Series Sump and Sewage Systems

Size: px
Start display at page:

Download "Series Sump and Sewage Systems"

Transcription

1 Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13

2 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column Type Sump & Sewage Pumps. Built from the highest quality engineered components, these pumps can be supplied as replacement pumps or as part of a new installation. Armstrong systems are available with control panel, level controls, and sump pit cover plate. Sewage Series 0 & 2 Armstrong sump pumps are offered in two designs, engineered to handle a wide range of waste water pumping requirements. 0 Standard Features centerless ground stainless steel shaft Enclosed-type bronze impeller, keyed to shaft Cast iron inlet strainer Flexible coupling Plate-mounted alemite grease fittings Intermediate grease-lubricated bronze guide bearings for pit depths over ft. (1.2m) 2 Standard Features 1¼" (32mm) heavy-duty carbon steel shaft Heavy-duty grease-lubricated bronze guide bearings Enclosed-type bronze impeller Cast iron inlet strainer Flexible coupling Raised thrust bearing mounted in a dirt and moisture resistant housing Plate-mounted alemite grease fittings Intermediate grease-lubricated bronze guide bearings for pit depths over ft. (1.m) Flanged pump column pipe 2 Optional Features Pump conversion for condensate service consisting of water lubricated graphite pump bearings, stainless steel shaft and bronze impeller Water lubricated cutless rubber bearings stainless steel shaft Armstrong sump pump designs address the specific requirements for light-duty or heavyduty commercial applications such as: elevator pits, electrical tunnels, loading docks, drain tiles, laundry facilities, floor drains and condensate returns.

3 Sewage Series 0 Armstrong 0 Series sewage pumping systems for building, municipal and industrial applications provide a top-quality, reliable and long-lasting product. Sewage Series 0 Pumps Armstrong sewage pumps feature a screenless design, capable of handling waste material and sewage up to 2½" (mm) solids. Standard Features 1¼" (32mm) carbon steel shaft Gas-tight construction Raised thrust bearing mounted in a dirt and moisture resistant housing Cast iron 2-vane open-type impeller Floor plate mounted alemite grease fittings Grease-lubricated bronze guide bearings for pit depths over ft. (1.m) Flanged pump and column pipe Optional Features Water-lubricated cutless rubber bearings Water-lubricated graphite bearings stainless steel shaft

4 Series 000 Controls & Accessories Choose Armstrong pumping systems for reliability, efficiency and quality engineered products. Control Panel Armstrong Sump & Sewage systems are available with a variety of starting equipment choices. Features nema 1 control panel enclosure ul 0 or csa approved Main disconnect Thermal and short circuit protection using internal circuit breakers Failure protection with automatic transfer to nonoperating pump (duplex system) Control transformer with fused primary (ul 0) Power-on and pump-run indicating lights Hand-Off-Automatic selector switch Optional Features nema 2, 3,, x or 7 enclosure High level buzzer or " (1mm) bell, indicating light and silence reset push button Overload pilot lights Elapsed time meters Individual disconnect switches Electrical alternation (duplex system) Level Controls Ball and rod type float switch governs the control of pump operation based on sump liquid level. Level controls are mounted on a cast iron pedestal and bolted to sump cover plate. Features Copper ball, brass float rod and stops, float guide pipe and cast iron pedestal Mechanical alternator with emergency start position is supplied with duplex units Optional Features High level alarm devices are mounted on sump cover plate and can be provided in two types: a) nema 1 compression type switch with integral buzzer and alarm contract b) Ball & rod float switch, to be wired to separate alarm panel or alarm bell nema or nema 7 enclosure Bulb-type level controls supplied with mounting plate, electrical connectors, and level control support Cover Plate and Curb Frame Circular or square sump cover plate and curb frame can be supplied with openings for simplex or duplex pump configurations. Cover plate includes 3" (7mm) npt threaded vent and inspection cover. Senses static head pressure between media and bellows in the switch enclosure As liquid level rises, trapped air in compression pipe causes bellows to expand and trips the microswitch activating an external circuit as well as an integral alarm compression high water switch float switch

5 Composite Charts 170 rpm capacity - L/s 1 3 total head - feet E-3 0-1KB E-9 2-1KE E D E-3 2-2D E-3 2-2KE E-1 0-3D E E total head - meters E- 0 -D curve no. pump size max. solid size E-3 0 1A/bh Bilge Water only E D Bilge Water only E-3 2 2D Bilge Water only E-9 2 1KE Bilge Water only E-3 2 2KE Bilge Water only E-1 0 3D 2" (0mm) dia. E- 0 D 2AA/db" (mm) dia. E-71 0 E 2AA/db" (mm) dia. capacity - USgpm capacity - L/s E-0 2-1KE E- 2-2KE rpm total head - feet 9 E-3 0-2D E- 2 2D E-2 0-3D E-72 0-E 7 E- 0 -D curve no. pump size max. solid size E-3 0 2D Bilge Water only E- 2 2D Bilge Water only E-0 2 1KE Bilge Water only E- 2 2KE Bilge Water only total head - meters 3 E-2 0 3D 2 (0mm) dia. E- 0 D 2AA/db (mm) dia. E-72 0 E 2AA/db" (mm) dia capacity - USgpm

6 Series 000 Section & Parts List Series 0 Sump Pump Series 2 Sump Pump Series 0 Sewage Pump item no. description item no. description item no. description 1 Volute 12 Discharge Pipe Screw & Washer 332 Grease Fitting 2 Impeller 1 Cover Plate & Lower Bearing 333 Lock Nut 3 Lower Discharge Elbow 2 Cover Plate Screw 33 Shaft Volute Screw Motor Support 3 Impeller Key Discharge Flange 7 Motor Screw 31 Coupling Key 7 Discharge Flange Gasket 223 Support Screw 33 Pipe Nipple Flange Nut 22 Column Pipe 3 Pipe Coupling 9 Flange Bolt 2 Intermediate Bearing Screw 3 Tube Connector 11 Impeller Nut 22 Intermediate Bearing Nut 3 Elbow 11 Impeller Washer 3 Ball Bearing 37 Lubrication Tube 123 Strainer Intermediate Bearing Assembly 3 Bearing Collar 12 Discharge Pipe 31 Snap Ring 39 Bearing Frame Screw 1 Strainer Screw 321 Oil Seal 1 Coupling 12 Suction Plate 331 Grease Fitting 01 Motor 127 Discharge Elbow 03 Floor Plate

7 Dimensional Data round square round square cover plates - simplex units inches (mm) a sump size b motor frame size inches (mm) cover plates - duplex units inches (mm) pump size inches (mm) e 1½b 2d 2d 1½e 2½e 3d d e 2 () 2 (711) 3 (7) 3 (7) 1N (32) 1N (32) 1O () 1 () N () N () (72) 3 () (2) (2) 1O () 1O () 1N (32) (2) 2O (70) 2O (70) 3 (91) (1) (3) (3) 3O (9) 3O (9) 3N (3) (2) O (121) O (121) 2 (7) (11) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) (1219) (1372) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) (1372) 0 (2) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 0 (2) (17) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 72 (129) 7 (191) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 2 () 2 (711) 3 (7) 3 (7) 1N (32) 1N (32) 1O () 1 () N () N () (72) 3 () (2) (2) 1O () 1O () 1N (32) (2) 2O (70) 2O (70) 3 (91) (1) (3) (3) 3O (9) 3O (9) 3N (3) (2) O (121) O (121) 2 (7) (11) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) (1219) (1372) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) (1372) 0 (2) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 0 (2) (17) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 72 (129) 7 (191) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) series c 13tc 1tc 12tc 1tc 213tc 2tc tc tc 0 H (approx.) 2 & 0 H (approx.) a sump size b 1X (22) 21K () 1K (19) 22 (9) 17K () 22 (9) O (7) K () e 2N (7) 27O (70) 2O (7) ½b 2d 2d 1½e 2-1/2e 3d d e 3 (91) (1) 2 (1) 2 (1) 2N (7) 2N (7) 2O (70) 0 (0) 1O () 1O () 2 (7) (11) (2) (2) 1O () 1O () 1N (32) (2) 2O (70) 2O (70) (1219) (1372) 9 (229) 9 (229) O (121) O (121) N () 7 (17) O (1 O (1 12 (1372) 0 (2) () () O (1) O (1) N (133) (3) O (171) O (171) 1 0 (2) (17) () () O (1) O (1) N (133) (3) O (171) O (171) 1 72 (129) 7 (191) 12 () 12 () 7O (197) 7O (197) 7N (1) () O (222) O (222) 1 3 (91) (1) (3) (3) 3O (9) 3O (9) 3N (3) (2) O (121) O (121) 2 (7) (11) 9 (229) 9 (229) O (121) O (121) N () 7 (17) O (1) O (1) 11 (1219) (1372) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 12 (1372) 0 (2) () () O (1) O (1) N (133) (3) O (171) O (171) 1 0 (2) (17) () () O (1) O (1) N (133) (3) O (171) O (171) 1 72 (129) 7 (191) 13 (3) 13 (3) O (222) O (222) N (2) 11 (279) 9O (2) 9O (2) 1 sump depth in feet (m) no. of intermediate bearings 0 to 3. (0 to 1.07) (0) 0 0 to. (0 to 1.) (2+0) 0 to (1.2 to 1.9) (0) 1 to (1. to 2.) (2+0) 1. to (2 to 2.) (0) 2 9 to 12 (2.7 to 3.7) (2+0) 2 (0) 3 pump size 0 1½b 0 2d 2 2d 2 1½e 2 2½e 0 3d 0 d 0 e ½ (1) 7 (17) 11V (23) N (20) 11N (2) 9 (229) Y (27) 11Y (2) O f g pump discharge K (11) (127) 2N (7) 3 (7) 3 (7) (9) 7N (1) 7N (1) Screwed 1½" npt Screwed 2" npt Screwed 2" npt Screwed 1½" npt Screwed 2½" npt Screwed 3" npt Flanged " 1#asa Flanged " 1#asa k note 1: High water alarm furnished only when specified. note 2: Sump depth determined by actual job requirements. note 3: Series 0 and 2 have Vertical Discharge. Series 0 has Elbow Discharge. *Dimensions f, g, & h apply to both Simplex and Duplex units. Denotes minus dimension as centerline of pump is left of cover plate center.

8 Typical Specifications Furnish and install, as illustrated on the plans & specifications, an Armstrong Series 000 simplex or duplex pumping system. pumps - 0 Sump Pump shall be Model: 0 vertical centrifugal, flexible coupled for sump service. Each pump shall provide USgpm at feet of tdh at a speed of rpm. Pump length will be suitable for a pit depth of feet. The pump casing shall be cast iron with a bronze enclosed impeller complete with a cast iron inlet strainer. Pump shaft shall be one piece centerless ground stainless steel. Pump shaft shall be guided by grease lubricated upper ball bearing and intermediate bronze sleeve type column bearing(s). Pump column assembly is constructed of threaded steel schedule 0 pipe. Intermediate bearing(s) are greased by a lubrication system consisting of ¼" (.3mm) copper grease lines and Alemite fittings terminating at floor plate. pumps - 2 Sump Pump shall be Model: 2 vertical centrifugal, flexible coupled for sump service. Each pump shall provide USgpm at feet of tdh at a speed of rpm. Pump length will be suitable for a pit depth of feet. The pump casing shall be cast iron with a bronze enclosed impeller complete with a cast iron inlet strainer. Pump shaft shall be one piece 1¼" (32 mm) diameter carbon steel or turned and polished stainless steel. Pump Shaft shall be guided by grease lubricated upper ball bearing and intermediate bronze sleeve type column bearing(s). Flanged steel column assembly is complete with register fit guide bearing housings to ensure proper alignment. The upper bearing(s) will be ball type, heavy duty grease lubricated, mounted in a raised bearing housing to prevent moisture, and dust and dirt contact. Intermediate and lower bearing(s) are greased by a lubrication system consisting of ¼" (.3 mm) copper grease lines and Alemite fitting(s) terminating at floor plate. pumps - 0 Sewage Pump shall be Model: 0 vertical centrifugal, flexible coupled for sewage service. Each pump shall provide USgpm at feet of tdh at a speed of rpm. Pump length will be suitable for a pit depth of feet. Pump shall be capable of passing solids sizes of 2" (1 mm) and 2½" ( mm). The pump casing shall be cast iron complete with a non-clog cast iron 2 vane open type impeller. Pump shaft shall be one piece 1¼" (32 mm) diameter carbon steel or turned and polished stainless steel. Pump shaft shall be guided by grease lubricated upper ball bearing(s) and intermediate bronze sleeve type column bearing(s). Flanged steel column assembly is complete with register fit guide bearing housings to ensure proper alignment. Packing seal provides GAS TIGHT construction. The upper bearing(s) will be a ball type, heavy duty grease lubricated, mounted in a raised bearing housing to prevent moisture, and dust and dirt contact. Intermediate and lower bearing(s) are greased by a lubrication system consisting of ¼" (.3 mm) copper grease lines and Alemite fitting(s) terminating at floor plate. motor Pump motor shall be a vertical type round body design. Motor horsepower shall be not less than hp, volts, phase, 0 Hz. Motor Enclosure shall be odp, tefc or Explosion Proof. optional construction: 2 & 0 pumps Cutless Rubber Lower & Intermediate Sleeve Bearings: Cutless Rubber Lower & Intermediate Sleeve Bearings are provided to handle abrasive liquids without scoring or damaging the shaft. A separate fresh water line connection is provided for connection to outside source with solenoid valve (supplied by others) to be energized when pump motor operates. Pumps are complete with stainless steel shaft for longer bearing life. Graphite Lower & Intermediate Bearings: Graphalloy intermediate and lower bearings are provided to handle liquids above 0 f ( c). Pump is complete with stainless steel shaft for longer bearing life. For condensate applications, pump is complete with bronze impeller. pump control Pump control shall be ball & rod mechanical float switch. Unit consists of copper ball, brass rod & stops. Float switch is mounted on a cast iron pedestal and bolted to sump cover plate. Duplex unit with mechanical alternating float switch complete with high level emergency start position turning on both pumps in case of high liquid level. high level alarm System shall include compression type high water alarm complete with alarm buzzer and additional contact for remote signaling. Alarm shall be housed in a nema 1 enclosure and mounted on sump cover plate. control panel Armstrong series 000 systems shall include nema 1 Control Panel with the following Standard Features: ul 0 or csa approved Main Disconnect Thermal and Short Circuit Protection using Internal Circuit Breakers Failure Protection with Automatic Transfer to Non-Operating Pump (Duplex System) Control Transformer with Fused Primary (ul 0 only) Power-On and Pump-Run Indicating Light Hand-Off-Automatic Selector Switch optional control features nema 2, 3,, x or 7 Enclosure High Level Buzzer or " (1 mm) Bell, Indicating Light and Silence Reset Push Button Overload Pilot Lights Elapsed Time Meters Individual Disconnect Switches cover plate and curb frame Circular or square sump cover plate and curb frame shall be supplied with openings for simplex and duplex pump configurations. Cover plate includes 3" (7 mm) npt threaded vent and inspection cover. S. A. Armstrong Limited 23 Bertrand Avenue Toronto, Ontario Canada, M1L 2P3 T: F: Armstrong Pumps Inc. 93 East Avenue North Tonawanda, New York U.S.A., 11-9 T: F: Armstrong Integrated Limited Wenlock Way Manchester United Kingdom, M12 JL T: + (0) 1 1 F: + (0) 1 1 S. A. Armstrong Limited 13 For Armstrong locations worldwide, please visit

Index - Section 40M Medium Sump / Drainage Pumps Bulletins 4508

Index - Section 40M Medium Sump / Drainage Pumps Bulletins 4508 www.cranepumps.com Index - Section Medium Sump / Drainage Pumps Bulletins 4508 ITEM S Pump Specifi cations... Pump Assembly - Type A... Pump Assembly - Type B... Pump Data... 4 Dimensions - Simplex & Duplex...

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series

More information

VSS S U B M E R S I B L E S E W A G E P U M P S

VSS S U B M E R S I B L E S E W A G E P U M P S 7 2 9 8 / 2 3 HP % % 64% 7 5 HP HP 5 HP % % C u r v e P a g e V S S - 4 5 R P M M O D E L : V S S - 4 E I M P E L L E R : V S A - 4 C - 2-5 A l s o a p p l i e s t o V S S - 5 E & V S S - 6 E 7 7 65 55

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Vertical

More information

SERIES 800 Quality Design Features Assure Long, Trouble-Free Service

SERIES 800 Quality Design Features Assure Long, Trouble-Free Service Heavy Duty Sump Pumps SERIES Quality Design Features Assure Long, Trouble-Free Service WIDE RANGE OF APPLICATIONS: Industrial Process Pollution Control Sump Drainage Flood Control Hazardous, Toxic & Inflammable

More information

t y p e V S A S E W A G E P U M P

t y p e V S A S E W A G E P U M P Pe r fo r m a n ce C h a r t 65 6 55 45 4 35 3 25 2 12 11 1 / 2 11 1 1 / 2 1 9 1 / 2 6% 7% 76% 7 1 HP 1/2 HP HP 76% 7% 6% C u r v e P a g e V S A - 5 1 1 5 R P M M O D E L : V S A - 6 H D I S C H A R G

More information

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING Flows to 200 GPM. TDH to 95 Feet at 1750 RPM Free Standing or Guide Rail Design. Available in Standard Submersible or Explosion Proof Design. Provided with 25 feet of submersible motor power cable. Cast

More information

SUGGESTED SPECIFICATIONS

SUGGESTED SPECIFICATIONS SUGGESTED SPECIFICATIONS SERIES 3000 SUSPENDED, SCREENED WET-PIT PUMPS PART 1 GENERAL 1.1 DESCRIPTION Work Included: Under this section, the contractor shall provide all labor, equipment and material necessary

More information

SUGGESTED SPECIFICATIONS Pump Frames through 64132

SUGGESTED SPECIFICATIONS Pump Frames through 64132 TYPE HBB - HORIZONTAL SOLIDS-HANDLING WASTEWATER PUMPS Pump Frames 44081 through 64132 GENERAL Furnish and install Horizontal Flexible Coupled Dry Pit Pumping Units complete with all accessories and appurtenances

More information

High Light. Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation

High Light. Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation High Light Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation Easy installation and removal For sump and rain water Control

More information

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR PERFORMANCE DATA Wholesale Products Page: 7140-1 Dated: August 2002 Supersedes: May 2002 RPM: 1550 Discharge: 2 Solids: 2 8 25 7 20 5 4/10 HP HEAD-METERS 4 HEAD-FEET 15 3 10 2 0 0 20 40 60 80 Capacity-U.S.

More information

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems: SECTION 221429 - SUMP PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal High Light Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal For sump and rain water Control system available Fiberglass

More information

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related

More information

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 22 13 33 PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph

More information

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals. Page 221429-1 SECTION 221429 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.

SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M. Performance RPM: 1750 Discharge: 2" Solids: 2" Wholesale Products Page: 6270-1 Section: Performance 12 40 9 30 HEAD-METERS 6 3 TOTAL HEAD IN FEET 20 10 SK60 0 0 Capacity-U.S. G.P.M. 20 40 60 80 100 120

More information

B. Wiring Diagrams: For power, signal, and control wiring.

B. Wiring Diagrams: For power, signal, and control wiring. Page 221429-1 SECTION 221429 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SD/SW/VS50 SD50 SW50 VS50

SD/SW/VS50 SD50 SW50 VS50 Performance RPM: 1550 Discharge: 1-1/2" Solids: 3/4" Wholesale Products Page: 7130-1 Section: Performance SD50 SW50 VS50 The curves reflect maximum performance characteristics without exceeding full load

More information

High Light. Motors are fully submersible Pumps can handle up to ½ spherical solids Indoor and outdoor installation Easy installation and removal

High Light. Motors are fully submersible Pumps can handle up to ½ spherical solids Indoor and outdoor installation Easy installation and removal High Light Motors are fully submersible Pumps can handle up to ½ spherical solids Indoor and outdoor installation Easy installation and removal Built-in automatic float switch option For sump and rain

More information

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS SECTION 22 14 36 PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also delete any other item or paragraph

More information

SUBMERSIBLE SEWAGE EJECTOR

SUBMERSIBLE SEWAGE EJECTOR PERFORMANCE DATA Wholesale Products Page: 6270-1 RPM: 1750 Discharge: 2 Solids: 2 12 40 HEAD-METERS 9 6 3 TOTAL HEAD IN FEET 30 20 10 SK60 0 0 Capacity-U.S. G.P.M. 0 20 40 60 80 100 120 Liters/Second 0

More information

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001 Performance RPM: 1550 Discharge: 1-1/2" Solids: 3/4" Wholesale Products Page: 6680-1 Section: Performance Dated: April 2002 Supersedes: January 2001 The curves reflect maximum performance characteristics

More information

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M. Performance SK75/100 RPM: 1750 Discharge: 2" Solids: 2" Wholesale Products Page: 6300-1 Section: Performance 12 40 9 30 HEAD-METERS 6 3 TOTAL HEAD IN FEET 20 10 SK75 SK100 0 0 Capacity-U.S. G.P.M. 20 40

More information

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007 Performance SPX50 RPM: 1750 Discharge: 2" Solids: 2" SPX50H RPM: 1750 Discharge: 1 1 2" Solids: 3 4" Wholesale Products Page: 6800-1 Section: Performance The curves reflect maximum performance characteristics

More information

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2. PERFORMANCE DATA Wholesale Products Page: 6280-1 RPM: 1650 Discharge: 2 Solids: 2 12 40 9 30 HEAD-METERS 6 HEAD-FEET 20 3 10 0 0 Capacity - U.S. G.P.M. 0 30 60 90 120 150 180 Liters/Second 0 2 4 6 8 10

More information

HPGR200 2 HP. Capacity-U.S. G.P.M.

HPGR200 2 HP. Capacity-U.S. G.P.M. Performance RPM: 3450 Discharge: 1-1/4" Solids: 2" Wholesale Products Page: 6710-1 Section: Performance 100 80 2 HP TOTAL HEAD IN FEET 60 40 20 0 0 10 20 30 40 50 Capacity-U.S. G.P.M. 60 The curves reflect

More information

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1 Solids: 1/8 GPM: TDH: Performance RPM: 1550 Discharge: 1" Solids: 1/8" Wholesale Products Page: 6660-1 Section: Performance The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower.

More information

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT PERFORMANCE DATA Wholesale Products Page: 6570-1 RPM: 1550 Discharge: 1 ½ Solids: ½ V-A1 W-A1 D-A1 Head, meters 8 4 Head, feet 30 20 10.3 HP 0 0 Capacity, US GPM 0 10 20 30 40 50 60 liters/second 0.0 1.0

More information

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 13 00 _SANITARY SEWER PIPING SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sanitary sewer piping buried 2. Sanitary

More information

Submersible Axial Flow Propeller Pumps

Submersible Axial Flow Propeller Pumps Submersible Axial Flow Propeller Pumps water wastewater flood control EBARA Fluid Handling an EBARA International Corporation company Features Watertight cable entry system prevents capillary action and

More information

SECTION INFLUENT EQUALIZATION TANK PUMPS

SECTION INFLUENT EQUALIZATION TANK PUMPS PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor and equipment to put into service the Influent Equalization Pumps in accordance with the Contract Drawings

More information

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump Pump Specifications 450 Series 1/2 hp Submersible Sump Pump 450_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 450-Series Dimensional

More information

SECTION PACKAGE BOOSTER PUMP STATIONS

SECTION PACKAGE BOOSTER PUMP STATIONS SECTION 331223 PACKAGE BOOSTER PUMP STATIONS Scope: The Contractor shall install a pump station at two locations to be determined by the Owner. These pump stations shall be designed to deliver flow to

More information

SECTION COOLING TOWER

SECTION COOLING TOWER PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue

More information

SECTION SLUDGE HOLDING TANK DECANTER PUMP

SECTION SLUDGE HOLDING TANK DECANTER PUMP PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor and equipment to put into service the Sludge Holding Tank Decanter Pumping System in accordance with the

More information

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted) 1DIVISION 15- MECHANICAL Section 15320 Fire Pumps 1.00 PART 1 -GENERAL 1.01 DESCRIPTION OF WORK: A. Provide pumps for fire suppression. 1.02 SECTION INCLUDES: A. Single Stage, Double Suction, 9100 Series

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 14 00 _STORM WATER PIPING SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Storm water piping 2. Roof drains. 3. Area

More information

2. Water Pressure Booster Systems. 3. Duplex Pedestal Type Sump Pumps.

2. Water Pressure Booster Systems. 3. Duplex Pedestal Type Sump Pumps. PART 1: GENERAL 1.01 Purpose: A. The design guidelines contained herein includes the requirements for pumps utilized for plumbing systems at Texas State University. It is the intention of this document

More information

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

SINGLE STAGE END SUCTION PUMPS AURORA Series.  Distributed By: Model 3804 Model 3804 AURORA 3800 Series SINGLE STAGE END SUCTION PUMPS Distributed By: Flow-Tech Industries 4601 South Pinemont, Suite 100 Houston, Texas 77041 Phone: 713.690.7474 Fax: 409.882.0254 sales@flow-tech.com

More information

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372. W ST IND TRY FIR US ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS Certified to NSF/ANSI 372 www.fairbanksnijhuis.com FAIRBANKS NIJHUIS 1600 SERIES Single Stage End Suction Pumps

More information

JDL Submersible Grinder Pumps TABLE OF CONTENTS Project: Model: Chk d: Date:

JDL Submersible Grinder Pumps TABLE OF CONTENTS Project: Model: Chk d: Date: JCG, JCSG(E) TABLE OF CONTENTS JDL MODEL JCSG 1¼JCG2S (2HP) 1¼JCSG2S (2 HP) 1¼JCSG2 (2 HP) 2JCSG3S (3 HP) 2JCSG3 (3 HP) 2JCSG5S (5 HP) 2JCSG5 (5 HP) Section Page G1-1 Selection Chart G1-2 Performance Curves

More information

DIVISION 15- MECHANICAL Section Fire Pumps

DIVISION 15- MECHANICAL Section Fire Pumps DIVISION 15- MECHANICAL Section 15320 Fire Pumps 1.00 PART 1 -GENERAL 1.01 DESCRIPTION OF WORK: A. Provide pumps for fire suppression. 1.02 SECTION INCLUDES: A. Vertical Turbine Fire Pump RELATED DOCUMENTS:

More information

DSC/DSCA3. EBARA Submersible Sewage Pumps Contents. Project: Model: Chk d: Date: Model

DSC/DSCA3. EBARA Submersible Sewage Pumps Contents. Project: Model: Chk d: Date: Model Contents Model 150DSC3 250x150DSCA3 350x250DSCA3 500x400DSCA3 200DSC3 300x150DSCA3 400x250DSCA3 600x500DSCA3 250DSC3 250x200DSCA3 350x300DSCA3 750x500DSCA3 300DSC3 300x200DSCA3 400x300DSCA3 750x600DSCA3

More information

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011 100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the

More information

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP Model T00718 REPAIR PARTS REF. PART DESCRIPTION 1 310883 Upper casing 2 310885 Motor housing 3 310889 Stator 4 310887 Shaft / rotor 5 310895 Mechanical seal 6 310892 Impeller 7 310893 Strainer 8 310890

More information

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011 100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the

More information

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS. FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Introduction Fairbanks Nijhuis manufactures a complete line of submersible pumps for municipal and industrial

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING ENVIRONMENTAL, HEALTH & SAFETY

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING ENVIRONMENTAL, HEALTH & SAFETY CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING ENVIRONMENTAL, HEALTH & SAFETY SPECIFICATION EO 5132 JULY 2007 EFFECTIVE DATE AUGUST 1, 2007 SUMP

More information

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS. FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Introduction Fairbanks Nijhuis manufactures a complete line of submersible pumps for municipal and industrial

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps N N O V A T I O N E F F I C I E N C Y Q U A L I T Y Vertical Sump Pumps For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology Ruhrpumpen

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps N N O V A T I O N E F F I C I E N C Y Q U A L I T Y Vertical Sump Pumps For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology Ruhrpumpen

More information

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART (For Cast Iron and Concrete Pipes See Note at Right) Lay a straightedge on scales

More information

Goulds API ISO / API 610 VS4 Vertical Sump Pump

Goulds API ISO / API 610 VS4 Vertical Sump Pump Goulds API 3171 ISO 13709 / API 610 VS4 Vertical Sump Pump API 3171 ISO 13709 / API 610 11 th edition, compliant VS4 sump pump Capacities to 680 m³/h (3000 GPM) Heads to 290 m (950 feet) Temperatures to

More information

SECTION PLUMBING PIPING

SECTION PLUMBING PIPING PRT1 GENERL 1.01 SECTION INCLUDES SECTION 22 1005 PLUMBING PIPING Pipe, pipe fittings, specialties, and connections for piping systems. 1. Domestic water. 2. Storm water. 3. Flanges, unions, and couplings.

More information

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 -PERFORMANCE CURVES Performance Curve Best One 200 Performance

More information

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS DIVISION 33 UTILITIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: The work specified in this Section consists of providing an Environmental One grinder pump(s) unit with tank, internal piping and

More information

T Series. Self-Priming Centrifugal Pumps

T Series. Self-Priming Centrifugal Pumps T Series Self-Priming Centrifugal Pumps The World Leader in Solids Handling Self-Priming Pumps. When industry looks for more reliable and efficient ways to move waste, they look to Gorman-Rupp self-priming

More information

Series A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100

Series A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100 Series A-C 9100 Single Stage Double Suction Large Split Case TECHNICAL Brochure BAC9100 TABLE OF CONTENTS Useful Pump Formulas 2 Pump Engineering Data 3 Materials of Construction 4 Exploded View 6 USEFUL

More information

Series 4300 Vertical in-line

Series 4300 Vertical in-line Series 4300 Vertical in-line Equal suction & discharge 'M' designation Parts list tc motors only, groups 5 to 20 1N" impeller bore 1X" mechanical seal File No: 6043.134 Date: november 20, 2015 Supersedes:

More information

& ACCESSORIES WASTEWATERTER PUMPSUMPS -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS

& ACCESSORIES WASTEWATERTER PUMPSUMPS -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS WASTEWATERTER PUMPSUMPS & ACCESSORIES -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS Weber Industries, Inc 8417 New Hampshire Ave. St. Louis, MO 63123

More information

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11931 - Horizontal Centrifugal Water Pumps C O N T E N T S PART 1 - GENERAL... 1 1.01 PUMP - GENERAL... 1 1.02 CERTIFIED PUMP CURVES... 1 1.03 NPSH REQUIREMENTS...

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTG. Vertical Turbine Generator

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTG. Vertical Turbine Generator N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTG For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology Ruhrpumpen is an

More information

G2S. Vertical Sump Pump

G2S. Vertical Sump Pump G2S Vertical Sump Pump G2S Our process-duty vertical sump pump for water, hydrocarbons, and acid and alkaline solutions. Modular in design, the G2S sump pump is made This pump comes standard with lip seals

More information

SUGGESTED SPECIFICATIONS

SUGGESTED SPECIFICATIONS SOLIDS-HANDLING SUBMERSIBLE DRY-PIT PUMPS PART 1 GENERAL 1.1 DESCRIPTION Work Included: Under this section, the contractor shall provide all labor, equipment and material necessary to furnish, install,

More information

The following shall be incorporated into the Contract Documents dated 8 August 2018

The following shall be incorporated into the Contract Documents dated 8 August 2018 ADDENDUM NO. 1 DATE: September 10, 2018 PROJECT: OWNER: Utility Infrastructure Improvements and Extension BID DATE: Tuesday, September 25, 2018 The following shall be incorporated into the Contract Documents

More information

SECTION HVAC PUMPS. A. Provide centrifugal HVAC pumps, called for in drawing schedule, and as needed for a complete and proper installation.

SECTION HVAC PUMPS. A. Provide centrifugal HVAC pumps, called for in drawing schedule, and as needed for a complete and proper installation. PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 15540 HVAC PUMPS A. Provide centrifugal HVAC pumps, called for in drawing schedule, and as needed for a complete and proper installation. B. Provide variable

More information

SECTION SUBMERSIBLE GRINDER PUMPS FOR WASTEWATER (LESS THAN 10 HORSEPOWER)

SECTION SUBMERSIBLE GRINDER PUMPS FOR WASTEWATER (LESS THAN 10 HORSEPOWER) SECTION SUBMERSIBLE GRINDER PUMPS FOR WASTEWATER (LESS THAN 10 HORSEPOWER) 1. DESCRIPTION This specification shall govern all work necessary for furnishing, installing, and placing into operation, heavy

More information

Goulds Multistage Process Pumps

Goulds Multistage Process Pumps Goulds 3355 Multistage Process Pumps Multiple nozzle orientations to fit your piping configurations. Radial Suction Configuration. Radial nozzles are rotatable at 90 increments. Goulds Model 3355 Multistage

More information

SECTION 2110 PRODUCT INFORMATION TYPE HBB SOLIDS-HANDLING WASTEWATER PUMPS COMPLETE HBB PUMP INCLUDES:

SECTION 2110 PRODUCT INFORMATION TYPE HBB SOLIDS-HANDLING WASTEWATER PUMPS COMPLETE HBB PUMP INCLUDES: TYPE HBB D B A E COMPLETE HBB PUMP INCLUDES: A. HORIZONTAL PUMP UNIT, INCUDING DISCHARGE CASING ASSEMBLY, BEARING HOUSING AND CLEANOUT HANDHOLE W/ COVER (NOT SHOWN) B. FLEXIBLE COUPLING C. COUPLING GUARD

More information

NUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A

NUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 DATA SHEET A ANNEXURE - A Sr. Item Description Sr. Item Description A. GENERAL DATA B. PUMP DUTY PARAMETERS 1. System Name 1. Rated capacity,

More information

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer. Construction of Sodium Hypochlorite and Chemical Storage Buildings Page 1 of 7 1. GENERAL 1.1 Scope.1 Boiler feed tank and pumps..2 Blowdown tanks..3 Water Softener System 1.2 Quality Assurance.1 All equipment,

More information

C o l u m n S u m p P u m p s

C o l u m n S u m p P u m p s Column Sump Pumps Column Sump Pumps Regent Column Sump Pumps are column versions of the popular Regent end suction centrifugal models. This style of pump is advantageous when pumping high temperature liquids

More information

SPECIFYING PUMPS WHY DO PUMPS FAIL.

SPECIFYING PUMPS WHY DO PUMPS FAIL. SPECIFYING PUMPS WHY DO PUMPS FAIL 1 www.sspma.org SSPMA Sump and Sewage Pump Manufacturers Association Since 1956, we are a North American trade organization of sump, effluent, and sewage pump manufacturers

More information

Rugged, reliable and efficient sump pumps... your assurance of a dry basement!

Rugged, reliable and efficient sump pumps... your assurance of a dry basement! Rugged, reliable and efficient sump pumps... your assurance of a dry basement! TITAN sump pumps provide the performance, value and simplicity you need for your home, farm, cottage or business...count on

More information

BERKELEY FAIRBANKS NIJHUIS GLOBAL IRRIGATION.

BERKELEY FAIRBANKS NIJHUIS GLOBAL IRRIGATION. BERKELEY FAIRBANKS NIJHUIS GLOBAL IRRIGATION www.berkeleypumps.com www.fairbanksnijhuis.com HISTORY OF BERKELEY Where we began Our history assures you a trouble-free future. After three quarters of a century,

More information

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 23 81 00 DECENTRALIZED HVAC EQUIPMENT A. The other Contract Documents complement the requirements of this section. The General requirements apply to the work

More information

CombiSump. Sump pump

CombiSump. Sump pump CombiSump Sump pump CombiSump Centrifugal sump pump CombiSump is the sump pump solution for thin liquids. The pump is part of Johnson Pump s Combi-system, a modular programme of single stage centrifugal

More information

Manufacturing Program: LAND APPLICATIONS. Propeller Pumps

Manufacturing Program: LAND APPLICATIONS. Propeller Pumps Propeller Pumps type PV APPLICATIONS Vertical propeller pumps for pumping clean and treated liquids, without the presence of important solid bodies such as: cooling water, drinking water, hot water, sea

More information

CombiSump. Vertical long shaft sump pump,according to ISO 2858,EN 733 (DIN 24255), API 610

CombiSump. Vertical long shaft sump pump,according to ISO 2858,EN 733 (DIN 24255), API 610 CombiSump Vertical long shaft sump pump,according to ISO 2858,EN 733 (DIN 24255), API 610 CombiSump CombiSump is the sump pump solution for thin liquids. The pump is part of Johnson Pump s Combi-system,

More information

MODEL 16ASX T/S - SPECIFICATION

MODEL 16ASX T/S - SPECIFICATION MODEL 16ASX T/S - SPECIFICATION 1.0 General Specifications TM There will be furnished one (1) only Grind Hog Model 16ASX T/S Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a

More information

u m p a n d u m p i n g y s t e m p e c i a l i s t s i n c e

u m p a n d u m p i n g y s t e m p e c i a l i s t s i n c e P P S S S u m p a n d u m p i n g y s t e m p e c i a l i s t s i n c e 1 9 6 2 Ft Worth Waco Austin Houston San Antonio 2 3 Vertical Turbine Fabricated Steel Components Smith Pump specializes in engineered

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART 204 PERFORMANCE CHART VOX 205 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART 204 PERFORMANCE CHART VOX 205 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW

More information

Goulds Two Stage, Horizontally Split Case Pump

Goulds Two Stage, Horizontally Split Case Pump Goulds 3316 Two Stage, Horizontally Split Case Pump 3316 Two Stage, Horizontally Split Case Pumps designed for boiler feed, mine dewatering and other applications requiring moderately high heads with a

More information

Series 4380 Vertical in-line

Series 4380 Vertical in-line Series 4380 Vertical in-line Equal suction & discharge 'M' designation Parts list 1N" impeller bore 1X" mechanical seal File No: 6043.130 Date: october 07, 2015 Supersedes: 6043.130 Date: december 22,

More information

University of Houston Master Construction Specifications Insert Project Name SECTION PLUMBING PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS:

University of Houston Master Construction Specifications Insert Project Name SECTION PLUMBING PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: SECTION 22 10 00 - PLUMBING PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00, "Mechanical

More information

MODELS PH PH PH

MODELS PH PH PH WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

FXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2

FXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2 - C 1 Product Detail Engineering Data Models... C2 Structural Support Models... C6 Engineering Specifications... C8 - C 2 Engineering Data Models REMARK: Do not use for construction. Refer to factory certified

More information

SECTION CHEMICAL FEED SYSTEM

SECTION CHEMICAL FEED SYSTEM SECTION 11800 PART 1 GENERAL 1.1 SUMMARY A. This section includes the requirements for the chemical feed system shall be a complete turnkey system inclusive of all necessary fluid handling and ancillary

More information

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Hannah Yan. Mobile/Skype/WhatsAPP: Wechat:yhr MSP HEAVY DUTY SUMP PUMPS

Hannah Yan. Mobile/Skype/WhatsAPP: Wechat:yhr MSP HEAVY DUTY SUMP PUMPS Hannah Yan Email:info@deponpump.cn Mobile/Skype/WhatsAPP:+86 11 32 3669 Wechat:yhr1381 MSP HEAVY DUTY SUMP PUMPS MSP HEAVY DUTY SUMP PUMPS Vertical, shaft driven centrifugal slurry pumps. Rugged pumping

More information

Specifying Pumps Why Do Pumps Fail.

Specifying Pumps Why Do Pumps Fail. Specifying Pumps Why Do Pumps Fail 1 www.sspma.org SSPMA Sump and Sewage Pump Manufacturers Association Since 1956, we are a North American trade organization of sump, effluent, and sewage pump manufacturers

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.burcam.com 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com INSTALLATION INSTRUCTIONS MODELS 300618 300628 300728 300718 SUMP PUMPS Your pump

More information

TOP Pre-engineered Fiberglass Pump Station

TOP Pre-engineered Fiberglass Pump Station TOP Pre-engineered Fiberglass Pump Station The Optimum Pump Station Flygt pump station controls Xylem offers offers a fully engineered control panel solution. Our integrated, purposely designed control

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11938 - Progressing Cavity Pump C O N T E N T S PART 1 - GENERAL... 1 1.01 GENERAL... 1 1.02 RELATED SPECIFICATION SECTIONS... 1 1.03 MANUFACTURERS... 1 PART

More information

CombiSump. Vertical long shaft sump pump, according to ISO 2858, EN 733, API 610 (VS4)

CombiSump. Vertical long shaft sump pump, according to ISO 2858, EN 733, API 610 (VS4) CombiSump Vertical long shaft sump pump, according to ISO 2858, EN 33, API 6 (VS4) Johnson Pump, An SPX FLOW Brand CombiSump SPX FLOW develops, manufactures and markets Johnson Pump branded positive displacement

More information