Thomas Connors Executive Director, Construction Site Safety

Size: px
Start display at page:

Download "Thomas Connors Executive Director, Construction Site Safety"

Transcription

1 Thomas Connors Executive Director, Construction Site Safety

2 Agenda Site Safety Plans Site Safety Requirements BEST Squad Inspections 2

3

4 Site Safety Plans 4

5 Site Safety Logistics Plan Material/ Personal Hoist Sidewalk Shed Protection Siamese Pedestrian Connection Traffic Radius Craneof Location Crane Flagperson(s) Worker Traffic Construction Fence FDNY Lockbox Roof Protection 5

6

7 Site Safety Manager/Coordinator Requirements: Site Safety Coordinator Required on All Construction and Demolition Permits for Buildings Stories Site Safety Manager Required on All Construction and Demolition Permits for Buildings 15 Stories and Above 7

8 Site Safety Manager/Coordinator Must Confirm Compliance Site Safety Requirements on Buildings and Demolitions Standpipe Inspections Proper Safety Netting Adequate Sidewalk Protection Suitable Housekeeping Scaffold Maintenance Proper Material/Equipment Handling Construction Safety Standards 8

9 Proper Safety Netting 9

10 Adequate Sidewalk Protection 10

11 Poor Housekeeping 11

12 Shed & Scaffold Maintenance 12

13 Proper Material Handling 13

14 Demolitions 14

15 Site Safety Manager/Coordinator 1. Maintenance of Site Safety Log 2. Maintenance of Permit Log Jobsite Equipment Documentation Both logs must be on-site and available 15

16 Site Safety Manager/Coordinator Standpipe Inspection Weekly Tracing of the Entire System Daily Inspection of Valves Below Construction Floor Daily Inspection Siamese Connection 16

17 Site Safety Manager/Coordinator Inspections: Verify Standpipe Operability Connection to Water Source (if applicable) and Siamese Connection Siamese Connections Unobstructed, Marked with Red Light and Sign No Breaches in System 17

18 Site Safety Manager/Coordinator Inspections: Maintenance of Site Verify Areas Used by Public are Unobstructed Openings/Holes in floors are Covered & Secured 18

19 Site Safety Manager/Coordinator Protection of Adjoining Properties 19

20 Site Safety Manager/Coordinator Inspections: Housekeeping Floors and Stairs are Unobstructed Tools and Equipment Not in Use Away from Edges and Openings Sidewalk Shed Roof and Street are Free of Debris Sufficient Storage and Trash Receptacles are Provided Full Containers are Covered and Secured 20

21 Site Safety Manager/Coordinator Inspections: Removal and Storage of Material Stored Material is At Least 10 Feet From Perimeter of Building Combustible Materials are Removed Daily Insure the Safe 21 Removal of Debris

22 Site Safety Manager/Coordinator Inspections: Protection Of The Public Installation of Sidewalk Sheds: Current Permits Proper Illumination Temporary Footbridges and Walkways Warning Signs and Lights Flagperson where Required 22

23 Hoisting Systems Exterior Hoists Personnel Material Combined Temporary Certificates are valid for 90 days. 23

24 Hoisting Systems Engineered Monorail Hoisting Systems: DOB Permit Required Controlled inspection upon installation 24

25 Site Safety Manager/Coordinator Inspections: Material Handling and Hoisting Cranes & Derricks Verify Certificates of Approval and Operation are Available at Site Licenses of Crane Operators are Available Jumping Operations are in Accordance with Approved Schedule Submitted by P.E. 25

26 Future Fire Suppression System Safety Requirements The following requirements are currently being drafted: Uniform color coding Alarm system for new buildings and demolitions Licensed Plumber or Fire Suppression Contractor: Required to pressure test system Permit requirement for cut and cap system during full demolition 26

27 New Safety Legislation Local Law 06/09 Authorizes Department to Assign Safety Compliance Officer to Accident Prone Construction Sites Passed By Council on Thursday, January 28, 2009 Signed by Mayor on February 10,

28 28

29 Concrete Safety Manager (CSM) New Requirements: Buildings where at least 2,000 cubic yards are to be poured Required During all Forming, Pouring and Stripping Operations A Separate Log Book Must Register by: July 1,

30 Concrete Form Failure Concrete Safety Manager 30

31

32 Building Enforcement Safety Team: Inspections Exterior: Fences, Sheds, Barriers and Walkways Hoisting Operations, Material Deliveries and Flagperson Siamese Connection Free of Obstructions 32

33 Building Enforcement Safety Team: Inspections Exterior: Vertical and Horizontal Netting Curtain Wall and/or Glass Installation 33

34 Building Enforcement Safety Team: Inspections Interior: Standpipes & Elevator in Readiness Stairs, Handrails & Ladders Housekeeping & Material Storage including Flammable Gases Floor Openings and Toe Boards Personal Fall Arrest Systems Forming and Stripping Operations Re-Shores Smoking 34

35 $2,400 Fine 35

36 Building Enforcement Safety Team: Inspections Administrative: Site Safety Manager Review of Log Books Review of Buildings and FDNY Permits 36

37 Building Enforcement Safety Team: Inspections Excavation Team Cranes & Derricks Scaffold Safety Team Low Rise 37

38 Low Rise 38

39 Top 5 Violations 1. Missing Site Safety Manager 2. Failure to Institute Safety Measures 3. Inadequate Standpipe/Siamese Connection 4. Failure to Safeguard Persons & Property 5. Failure to Maintain Elevator in Readiness 39

40 Stop Work Order Program Improved Coordination Enhanced Communication 40

41 Over night Work not permitted After-Hours Work Variance Permit: Sidewalk Shed Lighting Elevator in Readiness Watchperson New York City Fire Code Siamese Connection Vehicular Barricades No Smoking Site Safety Manager 41

42 Building Enforcement Safety Team: Inspections In Development: Standardize Inspection Practices Laptop/Handheld Devices On-site Access: Buildings Website Building Code Respondent Information 42

43 Working For Buildings BEST Squad Chief Needed 1 Centre St., 23rd Floor, New York, N.Y. 43

Buildings Department Safety and Inspection Requirements

Buildings Department Safety and Inspection Requirements Buildings Department Safety and Inspection Requirements Presented by Andrey Vishev, Chief of NYCDOB BEST Squad at the 28th Annual North-East Regional Tri-Sectional (NY-NJ-PA) Industrial Hygiene Conference

More information

NEW YORK CITY DEPARTMENT OF BUILDINGS. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

NEW YORK CITY DEPARTMENT OF BUILDINGS. Notice of Public Hearing and Opportunity to Comment on Proposed Rule NEW YORK CITY DEPARTMENT OF BUILDINGS Notice of Public Hearing and Opportunity to Comment on Proposed Rule What are we proposing? The Department of Buildings (DOB) is proposing amendments to Section 3310-01

More information

SAFEGUARDS DURING CONSTRUCTION

SAFEGUARDS DURING CONSTRUCTION CHAPTER 14 SAFEGUARDS DURING CONSTRUCTION SECTION 1401 GENERAL [B] 1401.1 Scope. The provisions of this chapter shall govern safety during construction that is under the jurisdiction of this code and the

More information

5/15/2013. Approved Course Title 2010 Existing Building Code Chapters Florida Building Code, Existing Building. Chapters

5/15/2013. Approved Course Title 2010 Existing Building Code Chapters Florida Building Code, Existing Building. Chapters 2010 Florida Building Code, Existing Building A Code for Existing Buildings Approved Course Title 2010 Existing Building Code Chapters 10-14 Chapters 10-14 Module Objectives Chapter 1 Administration Chapter

More information

Jobsite Specifications The A standard provides jobsite specifications for each of the following hazards:

Jobsite Specifications The A standard provides jobsite specifications for each of the following hazards: Overview of American National Standard A10.34-2001 Protection of the Public on or Adjacent to Construction Sites American National Standard for Construction and Demolition Operations The A10.34-2001 standard

More information

5/9/ Florida Building Code, Existing Building. Chapters Approved Course Title 2010 Existing Building Code Chapters

5/9/ Florida Building Code, Existing Building. Chapters Approved Course Title 2010 Existing Building Code Chapters 2010 Florida Building Code, Existing Building A Code for Existing Buildings This slide is being narrated. If you do not hear a voice, check your speakers or return to the Main Menu and click on System

More information

2014Construction Code: Chapter 33 Key Revisions

2014Construction Code: Chapter 33 Key Revisions Robert D Alessio Department of Buildings Senior Executive Director Engineering and Safety Operations New York University-Kimmel Center Tuesday, March 24, 2015 2014Construction Code: Chapter 33 Key Revision

More information

Property and Public Protection Plan

Property and Public Protection Plan Property and Public Protection Plan OTTO CONSTRUCTION PROPERTY AND PUBLIC PROTECTION PLAN Otto Construction s pre-planning of construction activities includes procedures to protect the general public and

More information

THE REAL ESTATE BOARD OF NEW YORK CONSTRUCTION SAFETY

THE REAL ESTATE BOARD OF NEW YORK CONSTRUCTION SAFETY THE REAL ESTATE BOARD OF NEW YORK CONSTRUCTION SAFETY CONSTRUCTION SAFETY 1 ANALYSIS OF CONSTRUCTION ACCIDENTS (2010 2015) CONSTRUCTION SAFETY 2 CONSTRUCTION RELATED ACCIDENT REPORTS In 2008, DOB enacted

More information

Cherokee Nation Entertainment Casino Ramona, Oklahoma. WORK PACKAGE: Existing Casino Demolition and Dismantling 8/7/12

Cherokee Nation Entertainment Casino Ramona, Oklahoma. WORK PACKAGE: Existing Casino Demolition and Dismantling 8/7/12 SCOPE SUMMARY: DIVISION: 0 - LEGAL DOCUMENTS Complete; DIVISION: 1 - GENERAL REQUIREMENTS As Applicable; SECTION: - ATTACHED SKETCH Complete; Geotechnical Engineering Report as prepared by Building and

More information

NEW YORK CITY DEPARTMENT OF BUILDINGS. Notice of Public Hearing and Opportunity to Comment on Proposed Rules

NEW YORK CITY DEPARTMENT OF BUILDINGS. Notice of Public Hearing and Opportunity to Comment on Proposed Rules NEW YORK CITY DEPARTMENT OF BUILDINGS Notice of Public Hearing and Opportunity to Comment on Proposed Rules What are we proposing? The Department of Buildings (DOB) is proposing to amend the rules regarding

More information

Fall Protection Safety Program and Training Materials

Fall Protection Safety Program and Training Materials Prepared by Built Insurance Brokerage Fall Protection Safety Program and Training Materials Fall Protection Program... 1 Employee Fall Protection Flyer... 7 Fall Hazard Survey... 8 Requirements for Industrial

More information

SECTION 23 DEMOLITION

SECTION 23 DEMOLITION SECTION 23 DEMOLITION 23.A GENERAL 23.A.01 Demolition activities shall be performed in accordance with ANSI Standard A10.6, Safety Requirements for Demolition. Surveys and planning shall meet the following:

More information

Section Subparts T. Cleveland State University Work Zone Safety and Efficiency Transportation Center. Demolition

Section Subparts T. Cleveland State University Work Zone Safety and Efficiency Transportation Center. Demolition Demolition 1926.252(a) Whenever materials are dropped more than 20 feet to any point lying outside the exterior walls of the building, an enclosed chute of wood, or equivalent material, shall be used.

More information

SECTION TEMPORARY FACILITIES AND CONTROLS

SECTION TEMPORARY FACILITIES AND CONTROLS SECTION 015000 TEMPORARY FACILITIES AND CONTROLS PART 1 - GENERAL 1.1 GENERAL A. Each Contractor shall be responsible for arranging for and providing construction facilities and temporary controls as required

More information

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date BUILDING AND SAFETY Tenant Improvement Checklist Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date APPLICATION The following items will be required at the permit counter before

More information

SAMPLE PAGES. Construction Safety and Health Program. [Company name]

SAMPLE PAGES. Construction Safety and Health Program. [Company name] The safety and health of our employees is our top priority. Everyone goes home safe and healthy every day. Construction Safety and Health Program [Company name] [Date Authorized] [Version} 0 Contents Mission

More information

SAN DIEGO STATE UNIVERSITY PACIFIC CORNERSTONE ARCHITECTS TENOCHCA HALL PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

SAN DIEGO STATE UNIVERSITY PACIFIC CORNERSTONE ARCHITECTS TENOCHCA HALL PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION SECTION 02 41 14 SELECTIVE BUILDING DEMOLITION PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Procedures for systematic removal of site improvements or portions of exterior and interior of buildings

More information

DEMOLITION BY USE OF EXPLOSIVES

DEMOLITION BY USE OF EXPLOSIVES INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.3303.9 Effective: 7-14-95 DOCUMENT NO. P/BC 2002-020 Revised: 11-17-00 Previously Issued As: MGD #105 DEMOLITION BY USE OF EXPLOSIVES

More information

EM385 Construction Safety and Health Certification Course Section 23 Demolition

EM385 Construction Safety and Health Certification Course Section 23 Demolition EM385 Construction Safety and Health Certification Course Section 23 Demolition EM 385 SAFETY AND HEALTH CERTIFICATION COURSE - SECTION 23 Edited by: Steven Geigle, M.A., CET, CSHM Copyright 2013 Geigle

More information

BARRY S CORNER. Draft Construction Management Plan

BARRY S CORNER. Draft Construction Management Plan 1. Introduction Project description BARRY S CORNER Draft Construction Management Plan 11-21-2013 Prepared for: Boston Transportation Department Project Proponent: Samuels & Associates Construction Manager

More information

FIRE SAFETY DURING CONSTRUCTION, ALTERATION, DEMOLITION & ABATEMENT INSPECTIONAL GUIDE 2008

FIRE SAFETY DURING CONSTRUCTION, ALTERATION, DEMOLITION & ABATEMENT INSPECTIONAL GUIDE 2008 BUILDING INSPECTION SAFETY PROGRAM MANUAL CHAPTER 3, ADDENDUM 2, INSPECTIONAL GUIDE May 10, 2010 FIRE SAFETY DURING CONSTRUCTION, ALTERATION, DEMOLITION & ABATEMENT INSPECTIONAL GUIDE 2008 This inspectional

More information

Demolition Safety!!!!

Demolition Safety!!!! Sample Written Program For Your Company For Demolition Safety Provided By: P.O. Box 2136 Slidell, LA 70458 Phone: 985-781-1444 Fax: 985-718-4957 Email: info@se-safety.com Demolition Safety Program Purpose

More information

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) , BUILDING PERMIT REQUIREMENTS FOR BASEMENT REMODELING 1. Provide two copies of a detailed floor plan and elevation drawing, see sample drawings on page 9 and 10. Include materials, sizes, supports, heating,

More information

Jobsite Layout Considerations

Jobsite Layout Considerations 1 Jobsite Layout Considerations The controlling contractor must consider many factors when laying out a site to support construction operations Site and building size and Equipment requirements configuration

More information

General Building Information

General Building Information Software Module s Description Page 1 General Building Information BUILDING AREA AND HEIGHT - This module designed to determine the height and area of buildings on the basis of occupancy group classification

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 024116 - STRUCTURE DEMOLITION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

MMM MASONRY, INC. Employee Safety Guidelines

MMM MASONRY, INC. Employee Safety Guidelines MMM MASONRY, INC. Employee Safety Guidelines This manual represents common hazards associated with masonry construction and is no way intended to replace the OSHA 29CFR 1926 Safety Standards. It is the

More information

Savard Labor & Marine Staffing, Inc. Fall Prevention Program Rev3/14

Savard Labor & Marine Staffing, Inc. Fall Prevention Program Rev3/14 Fall Prevention Program Purpose Slips, trips, and falls constitute a significant amount of accidents. They cause 15% of all accidental deaths, and are second only to motor vehicles as a cause of fatalities.

More information

Are designed to provide a safe working environment, and Govern use of fall protection procedures and equipment.

Are designed to provide a safe working environment, and Govern use of fall protection procedures and equipment. Fall Protection Plan for Construction OSHA currently regulates fall protection for construction under Part 1926, Subpart M. The standards for regulating fall protection systems and procedures are intended

More information

Able Electric. Aerial/Boom Lifts Workers in aerial lift are not tied off to boom or basket ( ) 3 Category Total 3

Able Electric. Aerial/Boom Lifts Workers in aerial lift are not tied off to boom or basket ( ) 3 Category Total 3 Able Electric Responsible Party: Able Electric Date Range: /24/205 - /24/206 Aerial/Boom Lifts Workers in aerial lift are not tied off to boom or basket (926.453) 3 Category Total 3 Aisles/Walkways Not

More information

ENGINEERING DIVISION CONCURRENT PLAN CHECK PROGRAM

ENGINEERING DIVISION CONCURRENT PLAN CHECK PROGRAM ENGINEERING DIVISION CONCURRENT PLAN CHECK PROGRAM Each applicant needs to thoroughly review the conditions of development issued by the Planning Division in the format of a Resolution approving your project

More information

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS New Construction, Addition, or Alteration All plans submitted must be prepared, sealed, and signed by a Registered Nebraska Design Professional

More information

Workplaces must be kept clean, orderly, and sanitary. Workroom floors must be maintained as clean and dry as possible.

Workplaces must be kept clean, orderly, and sanitary. Workroom floors must be maintained as clean and dry as possible. Section C.19 University of South Carolina Safety Program Guide WALKING AND WORKING SURFACES Introduction Occupational Safety and Health Administration (OSHA) CFR 1910 Subpart D Walking and Working Surfaces

More information

ATTACHMENT A. Bid # 6793

ATTACHMENT A. Bid # 6793 ATTACHMENT A SCOPE OF WORK TECHNICAL SPECIFICATIONS AND CONTRACT DRAWINGS STORAGE SHED INSTALLATION AT THE SAN JOAQUIN COUNTY HOUSEHOLD HAZARDOUS WASTE FACILITY Bid # 6793 Department of Public Works Solid

More information

MUNICIPALITY PERMIT Issued by the City of Holyoke 63 Canal Street, Holyoke, MA Phone (413) FAX (413)

MUNICIPALITY PERMIT Issued by the City of Holyoke 63 Canal Street, Holyoke, MA Phone (413) FAX (413) MUNICIPALITY PERMIT Issued by the City of Holyoke 63 Canal Street, Holyoke, MA 01040 Phone (413) 322-5645 FAX (413) 539-6807 DPW OFFICIAL USE ONLY Permit Number Date Issued Expiration Date (If Applicable)

More information

APPLICATION FOR PORCH / DECK PERMIT

APPLICATION FOR PORCH / DECK PERMIT Department of Neighborhood Services and Inspections 625 52nd Street, Room 100, Kenosha, WI 53140 Phone: 262.653.4263, Fax: 262.653.4254 APPLICATION FOR PORCH / DECK PERMIT Permit Fee: $60.00, Zoning Plan

More information

Fall Protection Plan for Construction

Fall Protection Plan for Construction Safety & Health Program 10627 Midwest Industrial Boulevard, St. Louis, MO Phone: 314-785-6425 Fax: 314-785-6426 Fall Protection Plan for Construction OSHA currently regulates fall protection for construction

More information

TRENCHING AND EXCAVATION

TRENCHING AND EXCAVATION TRENCHING AND EXCAVATION The following guide is an aid intended for students who have completed the ClickSafety training course or module associated with Trenching and Excavation. This guide is a resource

More information

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested. Purpose 355 West Queens Road Single Family New Construction Required Inspection Stages Master Requirement GEN 110 Building Department: 604-990-2480, building@dnv.org, fax: 604-984-9683 The following procedure

More information

ESCALATORS & MOVING WALKS

ESCALATORS & MOVING WALKS 1/86 Forsyth Street, O Connor WA 6163 Office +61 8 9331 1004 Emergency +61 8 9324 4313 ESCALATORS & MOVING WALKS BUILDER S GUIDE Commercial Passenger Lifts Domestic Passenger Lifts Lift Interiors Lift

More information

Richmond Hill Primary Renovation SECTION SELECTIVE DEMOLITION

Richmond Hill Primary Renovation SECTION SELECTIVE DEMOLITION SECTION 024119 SELECTIVE DEMOLITION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

August 11, Bill Grant President/Owner Best Company 1234 Main St Anywhere, USA Construction Safety Survey Omaha, NE.

August 11, Bill Grant President/Owner Best Company 1234 Main St Anywhere, USA Construction Safety Survey Omaha, NE. August 11, 2018 Bill Grant President/Owner Best Company 1234 Main St Anywhere, USA 12345 Re: Construction Safety Survey Omaha, NE Bill, This report is in follow-up to the safety survey completed on July

More information

I. Introduction/Welcome to MAPP

I. Introduction/Welcome to MAPP I. Introduction/Welcome to MAPP II. Company Policy HSE POLICY It is the commitment of MAPP to perform ALL work in the safest manner possible, while maintaining the highest level of construction practices.

More information

Subcontractor Project Management Plan

Subcontractor Project Management Plan Subcontractor Project Management Plan FOR LAYTON PROJECT: COMPANY: CONTACT NAME: ACTIVITY: Signed Date Written by: Reviewed by: Accepted by: Issue Date Description of Revisions Change Introduced by Change

More information

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS Section 201 General Definitions... 15

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS Section 201 General Definitions... 15 CHAPTER 1 ADMINISTRATION............... 1 101 Title, Purpose and Scope..................... 1 102 Unsafe Buildings, Structures or Premises....... 1 103 Violations and Penalties..................... 2 104

More information

Iron Ore Company of Canada Health, Safety & Environment

Iron Ore Company of Canada Health, Safety & Environment Barricading 1 PURPOSE To protect personnel by preventing or controlling access to hazards in work areas by the installation and maintenance of barricades, demarcation and restricting access. This work

More information

SECTION TRAFFIC CONTROL. A. The following is a list of standards which may be referenced in this section:

SECTION TRAFFIC CONTROL. A. The following is a list of standards which may be referenced in this section: SECTION 01 55 26 TRAFFIC CONTROL PART 1 GENERAL 1.01 SECTION INCLUDES A. Section covers requirements for traffic control during construction of the PROJECT. 1.02 REFERENCES A. The following is a list of

More information

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3% CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE EXAM ID: I6 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 3 % 0101. Project Administration 3% Verify that plans,

More information

The Hong Kong Polytechnic University Facilities Management Office

The Hong Kong Polytechnic University Facilities Management Office The Hong Kong Polytechnic University Facilities Management Office Safety Precautions and Requirements The Contractor shall ensure as a priority in all activities connected with the Works, the safety and

More information

Roadway Surfaces and Traffic Control Elements

Roadway Surfaces and Traffic Control Elements Roadway Surfaces and Traffic Control Elements Lines of Business: General Liability, Public Officials Liability www.tridentinsurance.net Risk Control Strategy/Key Issues: To establish and document a program

More information

ROAD CUT PERMIT APPLICATION & INSTRUCTIONS

ROAD CUT PERMIT APPLICATION & INSTRUCTIONS Jeremy Robinson Commissioner Ann Fordock Martin E. Davis, L.S. DEPARTMENT OF PUBLIC WORKS Ben Walsh, Mayor ROAD CUT PERMIT APPLICATION & INSTRUCTIONS REQUIRED FOR: Construction in (cutting into) a city

More information

SECTION CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS

SECTION CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS PART 1 GENERAL 1.1 DESCRIPTION A. Temporary Utilities: Electricity, lighting, heating, cooling, ventilation, water, and sanitary facilities. B. Temporary Controls: Barriers, fencing, erosion control, exterior

More information

Your Company Name. Hospital Phone: (318) Do cell phones work at the site? Yes No If no, location of the nearest landline:

Your Company Name. Hospital Phone: (318) Do cell phones work at the site? Yes No If no, location of the nearest landline: Your Company Name JOB HAZARD ANALYSIS (JHA) FORM (No elevated work 6 feet or more AGL) Complete daily before beginning work and review when work is complete. A copy of a site evaluation report shall remain

More information

Excavation Safety Program

Excavation Safety Program Excavation Safety Program Excavation, Trenching & Shoring Safety I. Purpose The purpose of this policy is to establish safe operating procedures for any earthwork or underground work that is done on a

More information

CONSULTING OFFICE OF MORRIS S. FARKAS PROFESSIONAL SAFETY ENGINEER

CONSULTING OFFICE OF MORRIS S. FARKAS PROFESSIONAL SAFETY ENGINEER CONSULTING OFFICE OF MORRIS S. FARKAS PROFESSIONAL SAFETY ENGINEER EDUCATION 3835 East Thousand Oaks Boulevard, #365 Westlake Village, California 91362 Telephone: (805) 494-0444 Facsimile: (805) 494-0441

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE CONSTRUCTION SAFETY STANDARDS PART 20. DEMOLITION

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE CONSTRUCTION SAFETY STANDARDS PART 20. DEMOLITION DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE CONSTRUCTION SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections

More information

Town of Falmouth FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage COSTS FOR SUBSTANTIAL IMPROVEMENTS / REPAIR OF SUBSTANTIAL DAMAGE:

Town of Falmouth FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage COSTS FOR SUBSTANTIAL IMPROVEMENTS / REPAIR OF SUBSTANTIAL DAMAGE: S FOR SUBSTANTIAL IMPROVEMENTS / REPAIR OF SUBSTANTIAL DAMAGE: Included Costs: Items that must be included in the costs of improvement or costs to repair are those that are directly associated with the

More information

ADDENDUM NO Refer to Specifications Section Alternates. Clarifications to alternate descriptions are as follows:

ADDENDUM NO Refer to Specifications Section Alternates. Clarifications to alternate descriptions are as follows: ADDENDUM NO. 1 TO THE DRAWINGS AND SPECIFICATIONS FOR THE New Dishman-McGinnis Elementary School Bowling Green Independent Schools Bowling Green, Kentucky BG 12-256 RTA 1209 March 11, 2013 To All Plan

More information

Construction Look Ahead February 2018

Construction Look Ahead February 2018 To our 9 th and Colorado redevelopment neighbors: Construction Look Ahead February 2018 Block 7South Exterior Bridge walkway between Block 7 South building and the existing Parking Garage the installation

More information

WORKING AT ELEVATED PLACES Working on Roofs

WORKING AT ELEVATED PLACES Working on Roofs WORKING AT ELEVATED PLACES Working on Roofs University workers who carry out roof work are exposed to a potential risk of falling. Falls can occur over an unprotected edge on a roof, through a fragile

More information

MVDC F041 Safety Inspection Checklist

MVDC F041 Safety Inspection Checklist MVDC F041 Safety Inspection Checklist JOB TITLE: DEPARTMENT: JOB NO.: DATE: LEGEND 1 Satisfactory 2 Requires Improvement 3 Non Existent 4 Not Applicable EMERGENCY PREPAREDNESS Emergency procedure is posted

More information

CONSTRUCTION SAFETY GUIDE

CONSTRUCTION SAFETY GUIDE California Institute of Technology CONSTRUCTION SAFETY GUIDE Caltech Environment, Health, and Safety Office 1200 E. California Blvd., M/C 25-6 Pasadena, CA 91125 Phone: 626.395.6727 Fax: 626.577.6028 Email:

More information

Current as of 11/10/08 1 of 5

Current as of 11/10/08 1 of 5 BEST PRACTICES STANDARDS FOR SCHOOLS UNDER CONSTRUCTION OR BEING PLANNED FOR CONSTRUCTION I. Site Layout A. School buildings shall be provided with a securable perimeter. A securable perimeter means that

More information

TYPICAL APARTMENT FLOOR PLAN

TYPICAL APARTMENT FLOOR PLAN PHOTO #7 PHOTO #8 EAST 8TH STREET (60' WIDE STREET) P L P L PHOTO #4 P L P L A B C D E F G H I #21 ASTOR PLACE 11 STORY BUILDING HEIGHT = 130' (11 STORIES) STAIR #3 BROADWAY (100' WIDE STREET) L STAIR

More information

THE CONSTRUCTION SUPERVISOR

THE CONSTRUCTION SUPERVISOR City of Aurora Building Inspections 15151 E Alameda Pkwy Aurora, CO 80012 (303) 739-7420 THE CONSTRUCTION SUPERVISOR When a building permit has been issued for any construction within the City, the Supervisor

More information

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1% CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE EXAM ID: I1 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 6% 0101. Project Administration 1% Verify that

More information

WORKING AT HEIGHT PROCEDURE

WORKING AT HEIGHT PROCEDURE Page 1 of 8 AL-Yamama Engineering Company HSSE Department (s) WORKING AT HEIGHT PROCEDURE Page 1 of 8 Page 2 of 8 Introduction Work at height is any work activity that is performed where the work is to

More information

WHITMAN COLLEGE TRENCHING AND SHORING PLAN

WHITMAN COLLEGE TRENCHING AND SHORING PLAN Purpose: WHITMAN COLLEGE TRENCHING AND SHORING PLAN This is a statement of official college policy to establish the process for compliance with safety standards as stated in the Washington State Administrative

More information

FRAMING INSPECTION GENERAL

FRAMING INSPECTION GENERAL FRAMING INSPECTION GENERAL 20 FRAMING INSPECTION GENERAL Tips Check habitable rooms for minimum light, ventilation and sanitation requirements. Check that stair framing meets headroom, width, and rise

More information

Permit Requirements: Building Codes: The City of Clanton has adopted the following codes which are enforced by the Building Department:

Permit Requirements: Building Codes: The City of Clanton has adopted the following codes which are enforced by the Building Department: Permit Requirements: Any owner, authorized agent, or contractor who desires to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install,

More information

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard. City of Gibraltar Pre-Sale Inspection Report Checklist FLATWORK: Repair or replace section of driveway, approach, or sidewalk that are a trip hazard. EXTERIOR PROPERTY: Fences/Sheds/Retaining walls: Repair,

More information

Installing metal decking, curtain walls, window walls, siding systems, miscellaneous metals, ornamental iron, and similar materials; and

Installing metal decking, curtain walls, window walls, siding systems, miscellaneous metals, ornamental iron, and similar materials; and Steel Erection Plan for Construction Purpose Company Name must meet the requirements of OSHA's Steel Erection standard (29 CFR 1926, Subpart R). This Steel Erection Plan for Construction is our company's

More information

Water service and distribution. Temporary electric power and light. Telephone service.

Water service and distribution. Temporary electric power and light. Telephone service. SECTION 01500 TEMPORARY FACILITIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division-1 Specification

More information

Phoenix Building Construction Code Updated Amendments to the Administrative Provisions

Phoenix Building Construction Code Updated Amendments to the Administrative Provisions Phoenix Building Construction Code Updated Amendments to the Administrative Provisions CHAPTER 1 ADMINISTRATION Section 101.2 Change to read as shown: 101.2 Scope. The provisions of this Code shall apply

More information

Continuing Certificate of Occupancy Pre-Inspection Checklist

Continuing Certificate of Occupancy Pre-Inspection Checklist Pre-Inspection Checklist INTRODUCTION: This pre-inspection checklist has been produced to assist you in preparing for a Continuing Certificate of Occupancy (CCO) inspection. The inspection criteria and

More information

Protective Barriers, Warning Signs and Tags

Protective Barriers, Warning Signs and Tags Protective Barriers, Warning Signs and Tags Short description This procedure outlines the guidance for the use of protective barriers, warning signs and tags on Centennial project sites. Contact person

More information

SITE ACCESSIBILITY AND PARKING

SITE ACCESSIBILITY AND PARKING SITE ACCESSIBILITY AND PARKING The purpose of this handout is to clarify the requirements of site accessibility under the 2013 California Building Codes, Specifically, Section 11B. Each lot or parking

More information

CITY OF DANA POINT SITE ACCESSIBILITY AND PARKING B103 SITE INTRODUCTION

CITY OF DANA POINT SITE ACCESSIBILITY AND PARKING B103 SITE INTRODUCTION INTRODUCTION CITY OF DANA POINT COMMUNITY DEVELOPMENT, BUILDING AND SAFETY 33282 Golden Lantern, Suite 209 Dana Point, CA 92629 949 248-3594 www.danapoint.org SITE ACCESSIBILITY AND PARKING B103 SITE 2013

More information

SCAFFOLDS Revision No: 3

SCAFFOLDS Revision No: 3 PAGE 1 OF 6 1.0 PURPOSE/ SCOPE To communicate the safety requirements for the erection, inspection and safe use of scaffolds. Compliance with these requirements will assure employee safety while working

More information

Chapter WAC Construction Work

Chapter WAC Construction Work Chapter 296-155 WAC - Page 296-155-475 Scope and application. 1 296-155-47501 Definitions applicable to this part. 1 296-155-476 General requirements. 2 296-155-477. 2, Page i PART J STAIRWAYS WAC 296-155-475

More information

NEW YORK CITY DEPARTMENT OF BUILDINGS. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

NEW YORK CITY DEPARTMENT OF BUILDINGS. Notice of Public Hearing and Opportunity to Comment on Proposed Rule NEW YORK CITY DEPARTMENT OF BUILDINGS Notice of Public Hearing and Opportunity to Comment on Proposed Rule What are we proposing? The Department of Buildings (DOB) is proposing a new rule relating to the

More information

Building Guide. Introduction. Construction Design Requirements. Revised 31-Jan-2018 Adopted 01-Mar-2018

Building Guide. Introduction. Construction Design Requirements. Revised 31-Jan-2018 Adopted 01-Mar-2018 Building Guide Revised 31-Jan-2018 Adopted 01-Mar-2018 Introduction This guide is meant to outline policies as determined by the Vuecrest Board of Directors (hereinafter referred to as Board.) It is meant

More information

MAINE MEDICAL CENTER

MAINE MEDICAL CENTER MAINE MEDICAL CENTER Construction Projects at the East Tower, Visitor Garage, Central Utility Plant Construction Management Plan December 15, 2017 Prepared for: Portland Department of Planning & Urban

More information

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents. Certification: Commercial Building Inspector Exam ID: B2 Scope: A Commercial Building Inspector will be responsible for performing inspections of structures to determine compliance with the various Building

More information

Cherokee Nation Entertainment Casino Ramona, Oklahoma. WORK PACKAGE # 5A Metal and Structural Steel 09/01/11

Cherokee Nation Entertainment Casino Ramona, Oklahoma. WORK PACKAGE # 5A Metal and Structural Steel 09/01/11 SCOPE SUMMARY: DIVISION: 0 - LEGAL DOCUMENTS Complete; DIVISION: 1 - GENERAL REQUIREMENTS As Applicable; SECTION: 05 1200 - STRUCTURAL STEEL FRAMING Complete; SECTION: 05 2100 - STEEL JOIST FRAMING Complete;

More information

Basement Build-Out Guidelines

Basement Build-Out Guidelines Community Development Department Five Plaza Drive Woodridge, IL 60517-5014 (630) 719-4750 FAX (630) 719-2900 Basement Build-Out Guidelines The Village of Woodridge requires that a building permit be submitted

More information

Chapter 8 MINIMUM CONSTRUCTION STANDARDS

Chapter 8 MINIMUM CONSTRUCTION STANDARDS Chapter 8 MINIMUM CONSTRUCTION STANDARDS 4-8-1: ADOPTION OF MINIMUM CONSTRUCTION STANDARDS: 1/5/1 0 In the construction, erection, installation, alteration, repair, location, relocation, replacement to,

More information

Evanston Avidor Construction Site Management Plan AVIDOR EVANSTON APARTMENT BUILDING Oak Avenue. Evanston, IL 60201

Evanston Avidor Construction Site Management Plan AVIDOR EVANSTON APARTMENT BUILDING Oak Avenue. Evanston, IL 60201 Evanston Avidor Construction Site Management Plan AVIDOR EVANSTON APARTMENT BUILDING 1727 Oak Avenue Evanston, IL 60201 General Contractor Owner Architect Construction Management Plan Phase 1 3 October

More information

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507) City of North Mankato 1001 Belgrade Avenue North Mankato, MN 56003 (507) 625-4141 BUILDING PERMIT GUIDELINES Building Permits are required for all improvements with a value** of $300.00 or more. Sheds,

More information

Emerg. Contact: EMERGENCY CONTACT INFORMATION Fire Department Info: Municipal Police Info: County Sheriff Info: Dept Name: Dept Name: Dept Name:

Emerg. Contact: EMERGENCY CONTACT INFORMATION Fire Department Info: Municipal Police Info: County Sheriff Info: Dept Name: Dept Name: Dept Name: JOB DETAILS Company Name: Customer: Project Manager: Job Address: Nearest Intersection: Latitude: Date: Job Name: Job Supervisor: Emerg. Contact: Longitude: EMERGENCY CONTACT INFORMATION Fire Department

More information

RISK CONTROL MANUAL SCHOOL SAFETY CHECKLIST (sample)

RISK CONTROL MANUAL SCHOOL SAFETY CHECKLIST (sample) RISK CONTROL MANUAL SCHOOL SAFETY CHECKLIST (sample) The following checklist covers both physical condition of the facility and work practices of school personnel. On inspections, please be aware of potentially

More information

Commercial and Residential Projects (after appropriate Board approvals have been made if necessary):

Commercial and Residential Projects (after appropriate Board approvals have been made if necessary): Village of Lansing Office: 2405 N. Triphammer Rd. Hours: 9:00-1:00 Telephone: 257-0424 Ext. # 3 Email: codeofficer2@vlansing.org Commercial and Residential Projects (after appropriate Board approvals have

More information

SUNCHASER VACATION VILLAS FAIRMONT RESORT RECREATION CENTRE FAIRMONT HOT SPRINGS, BC

SUNCHASER VACATION VILLAS FAIRMONT RESORT RECREATION CENTRE FAIRMONT HOT SPRINGS, BC SUNCHASER VACATION VILLAS FAIRMONT RESORT RECREATION CENTRE FAIRMONT HOT SPRINGS, BC PROGRESS DRAW 1 October 26 th, 2015 LTA Consultants Inc. Professional Quantity Surveyors & Construction Cost Consultants

More information

Peter Amato, President Andrey Vishev, Executive Vice President Sandeep Gunnala, Vice President Mark Merollo, Director of Operations Jodie Lupo,

Peter Amato, President Andrey Vishev, Executive Vice President Sandeep Gunnala, Vice President Mark Merollo, Director of Operations Jodie Lupo, Peter Amato, President Andrey Vishev, Executive Vice President Sandeep Gunnala, Vice President Mark Merollo, Director of Operations Jodie Lupo, Business Development Manager Services Site Safety Plans (3

More information

SECTION SITE PREPARATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION SITE PREPARATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 311000 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

Southwest Health System Construction Newsletter October 21, 2017

Southwest Health System Construction Newsletter October 21, 2017 Southwest Health System A Week in Review Patient Wing Asphalt Base was completed this week in the north section of the parking lot Sheetrock is substantially complete and everything should be ready for

More information

811 Emerson St. - Demolition & Site Prep

811 Emerson St. - Demolition & Site Prep 811 Emerson St. - Demolition & Site Prep 811 Emerson St. Evanston, IL 60201 CA Focus Evanston Property Owner, LLC General Contractor Owner Architect Construction Management Plan Phase I January 24t h,

More information

Exhibit G. Construction Mitigation Plan

Exhibit G. Construction Mitigation Plan Exhibit G Construction Mitigation Plan Construction Period Mitigation 1. A construction period mitigation plan shall be prepared by the applicant for approval by the Public Works Department prior to issuance

More information

Architectural Breadth Study

Architectural Breadth Study Architectural Breadth Study The 5 th level of the is used as the facilities dining area. The space is compromised of a kitchen with offices and support areas, a large servery, a café, and a student, faculty,

More information