1 Florida Department of Transportation CHARLIE CRIST GOVERNOR October 20, South Marion Avenue Lake City, Florida STEPHANIE C. KOPELOUSOS SECRETARY To: Prospective Bidders Addendum No.: 1, E2O98, Financial Project # Roof replacement for Palatka Construction in Putnam County 1. The warranty used for the St Augustine and Jacksonville roofing projects is slightly different than the Duro-Last warranty. We will not be able to make any changes to our Warranty? Please advise if this will be acceptable. ANSWER: I have attached a sample copy of the Duro-Last warranty. A warranty for an alternate material must cover all aspects of the Duro-Last warranty in order to be considered equal. If an alternate manufacturer s standard warranty does not cover all items listed in the Duro-Last warranty, the alternate manufacture will have to attach a rider for any excluded items in order to be considered equal. 2. You were correct sir about the requirement of a gypsum product in order to achieve the UL Class A specified for the 2/5 in 12 slope when using a PVC type application. A UL Class A can be met with a JM Built up asphalt application using specification 4FLG. This would require a nailed base sheet to the existing LWC, three plies of GlasPly premier and flood coat and gravel. This would give you the same type roof you have now, accept the plys would be fiberglass not asbestos. JM can offer a 20 year warranty with this application. A UL Class B can be achieved with the same type application using a Glass Cap sheet in lieu of the gravel. We can coat the Cap sheet with our TopGuard 4000 to achieve a SRI value of 102, if required. ANSWER: A built up asphalt roofing system was not specified for this project and will not be approved as an alternate. 3. Duro-last requires DensDeck roofing board to fully adhere the 60 mil to. (alt 2) DensDeck comes in two thicknesses, 1/4 and 1/2. Which is required on this project? ANSWER: ¼ is acceptable as long as it meets all building code requirements. 4. What is the required o.c. spacing of the Vinyl ribs? ANSWER: 16-inches. 5. Duro-Last recommends their PVC eave drip on re-cover applications. Do we propose Duro-Last PVC eave drip or metal for this application? ANSWER: Edge detail shall be in accordance with project specifications which require a 2-piece compression metal edge manufactured by the roof membrane manufacturer. Finish shall be dark bronze Kynar. You must sign, date and fax a copy of this addendum back to me by close of business today to indicate receipt. The bidder is required to acknowledge the addendum in the space provided on the proposal. Thanks, Company Name Patsy Elkins, CPPB Contracts Coordinator Date Phone: Fax: Signature
2
3 TopGard 4000 Description TopGard 4000 is a multipurpose, 100% acrylic elastomeric coating for use over a variety of substrates, including asphalt, single ply and metal roofing. TopGard 4000 has unique bleed-blocking properties that make it particularly well suited for coating over asphalt surfaces. TopGard 4000 exceeds several ASTM D 6083 requirements for critical properties such as tensile strength, elongation, wet adhesion and weatherability. Use TopGard 4000 is used as an excellent reflective coating over smoothor mineral-surfaced roofing systems on smooth roofs. It can be used over both modified and built-up roofing systems. For best results, this product should not be applied until the roofing membrane has had the opportunity to cure at least 60 days. Application When applying TopGard 4000, use a brush, roller or spray equipment. Make sure that all surfaces are clean, dry and free of any dirt, grease, oil or other debris that may interfere with proper adhesion. It is recommended that TopGard 4000 be applied in two coats. The first coat should be completely dry (normally 4 to 12 hours) before applying the second coat. Temperatures must be 50 F (10 C) and rising during time of application. Do not apply TopGard 4000 within 24 hours of anticipated rain, dew or freezing temperatures. As with any coating, cooler temperatures and high humidity will slow the cure time. Advantages Fully adhered installation Asphalt bleed blocking 100% acrylic durability Energy savings Prolonged roof life Reduced life cycle costs Energy and the Environment Energy Star Pass Reflectivity: 0.83* California Title 24 Pass Reflectivity: 0.83* Emissivity: 0.88 LEED Reflectivity: 0.83* Emissivity: 0.88 Sustainable Sites (credits 5.1, 5.2, 7.1, 7.2) Energy and Atmosphere (prerequisite 2 and credit 1) * Solar Reflectance Index (SRI) is 102. SRI is tested in accordance with ASTM E Approvals UL 790 Class A Rating California State Fire Marshall Coverage Type of Roof Fiber glass felts Smooth-surfaced modified sheets Mineral-surfaced BUR/modified sheets Coverage Rate (per coat)* ft 2 /gal ( m 2 /l) ft 2 /gal ( m 2 /l) ft 2 /gal ( m 2 /l) * Coverage rates depend upon weather conditions and substrate. Refer to specific code agency Web sites for exact construction information. Note: When TopGard 4000 is applied as a two-coat process, total cured coating thickness will be approximately 20 mil (0.5 mm). Packaging 5 gal (18.9 l) pails (approximate weight: 60 lb [27.2 kg]) 55 gal (208 l) drums (approximate weight: 673 lb [305.3 kg]) 275 gal (1,041 l) totes (approximate weight: 3,290 lb [1,492.3 kg]) Shelf Life The shelf life of the TopGard products is one year, provided the cans are unopened and have been stored under moderate conditions. Tested in accordance to ASTM D 6083 Physical Properties Property Value Initial Tensile Strength psi (1.6 MPa) Initial Elongation % Dry Adhesion pli Wet Adhesion pli Tear Resistance lbf/in (18 km/m) 1,000-hr Accelerated Weathering... No cracking or checking Elongation After Accelerated Weathering % Permeance (perms)...12 Water Swelling...26 Fungi Resistance (Zero No Growth)...Zero rating Volume Solids...52% ± 1% Weight Solids...66% ± 1% Viscosity ± 10 Density g/l Weight lb/gal (1.4 kg/l) Non-volatiles (NVMs)...66% ± 1% Refer to the Material Safety Data Sheet and product label prior to using this product. RS (Replaces 5-08)
4
5
BAYBLOCK HT/BAYBLOCK HT BASE
Characterization Properties / Applications Bayblock HT is a technologically advanced, high-solids, alkali resistant, thixotropic,acrylic elastomeric coating. Bayblock HT is formulated for the protection
More information838 Coatings System Specification Single-Ply Restoration (838 SPR)
838 Coatings System Specification Single-Ply Restoration (838 SPR) PART 1 General 1.01 System Description The 838 Single-Ply Restoration System (838 SPR) can be applied to a variety of single-ply manufactures.
More informationSOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY
SOLAR COATING SYSTEMS 2-PLY EMULSION MULSION/A /ACRYLIC SYSTEM Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY Name Address City, State, zip A. Furnish and install a seamless, reinforced
More informationSMOOTH SURFACED BUILT-UP ROOFS WITH ARC SEBS REFLECTIVE ROOF COATINGS
1.0 SCOPE SPECIFICATION FOR COATING SMOOTH SURFACED BUILT-UP ROOFS WITH ARC SEBS REFLECTIVE ROOF COATINGS The intention of this specification is to outline the procedures for the application of ARC SEBS
More informationSection Energy Star & LEED Compliant SPF Roof System Roof System with Acrylic Coating, Aggregate & Cementitious Traffic Topping
Specification Guide Section 07 57 13 Energy Star & LEED Compliant SPF Roof System Roof System with Acrylic Coating, Aggregate & Cementitious Traffic Topping PART 1 GENERAL 1.01 Work Included A. Preparation
More informationTechnical Data Sheet NUKOTE SIL HS DESCRIPTION:
DESCRIPTION: Nukote SIL HS is a single-component silicone elastomer specifically designed as Cool Roof Tope/Base Coats. It is a pure elastomeric silicone coating system that provides superior weatherproofing,
More informationTOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets
TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications
More informationThermoplastic Single Ply & Multi-Ply Roofing Systems
Thermoplastic Single Ply & Multi-Ply Roofing Systems COMMERCIAL INDUSTRIAL INSTITUTIONAL RESIDENTIAL Specializing in Roof Solutions for over 25 years FlexRoofingSystems.com Thermoplastic Single Ply Roof
More information3,Rothwell Street, Timaru, South Canterbury. ; : Phone or
ECO-SEAL 100 3,Rothwell Street, Timaru, South Canterbury Email; ideaslab64@gmail.com : Phone +64 3 688 5508 or 0275 239888 Two Pack Flexible Self Priming high hysteresis waterproofing membrane designed
More informationHenry #1 CHOICE OF PROFESSIONALS
Henry #1 CHOICE OF PROFESSIONALS GUIDE SPECIFICATION HENRY SPECIFICATION H-MR EXISTING ROOF MONOLITHIC MAINTENANCE COOL ROOF REFLECTIVE GUIDE SPEC H-M R The enclosed guide specification, general requirements
More informationFireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets
FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com FireShield
More informationSOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY
SOLAR COATING SYSTEMS ACRYLIC ROOF RENOVATION 4.5 Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY NAME ADDRESS A. Furnish and install a seamless, waterproof spray applied elastomeric
More informationSILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL
SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL Part 1. 1.1 Description General Conditions A. Scope of Work Provide all materials, labor and equipment required for the installation
More informationACRYLIC-URETHANE ROOF COATING SYSTEMS SOPREMA
R NOVA PLUS ACRYLIC-URETHANE ROOF COATING SYSTEMS SOPREMA R Nova Plus is a waterborne, single-component roof coating comprised of a self-crosslinking modified acrylic-polyurethane dispersion. The polymer
More information"WE CAN AGUASEAL THAT" AGUASEAL WATERPROOFING SYSTEMS A G U A B A S E
"WE CAN AGUASEAL THAT" AGUASEAL WATERPROOFING SYSTEMS A G U A B A S E A G U A B A S E WHAT IS AGUABASE? AguaBase is utilized worldwide as a waterproofing system for below grade foundation walls, steel
More informationSection Fluid-Applied Roofing. Modified Bitumen Roof Preservation System Master Guide Specification
Section 07560 Fluid-Applied Roofing Modified Bitumen Roof Preservation System Master Guide Specification 1 PART 1 GENERAL 1.1 RELATED WORK SPECIFIED ELSEWHERE A. Rough Carpentry: Section 06100 B. Board-Stock
More informationDOWSIL ALLGUARD Silicone Elastomeric Coating
Technical Data Sheet Water-based silicone elastomer for waterproofing above-grade exterior masonry substrates Features & Benefits Provides long-term waterproofing protection Maintains water protection
More informationGuideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing
221 Brooke Street Media, PA 19063 610-566-7470 Fax 610-891-0834 Website www.acrymax.com e-mail info@acrymax.com This document is intended to provide guidelines for the proper specification and application
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WARRANTY ON CONCRETE SURFACE COATING
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WARRANTY ON CONCRETE SURFACE COATING OFS:BDB 1 of 5 APPR:JAB:CER:02-10-17 FHWA:APPR:02-28-17 a. Description. This work consists of furnishing
More informationCOOL BARRIER ROOF. High Solar Reflective Elastomeric Liquid Applied Roof Coating Water-Based for Big and Low Slope Roofs
High Solar Reflective Elastomeric Liquid Applied Roof Coating Water-Based for Big and Low Slope Roofs Energy Savings Thermal Comfort Weather Resistance Long Term Protection COOL BARRIER ROOF Cool Roof
More informationEVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281
EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281 EXTERIOR RESEARCH & DESIGN, LLC. 353 CHRISTIAN STREET OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Date of Issuance:
More informationA. Submit product data sheets and literature verifying physical properties of materials.
I. GENERAL ACRYPLY ROOFING SYSTEM Installation Guide Specification 07560 1-Ply All Acrylic System for EPDM Roofs - 10 Year Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A.
More informationA. Submit product data sheets and literature verifying fire ratings and physical properties of materials.
I. GENERAL ACRYSHIELD ROOF MANAGEMENT SYSTEM Installation Guide Specification For Preserving BUR & Mod Bit Roofs 07560 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide
More informationSILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER GRAVEL SURFACE BUR
SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER GRAVEL SURFACE BUR Part 1. 1.01 Description General Conditions A. Scope of Work Provide all materials, labor and equipment required for the installation
More informationDURA 500 LIQUID RUBBER THERMOPLASTIC ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.
Part 1 General Information SPECIFICATION GUIDELINE FOR DURA 500 LIQUID RUBBER THERMOPLASTIC ROOF COATING AS APPLIED TO METAL SLOPED ROOFING For the purpose of clarification in this document, the terms
More informationCopolymer BEFORE. Copolymer DURING. Copolymer AFTER. (800) TRI-CHEM 3
Roof Repair Copolymer BEFORE Copolymer DURING Copolymer AFTER www.tri-chem.com (800) 456-6255 TRI-CHEM 3 TECHNICAL DATA SHEET TRI-MEMBRANE DESCRIPTION Tri-Membrane is an asphalt impregnated cotton membrane
More informationHenry #1 CHOICE OF PROFESSIONALS
Henry #1 CHOICE OF PROFESSIONALS GUIDE SPECIFICATION HENRY SPECIFICATION H2-PE-MR 2-PLY EXISTING ROOF SLOPE #107 POLYESTER PLY SHEET MONOLITHIC SURFACING COOL ROOF REFLECTIVE COATING GUIDE SPEC H2-PE-M
More informationTEN YEAR SPECIFICATION FOR SEALGUARD VFI-991 FLUID APPLIED SILICONE MEMBRANE FOR REHABILITATION OF LAPPED METAL ROOFS
TEN YEAR SPECIFICATION FOR SEALGUARD VFI-991 FLUID APPLIED SILICONE MEMBRANE FOR REHABILITATION OF LAPPED METAL ROOFS 1 GENERAL: 1.01 General System Description A. Restoration Coating System is recommended
More informationGUIDE SPECIFICATION SECTION 07576
GUIDE SPECIFICATION SECTION 07576 TRAFFIC DECK MEMBRANE SYSTEM NOTE TO ARCHITECTS & ENGINEERS: The Oak Ridge traffic membrane system provides for applied high build, durable and waterproof membrane consisting
More informationA. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.
I. GENERAL ACRYSHIELD SPF ROOFING SYSTEM Installation Guide Specification SPF Vapor Retarder System 07500 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide labor, materials,
More informationTOPCOAT System Specifications Corrugated Transite Panels
TOPCOAT System Specifications Corrugated Transite Panels Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT System Specifications Corrugated Transite
More informationA. Submit product data sheets and literature verifying physical properties of materials.
I. GENERAL ACRYSHIELD ROOF MANAGEMENT SYSTEM Installation Guide Specification For Preserving EPDM Roofs 07500 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide labor,
More informationRecommended Application Procedures
Recommended Application Procedures Updated: September, 2016 Balanced Coating Properties StreetBond DuraShield Pavement Coating is an acrylic, waterborne coating specifically designed for application on
More informationSECTION SELF-ADHERING SHEET FLASHING
MANUFACTURER S GUIDE SPECIFICATIONS SECTION 076526 SELF-ADHERING SHEET FLASHING 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 604129 03.24.15 Carlisle, Flexphalt, Sure-Seal and CAV-GRIP
More informationPRODUCT INFORMATION. 1/ Version #4
PRODUCT DATA SHEET SARNAFIL G 410 SA (SELF ADHERED) ENERGYSMART ROOF MEMBRANE Sarnafil G 410 SA EnergySmart Roof is a PVC thermoplastic membrane with a factory applied pressure sensitive adhesive backing
More informationMagna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data
Magna Wall Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data s t u c c o D 9 Magna Wall Elastomeric Coatings (Non-Textured) product Overview Magna Wall Elastomeric Coatings are
More informationPol-E-Base Modified Bitumen Roof System
Pol-E-Base Modified Bitumen Roof System Specification Chemicals, Inc. produces the Pol-E-Base Built-up Roofing System as the ultimate in field applied reflective insulation roofing. It has the advantages
More informationFireShield Restoration Specifications - EPDM
FireShield Restoration Specifications - EPDM Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com FIRESHIELD Restoration Specifications EPDM PART 1 GENERAL
More informationSC-113 STRONGCOTE VEHICULAR GRADE TRAFFIC DECK MEMBRANE SYSTEM SECTION 07570
PART 1 - GENERAL 1.01 SECTION INCLUDES SC-113 STRONGCOTE VEHICULAR GRADE TRAFFIC DECK MEMBRANE SYSTEM SECTION 07570 A. SC-113, Heavy Duty Vehicular Grade Traffic Deck Membrane System with Migratory Corrosion
More informationSECTION (LIGHT TRAFFIC DECKS OVER CONCRETE) Updated February 18, 2011
SECTION 07560 (LIGHT TRAFFIC DECKS OVER CONCRETE) Updated February 18, 2011 PART 1 GENERAL 1.1 DESCRIPTION 1. Fluid applied flexible acrylic waterproofing system over concrete. This work shall include
More informationSECTION FLUID APPLIED ROOFING. (Commercial Standing Seam Metal Panels)
SECTION 07560 (Commercial Standing Seam Metal Panels) PART 1 DESCRIPTION 1.1 DESCRIPTION This specification is only intended for the application of the PremiumCoat system over commercial standing seam
More informationJ&L Building Materials, Inc. Commercial Roofing
J&L Building Materials, Inc. Commercial Roofing SBS & APP MODIFIED CERTAINTEED MODIFIED BITUMEN FLINTLASTIC GMS SBS MODIFIED BITUMEN ROLL ROOFING PRODUCTS 8 colors match to match Landmark shingles. SBS
More informationSection Fluid-Applied Roofing. EPDM Roof Preservation System Master Guide Specification
1 PART 1 GENERAL Section 07560 Fluid-Applied Roofing EPDM Roof Preservation System Master Guide Specification 1.1 RELATED WORK SPECIFIED ELSEWHERE A. Rough Carpentry: Section 06100 B. Board-Stock Roof
More informationRENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION
STUC-O-FLEX RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION 09 97 23 PART 1-GENERAL 1.00 SCOPE: Manufacturer's specifications containing the requirements necessary
More informationEnduris * silicone roof coating
Enduris * 3500 silicone roof coating Product Description GE Enduris 3500 silicone roof coating is a high performing protective barrier for a variety of architectural surfaces and roofing substrates. Upon
More informationHenry #1 CHOICE OF PROFESSIONALS
Henry #1 CHOICE OF PROFESSIONALS GUIDE SPECIFICATION HENRY SPECIFICATION H1-PC-GN 1-PLY EXISTING ROOF SLOPE HENRY 902 Perm anent Bond or 903 High Solids Adhesive HENRY 902 Perm anent Bond or 903 High Solids
More informationDIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant
Spec Component: SC-073-03/11 Sikadur Combiflex SG Part 1 - General DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section 07900 Joint Sealers Elastomeric and non-elastomeric sealant 1.01 Summary A. This
More informationRefer to Substrates & Surface Preparation.
SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Aliphatic Acrylic Polyurethane Thin film, high gloss finish with exceptional weathering performance
More informationTOPCOAT Restoration Specifications Structural Concrete
TOPCOAT Restoration Specifications Structural Concrete Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications Structural Concrete
More informationMAKE ROOFS LAST LONGER
MAKE ROOFS LAST LONGER Roof Coatings & Roof Repair Single-Ply Metal Asphalt HIGHEST PERFORMING SYSTEMS. LOWEST APPLIED COST. METAL ROOF RESTORATION Metal Restoration Quick Guide Acrylic Polyurethane High
More informationPermaroof 500 Liquid Membrane application onto:- Corrugated asbestos roofs
Permaroof 500 Liquid Membrane application onto:- Corrugated asbestos roofs Permaroof UK Ltd www.permaroof.co.uk sales@permaroof.co.uk Tel: 0800 161 3722 Substrate preparation for existing asbestos roof
More informationRoof Repair Sealants
Roof Repair Sealants H.E.R. Flash Grade Polyurethane Sealant Quicket Self-Leveling Sealant 2100 MS Adhesive Sealant Silyl-Modified Adhesive Sealant Permathane 7108 Polyurethane Sealant HIGHEST PERFORMING
More informationCentennial School District Section Material Specifications MATERIAL SPECIFICATIONS:
MODIFIED MEMBRANE BASE SHEET MATERIAL SPECIFICATIONS: Tear Strength 2 in/min ASTM D 5147 110 lbf. MD 110 lbf. XD Tensile Strength 2 in/min ASTM D 5147 100 lbf. MD 100 lbf. XD Elongation ASTM D 5147 2.5%.
More informationEPDM SINGLE-PLY SYSTEM SUMMARY
EPDM SINGLE-PLY SYSTEM SUMMARY This is a generic summary of EDGE s more detailed EPDM SINGLE-PLY SYSTEM SPECIFICATION. For warranty purposes, Approved Applicators are responsible for studying, understanding,
More informationWESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient GLAS-SHIELD FLUID APPLIED REINFORCED ROOF SYSTEM
PART 1 - GENERAL WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient GLAS-SHIELD FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SM-1P-14-3G-A RECOVER SMOOTH SURFACE / CAP SHEET 1 PLY POLYESTER
More informationElastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet
07 55 53 Elastomeric Protected Membrane Roofing 07 55 56 Fluid-Applied Protected Membrane Roofing Restoration Coating System (RCS) over Cap Sheet PART 1 - GENERAL 1.1 SUMMARY A. This specification covers
More informationEPDM ROOF RESTORATION
EPDM ROOF RESTORATION This guide specification governs the installation of thermoplastic rubber coatings for the repair and resurfacing of fully adhered and mechanically fastened EPDM membranes. The use
More informationSECTION A. American Society for Testing and Materials (ASTM):
hp.seal-krete.com 306 Gandy Rd., Auburndale, FL 33823-2723 800.323.7357 863.967.1535 fax:863-965.2326 Seal-Krete Vapor-Shell GUIDE SPECIFICATION SECTION 09725 PART 1 GENERAL 1.01 SECTION INCLUDES A. Provisions
More informationNutech Roof Coatings Nutech Paint Application Instructions & Guidelines Nutech Roof Coating Range of Products
Description NXT Seal Coat is a single component, solvent-borne, moisture-cured, fluid-applied silicone coating. NXT Seal Coat is a breathable membrane possessing superior weathering and water resistance
More informationLiquid-Applied Roof Solutions ACRYLIC & SILICONE COATINGS PRIMERS & ACCESSORIES
Liquid-Applied Roof Solutions ACRYLIC & SILICONE COATINGS PRIMERS & ACCESSORIES Water Based Acrylic Coatings 70 Premium Grade Elastomeric Roof Coating ASTM D6083 Type I compliant 4.75 Gallon / 50 Gallon
More informationA/D Firefilm III PRODUCT DATA SHEET
SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer A single package, water based intumescent coating designed for the fire protection of interior structural steel. A/D
More informationINSTALLATION GUIDE SPECIFICATION
INSTALLATION GUIDE SPECIFICATION FLUID-APPLIED WATERPROOFING (OVER EXISTING METAL ROOF DECK) PART 1 GENERAL 1.01 DESCRIPTION A. Scope Installation of a premium acrylic roof coating system to waterproof
More informationRefer to Substrates & Surface Preparation.
SELECTION & SPECIFICATION DATA Generic Type Description Features Aliphatic Acrylic Polyurethane High gloss finish with exceptional weathering performance characteristics. Used extensively in virtually
More informationAPPLICATION GUIDELINE
PROVEN ACRYLIC ROOFING SYSTEMdesigned to restore & protect metal roofs METAL To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins. PART 1 GENERAL 1.01 DESCRIPTION
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1221 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 07 00
More informationFluid Applied All Acrylic Coating System Guide Specification Tropical Roofing Products-TPO/PVC 4.0G911. Built On The Principles of Quality & Integrity
PART I GENERAL APPLICABLE PUBLICATIONS The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
More informationData Sheet Eco-Smart Membrane WS M1
Water-based Acrylic WS M1 Elastomeric Waterproofing Membrane is a durable, multi-use, extremely durable acrylic coating. At an ideal wet film thickness of 10-14 mils per coat (8-10 mils dry film finish
More informationDesmopol Application Guide for Corrugated Asbestos Roofs
Substrate Preparation Existing Roof Inspect existing Asbestos sheeting. Thoroughly clean the sheets making it free from contaminants of moss and lichen including any grease and dust. Small cracks and damaged
More informationBENEFITS & ADVANTAGES:
APPLICATION GUIDELINES WHITE REFLECTIVE The following KARNAK Roof Restoration System is intended to be applied over sound, dry, existing smooth built-up asphalt and smooth or granular modified bitumen
More informationKarnak 505 Elasto-Brite M Metal Roof Coating System
GUIDE SPECIFICATIONS SECTION: 07545 PART 1 GENERAL 1.0 Scope Of Work: A. Work Included: The contractor will provide all labor, materials, equipment,required to prepare and complete the installation of
More information900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable
900HA (US Version) Fast-cure, hand-applied liquid waterproofing membrane Product Description 900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable after
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3392 Reissued 06/2018 This report is subject to renewal 06/2019. DIVISION: 07 00
More informationHYPERDESMO Polyurethane liquid membrane for waterproofing & protection, easy application. alchimica.com. Page 1/5 DESCRIPTION
Page 1/5 Polyurethane liquid membrane for waterproofing & protection, easy application. DESCRIPTION is a simple and economic solution for waterproofing and protection. It is a one component, low viscosity,
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3392 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 07 00
More informationINLAND COATINGS CORPORATION SYSTEM SPECIFICATION FOR MODIFIED BITUMEN ROOFING
INLAND COATINGS CORPORATION SYSTEM SPECIFICATION FOR MODIFIED BITUMEN ROOFING IMB350M-6 July 2013 This specification provides a strong, flexible, synthetic rubber membrane that is resistant to water, corrosion
More informationWESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient GLAS-SHIELD FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient GLAS-SHIELD FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. GR-1P-18-3-** RECOVER GRAVEL SURFACE 1 PLY POLYESTER & GLASS FIBER ROVING REINFORCED
More informationRECOMMENDED DESIGN SPECIFICATION
RECOMMENDED DESIGN SPECIFICATION SILICONE COATED SPF ROOFING 1 General 1.1 Section Includes A. Silicone coated SPF roofing system, including substrate board, roof insulation boards, foam insulation materials,
More informationIB PVC Single-Ply 50. Technical Data Sheet
IB PVC Single-Ply 50 IB PVC Single-Ply 50 is a polyester scrim reinforced, compounded pvc resin based sheet with plasticizers, stabilizers, fi llers, pigments and other proprietary materials meeting ASTM
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3916 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 07 00
More information***********************************************************************************
AQUAFIN-2K/M Two-Component Cement-based Acrylic-based Waterproofing GUIDE AQUAFIN, Inc. SPECIFICATION PART 1 - GENERAL 1.1 SECTION INCLUDES SECTION 07 16 14 ACRYLIC MODIFIED (FLEXIBLE) CEMENTITIOUS WATERPROOFING
More informationPackaging: Packaged in 5 gal. pails and 55 gal. steel drums. 260 gal. totes are available as a special order.
1. PRODUCT NAME MA-SA Acrylic Color Coating 2. MANUFACTURER- Co Producer GVK IBES Co. Inc. Phone: 1-508-949-0939 Cell: 1-774-253-1776 Email: greggvk@gmail.com Website: 3. PRODUCT DESCRIPTION MA-SA Acrylic
More informationSTRONGCOTE SC-111 PEDESTRIAN GRADE TRAFFIC DECK COATING SYSTEM SECTION 07570
STRONGCOTE SC-111 PEDESTRIAN GRADE TRAFFIC DECK COATING SYSTEM SECTION 07570 PART 1 - GENERAL 1.01 SECTION INCLUDES A. SC-111, Pedestrian Grade Traffic Deck Membrane System with Migratory Corrosion Inhibitors
More informationCarboxane 950 Metallic
SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Fluorourethane Premium, ultra-durable ambient cured finish meeting performance requirements. 950
More informationDAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone
DAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone PRODUCT DESCRIPTION DAP ALEX FAST DRY ACRYLIC LATEX CAULK PLUS SILICONE is specifically formulated to meet the demanding needs of Professional Painters
More informationDIVISION 9 - FINISHES Section Coatings
Spec Component: SC-031-0907 Sikagard 62 DIVISION 9 - FINISHES Section 09900 Coatings Part 1 - General 1.01 Summary A. This specification describes the overlay of interior horizontal surfaces with an epoxy
More informationUltraPly TPO SA. Product Information. Description: Membrane Preparation: Method of Application: Item Description
Item Description.060" x 5' x 100' White.060" x 10' x 100' White.060" x 5' x 100' Tan.060" x 10' x 100' Tan.060" x 5' x 100' Gray.060" x 10' x 100' - Gray Item Number W56TSA3660 W56TSA3699 W56TSAT660 W56TSAT699
More informationBenefits of Cool Metal Roofs There are many benefits of owning a cool metal roof. Here are just a few to consider: What is A Metal Roof?
www.abolinco.com Cool Barrier Technology High solar reflective Cool Technology which noticeably combines the improvement of thermal comfort conditions with the reduction of energy consumption for cooling.
More informationINLAND COATINGS SYSTEM SPECIFICATION FOR MODIFIED BITUMEN ROOFING
IMB352 FEB 2018 INLAND COATINGS SYSTEM SPECIFICATION FOR MODIFIED BITUMEN ROOFING This specification provides a strong, flexible, synthetic rubber membrane that is resistant to water, corrosion and weather
More informationMANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More informationMANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More informationApplication guide: Existing BUR systems
Application guide: Existing BUR systems Before we begin. For over 30 years our Canadian family owned business has been a leading manufacturer of top quality construction materials. Our broad range of products
More informationGE SCM3500 High Solids Silicone Roof Coating
GE SCM3500 High Solids Silicone Roof Coating Installation Guide Specification for Restoration of Existing Metal Roofs (20 Year Warranty) Warranty PART 1 GENERAL 1.01 SUMMARY A. GE SCM3500, manufactured
More informationEDGEWATER, FLORIDA JUNE 14, 2010
SECTION 09 2422 - STO QUIK GOLD SOFFIT SYSTEM PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationRoofcoat Xtra. all- weather protection To Order FREEPHONE SEALS ROOFS 10 YEARS* SAVE s TOP QUALITY
www.roofcoatxtra.co.uk SAVE s WITH TOP QUALITY Supplies Sealing your roof just got... Easier, quicker, cheaper and better ROOFS all- weather protection To Order 0800 02 88 272 FREEPHONE JUST ONE COAT GIVES
More informationHenry #1 CHOICE OF PROFESSIONALS
Henry #1 CHOICE OF PROFESSIONALS GUIDE SPECIFICATION HENRY SPECIFICATION H2-PE-GN 2-PLY EXISTING ROOF SLOPE HENRY 107 Asphalt Em ulsion HENRY 107 Asphalt Em ulsion POLYESTER PLY SHEET GRANULES GUIDE SPEC
More informationBidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.
McKee and Associates Architecture and Interior Design Addendum No. ONE Date: 11.26.18 Project: Re-Roofing Various Buildings at Westdale Apartments for the Luverne Housing Authority Luverne, Alabama McKee
More informationFoamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation
07 21 19 Foamed-in-place insulation 07 21 29 Sprayed insulation Spray Foam Insulation for Residential Building Envelope Insulation PART 1 - GENERAL 1.1 SUMMARY This document discusses the application of
More informationSUBMITTALS Descriptive literature: Submit manufacturer's application instructions and technical data sheets or catalog cuts on materials.
PART I GENERAL APPLICABLE PUBLICATIONS The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
More informationSECTION FLUID APPLIED ROOFING
SECTION 07560 FLUID APPLIED ROOFING PART 1 GENERAL 1.1 DESCRIPTION OF EXISTING SUBSTRATES This specification is intended to outline the requirements for application of the Aqua- Fast system, in conjunction
More informationReducing Over-heating of Buildings by use of White Reflective Roof Coatings (WRRCs)
Reducing Over-heating of Buildings by use of White Reflective Roof Coatings (WRRCs) The Middle East Conference on Sustainable Building Materials, Dubai, Feb 23rd 2011 Brown Joseph The Dow Chemical Company
More information