CENTRIA FORMABOND. Aluminum Composite Wall System

Size: px
Start display at page:

Download "CENTRIA FORMABOND. Aluminum Composite Wall System"

Transcription

1 CENTRIA FORMABOND Aluminum Composite Wall System CENTRIA FormaBond is the only true aluminum composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer and supported by an experienced installer network, ready to install right from the factory. FormaBond is fabricated into lightweight finished panels, complete with dry rout-and-return panel joinery and stiffeners. The FormaBond Wall System provides high-performance drained and back-ventilated rainscreen design. CENTRIA's patent-pending dry joinery eliminates unsightly wet seals and provides optimum venting to allow wall cavities to dry effectively while prohibiting the entry of rain water, thus reducing the chance of entrapped moisture, material degradation and mold. Expanses of exterior metal cladding require an appearance of flatness that is not demanded of masonry or other building materials. Panel flatness in the CENTRIA FormaBond XYX metal wall system panel is assured by the combination of composite construction, and the addition of panel stiffeners bonded to the back of the panel when required. CENTRIA FormaBond panels are available in Kynar 500 or Hylar 5000 polyvinylidene fluoride (PVDF) finishes, including micas and metallics. PVDF coatings are a significant asset to the building owner. Highly UV resistant and durable in the face chemical and air borne pollution, salt spray and wind-driven sand, PVDF coatings are the Gold Standard of the industry. CENTRIA FormaBond wall systems are available in 60 standard colors and a wide selection of custom colors. Consult your local CENTRIA architectural representative for design assistance. Contact CENTRIA, Pittsburgh, PA, (800) , info@centria.com, for a list of offices. CENTRIA is a world leader in the manufacture of metal building products and systems for nonresidential walls and roofs. CENTRIA is also a world-class coil coater, coating a wide range of products for customers in numerous industries. CENTRIA products appear in the following MasterFormat sections: Section Metal Roof Panels (SRS3) Section Insulated Core Metal Roof Panels (Versapanel) Section Metal Wall Panels (Cascade Metal Panel System, Intercept V-trac, Intercept Entyre, Paradigm EXP, Concept Series, IW Series, Exposed Fastener Panels) Section Insulated-Core Metal Wall Panels (Formawall Dimension Series, Formawall Graphix Series, Versawall, Versapanel, Foamwall, VersaShield MW) Section Insulated Composite Backup Panel (MetalWrap) Section Composite Wall Panels (FormaBond) Specifier: This document is organized according to CSI MasterFormat TM. Edit section number and title as appropriate to the Project. Bold items require specifier selection. Convert bold to plain text and delete notes before publishing. FormaBond is a registered trademark of CENTRIA, Inc. Kynar 500 is a registered trademark of Arkema, Inc. Hylar 5000 is a registered trademark of Solvay S.A. MasterFormat TM is a trademark of the Construction Specifications Institute. This document is Copyright 2014 CENTRIA All rights reserved. Page 1 of 12

2 SECTION COMPOSITE WALL PANELS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below. Specifier: Retain one or more of three wall assembly descriptions below that correspond to Project Requirements; edit as required. Paragraph below describes installation of metal wall panels over CENTRIA MetalWrap backup system. 1. Metal Wall Panels over Insulated-Composite Backup Panel Wall System: Aluminum-faced composite panels applied as the exterior rainscreen cladding component of a metal wall panel system that includes insulated composite metal wall backup panels specified in Division 07 Section "Insulated-Composite Backup Panel System." Metal wall backup panels provide thermal, air, water, and water vapor control. Metal wall panel installation specified in this Section includes secondary metal subgirt framing for panel attachment. 2. Metal Wall Panels over Multi-Component Framed Wall System: Aluminum-faced composite panels applied as exterior rainscreen cladding over wall framing specified in Division 05 Section "Cold-Formed Metal Framing" with exterior sheathing specified in Division 06 Section "Sheathing", an applied membrane that provides air, moisture, and water vapor control specified in Division 07 Section "Air Barriers", and insulation within the framing specified in Division 07 Section "Thermal Insulation." Metal wall panel installation specified in this Section includes [secondary metal subgirt framing and] mounting clips for panel attachment. Specifier: Retain subparagraph below. Product is not by CENTRIA. a. Air, moisture, and water vapor control membrane is provided under Division 07 Section "Air Barriers." 3. Metal Wall Panels over Outside-Insulated Framed Wall System: Aluminum-faced composite panels applied as exterior rainscreen cladding over wall framing specified in Division 05 Section "Cold-Formed Metal Framing" with exterior sheathing specified in Division 06 Section "Sheathing", an applied membrane that provides air, moisture, and water vapor control specified in Division 07 Section "Air Barriers", and insulation [within the framing and] applied outboard of the sheathing specified in Division 07 Section "Thermal Insulation." Metal wall panel installation specified in this Section includes [secondary metal subgirt framing for panel attachment and] mounting clips for panel attachment. Specifier: Retain subparagraph below. Product is not by CENTRIA. a. Air, moisture, and water vapor control membrane is provided under Division 07 Section "Air Barriers." Page 2 of 12

3 1.2 RELATED REQUIREMENTS Specifier: Edit list below to correspond to Project. A. Division 01 Section "Sustainable Design Requirements" for related LEED general requirements. B. Division 07 Section "Air Barriers" for transition and flashing components of building air/moisture barrier. C. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal copings, flashings, reglets and roof drainage items. D. Division 07 Section "Joint Sealants" for field-applied joint sealants. 1.3 REFERENCE STANDARDS A. American Architectural Manufacturer's Association (AAMA): 1. AAMA Test Methods for Exterior Walls. 2. AAMA Voluntary Test Method and Specifications for Pressure Equalized Rain Screen Wall Cladding Systems 3. AAMA Voluntary Test and Classification Method for Drained and Back Ventilated Rain Screen Wall Cladding Systems. 4. AAMA Voluntary Specification High Performance Organic Coatings on Coil Coated Architectural Aluminum. B. American Society of Civil Engineers (ASCE): 1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures. C. ASTM International (ASTM): 1. ASTM A 653/A 653M - Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc- Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process. 2. ASTM B Specification for Aluminum and Aluminum Alloy Sheet and Plate. 3. ASTM B Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes. 4. ASTM C Specification for Nonstructural Steel Framing Members. 5. ASTM E 84 - Test Methods for Surface Burning Characteristics of Building Materials. 6. ASTM E Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors under Specified Pressure Differences across the Specimen. D International Building Code (IBC) 1.4 PERFORMANCE REQUIREMENTS A. General: Provide composite wall panel system meeting performance requirements as determined by application of specified tests by a qualified testing agency on manufacturer's standard assemblies. B. Structural Performance: Design composite wall panel system fabricated to withstand effects of indicated loads and stresses within limits and under conditions indicated below. Page 3 of 12

4 Specifier: Consult structural engineer and edit below as required by local codes. Insert structural data below if not indicated on drawings. 1. Wind Loads: Determine loads based on uniform pressure, building category, exposure category, and basic wind speed indicated on drawings. 2. Limits of Deflection: Composite wall panel system shall withstand design wind pressure with the following allowable deflection: a. Maximum allowable deflection limited to L/175 deflection of panel head and sill normal to plane of wall. b. Maximum allowable deflection of panel stiffeners and aluminum panel material combined limited to L/ Seismic Performance: Comply with ASCE 7 Section 9, "Earthquake Loads." C. System Performance: A third party test report utilizing the standard ASTM E 283, E 331 and AAMA 501 procedures following the test protocol described in AAMA must be submitted prior to bid. Test panel must include a horizontal joint, with an imperfect air barrier. D. Drained and Back Ventilated Rain Screen Performance: Per AAMA : 1. Water penetration through panel system: W1 classification. 2. Ventilation: V4 classification. Specifier: When specifying drained and back ventilated rain screen performance, retain one of two paragraphs below. Retain first paragraph if utilizing CENTRIA MetalWrap panel as the substrate for the FormaBond installation and the wall air/moisture barrier. Retain second paragraph if specifying air/moisture barrier in another section. 3. Air/Moisture Barrier: Refer to Division 07 Section "Insulated-Composite Backup Panel System." 4. Air/Moisture Barrier: Refer to Division 07 Section "Air Barriers." E. Thermal Movements: Allow for thermal movements from variations in both ambient and internal temperatures. Accommodate movement of support structure caused by thermal expansion and contraction. Specifier: Retain paragraph below if foam plastic insulation is included within the wall system. F. Wall systems that incorporate foam plastic insulation must comply with section 1407 of the 2012 International building code (IBC). 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: Approved manufacturer listed in this Section with minimum 10 years experience in manufacture of similar products in successful use in similar applications. 1. Approval of Comparable Products: Submit the following in accordance with project substitution requirements, within time allowed for substitution review: Page 4 of 12

5 a. Product data, including certified independent test data indicating compliance with requirements. b. Samples of each component. c. Sample submittal from similar project. d. Project references: Minimum of 5 installations not less than 5 years old, with Owner and Architect contact information. e. Sample warranty. 2. Substitutions following award of contract are not allowed except as stipulated in Division 01 General Requirements. 3. Approved manufacturers must meet separate requirements of Submittals Article. B. Wall Systems Installer Qualifications: Experienced Installer with minimum of 5 years experience with successfully completed projects of a similar nature and scope. C. Fire Performance Characteristics: Provide metal composite wall systems with the following firetest characteristics determined by indicated test standard as applied by UL or other testing and inspection agency acceptable to authorities having jurisdiction. 1. Surface-Burning Characteristics: Provide metal composite wall system panels with the following characteristics when tested per ASTM E a. Flame spread index: 25 or less. b. Smoke developed index: 450 or less. Specifier: Retain paragraph below if scope of composite wall panel installation warrants a mockup. Edit requirements to suit Project. Consider either a free-standing mockup or a mockup consisting of a portion of the final building cladding to establish standards of appearance and workmanship. Show extent of mockup on Drawings. Consult Project waterproofing or building envelope consultant, if any. D. Mockups: Build mockup in size and location indicated. Show details of composite wall panel system. Demonstrate methods and details of installation. Show details of gasketed return vertical joints, penetrations, doors, windows, louvers, pipe openings, inside and outside corners, top and bottom of wall, horizontal and vertical joints. 1. Approval of mockup does not relieve Contractor of responsibility to comply with all requirements of contract documents. 2. Approved mockup may become part of installation if approved by Architect. 1.6 ADMINISTRATIVE REQUIREMENTS A. Preinstallation Meeting: Conduct preinstallation meeting at site attended by Owner, Architect, manufacturer's technical representative, and other trade contractors. 1. Coordinate building framing in relation to composite wall panel system. 2. Coordinate installation of building air and water barrier behind composite wall panel system. 3. Coordinate windows, doors, louvers, and other openings and penetrations of composite wall panel system. Page 5 of 12

6 1.7 ACTION SUBMITTALS A. Product Data: Manufacturer s data sheets for specified products. B. Shop Drawings: Provide shop drawings prepared by manufacturer or manufacturer's authorized dealer. Include full elevations showing openings and penetrations. Include details of each condition of installation and attachment. Provide details at a minimum scale 1-1/2-inch per foot of all required trim and extrusions needed for a complete installation 1. Include data indicating compliance with performance requirements. 2. Indicate points of supporting structure that must coordinate with composite wall panel system installation. Specifier: Retain and edit below to comply with Project requirements for LEED 2009 or other sustainable design requirements. C. LEED Submittals: 1. Credit MR 4: Product data indicating the following: a. Percentages by weight of post-consumer and pre-consumer recycled content. b. Total weight of products provided. D. Samples for Initial Selection: For each product specified including sealants and gaskets. Provide representative color charts of manufacturer's full range of colors. E. Samples for Verification: Provide 24-inch (600 mm) section of wall panel showing finishes, horizontal joinery, vertical joint return, injected core material, panel stiffener and anchoring details. Provide 12-inch (300 mm) long pieces of each extruded aluminum trim and gaskets. 1.8 INFORMATIONAL SUBMITTALS A. Product Test Reports: Indicating compliance of products with requirements, from a qualified independent testing agency. Specifier: Retain paragraphs below when Project requirements include compliance with Federal Buy American provisions. CENTRIA FormaBond complies with requirement. B. Buy American Act Certification: Submit documentation certifying that products comply with provisions of the Buy American Act 41 U.S.C 10a 10d. C. Qualification Information: For Installer and Installer's field supervisor. D. Manufacturer's warranty: Submit sample warranty. 1.9 CLOSEOUT SUBMITTALS A. Maintenance data DELIVERY, STORAGE, AND HANDLING A. Protect products of composite wall panel system during shipping, handling, and storage to prevent staining, denting, deterioration of components or other damage. Page 6 of 12

7 1. Deliver, unload, store, and erect composite wall panel system and accessory items without misshaping panels or exposing panels to surface damage from weather or construction operations WARRANTY Specifier: Warranty terms below are available from CENTRIA. Verify that other allowable manufacturers furnish warranty meeting requirements. A. Special Manufacturer s Warranty: On manufacturer s standard form, in which manufacturer agrees to repair or replace metal wall panel assemblies that fail in materials and workmanship within [two] years from date of Substantial Completion. Specifier: Consult CENTRIA representative to verify available finish warranty. B. Special Panel Finish Warranty: On manufacturer s standard form, in which manufacturer agrees to repair or replace wall panels that evidence deterioration of finish within [20] years from date of Substantial Completion. PART 2 - PRODUCTS 2.1 SYSTEM DESCRIPTION A. Composite Metal Panel Wall System: Drained and back-ventilated rainscreen design consisting of dry seal joinery designed to minimize water penetration and induce air circulation in the space behind the panel system. Moisture weeping trim at panel base details allows water to drain out of the system. 2.2 MANUFACTURERS A. Basis of Design: CENTRIA, FormaBond Composite Wall Panel System. Provide basis of design product[, or comparable product approved by Architect prior to bid]. 1. CENTRIA Architectural Systems; Moon Township, PA Tel: (800) Tel: (412) Fax: (412) info@centria.com. Web: PANEL MATERIALS A. Aluminum Sheet: Smooth surface coil-coated sheet, ASTM B Thickness: [0.020"(0.51mm), 3105-H14 alloy] [0.032"(0.81mm) 5052-H32 alloy] B. Aluminum Extrusions: ASTM B 221, 6063-T5 Aluminum. C. Panel Core: Thermo-set, high density polyurethane, fire-retardant per ASTM E 84, with flamespread index of 25 or less and smoke-developed index of 450 or less. 2.4 COMPOSITE METAL PANELS Specifier: CENTRIA FormaBond panels are available in widths up to 58 (1473mm) inches and custom lengths up to 180 inches. Page 7 of 12

8 A. Composite Metal Panels: Factory-formed, aluminum-faced composite panels fabricated from two sheets of thick aluminum facing sheets with metal facings bonded to reaction injected thermoset,high density polyurethane core, and rout and return joinery. 1. Thickness: 8 mm. nominal. 2. Panel Flatness: Maximum allowable distortion: 1/32 inch in 24 inches (0.794 mm in 600 mm) in any direction. Panel Core: Thermo-set, high density polyurethane 3. Stiffeners: Manufacturer's standard stiffener as required to meet performance requirements. B. Face Sheet Surface: Smooth. Specifier: Select aluminum face sheet finish system from options below. AAMA 620 is aluminum sheet finish standard. C. Exposed Coil-Coated Finish: D. Face Sheet Coil-Coated Finish: 1. Fluoropolymer Two-Coat System: 0.2 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat, AAMA 620. a. Basis of Design: CENTRIA Fluorofinish. 2. Fluoropolymer Two-Coat Mica System: 0.2 mil primer with 0.8 mil 70 percent PVDF fluoropolymer color coat providing a pearlescent appearance, AAMA 620. a. Basis of Design: CENTRIA Sundance Mica. 3. Fluoropolymer Three-Coat Metallic System: 0.2 mil primer with 0.8-mil 70 percent PVDF fluoropolymer color coat containing metal flakes, and a 0.5 mil 70 percent PVDF fluoropolymer clear coat, AAMA 620. a. Basis of Design: CENTRIA Sundance AM. 4. Fluoropolymer Three Coat System: 0.2 mil primer with a 0.5 mil polyester base coat and a 0.8 mil nominal PVDF fluoropolymer top coat providing an iridescent finish. a. Basis of Design: CENTRIA KolorShift. Specifier: Allusion print coat limits the maximum module from 60" to 52". 5. Fluoropolymer Three Coat System: 0.65 mil color base coat and Primer with a 0.05 mil PVDF ink coat and a 0.45 nominal PVDF fluoropolymer clear coat. a. Basis of Design: CENTRIA Allusion. Specifier: Please list color(s) that have been selected below based on color chips that have been supplied. This ensures the highest quality finish and reduces confusion and project delays. 6. Color: [As selected by Architect from manufacturer's standard colors] [Match Architect's custom color]. Page 8 of 12

9 E. Unexposed Finish: Manufacturer's standard primer. F. Exposed Trim and Fastener Finish: Match panel finish. 2.5 COMPOSITE WALL PANEL ACCESSORIES A. Provide manufacturer's factory-formed clips, shims, flashings, sealants, and tapes for a complete installation. B. Extruded Trim: Aluminum, minimum thickness inch (1.59 mm) for trim and 0.90 inch (2.38 mm) for structural units. Include manufacturer-provided extruded trim for the following locations and as indicated on Drawings: 1. Base trim. 2. Coping. 3. Panel installation perimeter. 4. Opening perimeters. Specifier: Retain one of two paragraphs below when optional splines or gaskets are required for project. C. Splines: Match panel material and finish. D. Gaskets: Panel manufacturer's EPDM or neoprene, fire-retardant-treated. E. Sealants: Type recommended by composite wall panel system manufacturer for application, meeting requirements of Division 07 Section "Joint Sealants." F. Flashing Tape: 4 inch (102 mm) wide self-adhering butyl flashing tape. 2.6 SECONDARY METAL FRAMING Specifier: Retain and edit this article if miscellaneous framing will be required under work of this Section. A. Miscellaneous Framing Components, General: Cold-formed metallic-coated steel sheet, ASTM C 645, Grade 50, with ASTM A 653/A 653M, G90 (Z180) hot-dip galvanized zinc coating. 1. Hat Channels: 0.053"minimum/16 ga. (1.35 mm) minimum. 2. Sill Channels: 0.053" minimum/16 ga. (1.35 mm) minimum. 2.7 FABRICATION A. General: Fabricate composite wall panels and accessories at factory identical to tested units using manufacturer's standard procedures and processes necessary to meet performance requirements. 1. Provide components of composite wall panel system that are products of one manufacturer, including composite panels, gaskets, head and sill trim, bottom weep, base extrusion, and metal copings. B. Composite Panels: Fabricate composite wall panels with extruded aluminum stiffeners requiring no further fabrication or modification in field. 1. Horizontal Joints: Dry seal, drained and back ventilated. Page 9 of 12

10 2. Vertical Joints: Pre-formed returns with [metal spline] [gasket] and aluminum extrusion receptors and extruded drain channels. 3. Horizontal Reveals: [ 0.50" (12.7 mm)] [ 1.0" (25.4 mm)] [ 1.5" (38.1 mm)] [ 2.0 inch (50.8 mm)] [ 2.5" (63.5 mm)] [ 3.0" (76.2 mm)] [ 3.5" (88.9 mm)] [ 4" (101.6 mm)] [ 4.5" (114.3 mm)] [ 5.0" (127 mm)] [ 5.5" (139.7 mm)] [ 6.0" (152.4 mm)] 4. Vertical Reveals: [ 0.50" (12.7 mm)] [ 5/8" (15.88 mm)] [ 1.0" (25.4 mm)] [ 1.5" (38.1 mm)] [ 2.0 inch (50.8 mm)] [ 2.5" (63.5 mm)] [ 3.0" (76.2 mm)] [ 3.5" (88.9 mm)] [ 4" (101.6 mm)] [ 4.5" (114.3 mm)] [ 5.0" (127 mm)] [ 5.5" (139.7 mm)] [ 6.0" (152.4 mm)] 5. Formed Panel Thickness: 2-11/16" (68.3 mm). PART 3 - EXECUTION 3.1 EXAMINATION A. Examine composite wall panel system substrate with Installer present. Inspect for erection tolerances and other conditions that would adversely affect installation of composite wall panels. B. Wall Substrate: Confirm that wall substrate is within tolerances acceptable to metal wall panel system manufacturer. 1. Maximum deviations acceptable: a. 1/4-inch in 20 feet (6.4 mm in 6 m) vertically or horizontally from face plane of framing. b. 1/2-inch (12.7 mm) across building elevation. c. 1/8-inch in 5 feet (3.2 mm in 1.5 m). C. Framing: Inspect framing that will support composite wall panel system to determine if support components are installed as indicated on approved shop drawings. Confirm presence of acceptable framing members to match installation requirements of composite wall panel system. 1. Minimum:. 053 inch/16 ga (1.35 mm) 2. Maximum: 24 inch (610 mm) D. Verify that windows, doors, louvers, and other penetrations match layout on shop drawings. E. Advise G.C., in writing, of out-of-tolerance work and other deficient conditions prior to proceeding with metal wall panel system installation. F. Correct out of tolerance work and other deficient conditions prior to proceeding. 3.2 COMPOSITE WALL PANEL SYSTEM INSTALLATION A. General: Install composite wall panel system in accordance with approved shop drawings and manufacturer's recommendations. B. Installation: Attach panels to metal framing using recommended clips, screws, fasteners, sealants, and adhesives indicated on approved shop drawings. Page 10 of 12

11 1. Horizontal Joinery: Working from base of installation to top, connect upper panel to lower panel at dry seal joinery utilizing field-applied attachment clip. 2. Vertical Joinery: Provide reveal between vertical ends of panels as shown on shop drawings using hardware furnished by manufacturer. Specifier: Retain subparagraph below when gaskets or splines are required for project. a. Install gaskets where indicated. b. Install splines where indicated. 3. Galvanic Action: Where elements of metal composite wall system will come into contact with dissimilar materials, treat faces and edges in contact with dissimilar materials as recommended by manufacturer. C. Rainscreen Installation: Proceed with installation of manufacturer's dry seal horizontal joinery. Keep open spaces in horizontal joinery intended to ventilate cavity behind system. 3.3 FIELD QUALITY CONTROL A. Manufacturer's Field Service: Engage a service representative authorized by metal wall panel manufacturer to inspect completed installation. Submit written report. Correct deficiencies noted in report. 3.4 CLEANING AND PROTECTION A. Remove temporary protective films within 2 weeks of erection. Clean finished surfaces as recommended by metal wall panel manufacturer. Clear weep holes and drainage channels of obstructions, dirt, and sealant. Maintain in a clean condition during construction. B. Replace damaged panels and accessories that cannot be repaired by field repair. END OF SECTION Page 11 of 12

12 Additional Specifier's' Notes for CENTRIA FormaBond Composite Wall Panels Substitution Reviews: When reviewing substitution requests for other products for compliance with this specification, CENTRIA recommends particular attention to the following issues: Rainscreen system engineering: Require submittal of sample shop drawings from a similar project to determine whether the quality of the total proposed package meets CENTRIA's standards. Do edge conditions and opening conditions include extruded trim rather than formed metal, metal spline or dry gasketing instead of liquid sealants, secondary framing meeting metal thickness and corrosion resistance requirements, and proper mounting hardware? Quality of high performance finishes: Require submittal of large scale coating samples on the specified substrate to enable comparison of finish quality. Are desired colors and visual effects comparable to CENTRIA's own coating line finishes? Have previous projects with similar coating proven durable? Examination of similar installations: Panel flatness and substrate flatness are important components of overall installation quality. Does the manufacturer/installer meet the CENTRIA's tolerances specified in this Section? Coordination with Drawings: CENTRIA recommends you coordinate the following: Show details of integrated windows, wall louvers, and sunscreen units specified in other Sections but provided by this Installer and shown on coordinated shop drawings. Show interfaces between panels, panel trim, and integrated units. Show details that allow for moisture penetration into and weeping from the drained and back ventilated cavity behind the CENTRIA rainscreen wall panel system. Show unobstructed path for moisture movement to the exterior, along with moisture barrier and flexible flashings specified in other Sections. Detail edge conditions with extruded trims that protect the panel edges, especially at panel bottom. Show soffits, sills, expansion joints and other components either specified in this Section or referenced from this Section to Related Sections. Page 12 of 12

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.

More information

CENTRIA FORMABOND II Metal Composite Wall System

CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FormaBond II is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer

More information

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre is a unique modular metal wall system designed, available from a reliable national manufacturer and supported

More information

CENTRIA EcoScreen Perforated Screen Wall Panels

CENTRIA EcoScreen Perforated Screen Wall Panels CENTRIA EcoScreen Perforated Screen Wall Panels CENTRIA EcoScreen Perforated Screen Wall Panels offer a variety of aesthetic solutions to equipment and other screening design requirements. EcoScreen Panels

More information

CENTRIA Concept Series Metal Wall Panels ZINC

CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles and five

More information

CENTRIA Exposed Fastener Series Metal Wall Panels

CENTRIA Exposed Fastener Series Metal Wall Panels CENTRIA Exposed Fastener Series Metal Wall Panels CENTRIA Exposed Fastener Series Metal Wall Panels are a versatile design choice for both new and retrofit projects. Exposed Fastener Metal Wall Panels

More information

CENTRIA Concept Series TM Metal Wall Panels

CENTRIA Concept Series TM Metal Wall Panels CENTRIA Concept Series TM Metal Wall Panels CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles, metal substrates,

More information

CENTRIA MetalWrap Insulated-Composite Backup Panel System

CENTRIA MetalWrap Insulated-Composite Backup Panel System CENTRIA MetalWrap Insulated-Composite Backup Panel System CENTRIA MetalWrap Insulated Composite Backup Panel System is designed to be used with CENTRIA metal wall panel cladding to create a complete rainscreen

More information

SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) SECTION 07 42 13.01 METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 620 AAMA 621 Voluntary Specification for High Performance Organic Coatings

More information

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) SECTION 07 42 13.03 METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 620 AAMA 621 Voluntary Specification for High Performance Organic Coatings

More information

SECTION STAINLESS STEEL WALL PANELS

SECTION STAINLESS STEEL WALL PANELS SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.

More information

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002 SECTION 07 42 13 ALUMINUM PLATE PANEL SYSTEM ALPLY Insulated Panels Alply TECH WALL Aluminum Plate System 2002 PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Preformed Aluminum Plate System for Screen wall

More information

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>. SECTION 074213.23 METAL COMPOSITE MATERIAL WALL PANELS PART 1 GENERAL 1.1 SUMMARY A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary supports and anchors to structure,

More information

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>. SECTION 074213.23 METAL COMPOSITE MATERIAL WALL PANELS PART 1 GENERAL 1.1 SUMMARY A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary supports and anchors to structure,

More information

CENTRIA Formawall Graphix Series Insulated Core Metal Wall Panel System

CENTRIA Formawall Graphix Series Insulated Core Metal Wall Panel System CENTRIA Formawall Graphix Series Insulated Core Metal Wall Panel System CENTRIA Formawall pressure-equalized insulated core metal wall panel system is designed as a complete wall solution. Formawall provides

More information

CENTRIA Versawall Factory Foamed Metal Wall Panel System

CENTRIA Versawall Factory Foamed Metal Wall Panel System CENTRIA Versawall Factory Foamed Metal Wall Panel System Often recommended for industrial applications, the CENTRIA Versawall Factory Foamed Panel System is also often used for low- and mid-rise buildings

More information

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System CENTRIA Formawall pressure-equalized insulated core metal wall panel system is designed as a complete wall solution. Formawall

More information

CENTRIA MetalWrap Insulated-Composite Backup Panel System with Integrated Windows and Louvers

CENTRIA MetalWrap Insulated-Composite Backup Panel System with Integrated Windows and Louvers CENTRIA MetalWrap Insulated-Composite Backup Panel System with Integrated Windows and Louvers CENTRIA MetalWrap Insulated Composite Backup Panel System is designed to be used with CENTRIA Formavue FV-600

More information

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System CENTRIA Formawall pressure-equalized insulated core metal wall panel system is designed as a complete wall solution. Formawall

More information

SECTION INSULATED CORE METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

SECTION INSULATED CORE METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) SECTION 07 42 16.05 INSULATED CORE METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 501.2 AAMA 621 AAMA 2605 (2003) Quality Assurance and Diagnostic

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

Guide Specifications ADP Series SECTION SHEET METAL ROOFING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]

More information

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants. Section 07 42 13 Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants. 1.2 RELATED SECTIONS A. Section 06112 - Framing

More information

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels SPECIFICATIONS FOR (1/13 Edition) CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System Section 074243 Aluminum Composite Panels (Based upon CEI Composite Materials R4000

More information

SECTION EXTERIOR GRILLS AND SCREENS

SECTION EXTERIOR GRILLS AND SCREENS SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM SECTION 07400 TERRA COTTA CLAY TILE RAINSCREEN SYSTEM PART 1 GENERAL 1.01 WORK INCLUDED A. The terra cotta clay tile elements and aluminum support system shall be manufactured by NBK Keramik GmbH as represented

More information

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek) SECTION 074251 (Porcelanosa Venis Urbatek) PART 1 - GENERAL 1.1 GENERAL PROVISIONS A. Attention is directed to the CONTRACT AND GENERAL CONDITIONS and all Sections within DIVISION 01 - GENERAL REQUIREMENTS

More information

SECTION METAL WALL PANEL SYSTEM

SECTION METAL WALL PANEL SYSTEM CSI Format for Metal Wall Panel System Specification SECTION 07410 METAL WALL PANEL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior Metal Plate Wall Panels B. Substructure and Framing C. Structural

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying metal wall panels

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 074243- METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 074243 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication

More information

CENTRIA Profile Series Exposed Fastener Metal Roof Panels

CENTRIA Profile Series Exposed Fastener Metal Roof Panels CENTRIA Profile Series Exposed Fastener Metal Roof Panels CENTRIA Profile Series Exposed Fastener Metal Roof Panels are a versatile design choice for both new and retrofit projects. Panels are manufactured

More information

SECTION METAL ROOF PANELS. A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories.

SECTION METAL ROOF PANELS. A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories. SECTION 07 41 13 - PART 1 - GENERAL 1.1 SECTION INCLUDES A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories. 1.2 RELATED REQUIREMENTS Specifier: If

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

SECTION EXTERIOR SUN SHADES

SECTION EXTERIOR SUN SHADES SECTION 10 71 13 EXTERIOR SUN SHADES USE THIS SECTION WHEN SPECIFYING C.R. LAURENCE 7700 SERIES ALUMINUM SUN SHADE SYSTEMS. THE CRL 7700 SERIES SUN SHADE SYSTEM IS A FIXED BAR GRILLE STYLE WITH A TAPERED

More information

SECTION METAL ROOF PANEL, STANDING SEAM - SRS3

SECTION METAL ROOF PANEL, STANDING SEAM - SRS3 SECTION 07 41 13.03 METAL ROOF PANEL, STANDING SEAM - SRS3 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred

More information

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE PART 1 - GENERAL 1.1 SUMMARY SECTION 07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit

More information

Project Name Project # Project Information

Project Name Project # Project Information SECTION 074229.00 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS This suggested guide specification has been developed using

More information

Guideline Specifications

Guideline Specifications Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included

More information

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1 Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION SECTION 074213.23 4mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and General Provisions of Contract, including General and Supplementary

More information

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.*** ***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Clear copper and preweathered copper

More information

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION SECTION 074213.23 4mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and General Provisions of Contract, including General and Supplementary

More information

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS SECTION 07 42 13.26 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Zinc alloy metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

[Project Name] Section [ ]

[Project Name] Section [ ] Page 1 PART 1 - GENERAL 1.1 SECTION INCLUDES 1.1.1 Design, labor, products, equipment and services necessary for interior/exterior Aluminum Facade System (AFS) work, in accordance with the Contract Documents.

More information

Page 1 of 5

Page 1 of 5 SPECIFICATIONS COMPOSITE MATERIAL PANEL SYSTEM ESTOLGA 1000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary

More information

Skyline Sheet Metal, Inc.: SSMXRS Pressure Equalized Rainscreen Wall Cladding System

Skyline Sheet Metal, Inc.: SSMXRS Pressure Equalized Rainscreen Wall Cladding System Skyline Sheet Metal, Inc.: SSMXRS Pressure Equalized Rainscreen Wall Cladding System SECTION 07420 COMPOSITE ALUMINUM PANELS PART 1 GENERAL 1.01 SUMMARY A. Provide Composite Aluminum Extrusion Reveal Molding

More information

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS SECTION 074233 EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS PART 1 - GENERAL 1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION METAL WALL PANELS

SECTION METAL WALL PANELS Unience USA, Inc. 2115 Linwood Avenue, Suite 500 Fort Lee, NJ 07024 Phone: 201-676-2467 Fax: 201-944-3660 Email: alfrex@alfrexusa.com Web: www.alfrexusa.com SECTION 07 42 13 METAL WALL PANELS PART 1 GENERAL

More information

LOG COLLEGE MIDDLE SCHOOL

LOG COLLEGE MIDDLE SCHOOL PART 1-GENERAL 1.1 SUMMARY A. This section includes the following: 1. Curb-mounted plastic glazed skylights. B. Refer to roofing system sections for roofing accessories to be built into the roofing system

More information

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SECTION 07 42 43 All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SPEC NOTE: Optional text is indicated by square brackets []. Delete unwanted items and

More information

by Rollfab Metal Products

by Rollfab Metal Products by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and

More information

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS This suggested guide

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

EC-250 AAMA Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System

EC-250 AAMA Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System EC-250 AAMA 508-07 Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System SECTION 074213.16 ALUMINUM PLATE PANELS PART 1 GENERAL 1.1 SECTION INCLUDES A. ALUMINUM PLATE PANELS USED AS EXTERIOR

More information

North Hanover Township School District North Hanover Township, New Jersey

North Hanover Township School District North Hanover Township, New Jersey SECTION 084413 - GLAZED ALUMINUM CURTAIN WALLS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows. SECTION 085113 - ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fixed and operable aluminum-framed windows. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide aluminum windows capable

More information

COMPOSITESIDING

COMPOSITESIDING SECTION 074643 COMPOSITE SIDING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT SECTION 085200 - WOOD WINDOWS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

CS-100 Guide Specifications

CS-100 Guide Specifications MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

SECTION ALUMINUM COMPOSITE WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION ALUMINUM COMPOSITE WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.*** ***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Aluminum faced, thermoplastic core,

More information

Omniplate Barrier Wall System

Omniplate Barrier Wall System is an economical barrier wall system with visible caulk joints at all horizontal and vertical panel joints. As a barrier wall, serves as the primary weather barrier for the building envelope. It can be

More information

COLLEGE OF STATEN ISLAND

COLLEGE OF STATEN ISLAND SECTION 07415 ALUMINUM PLATE CEILING PANELS PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. The extent of panel system work is indicated on the drawings and in these specifications. The following specification

More information

SECTION AWNINGS

SECTION AWNINGS SECTION 10 73 13 AWNINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Fixed metal awnings. 1.2 DEFINITIONS A. Awning: An architectural projection that provides weather protection,

More information

ALUMABOARD SECTION ALUMINUM SIDING AND SOFFITS. A. Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

ALUMABOARD SECTION ALUMINUM SIDING AND SOFFITS. A. Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits. ALUMABOARD SECTION 07 46 00 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and accessories.

More information

A. Meet at Project site <insert number> days before starting installation.

A. Meet at Project site <insert number> days before starting installation. SECTION 074643 - COMPOSITION SIDING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Engineered wood cladding. 2. Soffit panels. 3. Trim and fascia. 4. Sealant. 5. Weather barrier. 6. Flashing. 1.2

More information

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS SECTION 07 4213.29 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Textured, aluminum metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support

More information

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels. 1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation

More information

SECTION ROOFING AND SIDING PANELS

SECTION ROOFING AND SIDING PANELS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 40 00 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

Expansion Joint Covers (079513)

Expansion Joint Covers (079513) Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Metl-Span FW-120 Formed Metal Wall Panels

Metl-Span FW-120 Formed Metal Wall Panels FW-120 Formed Metal Wall Panels The FW-120 panel is a concealed fastener wall and liner panel that provides a flat appearance. FW- 120 is commonly used for architectural, commercial and industrial markets.

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08

More information

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS SECTION 074213.23 - WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Metl-Span ShadowRib Formed Metal Wall Panels

Metl-Span ShadowRib Formed Metal Wall Panels ShadowRib Formed Metal Wall Panels ShadowRib is a 3-inch- deep panel that combines aesthetics, economy and function to bring definition to metal structures. ShadowRib is a proven performer and a versatile

More information

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS SECTION 08620 COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Expansion Joint Covers

Expansion Joint Covers Expansion Joint Covers 07 95 00 (079513) PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Supplementary Conditions and Division-1

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

METAL COMPOSITE MATERIAL WALL PANELS

METAL COMPOSITE MATERIAL WALL PANELS MasterSpec Full Length 1 of 10 SECTION 074213.23 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes metal composite material wall panels. 1.2 PREINSTALLATION MEETINGS

More information

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS PART 1 GENERAL SECTION 08 1116 ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS 1.01 SECTION INCLUDES A. Aluminum-framed storefront, with vision glass. B. Infill panels of glass. C. Aluminum doors

More information

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1 Fitness Facility Addition Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Extruded aluminum windows with fixed sash..2 Factory glazed..3 Perimeter sealant. 1.2 RELATED SECTIONS.1 Section 05500 - Metal Fabrications.2

More information