Environmental Products. Designed to Protect and Improve Our Environment. Delivering Reliability
|
|
- Valerie White
- 6 years ago
- Views:
Transcription
1 Delivering Reliability A Designed to Protect and Improve Our Environment Environmental Products Sales & Service 888-9Oldcastle ( )
2 A Environmentally Responsible COVER & FRAME Oldcastle Precast to the Rescue All of our products are produced in a controlled environment helping us maintain the high standards implemented by Oldcastle Precast. Many of our products are specifically designed to protect and improve the environment. We re always looking for new ways to minimize waste, increase recycling, improve energy management and use eco-friendly materials. FINISH:Hot Dip Galvanized after Fabrication. FRAME:Can be Fabricated for Cast-In Applications. LOADING:Designed for H20 loading for Non Roadway Applications. DOORS: Offered in Single, Double, or Triple Configurations, open 180 Degrees. EMBEDDED LIFTERS MATERIAL:Carbon Steel LOADING:Offered in 2, 4, 8, & 20 Ton 1 Ton Universal Lifters also available. Material and Design Loads The structural notes below are for standard models. We can design vaults to meet other specifications. 1. Concrete 5000psi (35 28 days. 2. Rebar ASTM A 615 grade 60 rebar. 3. Mesh Welded Wire Fabric ASTM A185 grade Design Building Code Requirements for Reinforced Concrete (ACI ) including all referenced standards and specifications. AASHTO Standard Specifications for Highway Bridges - 16th edition. 5. Loads Dead Load: Concrete PCF Earth Cover PCF Lateral Earth Pressure on walls: Equivalent Fluid pressure above water table PSF per foot of depth. Equivalent Fluid pressure below water table PSF per foot of depth. Surcharge on walls + 2 feet of earth cover Live Load: AASHTO HS ,000 lbs. rear axle loading GRADE RINGS / RISERS FINISH:Concrete with various Coatings/Textures. Designed to bring Covers up to Grade. Can be Rectangular or Round. Suitable for Off-Street Traffic. INLET PIPE Supplied by others SLUDGE WEIR Weight Varies by size FACET M-PAC Coalescing Media Shown with (3) rows We can provide drawings and calculations stamped by a Professional Engineer.
3 Environmental Vaults Sales & Service SINGLE GREASE INTERCEPT Can be Fabricated in a variety of Sizes. MANHOLE COVER & FRAME MATERIAL:Cast or Ductile Iron. DESIGNS:Custom Lettering & Design available. LOADING:Built to an H20 rating up to 150 KIP. SIZES: 24, 30, 32, 36 Round OIL WEIR Weight Varies by Size OUTLET PIPE Supplied by Others Size Varies by vault type OUTLET WEIR Weight Varies by size
4 Oil/Water Separator Vault Oil & Water Separator Vaults We offer a wide range of oil & water separator vaults to meet the specific application needs of our customers. From smaller capacity 35 GPM (gallon per minute) vaults, to larger capacity 800 GPM vaults and everything in between.
5 Sales & Service Grease Interceptor Vault Single Grease Interceptor Vault We offer grease interceptors that can be desinged and configured to meet a wide range of commercial applications as well as soecific performance criteria. LID SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. DESIGNED FOR AASHTO HS-20 LOADING BASE SECTION SPECIAL ACCESSES, CASTOUTS, KNOCKOUTS, ETC. can be placed as specified. DESIGNED FOR AASHTO HS-20 LOADING DESIGNED ACCORDING TO ASTM C AND ASTM C858-83s. *Grease Interceptor vaults are available in a variety of standard and custom sizes to suit virtually any application.
6 Sand/Oil Interceptor Vault Sand & Oil interceptor Vault We offer a wide range of sand & oil interceptor vaults to meet the specific application needs of our customers. From smaller 320 gallon capacity vaults, to larger GPM capacity vaults and everything in between. LID SECTION ACCESS OPENING-Can be any size and location. INVERTED RING & COVER as well as STEEL or ALUMINUM HATCHES can also be cast in. DESIGNED FOR AASHTO HS-20 LOADING Retaining Baffle for Sand Interceptor BASE SECTION SPECIAL ACCESSES, CASTOUTS, KNOCKOUTS, ETC. can be placed as specified. DESIGNED FOR AASHTO HS-20 LOADING DESIGNED ACCORDING TO ASTM C AND ASTM C858-83s. *Sand & Oil vaults are available in a variety of standard and custom sizes to suit virtually any application.
7 Sales & Service Interceptor Vaults Standard Sizes for Interceptor Vaults We offer a wide range of standard sized interceptor vaults to meet the specific application needs of our customers. From smaller capacity 320 Gallon vaults, to larger capacity 11,000 Gallon vaults and everything in between. Elevation Plan STANDARD INTERCEPTOR VAULTS Gallon Capacity MODEL A B C D E F WEIGHT SI ,535 LBS SI ,631 LBS SI ,031 LBS SI ,231 LBS SI ,431 LBS SI ,831 LBS SI ,031 LBS SI ,231 LBS SI ,529 LBS SI ,454 LBS SI ,521 LBS SI ,702 LBS SI ,964 LBS SI ,462 LBS SI ,883 LBS SI ,708 LBS SI ,451 LBS SI ,949 LBS SI ,692 LBS
8 Environmental Delivering Reliability A Oldcastle Precast Oldcastle Precast is the leading manufacturer of precast concrete, polymer concrete, and plastic products in the United States. With a nationwide network of facilities, our products are always close at hand. Our employees are committed to upholding core values of reliability, quality, and service in revolutionary ways. Our attention to detail exceeds the expectations of customers from some of the largest companies in the U.S., across a spectrum of industries. Sales & Service Oldcastle ( ) 2010 Oldcastle Precast, Inc. V1_121409
Inlets & Catch Basins
A Delivering Reliability Inlets & Catch Basins Water-Conveyance & Drainage A Environmentally Responsible Oldcastle Precast to the Rescue All of our products are produced in a controlled environment helping
More informationDelivering Reliability. Electrical Vaults. Power & Energy-Underground Structures
A Delivering Reliability Electrical Vaults Power & Energy-Underground Structures A The Benefits of Precast Vaults Electrical vaults house power cables and transformers, and are a preferred alternative
More information16. Design of Pipeline Structures.
16. Design of Pipeline Structures. a. General. 1) The following guidelines are for the design of structures for water and sewer pipelines including structural concrete and miscellaneous metals design.
More informationEffective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid
Section I: Castings and Aluminum Covers I 1 I 2 I 3 I 4 Valve Boxes Service Clean-out Box and Lid Manhole Casting/ Standard Ring and Cover Access Covers/ Aluminum 1 I 1 VALVE BOXES: Valve boxes shall meet
More information401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply:
SECTION 400 SANITARY SEWER SYSTEM The design of sanitary sewers shall be in conformance with the applicable sections of the State of Washington, Department of Ecology manual, Criteria for Sewage Works
More informationMANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems
SECTION 02607-1 1.0 GENERAL 1.1 SCOPE: A. This section covers the work necessary for the construction of sanitary and storm system manholes, catch basins, and miscellaneous concrete structures complete.
More information400 Gal. Grease Interceptor
400 Gal. Grease Interceptor PC-000-331 Secondary chamber volume equal to 1/2 total capacity. Verify compliance with local regulations. STM-C-478 specifications for water and wastewater structures. utyl
More informationTRENCH SYSTEM Pedestrian channels are rated for 200 lbs./ft 2 Pedestrian channels are rated for 200 lbs./ft 2 8012 (10X10) 12" 10" 10" 10" 8022 (20X20) 12" 20" 20" 20" 8026 (24X24) 12" 24" 24" 24"
More information2.1.2 Minimum wall thickness shall be 90 mm Frames and covers shall be bitumen coated by dipping.
1.0 GENERAL 1.1 Scope 2.0 PRODUCTS 1.1.1 The work shall consist of the construction, renovation or the adjustment of manholes and/or catchbasins as detailed on the plans or where designated by the Engineer
More informationPERMANENT PAVEMENT REPAIR NO SCALE
SAWCUT EXISTING PAVEMENT 2" BITUMINOUS CONCRETE SURFACE COURSE, CLASS 2 (MIN) CLEAN EDGE PRIOR TO PAVING AND PAINT WITH LIQUID BITUMEN. INSTALL SEALANT OVER JOINT UPON COMPLETION 2" BITUMINOUS CONCRETE
More informationUniversity of Delaware
University Contact: Energy & Engineering Group (302) 831-1744 SECTION 03 45 00_PRECAST CONCRETE STRUCTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the contract, including
More informationZG Scope. 2 Applicable Documents. 3 General. 4 Stock Item Numbers. Padvault Single-Phase Residential, 2.1 PacifiCorp Material Specifications
1 Scope This specification outlines the minimum requirements for a 48 48 padvault for single-phase primary service. Single-phase transformers and sectionalizers (elbow switched cabinets) can be mounted
More informationQualified Product Policy 15 Drainage Structure Miscellaneous Components Qualified Product List 14 [G] Heavy Duty Gray Cast Iron
SCDOT Qualified Product Policy 15 1 SOUTH CAROLINA DEPARTMENT OF TRANSPORTATION Drainage Structure Miscellaneous Components (See also QPL14 for precast drainage structure components) This policy covers
More informationStorm Drainage
University of New Hampshire University of New Hampshire Scholars' Repository Division 33 Utilities Chapter 5 Technical Construction and Renovation Standards 4-23-2015 334100 - Storm Drainage Sandra Hickey
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-33 16 13.16 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-13208 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationSECTION XXXX POLYMER CONCRETE PUMP STATIONS
SECTION XXXX POLYMER CONCRETE PUMP STATIONS PART 1 GENERAL 1.1 SUMMARY A. This specification shall govern for the furnishing of all work necessary for installation of polymer concrete pump stations to
More information3/23/2016. Happy Pi Day! What We Will Discuss. Best Practices for Precast Concrete Tank Inspections
Best Practices for Precast Concrete Tank Inspections 29 th Annual GSDI Spring Septic System Conference & Expo Monday March 14, 2016 Claude Goguen, PE, LEED AP, National Precast Concrete Association Happy
More informationCONCRETE TECHNOLOGY CORPORATION
PRECAST, PRESTRESSED HOLLOW CORE SLABS DESIGN CRITERIA & SPAN-LOAD CHARTS FOR STORM WATER DETENTION VAULT LIDS (CHARTS REVISED /18/08) Introduction Design Criteria for Development of the Span-Load Charts
More informationAMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS
Works and Emergency Services CITY OF TORONTO WATER AND WASTEWATER SERVICES STANDARD CONSTRUCTION SPECIFICATIONS TS 408 November 2010 AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING
More informationSECTION PRECAST CONCRETE MANHOLES
SECTION 02601 PRECAST CONCRETE MANHOLES PART 1 GENERAL 1.1 The work specified in this section shall include the furnishing, hauling, and placing of all precast manholes shown on the drawings and as specified
More informationTYPE "A" CATCH BASIN
27" 1.67' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3250-BV OR APPROVED EQUAL. "INFI SHIELD" SEAL OR APPROVED EQUAL RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE,
More informationTCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II
SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationMiscellaneous and Cast Iron Listings
aeconcrete.com May 2017 Miscellaneous and Cast Iron Listings Drawing Number Item Description Product Size (Length X Width X Depth in mm) SVVZ-20-SUMP-C Drainage Sump w/ Cover 660 x 510 x 765 i.d. SVVZ-NC-SUMP-C
More informationWWR For Structural Applications A Discussion of Current Product Knowledge and Practices
TF 208-R-08 WWR For Structural Applications A Discussion of Current Product Knowledge and Practices INTRODUCTION With its greater strength, generally higher ductility, and significantly lower placing and
More informationThe Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.
The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains
More informationCurrent Standard Plates including Transmittal Letters are available on the web at:
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (6-03) MANUAL: Standard
More informationAppendix J: Structural Engineering
Bass Ponds, Marsh, and Wetland Habitat Rehabilitation and Enhancement Project Feasibility Report and Integrated Environmental Assessment Upper Mississippi River Restoration Program January, 2019 TABLE
More informationPASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017
SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationOVERALL STRUCTURAL SYSTEM
EXECUTIVE SUMMARY The at the Pittsburgh International Airport, PA, is a 275,000 square foot multi-use building located directly adjacent to the airport s landside terminal. The building consists of an
More informationSection 10 Design Criteria: Components
1. Tanks and Vaults Section 10 Design Criteria: Components a. Watertightness i. Septic tanks, vaults, dosing tanks, other treatment components, risers and lids must not allow infiltration of ground water
More informationPIPE CULVERTS. Construct pipe culverts, beveled ends, pipe aprons, and associated appurtenances.
PIPE CULVERTS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe Culverts B. Pipe Aprons and Beveled Ends C. Footings for Concrete Pipe Aprons D. Pipe Apron Guards 1.02 DESCRIPTION OF WORK Construct pipe culverts,
More informationPRECAST CONCRETE ON-SITE WASTEWATER TANKS
PRECAST CONCRETE ON-SITE WASTEWATER TANKS OUTLINE Purpose Precast Advantage Design Goals Applicable Standards Structural Design Materials Production Watertightness Installation NPCA Plant Certification
More informationSPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings
1993 Specifications CSJ 0144-01-060 SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings 1. General. (1) Scope. This Section includes the furnishing, installation, and subsequent
More informationSECTION GROUND WATER STORAGE TANKS
SECTION 33 16 13 GROUND WATER STORAGE TANKS PART 1: GENERAL 1.01 SCOPE A. Section includes requirements for designing, fabricating, and erecting a welded steel ground storage tank. 1.02 SYSTEM DESCRIPTION
More informationIAPMO Z yy. Rainwater Harvesting Tanks. 1 Scope. 2 Reference Publications
Standards Action - February 10, 2017 - Page 29 of 40 pages IAPMO Z1002 20yy 1 Scope 1.1 This Standard covers rainwater harvesting tanks and specifies requirements for design, materials, manufacture, performance,
More informationPOST FRAME BUILDING STANDARDS
CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 POST FRAME BUILDING STANDARDS 201.3
More informationCHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION.
Standard Drawings Index NOTE: The specifications for materials and workmanship shall conform to the latest edition or the "Standard Specifications for Public Works Construction" published by the North
More informationSECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS
SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS To prevent the contamination of the public water supplies from nearby sanitary sewers, the following State Water Resources Control Board Division
More informationHydrodynamic Separation Product Calculator
Hydrodynamic Separation Product Calculator Example Project BMP #1 CDS 2015-4 Project Information Project Name Example Project Option # A Country US State Kentucky City Covington Contact Information First
More informationSection G1. Design of Cast-In-Place Box Conduits
G1-1 Economy of Design 1. Height to Width Ratio Section G1 Design of Cast-In-Place Box Conduits Careful economic studies should be made to determine the greatest economy of the entire storm drain. As an
More informationVALLECITOS WATER DISTRICT SECTION PRECAST REINFORCED CONCRETE MANHOLES
PART 1 GENERAL 1.1 DESCRIPTION A. This section includes materials, testing, and installation of precast concrete manholes, manhole bases, manhole frames, and covers. 1.2 RELATED WORK SPECIFIED ELSEWHERE
More informationPre-Sloped Drain System
SportsEdge PolyDrain Pre-Sloped Drain System www.sportsedge.com Quality. Safety. Versatility. Aesthetics. 2 PolyDrain FORMULA www.sportsedge.com ABT, Inc. manufactures PolyDrain trench drains; the standard
More informationSECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS
SECTION D2 MANHOLES AND CATCH BASINS GENERAL This section covers the installation of new manholes, catch basins, drop inlets, drywall structures and the installation of hoods in existing catch basins.
More informationAppendix J: Storm Conveyance Design Parameters
Appendix J: Storm Conveyance Design Parameters Drain Commissioner 39 February 2005 STORM DRAINAGE DESIGN CRITERIA A. STORM SEWERS 1. The required discharge capacity shall be determined by the Rational
More informationNOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST
NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INSTALL MANHOLE LIDS FLUSH WITH EXISTING GROUND SURFACE.
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS
PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment
More informationThe Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.
The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains
More informationThe Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.
The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains
More informationFacility Sanitary Sewers
University of New Hampshire University of New Hampshire Scholars' Repository Division 22 Plumbing Chapter 5 Technical Construction and Renovation Standards 4-23-2015 221313 - Facility Sanitary Sewers Sandra
More informationSelection, installation and USage of HatcHeS
Selection, installation and USage of HatcHeS Tech NoTe Hatches for utility structures are manufactured from cast iron, aluminum and steel. The casting requirements, in regard to concrete cover and required
More informationSECTION STORM DRAINAGE SYSTEM Excavating, Backfilling, and Compaction for Utilities Cast-in-place Concrete.
SECTION 02720 STORM DRAINAGE SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02221 - Excavating, Backfilling, and Compaction for Utilities. 2. 03300 - Cast-in-place Concrete. 1.02 REFERENCES
More informationSTANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE
STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE PART 1 GENERAL 1.1 WORK INCLUDED Specifies requirements for construction and performance of an underground stormwater quality
More informationSECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.
SECTION 33 05 13 MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. B. Related Sections: 1. Section 03 20 00 - Concrete
More informationCivil and Structural Engineering CONSTRUCTION OF BRIDGE STRUCTURES SHALL BE IN ACCORDANCE WITH THE FOLLOWING SPECIFICATIONS, LISTED IN ORDER OF PRECEDENCE: 1. CDOT STANDARD SPECIFICATIONS FOR ROAD AND
More informationSECTION PUBLIC WATER SERVICE CONNECTIONS
SECTION 33 14 14 PUBLIC WATER SERVICE CONNECTIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe and fittings for water service connections to small commercial, light industrial, and residential
More informationUse of Grade 80 Reinforcement in Oregon
Use of Grade 80 Reinforcement in Oregon Craig Shike, PE Bridge Operations & Standards Managing Engineer PRESENTATION OUTLINE Material Properties of High Strength Reinforcement Recent Grade 80 Research
More informationGENERAL UTILITIES REQUIREMENTS
33 00 00 GENERAL UTILITIES REQUIREMENTS i. 01 41 26.02 Local Utility Information & Locate ii. 23 05 19 Meters and Gages iii. 33 10 00 Water Utilities Public Water Distribution System iv. 33 12 13.13 Water
More informationSummary of the 2011 Changes
The following is a list of amendments to the Residential Site Improvement s, N.J.A.C. 5:21, adopted in 2011. The Notice of Adoption of these changes appeared in the New Jersey Register on May 16, 2011.
More informationNew Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M
SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information***************************************************************************************************************
02720 STORM DRAINAGE SYSTEM *************************************************************************************************************** SPECIFIER: CSI MasterFormat 2004 number 33 40 00. ***************************************************************************************************************
More informationSECTION UTILITY MANHOLES AND STRUCTURES
SECTION 33 05 14 UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Precast reinforced concrete manholes and structures with tongue-and-groove joints with masonry transition
More informationChapter 5 Hydraulic Structures
Chapter 5 Hydraulic Structures 5.1 Flow Splitter Designs 5.1.1 General Design Criteria A flow splitter must be designed to deliver the WQ design flow rate specified in this volume to the WQ treatment facility.
More informationPART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS
PART 3 - STANDARDS FOR SEWERAGE FACILITIES 3.3 - DESIGN OF STORM SEWERS 3.301 Design of Storm Sewers A. General Information B. Investigations and Surveys C. Special Projects 3.302 Design Criteria for Storm
More informationChanges for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details
Changes for the 2017 TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details The following changes are made to the existing standards and details to clarify or improve existing information.
More informationSECTION STORM DRAINAGE
SECTION 02720 STORM DRAINAGE PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of storm drains and appurtenances. E. Installation
More informationSECTION 02605 MANHOLE AND CATCH BASIN STRUCTURES 1.01 SECTION INCLUDES...1 1.02 RELATED REQUIREMENTS...1 1.03 REFERENCES...1 1.04 SUBMITTALS...2 2.01 PRECAST CONCRETE ITEMS...2 2.02 CASTINGS...3 2.03 MORTAR...3
More informationSECTION SANITARY WASTE INTERCEPTORS
SECTION 22 13 23 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section
More informationUPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04
UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04 1. Description This work shall consist of the design, manufacture and construction of a T-WALL structure
More informationSection 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1
Section 7 Roadway GENERAL REQUIREMENTS...7-1 I. TYPICAL SECTION...7-1 7.1 LANE WIDTHS...7-1 7.2 SHOULDER WIDTHS...7-1 7.3 CROSS SLOPE...7-2 7.4 CURB AND UNDERDRAINS...7-2 7.5 SIDEWALKS AND DRIVEWAYS...7-2
More informationSTANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING
STANDARD CONSTRUCTION DETAILS REVISED MARCH 2018 GENERAL NOTES EMBEDMENT DETAILS EMBEDMENT DETAILS TWO-WAY CLEANOUT - EXISTING LATERAL TWO-WAY CLEANOUT - NEW CONSTRUCTION TYPICAL SEWER HOUSE SERVICE CONNECTION
More informationSECTION ELECTRICAL UTILITY SERVICES
SECTION 33 71 73 ELECTRICAL UTILITY SERVICES PART 1 GENERAL 1.1 REFERENCES A. American Association of State Highway Officials (AASHO): 1. Standard Specifications B. California Administrative Code (CAC):
More informationA. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).
SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationDUKE UNIVERSITY CONSTRUCTION STANDARDS
1 33 40 00 Storm Drainage 1. Introduction A. Duke University is divided into the main areas of the Medical Center, West Campus, Central Campus, and East Campus. The University also includes the Washington
More informationStructural Technical Report 1 Structural Concepts/ Structural Existing Conditions Report
Kelly M. Sadusky The Food Science Building Oct. 6, 2004 Professor Parfitt University Park, PA Structural Option Executive Summery: Structural Technical Report 1 Structural Concepts/ Structural Existing
More informationADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities
ADDENDUM NO. TO Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities Date of Addendum: December, 00 Hethcoat & Davis, Inc. 78 Franklin Road,
More informationHow Loads Are Distributed
LOAD DISTRIBUTION 1 LOAD DISTRIBUTION This section illustrate how load will transmit from the deck to the stringers. Determining the fraction of load carried by a loaded member and the remainder distributed
More informationAPPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes
Precast roof slabs refer Standard Drawing CMDG-D-03 Special cast iron cover and frame, refer Service Authority. Special cast iron cover and frame, refer Service Authority. Cast iron cover and frame Ø 200
More informationA 2" MICHIGAN DEPARTMENT OF TRANSPORTATION. 1" (Min.) \ Bracket to \ bottom chord. 24-3" (Max.) 45 (Typ.) * W40 x 149. or l5 x 5 x 1/2 (see
For Information Only This Type of Support Has Varies To Be Analyzed For Each Case. 1/2 Detail A 2-6" (Max.) 3/8 5/8 " Stiffener \ Column 3/4 " Plate 7/16 7/16 24 - (Max.) to \ bottom chord * 1/4 1 1/ Plate
More informationDESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM
Istanbul Bridge Conference August 11-13, 2014 Istanbul, Turkey DESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM T. C. NEEL and K.BOZKURT ABSTRACT This work shall consist of the design, manufacture
More informationONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,
VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE
More informationTECHNICAL SPECIFICATIONS KNOX MCRAE BAFFLE BOX
Prepared for CITY OF TITUSVILLE PUBLIC WORKS DEPARTMENT 2910 Garden Street Titusville, FL 32796 TECHNICAL SPECIFICATIONS KNOX MCRAE BAFFLE BOX, Florida Prepared by 6770 South Washington Avenue Suite 3
More informationSECTION PRECAST CONCRETE MANHOLES
SECTION 03 48 10 PRECAST CONCRETE MANHOLES PART 1: GENERAL 1.01 SECTION INCLUDES A. Precast concrete manholes for sanitary sewers and water lines or as indicated on the Drawings. B. Precast concrete sanitary
More informationSection [ ] Storm Water Treatment Device
PART 1 GENERAL Section [ ] Storm Water Treatment Device 01.01.00 Purpose The purpose of this specification is to establish generally acceptable criteria for Storm Water Treatment Devices (SWTD) that treat
More informationMagnumStone Specifications Gravity
MagnumStone Specifications Gravity SPECIFICATION FOR MAGNUMSTONE GRAVITY MECHANICALLY STABILIZED EARTH SYSTEM PART 1: GENERAL.01Description The work consists of supplying and installing all aspects of
More informationTECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania
TECHNICAL REPORT 1 Structural Concepts / Structural Existing Conditions Penn State Hershey Medical Center Children s Hospital Matthew V Vandersall The Pennsylvania State University Architectural Engineering
More informationULTRA FLO Storm Sewer Pipe
ULTRA FLO Storm Sewer Pipe Customer Proven Innovation 1 Superior System Hydraulics CONTECH ULTRA FLO has a long history of proven performance on municipal, transportation, airport, shopping center and
More informationSpecial Specification 6186 Intelligent Transportation System (ITS) Ground Box
Special Specification Intelligent Transportation System (ITS) Ground Box 1. DESCRIPTION 2. MATERIALS Construct, furnish, install or remove Intelligent Transportation System (ITS) ground boxes for fiber
More informationA. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components:
SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.I RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSECTION PRECAST CONCRETE BIOSOLIDS STORAGE TANK
PART 1 GENERAL 1.1 Summary SECTION 13200 PRECAST CONCRETE BIOSOLIDS STORAGE TANK A. Biosolids Storage Tank 1.2 System Description A. Precast concrete storage tank with precast concrete roof, beams, columns,
More informationLifetime Guaranteed Construction with unique built-in installation and maintenance features
Lifetime Guaranteed Construction with unique built-in installation and maintenance features Great Basin grease interceptors provide the best in quality materials and engineered craftsmanship. Units are
More information(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No.
(SIZE) MANHOLES CATCH BASINS AND DITCH INLETS -Item No. ADJUSTING AND REBUILDING MANHOLES, CATCH BASINS AND DITCH INLETS - Item No. Special Provision No. 407S06 July 2010 Aggregate Requirements, Lift Rings,
More informationPART 1 COMMON FOR WATER & WASTEWATER CONSTRUCTION TITLE By Other Than Open Cut (Non-T.x.D.O.T. - Non Railroad) --- 101 Highway Crossing - All Wastewater Mains & Water Mains 12" and Smaller in Diameter.
More informationPulaski County, Virginia
Pulaski County, Virginia Typical Retaining Wall Details Based on the 2009 International Residential Code CONTENTS Timber Retaining Wall... 2 General Requirements... 2 Wall Construction... 2 Deadmen...
More informationHIGH RISE CONDO SOHO, NEW YORK, NY
HIGH RISE CONDO SOHO, NEW YORK, NY TECHNICAL ASSIGNMENT 1 October 5, 2006 Joseph The Pennsylvania State University Structural Option Faculty Advisor: Andres Lepage TABLE OF CONTENTS TABLE OF CONTENTS 2
More informationMultiDrain Systems, Inc. #12 EconoDrain and EconoDrain PT-3 Hydraulic Data. We drain your site, not your budget!
#12 EconoDrain and EconoDrain PT-3 Hydraulic Data MultiDrain Systems, Inc. We drain your site, not your budget! Copyright July 2008 MultiDrain Systems, Inc. System and Hydraulic Data: # 12 EconoDrain and
More informationHDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED
HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED HDPE PRODUCTS LANE S HDPE DRAINAGE PIPE Lane provides the complete product line to meet all your HDPE drainage needs - the full range of diameters,
More informationBAYFILTER SPECIFICATIONS
PART 1.00 GENERAL 1.1 DESCRIPTION BAYFILTER SPECIFICATIONS A. The BayFilter system s internal components manufacturer selected by the Contractor and approved by the Engineer, shall furnish all labor, materials,
More informationNew Jersey Turnpike Authority
New Jersey Turnpike Authority DOCUMENT UPDATE REQUEST Forward to Assistant Chief Engineer, Design Initiator Russell Saputo, PE Submittal Date 6/21/16 Firm Stantec Consulting Services Inc. Telephone 201-587-9040
More informationMultiDrain Systems, Inc. #8 EconoDrain and EconoDrain PT-3 Hydraulic Data. We drain your site, not your budget!
#8 EconoDrain and EconoDrain PT-3 Hydraulic Data MultiDrain Systems, Inc. We drain your site, not your budget! Copyright July 2008 MultiDrain Systems, Inc. System and Hydraulic Data: # 8 EconoDrain and
More informationStructural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity
System Codes and Criteria Design Codes and Standards The design code used is the Wisconsin Administrative Code along with the State of Wisconsin Department of Commerce-Safety & Buildings Chapters Comm
More information