Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.

Size: px
Start display at page:

Download "Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code."

Transcription

1 LEGACY REPORT ER-2895 Reissued March 1, Business/Regional Office 5360 Workman Mill Road, Whittier, California (562) Regional Office 900 Montclair Road, Suite A, Birmingham, Alabama (205) Regional Office 4051 West Flossmoor Road, Country Club Hills, Illinois (708) Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code DIVISION: 03 Section: Concrete Anchoring HDI EXPANSION S HILTI, INC SOUTH 122 ND EAST AVENUE TULSA, OKLAHOMA SUBJECT HDI Concrete Expansion Anchors. 2.0 DESCRIPTION 2.1 General: HDI concrete expansion anchors are drop-in anchors for use in normal-weight and structural lightweight concrete. The anchoring system is an alternative to cast-in-place anchors described in Section 1912 of the 2000 International Building Code (IBC) and Section of the 1997 Uniform Building Code (UBC). The anchors may also be used where an engineered design is submitted in accordance with Section R of the 2000 International Residential Code (IRC). 2.2 Description: Anchors: The anchors consist of a one-piece circular outer shell and an expansion plug. The shell has internal threads at one end and four slots cut axially on the expansion end. The internal surface of the expansion end is tapered to match the expansion plug. The shell finish conforms to SC1, Type III, of ASTM B 633. The outer shells of the HDI anchors are manufactured from steel complying with AISI 12L14. The expander plug has an oil-coated finish and is manufactured from carbon steel. See Table 1 and Figure 1 for additional details Bolts: The bolts are provided by others and shall comply with ASTM A 307, ASTM A 325, or SAE J 429 Grade Concrete: Normal-weight and structural lightweight concrete shall conform to Sections 1903 and 1905 of the IBC and the UBC. 2.3 Design: General: Allowable shear and tension loads are as set forth in Tables 3 through 6, 8 and 9. Load factors for reduced spacings and edge distances are presented in Table 7. Allowable loads for anchors installed in normal-weight concrete and subjected to combined shear and tension loads, are determined by the following equation: where: (P s /P t ) + (V s /V t ) # 1 P s = Applied service tension load. P t = Allowable service tension load. V s = Applied service shear load. V t = Allowable service shear load Combined loads for anchors installed in structural lightweight concrete are addressed by the following equation: (P s /P t ) 5/3 + (V s /V t ) 5/3 # 1 Combined loads for anchors installed through steel deck and into structural lightweight concrete are beyond the scope of this report. The bolt or threaded rod used to attach the fixture to the HDI anchor shall be designed for allowable loads in accordance with applicable requirements in Chapter 22 of the IBC or the UBC Short-term Seismic or Wind Loading: Where permitted in the tables, allowable loads shall be permitted to be adjusted in accordance with Section of the UBC and Section of the IBC. 2.4 Installation: The anchors must be installed in holes perpendicular to the concrete surface, predrilled with drill bits complying with ANSI B , with the depth and diameter for each anchor size, as set forth in Table 2. The holes must be cleaned with compressed air of all cuttings. The anchor must be placed with the anchor embedment as noted in Tables 3 through 6, 8 and 9, and set by inserting the expansion plug into the anchor shell and driving the expansion plug with a setting tool and hammer. The setting tool shall be driven into the anchor until contact is made between the shoulder of the setting tool and the top of the anchor, when proper expansion occurs. A setting tool specific to each anchor is provided by Hilti, Inc. See Table 2 for setting tool designations and Figure 2 for additional details. Bolts described in Section are threaded into the anchor and tightened with a torque not exceeding the values noted in Table 2. Concrete edge distance and anchor spacing are specified in Tables 3 through 6, 8 and 9. ICC-ES legacy reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2004 Page 1 of 6

2 Page 2 of 6 ER Inspection: When special inspection is required, compliance with Section 1701 of the UBC or Section 1704 of the IBC is necessary. inspection in accordance with Section 1704 of the IBC shall be provided under the IRC when special inspection is specified in Table 2. The special inspector must be on the jobsite continuously during anchor installation. The building official shall receive a report, from an approved special inspector, that includes the following details: 1. Anchor description, including the anchor product name, nominal anchor and bolt diameters, and anchor length. 2. Hole description, including verification of drill bit compliance with ANSI B , hole depth and cleanliness. 3. Installation description, including verification of concrete compressive strength by ASTM C 42 methods and verification of anchor installation and location (anchor setting, spacing, edge distance, slab thickness, anchor embedment, and bolt tightening torque) in accordance with Hilti s published installation instructions and this report. 2.6 Identification: Each anchor shell is embossed with the company name (Hilti) and the anchor diameter designation which corresponds to the bolt diameter. In addition to this information, labels on the anchor packages bear the HDI product designation, the catalog number and the evaluation report number (ER-2895). The packaging for the anchors also bears the name of the inspection agency (Underwriters Laboratories, Inc.). 3.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Expansion Anchors in Concrete and Masonry Elements (AC01), dated April 2002, and quality control manuals. 4.0 FINDINGS That the HDI Concrete Expansion Anchors described in this report comply with the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code, subject to the following conditions: 4.1 Anchor sizes and dimensions are as set forth in this report. 4.2 The HDI Concrete Expansion Anchors are installed in accordance with Section 2.4 of this report. 4.3 Calculations and details demonstrating compliance with this report shall be submitted to the building official for approval. 4.4 The use of anchors is limited to installation in uncracked concrete. Cracking occurs when f t > f r due to service loads or deformations. 4.5 The HDI Concrete Expansion Anchors are used to resist dead loads and live loads. The HDI Concrete Expansion Anchors are permitted to be used to resist short-term loads, such as those resulting from wind or earthquake, when installed in normalweight concrete (see Tables 3 and 4) and structural lightweight concrete (see Tables 5 and 6). Use of HDI Concrete Expansion Anchors to resist shortterm loads, such as those resulting from wind or earthquake, when installation is through steel deck and into lightweight concrete (see Tables 8 and 9) is beyond the scope of this report. 4.6 Anchors are not permitted for use in conjunction with fire-resistive construction. Exceptions would be: Anchors resist wind or seismic loading only. For other than wind or seismic loading, special consideration is given to fire exposure conditions. 4.7 Use of anchors is limited to dry, interior locations. 4.8 Since an ICC-ES acceptance criteria for evaluating data to determine the performance of expansion anchors subjected to fatigue or shock loading is unavailable at this time, the use of these anchors under these conditions is beyond the scope of this report. 4.9 The Hilti HDI Concrete Expansion Anchors are manufactured by Hilti, Inc., at their facility in Zhan Jiang, Guangdong Province, People's Republic of China, with quality control follow-up inspections by Underwriter's Laboratories Inc. (AA-668). This report is subject to re-examination in two years.

3 Page 3 of 6 ER-2895 TABLE 1 DESCRIPTION CATALOG NO. MATERIALS HDI 1/4 AISI 12L HDI 3/8 AISI 12L HDI 1/2 AISI 12L HDI 5/8 AISI 12L HDI 3/4 AISI 12L14 For SI: 1 inch = 25.4 mm. INTERNAL THREAD SIZES (UNC) (inch) OVERALL LENGTH 1 / 4 1 OVERALL DIAMETER (inch) USABLE THREAD LENGTH 3 / 8 7 / 16 3 / / 16 1 / 2 5 / 8 1 / / 8 11 / 16 5 / / / 32 7 / 8 3 / / / 8 SETTING TOOL HDI 1/4 HST 14 HDI 3/8 HST 38 HDI 1/2 HST 12 HDI 5/8 HST 58 TABLE 2 INSTALLATION REQUIREMENTS 1 DRILL BIT SIZE (inch) HOLE 3 / 8 1 BOLT DIAMETER (inch) MAXIMUM TIGHTENING TORQUE 1 (foot-pounds) 1 / / / 16 3 / / / / / 16 5 / 8 37 HDI 3/4 HST / 16 3 / 4 80 For SI: 1 inch = 25.4 mm, 1 foot-pound = N-m. 1 Bolts threaded into the anchor must not be tightened with a torque greater than that noted in the table. TABLE 3 ALLOWABLE TENSION LOADS FOR S INSTALLED IN NORMAL-WEIGHT 1,2,3,4,5 (pounds) EDGE With COMPRESSIVE STRENGTH 2,000 psi 4,000 psi 6,000 psi Without With Without With Without HDI 1/ / HDI 3/8 1 9 / / / , , HDI 1/ , , ,345 1,170 HDI 5/8 2 9 / / ,235 1,120 2,920 1,460 3,720 1,860 HDI 3/4 3 3 / / / 8 2,995 1,500 4,065 2,030 5,560 2,780 For SI: 1 inch = 25.4 mm, 1 psi = kpa, 1 pound = 4.45 N. 1 The tabulated allowable load values are for anchors installed in normal-weight concrete having the designated ultimate compressive strength at time of anchor installation. 2 The tabulated values are for anchors installed at the specified anchor spacing and concrete edge distance. 3 Concrete edge distance or anchor spacing may be reduced to the minimum edge distances and spacings specified in Table 7 provided the load factors of Table 7 are applied to the tabulated allowable loads. Concrete edge distances for the HDI 1 / 4 -inch anchors installed in concrete with a compressive strength of less than 6,000 psi must not be reduced from those specified in Table 3. 4 When resisting short-term seismic or wind loading, allowable tension loads may be increased 33 1 / 3 percent in accordance with Section of the UBC or Section of the IBC. 5 Concrete slab thickness must be at least 1.5 times the anchor embedment. Compliance with Section of the UBC or Section of 6 These tension values are only applicable when the anchors are installed with special inspection as set forth in Section 2.5 of this report. 7 These tension values are applicable when the anchors are installed without special inspection.

4 Page 4 of 6 ER-2895 TABLE 4 ALLOWABLE SHEAR LOADS FOR S INSTALLED IN NORMAL-WEIGHT 1,2, 3, 4, 5 (pounds) EDGE VALUE BASED ON 6 VALUE BASED ON BOLT 6 Concrete Compressive Strength ASTM A 307 ASTM A 325 or SAE J 429 2,000 psi 4,000 psi 6,000 psi Grade 5 HDI 1/ / ,030 HDI 3/8 1 9 / / / ,090 1,440 1,105 2,310 HDI 1/ ,595 1,620 2,640 1,965 4,115 HDI 5/8 2 9 / / ,105 3,105 3,370 3,070 6,450 HDI 3/4 3 3 / / / 8 4,380 4,380 5,570 4,420 9,280 For SI: 1 inch = 25.4 mm, 1 psi = kpa, 1 pound = 4.45 N. 1 The tabulated allowable load values are for anchors installed in normal-weight concrete having the designated ultimate compressive strength at time of anchor installation. 2 The tabulated values are for anchors installed at the specified anchor spacing and concrete edge distance. 3 Concrete edge distance or anchor spacing may be reduced to the minimum edge distances and spacings specified in Table 7 provided the load factors of Table 7 are applied to the tabulated allowable loads. Concrete edge distances for the HDI 1 / 4 -inch anchors installed in concrete with a compressive strength of less than 6,000 psi must not be reduced from those specified in Table 4. 4 When resisting short-term seismic or wind loading, allowable shear loads based on anchor may be increased 11 percent in accordance with Section of the UBC or Section of the IBC. Allowable shear loads based on bolt may be increased 33 1 / 3 percent. 5 Concrete slab thickness must be at least 1.5 times the anchor embedment. Compliance with Section of the UBC or Section of 6 Allowable load must be the lesser of the values based on the anchor and the bolt. TABLE 5 ALLOWABLE TENSION LOADS FOR S INSTALLED IN LIGHTWEIGHT 1,2,3,4,5 (pounds) EDGE ALLOWABLE TENSION (pounds) With Without HDI 1/ / HDI 3/8 1 9 / / / 2 1, HDI 1/ , HDI 5/8 2 9 / / ,405 1,200 HDI 3/4 3 3 / / / 8 3,200 1,600 For SI: 1 inch = 25.4 mm, 1 psi = kpa, 1 pound = 4.45 N, 1 pcf = kg/m 3. 1 The tabulated allowable load values are for anchors installed in structural lightweight concrete having a density of 100 to 115 pcf and a minimum 2 The tabulated values are for anchors installed at the specified anchor spacing and concrete edge distance. 3 Concrete edge distance or anchor spacing may be reduced to the minimum edge distances and spacings specified in Table 7 provided the load factors of Table 7 are applied to the tabulated allowable loads. 4 When resisting seismic or wind loading, allowable tension loads may be increased 33 1 / 3 % in accordance with Section of the UBC or Section of the IBC. 5 Concrete slab thickness must be at least 1.5 times the anchor embedment. Compliance with Section of the UBC or Section of 6 These tension values are only applicable when the anchors are installed with special inspection as set forth in Section 2.5 of this report. 7 These tension values are applicable when the anchors are installed without special inspection.

5 Page 5 of 6 ER-2895 TABLE 6 ALLOWABLE SHEAR LOADS FOR S INSTALLED IN LIGHTWEIGHT 2,3,4,5,6 (pounds) EDGE VALUE BASED ON VALUE BASED ON BOLT 1 ASTM A 307 ASTM A 325 or SAE J 429 Grade 5 HDI 1/ / ,030 HDI 3/8 1 9 / / / 2 1,145 1,105 2,310 HDI 1/ ,040 1,965 4,115 HDI 5/8 2 9 / / ,975 3,070 6,450 HDI 3/4 3 3 / / / 8 4,450 4,420 9,280 For SI: 1 inch = 25.4 mm, 1 psi = kpa, 1 pound = 4.45 N, 1 pcf = kg/m 3. 1 Allowable load must be the lesser of the values based on the anchor and the bolt. 2 The tabulated allowable load values are for anchors installed in structural lightweight concrete having a density of 100 to 115 pcf and a minimum 3 The tabulated values are for anchors installed at the specified anchor spacing and concrete edge distance. 4 Concrete edge distance or anchor spacing may be reduced to the minimum edge distances and spacings specified in Table 7 provided the load factors of Table 7 are applied to the tabulated allowable loads. 5 When resisting short-term seismic or wind loading, allowable shear loads based on anchor may be used, but may not be increased as otherwise permitted by Section of the UBC or Section of the IBC. Allowable shear loads based on bolt may be increased 33 1 / 3 percent. 6 Concrete slab thickness must be at least 1.5 times the anchor embedment. Compliance with Section of the UBC or Section of INSTALLATION DETAILS Minimum anchor spacing TABLE 7 LOAD FACTORS FOR REDUCED S AND EDGE S LOAD FACTORS HDI 1/4 HDI 3/8 HDI 1/2 HDI 5/8 HDI 3/4 Tension Shear / / / Minimum concrete edge 2 distance / / / For SI: 1 inch = 25.4 mm,1 psi = kpa. 1 The tabulated minimum concrete edge distances for the HDI 1 / 4 -inch anchors are only for anchors installed in structural lightweight concrete or in normal-weight concrete having a minimum compressive strength of 6,000 psi. TABLE 8 ALLOWABLE TENSION LOADS FOR S INSTALLED THROUGH STEEL DECK AND INTO LIGHTWEIGHT 1,2,3,4 (pounds) EDGE ALLOWABLE TENSION (pounds) With Inspection 5,7 Without,7 HDI 1/ / HDI 3/8 1 9 / / / HDI 1/ , HDI 5/8 2 9 / / ,995 1,495 HDI 3/4 3 3 / / / 8 3,665 1,830 For SI: 1 inch = 25.4 mm, 1 psi = kpa, 1 pound = 4.45 N, 1 pcf = kg/m 3. 1 This table is for anchors installed in holes drilled through steel having a base-metal thickness of inch and into the concrete. See Figure 3 for typical installation. 2 The tabulated allowable load values are for anchors installed in structural lightweight concrete having a density of 100 to 115 pcf and a minimum 3 The tabulated values are for anchors installed at the specified anchor spacing and concrete edge distance. 4 Concrete slab thickness must be at least 1.5 times the anchor embedment. Compliance with Section of the UBC or Section of 5 These tension values are only applicable when the anchors are installed with special inspection as set forth in Section 2.5 of this report. 6 These tension values are applicable when the anchors are installed without special inspection. 7 Use of the anchors to resist wind or earthquake loads is beyond the scope of this report.

6 Page 6 of 6 ER-2895 TABLE 9 ALLOWABLE SHEAR LOADS FOR S INSTALLED THROUGH STEEL DECK AND INTO LIGHTWEIGHT 1,2, 3, 4, 5 (pounds) EDGE VALUE BASED VALUE BASED ON BOLT 6 ON 6 ASTM A 307 ASTM A 325 or SAE J 429 Grade 5 HDI 1/ / ,030 HDI 3/8 1 9 / / / 2 1,025 1,105 2,310 HDI 1/ ,170 1,965 4,115 HDI 5/8 2 9 / / ,370 3,070 6,450 HDI 3/4 3 3 / / / 8 5,185 4,420 9,280 For SI: 1 inch = 25.4 mm, 1 psi = kpa, 1 pound = 4.45 N. 1 This table is for anchors installed in holes drilled through steel having a base-metal thickness of inch and into the concrete. See Figure 3 for typical installation. 2 The tabulated allowable load values are for anchors installed in structural lightweight concrete having a density of 100 to 115 pcf and a minimum 3 The tabulated values are for anchors installed at the specified anchor spacing and concrete edge distance. 4 Concrete slab thickness must be at least 1.5 times the anchor embedment. Compliance with Section of the UBC or Section of 5 Use of anchors to resist wind or earthquake loads is beyond the scope of this report. 6 Allowable load must be the lesser of the values based on the anchor and the bolt. FIGURE 1 TYPICAL HDI FIGURE 2 TYPICAL SETTING TOOL For SI: 1 inch = 25.4 mm. FIGURE 3 TYPICAL INSTALLED THROUGH METAL DECK INTO LIGHTWEIGHT

LEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER-5608*   Reissued February 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT ER-5608* Reissued February 1, 2004 www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional Office 900 Montclair Road, Suite A, Birmingham,

More information

*Corrected October 2005

*Corrected October 2005 ESR-1056* Reissued December 1, 2004 This report is subject to re-examination in two years. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

ESR ICC Evaluation Service, Inc. Issued March 1, 2006 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Issued March 1, 2006 This report is subject to re-examination in one year. ESR-1328 Issued March 1, 2006 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601

More information

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year. ESR-1967 Reissued January 1, 2008 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 687 (6) 699 0 www.icc es.org ESR 8 Reissued 0/08 This report is subject to renewal 0/09. DIVISION: 0 00 00 MASONRY SECTION:

More information

ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year.

ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year. Reissued November, 008 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office 60 Workman Mill Road, Whittier, California 9060 (6) 699-0

More information

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year. ESR- Reissued September, 00 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 0 Workman Mill Road, Whittier, California 900 #

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588 0 ICC ES Report ICC ES (800) 4 687 (6) 699 04 www.icc es.org 000 Most Widely Accepted and Trusted ESR 06 Valid: 0/ to 0/6 DIVISION: 04 00 00 MASONRY SECTION: 04 0 9.6 MASONRY ANCHORS REPORT HOLDER: SIMPSON

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2966 Reissued 12/2016 This report is subject to renewal 12/2017. DIVISION: 04 00 00 MASONRY

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2966 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 04 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 687 (6) 699 04 www.icc es.org ESR 78 Reissued 07/018 This report is subject to renewal 07/019. DIVISION: 04 00 00 MASONRY

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT PEDRO BIRBA VICE-PRESIDENT VAN AMBATIELOS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA MAYOR

More information

*Corrected, April 2001

*Corrected, April 2001 LEGACY REPORT * Reissued January 1, 2001 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3056 Reissued 10/2015 This report is subject to renewal 10/2017. DIVISION: 04 00 00 MASONRY

More information

To: Firm: Project: Product Specified: Specified Location:

To: Firm: Project: Product Specified: Specified Location: Submittal Substitution Request To: Firm: Project: Product Specified: Specified Location: Attached information includes product description, installation instructions and technical data needed for review

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1678 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 04 00 00 MASONRY

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS GEORGE HOVAGUIMIAN CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 587 (52) 99 0543 www.icc es.org ESR 393 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 04 00 00 MASONRY

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 687 (62) 699 04 www.icc es.org ESR 06 Reissued 0/207 This report is subject to renewal 0/208. DIVISION: 04 00 00 MASONRY

More information

ICC-ES Evaluation Report. ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

ICC-ES Evaluation Report. ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015. A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286 0 ICC-ES Report ICC-ES (800) -687 (6) 6-0 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-678 Reissued 0/0 This report is subject to renewal 0/06 DIVISION: 0 00 00 MASONRY SECTION: 0 0.6 MASONRY

More information

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal May 1, 2015

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal May 1, 2015 [Type text] ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1958 Reissued March 2014 This report is subject to renewal May 1, 2015 A Subsidiary of the International Code Council

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT ER-5000 Reissued January 1, 2007 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3196 Reissued 10/2018 This report is subject to renewal 10/2019. SECTION: 04 05 19.16

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW BUILDEX 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW BUILDEX 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1671 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 04 00

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3833 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 03 00

More information

ESR ICC Evaluation Service, Inc. Reissued July 1, 2006 This report is subject to re-examination in two years.

ESR ICC Evaluation Service, Inc. Reissued July 1, 2006 This report is subject to re-examination in two years. ESR-1178 Reissued July 1, 2006 This report is subject to re-examination in two years. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2254 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 03 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3196 Reissued 10/2017 This report is subject to renewal 10/2018. SECTION: 04 05 19.16

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 42-6587 (562) 699-054 www.icc-es.org ESR-1752 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 0 00 00

More information

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015.

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 4-6587 (56) 699-054 ESR-06 Reissued May, 0 This report is subject to renewal June, 05. A Subsidiary of the International Code Council DIVISION: 0 00 00 CONCRETE

More information

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 3105 Reissued 08/2017 Revised 10/2018 This report is subject to renewal 08/2019.

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS 0 ICC-ES Report ICC-ES (800) 42-6587 (562) 699-054 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-45 Reissued 06/206 This report is subject to renewal 06/207 DIVISION: 0 00 00CONCRETE SECTION:

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued January 1, 2004 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-4143 Issued 01/2018 This report is subject to renewal 01/2019. DIVISION: 04 00 00

More information

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code LEGACY REPORT ER-4203 Reissued June 1, 2004 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office #

More information

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3275 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 03 00

More information

CALIFORNIA ERIC GARCETTI MAYOR

CALIFORNIA ERIC GARCETTI MAYOR BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC SOUTH 122 ND EAST AVENUE TULSA, OKLAHOMA 74146

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC SOUTH 122 ND EAST AVENUE TULSA, OKLAHOMA 74146 0 ICC ES Report ICC ES (800) 42 87 (2) 99 04 www.icc es.org 000 Most Widely Accepted and Trusted ESR 282 Valid: 08/4 to 08/ DIVISION: 04 00 00 MASONRY SECTION: 04 0 9. MASONRY ANCHORS REPORT HOLDER: HILTI,

More information

ICC-ES Evaluation Report Reissued January 1, 2012 This report is subject to renewal in one year.

ICC-ES Evaluation Report Reissued January 1, 2012 This report is subject to renewal in one year. ICC-ES Evaluation Report www.icc-es.org (800) 42-68 (62) 699-04 ESR-2 Reissued January, 202 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION: 04 00

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4264 Issued June 2018 This report is subject to renewal June 2019. DIVISION: 03 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: MITEK USA, INC.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: MITEK USA, INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1702 Reissued 06/2016 This report is subject to renewal 06/2018. DIVISION: 04 00

More information

ESR-2202 Issued May 1, 2009 This report is subject to re-examination in one year.

ESR-2202 Issued May 1, 2009 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2202 Issued May, 2009 This report is subject to re-examination in one year. www.icc-es.org (800) 42-6587 (562) 699-054 A Subsidiary of the International Code Council DIVISION:

More information

ACCEPTANCE CRITERIA FOR FASTENERS POWER-DRIVEN INTO CONCRETE, STEEL AND MASONRY ELEMENTS PREFACE

ACCEPTANCE CRITERIA FOR FASTENERS POWER-DRIVEN INTO CONCRETE, STEEL AND MASONRY ELEMENTS PREFACE ICC EVALUATION SERVICE, INC. Evaluate P Inform P Protect ACCEPTANCE CRITERIA FOR FASTENERS POWER-DRIVEN INTO CONCRETE, STEEL AND MASONRY ELEMENTS AC70 Approved October 2006 Effective January 1, 2007 Previously

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2184 Reissued 06/2017 This report is subject to renewal 06/2019. DIVISION: 03 00

More information

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1530 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 03 00

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1663 Reissued 03/2017 This report is subject to renewal 03/2019. DIVISION: 03 00 00 CONCRETE

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4105 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 04 00 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4042 Issued 07/2017 This report is subject to renewal 07/2018. DIVISION: 04 00 00

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3932 Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 03 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3342 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 04 00

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (00) 42 7 (2) 99 04 www.icc es.org ESR 20 Reissued 11/2017 This report is subject to renewal 11/201. DIVISION: 0 00 00 CONCRETE SECTION:

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-3200 Reissued 12/2017 Revised 10/2018 This report is subject to renewal 12/2018 DIVISION:

More information

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015 0 ICC ES Report ICC ES (800) 42 6587 (562) 699 054 www.icc es.orgg 000 Most Widely Accepted and Trusted ESR 2269 Reissued 02/205 This report is subject to renewal 02/207. DIVISION: 0 00 00 CONCRETE SECTION:

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3200 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 04 00

More information

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3009 Reissued 02/2018 This report is subject to renewal 02/2020. SECTION: 03 16 00

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3251 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 03 00

More information

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2328 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 03 00

More information

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 42-6587 (562) 699-054 www.icc-es.org Most Widely Accepted and Trusted ESR-66 Reissued 0/207 Revised 2/208 This report is subject to renewal 0/209. DIVISION:

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2272 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 03 00

More information

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-2269 Reissued 02/2017 Revised 11/2018 This report is subject to renewal 02/2019.

More information

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 42-687 (62) 699-04 www.icc-es.org ESR-2907 Reissued 2/207 This report is subject to renewal 2/208. DIVISION: 0 00 00 CONCRETE

More information

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 2347 Reissued 12/2017 Revised 09/2018 This report is subject to renewal 12/2019.

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2269 Reissued 02/2017 This report is subject to renewal 02/2019. DIVISION: 03 00

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Listing Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ELC 1917 Reissued 9/2017 This listing is subject to renewal 9/2018. DIVISION: 03 00 00 CONCRETE

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS INTERIM PRESIDENT E. FELICIA BRANNON JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ESR 247 Reissued 2/207 This report is subject to renewal 2/209. DIVISION: 05 00 00 METALS

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued January 1, 2000 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair

More information

Trusted ICC ES HILTI, INC. SYSTEM E ANCHOR. Conformity! Look. Evaluation. ICC-ES Evaluation

Trusted ICC ES HILTI, INC. SYSTEM E ANCHOR. Conformity! Look. Evaluation. ICC-ES Evaluation 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ESR 2682 Reissued 08/2016 This report is subject to renewal 08/2018. DIVISION: 04 00

More information

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS DIVISION: CONCRETE ANCHORS REPORT HOLDER: DEWALT

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS DIVISION: CONCRETE ANCHORS REPORT HOLDER: DEWALT 0 Most Widely Accepted and Trusted ICC ES Listing Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ELC 3657 Issued 05/2017 This listing is subject to renewal 05/2018. DIVISION: 03 00 00 CONCRETE

More information

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2347 Reissued 12/2015 This report is subject to renewal 12/2017. DIVISION: 05 00 00 METALS SECTION:

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW RED HEAD 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW RED HEAD 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (00) 423-657 (562) 699-0543 www.icc-es.org ESR-4109 Issued 09/2017 This report is subject to renewal 09/201. DIVISION: 04 00 00 MASONRY

More information

ESR-2713 Reissued August 1, 2013 This report is subject to renewal September 1, 2014.

ESR-2713 Reissued August 1, 2013 This report is subject to renewal September 1, 2014. ICC-ES Evaluation Report www.icc-es.org (800) 42-8 (2) 99-04 ESR-2 Reissued August, 20 This report is subject to renewal September, 204. A Subsidiary of the International Code Council DIVISION: 0 00 00

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Listing Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESL 1067 Reissued 09/2017 This listing is subject to renewal 09/2018. DIVISION: 03 00 00

More information

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3788 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 04 00

More information

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry TITEN HD Heavy Duty Screw Anchor for & Masonry The Titen HD is a patented, high-strength screw anchor for concrete and masonry. The self-undercutting, non-expansion characteristics of the Titen HD makes

More information

Trusted ICC ES CONCRETE SECTION: SECTION: 05 HILTI, INC. Look. Conformity! ICC-ES Evaluation

Trusted ICC ES CONCRETE SECTION: SECTION: 05 HILTI, INC. Look. Conformity! ICC-ES Evaluation 0 Most Widely Accepted and Trusted ICC ES Listing Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ELC 1917 Reissued 09/2018 This listing is subject to renewal 09/2019. DIVISION: 03 00 00

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS SEPAND SAMZADEH CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR DEPARTMENT

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued October 1, 2007 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3981 Issued 10/2017 This report is subject to renewal 10/2018. DIVISION: 03 00 00

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3852 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 03 00 00 CONCRETE

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS SECTION: PRECAST STRUCTURAL CONCRETE SECTION: SITE CAST CONCRETE

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS SECTION: PRECAST STRUCTURAL CONCRETE SECTION: SITE CAST CONCRETE 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2873 Issued 09/2017 This report is subject to renewal 09/2018. DIVISION: 03 00 00

More information

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: DEWALT

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: DEWALT 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3657 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 03 00

More information

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California Reissued June 1, 2002 ICBO Evaluation Service, Inc. 5360 Workman Mill Road, Whittier, California 90601 www.icboes.org Filing Category: DESIGN Concrete DURISOL WALL FORMS FOR CONCRETE CONSTRUCTION DURISOL

More information

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1729 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 05 00 00 METALS SECTION:

More information

DIVISION: CONCRETE SECTION: CAST-IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC.

DIVISION: CONCRETE SECTION: CAST-IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-4145 Issued 02/2018 This report is subject to renewal 02/2019. DIVISION: 03 00 00

More information

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038) ICBO Evaluation Service, Inc. 5360 WORKMAN MILL ROAD WHITTIER, CALIFORNIA 90601-2299 A subsidiary corporation of the International Conference of Building Officials EVALUATION REPORT Copyright 2001 ICBO

More information

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2787 Reissued 05/2017 This report is subject to renewal 05/2019. DIVISION: 03 00

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT VAN AMBATIELOS VICE-PRESIDENT VICTOR H. CUEVAS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: MASON WEST, INC.

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: MASON WEST, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3443 Issued 04/2017 This report is subject to renewal 04/2018. DIVISION: 03 00 00

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS SEPAND SAMZADEH CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 43 6587 (56) 699 0543 www.icc es.org ESR 3754 Reissued 09/07 This report is subject to renewal 09/09. DIVISION: 03 00 00 CONCRETE

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3772 Reissued 10/2017 This report is subject to renewal 10/2019. DIVISION: 03 00

More information

where: P s = Applied service tension load, pounds (kg). P t V s V t

where: P s = Applied service tension load, pounds (kg). P t V s V t Æ Æ Æ Æ Æ Æ Æ Æ Æ ESR-1752 Most Widely Accepted and Trusted Page 2 of 7 3.1.7 X-S16P8TH: The X-S16P8TH fastener is a powder actuated fastener for installation into steel. It has a shank diameter of 0.145

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 2 687 (62) 699 0 www.icc es.org ESR 067 Reissued 06/208 This report is subject to renewal 06/209. DIVISION: 0 00 00 CONCRETE

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS GEORGE HOVAGUIMIAN CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2047 Reissued 07/207 This report is subject to renewal 07/209. DIVISION: 05 00 00

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT VAN AMBATIELOS VICE-PRESIDENT VICTOR H. CUEVAS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3068 Reissued 07/2018 This report is subject to renewal 07/2019. DIVISION: 03 00

More information