Thin Brick Façade. Façades Installation Guide

Size: px
Start display at page:

Download "Thin Brick Façade. Façades Installation Guide"

Transcription

1 Thin Brick Façade Façades Installation Guide October 2016

2 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels. Insulated panels serve as energy efficient, state-of-the-art alternative to traditional construction. This document serves as installation guidelines for the BENCHMARK By Kingspan Thin Brick Facade system. Disclaimer This installation guide is only to be used in conjunction with panel installation drawings and Kingspan recommended details. Details shown in project shop drawings prepared by Kingspan take precedence over any similar information in this manual. This guide is intended to provide the panel contractor with recommended methods, procedures and guidelines for the installation of the Thin Brick façade system for architectural applications. Information presented is accurate but may not cover all situations, building conditions and/or details of your specific project. Consult Kingspan Technical Services where this guide does not cover your unique construction requirements. It is the sole responsibility of the project engineer and panel installer to ensure specified air and weather tightness of a building by good design and workmanship in accordance with approved drawings using only the appropriate type of sealants. It is the sole responsibility of the owner s representative and panel installer to maintain quality workmanship in accordance with approved shop drawings to ensure the best performance of the wall system. Kingspan recommends installers read this document fully before receiving the panels on the job site. Installation classes are available through Kingspan s Technical Services Department. Please call for more information. Follow the approved shop drawings and engineering calculations for your project specific fastening patterns. The engineer of record is responsible for verifying applicable design loads and panel fastening requirements. All safety procedures, including adequate fall protection, are the responsibility of the panel contractor. 2

3 CONTENTS Introduction 4 Installation At Base and Corner 7 At Sill 10 At Jamb 12 At Head 14 Mortar 16 Construction Details 18 Materials 22 Notes 23 3

4 1. INTRODUCTION FAÇADES 1 1 BENCHMARK By Kingspan Insulated Metal Panel (Barrier Wall) 2 BENCHMARK By Kingspan KarrierRail 3 Subgirt 4 Thin Brick Holding Tray 5 Thin Brick 6 Thin Brick Mortar

5 DETERMINING TRAY STARTING POINT One of the advantages of the Thin Brick system is that you can start tray installation at any point on the wall. The steel holding trays may be installed from the bottom working up a wall or from the top working down the wall. The key considerations in finding a starting point are: Finding a low starting point that will allow you to easily keep the trays level. Determining how close to ground level you want to install trays. Analyzing all openings and determining a starting point that will minimize course adjustments. Finding a point that allows for easy chalk line markings. MARKING THE LOCATION OF THE FIRST STEEL HOLDING TRAY Once you have determined a starting point, you need to take measurements to assure that the trays are installed level and that trays will align at each corner. The easiest way to determine that the trays are installed level is to measure the distance from your starting point up to the building s soffit. Repeat this process with each framed opening until all have been measured. Trays that intersect at all corners must align or the thin brick corner units will not fit properly. MARKING VERTICAL COURSING LINES Thin Brick steel holding trays are 3.20 in height and 5 trays will course every 16 when installed snugly against each other. This is the ideal condition to maintain the optimum joint size and spacing. There will be times when you will spread the trays out slightly in order to adjust coursing to meet certain conditions, such as to meet the top of windows and doors with a full tile to avoid cuts and increase speed of installation.. The trays should never be separated more than 1/8 apart from their fully seated (snuggly fit together) normal installed condition FINDING AND MARKING WALL STUDS Prior to installing trays, it is helpful to locate and mark the location of wall studs. Marking the stud locations will speed up installation and prevent fasteners from being incorrectly installed in the exterior sheathing. 5

6 1. INTRODUCTION FAÇADES BRICK TRAY SIZES Brick trays are available in 12 foot lengths. When installing trays along a wall section that is longer than 12 feet, it is important to stagger the tray joints and maintain a minimum 16 offset in joint placement between adjacent trays (see Figure 1.1). Use the appropriate fastener and install a fastener at every KarrierRail along the length of each tray. Fig. 1.1 Continuous KarrierRail 16 Joints are located between KarrierRail Minimum one KarrierRail offset or 16 IMPORTANT NOTE It is important to check the entire length of every tray to be sure the trays are positioned correctly. If they are not positioned correctly, you may have to remove trays, which can cause hidden damage to the building. TRAY PLACEMENT IMPORTANT NOTE Joints between tray ends must always occur between two studs. Never attempt to join two tray ends at the same stud. Always maintain 1/8 gap between tray ends. 1/8 1/8 6

7 2. INSTALLATION AT BASE AND CORNER INSTALLING THE FIRST TRAY Align your first tray at the proper starting place. Using a screw gun, insert a fastener through the steel holding tray and into the closest stud. Tighten the screw until the screw head is flush with the tray surface. Before inserting another screw, check the alignment of the tray and make sure that it is aligned with the chalk line. Insert another screw through the steel holding tray and into the closest stud at the opposite end of the tray from the starting point. Check the alignment of the tray and finish inserting screws into every stud along the length of the tray. COMPLETING TRAY INSTALLATION AND JOINT STAGGERING You may install additional trays either moving up or down the wall depending on your starting point. The designed tray spacing is 3.2 which requires the flanges to be firmly seated and the backs of the trays touching each other. However, when you need to spread the trays slightly to meet certain conditions, the trays must never be spaced at more than 1/8 apart per course from their fully seated normal install condition. Make certain that every tray flange is firmly seated into the next tray. Use chalk lines and check for level as you install additional trays. Make certain that trays will meet precisely at all corners with the trays on the adjacent wall or corner tile will not work. STARTING WITH A THIN BRICK CORNER It is recommended to begin brick installation in the two steel holding trays immediately below the lowest window opening. If you are starting on a wall that requires corner units, begin the brick installation by inserting a corner brick (using the long end) at one end of the wall. Move to the other end of the wall and insert another corner. Begin filling the first tray completely with thin bricks, allowing 3/8-1/2 vertical head joints between all bricks, whichever works best for windows, doors and wall length. PROPER INSTALLATION OF THIN BRICK Each thin brick contains grooves on each long edg pered. Always install thin bricks with the tapered edge down. Insert a brick into the tray until the top groove fits into the top tray edge. Using a white rubber mallet, tap the bottom of the brick in an upward motion until the tray bottom edge snaps into the brick s bottom groove. TIP When installing trays, use the minimum amount of fasteners needed to hold the tray in place until all rails in that section have been placed. This will make adjusting the tray easier if necessary. 7

8 2. INSTALLATION AT BASE AND CORNER BRICK TRAY INSTALLATION You may install additional brick support trays, either moving up or down the wall depending on your starting point. The design tray spacing is 3.2 which requires the flanges to be firmly seated and the backs of the trays touching each other. However, when you need to spread the trays slightly to meet certain conditions, the trays must never be spaced more than 1/8 as shown in figure 2.1. NOTE When adjusting coursing by separating trays, 1/8 or less per course is recommended. 3/16 or more separation per course is not recommended. Use chalk lines and check for level as you install additional trays. Make certain that trays will meet precisely at all corners. Fig /8 maximum seperation 8

9 Base at Overhang Continuous KarrierRail (KarrierRail available in 1 3 faces) BENCHMARK thin brick Mortar joint Brick support tray BENCHMARK thin brick (bottom course transition option shown) Base flashing Expansion fastener as required Set KarrierRail in butyl sealant at fastener locations Continuous butyl sealant both sides of trim with marriage bead to vertical panel joint Fastener to concrete (not by Kingspan) Continuous butyl sealant Base angle with min. 3 vertical leg for panel attachment set in sealant (not by Kingspan) Outside Corner Hat channel set in butyl sealant at fastener locations 1/4 14 low profile fastener with 11/8 bonded washer Pop rivet Inside corner trim Outside corner trim Continuous butyl sealant F.I.P. insulation as required (not by Kingspan) 3/4 phil pan head BENCHMARK thin brick Pop rivet Brick support tray Hat channel set in butyl sealant at fastener locations Mortar joint Horizontal support (not by Kingspan) 9

10 2. INSTALLATION AT SILL 10

11 Framed Opening Sill Exposed sealant (not by Kingspan) Door / window frame (not by Kingspan) Continuous butyl sealant both sides of trim with marriage bead to vertical panel joint Miter cut joints where required Top leg of brick tray Sill trim BENCHMARK thin brick sill 1/4 14 through fastener Mortar joint BENCHMARK thin brick Brick support tray Sealant Expansion fastener as required Continuous KarrierRail (KarrierRail available in 1 3 faces) WINDOW SILL TREATMENT Using a BENCHMARK Thin Brick Sill is an easy and attractive method of installing BENCHMARK Thin Brick below windows. First, cut a piece of thin brick steel tray the same length as the width of the J-channel below the window or the bottom of the window frame (if J-channel was not used). Second, snap two Tru-Brix S6 sills into each end of the cut tray. Third, place the tray and sills directly below the bottom of the window frame. Slide the tray up until the top of each S6 sill is snug against the J-channel. If not using J-Channel, trim the top flange of the tray so the tray sits snugly against the bottom of the window frame or sill trim as shown above. Using your screw gun, apply fasteners until the tray is securely fastened. If J-channel was not used, apply a bead of highquality exterior sealant in the gap between the sill and the window frame. Next you must lay out the sills to determine if it is necessary to trim the sill bricks. Each sill measures 7 5/8 in length. After adding 3/8 for the mortar joint, an installed sill will measure 8. Re-measure the length of the tray you installed below the window. Divide this measurement by 8 to determine the quantity of sills required. It is important to trim the sills so that they are equal in length. NOTE The top leg of the tray can be trimmed off to allow a closer fit of sill brick to trim. Finally, remove the two sills and install fasteners at each end of the tray. 11

12 2. INSTALLATION AT JAMB 12

13 Framed Opening Jamb Door / window frame (not by Kingspan) Framed opening (not by Kingspan) 1/4 14 through fastener Exposed sealant (not by Kingspan) Sealant Backer rod and sealant (not by Kingspan) Continuous butyl sealant 1/4 14 low profile fastener with 1 1 /8 bonded washer Hat channel set in butyl sealant at fastener locations Tray may or may not be necessary here, depending on measurement. If measurement is greater than 3 3 /4, a steel tray is recommended. For all measurement below 3 3 /4 no steel tray is necessary. 13

14 2. INSTALLATION AT HEAD 14

15 Framed Opening Head Continuous KarrierRail (KarrierRail available in 1 3 faces) BENCHMARK thin brick Mortar joint Brick support tray Expansion fastener as required Framed opening (not by Kingspan) Drip flashing Continuous butyl sealant both sides of trim with marriage bead to vertical panel joint Exposed sealant (not by Kingspan) Door / window frame (not by Kingspan) 15

16 3. MORTAR PRE-MORTARING CHECKLIST Inspect all wall areas for any defects prior to starting the grouting process. Remove and replace any off color or broken bricks before grouting. Read and follow instructions. Mortar is available in 50lb bags which will cover approximately 27 square feet for modular bricks and approximately 32 square feet when used in conjunction with modular oversized bricks. CAUTION Useful life of mixed mortar is only 30 to 40 minutes. If you cannot use the entire batch in the alloted time, mix half batches of mortar. MORTAR MIXING INSTRUCTIONS Pour 6 quarts of water into a 5 gallon bucket. Pour 3/4 of a 50 lb bag of mortar into the bucket with 6 quarts of water. Mix thoroughly. Add the remaining dry mortar from the 50 lb bag into the 5 gallon bucket. Mix again until the right consistency is reached. Do not add more water if seems too dry - keep mixing it will get wetter. If water absolutely needs to be added, do so in very small amounts at a time. Re-temper (re-mix) every minutes or as necessary until mortar is used up. Be sure to only add a little bit of water when re-tempering. Work in a methodical fashion, 6-10 brick across at the bottom course and move up 1 course at time so when it s time to strike the mortar you begin at the same place you first put the mortar into the wall. Overfill the joint or there won t be enough mortar to strike. Don t strike too early or you will have a messy smeared wall. The mortar needs to setup to the point that it strikes well and the excess falls right off. CAUTION Be careful not to add too much water, which will make the mortar too thin. Soupy mortar may slump during application resulting in walls that will require cleaning after grouting. 16

17 PREPARING THE MORTAR POINTING GUN Once assembled, lightly spray WD40 or a similar lubricant into the gun s tube. Also lightly coat the rubber gasket attached to the gun s plunger. Using the scooper, fill the pointing gun cartridge completely with mortar. Begin filling the joints by starting with the vertical head joints. Work carefully to prevent excess mortar from dripping on the brick faces. After two rows of vertical head joints, begin filling the adjacent horizontal bed joints. CAUTION Make sure that all head joints are completely filled. If some joints are not completely filled, take mortar from a joint that has been overfilled. Simply scrape the excess off with the striking tool and apply the mortar to the joint that is underfilled. HINT If you spill mortar on to the faces of the bricks, wait until striking is completed before trying to remove the mortar droppings. If you immediately try to remove the droppings, the mortar will smear and cleaning may be required when finished grouting. 17

18 4. CONSTRUCTION DETAILS Stack Joint Expansion fastener as required Continuous KarrierRail (KarrierRail available in 1 3 faces) BENCHMARK thin brick Horizontal supports (not by Kingspan) Continuous butyl sealant with marriage bead to vertical panel joint Fastener as required (not by Kingspan) Mortar joint Brick support tray Parapet Parapet assembly Wrap membrane over brick (not by Kingspan) Continuous butyl sealant both sides of trim with marriage bead to vertical panel joint Parapet blocking (not by Kingspan) F.I.P. insulation as required (not by Kingspan) Fastener to parapet backer (not by Kingspan) Expansion fastener as required BENCHMARK thin brick Membrane roof and parapet backer (not by Kingspan) Brick support tray Mortar joint 18

19 Rake Refer to 900/1000 Series roof panel details for additional information Rake angle (not by Kingspan) F.I.P. insulation as required (not by Kingspan) Continuous butyl sealant both sides of trim with marriage bead to vertical panel joint Expansion fastener as required BENCHMARK thin brick Brick support tray Mortar joint Continuous KarrierRail (KarrierRail available in 1 3 faces) Low Eave Refer to 900/1000 Series roof panel details for additional information F.I.P. insulation as required (not by Kingspan) Brick support tray Expansion fastener as required Continuous butyl sealant both sides of trim with marriage bead to vertical panel joint Mortar joint BENCHMARK thin brick Eave strut (not by Kingspan) NOTE Rake should fasten through the mortar joint. Fastener holes should be pre-drilled. Do not fasten through the brick as bricks will crack. 19

20 4. CONSTRUCTION DETAILS Panel Termination Structural supports (not by Kingspan) Backer rod and sealant (not by Kingspan) 1/4 14 low profile fastener with 1 1 /8 bonded washer Continuous butyl sealant Hat channel set in butyl sealant at fastener locations BENCHMARK thin brick Brick support tray Cap trim Backer rod and sealant Inside Corner 3/4 phil pan head 1/4 14 low profile fastener with 1 1 /8 bonded washer Continuous butyl sealant Hat channel set in butyl sealant at fastener locations Inside corner trim F.I.P. insulation as required (not by Kingspan) Continuous butyl sealant 1/4 14 low profile fastener with 1 1 /8 bonded washer 3/4 phil pan head Pop rivet Mortar joint Outside corner trim Horizontal support (not by Kingspan) Brick support tray 20

21 Horizontal Expansion Joint Mortar joint BENCHMARK thin brick 2 1 /4 Vertical KarrierPanel Sealant on both sides Brick support tray with #8 x 3 /4 modified truss head #2 phillips drive self-drilling fasteners at each tray (24 O.C.) Girt (not by Kingspan) Continuous KarrierRail (KarrierRail available in 1 3 faces) Backer rod 3/4 horizontal expansion joint Sealant along horizontal expansion joint 3/4 Field cut KarrierRail Brick adhesive between brick tray and brick Flat trim 2 x #14 HH fasteners with bonded washers Vertical Expansion Joint #14 HH thru fastener with bonded washer at each steel support Vertical wall panel Steel Support (not by Kingspan) Sealant 16GA. hat-bar Brick support tray with #8 x 3 /4 modified truss head #2 phillips drive self-drilling fasteners at hat-bar Backer rod 3/4 Mortar joint BENCHMARK thin brick Flat trim 3/4 horizontal expansion joint Sealant along vertical expansion joint 21

22 5. MATERIALS TOOLS AND HARDWARE TOOLS AND SEALANTS Electric tin snips Metal cutting circular saw with fine tooth carbide blade Caulking gun Power drill / Screw gun Brick Guillotine (Chopper) Tape measure Chalk line Rubber mallet Pointing Gun Mortar paddle Grout bag Mortar scoop Mason s Soft Bristle Brush 22

23 NOTES 23

24 BENCHMARK Support BENCHMARK By Kingspan Columbus, OH, USA Modesto, CA, USA Caledon, ON, CA Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only and Kingspan Limited and its subsidiaries accept no liability in respect thereof.

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV

More information

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide Flushglaze 7500 For Steel Tube pplications and Horizontal Panels Façades Installation Guide September 2016 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal

More information

Installation Guide Wall Panels

Installation Guide Wall Panels Installation Guide Wall Panels Jointless or Dry-Stacked Installation (Read Prior to installation) The MStone system is a jointless / dry-stacked installation where panels and corners fit tightly together

More information

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Thank you for purchasing the Genesis Dura-Max Brick Panel system for your project. The system allows you to have the look

More information

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing

More information

Impression Graphic panels

Impression Graphic panels Impression Graphic panels Installation Guidelines 6003.I Rev. 02 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to

More information

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions Introduction: The ProVantage Glass Block Installation System is the easiest way to install Pittsburgh Corning Premiere

More information

KARRIER PANEL - BRICK

KARRIER PANEL - BRICK KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK

More information

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

DETAIL INSTRUCTION No. 1

DETAIL INSTRUCTION No. 1 BEFORE BEGINNING INSTALLATION, PLEASE READ THROUGH ALL INSTRUCTIONS. Uncrate shipment and check against packing list to insure all materials are included before beginning installation. If any discrepencies

More information

Installation Guidelines

Installation Guidelines Installation Guidelines Exteria Building Products provides these instructions as general guidelines only. Exteria Building Products neither installs siding nor has any control over any installation. The

More information

Exterior System installation instructions

Exterior System installation instructions Exterior System installation instructions 11/20/14 WPS ES-400 & 500 INSTALLATION INSTRUCTION. The WPS ES-400 & 500 systems Façade panels are designed for use as an external wall cladding in conjunction

More information

Container Installation Guide

Container Installation Guide Container Insulation Container Installation Guide Panels and Inserts The InSoFast CX Container panel and the Inserts are designed to fit most shipping containers. Containers have three types of corrugations:

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier.

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier. www.quakerwindows.com www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines for all Quaker products with nail fins New

More information

Se incluyen las instrucciones en español

Se incluyen las instrucciones en español Page 1 of 16 Pittsburgh Corning Corporation Pittsburgh, PA 15239 1-800-624-2120 www.pittsburghcorning.com All trademarks and registered trademarks in this brochure are owned and protected by Pittsburgh

More information

Installing the Sno-free Panel Eave System for New Roofs

Installing the Sno-free Panel Eave System for New Roofs Installing the Sno-free Panel Eave System for New Roofs SFP CLEAT SFP BASE SFP EXTRUSION SFP TOP COVER Step # 1 Placing the Cleat Install Ice and Water Shield as per code to the edge of sheeting. Install

More information

Revision Date: April 01, Premier Vinyl Enclosure

Revision Date: April 01, Premier Vinyl Enclosure Premier Vinyl Enclosure www.urbanindustries.com 53 Urban Industries, Inc. 2008 Tools The following tools are recommended for the installation of the Premier Vinyl Enclosure and roof. 1 2 Level 1 4 Level

More information

YOW 250 T Window System

YOW 250 T Window System MegaTherm Glass Fiber With 6/6 Nylon Thermal Break YOW 250 T SYSTEM DESCRIPTION YOW 250 T PERFORMANCE FEATURES 2-1/2 Overall Depth MegaTherm Thermal Break Separate Interior/Exterior Finish Options Variations:

More information

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit FreeStyle Linear Drain with Full Mortar Bed Adapter Kit U.S. Patent No. 8,474,068 Patents Pending: Canada & EP Publication No. 2354339 Discard Linear Drain installation instructions and refer to these

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

Agenda. Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia

Agenda. Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia Decking & Fascia Agenda Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia 2 Chapter 7 Tools & Materials Tools for Decking Hammer Measuring Tape Chalk Line Speed Square Utility Knife Circular

More information

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation

More information

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com Page2 INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation

More information

Installation Guide Single-Hung, Picture & Shapes Non-Impact & Impact Resistant Florida Flange Windows

Installation Guide Single-Hung, Picture & Shapes Non-Impact & Impact Resistant Florida Flange Windows Non-Impact & Impact Resistant Florida Flange Windows americancraftsmanwindows.com Project Requirements: Read guide before starting installation. Read all warnings and cautions during installation. Check

More information

Thin Architectural Splitface Block Veneer Specification Guide

Thin Architectural Splitface Block Veneer Specification Guide Thin Architectural Splitface Veneer System with AccuTab Technology R Thin Architectural Splitface Block Veneer Specification Guide Section 04711: Manufactured Concrete Veneer Use this specification guide

More information

DuraLife Capped Composite Decking Installation Instructions

DuraLife Capped Composite Decking Installation Instructions DuraLife Capped Composite Decking Installation Instructions Planning the design of the deck is the beginning of a successful project. 1. Read the application instructions carefully before starting the

More information

Install & Maintenance Instructions

Install & Maintenance Instructions Arterra Installation Please read these instructions thoroughly prior to beginning the Arterra installation. Inspect all materials for damage or missing parts. If you discover damaged or missing materials,

More information

Classic and NB Tile Counter Batten and Batten

Classic and NB Tile Counter Batten and Batten Classic and NB Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation

More information

Container Installation Guide

Container Installation Guide Continuous Insulation Container Installation Guide Panels and InSerts The InSoFast CX Container panel and the InSerts are designed to fit most shipping containers. Containers have three types of corrugations:

More information

KWiK N EZ Rigid Track Silicone System

KWiK N EZ Rigid Track Silicone System Page 1 of 6 PITTSBURGH CORNING KWiK N EZ Rigid Track Silicone System ASSEMBLY INSTRUCTIONS Introduction The KWiK N EZ Rigid Track Silicone System is the easiest way to install Pittsburgh Corning Thinline

More information

PITTSBURGH CORNING ASSEMBLY INSTRUCTIONS. KWiK N EZ Rigid Track Silicone System for Thinline Series Glass Block

PITTSBURGH CORNING ASSEMBLY INSTRUCTIONS. KWiK N EZ Rigid Track Silicone System for Thinline Series Glass Block Page 1 of 6 PITTSBURGH CORNING KWiK N EZ Rigid Track Silicone System for Thinline Series Glass Block ASSEMBLY INSTRUCTIONS Introduction The KWiK N EZ Rigid Track Silicone System is the easiest way to install

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet Perimeter Installation Procedures Concrete Faced Insulated Perimeter Wall Panels Concrete Faced Insulated Perimeter Wall Panels are prefinished, one-step exterior insulating panels

More information

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples.

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples. SECTION 04812 (042012) MECHANICALLY ATTACHED BRICK PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Resysta Wall Cladding Installation Guidelines

Resysta Wall Cladding Installation Guidelines Resysta Wall Cladding Installation Guidelines NOTE: Proper planning of the wall cladding layout is essential for ease of installation of wall cladding boards and wall cladding components. Thoroughly read

More information

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Typical Details AcroWall-ES System Class PB Exterior Insulation and Finish System providing a primary moisture barrier 1. Typical AcroWall-ES System Application 2. Typical Aesthetic Reveal 3. Typical Window

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08

More information

ALLMET CONTINENTAL INSTALLATION GUIDE

ALLMET CONTINENTAL INSTALLATION GUIDE ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental

More information

INSTALLATION GUIDE.

INSTALLATION GUIDE. INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten

More information

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation

More information

Installation Guidelines for Sealing PTAC Sleeves

Installation Guidelines for Sealing PTAC Sleeves www.quakerwindows.com www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines for Sealing PTAC Sleeves Read these instructions

More information

Installation Guide. Rain Screen Panel System

Installation Guide. Rain Screen Panel System Installation Guide Rain Screen Panel System Main Office 6860 South Abbott Road Orchard Park, New York 14127 tel 716.649.7490 toll free 1.888.214.3655 www.bostonvalley.com General Inquiries info@bostonvalley.com

More information

STORAGE AND TRANSPORTION

STORAGE AND TRANSPORTION Content 1. General & Notes 2. Substrate Processing 3. Panel Layout 4. Tools 5. Screws 6. Installation instructions 7. Cleaning 8. FAQS 8. MSDS General & Notes In comparison to natural or cast stone, Questone

More information

Installation Manual. Foundations. Version 2

Installation Manual. Foundations. Version 2 Installation Manual Foundations Version 2 Contents Overview...1 Planning the Job... 2 Introducing DMX FlexSheet...2 Supplies Required...3 Tools Required...4 Preparing the Site...4 Where to Start?...5 Installing

More information

BENCHMARK Evolution Axis

BENCHMARK Evolution Axis Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL

More information

Rectangular Area: 15 x 10 = 150 sq ft Triangular Area: 15 x 5 x ½ = 38 sq ft

Rectangular Area: 15 x 10 = 150 sq ft Triangular Area: 15 x 5 x ½ = 38 sq ft Thanks for allowing Impressions in Stone to fulfill your manufactured stone requirements! With proper installation in accordance with all local Building Code specifications, your stone surface should provide

More information

SUPERIOR ROOF SYSTEMS

SUPERIOR ROOF SYSTEMS SUPERIOR ROOF SYSTEMS S U P E R I O R M E T A L P R O D U C T S C O M P A N Y, I N C. Installation instructions & parts list DESCRIPTION CATALOG # 1. Tek Screw #14 x 4 7725 2. Dow 999-A Silicone 7679 3.

More information

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions Assembly Manual 6x5 PATENTS ARE PENDING Building Dimensions Approximate Size Storage Area Exterior Dimensions Interior Dimensions Roof Edge to Roof Edge Wall to Wall Sq. Ft. Cu. Ft. Width Depth Height

More information

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS GUIDE FOR TIMBER AND CONCRETE FLOORS EDITION: APRIL 2016 IMPORTANT: This guide is for the installation of a Step Up shower base on a timber or concrete floor. If you require a walk in (flush with floor)

More information

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge Assembly Manual 8x5 PATENTS ARE PENDING Approximate Size 7980303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth

More information

rout & return INSTALLATION GUIDE

rout & return INSTALLATION GUIDE rout & return INSTALLATION GUIDE Effective October 2016 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Handling and Maintenance of Omega-Lite Panels 1 System Limitations and Pre-Installation

More information

Pittsburgh Corning Glass Block Shower System Mortar Installation Standard Fit Shower Instructions

Pittsburgh Corning Glass Block Shower System Mortar Installation Standard Fit Shower Instructions 1. Shower Base and Wall Preparation 1.1 After installation of the shower base, line base with paper or cardboard to protect during installation of the glass blocks. Measure 2 ½ inches out from the inside

More information

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars SECTION 04850 (04 40 00) MSI PRECAST STONE VENEER SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. MSI Precast Stone Veneer for exterior and interior vertical surfaces. 1.2 RELATED SECTIONS Specifier Notes:

More information

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM

More information

BARREL VAULT Tile Counter Batten and Batten Installation Guide

BARREL VAULT Tile Counter Batten and Batten Installation Guide BARREL VAULT Tile Counter Batten and Batten Installation Guide www.boral.com Page2 BARREL VAULT Tile Actual Size= 43 13/16 x 15 5/8 Exposure= 43 1/4 x 14 Weight= 5.4lbs. per panel Panels per square (100

More information

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth

More information

Assembly Instruction. wedi Fundo Primo Shower System

Assembly Instruction. wedi Fundo Primo Shower System Assembly Instruction wedi Fundo Primo Shower System Assembly Instructions wedi Fundo wedi Fundo Shower System-Primo Overview & General Product Description of the wedi Fundo Shower Systems All wedi Waterproof

More information

200 / 300 SERIES PANELS COLD STORAGE

200 / 300 SERIES PANELS COLD STORAGE CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES

More information

A-ONE Insulated Forms Installation Manual

A-ONE Insulated Forms Installation Manual A-ONE Insulated Forms Installation Manual Rockford, MN www.aoneform.com www.diversifoam.com info@diversifoam.com A-ONE Manual 180426.docx Disclaimer Notice The information in the A-ONE Insulated Forms

More information

WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS

WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS EDITION: APRIL 2016 IMPORTANT: If you require a Walk In shower base for timber floors, please go to our support page at www.hydroblok.com.au IMPORTANT:

More information

Window Installation Instructions Hung Window Systems with Receptor Pan

Window Installation Instructions Hung Window Systems with Receptor Pan STANDARD PROCEDURE No. I-110 Window Installation Instructions Hung Window Systems with Receptor Pan Examined, Accepted and Approved By: D Ray VanNess Title: President SUBJECT: Window Installation Instructions

More information

1 PVC or ABS drain with strainer

1 PVC or ABS drain with strainer Patents Pending ProBase II Single-Slope Shower Base and Kit CONTENTS 1. General Information...1 2. Materials...1 3. Planning...2 4. Preparation...3 5. Layout...3 6. Install Base and Shims...4 7. Install

More information

INSTRUCTIONS AND GUIDELINES

INSTRUCTIONS AND GUIDELINES INSTRUCTIONS AND GUIDELINES NOISEBLOCK TM MODULAR PANEL SYSTEMS ENCLOSURES & PRESSURIZED PLENUMS PLANNING HINTS & NOTES: 1. Review the Kinetics Noise Control submittal and installation drawings and bill

More information

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER PART 1 - GENERAL 1.01 SUMMARY SECTION 07 65 00 FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER A. Section includes through wall masonry flashing system components for installation over sheathing where spray

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT SECTION 04110 MORTAR AND MASONRY GROUT PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. In the absence of other information, the methods and recommendations of the National Concrete Masonry Association

More information

PART 1-SAWN THIN VENEER GENERAL

PART 1-SAWN THIN VENEER GENERAL PART 1-SAWN THIN VENEER GENERAL WORK INCLUDED: All labor and material for the furnishing and installing of exterior or interior stone building veneer. RELATED WORK: Masonry Contractor shall include building

More information

Duracast Pressure Plate Installation Instructions

Duracast Pressure Plate Installation Instructions July 2015 EFCO CORPORATION 7/2015 PART NO. YW45 1 TABLE OF CONTENTS SECTION S-5600 / S-5900 DURACAST PRESSURE PLATE PAGE I. General Notes and Guidelines. 3-4 II. Glazing Preparation & Installation... 5

More information

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. RobinsonBrick.com

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. RobinsonBrick.com OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide RobinsonBrick.com OLD BRICK ORIGINALS THIN BRICK VENEER Page 2 INTRODUCTION Check local building codes for proper installation guidelines

More information

Designwall 2000/4000. Façades Installation Guide

Designwall 2000/4000. Façades Installation Guide Designwall 2000/4000 Façades Installation Guide July 2017 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels and building envelope solutions. Insulated

More information

Commercial Flashing Details

Commercial Flashing Details This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from

More information

DRY SEAL INSTALLATION GUIDE

DRY SEAL INSTALLATION GUIDE DRY SEAL INSTALLATION GUIDE Effective September 2015 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Handling and Maintenance of Omega-Lite Panels 1 System Limitations and Pre-Installation

More information

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1 16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

ALPINE PATIO COVER INSTALLATION INSTRUCTIONS

ALPINE PATIO COVER INSTALLATION INSTRUCTIONS ALPINE PATIO COVER INSTALLATION INSTRUCTIONS Contact us at: 1-800-851-0865 or www.americana.com Before You Begin: Consult your local building department for any required permits You may be required to

More information

OZARK PATIO COVER INSTALLATION INSTRUCTIONS

OZARK PATIO COVER INSTALLATION INSTRUCTIONS OZARK PATIO COVER INSTALLATION INSTRUCTIONS Contact us at: 1-800-851-0865 or www.americana.com Before You Begin: Consult your local building department for any required permits You may be required to obtain

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

Assembly Instruction wedi Fundo Floor element

Assembly Instruction wedi Fundo Floor element Assembly Instruction wedi Fundo Floor element Assembly Instructions wedi Fundo Legend A Caulking nut B Rubber caulking gasket C Drain body D wedi sealant E Rubber gasket F Fiber gasket G Locking nut A

More information

Assembly Instruction. wedi Fundo Primo Steam Shower System

Assembly Instruction. wedi Fundo Primo Steam Shower System Assembly Instruction wedi Fundo Primo Steam Shower System Assembly Instructions wedi Fundo wedi Fundo Steam Shower System Residential and Commercial Use Whether installed in a steam room with commercial

More information

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products 5-Year Warranty Proudly Made in the U.S.A. Wayfinding Products Proudly Made in the U.S.A. Directional Bar Tile surface mount or cast-in-place replaceable (wet-set) Bar Tile and Guide Tile units shall be

More information

WEIGHT PER PIECE (LBS.)

WEIGHT PER PIECE (LBS.) PRODUCT DESCRIPTION DATA SHEET 04 73 19-US BASIC USE ProGUARD DP is intended to be installed over sheathing and waterproofing over steel or wood studs or over concrete masonry units or poured concrete

More information

FORMWORK 66 x 40 x 24 Lithic Freestanding or Alcove Box Bathtub Installation Guidelines. STYLE No. CAUTION: BATHTUB IS EXTREMELY HEAVY

FORMWORK 66 x 40 x 24 Lithic Freestanding or Alcove Box Bathtub Installation Guidelines. STYLE No. CAUTION: BATHTUB IS EXTREMELY HEAVY STYLE No. STYLE No. FMBT6L (With Left Drain) FMBT6R (With Right Drain) CAUTION: BATHTUB IS EXTREMELY HEAVY PACKAGED WEIGHT... 1200 LBS [544.3 KG] DRY WEIGHT... 1050 LBS [476.3 KG] FILLED WEIGHT... 1750

More information

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System 0 00/NGC NATIONAL GYPSUM COMPANY -Hour Wall System The -Hour is a -hour fire wall consisting of in. (0. mm) light-gauge steel H-Studs that secure two layers of in. (. mm) shaftliner panels friction-fit

More information

BioPrism Solid Surface

BioPrism Solid Surface Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.

More information

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.

More information

Chapter 13. Ceiling Sheetrock

Chapter 13. Ceiling Sheetrock Chapter 13. Ceiling Sheetrock 13.1 PREPARATION 13.2 PLANNING 13.3 GENERAL INSTALLATION RULES 13.4 INSTALLING CEILING SHEETROCK 13.5 ASSEMBLING SCUTTLE BOX COVER 13.6 FINISHING SCUTTLE BOX COVER Tools needed

More information

Chapter 25: Sliding Door Opening Framing

Chapter 25: Sliding Door Opening Framing Chapter 25: Sliding Door Opening Framing Most Common Mistakes: 1. Locating header at incorrect height. 2. Failure to install siding backing. 3. Track board not installed, at wrong height, or cut to incorrect

More information

Product and System Specifications DuPont Flashing Systems

Product and System Specifications DuPont Flashing Systems DuPont Building Innovations March 2007 4417 Lancaster Pike Chestnut Run Plaza 721 Wilmington, DE 19805 1-800-448-9835 www.construction.tyvek.com Product and System Specifications DuPont Flashing Systems

More information

Substation #9 Instructions for Assembly of the HO scale kit. v1.1

Substation #9 Instructions for Assembly of the HO scale kit. v1.1 Substation #9 Instructions for Assembly of the HO scale kit. v1.1 Kit Contents: 26 each.090" Acrylic parts 2 each.060" Acrylic parts 1 each.060" Acrylic parts sheet 1 each.020" Adhesive backed styrene

More information

Shower Pan Extension Installation Guide

Shower Pan Extension Installation Guide Shower Pan Extension Installation Guide Before Installing your HYDRO-BLOK Shower System Perform a final floor and wall measurement check to ensure all walls are square and make any adjustments required

More information

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS Window Fastening Although all possible measures have been taken to insure the accuracy of the material presented, WIXSYS, and the author are not

More information

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System -Hour Wall System The -hour Wall System is a -hour fire wall consisting of two layers of in. (. mm) shaftliner panels friction-fit between in. (0. mm) light-gauge steel H-Studs and a layer of /" Fire-Shield

More information

0331 Brick and block construction

0331 Brick and block construction 0331 BRICK AND BLOCK CONSTRUCTION 1 GENERAL 1.1 STANDARDS Materials and construction: To AS 4773.1 and AS 4773.2. 2 PRODUCTS 2.1 DURABILITY Exposure environment: [complete/delete] Exposure locations: To

More information

TYPICAL ROOF CONDITION LAYOUT

TYPICAL ROOF CONDITION LAYOUT FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/

More information

INSTALLATION MANUAL KOCH

INSTALLATION MANUAL KOCH INSTALLATION MANUAL KOCH TECHNICAL SYSTEMS GROUP PRE-FAB ACOUSTICAL/THERMAL PANELS AND ENCLOSURES GEORGE KOCH SONS, LLC TECHNICAL SYSTEMS GROUP 10 South Eleventh Avenue Evansville, Indiana 47744 812-465-9600

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05

More information

OmniFlex 300 Plus Installation Instructions

OmniFlex 300 Plus Installation Instructions OmniFlex 300 Plus Installation Instructions IMPORTANT PortaFab advises a thorough reading of these instructions before beginning installation. INTRODUCTION Instructions should be read thoroughly and cross-referenced

More information

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION This Technical Notes contains the guide specifications in CSI format for Part III

More information

SECTION STAINLESS STEEL WALL PANELS

SECTION STAINLESS STEEL WALL PANELS SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.

More information