ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year.

Size: px
Start display at page:

Download "ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year."

Transcription

1 Reissued November, 008 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. Business/Regional Office 60 Workman Mill Road, Whittier, California 9060 (6) Regional Office 900 Montclair Road, Suite A, Birmingham, Alabama (0) Regional Office 0 West Flossmoor Road, Country Club Hills, Illinois 6078 (708) DIVISION: 0 CONCRETE Section: 0 Concrete Anchoring DIVISION: 0 MASONRY Section: 008 Masonry Anchoring DIVISION: 0 METALS Section: 0090 Metal Fastenings DIVISION: 06 WOOD AND PLASTIC Section: Wood and Plastic Fastenings REPORT HOLDER: HILTI, INC. 00 SOUTH ND EAST AVENUE TULSA, OKLAHOMA 76 (800) HNATechnicalServices@hilti.com EVALUATION SUBJECT: HILTI LOW-VELOCITY X-U AND X-U UNIVERSAL POWDER DRIVEN FASTENERS.0 EVALUATION SCOPE Compliance with the following codes: 006 International Building Code (006 IBC) 006 International Residential Code (006 IRC) 00 International Building Code (00 IBC)* 00 International Residential Code (00 IRC)* 000 International Building Code (000 IBC)* 000 International Residential Code (000 IRC)* 997 Uniform Building Code (UBC)* *Codes indicated with an asterisk are addressed in Section 8.0. Property evaluated: Structural.0 USES. General: The Hilti X-U fasteners are used to attach wood, light gage steel, and other building elements to normal-weight and structural sand-lightweight concrete, steel decks with structural sand-lightweight concrete fill, concrete masonry and steel base materials. The Hilti X-U fasteners are used to attach light gage steel and other building elements to steel. The fasteners are alternatives to the cast-in-place anchors described in IBC Sections 9 and 9 for placement in concrete; the embedded anchors described in Section.. of ACI 0 (which is referenced in IBC Section 07) for placement in grouted masonry; and the bolts used to attach materials to steel, described in IBC Section 0.. The fasteners may be used where an engineered design is submitted in accordance with IRC Section R0.... Horizontal Diaphragms: The Hilti X-U fasteners may be used as alternates to 0d common nails for fastening wood structural panel diaphragms to structural steel members..0. Fasteners:.. X-U: The X-U fasteners are powder driven fasteners made from hardened steel complying with the manufacturer s quality documentation, austempered to a Rockwell C nominal hardness of 8 and zinc-plated in accordance with ASTM B 6 SC, Type III. The fasteners have a shank diameter of 0.7 inch (.0 mm), a head diameter of 0. inch (8. mm) and a knurled tip, and come in lengths ranging from 0.6 inch to.8 inches (6 to 7 mm). See Figure for the fastener configuration... X-U : The X-U fasteners are powder driven fasteners made from hardened steel complying with the manufacturer s quality documentation, austempered to a Rockwell C nominal hardness of 9 and zinc plated in accordance with ASTM B 6 SC, Type III. The fasteners have a shank diameter of 0. inch (.7 mm), a head diameter of 0. inch (8. mm) and a shank length of 0.6 inch (6 mm). See Figure for the fastener configuration.. Concrete: Normal-weight and structural sand-lightweight concrete must conform to IBC Section 90 or IRC Section R0., as applicable. The minimum concrete compressive strength at the time of fastener installation is noted in the tables of this report.. Masonry: Masonry must be comprised of normal-weight concrete masonry units (CMUs) complying with ASTM C 90 and Type S mortar complying with IBC Section 0.8 or IRC Section R607, as applicable. The CMUs must have a minimum nominal width of 8 inches (0 mm). Where specified in Table 6 of this report, masonry construction must be fully grouted and must have minimum prism strength, f m, of,00 psi (0. MPa) at the time of fastener installation. Grout must comply with IBC Section 0. or IRC Section R609.., as applicable. are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 008 Page of 9

2 Page of 9. Steel Substrates: Structural steel must comply with the minimum requirements of ASTM A 6 and have a thickness as shown in Table. Steel deck properties and configurations are to be as described in the footnotes to Table, and Figures 6 through 8, of this report.. Wood Structural Panel Horizontal Diaphragms:.. Wood Structural Panel: Wood structural panels must have a minimum thickness of / inch (.9 mm) and must comply with the requirements of IBC Section Structural Steel Supports: Structural steel framing members supporting the wood structural panel diaphragm must comply with the minimum requirements of ASTM A 6 and have a minimum thickness of / 6 inch (.8 mm)..0 DESIGN AND INSTALLATION. Design:.. General: The allowable shear and tension service loads for the X-U and X-U fasteners installed in steel, and the X-U fasteners installed in normal-weight concrete, structural sand-lightweight concrete, structural sandlightweight concrete filled steel deck and masonry can be found in Tables through 6 as summarized in Table. The stress increases and load reductions described in Section 60. of the IBC are not allowed for wind loads acting alone or when combined with gravity loads. No increase is allowed for vertical loads acting Except for fasteners used with architectural, electrical and mechanical components as described in Section.. of ASCE/SEI 7, and fasteners used as described in Sections.. and..7, use of fasteners to resist earthquake loads is outside the scope of this report. Allowable loads for fasteners subjected to combined shear and tension forces are determined by the following formula: (P s /P t) + (V s /V t ) where: P s = Applied service tension load, pounds (N). P t = Allowable service tension load, pounds (N). V s = Applied service shear load, pounds (N). V t = Allowable service shear load, pounds (N)... Wood to Steel, Concrete, or Masonry: Reference lateral design values for fasteners determined in accordance with Part of ANSI/AF&PA NDS are applicable to Hilti fasteners of equal or greater diameters. The wood element must be considered to be the side member. The fastener bending yield strength is allowed to be taken as the value noted in the NDS based on the fastener diameter... Wood Structural Deck Diaphragms: When the X- U fastener is used to fasten wood structural panels to steel members, the fastener is recognized as equivalent to a 0d common nail. Diaphragm design, including fastener spacing, diaphragm capacity and diaphragm deflection, must comply with IBC Sections 0. and Installation:.. General: The X-U and X-U fasteners must be installed in accordance with this report and the manufacturer s published installation instructions. A copy of these instructions must be available on the jobsite at all times during installation. Installation must be limited to dry, interior locations. Fastener placement requires the use of a low-velocity powder-actuated tool in accordance with Hilti recommendations. Installers must be certified by Hilti and have a current, Hilti-issued, operator s license... Fastening to Steel: When installed in steel, minimum spacing between fasteners must be inch (. mm) and minimum edge distance must be / inch (.7 mm)... Fastening to Concrete: Fasteners are to be driven into the concrete after the concrete attains the specified concrete strength. Minimum spacing between fasteners must be inches (0 mm) and minimum edge distance must be inches (76 mm). Unless noted otherwise in this report, concrete thickness must be a minimum of three times the penetration depth of the fastener... DX-Kwik System: Installation of the X-U fastener into normal-weight concrete, using the Hilti DX-Kwik system as an alternate procedure, requires the drilling of a pilot hole using a drill bit (TX-C /) supplied by Hilti, Inc., prior to the installation of the fastener with the powderactuated tool. DX- Kwik installation procedures are shown in Figure... Fastening to Structural Sand-lightweight Concrete Filled Steel Deck: Installation in structural sandlightweight concrete filled steel deck must comply with Figures 6 through 8. Minimum distances from fastener centerline to rolled deck flute edges must be as depicted in Figures 6 through Fastening to Masonry: Fasteners must be driven into the masonry after the mortar and grout materials have attained the specified strength. Fasteners must be located in accordance with Table Wood Structural Panel Diaphragms: The wood structural panels must be fastened to the steel members at the spacing determined by the design. When used, the optional steel strap is placed on top of the panels and the fasteners are driven through the strap and panel into the supporting steel member. The minimum distance from the centerline of the fasteners to the edge of the panel is / 8 inch (9. mm). Fastener penetration and distance to the edge of the supporting steel member must be as described in Section... See Figure 0 for a typical installation detail showing one row of fasteners. Multiple rows of fasteners may be installed if required by the design. The remainder of the diaphragm must be constructed in accordance with the code..0 CONDITIONS OF USE The Hilti X-U and X-U fasteners described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section.0 of this report, subject to the following conditions:. The fasteners are manufactured and identified in accordance with this report.. Fastener installation complies with this report and the Hilti, Inc., instructions. In the event of conflict between this report and Hilti, Inc., published instructions, this report governs.. Allowable tension and shear values are as noted in Tables through 6. The stress increases and load reductions described in Section 60. of the IBC are not allowed for wind loads acting alone or when combined with gravity loads. No increase is allowed for vertical loads acting. Calculations demonstrating that the applied loads are less than the allowable loads described in this report

3 Page of 9 must be submitted to the code official for approval. The calculations are to be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is constructed.. Except for fasteners used with architectural, electrical and mechanical components as described in Section.. of ASCE/SEI 7, and fasteners used to fasten wood structural panel diaphragms to steel members as described in Sections.. and..7, use of fasteners to resist earthquake loads is outside the scope of this report..6 The use of fasteners is limited to installation in uncracked concrete or masonry. Cracking occurs when f t > f r due to service loads or deformations..7 Use of fasteners is limited to dry, interior locations..8 Use of fasteners in contact with preservative-treated or fire-retardant-treated wood is not permitted..9 Installers must be certified by Hilti and have a current, Hilti-issued, operator s license. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Fasteners Power-driven into Concrete, Steel and Masonry Elements (AC70), dated October IDENTIFICATION Each package of fasteners is labeled with the fastener type, size, manufacturer s name (Hilti) and evaluation report number (). An H, for Hilti, is imprinted on the head of the fastener as shown in Figures and. 8.0 OTHER CODES 8. Scope: In addition to the 006 IBC and 006 IRC, the products in this report were evaluated for compliance with the requirements of the following codes: 00 International Building Code (00 IBC) 00 International Residential Code (00 IRC) 000 International Building Code (000 IBC) 000 International Residential Code (000 IRC) 997 Uniform Building Code (UBC) 8. Uses: 8.. General: The Hilti X-U and X-U fasteners are used to connect materials as described in Section.0. The fasteners are alternatives to the cast-in-place anchors described in 00 and 000 IBC Sections 9 and 9 and UBC Section 9. for placement in concrete; the embedded anchors described in Section. of ACI 0 (which is referenced in 00 and 000 IBC Section 07) and UBC Section 07.. for placement in grouted masonry; and the bolts used to attach materials to steel, described in 00 IBC Section 0., 000 IBC Section 09, and UBC Section 0.. The fasteners may be used where an engineered design is submitted in accordance with 00 IRC Section R0.. or 000 IRC Section R0.., as applicable. 8.. Horizontal Diaphragms: See Section.. 8. Description: 8.. Fasteners: See Section Concrete: See Section.. Under the UBC, concrete must conform to Section Masonry: See Section.. Under the 00 and 000 IBC, mortar and grout must comply with Sections 0.7 and 0.0, respectively. Under the UBC, mortar and grout must comply with Sections 0. and 0., respectively. 8.. Steel Substrates: See Section Wood Structural Panel Diaphragms: See Section.. Under the UBC, the wood structural panel must comply with Section Design and Installation: 8.. Design: 8... General: See Section... The stress increases described in Section 6.. of the UBC are not allowed for wind loads acting alone or when combined with gravity loads. Except for fasteners used with architectural, electrical and mechanical components as described in Section 9.6. of ASCE/SEI 7-0 (00 IBC and IRC) or Section 9.6. of ASCE/SEI 7-98 (000 IBC and IRC), and fasteners used as described in Sections.. and..7, use of fasteners to resist earthquake loads is outside the scope of this report Wood to Steel, Concrete, or Masonry: See Section... Reference lateral design values for fasteners determined in accordance with Part of ANSI/AF&PA NDS (00 IBC and IRC), Part of ANSI/AF&PA NDS (000 IBC and IRC), or Section 8. of the UBC, as applicable, are applicable to Hilti fasteners of equal or greater diameters Wood Structural Deck Diaphragms: See Section... Under the UBC, diaphragm design must comply with UBC Section.. and Section. of UBC Standard -, as applicable. 8.. Installation: See Section.. 8. Conditions of Use: See Section.0, and the following: 8.. Allowable tension and shear values are as noted in Tables through 6. The stress increases and load reductions described in Section 60. of the 006 and 00 IBC, and the stress increases described in Section 6.. of the UBC, are not allowed for wind loads acting alone or when combined with gravity loads. No increase is allowed for vertical loads acting 8.. Except for fasteners used with architectural, electrical and mechanical components as described in Section 9.6. of ASCE/SEI 7-0 (00 IBC and IRC) or Section 9.6. of ASCE/SEI 7-98 (000 IBC and IRC), and fasteners used as described in Sections.. and..7, use of fasteners to resist earthquake loads is outside the scope of this report. 8.6 Evidence Submitted: See Section Identification: See Section 7.0.

4 Page of 9 FIGURE CHILTI X-U FASTENER FIGURE CHILTI X-U FASTENER TABLE APPLICATION S BASE MATERIAL POWDER-ACTUATED INSTALLATION METHOD LOAD DATA FASTENER Steel X-U and X-U Fasteners Standard Table Normal-Weight Concrete X-U Fastener Standard Table DX KWIK Table Structural Sand-lightweight Concrete X-U Fastener Standard -inch Deep Composite Floor Deck X-U Fastener Standard Table / -inch Deep Composite Floor Deck X-U Fastener Standard Hollow Concrete Masonry Units X-U Fastener Standard Grout-Filled Concrete Masonry Units X-U Fastener Standard Table 6 FIGURE CSTANDARD INSTALLATION PROCEDURES FOR X-U AND X-U FASTENERS IN STEEL

5 Page of 9 FIGURE CSTANDARD INSTALLATION PROCEDURES FOR X-U FASTENERS IN CONCRETE TABLE ALLOWABLE SERVICE LOADS FOR FASTENERS DRIVEN INTO STEEL,,6, 7 (lbf) FASTENER FASTENER SHANK STEEL THICKNESS / 6 / / 8 / > / Shear Shear Shear Shear Shear 0 7 X-U X-U For SI: inch =. mm, lbf =. N. The tabulated allowable load values are for the fasteners only. Wood or steel members connected to the steel substrate must be investigated in accordance with accepted design criteria. The fasteners must be driven to where the point of the fastener penetrates through the steel base material, unless otherwise noted. Based upon minimum point penetration of / 8 -inch. Based upon minimum point penetration of / -inch. Based upon minimum point penetration of / -inch. 6 7 The stress increases and load reductions described in Section 60. of the IBC and the stress increases described in Section 6.. of TABLE ALLOWABLE SERVICE LOADS FOR FASTENERS DRIVEN INTO NORMAL-WEIGHT CONCRETE,,,, (lbf) FASTENER FASTENER SHANK X-U 0.7 MINIMUM EMBEDMENT CONCRETE COMPRESSIVE STRENGTH 000 psi 000 psi 6000 psi Shear Shear Shear / / / For SI: inch =. mm, lbf =. N, psi = 689 Pa. The tabulated allowable load values are for the fasteners only. Wood or steel members connected to the substrate must be investigated in accordance with accepted design criteria. The stress increases and load reductions described in Section 60. of the IBC and the stress increases described in Section 6.. of Fasteners must not be driven until the concrete has reached the designated minimum compressive strength. Concrete thickness must be a minimum of times the embedment depth of the fastener.

6 Page 6 of 9 FASTENER FASTENER TABLE ALLOWABLE SERVICE LOADS FOR FASTENERS DRIVEN INTO NORMAL-WEIGHT CONCRETE USING DX-KWIK,,,,,6 (lbf) SHANK MINIMUM EMBEDMENT CONCRETE COMPRESSIVE STRENGTH,000 psi 6,000 psi Shear Shear X-U 7 P8 w/ 0.7 / DX-Kwik For SI: inch =. mm, lbf =. N, psi = 689 Pa. X-U Fastener is installed using the DX-Kwik drilled pilot hole installation procedure described in Section.. and shown in Figure. The tabulated allowable load values are for the fasteners only. Wood or steel members connected to the concrete substrate must be investigated in accordance with accepted design criteria. The stress increases and load reductions described in Section 60. of the IBC and the stress increases described in Section 6.. of Pilot holes must not be drilled until the concrete has reached the designated minimum compressive strength. 6 Concrete thickness must be a minimum of times the embedment depth of the fastener. FIGURE CDX KWIK INSTALLATION PROCEDURES

7 Page 7 of 9 FASTENER FASTENER TABLE ALLOWABLE SERVICE LOADS FOR FASTENERS DRIVEN INTO MINIMUM f c = 000 psi STRUCTURAL SAND-LIGHT WEIGHT CONCRETE,,,6 (lbf) SHANK X-U 0.7 MINIMUM EMBEDMENT Installed into Concrete 7 Shear Upper Flute FASTENER LOCATION Installed Through Metal Deck into Concrete, 8 -inch deep composite floor deck, Lower Flute Shear / -inch deep composite floor deck, Upper Flute Lower Flute Shear / / / For SI: inch =. mm, lbf =. N, psi = 689 Pa. The tabulated allowable load values are for the fasteners only. Wood or steel members connected to the substrate must be investigated in accordance with accepted design criteria. The steel deck profile for the -inch deep composite floor deck has a minimum thickness of 0.09 inch (0.9 mm) and a minimum F y of ksi. Lower and upper flute width must be a minimum of / inches. Figure shows the nominal flute dimensions, fastener locations, and load orientations for the deck profile. Structural sand-lightweight concrete fill above top of steel deck must be minimum / inches thick. The steel deck profile for the / -inch deep composite floor deck has a minimum thickness of 0.09 inch (0.9 mm) and a minimum F y of ksi. Lower flute and upper flute widths must be a minimum of / -inch and / -inch, respectively. This deck may also be inverted as shown in Figure 7. Figures 6 and 7 show the nominal flute dimensions, fastener locations, and load orientations for the deck profile. Structural sandlightweight concrete fill above top of steel deck must be minimum / inches thick. The stress increases and load reductions described in Section 60.. of the IBC and the stress increases described in Section 6.. of 6 Fasteners must not be driven until the concrete has reached the designated minimum compressive strength. 7 Concrete thickness must be a minimum of times the embedment depth of the fastener. 8 Minimum allowable spacing parallel to the deck flutes is. inches. FIGURE 6CHILTI FASTENER LOCATION IN -INCH-DEEP COMPOSITE FLOOR DECK, NORMAL DECK PROFILE ORIENTATION FIGURE 7CHILTI FASTENER LOCATION IN / -INCH-DEEP COMPOSITE FLOOR DECK, NORMAL DECK PROFILE ORIENTATION

8 Page 8 of 9 FIGURE 8CHILTI FASTENER LOCATION IN / -INCH-DEEP COMPOSITE FLOOR DECK, INVERTED DECK PROFILE ORIENTATION TABLE 6 ALLOWABLE SERVICE LOADS FOR FASTENERS DRIVEN INTO CONCRETE MASONRY UNITS,,,,9,0 (pounds) FASTENER FASTENER SHANK MINIMUM EMBEDMENT HOLLOW CMU GROUT-FILLED CMU Face Shell Mortar Joint, Face Shell, Top of Grouted Mortar Joint Cell 7 Shear Shear 6 Shear Shear 6 Shear 8 X-U The tabulated allowable load values are for the fastener into concrete masonry units only. Wood or steel members connected to the substrate must be investigated in accordance with accepted design criteria. The tabulated allowable load values are for fasteners installed in masonry conforming to the requirements of Section. of this report. No more than one low-velocity fastener may be installed in an individual concrete masonry unit cell. The fastener must be installed a minimum of inches from the edge of the wall. Fastener can be located in the face shell or mortar joint as shown in Figure 8 of this report. Fasteners must be installed a minimum of 8 inches from the end of the wall. Multiple fasteners in a bed joint must be spaced a minimum of 8 inches. 6 Shear load direction can be horizontal or vertical (bed joint or T-Joint) along the CMU wall plane. 7 Fastener located in center of grouted cell installed vertically. 8 Shear load can be in any direction in top of grouted cell application. 9 0 The stress increases and load reductions described in Section 60.. of the IBC and the stress increases described in Section 6.. of FIGURE 9CACCEPTANCE LOCATIONS (NONSHADED AREAS) FOR HILTI FASTENERS IN CMU WALLS

9 Page 9 of 9 FIGURE 0 WOOD STRUCTURAL PANEL DECK ATTACHMENT TO STEEL LEDGER WITH HILTI X-U UNIVERSAL POWDER DRIVEN FASTENER

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year. ESR- Reissued September, 00 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 0 Workman Mill Road, Whittier, California 900 #

More information

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015 0 ICC ES Report ICC ES (800) 42 6587 (562) 699 054 www.icc es.orgg 000 Most Widely Accepted and Trusted ESR 2269 Reissued 02/205 This report is subject to renewal 02/207. DIVISION: 0 00 00 CONCRETE SECTION:

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS GEORGE HOVAGUIMIAN CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-2269 Reissued 02/2017 Revised 11/2018 This report is subject to renewal 02/2019.

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2269 Reissued 02/2017 This report is subject to renewal 02/2019. DIVISION: 03 00

More information

where: P s = Applied service tension load, pounds (kg). P t V s V t

where: P s = Applied service tension load, pounds (kg). P t V s V t Æ Æ Æ Æ Æ Æ Æ Æ Æ ESR-1752 Most Widely Accepted and Trusted Page 2 of 7 3.1.7 X-S16P8TH: The X-S16P8TH fastener is a powder actuated fastener for installation into steel. It has a shank diameter of 0.145

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT PEDRO BIRBA VICE-PRESIDENT VAN AMBATIELOS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA MAYOR

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1663 Reissued 03/2017 This report is subject to renewal 03/2019. DIVISION: 03 00 00 CONCRETE

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT VAN AMBATIELOS VICE-PRESIDENT VICTOR H. CUEVAS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

*Corrected October 2005

*Corrected October 2005 ESR-1056* Reissued December 1, 2004 This report is subject to re-examination in two years. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 42-6587 (562) 699-054 www.icc-es.org ESR-1752 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 0 00 00

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3833 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 03 00

More information

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 42-6587 (562) 699-054 www.icc-es.org Most Widely Accepted and Trusted ESR-66 Reissued 0/207 Revised 2/208 This report is subject to renewal 0/209. DIVISION:

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS 0 ICC-ES Report ICC-ES (800) 42-6587 (562) 699-054 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-45 Reissued 06/206 This report is subject to renewal 06/207 DIVISION: 0 00 00CONCRETE SECTION:

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS GEORGE HOVAGUIMIAN CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2184 Reissued 06/2017 This report is subject to renewal 06/2019. DIVISION: 03 00

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS INTERIM PRESIDENT E. FELICIA BRANNON JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-CW CEILING WIRE FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED SUBSTITUTION: Use

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS SEPAND SAMZADEH CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code. LEGACY REPORT ER-2895 Reissued March 1, 2004 www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional Office 900 Montclair Road, Suite A, Birmingham,

More information

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3275 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 03 00

More information

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015.

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 4-6587 (56) 699-054 ESR-06 Reissued May, 0 This report is subject to renewal June, 05. A Subsidiary of the International Code Council DIVISION: 0 00 00 CONCRETE

More information

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2347 Reissued 12/2015 This report is subject to renewal 12/2017. DIVISION: 05 00 00 METALS SECTION:

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ESR 247 Reissued 2/207 This report is subject to renewal 2/209. DIVISION: 05 00 00 METALS

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588 0 ICC ES Report ICC ES (800) 4 687 (6) 699 04 www.icc es.org 000 Most Widely Accepted and Trusted ESR 06 Valid: 0/ to 0/6 DIVISION: 04 00 00 MASONRY SECTION: 04 0 9.6 MASONRY ANCHORS REPORT HOLDER: SIMPSON

More information

ESR ICC Evaluation Service, Inc. Issued March 1, 2006 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Issued March 1, 2006 This report is subject to re-examination in one year. ESR-1328 Issued March 1, 2006 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601

More information

FROM: PROPOSED SUBSTITUTION: Use HILTI X-U instead of fillet weld or arc spot puddle weld

FROM: PROPOSED SUBSTITUTION: Use HILTI X-U instead of fillet weld or arc spot puddle weld DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED SUBSTITUTION: Use

More information

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1530 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 03 00

More information

ESR ICC Evaluation Service, Inc. Reissued July 1, 2006 This report is subject to re-examination in two years.

ESR ICC Evaluation Service, Inc. Reissued July 1, 2006 This report is subject to re-examination in two years. ESR-1178 Reissued July 1, 2006 This report is subject to re-examination in two years. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1678 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 04 00 00 MASONRY

More information

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 2347 Reissued 12/2017 Revised 09/2018 This report is subject to renewal 12/2019.

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3056 Reissued 10/2015 This report is subject to renewal 10/2017. DIVISION: 04 00 00 MASONRY

More information

LEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER-5608*   Reissued February 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT ER-5608* Reissued February 1, 2004 www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional Office 900 Montclair Road, Suite A, Birmingham,

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 687 (6) 699 0 www.icc es.org ESR 8 Reissued 0/08 This report is subject to renewal 0/09. DIVISION: 0 00 00 MASONRY SECTION:

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286 0 ICC-ES Report ICC-ES (800) -687 (6) 6-0 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-678 Reissued 0/0 This report is subject to renewal 0/06 DIVISION: 0 00 00 MASONRY SECTION: 0 0.6 MASONRY

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 687 (62) 699 04 www.icc es.org ESR 06 Reissued 0/207 This report is subject to renewal 0/208. DIVISION: 04 00 00 MASONRY

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS SEPAND SAMZADEH CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR DEPARTMENT

More information

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year. ESR-1967 Reissued January 1, 2008 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

To: Firm: Project: Product Specified: Specified Location:

To: Firm: Project: Product Specified: Specified Location: Submittal Substitution Request To: Firm: Project: Product Specified: Specified Location: Attached information includes product description, installation instructions and technical data needed for review

More information

FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST

FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST DATE: PROJECT: TO: FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST SPECIFICATION TITLE: SECTION: PAGE: ARTICLE/PARAGRAPH: DESCRIPTION: DESIGN DETAIL NO.: PROPOSED

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2966 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 04 00

More information

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3009 Reissued 02/2018 This report is subject to renewal 02/2020. SECTION: 03 16 00

More information

Product Submittal/Substitution Request

Product Submittal/Substitution Request Product Submittal/Substitution Request TO: PROJECT: PROJECT LOCATION: SPECIFIED ITEM: Section Page Paragraph Description PRODUCT SUBMIT TAL / SUBSTITUTION REQUESTED: The attached submittal package includes

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 687 (6) 699 04 www.icc es.org ESR 78 Reissued 07/018 This report is subject to renewal 07/019. DIVISION: 04 00 00 MASONRY

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS GEORGE HOVAGUIMIAN CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2787 Reissued 05/2017 This report is subject to renewal 05/2019. DIVISION: 03 00

More information

ACCEPTANCE CRITERIA FOR FASTENERS POWER-DRIVEN INTO CONCRETE, STEEL AND MASONRY ELEMENTS PREFACE

ACCEPTANCE CRITERIA FOR FASTENERS POWER-DRIVEN INTO CONCRETE, STEEL AND MASONRY ELEMENTS PREFACE ICC EVALUATION SERVICE, INC. Evaluate P Inform P Protect ACCEPTANCE CRITERIA FOR FASTENERS POWER-DRIVEN INTO CONCRETE, STEEL AND MASONRY ELEMENTS AC70 Approved October 2006 Effective January 1, 2007 Previously

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2966 Reissued 12/2016 This report is subject to renewal 12/2017. DIVISION: 04 00 00 MASONRY

More information

CALIFORNIA ERIC GARCETTI MAYOR

CALIFORNIA ERIC GARCETTI MAYOR BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4042 Issued 07/2017 This report is subject to renewal 07/2018. DIVISION: 04 00 00

More information

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15. The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15. Please refer to the publication in its entirety for complete details on this product

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3196 Reissued 10/2018 This report is subject to renewal 10/2019. SECTION: 04 05 19.16

More information

*Corrected, April 2001

*Corrected, April 2001 LEGACY REPORT * Reissued January 1, 2001 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-3200 Reissued 12/2017 Revised 10/2018 This report is subject to renewal 12/2018 DIVISION:

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW BUILDEX 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW BUILDEX 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1671 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 04 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3200 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 04 00

More information

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 3105 Reissued 08/2017 Revised 10/2018 This report is subject to renewal 08/2019.

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3196 Reissued 10/2017 This report is subject to renewal 10/2018. SECTION: 04 05 19.16

More information

LEGACY REPORT DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

LEGACY REPORT DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC-ES Legacy Report 21-86.01 ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 06 00 00 WOOD,

More information

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2328 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 03 00

More information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued January 1, 2004 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 587 (52) 99 0543 www.icc es.org ESR 393 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 04 00 00 MASONRY

More information

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 43 6587 (56) 699 0543 www.icc es.org ESR 3754 Reissued 09/07 This report is subject to renewal 09/09. DIVISION: 03 00 00 CONCRETE

More information

ICC-ES Evaluation Report. ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

ICC-ES Evaluation Report. ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015. A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3071 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 06 00

More information

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3145 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 05 00 00 METALS SECTION:

More information

LEGACY REPORT REPORT HOLDER: ITW RAMSET EVALUATION SUBJECT:

LEGACY REPORT REPORT HOLDER: ITW RAMSET EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Legacy Report ICC ES 000 (800) 4 6587 (56) 699 054 www.icc es.org ER 580 Reissued 07/08 This report is subject to renewal 07/0. DIVISION: 05 00 00 METALS SECTION:

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3531 Reissued 04/2018 This report is subject to renewal 04/2019. DIVISION: 06 00

More information

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC.

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 43 6587 (56) 699 0543 www.icc es.org ESR 97 Reissued /7 This report is subject to renewal /8. DIVISION: 05 00 00 METALS SECTION:

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-4143 Issued 01/2018 This report is subject to renewal 01/2019. DIVISION: 04 00 00

More information

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years.

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years. ICC-ES Evaluation Report ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

Trusted ICC ES SECTION: Conformity! Look. Evaluation. ICC-ES Evaluation

Trusted ICC ES SECTION: Conformity! Look. Evaluation. ICC-ES Evaluation 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg ESR 3635 Reissued 04/2016 This report is subject to renewal 04/2018. DIVISION: 03 00

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS SECTION: PRECAST STRUCTURAL CONCRETE SECTION: SITE CAST CONCRETE

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS SECTION: PRECAST STRUCTURAL CONCRETE SECTION: SITE CAST CONCRETE 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2873 Issued 09/2017 This report is subject to renewal 09/2018. DIVISION: 03 00 00

More information

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1271 Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 05 00 00 METALS SECTION:

More information

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE ICC EVALUATION SERVICE, INC. Evaluate P Inform P Protect ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) AC191 Approved May 2008 Effective June 1, 2008 Previously approved February 2008, October 2007,

More information

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code LEGACY REPORT ER-4203 Reissued June 1, 2004 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office #

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ESR 299 Reissued 01/2019 This report is subject to renewal 01/2021. DIVISION: 06 00 00

More information

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry TITEN HD Heavy Duty Screw Anchor for & Masonry The Titen HD is a patented, high-strength screw anchor for concrete and masonry. The self-undercutting, non-expansion characteristics of the Titen HD makes

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS MARSHA L. BROWN PRESIDENT PEDRO BIRBA VICE-PRESIDENT VAN AMBATIELOS HELENA JUBANY ELENORE A. WILLIAMS CITY OF LOS ANGELES CALIFORNIA ANTONIO R. VILLARAIGOSA MAYOR

More information

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal May 1, 2015

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal May 1, 2015 [Type text] ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1958 Reissued March 2014 This report is subject to renewal May 1, 2015 A Subsidiary of the International Code Council

More information

DIVISION: WOOD, PLASTICS, AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS, AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2553 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 06 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-2648 Reissued 06/2018 Revised 10/24/2018 This report is subject to renewal 06/2020.

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3251 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 03 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC SOUTH 122 ND EAST AVENUE TULSA, OKLAHOMA 74146

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC SOUTH 122 ND EAST AVENUE TULSA, OKLAHOMA 74146 0 ICC ES Report ICC ES (800) 42 87 (2) 99 04 www.icc es.org 000 Most Widely Accepted and Trusted ESR 282 Valid: 08/4 to 08/ DIVISION: 04 00 00 MASONRY SECTION: 04 0 9. MASONRY ANCHORS REPORT HOLDER: HILTI,

More information

(800) (562) A Subsidiary of the International Code Council

(800) (562) A Subsidiary of the International Code Council ICC-ES Evaluation Report ESR-2089 Reissued September 2014 This report is subject to renewal September 2016. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

ESR-2555 Issued November 1, 2009 This report is subject to re-examination in two years.

ESR-2555 Issued November 1, 2009 This report is subject to re-examination in two years. ICC-ES Evaluation Rept ESR-2555 Issued November 1, 2009 This rept is subject to re-examination in two years. www.icc-es.g (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

ESR ICC Evaluation Service, Inc. Issued May 1, 2008 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Issued May 1, 2008 This report is subject to re-examination in one year. ESR-275 Issued May 1, 08 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 530 Workman Mill Road, Whittier, California 9001 #

More information

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2254 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 03 00

More information

STRENGTH AND DURABILITY OF THE INSTALLED STONE

STRENGTH AND DURABILITY OF THE INSTALLED STONE BEAUTY STRENGTH DURABILITY At Cast Natural Stone, we build each and every stone to stand up to the most brutal weather conditions. And with our manufacturing and headquarters located in Wisconsin, we know

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3342 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 04 00

More information

ICC-ES Evaluation Report Reissued January 1, 2012 This report is subject to renewal in one year.

ICC-ES Evaluation Report Reissued January 1, 2012 This report is subject to renewal in one year. ICC-ES Evaluation Report www.icc-es.org (800) 42-68 (62) 699-04 ESR-2 Reissued January, 202 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION: 04 00

More information

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3788 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 04 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4105 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 04 00 00

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2190 Reissued 06/2018 This report is subject to renewal 06/2020. DIVISION: 06 00

More information

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: MITEK USA, INC.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: MITEK USA, INC. 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1702 Reissued 06/2016 This report is subject to renewal 06/2018. DIVISION: 04 00

More information

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-409 Reissued June, 00 This report is subject to re-examination in one year. www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council DIVISION:

More information

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT: 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org Most Widely Accepted and Trusted ESR 1815 Reissued 10/2018 Revised 11/2018 This report is subject to renewal 10/2020.

More information

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2047 Reissued 07/207 This report is subject to renewal 07/209. DIVISION: 05 00 00

More information