Healing the Hurt: Hurricane Restoration

Size: px
Start display at page:

Download "Healing the Hurt: Hurricane Restoration"

Transcription

1 Healing the Hurt: Hurricane Restoration a presentation by: George M. Fletcher President/CEO Adache Group Architects, Inc. Ft. Lauderdale and Pensacola, FL

2 Healing the Hurt The past couple of hurricane seasons sparked media frenzy and news outlets questioning the effectiveness of building codes in providing adequate standards for hurricane protection. Since most of the weather prognosticators have indicated that the trend for the next decade will bring more storms, you need to be informed and kept updated on what can be done in construction and renovations now and in the future. Following these hard hitting hurricane events, Gulf coast states have moved to modify building code standards in an effort to minimize the damage caused by future storms. But, how can you, as a builder, move in the right direction to provide a residential product with a more hurricane resistant structure? The following is a brief summary of building methods and materials available to promote awareness. It is important to remember that building codes are just minimum protection to save lives, not the maximum. It is our responsibility as architects, builders, insurers, legislators and owners to become more aware of the specification of certain products. This will not only help save lives and property, but also can help protect local, regional and national economies. As builders begin working on projects in hurricane prone areas, it will become increasingly important to understand the abilities and possibilities of hurricane resistant products. Even if some building codes don t currently require stronger and more durable products, it is anticipated many building owners will move in that direction. These tips are the future of the construction industry in high risk areas, and builders must have the knowledge and ability to meet this demand. For more information, please contact us and we can assist in leading you in the right direction Adache Group Architects, Inc. 550 South Federal Highway. Ft. Lauderdale, FL

3 Protective Openings Doors and windows are vulnerable components of your homes protective shell or envelope because they are easily penetrated by wind-borne debris often generated by the high winds of storms like hurricanes. The Federal Emergency Management Agency (FEMA) has identified the loss of the garage door as one of four major factors in homes damaged and destroyed in hurricanes. If that envelope is breached during a storm because of the failure of windows and doors, wind, wind-driven rain and debris can enter your home causing considerable damage to its interior and your property.. A more critical issue develops when the envelope is breached -- high winds can enter your home and exert high pressure on your walls and roof. These internal pressures combined with the external pressure of wind blowing over your home can lead to catastrophic damage.. You can protect your home's openings by installing impact-resistant windows and doors or installing impact resistant coverings, such as shutters over windows and doors. Impact resistant glass and shutters are specifically designed to meet a combination of impact and continuous pressure from the wind. Always use products that have been tested to one of these standards and have been designated as such through a recognized product approval system or evaluation report. Ft. Lauderdale, FL Pensacola, FL

4 Foundation & Wall Construction There are several types of foundations used in residential construction but all have one important requirement the foundation and connections to the walls and floors must be strong enough not only to support the weight of the house and its contents, but also to prevent the home from being blown away by high winds. There are many construction techniques for anchoring the exterior walls to the foundation. For wood-framed construction, the bottom plate of the wall should be anchored into the slab with anchor bolts and washers. The bottom plate should be securely connected to the wall studs above by using approved metal clips or straps. For concrete masonry construction, vertical reinforcement in a continuously grouted cell should extend from the wall above and be embedded in the concrete footing below with a standard hook. A stemwall is a concrete block or brick wall used on top of the footer for off grade houses where the ground slopes from one side to the other. Ft. Lauderdale, FL Pensacola, FL

5 Roof Construction Taken as a whole, these recommendations will help builders build storm-resistant roofs in areas that are at a high-risk for being hit by strong winds. Most of them add minimal additional costs to the finished cost of a roof. Many of these recommendations should even be used on homes outside of the hurricane region. Guidelines: 1. Moderately pitched hips rather than gables 2. OVE structural members for roof truss components or engineered wood girders 3. Install hurricane straps to load bearing components 4. Use baffled ridge and soffit vents to minimize the number of roof penetrations 5. Extend fascia board so it terminates below the underside of the soffit 6. Securely attach grid-marked sheathing of appropriate thickness 7. Tape decking seams with a self-adhering bitumen tape or peel and stick roof membrane 8. Install underlayment correctly 9. Use proper flashing and starter strips techniques 10. Install a light-colored wind and impact resistant roof covering 11. Use proper fastener/nailing schedules Ft. Lauderdale, FL Pensacola, FL

6 Minimum Flood Criteria Rain. Hurricanes. Tides. Levee failure. Floods happen, and they happen beside rivers, on the coast, in deserts and in city streets. You don't have to lose your home and possessions to rampaging waters, however. It's never too early to prepare and you can take several basic steps right now to protect your family and your home from disaster. Guidelines: Use water-resistant building materials in areas below the base flood elevation. Leave the basement or lower floors unfinished if they're below base flood elevation. Prevent sewer lines from backing up by installing backflow valves or standpipes. Raise your washer and dryer and other equipment such as the water heater, oil tanks, furnace and electrical wiring on concrete blocks, above the base flood elevation level. If you are unable to raise a particular item, consider anchoring it and protecting it with a floodwall or shield. Install flood shields or built-up barriers for basement windows and doors. The tops of shields and barriers should extend above the base flood elevation. Install and maintain a sump pump system if you have below-grade floors. Landscape with native plants and vegetation that resist soil erosion. Ft. Lauderdale, FL Pensacola, FL

7 Safe Room Protection from tornadoes, hurricanes and whatever else Mother Nature wants to throw at you. TYPES: Above Ground Below Ground Interior Exterior Walk-in Vault Panic Room Safe Rooms Becoming popular Storm Shelter choices GUIDELINES: Resist 15 pound 2 x 4 boards impacting at velocity of 100 mph Resist the impacts of full sized automobiles dropped from 30 feet above roof Resist 38 cal. 357 magnum (full metal jacket) and 45 cal. small arms fire at 15 feet Resist the impact of a 50 foot, 18 inch diameter hickory tree on the roof Resist the impact of a 2.5 ton steel junk yard magnet impacting the wall at 30 mph Ft. Lauderdale, FL Pensacola, FL

8 Power Generation When a natural disaster such as a hurricane occurs, backup power is an absolute necessity. When hurricanes strike, the damage to power lines can be so severe, that it can literally take months before power is completely restored. That s why having a backup power plan is a definite must have. When the power goes out, there is no more hot water source whatsoever. When a hurricane strikes, the importance of backup power can never be overemphasized. It can save lives and make dealing with such a disaster much more bearable as well as making day-today life more tolerable. Guidelines: clearly identify all circuits on your electrical panels make sure you run it at the correct RPM (540 or 1000 RPM); never assume the tractor RPM is correct running a generator faster will not produce more power, but it may damage it make sure the PTO shaft is designed for the horsepower required follow the information on the plate on the side of the generator disconnect all loads before starting, including hot water heaters, heating cables, heated water troughs; reconnect them slowly after essential motors are running turn on the motors one at a time generators may handle short term heavy loads, but may not for long periods monitor voltage and keep 240 V (± 10%) at the generator for continuous operation, try to run the system at 80% capacity or less, if possible use an amp-meter to check total loading and compare it to the generator's specifications if the circuit breaker on the generator trips, reduce the loading and make sure your 120 V loads are balanced; if more loads come from one side of the fuse box, they should be shut off to balance the load; remember the generator does not average loads, but trips on the highest loading from one side keep fuel on hand for at least 72 hours Ft. Lauderdale, FL Pensacola, FL

9 Generators which system to use Your electric needs Furnace Fan Refrigerator/ Freezer Sump Pump Lighting Well Pump Television/R adio Computer Home Ventilation Fan Garage Door Opener Electric Range Water Heater Security System Central Air System Washing Machine Microwave Oven Clothes Dryer Dishwasher Vacuum Cleaner Toaster Oven Humidifier Wine Cellar Extensive Power Requirements Copyright Norwall PowerSystems

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not

More information

Protecting YOUR EXISTING HOME FROM Wind Damage

Protecting YOUR EXISTING HOME FROM Wind Damage Protecting YOUR EXISTING HOME FROM Wind Damage Blueprint for Safety... A Blueprint for Life When severe weather threatens, protecting life and property automatically becomes top priority for millions of

More information

Builders, Realtors, Roofers and Yourself

Builders, Realtors, Roofers and Yourself What to Ask Builders, Realtors, Roofers and Yourself About Protecting Your Home from Hurricanes, High Winds and Hail. Texas Department of Insurance Asking the following questions will help protect your

More information

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits 3. Development and Septic Fees 4. Tarion New Home Warranty

More information

STRUCTURAL DESIGN CRITERIA

STRUCTURAL DESIGN CRITERIA CHAPTER 3 STRUCTURAL DESIGN CRITERIA SECTION 301 GENERAL 301.1 Scope. Loads and load combinations shall be determined in accordance with ASCE 7 unless otherwise noted. Structural elements of the storm

More information

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

CODE COMPLIANCE GUIDELINE GENERAL BUILDING CODE COMPLIANCE GUIDELINE This guideline has been prepared by The Calhoun County Building Department to assist Homebuilders, General Contractors, and Owner/Builders during the construction process. The

More information

Why FORTIFIED? Tier 1: FORTIFIED Bronze. FORTIFIED Silver. Tier 2: FORTIFIED Gold

Why FORTIFIED? Tier 1: FORTIFIED Bronze. FORTIFIED Silver. Tier 2: FORTIFIED Gold The goal of the FORTIFIED for Existing Homes program is to strengthen your home against specific regional natural hazards through a retrofitting process. Depending on the natural hazard, the program may

More information

Town of Pawling Residential Building Permit Application

Town of Pawling Residential Building Permit Application Town of Pawling Residential Building Permit Application Property Address: Street: City: Zip: Grid Number: Zoning District: Project Description: Owners Name: Phone: (H) (W) Address: Street: City: State:

More information

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall GROUNDS Grading General Grading, slope and drainage: Satisfactory Grading and slope at house wall Satisfactory (within 5 feet from building) Sidewalk Concrete Brick Flagstone Other Patio stones Driveway

More information

1 BASE HOME CONSTRUCTION SPECIFICATIONS: TOWNHOMES 5-13-2015 Note: Specifications noted below may change based on selected options. Verify upgrades from the base specifications with the option sheets and

More information

Protect Your Home from Flooding LOW-COST PROJECTS YOU CAN DO YOURSELF

Protect Your Home from Flooding LOW-COST PROJECTS YOU CAN DO YOURSELF Protect Your Home from Flooding LOW-COST PROJECTS YOU CAN DO YOURSELF FLOODING IS THE MOST COMMON AND COSTLY DISASTER IN THE UNITED STATES AND CAN HAPPEN ANYWHERE. However, there are many ways to reduce

More information

Town of Pawling Residential Building Permit Application

Town of Pawling Residential Building Permit Application Town of Pawling Residential Building Permit Application Property Address: Street: City: Zip: Grid Number: Zoning District: Project Description: Owners Name: Phone: H W/C Address: Street: City: State: Zip:

More information

DESIGNING SAFE ROOMS AND SAFE HOMES WITH LOGIX.

DESIGNING SAFE ROOMS AND SAFE HOMES WITH LOGIX. . Actual ICF-Built Home That Survived Katrina Table of Contents Section Page Overview Logix Wind Resistance Advantages...3 Logix Wall Engineering To 300 MPH Wind Rating...6 Fema-Compliant Design Specifications

More information

NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003)

NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003) NCM TEK National Concrete Masonry ssociation an information series from the national authority on concrete masonry technology RESIDENTIL DETILS FOR HIGH WIND RES TEK 5-11 Details (2003) Keywords: architectural

More information

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION Town of Hague Building Inspector: Dale Wagner Home #: 306-225-2265 Cell #: 306-241-4741 Fill all part of the permit application including the date and signature.

More information

City of Oviedo Residential Permit Application Guidelines

City of Oviedo Residential Permit Application Guidelines City of Oviedo Residential Permit Application Guidelines All permit applications must be complete prior to acceptance. A complete application shall include the following: Building Permit Application completed,

More information

STRUCTURAL DESIGN CRITERIA

STRUCTURAL DESIGN CRITERIA CHAPTER 3 STRUCTURAL DESIGN CRITERIA SECTION 301 GENERAL 301.1 Scope. Loads and load combinations shall be determined in accordance with ASCE 7 unless otherwise noted. Structural elements of the storm

More information

Inspection Report. Property Address:

Inspection Report. Property Address: Inspection Report provided by: Safe Side Home Inspection Inspector: Corey Stuart TN License # 778 434 Margaret Circle McMinnville, TN 37110 safesideinspection@blomand.net Property Address: 1234 Anywhere

More information

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section ) 8-1200. International Residential Code. ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section 6-9-40) NOTE-This article

More information

Hurricane- Resistance. designations: WHY FORTIFIED? DESIGNATION PROCESS

Hurricane- Resistance. designations: WHY FORTIFIED? DESIGNATION PROCESS Hurricane- Resistance Designation The goal of the FORTIFIED for Existing Homes program is to strengthen your home against specific regional natural hazards through a retrofitting process. Depending on

More information

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) PERMIT SUBMITTAL CHECKLIST: Signed completed Building Permit application form. Two (2) Copies of a Certificate of Survey. Draw to scale the

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire Additional Instructions and Clarifications 1. Please review ARC 4496 before beginning the project identification

More information

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public

More information

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches and shall be sized to carry the applicable roof and

More information

Z & C Construction, Inc. Subdivision:

Z & C Construction, Inc. Subdivision: : Buyer(s): Address: Lot: Block: Model: Subdivision: A. Foundations Unfinished basement or crawlspace included per buyer selection (extra fees may apply) Engineered concrete foundation Perimeter drainage

More information

Elko County Building & Safety Division

Elko County Building & Safety Division Elko County Building & Safety Division 540 Court St., Suite 104, Elko, Nevada 89801 (775) 738-6816, Fax (775) 738-4581 www.elkocountynv.net Residential Design Criteria & Checklist One & Two Family Dwellings

More information

RESIDENTIAL RE-ROOFING PERMIT APPLICATION

RESIDENTIAL RE-ROOFING PERMIT APPLICATION RESIDENTIAL RE-ROOFING PERMIT APPLICATION Effective date: October 1, 2007. Note: These requirements apply to residential structures built prior to implementation of the FBC on March 1, 2002. I. LEGAL DESCRIPTION:

More information

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested. Purpose 355 West Queens Road Single Family New Construction Required Inspection Stages Master Requirement GEN 110 Building Department: 604-990-2480, building@dnv.org, fax: 604-984-9683 The following procedure

More information

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:

More information

RESIDENTIAL BUILDING PLAN REQUIREMENTS

RESIDENTIAL BUILDING PLAN REQUIREMENTS CITY OF MANSFIELD BUREAU OF BUILDING AND CODES 30 NORTH DIAMOND STREET 3RD FLOOR MANSFIELD, OHIO 44902 Phone (419) 755-9688 Fax (419) 755-9453 www.ci.mansfield.oh.us RESIDENTIAL BUILDING PLAN REQUIREMENTS

More information

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free / / Paperport 2000 official estimating report Work Write Up / Specification of Repairs Toll Free 1-877-932-7177 Clients Name. GREAT CLIENT Property Address. NUMBER ONE GOOD ROAD METRO, VA 20000 Primary

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

PLANNING FOUNDATION FRAMING

PLANNING FOUNDATION FRAMING TRITON MODEL 3208 Chiquita Blvd. S. #208 Cape Coral, FL 33914 (239) 549-5554 CBC 1259879 What s Included in a Poseidon Home PLANNING Provide all permits necessary to comply with local codes Provide all

More information

Above the Flood: Elevating Your Floodprone House. FEMA 347/ May 2000 FEMA

Above the Flood: Elevating Your Floodprone House. FEMA 347/ May 2000 FEMA Above the Flood: Elevating Your Floodprone House FEMA 347/ May 2000 FEMA Cover photograph provided by The Weather Channel. Table of Contents Chapter 1 Introduction...1-1 Chapter 2 Homeowner Options...2-1

More information

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507) Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed

More information

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following:

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following: New buildings or renovations to existing buildings for which an application for a permit was made to the Department or a municipality before April 9, 2004. New buildings or renovations to existing buildings

More information

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal Roof Size: Width: Length: Roof Type: Gable: Hip: Shed: Roof Pitch: (check one) Trusses: Rafters: Spacing of Trusses or Rafters:

More information

Florida Building Code 6th Edition (2017) High-Velocity Hurricane Zone Uniform Permit Application Form

Florida Building Code 6th Edition (2017) High-Velocity Hurricane Zone Uniform Permit Application Form Are there Gas Vent Stacks? Yes No Type: Natural LPGX FBC SECTION 1524 HIGH-VELOCITY HURRICANE ZONES REQUIRED OWNER S NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section,

More information

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321) BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL 32907 Phone: (321) 953-8924 Fax: (321) 953-8925 CUSTOMER SERVICE INFORMATION ON RESIDENTIAL PLAN REVIEW REQUIRED DOCUMENTS MUST BE SUBMITTED AT TIME

More information

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION Permit No. 175 Beaver Drive, P.O. Box 486 DuBois, PA 15801 Phone: 814-375-1111 Fax: 814-375-1117 Toll Free: 855-PENNSAF LOCATION OF PROPOSED

More information

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321) BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL 32907 Phone: (321) 953-8924 Fax: (321) 953-8925 CUSTOMER SERVICE INFORMATION ON COMMERCIAL PLAN REVIEW REQUIRED DOCUMENTS MUST BE SUBMITTED AT TIME

More information

The Inspection Process. Waxhaw N.C.

The Inspection Process. Waxhaw N.C. The Inspection Process In Waxhaw N.C. This information is provided by the Waxhaw Enforcement Division to assist you in the progression of your project. Nothing in this document should be considered "Code"

More information

component was performing its intended function; installation and condition were appropriate for age and use.

component was performing its intended function; installation and condition were appropriate for age and use. April 23, 2012 Dear Home Seller, On April 6, 2012, Cities Inspection Service, Inc. completed a home inspection of the property located at 123 Oak Drive, Somewhere, Minnesota for you. Doug Hastings did

More information

Building Guide. Colorado Chapter of the International Code Council

Building Guide. Colorado Chapter of the International Code Council 12/29/16 Building uide Colorado Chapter of the International Code Council How to Use this uide Check with your jurisdiction regarding type of submittal (paper or electronic) and for additional requirements.draw

More information

NC 2009 Residential Code changes (Highlights on changes between the 2006 and 2009 NC Residential Code)

NC 2009 Residential Code changes (Highlights on changes between the 2006 and 2009 NC Residential Code) NC 2009 Residential changes (Highlights on changes between the 2006 and 2009 NC Residential ) Chapters 1 and 2: Administration and Definitions Section Title R101.2 Scope Added the words ABOVE GRADE. R101.5

More information

7 NON-STRUCTURAL ELEMENTS

7 NON-STRUCTURAL ELEMENTS Non-Structural Elements 85 7 NON-STRUCTURAL ELEMENTS Edited by Timothy P. McCormick, P.E. 86 Non-Structural Elements Non-Structural Elements 87 NON-STRUCTURAL ELEMENTS CHIMNEYS The first nonstructural

More information

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST Village of Vernon Hills Community Development Department - Building Division 290 Evergreen Drive, Vernon Hills, IL 60061 Phone 847-367-3704 - Fax 847-367-2541 - http://www.vernonhills.org INSPECTION TIMING

More information

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048 Home Inspection Grant 7142 21st Street Omaha, NE 68048 Page 1 of 13 Table of Contents Definitions 2 General Information 2 Roof 3 Exterior 4 Grounds 5 Attic 5 Garage 6 Bathroom 6 Interior 7 Kitchen 7 Laundry

More information

City of Pembroke Pines 601 City Center Way, Pembroke Pines, FL Tel# Fax# Cover Sheet for Permits Submitted Online

City of Pembroke Pines 601 City Center Way, Pembroke Pines, FL Tel# Fax# Cover Sheet for Permits Submitted Online City of Pembroke Pines 601 City Center Way, Pembroke Pines, FL 33025 Tel#954-435-6502 Fax#954-435-6749 Cover Sheet for Permits Submitted Online All permits Submitted online Must include this completed

More information

ADDENDUM A CONSTRUCTION SPECIFICATIONS

ADDENDUM A CONSTRUCTION SPECIFICATIONS ADDENDUM A Description of Improvements: CONSTRUCTION SPECIFICATIONS The Improvements shall consist of constructing an approximate square foot single-family residence including car garage on the real property

More information

"Nuts & Bolts How fast can wind destroy a home? Simple construction tips to keep yours standing

Nuts & Bolts How fast can wind destroy a home? Simple construction tips to keep yours standing "Nuts & Bolts How fast can wind destroy a home? Simple construction tips to keep yours standing The 23 rd Advanced Severe Weather Seminar March 15, 2014 Gone in Seconds 95 mph Straight Line Winds EF-2

More information

Inspection Report. 1 of 8

Inspection Report. 1 of 8 Inspection Report Dayvolt's Home Inspections L.L.C. Date&Time of Inspection: 5/9/17, 12:10 PM Inspector's Name: Dustin Dayvolt Building Address: Sample City: State: Zip Code: Type of property inspected:

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

ACP Greater Tampa Bay Mitigation as a Precursor to Recovery

ACP Greater Tampa Bay Mitigation as a Precursor to Recovery . ACP Greater Tampa Bay Mitigation as a Precursor to Recovery Wednesday, September 25, 2013 Chuck Miccolis Commercial Lines Engineer URL to Previous Slide s Video http://vimeo.com/60451146 How does IBHS

More information

Investigation of Wind Projectile Resistance of Insulating Concrete Form Homes. by Ernst W. Kiesling, Ph.D., P.E. Russell Carter, BSCE, EIT

Investigation of Wind Projectile Resistance of Insulating Concrete Form Homes. by Ernst W. Kiesling, Ph.D., P.E. Russell Carter, BSCE, EIT Investigation of Wind Projectile Resistance of Insulating Concrete Form Homes by Ernst W. Kiesling, Ph.D., P.E. Russell Carter, BSCE, EIT R E S E A R C H & D E V E L O P M E N T B U L L E T I N RP122 Investigation

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

Country Village Maintenance Responsibility Guidelines BUILDING - EXTERIORS AND INTERIORS

Country Village Maintenance Responsibility Guidelines BUILDING - EXTERIORS AND INTERIORS BUILDING - EXTERIORS AND INTERIORS Building Interior / Framework Blocking Braces Foundation and Interior Slab Rafters Ridge Boards Studs Trusses Internal portion of exterior walls & roofing (i.e. interior

More information

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE - 268-5161 Residential Accessory Structures This information has been compiled for the benefit of any person

More information

4 Structural Performance

4 Structural Performance Section 4 STRUCTURAL PERFORMANCE 4 Structural Performance The BPAT inspected the structural performance of three primary construction types: reinforced concrete, reinforced masonry, and wood-frame. Inspections

More information

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department olorado Chapter of the International Conference of Building Officials Lancaster County Building Department Single Family Residential One Story Detached Garage How to Use this Guide Provide two sets of

More information

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems Architectural asphalt shingles and horizontal True Wood 7" Reveal siding over structural panel. Nailing schedule is 6" on ends 12" on centers 6d nails. Trusses are engineered on Bonus attic trusses 24"

More information

One & Two Family Residential ADDITIONS

One & Two Family Residential ADDITIONS City of St. Petersburg Development Services One & Two Family Residential ADDITIONS (Effective Date: 5/1/03) This checklist is subject to change and improvement at any time. Please determine that you have

More information

ACCESSORY BUILDING. Building Permit Requirements: (must be completed before submitting application)

ACCESSORY BUILDING. Building Permit Requirements: (must be completed before submitting application) ACCESSORY BUILDING Before your application can be deemed complete and ready for processing you will need the following: (Please hand in entire application package including this cover sheet) Zoning- check

More information

UCC Permit Application Procedures

UCC Permit Application Procedures How do I apply for a permit? UCC Permit Application Procedures 1. Please complete the CodeMaster Pan Review Application 2. Please provide the scope of work description and/or construction documents/plans.

More information

SPECIALTY STRUCTURE CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

SPECIALTY STRUCTURE CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT) format. It will consist of 80 equally weighted questions. The examination will have questions

More information

Know the Difference Basement or Elevated

Know the Difference Basement or Elevated October, 2013 Know the Difference Basement or Elevated This session is for education purposes only NO Continuing Education credits will be provided Please note: These materials may become dated as NFIP

More information

The Homeowner s Building Application Checklist for Constructing a Residential Addition

The Homeowner s Building Application Checklist for Constructing a Residential Addition The Homeowner s Building Application Checklist for Constructing a Residential Addition This checklist provides homeowners a summary of the Building Permit submission requirements for constructing a residential

More information

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International Building Guide Colorado Chapter of the International Conference of Building Officials Colorado Building Chapter of the International Guide Code Council Single Family Residential One Story Detached Garage

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge

More information

1 AND 2 FAMILY DWELLING REQUIREMENTS

1 AND 2 FAMILY DWELLING REQUIREMENTS PLAN REQUIREMENTS: 1 AND 2 FAMILY DWELLING REQUIREMENTS All residential plans including additions and attached garages shall be designed to the current edition of the International Residential Code. Plans

More information

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory

More information

SINGLE FAMILY HOME SPECIFICATIONS

SINGLE FAMILY HOME SPECIFICATIONS SINGLE FAMILY HOME SPECIFICATIONS GENERAL Lot is included in the price Home is registered with TARION warranty Program (www.tarion.com) TARION registration fee included Builder pays associated Government

More information

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012 Inspection Report Prepared for: Tonia Mann Property Address: Dacula, GA 30019 Date: March 01, 2012 Inspector: Charles Mann (770) 594-2222 www.edificeinspections.com Page 1 INSPECTION CONDITIONS CLIENT

More information

- Inbound/Outbound window placement - Window buck & air sealing - Weep holes IN THE WOODS DETAILS - WINDOW SILL

- Inbound/Outbound window placement - Window buck & air sealing - Weep holes IN THE WOODS DETAILS - WINDOW SILL - Inbound/Outbound window placement - Window buck & air sealing - Weep holes IN THE WOODS DETAILS - WINDOW SILL PRE-EXISTING SITE Program: Traditional farmhouse Single level living potential Garage connection

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist

One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist City of St. Petersburg Development Services One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist (Effective Date: 5/1/03) This checklist is subject to change and improvement at any time.

More information

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction. Plan Examination 1 Plan ExaminationPurpose 2 Catch problems in advance of construction. 3 1 Discovery of problems in the field results in higher cost. 4 Can a good plan review eliminate all problems in

More information

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

RESIDENTIAL CONSTRUCTION New Dwellings and Additions How to Obtain a Building Permit For RESIDENTIAL CONSTRUCTION New Dwellings and Additions MIAMI COUNTY, KANSAS CODE SERVICES DEPARTMENT 201 South Pearl Street, Suite 201 Paola, Kansas 66071-1777 Phone:

More information

FIELD COPY ATTACHMENT

FIELD COPY ATTACHMENT FIELD COPY ATTACHMENT The released plans for the project must be on site and available to the inspectors at all times. No inspection will be done without the released field plans. If you have any questions,

More information

FOUR CORNERS CUSTOM BUILDERS, LLC

FOUR CORNERS CUSTOM BUILDERS, LLC TEMPLE Tier 2 Four Corners Custom Builders, LLC 146 Fredericksville Road Mertztown, PA 19539 (610) 682-0758 info@fourcornerscb.com www.fourcornerscb.com PA128784 TEMPLE PRICE: $169,900 SERIES: Tier 2 TYPE:

More information

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY The list below contains those building elements most commonly found in buildings found in a condominium

More information

ABOVEGROUND HOME FALLOUT SHELTER H-12-2 / November 1983 (Supercedes H-12-2 dated June 1980)

ABOVEGROUND HOME FALLOUT SHELTER H-12-2 / November 1983 (Supercedes H-12-2 dated June 1980) ABOVEGROUND HOME FALLOUT SHELTER H-12-2 / November 1983 (Supercedes H-12-2 dated June 1980) Page 1 General Information This family shelter is intended for persons who prefer an aboveground shelter or,

More information

A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION

A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION PLEASE TE: This Summary is for convenience of reference only. It does not supersede or alter

More information

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY The list below contains those building elements most commonly found in buildings found in a condominium

More information

Pulaski County, Virginia Practical Wall Bracing

Pulaski County, Virginia Practical Wall Bracing Pulaski County, Virginia Practical Wall Bracing Based on the 2012 Virginia Residential Code The information herein provides guidelines for complying with the most common Practical Wall Bracing provisions

More information

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0 3'-0 1'-0 14'-0 14'-0 1'-0 6'-0 3'-0 10'-0" BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. BARN TO BE BUILT AS PER LOCAL CODE REQUIREMENTS 14'-0" BWP BWP BWP ABWP 101

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge

More information

Borough of Doylestown Building and Zoning Department

Borough of Doylestown Building and Zoning Department Borough of Doylestown Building and Zoning Department 57 West Court Street, Doylestown, PA 18901 215.345.4140 RESIDENTIAL BUILDING AND ZONING PERMIT APPLICATION PACKAGE BACKGROUND A building permit is required

More information

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 6114 Robert Wayne Dr, Pasco, WA

More information

RESIDENTIAL DETACHED ACCESSORY STRUCTURES

RESIDENTIAL DETACHED ACCESSORY STRUCTURES RESIDENTIAL DETACHED ACCESSORY STRUCTURES *A Building permit is required for any alteration or addition to any existing building or structure. MN State Building Code Section 1300.0120 Subpart 1 Permit

More information

Chapter 2: Foundation

Chapter 2: Foundation Chapter 2: Foundation Crawlspace [V502.1.2] [V502.1.2] [V502.1.3] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup

More information

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC) Plan Check Submittal Date: Plan Check #: Permit App.# Job Address: Applicant: Phone: ( ) Plan Check Engineer:

More information

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT MOSHANNON VALLEY COUNCIL OF GOVERNMENTS 501 E. MARKET STREET SUITE 7 CLEARFIELD, PA 16830 814-765- 3080 1. ITEMS TO SUBMIT: A. COMPLETED AND SIGNED APPLICATION B. SIGNED PRIOR MUNICIPAL APPROVAL PAGE C.

More information

Using Building Science to Reduce Weather-Related Losses Greater Tampa Bay ACP Chapter Meeting May 30, 2012

Using Building Science to Reduce Weather-Related Losses Greater Tampa Bay ACP Chapter Meeting May 30, 2012 Using Building Science to Reduce Weather-Related Losses Greater Tampa Bay ACP Chapter Meeting May 30, 2012 Chuck Miccolis IBHS Commercial Lines Engineer & Gail Moraton IBHS Business Resiliency Manager

More information

Steps in Building a Shed

Steps in Building a Shed Steps in Building a Shed The design and location of your new shed will depend on how it will be used - a shed for storing tools will be much simpler than one you intend to use as a small shop. For example,

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15 CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15 Copyright 2004 CONSTRUCTION The following are twenty key construction components and basic facts that are to be considered high priority. Please refer

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN 30 year dimensional shingles and Metal Verticle siding over structural sheathing. Nailing schedule is " on ends 12" on centers d nails. Trusses are engineered on 24" and framing is 2" x " on 1" centers.

More information

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS St. Louis County Department of Public Works Division of Code Enforcement HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS This guide is intended to provide the homeowner or contractor with the

More information