CONSULTATION MEETING: Adoption of the 2015 edition of the Canadian Electrical Code

Size: px
Start display at page:

Download "CONSULTATION MEETING: Adoption of the 2015 edition of the Canadian Electrical Code"

Transcription

1 CONSULTATION MEETING: Adoption of the 2015 edition of the Canadian Electrical Code April 29, 2015 (10:00am-11:30am) Safe technical systems. Everywhere. Teleconference: #

2 Welcome! On the call today: Ted Gilbert, Electrical Safety Officer (presenter) Doug Kelly, Senior Policy Analyst Meryl Howell-Fellows, Stakeholder Engagement Programs Coordinator

3 Agenda 1. Introduction (10 min) Presented by Meryl Howell-Fellows 2. Major code changes (25 min) Presented by Ted Gilbert 3. Feedback, questions & answers (15 min) 4. Proposed BC amendments (15 min) Presented by Ted Gilbert 5. Feedback, questions & answers (25 min)

4 Introduction How to enter the teleconference: Call toll-free Enter the teleconference ID # Mute your phone line ** Please mute your phone line during the presentation sessions. There will be time at the end of each presentation for questions and answers.

5 Introduction How to use the webinar: Go to Click Join a Meeting, and enter OR Go to If you can see this, you re already logged in!

6 Introduction Why are we here today? The feedback process What will the feedback go towards? BC amendments are for: Consistency with provisions of the Safety Standards Act; Improvements to electrical safety; and, Clarification of ambiguous language which might create inconsistency and confusion by the Code users.

7 2015 CANADIAN ELECTRICAL CODE Numerous Editorial Changes Approximately 65 minor changes Approximately 35 significant changes 27 new Tables Table 6 conductors in raceways expanded Table 9 cross sectional areas of raceways expanded

8 Section 2, General Rules (1) Electrical equipment ratings (1) All electrical equipment marked with a short-circuit current rating or withstand rating shall have ratings sufficient for the voltage employed and for the fault current that is available at the terminals. ETAC has made a recommendation that a BC Amendment be adopted to delete this Rule as it is unenforceable Discussion and review later in presentation

9 Section Ampacity of wires and cables (see Appendix B) (23) Notwithstanding Rule 4-006, 3-wire 120/240 V and 120/208 V service conductors for single dwellings and feeder conductors supplying single dwelling units of row housing of apartment and similar buildings and terminating on equipment having a conductor termination temperature of not less than 75 C shall be permitted to be sized in accordance with Table 39.

10 4-004 (23) Ampacity of wires and cables (cont d)

11 4-004 (23) Ampacity of wires and cables (cont d) New method for determining service conductor sizing for single dwellings and feeder sizing for single dwelling units. Calculated load required before T39 can be used to select minimum conductor size. 5% rule already taken into account. Resolves conductor ampacity issues created by the 2012 edition of the CEC No BC amendment required

12 Section Voltage drop (see Appendices B and D) (1) The voltage drop in an installation shall be based on the connected load of the feeder or branch circuit if known; otherwise it shall be based on 80% of the rating of the overload or overcurrent device protecting the branch circuit or feeder, and not exceed (a) 3% in a feeder or branch circuit; and (b) 5% from the supply side of the consumer s service (or equivalent) to the point of utilization. (2) Notwithstanding Subrule (1), where overcurrent devices are selected in accordance with other Sections of this Code, the voltage drop shall be based on the calculated demand load of the feeder or branch circuit.

13 8-102 Voltage drop (cont d) (3) Notwithstanding Subrule (1), wiring for generaluse branch circuits rated at not more than 120 V or 20 A in dwelling units, with the conductor length measured from the supply side of the consumer s service to the furthest point of utilization in accordance with the values in Table 68, shall be acceptable.

14 Section 8 Appendix B Notes to Rule (3) This Rule is not intended to apply to branch circuits for the following: (a) household appliances (e.g., refrigerators, washing machines, central vacuum systems, and other receptacles as per Rule ); (b) kitchen counter receptacles Rule (b) and dining room receptacle c/w gas range receptacle Rule (e); (c) electrical heating and cooking appliances (Rule ); and (d) other specific receptacles installed in dwellings, such as those dedicated for medical devices. These branch circuits must still meet Subrule (1) requirements!

15 8-102 Voltage drop (cont d) (4) Notwithstanding Subrule (1), at industrial establishments where conditions of maintenance and supervision ensure use by qualified persons, the design shall ensure that the voltage at the point of utilization is within the rating or voltage tolerance of the connected device(s).

16 Section Use of demand factors (see Appendix B) New Subrule (6) (6) Where a feeder or service supplies motor or air-conditioning loads, a demand factor as determined by a qualified person shall be permitted to be applied to these loads, provided that a deviation has been allowed in accordance with Rule

17 Section Use of demand factors (see Appendix B) New Subrule (10) (10) For loads other than those calculated in accordance with Rules and 8-202, feeder and service load calculations shall be permitted to be based on demonstrated loads, provided that such calculations are performed by a qualified person, as determined by the regulatory authority having jurisdiction. ETAC has requested the BCSA develop a Bulletin describing the experience and credentials required to be recognized as qualified

18 Section 10 Rule Material for grounding conductors (see Appendix B) (1) The grounding conductor shall be permitted to be insulated or bare and shall be of copper, aluminum, or other acceptable material. (2) The material for grounding conductors shall be resistant to any corrosive condition existing at the installation or shall be protected against corrosion. BC Amendment proposed (later in this presentation)

19 Section Classification of hazardous locations (see Appendices B, J, and L) Hazardous locations shall be classified according to the nature of the hazard, as follows: (a) explosive gas atmospheres; or (b) explosive dust atmospheres. Introduction of Zone 20 locations Harmonization with International IEC standards Equipment with equivalent protection schemes accepted Similar to adoption of IEC standards for hazardous gas installations in 2002

20 Section Branch circuits for dwelling units (see Appendix B) (f) each branch circuit supplying 125 V receptacles rated 20 A or less shall be protected by a combination-type arc-fault circuit interrupter, except for branch circuits supplying (i) receptacles installed in accordance with (A) Rule (f); or (B) Rule (d)((i), (iii), (iv), and (v); and (ii) a single receptacle for a sump pump

21 Section Branch circuits for dwelling units (see Appendix B) (g) notwithstanding Item (f), the entire branch circuit need not be provided with arc-fault protection where (i) an outlet branch-circuit-type arc-fault circuit interrupter is installed at the first outlet on the branch circuit; and (ii) the wiring method for the portion of the branch circuit between the branch circuit overcurrent device and the first outlet consists of metal raceway, armoured cable, or non-metallic conduit or tubing.

22 Section Branch circuits for dwelling units (see Appendix B) Will not apply to circuits supplying: Bathroom and washroom receptacles (dedicated ccts only) Refrigerators Kitchen counter receptacles, kitchen island receptacles, peninsula counter receptacles Single receptacle for sump pump (with restrictions)

23 Section 26 Arc fault circuit protection for new branch circuit wiring in new construction and existing dwelling units as per Rule Rationale: Expands the use of arc fault circuit interrupters to other areas of a residence where portable electrical appliances and equipment are regularly used According to Canadian fire statistics, AFCI devices have reduced the number of fatal residential fires

24 Section 26 Arc fault circuit protection for new branch circuit wiring in new construction and existing residences as per Rule Impacts: Estimated cost increases (per dwelling unit): Type of arc fault protection 2-bedroom apartment (wood framed) High rise apartment (concrete) 3000 sq.ft. house Combination-type $ $850-$950 Blank/dead faced $400 $730 Receptacle $450 $250 $830

25 Section 50 - Deleted Solar photovoltaic systems moved to Section 64. Rationale: PV is a renewable energy source and should be grouped with similar renewable energy types Common installation requirements already found in Section 64

26 Section 64 Renewable energy systems Solar photovoltaic systems - Rules Conductor marking or colour coding (see Appendix B) (1) Notwithstanding Rule 4-038, dc photovoltaic output circuit conductors, and photovoltaic source circuit conductors installed between a module and the power conditioning unit of the dc system, shall be coloured or coded, or both, as follows: (a) for a 2-wire circuit (i) red for positive and black for negative;. (b) for a 3-wire circuit (bipolar circuit) (i) white, grey, or white with a coloured stripe for mid-wire (2) The requirements of Subrule (1) shall not be met by field marking or labelling.

27 Section 64 Renewable energy systems (3) Notwithstanding Subrule (2), conductor colour coding for multiconductor cables required in Subrule (1) shall be permitted to be made through suitable field labelling or marking in a permanent manner. (4) Conductor labelling and marking permitted in Subrule (3) shall (a) be made at every point where the separate conductors are rendered accessible and visible by removal of the outer covering of the cable; (b) be made by painting or other suitable means; and (c) not render the manufacturer s numbering of the conductors illegible.

28 Section 64 Renewable energy systems Photovoltaic dc arc-fault circuit protection (1) Photovoltaic systems with dc source circuits or output circuits, or both, and operating at a maximum system voltage of 80 V or greater, shall be protected by (a) a dc arc-fault circuit interrupter; or (b) other system equipment approved to provide equivalent protection. (2) The arc-fault protection system required in Subrule (1)(b) shall (a) detect and interrupt arcing faults. (b) not have the capability of being automatically restarted; (c) have annunciation, (d) disable or disconnect,...

29 Section 64 (cont d) Rationale: Provide increased safety by reducing the risk of fires and failures Impacts: Installation costs are expected to increase for new safety requirements: additional equipment, training requirements and correlation with other relevant standards.

30 Section 66 - Amusement parks, midways, carnivals, film and TV sets, TV remote broadcasting locations, and travelling shows Scope (1) This Section applies to the temporary installation of electrical equipment, utilizing any source of electrical power, for (a) amusement parks; (b) midways; (c) carnivals; (d) fairs; (e) film, television, and radio productions; (f) remote broadcasting and recording locations; (g) live performance and entertainment events; (h) touring shows and productions; (i) concerts; (j) sporting events; (k) trade shows; and (l) similar events.

31 Section 66 cont d Receptacles Receptacles having CSA configuration 5-15R or 5-20R installed in itinerant midways, carnivals, fairs, and festivals and intended to supply loads in outdoor or damp locations shall be protected by ground fault circuit interrupters of the Class A type.

32 Section 66 cont d Single-conductor cable connections (see App. I) (2) Plug-in connectors for single-conductor cables shall (a) no change (b) no change, and (c) have all connections that are not in use covered with a seal or cap that is acceptable. (5) In-line single-conductor cable connections forming part of a circuit of more than 150 volts-to-ground shall be mechanically protected by enclosing the connector(s) in a lockable, non-conductive box or similar enclosure. (6) The lockable enclosure referred to in Subrule (5) shall (a) be labelled on the outside, in a conspicuous, legible, and permanent manner, identifying the supply voltage of the circuit; and (b) be acceptable.

33 Section 66 cont d Single-conductor cable connections (see App. I) (7) No more than one tapping or parallel tee per conductor shall be used at any one point in a power distribution system. (8) Any distribution splitting or combining devices requiring more than two load connections per conductor shall use a single, approved multiple connection device at that point.

34 Section 66 cont d Summary: Scope has been expanded and clarified to include additional types of temporary installations Receptacles rated 125V, 15A and 20A shall be GFCI protected in outdoor and damp locations at carnivals, fairs and festivals Expanded requirements for single conductor cable connections

35 Section 66 Rationale: Fire safety Reduce shock risk to the public Impacts: Some costs are expected to increase with additional equipment required.

36 Section 76 Temporary wiring Rule Receptacles (See Appendix I) Receptacles having CSA configuration 5-15R or 5-20R installed to provide power for buildings or projects under construction or demolition shall be protected by ground fault circuit interrupters of the Class A type BCSA Bulletin allowed construction receptacles to be provided without GFCI protection when the Worksafe BC Assured grounding program was implemented and used at construction sites

37 Section 76 (cont d) Proposed: Adopt Code as written without a BC amendment requiring special permission to opt out of GFCI protection requirements as currently required in 2012 Code. Rationale: Special permission to utilize Work Safe BC s assured grounding program can be authorized by AHJ s under Rule Provides administrative streamlining for construction industry Provides administrative streamlining for AHJ s

38 Consultation on the adoption of the 2015 Canadian Electrical Code FEEDBACK, QUESTIONS & ANSWERS

39 How to give feedback/ask a question Unmute your phone line. State your name and your company name. Give your feedback: How do these changes affect you and your industry? or Ask your question. ** Please be considerate of other people on the call and limit your number of questions to two. More questions and feedback can be given at the end of the next presentation.

40 Consultation on the adoption of the 2015 Canadian Electrical Code PROPOSED BC AMENDMENTS

41 Proposed BC Amendments Section 0 Definitions Change electrical contractor Current text: Electrical contractor Any person, corporation, company, firm, organization, or partnership performing or engaging to perform, either for their or its own use or benefit, or for that of another, and with or without remuneration or gain, any work with respect to an electrical installation or any other work to which this Code applies. Proposed text: Electrical contractor means a licensed electrical contractor, as defined in the Electrical Safety Regulation;

42 Proposed BC Amendments Section 0 Definitions Change National Building Code of Canada Current text: National Building Code of Canada (No current definition) Proposed text: (provide a definition) National Building Code of Canada means the British Columbia Building Code and local building bylaws. Rationale: Keeps the current definitions of Electrical Contractor and National Building Code of Canada, consistent with other laws. Impacts: None.

43 Proposed BC Amendments Section 2 General Rules Rule 2-104(1) current text: (1) All electrical equipment marked with a short-circuit current rating or withstand rating shall have ratings sufficient for the voltage employed and for the fault current that is available at the terminals. Proposed changes for BC: Do not adopt Rule 2-104(1) (1) All electrical equipment marked with a short-circuit current rating or withstand rating shall have ratings sufficient for the voltage employed and for the fault current that is available at the terminals. Proposed text: None, delete Subrule entirely

44 Section 2: Rule 2-104(1) cont d Why? Rule cannot be enforced as written This was a newly introduced rule in the 2015 edition of the Canadian Electrical Code. Impact: None.

45 Section 10 Grounding and bonding Current 2015 Code Section 10 Rule , Effective Grounding Rule and Appendix B notes have been deleted Former Rule and Appendix B notes required the path to ground for circuits and equipment to be continuous, have ample ampacity and have impedance sufficiently low for operation of O/C devices Proposed changes for BC: Add (See Appendix B Note) to title of Rule , Object Add information and definitions from previous Rule and Appendix B notes as a new Appendix B note to Rule

46 Rule (cont d) Revised text as a Rule Appendix B note: Objective of bonding is to have an impedance sufficiently low in order to: (a) facilitate the operation of the overcurrent devices in the circuit on the occurrence of a fault of negligible impedance from an energized or phase conductor to exposed metal; and (b) limit the duration of the voltage above ground on this exposed metal. This objective is accomplished by means of completing the fault path of the bonding arrangement of the consumer s installation which would normally have to be such that a current of not less than five times the rating of the overcurrent device protecting the circuit will flow on the occurrence of a fault of negligible impedance via a bonding conductor back to the solidly grounded source.

47 Rule (cont d) Rationale: Retains information from Rule of the 2012 edition of the Canadian Electrical Code, which was removed from the 2015 edition. BCSA will publish an information bulletin providing rationale and clarifications on amended provisions. Impact: None. Information provided in previous Code editions

48 Rule , Material for grounding conductors Current 2015 Code text: Material for system grounding conductors (1) The grounding conductor shall be permitted to be insulated or bare and shall be of copper, aluminum, or other acceptable material. (2) The material for grounding conductors shall be resistant to any corrosive condition existing at the installation or shall be protected against corrosion.

49 Rule Material for grounding conductors (cont d) Proposed changes for BC: Rule , Material for grounding conductors Change Rule by; Change wording in Subrule (1), Add new Subrules (2) and (3), and Renumber existing Subrule (2) as the new Subrule (4)

50 Section 10 Proposed 2015 Code text: Material for grounding conductors (1) Except as permitted by Subrules (2) or (3), the grounding conductor shall be insulated or bare and shall be of copper. (2) A grounding conductor shall be permitted to be of aluminum for installation in dry locations only. (3) Where a deviation has been allowed in accordance with Rule 2-030, the grounding conductor shall be permitted to be of other acceptable material. (4) The material for grounding conductors shall be resistant to any corrosive condition existing at the installation or shall be protected against corrosion.

51 Rule Material for grounding conductors (cont d) Rationale: Clarifies the requirements where Aluminum grounding conductors may be used Requires special permission to use other conductor materials as a grounding conductor consistent with previous requirements Impact: No impact. Installers will be able to use aluminum as an acceptable material for grounding conductors in dry locations, and copper in either setting.

52 Consultation on the adoption of the 2015 Canadian Electrical Code FEEDBACK, QUESTIONS & ANSWERS

53 How to give feedback/ask a question Unmute your phone line. State your name and your company name. Give your feedback: Do you agree with these proposed BC amendments? or Ask your question. ** Please be considerate of other people on the call and limit your number of questions to two. If we cannot answer your question at this time, we will post our response via on the CEC consultation webpage.

54 Questions? Comments? Sec / Rule Issue 0 Proposed change for BC: Definitions of Electrical contractor and National Building Code of Canada 2-104(1) Proposed change for BC: Do not adopt (equipment ratings) Clarifies ampacities issues from 2012 edition & -106 Voltage drop calculations and use of demand factors & -802 Proposed change for BC: Allows for use of aluminum as ground conductor in dry locations (see Appendix) 18 Classification of hazardous locations with regard to combustible dust 26 Expanded use of arc fault circuit protection in residences 64 (Formerly section 50): Renewable energy systems, including photovoltaic systems 66 Temporary installation of electrical equipment Assured Grounding Program to be authorized under Appendices Proposed change for BC: Add Appendix B Note on Rule (1) for objectives of bonding Tables Expanded Table 6 (conductors in raceways) and Table 9 (cross sectional areas of raceways)

55 Thank you for attending! Webpage Questions? More comments? Meryl Howell-Fellows, Stakeholder Engagement Programs Coordinator: Results Posted after the consultation closes on May 15, 2015

ELECTRICAL BULLETIN

ELECTRICAL BULLETIN PO Box 697 Halifax, Nova Scotia B3J 2T8 ELECTRICAL BULLETIN 2015-01 From: David MacLeod, C.E.I., P.Eng. Pg. 1 of 7 Provincial Chief Electrical Inspector Date: March 10, 2015 Subject: Adoption of the 2015

More information

BULLETIN LICENSED ELECTRICAL CONTRACTORS. SaskPower Electrical Inspections. June 13, Item #1 Arc-Fault Receptacles, CEC Rule (f)

BULLETIN LICENSED ELECTRICAL CONTRACTORS. SaskPower Electrical Inspections. June 13, Item #1 Arc-Fault Receptacles, CEC Rule (f) SaskPower Electrical Inspections BULLETIN 01-2014 June 13, 2014 TO: LICENSED ELECTRICAL CONTRACTORS SUBJECT: GENERAL BULLETIN Item #1 Arc-Fault Receptacles, CEC Rule 26-722(f) For the purposes of this

More information

BULLETIN SUBJECT: GENERAL BULLETIN, 2015 SASK INTERPRETATIONS CORRECTIONS, AND ELECTRIC SERVICE REQUIREMENT CHANGES OR ADDITIONS

BULLETIN SUBJECT: GENERAL BULLETIN, 2015 SASK INTERPRETATIONS CORRECTIONS, AND ELECTRIC SERVICE REQUIREMENT CHANGES OR ADDITIONS SaskPower Electrical Inspections BULLETIN 01-2017 February 15, 2017 TO: LICENSED ELECTRICAL CONTRACTORS ELECTRICAL CONSULTANTS AND ENGINEERS SUBJECT: GENERAL BULLETIN, 2015 SASK INTERPRETATIONS CORRECTIONS,

More information

Canadian Electrical Code, Part I Full Impact Assessment

Canadian Electrical Code, Part I Full Impact Assessment Copyright CSA Group 2015 Canadian Electrical Code, Part I Full Impact Assessment Subject 3644 Polarity identification for photovoltaic (PV) dc system conductors & Subject 3694 Photovoltaic (PV) dc arc-fault

More information

ELECTRICAL BULLETIN

ELECTRICAL BULLETIN PO Box 697 Halifax, Nova Scotia B3J 2T8 Labour and Advanced Education ELECTRICAL BULLETIN 2012-01 From: David MacLeod,C.E.I.,P.Eng. Pg 1 of 8 Provincial Chief Electrical Inspector Date : March 1, 2012

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 11/10/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 11/10/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 11/10/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. If a microwave oven, or refrigerator or freezer has a

More information

Click here to get back to 2011 NEC Code Updates Part 1

Click here to get back to 2011 NEC Code Updates Part 1 www.garyklinka.com Page 1 of 13 2011 NEC Code Updates Code Language Part 1 Click here to get back to 2011 NEC Code Updates Part 1 100 Definitions Ampacity. The maximum current, in amperes, that a conductor

More information

INFORMATION BULLETIN

INFORMATION BULLETIN APPROVAL OF MANUFACTURED HOMES & FACTORY-BUILT STRUCTURES (RELOCATABLE AND NON-RELOCATABLE) The following bulletin provides guidance on the application Electrical Safety Regulation, Section 21. This information

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. We were turned down for an underground installation of

More information

The following chapters or articles of the New Jersey electrical subcode are amended as follows:

The following chapters or articles of the New Jersey electrical subcode are amended as follows: The following chapters or articles of the New Jersey electrical subcode are amended as follows: 90.4 Enforcement. This Code is intended to be suitable for mandatory application by governmental bodies that

More information

Manitoba Electrical Code

Manitoba Electrical Code THE MANITOBA HYDRO ACT (C.C.S.M. c. H190) Manitoba Electrical Code Regulation 76/2018 Registered June 15, 2018 Adoption of Canadian Electrical Code, Part I, 24th edition 1 Subject to section 3 and the

More information

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999 CANADIAN ELECTRICAL CODE 1 The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999 Repealed by Chapter E-6.3 Reg 8 (effective June 24, 2003). Formerly Chapter E-6.3 Reg 6 (effective March

More information

INFORMATION BULLETIN

INFORMATION BULLETIN TEMPORARY AND PERMANENT SERVICES FOR CONSTRUCTION POWER Date of Issue: February 29, 2016 NO: IB-EL-2016-03 The following bulletin provides guidance on the application of rules pertaining to the 2015 BC

More information

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp, TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2011 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.

More information

Sections through of Chapter 5 of the Victoria City Code are amended to read as follows: ARTICLE IX. NATIONAL ELECTRICAL CODE

Sections through of Chapter 5 of the Victoria City Code are amended to read as follows: ARTICLE IX. NATIONAL ELECTRICAL CODE Sections 5-100 through 5-105 of Chapter 5 of the Victoria City Code are amended to read as follows: ARTICLE IX. NATIONAL ELECTRICAL CODE Sec. 5-100. Adoption of published code. There is hereby adopted

More information

Revised October 2017, the information contained in this bulletin supercedes the requirements of all previous bulletins.

Revised October 2017, the information contained in this bulletin supercedes the requirements of all previous bulletins. EB 0901 Revised October 2017, the information contained in this bulletin supercedes the requirements of all previous bulletins. 1. An Electrical Permit must be purchased BEFORE electrical work is carried

More information

2015 Code Rollout Meeting Q & A

2015 Code Rollout Meeting Q & A 1 SECTION QUESTION SaskPower Inspections Dept. ANSWER 2 3 4 5 6 7 8 9 10 11 12 15-02-024 15-02-200 15-02-200 15-02-200 15-02-314 Are existing single or double 'weather proof when not in use' covers allowed

More information

Homeowner electrical wiring guide. Including the 2015 Canadian Electrical Code amendments

Homeowner electrical wiring guide. Including the 2015 Canadian Electrical Code amendments Homeowner electrical wiring guide Including the 2015 Canadian Electrical Code amendments Table of Contents Homeowner electrical wiring guide... 1 Required inspections... 2 Rough inspections (prior to any

More information

Top Changes 2014 NEC

Top Changes 2014 NEC Top Changes 2014 NEC MICHAEL JOHNSTON EXECUTIVE DIRECTOR STANDARDS AND SAFETY NECA General Information This presentation previews significant changes for the 2014 NEC. Two-part series on 2014 NEC changes

More information

Certification Requirements for Manufactured Homes and RV s

Certification Requirements for Manufactured Homes and RV s Certification Requirements for Manufactured Homes and RV s Table of Contents About the BC Safety Authority... 2 Who is the BC Safety Authority?... 2 What We Do... 2 Manufactured Homes and Buildings...

More information

Proposals and Process 2017 National Electrical Code

Proposals and Process 2017 National Electrical Code Proposals and Process 2017 National Electrical Code for Solar America Board for Codes and Standards Stakeholder Meeting; October 23, 2014 Ward Bower Ward Bower Innovations LLC Introduction The New NFPA

More information

Temporary Wiring. Low-Voltage Electrical Safety Orders

Temporary Wiring. Low-Voltage Electrical Safety Orders Temporary Wiring Low-Voltage Electrical Safety Orders 2405.1. Scope. Except as specifically modified in this Article, all other requirements of this Order for permanent wiring shall also apply to temporary

More information

Bulletin Grounding and bonding of solar photovoltaic systems Rules , , , and

Bulletin Grounding and bonding of solar photovoltaic systems Rules , , , and Bulletin 64-2-0 Grounding and bonding of solar photovoltaic systems Rules 64-064, 64-066, 64-068, 64-070 and 64-222 Scope (1) Introduction (2) Grounding of solar photovoltaic system output, ac grounding

More information

Amendment A National Electric Code

Amendment A National Electric Code Amendment A-5 2014 National Electric Code Part 5 BUILDING REGULATIONS AND CODES National Electric Code, 2014 Edition (NEC, 2014) Part 5, Chapter 5 National Electric Code Article 100 I. General ENGINEERING

More information

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

CITY OF GRANDE PRAIRIE

CITY OF GRANDE PRAIRIE Inspection Services CITY OF GRANDE PRAIRIE HOMEOWNER S PERMIITS AND WIRING GUIDE FOR ELECTRICAL INSTALLATIONS 2016 INDEX Page Applying for an Electrical Permit 3 Permit Application Requirements 3 Permit

More information

Reference Information:

Reference Information: Solar PV Simplified Standard Permit Application Requirements For: Central/String Inverter(s) & Micro-Inverter(s) Systems for One and Two Family Dwellings SCOPE: Use this application only for utility-interactive

More information

Canadian Electrical Code Full Impact Assessment

Canadian Electrical Code Full Impact Assessment Canadian Electrical Code Full Impact Assessment Subject 3931 Update Section 26: Revisions to exceptions for AFCI protection CONTENTS 1 INTRODUCTION TO THE FULL IMPACT ASSESSMENT... 3 2 PURPOSE OF THE FULL

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan) TOOLKIT DOCUMENT #7 Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan) This document has two sections. Neither section is all-inclusive

More information

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE:

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE: Solar Panels Interactive PV system checklist: 1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ 107.2 CBC] 2. The electrical plans show a different number of panels than

More information

CONSISTENCY MEETING DEPARTMENTAL GOALS: % 1 DAY TURN AROUND % CONTRACTOR PASS RATE QUALITY INSPECTIONS! EXCELLENT CUSTOMER SERVICE!

CONSISTENCY MEETING DEPARTMENTAL GOALS: % 1 DAY TURN AROUND % CONTRACTOR PASS RATE QUALITY INSPECTIONS! EXCELLENT CUSTOMER SERVICE! CONSISTENCY MEETING Date: 3/12/2014 DEPARTMENTAL GOALS: 85-90 % 1 DAY TURN AROUND 80-85 % CONTRACTOR PASS RATE QUALITY INSPECTIONS! EXCELLENT CUSTOMER SERVICE! SAFETY ISSUES: REMEMBER COUNTY CELL PHONE

More information

Replace 210.8(a)(7) with: Sinks. Where receptacles are installed within 6 feet of the outside edge of a sink. Page 1 of 5

Replace 210.8(a)(7) with: Sinks. Where receptacles are installed within 6 feet of the outside edge of a sink. Page 1 of 5 CHAPTER 23.30 LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2002 EDITION SECTIONS: 23.30.010 Local Amendments to the National Electrical Code 2002 Edition 23.30.020 Certificate of Fitness - Right to

More information

Basic Requirements for Residential Electrical Installations

Basic Requirements for Residential Electrical Installations Basic Requirements for Residential Electrical Installations Wayne County Building Department 428 West Liberty Street Wooster, Ohio 44691 Phone: 330-287-5525 Fax: 330-287-5649 This brochure is intended

More information

Article 10 - ADMINISTRATIVE SECTION

Article 10 - ADMINISTRATIVE SECTION Article 10 - ADMINISTRATIVE SECTION 10.1 TITLE These Administrative Regulations along with the requirements included in the 2005 Edition of the National Electrical Code (NFiPA-70-2005) as approved by the

More information

About Matt Piantedosi

About Matt Piantedosi 2017 NFPA Conference & Expo Solar PV System Inspections Best Practices and Commonly Found Violations Presented by: Matt Piantedosi Manager of Solar Field Operations The Cadmus Group About Matt Piantedosi

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Is it illegal to install a wet-niche luminaire face-up

More information

Ground Fault Circuit Interrupters (GFCI) & Assured Grounding Program

Ground Fault Circuit Interrupters (GFCI) & Assured Grounding Program Ground Fault Circuit Interrupters (GFCI) & Assured Grounding Program Applicable OSHA Standards: 29 CFR 1926.404 1. PURPOSE & SCOPE a.) To establish methods, guidelines and responsibilities to protect Vision

More information

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013 IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013 2011 National Electrical Code (NEC) Update Statement The National Electrical Code, 2011 Edition, with Appendices,

More information

HOMEOWNER PERMITS AND ELECTRICAL WIRING GUIDE

HOMEOWNER PERMITS AND ELECTRICAL WIRING GUIDE HOMEOWNER PERMITS AND ELECTRICAL WIRING GUIDE Revised 20 1 APPLICATION FOR HOMEOWNER PERMITS This pamphlet is only a guide. It describes methods of installation that have been tried and tested and which

More information

Code Change Alert: Permitting of Solar Photovoltaic Systems in Washington State

Code Change Alert: Permitting of Solar Photovoltaic Systems in Washington State Code Change Alert: Permitting of Solar Photovoltaic Systems in Washington State Emergency Rule Regarding Rooftop Solar Photovoltaic Installations On June 13, 2014 the Washington State Building Code Council

More information

DEPARTMENT OF PLANNING SERVICES BUILDING INSPECTION DIVISION 1555 N 17 TH AVENUE, GREELEY, CO (970)

DEPARTMENT OF PLANNING SERVICES BUILDING INSPECTION DIVISION 1555 N 17 TH AVENUE, GREELEY, CO (970) DEPARTMENT OF PLANNING SERVICES BUILDING INSPECTION DIVISION 1555 N 17 TH AVENUE, GREELEY, CO 80631 (970) 400-6100 BASIC REQUIREMENTS FOR WIRING A SINGLE FAMILY DWELLING Colorado State law permits individuals

More information

CHAPTER LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2011 EDITION

CHAPTER LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2011 EDITION CHAPTER 23.30 LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2011 EDITION Sections 23.30.010 Local amendments to the National Electrical Code 2011 Edition.... 1 23.30.020 Certificate of fitness - right

More information

Grounding & Bounding. 1. Bonded Connected to establish electrical continuity and conductivity.

Grounding & Bounding. 1. Bonded Connected to establish electrical continuity and conductivity. & Bounding Article 100 Definitions 1. Bonded Connected to establish electrical continuity and conductivity. 2. Raceway fittings bonds sections of raceway Bonding jumper bonds receptacles to boxes Threaded

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin February 2019 Page 1 of 5 2018 CANADIAN ELECTRICAL CODE SUBJECT: Section 6 Services and service equipment Rule 6-102 Number of supply services permitted Row housing

More information

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19 TABLE OF CONTENTS About This Textbook... xvii How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...

More information

Small Wind Turbine Electrical System Considerations

Small Wind Turbine Electrical System Considerations Small Wind Turbine Electrical System Considerations Presented by: Tom Buchal Senior Staff Engineer Intertek Renewables International Small Wind Association of Testers Conference Ithaca, NY April 25, 2012

More information

Questions & Answers. Amendments to Ontario Electrical Safety Code 23 rd Edition/2002

Questions & Answers. Amendments to Ontario Electrical Safety Code 23 rd Edition/2002 Questions & Answers Amendments to Ontario Electrical Safety Code 23 rd Edition/2002 When do the new rules become effective? Ontario amendments to the Ontario Electrical Safety Code 23 rd Edition/2002 comes

More information

SERVICES - SERVICE EQUIPMENT- PANELBOARDS

SERVICES - SERVICE EQUIPMENT- PANELBOARDS NO: D-E3 101110 1 THIS DIRECTIVE SUPERSEDES DIRECTIVES D-E3 070302 5 & D-E3 070302 6 SERVICES - SERVICE EQUIPMENT- PANELBOARDS This Directive is being issued by a provincial safety manager pursuant to

More information

Hazards. Hazards. Hazards. Effects on the Body. GA Tech Electrical Safety Presentation

Hazards. Hazards. Hazards. Effects on the Body. GA Tech Electrical Safety Presentation Hazards The direct result can be electrocution. SHOCK. Electric shock occurs when the human body becomes part of the path through which current flows. The indirect result can be injury resulting from a

More information

About This Textbook... xvii About the National Electrical Code...xxi About the Author... xxv About the Illustrator... xxvi About the Team...

About This Textbook... xvii About the National Electrical Code...xxi About the Author... xxv About the Illustrator... xxvi About the Team... About This Textbook... xvii About the National Electrical Code...xxi About the Author... xxv About the Illustrator... xxvi About the Team...xxvii Article 90 Introduction to the National Electrical Code...

More information

SOUTHERN NEVADA AMENDMENTS TO THE 2018 NATIONAL ELECTRICAL CODE

SOUTHERN NEVADA AMENDMENTS TO THE 2018 NATIONAL ELECTRICAL CODE SOUTHERN NEVADA AMENDMENTS TO THE 2018 NATIONAL ELECTRICAL CODE PREFACE This document was developed by the Southern Nevada Building Officials National Electrical Code and presents recommended amendments

More information

SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE

SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE PREFACE This document was developed by the Southern Nevada Building Officials National Electrical Code and presents recommended amendments

More information

2. Article (A) Delete the measurement of 6 feet 7 inches and insert: 66 inches (5 feet 6 inches).

2. Article (A) Delete the measurement of 6 feet 7 inches and insert: 66 inches (5 feet 6 inches). H. The National Electric Code 2011 is hereby revised: 1. Article 230.70 (A) (1) Delete in its entirety and insert: 230.70 (A) (1) Readily Accessible Location. The service disconnect means shall be installed

More information

PLEASE FOLLOW INSTRUCTIONS ON PAGE FIVE

PLEASE FOLLOW INSTRUCTIONS ON PAGE FIVE WASHINGTON STATE BUILDING CODE COUNCIL APPLICATION FOR REVIEW OF A PROPOSED STATEWIDE AMENDMENT TO THE WASHINGTON STATE BUILDING CODE 2012 Code Adoption Cycle Log # (office use only) PLEASE FOLLOW INSTRUCTIONS

More information

SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE AS AMENDMEND BY THE CITY OF NORTH LAS VEGAS

SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE AS AMENDMEND BY THE CITY OF NORTH LAS VEGAS SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE AS AMENDMEND BY THE CITY OF NORTH LAS VEGAS Page 5 of 19 Dated: June 15, 2018 PREFACE This document was developed by the Southern Nevada

More information

Appendix C - International NEC Electric Code Amendments

Appendix C - International NEC Electric Code Amendments - International NEC Electric Code Amendments The International NEC Electric Code shall be amended as follows: (Revised Ord 2016-52) Section 220.14(A) Specific Appliances or Loads. At the end of this Sub-Section,

More information

AS/NZS 3000: 2018 Changes to Wiring Rules Standard

AS/NZS 3000: 2018 Changes to Wiring Rules Standard BUILDING SERVICES Ref: BCA 19-01 Current at January 2019 AS/NZS 3000: 2018 Changes to Wiring Rules Standard The new edition of AS/NZS 3000 Wiring Rules Standard (Electrical Installations) was published

More information

ELECTRICAL CODE TRADE REFERENCE

ELECTRICAL CODE TRADE REFERENCE ELECTRICAL CODE TRADE REFERENCE FIFTH EDITION By Marvin Rosenberg UNIT 2: CODE COMPONENTS General Rule Sections 0 Definitions accurate interpretation 2 General Rules administrative and technical requirements

More information

SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE AS AMENDMEND BY THE CITY OF NORTH LAS VEGAS

SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE AS AMENDMEND BY THE CITY OF NORTH LAS VEGAS SOUTHERN NEVADA AMENDMENTS TO THE 2017 NATIONAL ELECTRICAL CODE AS AMENDMEND BY THE CITY OF NORTH LAS VEGAS I 1 CITY OF NORTH LAS VEGAS PREFACE This document was developed by the Southern Nevada Building

More information

New Jersey Chapters July NEC updates. The Association of Electrical and Medical Imaging Equipment Manufacturers

New Jersey Chapters July NEC updates. The Association of Electrical and Medical Imaging Equipment Manufacturers New Jersey Chapters July 2016 2017 NEC updates The Association of Electrical and 2016 NFPA CAMs 43 NITMAM (Notice Intent To Make a Motion) Certified Amending Motions (CAMs) submitted for NFPA 70 12 CAMs

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin February 2019 Page 1 of 8 2018 CANADIAN ELECTRICAL CODE SUBJECT: Section 10 Grounding and bonding Rule 10-102 Grounding electrodes Replacing metal water service lines

More information

EFFECTIVE DATE: July 1, 2008, unless a later date is cited at the end of a section. [ NMAC - Rp,

EFFECTIVE DATE: July 1, 2008, unless a later date is cited at the end of a section. [ NMAC - Rp, TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2008 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.

More information

Emergency, Legally Required, and Optional Standby Power Systems

Emergency, Legally Required, and Optional Standby Power Systems Mike Holt s Illustrated Guide to Emergency, Legally Required, and Optional Standby Power Systems Rule 220.87, Articles 445, 700, 701, and 702 Based on the 2011 NEC Extracted from Mike Holt s Illustrated

More information

SERVICES AND. Topic: requirements. installations. service pole met; and. braced. Page 1 of 9

SERVICES AND. Topic: requirements. installations. service pole met; and. braced. Page 1 of 9 INFORMATION BULLETIN SERVICES AND SERVICE EQUIPMENT Date of Issue: October 1, 2012 NO: IB-EL 2012-03 Topic: Services and Servicee Equipment This Information Bulletin supplements the Directive on: Services

More information

Building Permit Application

Building Permit Application Building Permit Application Administrative Use Only PARENT PERMIT NUMBER (Required if part of another project) PERMITTEE: PERMITTEE ADDRESS: E-MAIL ADDRESS: ARCHITECT/ENGINEER: ARCHITECT/ENGINEER ADDRESS:

More information

2017 NEC Changes for Renewable Energy Systems Session one by Christopher LaForge

2017 NEC Changes for Renewable Energy Systems Session one by Christopher LaForge 2017 NEC Changes for Renewable Energy Systems Session one 2017 by Christopher LaForge Christopher LaForge IREC Certified Master Trainer NABCEP Certified Photovoltaic Installation Professional 30 years

More information

BUILDING/FIRE/ZONING PERMIT GUIDE

BUILDING/FIRE/ZONING PERMIT GUIDE BUILDING/FIRE/ZONING PERMIT GUIDE Summary Guidelines The following is an instructional guide that will serve to assist you in securing the various permits issued by the Bureau of Code Administration. In

More information

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes.

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes. CHAPTER 35 SERVICES SECTION E3501 GENERAL SERVICES E3501.1 Scope. This chapter covers service conductors and equipment for the control and protection of services and their installation requirements. E3501.2

More information

CITY & COUNTY OF DENVER COMMUNITY PLANNING & DEVELOPMENT BUILDING PERMIT POLICY

CITY & COUNTY OF DENVER COMMUNITY PLANNING & DEVELOPMENT BUILDING PERMIT POLICY Page 1 of 5 REFERENCE Denver Building and Fire Code (DBC) Section 131, International Residential Code (IRC) Section M2301, the National Electrical Code (NEC) Articles 690 & 705 PROCEDURE The procedure

More information

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL). 16450 GROUNDING ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 05 26 An optional keynote to the

More information

SECTION GROUNDING

SECTION GROUNDING SECTION 16450 GROUNDING PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies general grounding and bonding requirements of electrical and telecommunication installations for personnel safety, equipment

More information

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES Guidelines effective March 5, 2007 NES is committed to providing safe, reliable electric service at a reasonable price for all of our customers. These guidelines offer direction for activities relating

More information

1 of 1 DOCUMENT. NEW JERSEY REGISTER Copyright 2008 by the New Jersey Office of Administrative Law. 40 N.J.R. 5900(a)

1 of 1 DOCUMENT. NEW JERSEY REGISTER Copyright 2008 by the New Jersey Office of Administrative Law. 40 N.J.R. 5900(a) 1 of 1 DOCUMENT NEW JERSEY REGISTER Copyright 2008 by the New Jersey Office of Administrative Law VOLUME 40, ISSUE 20 ISSUE DATE: OCTOBER 20, 2008 RULE PROPOSALS COMMUNITY AFFAIRS DIVISION OF CODES AND

More information

NY State Unified Solar Permit

NY State Unified Solar Permit PERMIT APPLICATION NY State Unified Solar Permit Unified solar permitting is available statewide for eligible solar photovoltaic (PV) installations. Municipal authorities that adopt the unified permit

More information

Photovoltaic System Inspector Job Task Analysis Guide April 2017

Photovoltaic System Inspector Job Task Analysis Guide April 2017 Photovoltaic System Inspector Job Task Analysis Guide April 2017 V. 04.17 www.nabcep.org Raising Standards. Promoting Confidence. NABCEP mission is to establish and operate high quality Credentialing programs

More information

City of Santa Monica Building and Safety Division

City of Santa Monica Building and Safety Division This is to be used as a general checklist; it is not inclusive of all code requirements and inspection criteria. General requirements Verify that address on permit matched Address, Description and Approvals:

More information

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin? What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin? How to compare apples-to-apples bids. By R. Dee Jones, P.E., AVO Training Institute Electrical Engineering Division Manager/Principal

More information

WITH THE TITLE 24. replacement. story. stories, etc. R disconnects. to, PV. unit and any. supporting frame. conditions. greater than the main

WITH THE TITLE 24. replacement. story. stories, etc. R disconnects. to, PV. unit and any. supporting frame. conditions. greater than the main CITY OF CYPRESS Building Division 5275 Orange Avenue, Cypress, California 906300 714-229-6730 buildingpermits@ @ci.cypress.ca.us RESIDENTIAL PHOTOVOLTAIC SYSEMS ALL WORK SHALL REQUIRE COMPLIANCE WITH THE

More information

NY State Unified Solar Permit

NY State Unified Solar Permit PERMIT APPLICATION NY State Unified Solar Permit Unified solar permitting is available statewide for eligible solar photovoltaic (PV) installations. Municipal authorities that adopt the unified permit

More information

Summary of the Changes 2017 National Electrical Code

Summary of the Changes 2017 National Electrical Code what impact they will have on your work. Article 90----Introduction to the National Electrical Code 90.2 Scope of the NEC. Changes to this section include the removal of conductors, equipment and raceways,

More information

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions C&G 2382 BS7671:2008 17 th Edition IEE Wiring Regulations 25 Questions 1. BS7671 states that installation design must take into account a. current copper prices b. the effects of climate change c. a comparison

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin March 2014 CEC-10 [rev-8] Page 1 of 8 CANADIAN ELECTRICAL CODE SUBJECT: Section 10 Grounding and Bonding Rule 10-204 Grounding Connections for Alternating-Current

More information

* All equipment grounding conductors shall be tested for continuity and shall be electrically continuous.

* All equipment grounding conductors shall be tested for continuity and shall be electrically continuous. 1 IMHOFF CUSTOM SERVICES INC> ASSURED EQUIPMENT GROUNDING CONDUCTOR PROGRAM Imhoff Custom Services Inc. assured equipment grounding conductor program is in place to assure workers are protected on construction

More information

Article Requirements for Electrical Installations (A) and (B) - Available Fault Current (New)

Article Requirements for Electrical Installations (A) and (B) - Available Fault Current (New) Article 110 - Requirements for Electrical Installations 110.24(A) and (B) - Available Fault Current (New) Code Language. (A) Field Marking. Service equipment in other than dwelling units shall be legibly

More information

Draft Regulations. Draft Regulation. Regulation to amend the Construction Code and the Regulation respecting the application of the Building Act

Draft Regulations. Draft Regulation. Regulation to amend the Construction Code and the Regulation respecting the application of the Building Act Part 2 GAZETTE OFFICIELLE DU QUÉBEC, September 27, 2017, Vol. 149, No. 39 2979 Draft Regulations Draft Regulation Building Act (chapter B-1.1) Construction Code Regulation Amendment Notice is hereby given,

More information

NY State Unified Solar Permit

NY State Unified Solar Permit PERMIT APPLICATION NY State Unified Solar Permit Unified solar permitting is available statewide for eligible solar photovoltaic (PV) installations. Municipal authorities that adopt the unified permit

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 280.21-300.50 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1000 volts II. Instillation III. Connecting Surge

More information

2011 National Electrical Code Update Training. Henrico County Department of Building Construction and Inspections

2011 National Electrical Code Update Training. Henrico County Department of Building Construction and Inspections 2011 National Electrical Code Update Training Henrico County Department of Building Construction and Inspections Questions Questions are Welcome!!! You are probably not the only person with the same question.

More information

2011 National Electrical Code Update Training

2011 National Electrical Code Update Training 2011 National Electrical Code Update Training Henrico County Department of Building Construction and Inspections 1 Questions Questions are Welcome!!! You are probably not the only person with the same

More information

SPECIFICATION. Compliance with this guideline and proper maintenance will ensure for essentially safe operation.

SPECIFICATION. Compliance with this guideline and proper maintenance will ensure for essentially safe operation. SPECIAL LUMINAIRES IN ENTERTAINMENT INDUSTRY 1. Objective The objective of this document is to establish safety guidelines for the maintenance and use of luminaires used in the motion picture, television,

More information

FDA Inc. Course# NEC 2017 Code Changes In Wiring & Protection

FDA Inc. Course# NEC 2017 Code Changes In Wiring & Protection FDA Inc. Course# NEC 2017 Code Changes In Wiring & Protection WWW.DISCOUNTPDH.COM Wiring & Protection Articles 210 250 210 Branch Circuits 215 Feeders 220 Branch-Circuit, Feeder, and Service Calculations

More information

Amendment: Accept Comment 7-14

Amendment: Accept Comment 7-14 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M (AMENDMENT) TO: FROM: NFPA Technical Correlating Committee

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the

More information

GILA RIVER FIRE DEPARTMENT REQUIREMENTS

GILA RIVER FIRE DEPARTMENT REQUIREMENTS GILA RIVER FIRE DEPARTMENT REQUIREMENTS Case Number: Date: 09/07/2016 Reviewer: G. Lindenmier #0305 Project Name: Portable Generators Special Events & Use Location: WHPDA Property Applicant: Applicant

More information

Address of Installation Building Permit #

Address of Installation Building Permit # TOWN OF NISKAYUNA NY State Unified Solar Permit Application One Niskayuna Circle, Niskayuna NY 12309 Phone: 518-386-4522 Fax: 518-386-4592 Email: buiding@niskayuna.org The Town of Niskayuna has adopted

More information

METERING INSTALLATION

METERING INSTALLATION 4.01 METERING SPECIFICATIONS METERING INSTALLATION Metering specifications will be issued to the customer by OPPD. Metering specifications are required before any work is started on all new wiring or additions

More information

DEVICES AND LUMINAIRES

DEVICES AND LUMINAIRES CHAPTER 40 DEVICES AND LUMINAIRES SECTION E4001 SWITCHES E4001.1 Rating and application of snap switches. General-use snap switches shall be used within their ratings and shall control only the following

More information

NY State Unified Solar Permit

NY State Unified Solar Permit PERMIT APPLICATION- City of Elmira NY State Unified Solar Permit Unified solar permitting is available statewide for eligible solar photovoltaic (PV) installations. Municipal authorities that adopt the

More information

NY State Unified Solar Permit

NY State Unified Solar Permit VILLAGE OF UPPER BROOKVILLE PERMIT APPLICATION NY State Unified Solar Permit Unified solar permitting is available statewide for eligible solar photovoltaic (PV) installations. Municipal authorities that

More information