1 City of Medford Municipal Code Chapter 9 Presented by the Building Safety Department
2 THESE PROVISIONS PRESCRIBE THE DESIGN REQUIREMENTS OF EXISTING BUILDINGS UNDERGOING: CHANGE OF OCCUPANCY ADDITIONS ALTERATIONS SECTION 9.600
3 FOR CHANGE OF OCCUPANCY AND STRUCTURAL ADDITIONS THE DESIGN STANDARD SHALL BE THE CURRENT EDITION OF OREGON STRUCTURAL SPECIALTY CODE. FOR OTHER WORK COVERED UNDER THESE PROVISIONS THE DESIGN STANDARD SHALL BE FEMA 178, NEHRP HANDBOOK FOR THE SEISMIC EVALUATION OF EXISTING BUILDINGS. SECTION 9.610
4 THE USE OR CHARACTER OF A QUALIFIED HISTORIC BUILDING OR PROPERTY, OR PORTION THERE OF, SHALL BE PERMITTED TO CONTINUE IN USE REGARDLESS OF ANY PERIOD OF TIME IT MAY HAVE BEEN UNOCCUPIED OR IN OTHER USE; PROVIDED THE BUILDING OR PROPERTY OTHERWISE CONFORMS TO ALL APPLICABLE REQUIREMENTS OF THIS CHAPTER. SECTION 9.615
5 THE TABLE BELOW IS USED TO CLASSIFY THE RELATIVE HAZARD OF ALL BUILDING OCCUPANCIES; RELATIVE HAZARD OCC. CLASSIFICATION 5 (HIGHEST) A, E,I-1.1, 1-3, H-1, H-3, H-6, H-7 4 R-1, SR, 1-2, B, I-1.2, I-1.3, M 2 F, S, H-4, H-5 1 (LOWEST) R-3, U SECTION 9.620
6 AN OCCUPANCY CHANGE OF THE SAME OR A LOWER RELATIVE HAZARD CLASSIFICATION NUMBER WILL NOT REQUIRE SIESMIC IMPROVEMENTS, UNLESS THE CHANGE RESULTS IN AN OCCUPANT LOAD INCREASE OF MORE THAN 20% SECTION 9.620
7 AN OCCUPANCY CHANGE TO A HIGHER RELATIVE HAZARD CLASSIFICATION NUMBER WILL NOT REQUIRE SEISMIC IMPROVEMENTS, WHEN THE NET FLOOR AREA OF THE CHANGED PORTION OCCUPIES LESS THAN 15% OF THE NET FLOOR AREA OF THE BUILDING AND WHERE THE CHANGE DOES NOT RESULT IN AN INCREASE IN OCCUPANT LOAD AS DEFINED BY THE OREGON STRUCTURAL SPECIALTY CODE OF MORE THAN 100 PERSONS. SECTION 9.620
8 ALL OTHER CHANGES TO A HIGHER RELATIVE HAZARD OCUPANCY WILL REQUIRE SEISMIC IMPROVEMENTS USING THE CURRENT EDITION OF THE OREGON STRUCTURAL SPECIALTY CODE. SECTION 9.620
9 ALL STRUCTURES, WHICH ARE BEING CONVERTED TO ESSENTIAL FACILITIES, AS DEFINED IN THE OREGON STRUCTURAL SPECIALTY CODE, SHALL COMPLY WITH CURRENT SEISMIC REQUIREMENTS, REGARDLESS OF OTHER REQUIREMENTS IN THIS SECTION. SECTION 9.620
10 AN ADDITION THAT IS NOT STRUCTURALLY INDEPENDENT FROM AN EXISTING BUILDING SHALL BE DESIGNED AND CONSTRUCTED SUCH THAT THE ENTIRE BUILDING CONFORMS TO THE SEISMIC FORCE RESISTANCE REQUIREMENTS FOR NEW BUILDINGS UNLESS THE FOLLOWING THREE CONDITIONS ARE MET: SECTION 9.625
11 THE ADDITION SHALL COMPLY WITH THE REQUIREMENTS FOR NEW BUILDINGS, AND THE ADDITION SHALL NOT INCREASE THE SEISMIC FORCES IN ANY STRUCTURAL ELEMENT OF THE BUILDING BY MORE THAN 5 PERCENT UNLESS THE CAPACITY OF THE ELEMENT SUBJECT TO THE INCREASED FORCES IS EQUAL TO OR GREATER THAN THAT REQUIRED FOR NEW BUILDINGS, AND SECTION 9.625
12 THE ADDITION SHALL NOT DECREASE THE SEISMIC RESISTANCE OF ANY STRUCTURAL ELEMENT OF THE EXISTING BUILDING UNLESS THE REDUCED SEISMIC RESISTANCE OF THE ELEMENT IS EQUAL TO OR GREATER THAN THAT REQUIRED FOR NEW BUILDINGS. SECTION 9.625
13 IF A BUILDING IS DAMAGED BY FIRE, ALL DAMAGED LATERAL LOAD RESISTING COMPONENTS OF A BUILDING S STRUCTURAL SYSTEM MUST BE DESIGNED AND REBUILT TO CURRENT PROVISIONS OF THE OREGON STRUCTURAL SPECIALTY CODE. SECTION 9.630
14 THESE COMPONENTS MUST ALSO BE CONNECTED TO THE BALANCE OF THE UNDAMAGED LATERAL LOAD RESISTING SYSTEM IN CONFORMANCE WITH CURRENT CODE PROVISIONS. UNDAMAGED COMPONENTS NEED NOT BE UPGRADED TO CURRENT LATERAL LOAD PROVISIONS OF THE CURRENT CODE, UNLESS REQUIRED BY OTHER PROVISIONS OF THE OREGON STRUCTURAL SPECIALTY CODE. SECTION 9.630
15 WHEN AND ALTERATION, FOR WHICH A BUILDING PERMIT IS REQUIRED, HAS A VALUE OF MORE THAN $100,000 A FEMA 178 EVALUATION IS REQUIRED. A LETTER OF INTENT TO HAVE A FEMA 178 EVALUATION PERFORMED MAY BE SUBMITTED ALONG WITH THE PERMIT APPLICATION. THE EVALUATION MUST BE COMPLETED BEFORE ANY FUTURE PERMITS WILL BE ISSUED. THE FOLLOWING SHALL BE EXEMPTED FROM THIS REQUIREMENT: SECTION 9.635
16 BUILDINGS CONSTRUCTED OR RENOVATED TO SEISMIC ZONE 2, 2B OR 3 UNDER A PERMIT ISSUED AFTER JANUARY 1, ONE-AND-TWO FAMILY DWELLINGS. SINGLE STORY, LIGHT METAL BUILDINGS LESS THAN 5,000 SQUARE FEET IN AREA. LIGHT WOOD BUILDINGS LESS THAN 5,000 SQUARE FEET IN AREA. A PREVIOUSLY PREPARED SEISMIC STUDY MAY BE SUBMITTED FOR CONSIDERATION BY THE DEPARTMENT AS EQUIVALENT TO A FEMA 178 EVALUATION. SECTION 9.635
17 SEISMIC HAZARDS SHALL BE MITIGATED IN CONJUCTION WITH BUILDING ALTERATIONS AND REPAIRS IN UNREINFORCED MASONRY BUILDINGS, AS FOLLOWS: WHEN THE ROOF COVERING IS REPAIRED OR REPLACED, THE BUILDING STRUCTURAL ROOF SYSTEM, ANCHORAGE, AND PARAPET SHALL BE REPAIRED AND REHABILITATED PER APPENDIX C OF THE DESIGN STANDARDS- FEMA 178, OR SECTION 9.640
18 WHEN THE COST OF ALTERATION WORK WHICH REQUIRES A BUILDING PERMIT IN A 2 YEAR PERIOD EXCEEDS A $15 PER SQUARE FOOT FOR THE TOTAL NET FLOOR AREA IN THE BUILDING, THEN THE BUILDING SHALL BE IMPROVED SEISMICALLY PER SECTION SECTION 9.640
19 COSTS FOR SITE IMPROVEMENTS AND MANDATORY FM41 AGREEMENTS, MANDATED ADA IMPROVEMENTS, MANDATED LANDSCAPING AND MANDATED OR VOLUNTARY SEISMIC IMPROVEMENTS WILL NOT BE INCLUDED IN THE $15 PER SQUARE FOOT AMOUNT. SECTION 9.640
20 THE BUILDING SAFETY DIRECTOR MAY APPROVE A MULTI-YEAR PHASED PROGRAM OF SEISMIC IMPROVEMENTS WHEN THE IMPROVEMENTS ARE PRE-DESIGNED AND AN IMPROVEMENT/IMPLEMENTATION PLAN IS APPROVED BY THE BUILDING SAFETY DIRECTOR. THE MAXIMUM TOTAL TIME ALLOWED FOR COMPLETION OF PHASED IMPROVEMENTS SHALL BE TEN YEARS. SECTION 9.645
21 BUILDING PERMIT APPLICATIONS TO IMPROVE THE SEISMIC CAPABILITY OF A BUILDING SHALL NOT TRIGGER: ACCESSIBILITY IMPROVEMENTS SO LONG AS THE SEISMIC IMPROVEMENT DOES NOT LESSEN ACCESSIBILITY. FIRE LIFE SAFETY IMPROVEMENTS SO LONG AS THE SEISMIC IMPROVEMENT DOES NOT LESSON THE BUILDING S FIRE RESISTANCE OR EXITING CAPABILITY. SECTION 9.650
22 LANDSCAPE IMPROVEMENTS REQUIRED BY THE LAND DEVELOPMENT CODE CHAPTER 10. STREET TREE IMPROVEMENTS REQUIRED BY THE LAND DEVELOPMENTS CODE. CONFORMANCE WITH THESE INTERIM REGULATIONS MAY NOT EXEMPT BUILDINGS FROM FUTURE SEISMIC REQULATIONS. SECTION 9.650
23 BUILDING PERMIT, PLAN REVIEW AND FIRE LIFE SAFETY REVIEW FEES ARE WAIVED WHEN SUCH FEES TOTAL LESS THEN $2,500, AND REDUCED BY 50% WHEN SUCH FEES WOULD TOTAL $2,500 OR MORE. SECTION 9.655
24 BECAUSE UNANTICIPATED CIRCUMSTANCES MAY ARISE IN THE ENFORCEMENT OF THESE REQUIREMENTS FOR EXISTING BUILDINGS, CONSIDERATION AS TO THE REASONABLE APPLICATION OF THIS CHAPTER MAY BE ADDRESSED THROUGH THE UNITED APPEAL BOARD. SEE SECTION THROUGH SECTION 9.655
25 GUIDELINES FOR STRUCTURAL WORK IN EXISTING BUILDINGS APPLICATION FOR WORK ON EXISTING BUILDING ADDITION with LOAD > 5% on BLDG? No CHANGE OF OCCUPANCY (To higher hazard) OR 20% increase of occupant load? No PERMIT VALUE > $100,000? No URM BLDG. Unreinforced Masonry Bldg? Yes PERMIT VALUE >$15/Sq Ft? No ROOF REPAIR 50% or more of roof covering? No Any new structural elements requiring structural design or are fire-damaged structural elements being replaced? No Any work done to existing structural elements? No NO STRUCTURAL REQUIREMENTS Yes Yes Yes Yes Yes Yes Yes Upgrade building to UBC.1994 Upgrade building to UBC.1994 FEMA 178 EVALUATION REHABILITATE, CONFORM TO FEMA 178, appendix C ATTACH WALLS TO ROOF structure and BRACE PARAPETS as needed per FEMA 178, appendix c New elements conform to UBC.1994 Does work cause existing element to become overloaded? (Strength and / or stiffness) No Element can be modified without conforming to code for new work Yes Element must be improved to UBC.1994
Sponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts
Commonwealth of Massachusetts State Building Code 780-CMR 9 th Edition Renovation of Existing Buildings Using The International Existing Building Code IEBC 2015 with Massachusetts Amendments Sponsored
More informationEmeryville's Seismic Hazard Mitigation Ordinance
Emeryville's Seismic Hazard Mitigation Ordinance THIS IS THE CITY OF EMERYVILLE'S SEISMIC HAZARD MITIGATION ORDINANCE PASSED IN 1995 TO AMEND AND CLARIFY AN EARLIER ORDINANCE PASSED IN 1990. THIS ORDINANCE
More informationCity of Tacoma Planning and Development Services
City of Tacoma Planning and Development Services ORDINANCE NO. 28155 Adopt and Amend the City s Building Code; amending Title 2 of the Tacoma Municipal Code, implement the 2012 International Building,
More informationPRESCRIPTIVE COMPLIANCE METHOD
CHAPTER PRESCRIPTIVE COMPLIANCE METHOD 3 SECTION 301 GENERAL 301.2 Building materials. Building materials shall comply with the requirements of this section. 301.2.1 Existing materials. Materials already
More informationRESIDENTIAL SEISMIC RETROFITS
RESIDENTIAL Barry H. Welliver Structural Engineer BHW Engineers SEAU 6th Annual Education Conference Davis Conference Center - Layton, Utah February 21st, 2018 TOPICS Introduction to Seismic Retrofits
More informationBUILDING AND SAFETY DIVISION STRUCTURAL OBSERVATION - REVISITED, A YEAR LATER
BUILDING AND SAFETY DIVISION DATE: April 1, 1997 TO: FROM: All Structural Plan Check Staff All Building Inspection Staff All Supervisory Staff Engineers, Architects and Contractors Jack Phillips, Building
More informationStructural Engineering
Structural Engineering 4 4.0 TABLE OF CONTENTS 4.1 General Approach 115 Submission Requirements 4.2 Codes and Standards 116 Structural Design of New Buildings 116 Use of Recycled Materials 4.3 Structural
More informationFEMA P 50 & FEMA P 50 1
& Seismic Retrofit Guidelines for Detached, Single Family, Wood Frame Dwellings FEMA P 50 & FEMA P 50 1 & Seismic Retrofit Guidelines for Detached, Single Family, Wood Frame Dwellings FEMA P 50 1 & Seismic
More informationPRESCRIPTIVE COMPLIANCE METHOD
CHAPTER 3 PRESCRIPTIVE COMPLIANCE METHOD [B] SECTION 301 GENERAL 301.1 Scope. The provisions of this chapter shall control the alteration, repair, addition and change of occupancy of existing structures,
More information780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
780 CMR: MASSACHUSETTS AMENDMENTS TO THE INTERNATIONAL EXISTING BUILDING CODE 2009 CHAPTER 34: EXISTING STRUCTURES 101.1 Replace as follows: 101.1 Title. These regulations shall be known as e Existing
More informationSimplified Seismic Assessment & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & FEMA P-50-1
& Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & FEMA P-50-1 & Seismic Retrofit Guidelines for Detached, Single-Family, Wood-Frame Dwellings FEMA P-50 & Seismic
More informationCODE ANALYSIS REPORT SECOND FLOOR
CODE ANALYSIS REPORT SECOND FLOOR 384 DWIGHT STREET HOLYOKE, MA Prepared by Dietz & Company Architects, Inc. 17 Hampden Street Springfield, MA March 2014 INTRODUCTION The following report is a preliminary
More informationAvailable at: Last Modified: December 2012
6.3 Architectural Components 6.3.7 Chimneys and Stacks 6.3.7.1 Unreinforced Masonry Chimney Unreinforced masonry (URM) chimneys are extremely vulnerable to earthquake damage; their behavior has long been
More informationCommercial Remodel Permit
Commercial Remodel Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts, each
More informationCTC MEETING #25 CHILD WINDOW SAFETY REPORT
CTC MEETING #25 CHILD WINDOW SAFETY REPORT The Child Window Safety SG has not met following the 2012 Final Action Hearing. Group B activities did not necessitate SG meetings as the activity will be limited
More informationMandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC Division 93 Effective: 11/22/15 DOCUMENT NO.: P/BC 2014-137 Revised: 06/07/16 Previously Issued As: N/A Mandatory Wood Frame Soft-story
More informationTHE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:
ORDINANCE NO. An ordinance amending Sections 91.202, 91.3401, 91.3401.1,91.3405.2.1, 91.3405.2.2, 91.3405.2.3 and 91.3405.4 of Article I of Chapter IX of the Los Angeles Municipal Code to amend terms,
More information&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &
&01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.
More informationFEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION
INTRODUCTION Objective of provisions: The provisions of IEBC Appendix Chapter A3 are intended to reduce hazard of earthquake-induced damage (IEBC A301.1). These provisions are not intended to eliminate
More informationSEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON STRUCTURAL EVALUATION FOR PREPARED BY PCS STRUCTURAL SOLUTIONS
STRUCTURAL EVALUATION FOR SEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON PREPARED BY PCS STRUCTURAL SOLUTIONS NOVEMBER 1, 2017 17-733 TABLE OF CONTENTS Page I. PREFACE ii II. EXECUTIVE
More information2015 International Existing Building Code Overview Based on the International Existing Building Code (IEBC )
Goal 2015 International Existing Building Code Overview Based on the International Existing Building Code (IEBC ) To identify and describe key provisions of the 2015 IEBC. 2015 IEBC Overview 3 Description
More informationCode Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)
Code Requirements for Existing Buildings R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com R.W. Sullivan Engineering (RWS) was established in 1945 and currently
More informationTHE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:
ORDINANCE NO. 184163 An ordinance amending Sections 91.202, 91.3401, 91.3401.1, 91.3405.2.1, 91.3405.2.2, 91.3405.2.3 and 91.3405.4 of Article I of Chapter IX of the Los Angeles Municipal Code to amend
More informationSTRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Chapter 85 Effective: 01-01-2011 DOCUMENT NO.: P/BC 2011-110 Revised: Previously Issued As: P/BC 2002-110 STRUCTURAL DESIGN REQUIREMENTS
More informationCALIFORNIA BUILDING AND SAFETY COMMISSIONERS. nmi 'DEI ERIC GARCETTI MAYOR PROPOSED SUBSTANTIAL STRUCTURAL DAMAGE ORDINANCE- COUNCIL FILE
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS INTERIM PRESIDENT E, FELICIA BRANNON JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ City of Los Angeles CALIFORNIA nmi 'DEI ERIC GARCETTI
More informationChapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE
Chapter 23.12 UNIFORM CODES FOR CONSTRUCTION BUILDING CODE 23.12.010 Adoption of the 2010 California Building Code. Part 2. Title 24 of the California Code of Regulations. There is adopted and incorporated
More information2012 IEBC Fundamentals 12/11/2017. Copyright 2012 International Code Council 1
Overview 2012 IEBC Fundamentals The purpose of the IEBC is to encourage the use and re-use of existing buildings while requiring reasonable upgrades and improvements Based on the 2012 International Existing
More informationOctober 25, Honorable Mayor and City Council. THROUGH: Public Safety Committee. Planning Department
October 25,201 0 TO: Honorable Mayor and City Council THROUGH: Public Safety Committee FROM: Planning Department SUBJECT: PREPARATION OF AN ORDINANCE ADOPTING THE CALIFORNIA CODE OF REGULATIONS TITLE 24
More informationCommercial Reroof Permit Program
Commercial Reroof Permit Program Category: Commercial Construction Revised: [Paul L.Scarlett], Director Responsible Bureau Section: Development Services Center Permitting Services/Trade Permits 1900 SW
More informationADMINISTRATIVE BULLETIN. TITLE : Procedures for Implementation of SFBC Chapter 34B
ADMINISTRATIVE BULLETIN NO. : DATE : September 19, 2013 SUBJECT : Seismic Strengthening of Soft Story Wood Frame Buildings TITLE : Procedures for Implementation of SFBC Chapter 34B PURPOSE : The purpose
More information3.5 Tier 1 Analysis Overview Seismic Shear Forces
Chapter 3.0 - Screening Phase (Tier ) 3.5 Tier Analysis 3.5. Overview Analyses performed as part of Tier of the Evaluation Process are limited to Quick Checks. Quick Checks shall be used to calculate the
More informationHALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE
HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE BE IT ENACTED by the Council of the Halifax Regional Municipality under the authority of the Building Code Act as follows:
More informationCommercial Solar Photovoltaic System Permit
Commercial Solar Photovoltaic System Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning
More informationTitle 15 BUILDINGS AND CONSTRUCTION
Title 15 BUILDINGS AND CONSTRUCTION Chapters: 15.04 International Codes Adopted 15.08 Building Permits 15.12 Movement of Buildings Chapter 15.04 INTERNATIONAL CODE COMMISSION CODES Sections: 15.04.010
More informationChapter 13C GREEN BUILDING REQUIREMENTS
1 of 8 9/12/2008 11:04 AM San Francisco Building Inspection Commission (BIC) Codes BUILDING CODE 2007 Edition Chapter 13C GREEN BUILDING REQUIREMENTS 1 Chapter 13C GREEN BUILDING REQUIREMENTS [Added 9-4-2008
More informationA minimum of 25% of any money spent upgrading areas of primary function shall be devoted to ADA upgrades. Existing non-compliant areas include:
October 23, 2012 PIX THEATER BUILDING CODE ANALYSIS 461 N 1 st St Woodburn, OR 97071 Executive Summary Since the most recent use in the building was a furniture store, the existing legal occupancy classification
More information1.0 General Provisions
1.0 General Provisions 1.1 Scope This Handbook provides a three-tiered process for seismic evaluation of existing buildings in any region of seismicity. Buildings are evaluated to either the Life Safety
More informationTOWN OF ECKVILLE BYLAW 638/02 BUILDING PERMIT BYLAW
TOWN OF ECKVILLE BYLAW 638/02 BUILDING PERMIT BYLAW A BYLAW OF THE TOWN OF ECKVILLE OR REGULATING THE FORM, CONTENT, AND COST OF PERMITS FOR THE USE, RELOCATION, CONSTRUCTION, AND DEMOLOTION OF BUILDINGS.
More informationCEQA Categorical Exemption Determination
CEQA Categorical Exemption Determination PROPERTY INFORMATION/PROJECT DESCRIPTION Project Address REC & PARK: JURI COMMONS PARK RENOVATION Case No. 2018-009517ENV Block/Lot(s) 6532008 Permit No. Addition/
More informationMinnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017
Minnesota Healthcare Engineers Association, Fall Conference Bob Dehler, P.E. Engineering Program Manager September 14, 2017 Categories of Rehabilitation Work in Healthcare Facilities Bob Dehler, P.E. robert.dehler@state.mn.us
More informationWABO TCD ASSEMBLY MOTION VOTING RECOMMENDATIONS (2016 GROUP B)
WABO TCD ASSEMBY VOTING RECOMMENDATIONS (2016 GROUP B) The suggestions contained in this Voter Recommendation ist are the opinions of the WABO Technical Code Development Committee (TCDC) members only and
More information2015 IBC Chapters 1 and 35
Study Session 1 2015 IBC Chapters 1 and 35 Administration OBJECTIVE: To obtain an understanding of the administrative provisions of the International Building Code Ò (IBC Ò ), including the scope and purpose
More informationgwinnettcounty RACKING SHELVING CONVEYOR CONSTRUCTION CODE COMPLIANCE GUIDELINES Permitting Procedure
Plan review and permitting requirements for storage systems such as storage racks, storage shelving, pallet racks, movable shelf racks, and conveyors. Permitting Procedure A Building Permit (BLD) is required
More informationPROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition
PROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition Chapter 1 GENERAL SECTION 101 GENERAL 101.1 Title. These regulations shall be known as the California San Francisco Green Building Standards
More informationSEISMIC DESIGN GUIDELINES
INTRODUCTION The purpose of these Seismic Design Guidelines is to provide additional information and clarification to Civil or Structural engineers in order to comply with Ordinance No. 18-O- 2767 for
More informationCOMMERCIAL BUILDING PERMIT
COMMERCIAL BUILDING PERMIT TOWNSHIP OF UPPER ST. CLAIR 1820 McLaughlin Run Road, Upper St. Clair PA 15241 Phone: 412.831.9000 Ext. 501 FAX: 412.854.0773 www.twpusc.org OFFICE USE CASE NO: BLD/ZON PROPERTY
More informationBUILDING PERMIT APPLICATION PACKAGE
BUILDING PERMIT APPLICATION PACKAGE NOTICE TO BUILDING PERMIT APPLICANTS In addition to completed applications forms, the following documentation is required to accompany all building permit applications
More informationADMINISTRATION CHAPTER 1
CHAPTER 1 ADMINISTRATION PART 1 SCOPE AND APPLICATION SECTION 101 SCOPE AND GENERAL REQUIREMENTS 101.1 Title. This code shall be known as the Florida Building Code, Energy Conservation, and shall be cited
More information101.1 Title. These regulations shall be known as the Existing Building Code of Massachusetts, hereinafter referred to as this code.
This file incorporates comment from numerous stakeholders and building officials, staff, two BBRS advisory committees (SAC and C34AC), and others into the original redline code proposal approved by the
More informationBuilding Code 8 th Edition
Massachusetts State Building Code 8 th Edition Kevin S. Hastings, P.E., LEED AP R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com RW R.W. Sullivan Engineering
More informationTable 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)
2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1
More informationDeck Permit Zoning requirements Adopted Code Submission Requirements Fees Review time Contractor licensing Inspections
Deck Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts, each with minimum
More informationSignage Code. H101.2 Signs exempt from permits. The following signs are exempt from the requirements to obtain a permit before erection:
Signage Code ICC Code: Appendix H: Signs SECTION H101 GENERAL H101.1 General. A sign shall not be erected in a manner that would confuse or obstruct the view of or interfere with exit signs required by
More informationPermit and Application Fee Schedule Plan Review Fees are in addition to permit application fees.
,. Permit and Application Fee Schedule 01-01-2016 Plan Review Fees are in addition to permit application fees. RESIDENTIAL Building area is defined as; the sum of the areas of all finished floors, including;
More informationSANTA BARBARA COUNTY ZONING ADMINISTRATOR STAFF REPORT October 21, 2011
SANTA BARBARA COUNTY ZONING ADMINISTRATOR STAFF REPORT October 21, 2011 PROJECT: Gilson Move Dwelling HEARING DATE: November 7, 2011 STAFF/PHONE: J. Ritterbeck, (805) 568-3509 GENERAL INFORMATION Case
More informationINTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004
CITY OF MERCER ISLAND 9611 SE 36 th Street, Mercer Island, Washington 98040-3732 PHONE (206) 236-5300 FAX (206) 236-3645 TDD (206) 232-9598 www.ci.mercer-island.wa.us INTERNATIONAL BUILDING CODE - ADOPTION
More informationTohono O odham Nation. Adoption of Building Codes
Tohono O odham Nation Adoption of Building Codes History; International Building Code (IBC) In 1915, the Building Officials and Code Administration (BOCA) was established. This organization developed what
More informationNew Commercial Construction Permit
New Commercial Construction Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts,
More informationORDINANCE NO. 16- The City Council of the City of West Hollywood does hereby ordain as follows:
Page 1 ORDINANCE NO. 16- AN ORDINANCE OF THE CITY OF WEST HOLLYWOOD ESTABLISHING SEISMIC STRENGTHENING REQUIREMENTS FOR FOUR CATEGORIES OF EXISTING BUILDINGS IN THE CITY AND AMENDING THE WEST HOLLYWOOD
More informationCode Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)
Code Requirements for Existing Buildings R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com R.W. Sullivan Engineering (RWS) was established in 1945 and currently
More informationTITLE 15: BUILDINGS AND CONSTRUCTION GENERAL PROVISIONS
TITLE 15: BUILDINGS AND CONSTRUCTION Chapter 15.01 GENERAL PROVISIONS 15.02. OREGON MECHANICAL SPECIALTY CODE ADOPTION 15.04. DANGEROUS BUILDINGS CODE 15.05. UNIFORM CODE FOR BUILDING CONSERVATION 15.06.
More informationRequirements for Municipal and Private Developments Document Last Updated in Database: April 27, 2016
Topic: Resource Type: State: Jurisdiction Type: Municipality: Year (adopted, written, etc.): 2009 Community Type applicable to: Green Buildings & Energy Efficiency Regulations California Municipal City
More informationCLEAR CREEK COUNTY BUILDING DEPARTMENT PERMIT PROCEDURES AND REQUIREMENTS FOR COMMERCIAL AND MULTI-FAMILY DEVELOPMENTS
CLEAR CREEK COUNTY BUILDING DEPARTMENT PERMIT PROCEDURES AND REQUIREMENTS FOR COMMERCIAL AND MULTI-FAMILY DEVELOPMENTS After all of your other permits have been issued and your construction plans and site
More information635 BUREAU OF BUILDING CODES AND STANDARDS MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE
16 DEPARTMENT OF PUBLIC SAFETY 635 BUREAU OF BUILDING CODES AND STANDARDS Chapter 3: MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE SUMMARY: This chapter establishes the Commercial
More informationMunicipal Services Agency Building Inspection General Information: (916)
Municipal Services Agency Building Inspection General Information: (916) 875-5296 www.bldginspection.org 4101 Branch Center Rd Sacramento 95827 Fax (916) 854-9228 827 7 th St Room 102 Sacramento 95814
More informationOrdinance No July 1, 2016
(Insert Facing Page 3 IRC) 2.02.540 Amendment to IRC Section R105.2 Work Exempt From Permit, Building and Electrical Sections. The following additional exception shall be added to R105.2 Building: Building:
More informationAlameda County Assessor s Records. Step 1. Fill-in the Building Owner information below, and then go to Step 2. Building Owner NAME.
CITY OF OAKLAND 250 FRANK H. OGAWA PLAZA SUITE 2340 OAKLAND, CALIFORNIA 94612-2031 Department of Planning and Building (510) 238-6402 www.oaklandnet.com FAX: (510) 238-2959 TDD: (510) 238-3254 Earthquake
More informationHAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS
Appendix A HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS PROJECT PERMIT APPLICANT PRIMARY RDP OF RECORD STRUCTURAL ENGINEER OF RECORD This Statement of Special Inspections is submitted as a condition
More informationADMINISTRATIVE BULLETIN. TITLE : Local Equivalency for Exiting Through a Garage Area for Type V, Group R Buildings
2001 SAN FRANCISCO BUILDING CODE AB-020 ADMINISTRATIVE BULLETIN NO. AB-020 DATE : September 18, 2002 SUBJECT : Fire and Life Safety TITLE : Local Equivalency for Exiting Through a Garage Area for Type
More informationFill out all sections or mark with N/A (not applicable)
TOWN of PLAINVILLE 142 South St Plainville, MA. 02762 508-695-3010 ext#12 / fax # 508-695-1857 Commercial Building Permit BUILDING PERMIT INSTRUCTIONS and APPLICATION Please be advised that any incomplete
More informationThe International Building Code (IBC ) is a model code that provides minimum requirements to safeguard the public health, safety and general welfare
AIA Austin is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of this program will be reported to AIA/CES for AIA
More informationStructural Design Issues for Housing and Small Buildings in British Columbia: Information for Local Authorities, Homeowners and Developers
The Association of Professional Engineers and Geoscientists of BC Structural Design Issues for Housing and Small Buildings in British Columbia: Information for Local Authorities, Homeowners and Developers
More informationThe Commonwealth of Massachusetts Department of Public Safety Code and Other Requirements for Building Permits Filing Instructions
The Commonwealth of Massachusetts Department of Public Safety Massachusetts State Building Code (780 CMR) Building Permit Application to Construct, Repair, Renovate or Demolish any Building other than
More information3. SURVEY AND ASSESSMENT PROCEDURES FOR EXISTING BUILDINGS
3. SURVEY AND ASSESSMENT PROCEDURES FOR EXISTING BUILDINGS The first step toward reducing the nonstructural hazards in an existing building is to perform a survey to assess the extent and magnitude of
More informationJDB CODE SERVICES, INC.
JDB CODE SERVICES, INC. July 8, 2015 Fred Dudley Dudley, Sellers, and Healy, P.L. SunTrust Financial Center, Suite 301 3522 Thomasville Road Tallahassee, Florida 32308 Subject: Opinion Letter on Florida
More informationHONEY BROOK TOWNSHIP
HONEY BROOK TOWNSHIP BUILDING PERMIT DATA INFORMATION PACKET FOR PLACEMENT OF A MOBILE (MANUFACTURED) HOME UNDER THE UNIFORM CONSTRUCTION CODE (UCC) EVERYTHING IN THIS PACKET IS IMPORTANT. READ EVERYTHING
More informationFill out all sections or mark with N/A (not applicable)
TOWN of PLAINVILLE 142 South St Plainville, MA. 02762 508-695-3010 ext#12 / fax # 508-695-1857 Commercial Building Permit BUILDING PERMIT INSTRUCTIONS and APPLICATION Please be advised that any incomplete
More informationCTC to BCAC IBC/ADA Coordination/ IEBC 3-2, 4-1 thru 4-8a, 7-1 thru 7-3, 8-1, 12-1, 14-1 and 15-1
CTC to BCAC IBC/ADA Coordination/ IEBC 3-2, 4-1 thru 4-8a, 7-1 thru 7-3, 8-1, 12-1, 14-1 and 15-1 2015 Group A Code Change Cycle Copyright 2014 International Code Council, Inc. IEBC 3-2 301.1 Proponent:
More informationBurbank Municipal Code A300: ADOPTION OF CODE: Page 8 of 13
Burbank Municipal Code 9-1-7-A300: ADOPTION OF CODE: Page 8 of 13 D. Details shall include existing and new anchors and the method of development of anchor forces into the diaphragm framing; existing and/or
More informationCHAPTER 6 INTERNATIONAL RESIDENTIAL CODE
CHAPTER 6 INTERNATIONAL RESIDENTIAL CODE Sec.3-6-1. Adoption of the International Residential Code. That certain documents three copies of which are on file in the office of the village clerk, being marked
More information(d) Metal buildings used for industrial uses are not exempt from additional landscape standards as required in Section (e).
5.22. Non-Residential and Multifamily Design Standards. 5.22-1 Applicability of Non-Residential Design Standards. All non-residential and multifamily buildings, with the exception of those described in
More informationSolar Photovoltaic System Permit
Solar Photovoltaic System Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts,
More informationThe Council of the City of Palo Alto does ORDAIN as follows:
ORDINANCE NO. 4976 ORDINANCE OF THE COUNCIL OF THE CITY OF PALO ALTO REPEALING CHAPTER 16.04 OF THE PALO ALTO MUNICIPAL CODE AND AMENDING TITLE 16 TO ADOPT A NEW CHAPTER 16.04, CALIFORNIA BUILDING CODE,
More informationSITE PLAN CRITERIA FOR MUNICIPAL SOLID WASTE & RECYCLABLES STORAGE & ENCLOSURE REQUIREMENTS
SITE PLAN CRITERIA FOR MUNICIPAL SOLID WASTE & RECYCLABLES STORAGE & ENCLOSURE REQUIREMENTS April 2009 General Solid Waste and Recycling Service Responsibilities: The City of Denton is the exclusive provider
More informationARTICLE 10: Wireless Services and Communications
ARTICLE 10: Wireless Services and Communications... 10-1 17.10.1: General... 10-1 17.10.1.1: Purpose and Intent... 10-1 17.10.1.2: Applicability... 10-1 17.10.2: Wireless Facilities By Zone District...
More informationCEQA Categorical Exemption Determination
CEQA Categorical Exemption Determination PROPERTY INFORMATION/PROJECT DESCRIPTION Project Address Block/Lot(s) REC & PARK: 210V HYDE STREET 0336/003 Case No. 2017-016267ENV Permit No. Addition/ Alteration
More informationInspection and Quality Assurance Requirements for Metal Plate Connected Wood Trusses. Educational Overview
Inspection and Quality Assurance Requirements for Metal Plate Connected Wood Trusses Educational Overview Introduction What do the codes say about requirements for inspection and quality assurance of trusses?
More informationIndividual Truss Marking Is it a Building Code Requirement?
Introduction: Individual Truss Marking Is it a Building Code Requirement? Released April 1, 2010 On January 1, 2008, the 2007 edition of the California Building Code (CBC) 1 was adopted for use and replaced
More informationCulver City Building Safety Division Mandatory Green Building Program
Effective June 2009 Culver City Building Safety Division Mandatory Green Building Program Category 1 Qualifying Projects All new construction, new additions, and major renovations in Culver City up to
More informationDRAFT ORDINANCE NO. RD:JAC:CER 9/1/2016
ORDINANCE NO. DRAFT AN ORDINANCE OF THE CITY OF SAN JOSE AMENDING VARIOUS SECTIONS OF TITLE 24 (TECHNICAL CODES) OF THE SAN JOSE MUNICIPAL CODE TO ADOPT THE 2016 CALIFORNIA BUILDING, RESIDENTIAL, PLUMBING,
More information2012 NC Energy Conservation Code (2012 NCECC) Commercial Building Compliance
2012 NC Energy Conservation Code (2012 NCECC) Commercial Building Compliance Billy Hinton, PE NC Department of Insurance Engineering Division Code Services Section Objectives Today we will address: 1.
More informationPhoenix Building Construction Code Updated Amendments to the Administrative Provisions
Phoenix Building Construction Code Updated Amendments to the Administrative Provisions CHAPTER 1 ADMINISTRATION Section 101.2 Change to read as shown: 101.2 Scope. The provisions of this Code shall apply
More informationADDENDA #9- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services
ADDENDA #9- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services Addenda Dated: 01/25/2019 PURPOSE: The purpose of this Addenda #9 is to provide a
More informationEXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS
HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS POLICY STATEMENT This policy applies to NEW Hood and Duct systems. The Authority Having Jurisdiction will not waive major criteria in the applicable standards
More informationRESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS
RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS New Construction, Addition, or Alteration All plans submitted must be prepared, sealed, and signed by a Registered Nebraska Design Professional
More informationCITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application
CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application DATE: / / PERMIT # REQUEST FOR: NEW BUILDING ADDITION REMODEL PLUMBING ONLY ELECTRIC ONLY
More informationCHAPTER 34 EXISTING BUILDINGS
CHAPTER 34 EXISTING BUILDINGS SECTION 3401 GENERAL 3401.1 Scope. Provisions of this chapter shall govern the application of this code to existing buildings. Exception: Buildings and structures located
More informationSUMMARY OF FIRE SPRINKLER REQUIREMENTS FOR ALTERATIONS TO EXISTING BUILDINGS 2015 I-Codes
SUMMARY OF FIRE SPRINKLER REQUIREMENTS FOR ALTERATIONS TO EXISTING BUILDINGS 2015 I-Codes SCOPE: The City of Lawrence requirements for application of current code provisions. This shall apply to alterations
More informationCity of Placerville Planning Commission AGENDA
Item 4.2 Placerville, a Unique Historical Past Forging into a Golden Future City of Placerville Planning Commission AGENDA MEETING DATE: January 19, 2016 APPLICATION & NO: 2845 Pleasant Street - Site Plan
More informationNeighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations
Section 16.20.020 - Neighborhood Suburban Single-Family Districts ( NS ) Sections: Typical Block in a Neighborhood Suburban District 16.20.020.1 History and Composition of Suburban Neighborhoods 16.20.020.2
More information