Environmental Products. Designed to Protect and Improve Our Environment. Delivering Reliability

Size: px
Start display at page:

Download "Environmental Products. Designed to Protect and Improve Our Environment. Delivering Reliability"

Transcription

1 Delivering Reliability A Designed to Protect and Improve Our Environment Environmental Products Sales & Service 888-9Oldcastle ( )

2 A Environmentally Responsible COVER & FRAME Oldcastle Precast to the Rescue All of our products are produced in a controlled environment helping us maintain the high standards implemented by Oldcastle Precast. Many of our products are specifically designed to protect and improve the environment. We re always looking for new ways to minimize waste, increase recycling, improve energy management and use eco-friendly materials. FINISH:Hot Dip Galvanized after Fabrication. FRAME:Can be Fabricated for Cast-In Applications. LOADING:Designed for H20 loading for Non Roadway Applications. DOORS: Offered in Single, Double, or Triple Configurations, open 180 Degrees. EMBEDDED LIFTERS MATERIAL:Carbon Steel LOADING:Offered in 2, 4, 8, & 20 Ton 1 Ton Universal Lifters also available. Material and Design Loads The structural notes below are for standard models. We can design vaults to meet other specifications. 1. Concrete 5000psi (35 28 days. 2. Rebar ASTM A 615 grade 60 rebar. 3. Mesh Welded Wire Fabric ASTM A185 grade Design Building Code Requirements for Reinforced Concrete (ACI ) including all referenced standards and specifications. AASHTO Standard Specifications for Highway Bridges - 16th edition. 5. Loads Dead Load: Concrete PCF Earth Cover PCF Lateral Earth Pressure on walls: Equivalent Fluid pressure above water table PSF per foot of depth. Equivalent Fluid pressure below water table PSF per foot of depth. Surcharge on walls + 2 feet of earth cover Live Load: AASHTO HS ,000 lbs. rear axle loading GRADE RINGS / RISERS FINISH:Concrete with various Coatings/Textures. Designed to bring Covers up to Grade. Can be Rectangular or Round. Suitable for Off-Street Traffic. INLET PIPE Supplied by others SLUDGE WEIR Weight Varies by size FACET M-PAC Coalescing Media Shown with (3) rows We can provide drawings and calculations stamped by a Professional Engineer.

3 Environmental Vaults Sales & Service SINGLE GREASE INTERCEPT Can be Fabricated in a variety of Sizes. MANHOLE COVER & FRAME MATERIAL:Cast or Ductile Iron. DESIGNS:Custom Lettering & Design available. LOADING:Built to an H20 rating up to 150 KIP. SIZES: 24, 30, 32, 36 Round OIL WEIR Weight Varies by Size OUTLET PIPE Supplied by Others Size Varies by vault type OUTLET WEIR Weight Varies by size

4 Oil/Water Separator Vault Oil & Water Separator Vaults We offer a wide range of oil & water separator vaults to meet the specific application needs of our customers. From smaller capacity 35 GPM (gallon per minute) vaults, to larger capacity 800 GPM vaults and everything in between.

5 Sales & Service Grease Interceptor Vault Single Grease Interceptor Vault We offer grease interceptors that can be desinged and configured to meet a wide range of commercial applications as well as soecific performance criteria. LID SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. DESIGNED FOR AASHTO HS-20 LOADING BASE SECTION SPECIAL ACCESSES, CASTOUTS, KNOCKOUTS, ETC. can be placed as specified. DESIGNED FOR AASHTO HS-20 LOADING DESIGNED ACCORDING TO ASTM C AND ASTM C858-83s. *Grease Interceptor vaults are available in a variety of standard and custom sizes to suit virtually any application.

6 Sand/Oil Interceptor Vault Sand & Oil interceptor Vault We offer a wide range of sand & oil interceptor vaults to meet the specific application needs of our customers. From smaller 320 gallon capacity vaults, to larger GPM capacity vaults and everything in between. LID SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. DESIGNED FOR AASHTO HS-20 LOADING Retaining Baffle for Sand Interceptor BASE SECTION SPECIAL ACCESSES, CASTOUTS, KNOCKOUTS, ETC. can be placed as specified. DESIGNED FOR AASHTO HS-20 LOADING DESIGNED ACCORDING TO ASTM C AND ASTM C858-83s. *Sand & Oil vaults are available in a variety of standard and custom sizes to suit virtually any application.

7 Sales & Service Interceptor Vaults Standard Sizes for Interceptor Vaults We offer a wide range of standard sized interceptor vaults to meet the specific application needs of our customers. From smaller capacity 320 Gallon vaults, to larger capacity 11,000 Gallon vaults and everything in between. Elevation Plan STANDARD INTERCEPTOR VAULTS Gallon Capacity MODEL A B C D E F WEIGHT SI ,535 LBS SI ,631 LBS SI ,031 LBS SI ,231 LBS SI ,431 LBS SI ,831 LBS SI ,031 LBS SI ,231 LBS SI ,529 LBS SI ,454 LBS SI ,521 LBS SI ,702 LBS SI ,964 LBS SI ,462 LBS SI ,883 LBS SI ,708 LBS SI ,451 LBS SI ,949 LBS SI ,692 LBS

8 Environmental Delivering Reliability A Oldcastle Precast Oldcastle Precast is the leading manufacturer of precast concrete, polymer concrete, and plastic products in the United States. With a nationwide network of facilities, our products are always close at hand. Our employees are committed to upholding core values of reliability, quality, and service in revolutionary ways. Our attention to detail exceeds the expectations of customers from some of the largest companies in the U.S., across a spectrum of industries. Sales & Service Oldcastle ( ) 2010 Oldcastle Precast, Inc. V1_121409

Inlets & Catch Basins

Inlets & Catch Basins A Delivering Reliability Inlets & Catch Basins Water-Conveyance & Drainage A Environmentally Responsible Oldcastle Precast to the Rescue All of our products are produced in a controlled environment helping

More information

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures A Delivering Reliability Electrical Vaults Power & Energy-Underground Structures A The Benefits of Precast Vaults Electrical vaults house power cables and transformers, and are a preferred alternative

More information

16. Design of Pipeline Structures.

16. Design of Pipeline Structures. 16. Design of Pipeline Structures. a. General. 1) The following guidelines are for the design of structures for water and sewer pipelines including structural concrete and miscellaneous metals design.

More information

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid Section I: Castings and Aluminum Covers I 1 I 2 I 3 I 4 Valve Boxes Service Clean-out Box and Lid Manhole Casting/ Standard Ring and Cover Access Covers/ Aluminum 1 I 1 VALVE BOXES: Valve boxes shall meet

More information

401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply:

401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply: SECTION 400 SANITARY SEWER SYSTEM The design of sanitary sewers shall be in conformance with the applicable sections of the State of Washington, Department of Ecology manual, Criteria for Sewage Works

More information

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems SECTION 02607-1 1.0 GENERAL 1.1 SCOPE: A. This section covers the work necessary for the construction of sanitary and storm system manholes, catch basins, and miscellaneous concrete structures complete.

More information

400 Gal. Grease Interceptor

400 Gal. Grease Interceptor 400 Gal. Grease Interceptor PC-000-331 Secondary chamber volume equal to 1/2 total capacity. Verify compliance with local regulations. STM-C-478 specifications for water and wastewater structures. utyl

More information

TRENCH SYSTEM Pedestrian channels are rated for 200 lbs./ft 2 Pedestrian channels are rated for 200 lbs./ft 2 8012 (10X10) 12" 10" 10" 10" 8022 (20X20) 12" 20" 20" 20" 8026 (24X24) 12" 24" 24" 24"

More information

2.1.2 Minimum wall thickness shall be 90 mm Frames and covers shall be bitumen coated by dipping.

2.1.2 Minimum wall thickness shall be 90 mm Frames and covers shall be bitumen coated by dipping. 1.0 GENERAL 1.1 Scope 2.0 PRODUCTS 1.1.1 The work shall consist of the construction, renovation or the adjustment of manholes and/or catchbasins as detailed on the plans or where designated by the Engineer

More information

PERMANENT PAVEMENT REPAIR NO SCALE

PERMANENT PAVEMENT REPAIR NO SCALE SAWCUT EXISTING PAVEMENT 2" BITUMINOUS CONCRETE SURFACE COURSE, CLASS 2 (MIN) CLEAN EDGE PRIOR TO PAVING AND PAINT WITH LIQUID BITUMEN. INSTALL SEALANT OVER JOINT UPON COMPLETION 2" BITUMINOUS CONCRETE

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 03 45 00_PRECAST CONCRETE STRUCTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including

More information

ZG Scope. 2 Applicable Documents. 3 General. 4 Stock Item Numbers. Padvault Single-Phase Residential, 2.1 PacifiCorp Material Specifications

ZG Scope. 2 Applicable Documents. 3 General. 4 Stock Item Numbers. Padvault Single-Phase Residential, 2.1 PacifiCorp Material Specifications 1 Scope This specification outlines the minimum requirements for a 48 48 padvault for single-phase primary service. Single-phase transformers and sectionalizers (elbow switched cabinets) can be mounted

More information

Qualified Product Policy 15 Drainage Structure Miscellaneous Components Qualified Product List 14 [G] Heavy Duty Gray Cast Iron

Qualified Product Policy 15 Drainage Structure Miscellaneous Components Qualified Product List 14 [G] Heavy Duty Gray Cast Iron SCDOT Qualified Product Policy 15 1 SOUTH CAROLINA DEPARTMENT OF TRANSPORTATION Drainage Structure Miscellaneous Components (See also QPL14 for precast drainage structure components) This policy covers

More information

Storm Drainage

Storm Drainage University of New Hampshire University of New Hampshire Scholars' Repository Division 33 Utilities Chapter 5 Technical Construction and Renovation Standards 4-23-2015 334100 - Storm Drainage Sandra Hickey

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-33 16 13.16 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-13208 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

SECTION XXXX POLYMER CONCRETE PUMP STATIONS

SECTION XXXX POLYMER CONCRETE PUMP STATIONS SECTION XXXX POLYMER CONCRETE PUMP STATIONS PART 1 GENERAL 1.1 SUMMARY A. This specification shall govern for the furnishing of all work necessary for installation of polymer concrete pump stations to

More information

3/23/2016. Happy Pi Day! What We Will Discuss. Best Practices for Precast Concrete Tank Inspections

3/23/2016. Happy Pi Day! What We Will Discuss. Best Practices for Precast Concrete Tank Inspections Best Practices for Precast Concrete Tank Inspections 29 th Annual GSDI Spring Septic System Conference & Expo Monday March 14, 2016 Claude Goguen, PE, LEED AP, National Precast Concrete Association Happy

More information

CONCRETE TECHNOLOGY CORPORATION

CONCRETE TECHNOLOGY CORPORATION PRECAST, PRESTRESSED HOLLOW CORE SLABS DESIGN CRITERIA & SPAN-LOAD CHARTS FOR STORM WATER DETENTION VAULT LIDS (CHARTS REVISED /18/08) Introduction Design Criteria for Development of the Span-Load Charts

More information

AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS

AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS Works and Emergency Services CITY OF TORONTO WATER AND WASTEWATER SERVICES STANDARD CONSTRUCTION SPECIFICATIONS TS 408 November 2010 AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING

More information

SECTION PRECAST CONCRETE MANHOLES

SECTION PRECAST CONCRETE MANHOLES SECTION 02601 PRECAST CONCRETE MANHOLES PART 1 GENERAL 1.1 The work specified in this section shall include the furnishing, hauling, and placing of all precast manholes shown on the drawings and as specified

More information

TYPE "A" CATCH BASIN

TYPE A CATCH BASIN 27" 1.67' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3250-BV OR APPROVED EQUAL. "INFI SHIELD" SEAL OR APPROVED EQUAL RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE,

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Miscellaneous and Cast Iron Listings

Miscellaneous and Cast Iron Listings aeconcrete.com May 2017 Miscellaneous and Cast Iron Listings Drawing Number Item Description Product Size (Length X Width X Depth in mm) SVVZ-20-SUMP-C Drainage Sump w/ Cover 660 x 510 x 765 i.d. SVVZ-NC-SUMP-C

More information

WWR For Structural Applications A Discussion of Current Product Knowledge and Practices

WWR For Structural Applications A Discussion of Current Product Knowledge and Practices TF 208-R-08 WWR For Structural Applications A Discussion of Current Product Knowledge and Practices INTRODUCTION With its greater strength, generally higher ductility, and significantly lower placing and

More information

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems. The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains

More information

Current Standard Plates including Transmittal Letters are available on the web at:

Current Standard Plates including Transmittal Letters are available on the web at: MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (6-03) MANUAL: Standard

More information

Appendix J: Structural Engineering

Appendix J: Structural Engineering Bass Ponds, Marsh, and Wetland Habitat Rehabilitation and Enhancement Project Feasibility Report and Integrated Environmental Assessment Upper Mississippi River Restoration Program January, 2019 TABLE

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

OVERALL STRUCTURAL SYSTEM

OVERALL STRUCTURAL SYSTEM EXECUTIVE SUMMARY The at the Pittsburgh International Airport, PA, is a 275,000 square foot multi-use building located directly adjacent to the airport s landside terminal. The building consists of an

More information

Section 10 Design Criteria: Components

Section 10 Design Criteria: Components 1. Tanks and Vaults Section 10 Design Criteria: Components a. Watertightness i. Septic tanks, vaults, dosing tanks, other treatment components, risers and lids must not allow infiltration of ground water

More information

PIPE CULVERTS. Construct pipe culverts, beveled ends, pipe aprons, and associated appurtenances.

PIPE CULVERTS. Construct pipe culverts, beveled ends, pipe aprons, and associated appurtenances. PIPE CULVERTS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe Culverts B. Pipe Aprons and Beveled Ends C. Footings for Concrete Pipe Aprons D. Pipe Apron Guards 1.02 DESCRIPTION OF WORK Construct pipe culverts,

More information

PRECAST CONCRETE ON-SITE WASTEWATER TANKS

PRECAST CONCRETE ON-SITE WASTEWATER TANKS PRECAST CONCRETE ON-SITE WASTEWATER TANKS OUTLINE Purpose Precast Advantage Design Goals Applicable Standards Structural Design Materials Production Watertightness Installation NPCA Plant Certification

More information

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings 1993 Specifications CSJ 0144-01-060 SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings 1. General. (1) Scope. This Section includes the furnishing, installation, and subsequent

More information

SECTION GROUND WATER STORAGE TANKS

SECTION GROUND WATER STORAGE TANKS SECTION 33 16 13 GROUND WATER STORAGE TANKS PART 1: GENERAL 1.01 SCOPE A. Section includes requirements for designing, fabricating, and erecting a welded steel ground storage tank. 1.02 SYSTEM DESCRIPTION

More information

IAPMO Z yy. Rainwater Harvesting Tanks. 1 Scope. 2 Reference Publications

IAPMO Z yy. Rainwater Harvesting Tanks. 1 Scope. 2 Reference Publications Standards Action - February 10, 2017 - Page 29 of 40 pages IAPMO Z1002 20yy 1 Scope 1.1 This Standard covers rainwater harvesting tanks and specifies requirements for design, materials, manufacture, performance,

More information

POST FRAME BUILDING STANDARDS

POST FRAME BUILDING STANDARDS CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 POST FRAME BUILDING STANDARDS 201.3

More information

CHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION.

CHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION. Standard Drawings Index NOTE: The specifications for materials and workmanship shall conform to the latest edition or the "Standard Specifications for Public Works Construction" published by the North

More information

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS To prevent the contamination of the public water supplies from nearby sanitary sewers, the following State Water Resources Control Board Division

More information

Hydrodynamic Separation Product Calculator

Hydrodynamic Separation Product Calculator Hydrodynamic Separation Product Calculator Example Project BMP #1 CDS 2015-4 Project Information Project Name Example Project Option # A Country US State Kentucky City Covington Contact Information First

More information

Section G1. Design of Cast-In-Place Box Conduits

Section G1. Design of Cast-In-Place Box Conduits G1-1 Economy of Design 1. Height to Width Ratio Section G1 Design of Cast-In-Place Box Conduits Careful economic studies should be made to determine the greatest economy of the entire storm drain. As an

More information

VALLECITOS WATER DISTRICT SECTION PRECAST REINFORCED CONCRETE MANHOLES

VALLECITOS WATER DISTRICT SECTION PRECAST REINFORCED CONCRETE MANHOLES PART 1 GENERAL 1.1 DESCRIPTION A. This section includes materials, testing, and installation of precast concrete manholes, manhole bases, manhole frames, and covers. 1.2 RELATED WORK SPECIFIED ELSEWHERE

More information

Pre-Sloped Drain System

Pre-Sloped Drain System SportsEdge PolyDrain Pre-Sloped Drain System www.sportsedge.com Quality. Safety. Versatility. Aesthetics. 2 PolyDrain FORMULA www.sportsedge.com ABT, Inc. manufactures PolyDrain trench drains; the standard

More information

SECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS

SECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS SECTION D2 MANHOLES AND CATCH BASINS GENERAL This section covers the installation of new manholes, catch basins, drop inlets, drywall structures and the installation of hoods in existing catch basins.

More information

Appendix J: Storm Conveyance Design Parameters

Appendix J: Storm Conveyance Design Parameters Appendix J: Storm Conveyance Design Parameters Drain Commissioner 39 February 2005 STORM DRAINAGE DESIGN CRITERIA A. STORM SEWERS 1. The required discharge capacity shall be determined by the Rational

More information

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INSTALL MANHOLE LIDS FLUSH WITH EXISTING GROUND SURFACE.

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment

More information

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems. The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains

More information

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems. The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains

More information

Facility Sanitary Sewers

Facility Sanitary Sewers University of New Hampshire University of New Hampshire Scholars' Repository Division 22 Plumbing Chapter 5 Technical Construction and Renovation Standards 4-23-2015 221313 - Facility Sanitary Sewers Sandra

More information

Selection, installation and USage of HatcHeS

Selection, installation and USage of HatcHeS Selection, installation and USage of HatcHeS Tech NoTe Hatches for utility structures are manufactured from cast iron, aluminum and steel. The casting requirements, in regard to concrete cover and required

More information

SECTION STORM DRAINAGE SYSTEM Excavating, Backfilling, and Compaction for Utilities Cast-in-place Concrete.

SECTION STORM DRAINAGE SYSTEM Excavating, Backfilling, and Compaction for Utilities Cast-in-place Concrete. SECTION 02720 STORM DRAINAGE SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02221 - Excavating, Backfilling, and Compaction for Utilities. 2. 03300 - Cast-in-place Concrete. 1.02 REFERENCES

More information

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE PART 1 GENERAL 1.1 WORK INCLUDED Specifies requirements for construction and performance of an underground stormwater quality

More information

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. SECTION 33 05 13 MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. B. Related Sections: 1. Section 03 20 00 - Concrete

More information

Civil and Structural Engineering CONSTRUCTION OF BRIDGE STRUCTURES SHALL BE IN ACCORDANCE WITH THE FOLLOWING SPECIFICATIONS, LISTED IN ORDER OF PRECEDENCE: 1. CDOT STANDARD SPECIFICATIONS FOR ROAD AND

More information

SECTION PUBLIC WATER SERVICE CONNECTIONS

SECTION PUBLIC WATER SERVICE CONNECTIONS SECTION 33 14 14 PUBLIC WATER SERVICE CONNECTIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe and fittings for water service connections to small commercial, light industrial, and residential

More information

Use of Grade 80 Reinforcement in Oregon

Use of Grade 80 Reinforcement in Oregon Use of Grade 80 Reinforcement in Oregon Craig Shike, PE Bridge Operations & Standards Managing Engineer PRESENTATION OUTLINE Material Properties of High Strength Reinforcement Recent Grade 80 Research

More information

GENERAL UTILITIES REQUIREMENTS

GENERAL UTILITIES REQUIREMENTS 33 00 00 GENERAL UTILITIES REQUIREMENTS i. 01 41 26.02 Local Utility Information & Locate ii. 23 05 19 Meters and Gages iii. 33 10 00 Water Utilities Public Water Distribution System iv. 33 12 13.13 Water

More information

Summary of the 2011 Changes

Summary of the 2011 Changes The following is a list of amendments to the Residential Site Improvement s, N.J.A.C. 5:21, adopted in 2011. The Notice of Adoption of these changes appeared in the New Jersey Register on May 16, 2011.

More information

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

***************************************************************************************************************

*************************************************************************************************************** 02720 STORM DRAINAGE SYSTEM *************************************************************************************************************** SPECIFIER: CSI MasterFormat 2004 number 33 40 00. ***************************************************************************************************************

More information

SECTION UTILITY MANHOLES AND STRUCTURES

SECTION UTILITY MANHOLES AND STRUCTURES SECTION 33 05 14 UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Precast reinforced concrete manholes and structures with tongue-and-groove joints with masonry transition

More information

Chapter 5 Hydraulic Structures

Chapter 5 Hydraulic Structures Chapter 5 Hydraulic Structures 5.1 Flow Splitter Designs 5.1.1 General Design Criteria A flow splitter must be designed to deliver the WQ design flow rate specified in this volume to the WQ treatment facility.

More information

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS PART 3 - STANDARDS FOR SEWERAGE FACILITIES 3.3 - DESIGN OF STORM SEWERS 3.301 Design of Storm Sewers A. General Information B. Investigations and Surveys C. Special Projects 3.302 Design Criteria for Storm

More information

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details Changes for the 2017 TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details The following changes are made to the existing standards and details to clarify or improve existing information.

More information

SECTION STORM DRAINAGE

SECTION STORM DRAINAGE SECTION 02720 STORM DRAINAGE PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of storm drains and appurtenances. E. Installation

More information

SECTION 02605 MANHOLE AND CATCH BASIN STRUCTURES 1.01 SECTION INCLUDES...1 1.02 RELATED REQUIREMENTS...1 1.03 REFERENCES...1 1.04 SUBMITTALS...2 2.01 PRECAST CONCRETE ITEMS...2 2.02 CASTINGS...3 2.03 MORTAR...3

More information

SECTION SANITARY WASTE INTERCEPTORS

SECTION SANITARY WASTE INTERCEPTORS SECTION 22 13 23 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section

More information

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04 UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04 1. Description This work shall consist of the design, manufacture and construction of a T-WALL structure

More information

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1 Section 7 Roadway GENERAL REQUIREMENTS...7-1 I. TYPICAL SECTION...7-1 7.1 LANE WIDTHS...7-1 7.2 SHOULDER WIDTHS...7-1 7.3 CROSS SLOPE...7-2 7.4 CURB AND UNDERDRAINS...7-2 7.5 SIDEWALKS AND DRIVEWAYS...7-2

More information

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING STANDARD CONSTRUCTION DETAILS REVISED MARCH 2018 GENERAL NOTES EMBEDMENT DETAILS EMBEDMENT DETAILS TWO-WAY CLEANOUT - EXISTING LATERAL TWO-WAY CLEANOUT - NEW CONSTRUCTION TYPICAL SEWER HOUSE SERVICE CONNECTION

More information

SECTION ELECTRICAL UTILITY SERVICES

SECTION ELECTRICAL UTILITY SERVICES SECTION 33 71 73 ELECTRICAL UTILITY SERVICES PART 1 GENERAL 1.1 REFERENCES A. American Association of State Highway Officials (AASHO): 1. Standard Specifications B. California Administrative Code (CAC):

More information

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa). SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 33 40 00 Storm Drainage 1. Introduction A. Duke University is divided into the main areas of the Medical Center, West Campus, Central Campus, and East Campus. The University also includes the Washington

More information

Structural Technical Report 1 Structural Concepts/ Structural Existing Conditions Report

Structural Technical Report 1 Structural Concepts/ Structural Existing Conditions Report Kelly M. Sadusky The Food Science Building Oct. 6, 2004 Professor Parfitt University Park, PA Structural Option Executive Summery: Structural Technical Report 1 Structural Concepts/ Structural Existing

More information

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities ADDENDUM NO. TO Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities Date of Addendum: December, 00 Hethcoat & Davis, Inc. 78 Franklin Road,

More information

How Loads Are Distributed

How Loads Are Distributed LOAD DISTRIBUTION 1 LOAD DISTRIBUTION This section illustrate how load will transmit from the deck to the stringers. Determining the fraction of load carried by a loaded member and the remainder distributed

More information

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes Precast roof slabs refer Standard Drawing CMDG-D-03 Special cast iron cover and frame, refer Service Authority. Special cast iron cover and frame, refer Service Authority. Cast iron cover and frame Ø 200

More information

A 2" MICHIGAN DEPARTMENT OF TRANSPORTATION. 1" (Min.) \ Bracket to \ bottom chord. 24-3" (Max.) 45 (Typ.) * W40 x 149. or l5 x 5 x 1/2 (see

A 2 MICHIGAN DEPARTMENT OF TRANSPORTATION. 1 (Min.) \ Bracket to \ bottom chord. 24-3 (Max.) 45 (Typ.) * W40 x 149. or l5 x 5 x 1/2 (see For Information Only This Type of Support Has Varies To Be Analyzed For Each Case. 1/2 Detail A 2-6" (Max.) 3/8 5/8 " Stiffener \ Column 3/4 " Plate 7/16 7/16 24 - (Max.) to \ bottom chord * 1/4 1 1/ Plate

More information

DESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM

DESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM Istanbul Bridge Conference August 11-13, 2014 Istanbul, Turkey DESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM T. C. NEEL and K.BOZKURT ABSTRACT This work shall consist of the design, manufacture

More information

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

ONE PIPE LENGTH MAX (REFER TO 1/4/FT SLOPE (MIN) 5'-0 (MIN) OR 4 LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4x6 REFER TO TYPICAL EXCAVATION, VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE

More information

TECHNICAL SPECIFICATIONS KNOX MCRAE BAFFLE BOX

TECHNICAL SPECIFICATIONS KNOX MCRAE BAFFLE BOX Prepared for CITY OF TITUSVILLE PUBLIC WORKS DEPARTMENT 2910 Garden Street Titusville, FL 32796 TECHNICAL SPECIFICATIONS KNOX MCRAE BAFFLE BOX, Florida Prepared by 6770 South Washington Avenue Suite 3

More information

SECTION PRECAST CONCRETE MANHOLES

SECTION PRECAST CONCRETE MANHOLES SECTION 03 48 10 PRECAST CONCRETE MANHOLES PART 1: GENERAL 1.01 SECTION INCLUDES A. Precast concrete manholes for sanitary sewers and water lines or as indicated on the Drawings. B. Precast concrete sanitary

More information

Section [ ] Storm Water Treatment Device

Section [ ] Storm Water Treatment Device PART 1 GENERAL Section [ ] Storm Water Treatment Device 01.01.00 Purpose The purpose of this specification is to establish generally acceptable criteria for Storm Water Treatment Devices (SWTD) that treat

More information

MagnumStone Specifications Gravity

MagnumStone Specifications Gravity MagnumStone Specifications Gravity SPECIFICATION FOR MAGNUMSTONE GRAVITY MECHANICALLY STABILIZED EARTH SYSTEM PART 1: GENERAL.01Description The work consists of supplying and installing all aspects of

More information

TECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania

TECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania TECHNICAL REPORT 1 Structural Concepts / Structural Existing Conditions Penn State Hershey Medical Center Children s Hospital Matthew V Vandersall The Pennsylvania State University Architectural Engineering

More information

ULTRA FLO Storm Sewer Pipe

ULTRA FLO Storm Sewer Pipe ULTRA FLO Storm Sewer Pipe Customer Proven Innovation 1 Superior System Hydraulics CONTECH ULTRA FLO has a long history of proven performance on municipal, transportation, airport, shopping center and

More information

Special Specification 6186 Intelligent Transportation System (ITS) Ground Box

Special Specification 6186 Intelligent Transportation System (ITS) Ground Box Special Specification Intelligent Transportation System (ITS) Ground Box 1. DESCRIPTION 2. MATERIALS Construct, furnish, install or remove Intelligent Transportation System (ITS) ground boxes for fiber

More information

A. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components:

A. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components: SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.I RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION PRECAST CONCRETE BIOSOLIDS STORAGE TANK

SECTION PRECAST CONCRETE BIOSOLIDS STORAGE TANK PART 1 GENERAL 1.1 Summary SECTION 13200 PRECAST CONCRETE BIOSOLIDS STORAGE TANK A. Biosolids Storage Tank 1.2 System Description A. Precast concrete storage tank with precast concrete roof, beams, columns,

More information

Lifetime Guaranteed Construction with unique built-in installation and maintenance features

Lifetime Guaranteed Construction with unique built-in installation and maintenance features Lifetime Guaranteed Construction with unique built-in installation and maintenance features Great Basin grease interceptors provide the best in quality materials and engineered craftsmanship. Units are

More information

(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No.

(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No. (SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No. Special Provision No. 407S06 July 2010 Aggregate Requirements, Lift Rings,

More information

PART 1 COMMON FOR WATER & WASTEWATER CONSTRUCTION TITLE By Other Than Open Cut (Non-T.x.D.O.T. - Non Railroad) --- 101 Highway Crossing - All Wastewater Mains & Water Mains 12" and Smaller in Diameter.

More information

Pulaski County, Virginia

Pulaski County, Virginia Pulaski County, Virginia Typical Retaining Wall Details Based on the 2009 International Residential Code CONTENTS Timber Retaining Wall... 2 General Requirements... 2 Wall Construction... 2 Deadmen...

More information

HIGH RISE CONDO SOHO, NEW YORK, NY

HIGH RISE CONDO SOHO, NEW YORK, NY HIGH RISE CONDO SOHO, NEW YORK, NY TECHNICAL ASSIGNMENT 1 October 5, 2006 Joseph The Pennsylvania State University Structural Option Faculty Advisor: Andres Lepage TABLE OF CONTENTS TABLE OF CONTENTS 2

More information

MultiDrain Systems, Inc. #12 EconoDrain and EconoDrain PT-3 Hydraulic Data. We drain your site, not your budget!

MultiDrain Systems, Inc. #12 EconoDrain and EconoDrain PT-3 Hydraulic Data. We drain your site, not your budget! #12 EconoDrain and EconoDrain PT-3 Hydraulic Data MultiDrain Systems, Inc. We drain your site, not your budget! Copyright July 2008 MultiDrain Systems, Inc. System and Hydraulic Data: # 12 EconoDrain and

More information

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED HDPE PRODUCTS LANE S HDPE DRAINAGE PIPE Lane provides the complete product line to meet all your HDPE drainage needs - the full range of diameters,

More information

BAYFILTER SPECIFICATIONS

BAYFILTER SPECIFICATIONS PART 1.00 GENERAL 1.1 DESCRIPTION BAYFILTER SPECIFICATIONS A. The BayFilter system s internal components manufacturer selected by the Contractor and approved by the Engineer, shall furnish all labor, materials,

More information

New Jersey Turnpike Authority

New Jersey Turnpike Authority New Jersey Turnpike Authority DOCUMENT UPDATE REQUEST Forward to Assistant Chief Engineer, Design Initiator Russell Saputo, PE Submittal Date 6/21/16 Firm Stantec Consulting Services Inc. Telephone 201-587-9040

More information

MultiDrain Systems, Inc. #8 EconoDrain and EconoDrain PT-3 Hydraulic Data. We drain your site, not your budget!

MultiDrain Systems, Inc. #8 EconoDrain and EconoDrain PT-3 Hydraulic Data. We drain your site, not your budget! #8 EconoDrain and EconoDrain PT-3 Hydraulic Data MultiDrain Systems, Inc. We drain your site, not your budget! Copyright July 2008 MultiDrain Systems, Inc. System and Hydraulic Data: # 8 EconoDrain and

More information

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity System Codes and Criteria Design Codes and Standards The design code used is the Wisconsin Administrative Code along with the State of Wisconsin Department of Commerce-Safety & Buildings Chapters Comm

More information