITE INSTALLATION OF INSULATED ROOF PANELS This bulletin introduces the reader to key issues that need to be addressed for the installation of an insulated roof

More information

Insulated Roof & Wall Panels

Insulated Roof & Wall Panels Insulated Roof & Wall Panels INSULATED ROOF AND WALL PANELS Contents Introduction 3 Accessories 5 Design considerations 6-8 Product Performance 9-15 Design Details AS35 Roof & Wall Panels 16-27 Design

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/ General conditions. TYPES OF COVERING 115A SINGLE LAYER REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING warm roofing system

More information

Insulated Roof & Wall Panels. KS1000 RT Roof Tile

Insulated Roof & Wall Panels. KS1000 RT Roof Tile Insulated Roof & Wall Panels KS1000 RT Roof Tile KS1000 RT Roof Tile 2 Contents Introduction 4 Applications 6 Product Data 10 Construction Details 16 3 Introduction Kingspan Roof Tile offers traditional

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation

More information

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED ConquererTM Panel Products Introduction ConquerorTM International Ltd is New Zealand s only manufacturer

More information

rainspan installation guide horizontally laid panel

rainspan installation guide horizontally laid panel rainspan installation guide horizontally laid panel standard details A C 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing

More information

0331 Brick and block construction

0331 Brick and block construction 0331 BRICK AND BLOCK CONSTRUCTION 1 GENERAL 1.1 STANDARDS Materials and construction: To AS 4773.1 and AS 4773.2. 2 PRODUCTS 2.1 DURABILITY Exposure environment: [complete/delete] Exposure locations: To

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal

More information

AS35 INSULATED PANELS. Insulated Roof & Wall Panels

AS35 INSULATED PANELS. Insulated Roof & Wall Panels AS35 INSULATED PANELS Insulated Roof & Wall Panels INSULATED ROOF AND WALL PANELS Contents Introduction 3 Accessories 5 Design considerations 6-8 Product Performance 9-15 Design Details AS35 Roof & Wall

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08

More information

Insulated Roof & Wall Panels. KS1000 TD Data Sheet. Topdek Single Ply Roof Deck. Insulated Panels

Insulated Roof & Wall Panels. KS1000 TD Data Sheet. Topdek Single Ply Roof Deck. Insulated Panels Insulated Roof & Wall Panels KS1000 TD Data Sheet Topdek Single Ply Roof Deck Insulated Panels KS1000 TD Technical Data Product Overview Kingspan offers superior roof panel systems compared to conventional

More information

Cavity Tray Application

Cavity Tray Application Cavity Trays Cavity Tray Block Cavity Trays Page 4 Door & Window Cavity Trays Page 8 Lead Chimney Trays Page 9 Inter-loc Horizontal Cavity Trays Page 7 Lintel Cavity Trays Page 8 Brick Cavity Trays Page

More information

typical section 1:50 Important:

typical section 1:50 Important: 00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights 1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. TYPES OF COVERING 110 BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Substrate: Plywood to

More information

The better way to build TM. Installation Manual NAILBASE PANELS

The better way to build TM. Installation Manual NAILBASE PANELS The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

Insulated Panels. CI/SfB. September Thermatile System. Kingspan Insulated Facade Systems. Building to the Power of.

Insulated Panels. CI/SfB. September Thermatile System. Kingspan Insulated Facade Systems. Building to the Power of. Insulated Panels CI/SfB (47) Nh2 September 2008 Thermatile System Kingspan Insulated Facade Systems Building to the Power of Insurer Approved System Tile Colour: Rose Offers increased visual options and

More information

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request. is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

Trimapanel External wall panel system

Trimapanel External wall panel system Uniclass L5141:P41 CI/SfB (41) November 2015 Nh2 Trimapanel External wall panel system Contents 4-5 Introduction and benefits 6 Platinum Plus system guarantee 7 Colorcoat products and services 8-10 System

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an

More information

TYPICAL ROOF CONDITION LAYOUT

TYPICAL ROOF CONDITION LAYOUT FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/

More information

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

Insulated Panels. CI/SfB. April Thermatile System. Kingspan Insulated Facade Systems. Building to the Power of. Insurer Approved System

Insulated Panels. CI/SfB. April Thermatile System. Kingspan Insulated Facade Systems. Building to the Power of. Insurer Approved System Insulated Panels CI/SfB (47) Nh2 April 2006 Thermatile System Kingspan Insulated Facade Systems Building to the Power of Insurer Approved System Introduction 4 Product Data 8 Model Specifications 18 Introduction

More information

Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System

Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System NBS Specification KingZip SF Standing Seam Roofing System H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read with Preliminaries/General conditions. TYPE OF CLADDING SYSTEM 140 METAL PROFILED CLADDING

More information

GRP Flat Roofing Edge Trims

GRP Flat Roofing Edge Trims GRP Flat Roofing Edge Trims Compatible with GRP, rigid and flexible polyester, polyurethane, acrylic and alkyd systems. Trim Brochure and Technical Specification Guide General Information The Easy To Use

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT fully adhered waterproofing system

BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT fully adhered waterproofing system J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. TYPES OF COVERING 110A BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

B5 for garages, equestrian and other single storey buildings

B5 for garages, equestrian and other single storey buildings Cl/SfB l (4-) l Nf9 l March 2017 l B5 for garages, equestrian and other single storey buildings Corrugated sheet and accessories www.cembrit.co.uk Cembrit companies have been manufacturing corrugated sheets

More information

HOME SYSTEMS CONSTRUCTION PROCEDURE

HOME SYSTEMS   CONSTRUCTION PROCEDURE HOME SYSTEMS WWW.QUICKBUILTHOMES.COM.AU CONSTRUCTION PROCEDURE INDEX - PARTS LIST PARTS LIST QBRC75(C) QBRM75C) QBSIPS75 QBRFSZ75C QBRFBC75C QBRF3030G QBRGSQC QBRFRC75C QBRFZEC QBRF4040C QBSACC75 QBFR7330WC

More information

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR

More information

Specifications. Some details shown in this document have been reproduced from CCANZ document CP 01.

Specifications. Some details shown in this document have been reproduced from CCANZ document CP 01. BRICKVENEERS Specifications Bowers Brick Veneer meets the requirements of AS/NZS 4455 as a masonry brick veneer and complies with and exceeds the 15 year durability requirements as stated in the New Zealand

More information

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE: SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance

More information

Typical detail: New roof with breathable underlay

Typical detail: New roof with breathable underlay New roof with breathable underlay 6. WALLTITE CL00 insulation to achieve target U-value. Vapour control layer. Plasterboard and skim. Unventilated air space 5. WALLTITE returned to insulated cavity stop

More information

Corrugated sheet for single storey, sectional buildings and stables

Corrugated sheet for single storey, sectional buildings and stables Cl/SfB l (4-) Nf9 l l September 2011 l Corrugated sheet for single storey, sectional buildings and stables B5 Corrugated sheet and accessories Cembrit companies have been manufacturing corrugated sheets

More information

MetecnoSpan Standard Construction Drawings TEK SCREWS AND WASHERS TO EVERY RIB. ADDITIONAL FIIXINGS MAY BE REQUIRED, REFER ENGINEER FOR ASSESSMENT.

MetecnoSpan Standard Construction Drawings TEK SCREWS AND WASHERS TO EVERY RIB. ADDITIONAL FIIXINGS MAY BE REQUIRED, REFER ENGINEER FOR ASSESSMENT. TEK SCREWS AND WASHERS TO EVERY RIB. ADDITIONAL FIIXINGS MAY BE REQUIRED, REFER ENGINEER FOR ASSESSMENT. 75 CUTBACK FASTEN GUTTER BRACKET WITH SUITABLE LENGTH TEK SCREWS INTO FASCIA PURLIN OUTRIGGER FASCIA

More information

Thin Brick Façade. Façades Installation Guide

Thin Brick Façade. Façades Installation Guide Thin Brick Façade Façades Installation Guide October 2016 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels. Insulated panels serve as energy efficient,

More information

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Typical Details AcroWall-ES System Class PB Exterior Insulation and Finish System providing a primary moisture barrier 1. Typical AcroWall-ES System Application 2. Typical Aesthetic Reveal 3. Typical Window

More information

New versatile and effective dry fix solutions for the roofline and above

New versatile and effective dry fix solutions for the roofline and above Cavity trays Access panels Loft access doors Gas barrier and damp proofing accessories Under floor and through wall ventilation Cavity closers and stops Air leakage solutions New versatile and effective

More information

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

FACE CFP - HORIZONTAL PANELS - OPTION 'B' - Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

COMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER

COMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER CI-CFR-LG LEGEND CI-CFR-JT-01 PANEL JOINT CI-CFR-JT-02 PANEL JOINT SEQUENCE CI-CFR-JT-03 PANEL JOINT LAYOUT CI-CFR-SQ-01 PANEL INSTALLATION SEQUENCE

More information

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier.

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier. www.quakerwindows.com www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines for all Quaker products with nail fins New

More information

UNDERSTANDING DIFFICULT CRITICAL TRANSITIONS OF AVB SYSTEMS

UNDERSTANDING DIFFICULT CRITICAL TRANSITIONS OF AVB SYSTEMS UNDERSTANDING DIFFICULT CRITICAL TRANSITIONS OF AVB SYSTEMS COREY S ZUSSMAN AIA, NCARB, ALA, REWC, RWC, RRO, CDT, CQM, LEED AP BD+C PEPPER CONSTRUCTION Air Barrier Association of America (ABAA) is a Registered

More information

Product Data Sheet (rev c 16/7/15) Product: BENCHMARK Roofliner System

Product Data Sheet (rev c 16/7/15) Product: BENCHMARK Roofliner System APPLICATION The BENCHMARK Roofliner system is to be used as an insulated composite roof deck under site applied single-ply membranes or fully supported or self-supported aluminium, copper, zinc and stainless

More information

Insulated Panels. Design, Build, Excel. Trisomet. Trimapanel. Enviropanel. Designers Guide to:

Insulated Panels. Design, Build, Excel. Trisomet. Trimapanel. Enviropanel. Designers Guide to: Bailey s Production Facility, Mallusk. Tegral Twin-Skin Roofing and Cladding The Helix, Dublin. Tegral Roof Decking Insulated Panels Design, Build, Excel Designers Guide to: Trisomet Trimapanel Enviropanel

More information

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall

More information

Trent Hills Public Library 98 Bridge Street East Campbellford, Ontario

Trent Hills Public Library 98 Bridge Street East Campbellford, Ontario 6 7 8 0± 688± 0± 86± 8± 68± 878± A U/S OF SOFFIT,68± 66± A0 STACK PENETRATION RIDGE HEIGHT 7,7± A0 7 King St. Peterborough ON K9J R8 t. 70 7 f. 70 7 006 B NOTE: ROOFTOP MECHANICAL UNITS ARE TO BE LIFTED

More information

Technical & Installation Manual

Technical & Installation Manual Technical & Installation Manual Product Description and Construction Details March 2016 V2.1 Office: 0800 484 552 or 03-313 3672 E-Mail: info@villagestone.co.nz Web Site: www.villagestonechristchurch.co.nz

More information

Prestige Series 12. Installation guide

Prestige Series 12. Installation guide Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................

More information

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL

More information

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C Stratum Guard I and II System Installation Details Stratum Guard I and II DETAIL Table of Contents NOTE SG.0.0.01 SG.0.0.02

More information

rondo accessories CONTENTS:

rondo accessories CONTENTS: rondo accessories SUMMARY Rondo has a range of accessories to complement our steel wall and ceiling systems, which includes Top Hats, Reveal Beads and Angles, as well as a rod bending tool for suspended

More information

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900 CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900

More information

100 mm. 100 mm. 125 mm. 125 mm. 150 mm. 150 mm C003 C001 C269 C208 C055 C002. Tee Gee. Feather Edge. Shiplap. Open V. Open V.

100 mm. 100 mm. 125 mm. 125 mm. 150 mm. 150 mm C003 C001 C269 C208 C055 C002. Tee Gee. Feather Edge. Shiplap. Open V. Open V. 150 mm 100 mm 150 mm 100 mm 125 mm 125 mm C002 Shiplap C001 Shiplap C003 Open V C269 Open V C208 Feather Edge C055 Tee Gee C027 Starter trim C028 Wall starter trim C029 Drip starter trim C035 Drip/starter

More information

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER PART 1 - GENERAL 1.01 SUMMARY SECTION 07 65 00 FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER A. Section includes through wall masonry flashing system components for installation over sheathing where spray

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

Installation GUIDE STEEL DECKING SOLUTIONS FOR CONCRETE SLABS

Installation GUIDE STEEL DECKING SOLUTIONS FOR CONCRETE SLABS STEEL DECKING SOLUTIONS FOR CONCRETE SLABS Installation GUIDE Please take time to read this Truedek Installation Guide prior to site work commencing. It contains important delivery and installation information

More information

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall. SECTION 13125 - METAL BUILDING SYSTEMS PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall. 1. Eave Height: 13-0

More information

Eco Slate Installation Guide

Eco Slate Installation Guide Eco Slate Installation Guide Getting Started: Please ensure that you follow the installation guidelines and the correct procedures as any variance to this will void your warranty. Before starting please

More information

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate knowledge of metal roof and wall cladding systems

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate knowledge of metal roof and wall cladding systems Page 1 of 7 Title Demonstrate knowledge of metal roof and wall cladding systems Level 3 Credits 7 Purpose This unit standard is intended for use in the training and assessment of people carrying out metal

More information

Commercial Flashing Details

Commercial Flashing Details This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from

More information

Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

Specification. Project Name: Project reference: Written: by: Cathal Quinn   Tel: Project reference: 010050 Specification Written: by: Cathal Quinn Email: cathal@moymaterials.com Tel: 07788 934895 Project Name: Moy Materials Victoria House (4 th Floor) Victoria Road Chelmsford CM1 1JR

More information

Standing Seam Systems. Architectural Standing Seam Roofing System. KingZip SF

Standing Seam Systems. Architectural Standing Seam Roofing System. KingZip SF KIP_LLC Kingzip SF 16pp Update v11_feb14 24/02/2014 09:11 Page 1 Standing Seam Systems Architectural Standing Seam Roofing System KingZip SF KIP_LLC Kingzip SF 16pp Update v11_feb14 24/02/2014 09:11 Page

More information

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage

More information

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypLyner (walls) Metal framed wall lining system. GypLyner. GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal

More information

200 / 300 SERIES PANELS COLD STORAGE

200 / 300 SERIES PANELS COLD STORAGE CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES

More information

Wall & Facade Systems

Wall & Facade Systems Optimo 389 Architectural 417 KS1000 RW Trapezoidal 525 LS LongSpan 583 Insulated Wall & Facade Systems Insulated Wall & Facade Systems 387 388 Product Data 393 Model Specifications 397 Fastener Selection

More information

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2 Contents BCA Codes 3 General 4 Fire Performances Thermal and Acoustic Insulation Wall Installation 4 Timber Frame Separation Walls 5 Steel Frame Separation Walls 6 External Fire Rated Walls 7 Floor Installation

More information

Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board Acrocrete Platinum CI Stucco Typical details for an impact resistant

More information

Insulated Roof & Wall Panels. Kingspan K-Dek Product Guide. Kingspan K-Dek (KS1000 KD) High Performance Insulated Membrane Roofdeck System

Insulated Roof & Wall Panels. Kingspan K-Dek Product Guide. Kingspan K-Dek (KS1000 KD) High Performance Insulated Membrane Roofdeck System Insulated Roof & Wall Panels Kingspan K-Dek Product Guide Kingspan K-Dek (KS1000 KD) High Performance Insulated Membrane Roofdeck System Kingspan K-Dek Insulated Membrane Roofdeck Kingspan K-Dek is an

More information

OSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION

OSB.COMFORT INSTALLATION GUIDE *  1 RECOMMENDED USE PANEL COMPOSITION STYRO RAIL 07-0 Expanded Polystyrene Rigid Insulation combined to an Oriented Structural Board INSTALLATION GUIDE * 9 mm [8 ] The OSB.Comfort boards manufactured by Styro Rail are composed of type expanded

More information

Detail Booklet StoTherm ci XPS

Detail Booklet StoTherm ci XPS Detail Booklet Series 53sxx Steel Frame Construction February 2017 professional, general contractor or builder They should be installed in accordance with those specifications and Sto s instructions Sto

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

SMART ROOFS AFFORDABLE HOUSING LEISURE HOUSING STORAGE BUILDINGS BARNS GARAGES & CARPORTS GARDEN OR WOOD SHEDS.

SMART ROOFS AFFORDABLE HOUSING LEISURE HOUSING STORAGE BUILDINGS BARNS GARAGES & CARPORTS GARDEN OR WOOD SHEDS. SMART ROOFS AFFORDABLE HOUSING LEISURE HOUSING STORAGE BUILDINGS BARNS GARAGES & CARPORTS GARDEN OR WOOD SHEDS www.duracorroofing.com DURACOR www.duracorroofing.com DURACOR AN UNIVERSAL TYPE OF ROOFING

More information

AS The External Waterproofing Membranes Standard

AS The External Waterproofing Membranes Standard AS 4654-2 The External Waterproofing Membranes Standard NOTE This external waterproofing standard contains solutions for problems which have not been addressed in other countries. CONFORMANCE CONDITIONS

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied

More information