STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information
|
|
- Colin West
- 6 years ago
- Views:
Transcription
1 Table of ontents Product Page No. Product Page No. Panel Information Profile...PST-2 Panel Overview...PST-2 Flashing Profiles Eave...PST- Extended Eave...PST- leat...pst- Stile Starter...PST- Box Gutter...PST- Box Gutter End...PST- Universal Gutter/Downspout Strap...PST- 4" x /2" Downspout...PST- 4" x /2" 95 Elbow...PST- Downspout Bracket...PST- Stile Valley...PST- Valley over...pst- Formed Rake...PST- Rake...PST- Rake Starter...PST- Pitch Break...PST-4 ounter Flashing...PST-4 Reglet Flashing...PST-4 Ridge/Hip over...pst-4 Formed Ridge...PST-4 Vent Drip...PST-4 Stile -losure...pst-4 Junction Sheet...PST-4 Stile Ridge Drip...PST-4 Design/Installation onsiderations Fastener Installation Technique...PST-8 ondition of Substructure...PST-8 Ventilation...PST-9 Panel Applications...PST-9 Detail onditions Eave Detail...PST-0 Extended Eave Detail...PST-0 Gutter Detail...PST- Valley Detail...PST- Slope hange Detail...PST-2 Endlap Detail...PST-2 Rake Detail...PST- Formed Rake Detail...PST- Rake Parapet Siding Detail...PST-4 Endwall with ounter Detail...PST-4 Endwall with Reglet Detail...PST-5 Junction Sheet Detail...PST-5 Ridge/Hip Detail...PST-6 Formed Ridge/Hip Detail...PST-6 Formed Vented Ridge Detail...PST-7 Roof Vent Detail...PST-7 Notes Notes...PST-8 Accessory Profiles Stile Inside/Outside losure...pst-5 Stile Formed Ridge losure...pst-5 Universal losure...pst-5 Tube Sealant...PST-5 Tape Sealant...PST-5 Rubber Roof Jack...PST-5 Touch-Up Paint...PST-5 Stile Roof Vent...PST-5 Vent Material...PST-5 Testing Information UL 580 Wind Uplift Information...PST-6 Section Properties and General Information...PST-7 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-
2 Panel Overview PANEL PROFILE 2" /2" Step /6" Available in lengths up to 20'-0" 2" 9.4" overage 42." Overall width 2" SLOPE SUBSTRATE OVERAGE LENGTH AVAILABILITY APPLIATION PERFORMANE TEST FASTENING SYSTEM FASTENERS MATERIALS FINISH The minimum recommended slope for any Stile roofing panel is :2. The recommended substrate is 5 /8" plywood with a 0 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure. If your application is over a solid substrate other than 5 /8" plywood, please contact the your Metal Sales branch location (see pages PGI-2-). Each panel has a coverage of 9.4" ( meter). factory cut length is '-0", and the maximum panel length is 20'-0". Lengths between '-0" and 20'-0" will be cut at '-0" increments. Stile panels are available in 26 Gauge Galvanized (G-90) coating. Architectural panel. UL 580, UL 790, UL 26, UL 228, Miami-Dade ounty, FB Direct Fasten (exposed). The fastener selection guide should be consulted for choosing proper fasteners for specific applications. Quantity and type of fastener must meet necessary loading and code requirements (see PGI-2-4). Steel Grade 40, per ASTM A-65 ** PVDF Fluorocarbon ** Meets both Kynar 500 and Hylar 5000 specifications. PST-2 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
3 Flashing Profiles EAVE EXTENDED EAVE LEAT /8" X* 2 /2" 5 /8" Hem Length 0'-2" - *Specify Slope Angle 6" /2" X* " 5 /8" Length 0'-2" - *Specify Slope Angle 2 /2" 5 /2" Length 0'-2" STILE STARTER BOX GUTTER BOX GUTTER END /8" /2" Hem " /2" 2 /8" X* 4" " " 4" " Length 0'-2" UNIVERSAL GUTTER/ DOWNSPOUT STRAP Hem Length 0'-2", 20'-" - *Specify Slope Angle DOWNSPOUT 4" x /2" 95 0 ELBOW 4" x /2" 4" /2" 4" /2" 6" /2" Length 0'-2", 20'-" (Also available 6" x 4") (Also available 6" x 4") DOWNSPOUT BRAKET VALLEY VALLEY OVER 4" X* /2" 2" Hem X* 5 /8" (Also available 6") Length 0'-2", 20'-" - *Specify Slope Angle Length 0'-2" - *Specify Slope Angle FORMED RAKE " 7 /8" RAKE 4" RAKE STARTER /2" 2 7 /8" /4" 2 /6" 2 /6" /4" Length '-6" Hem Length 0'-2", 20'-" 5 /8" 4 /2" Length 0'-2" Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-
4 Flashing Profiles (cont.) PITH BREAK OUNTER FLASHING REGLET FLASHING /2" X* 4" 5 /8" " /4" 2" " 6" /4" Hem Length 0'-2" - *Specify Slope Angle Length 0'-2" Length 0'-2" RIDGE/HIP OVER FORMED RIDGE VENT DRIP /2" /4" 5 /8" Hem X* /4" 7 /8" /2" 4" /4" /4" 6 5 /8" /4" /4" Length 0'-2", 20'-" - *Specify Slope Angle Length '-6" Length 0'-2" STILE -LOSURE JUNTION SHEET STILE RIDGE DRIP /4" /2" 2" 7 /8" X* 4 /2" 47 / 2 9 /6" Length 0'-2", 20'-" Length '-" *Specify Slope Angle - Indicates color side of flashing. PST-4 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
5 Accessory Profiles STILE INSIDE/OUTSIDE LOSURE STILE FORMED RIDGE LOSURE UNIVERSAL LOSURE Polyethylene Foam TUBE SEALANT Polyethylene Foam TAPE SEALANT " x / 2" x 50' Polyethylene Foam " x / 2" x 0' Polyethylene Foam RUBBER ROOF JAK 0. oz. artridge Urethane TOUH-UP PAINT 7 /8" X /6" X 25' Double Bead Butyl - Gray STILE ROOF VENT 4 /2" MINI ( /4" to /8" O.D. Pipe) #2 ( /4" to " O.D. Pipe) #4 (" to 6" O.D. Pipe) #6 (6" to 9" O.D. Pipe) #8 (7" to " O.D. Pipe) VENT MATERIAL /8" 4 /8" Front View 7 /8" 5 /8" 4" Available in pints PVDF STILE VALLEY LOSURE Side View 6 /4" Right Valley losure Left Valley losure Polyethylene Foam Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-5
6 UL 580 Wind Uplift Information 6" o.c A STILE onstruction No. 5 November, 999 Uplift - lass 90 Fire Not Investigated. Metal Roof Deck Panels* No. 26 MSG min thick coated steel. Width 9.4 in., height at ribs -/6 in. METAL SALES MANUFATURING ORPORATION - Stile 2. over Board (Optional)-/4 in. Georgia-Pacific Dens- Deck.. Underlayment 0 lb organic felt. Sides overlapped min 2 in., end laps per manufacturer s instructions. 4. Insulation* (Optional)-Any UL lassified rigid insulation, thickness not to exceed -/2 in. 5. Fasteners (Screws) Fasteners to be No. 4-4 x -/2 in., hex head, Type AB, self- tapping screws with sealing washer and painted finish. 5A. Fasteners (Rivets) Fasteners used to attach panels (Item ) at side and end laps to be /8 in. diameter by /6 in. long stainless steel pop rivets. 6. Plywood Decking Decking to be min 5/8 in. (9/2 in. actual) thick. APA 20 span rated plywood sheathing. Fastened to supports with No. 8 by 2 in. long coarse thread wood screws. All butt joints to be sealed against leakage by using tape and/or caulk or with one-part urethane sealant. 7. Supports (Joists) Spaced max 2 ft O. Graded dimension lumber, No. 2 or better. Refer to general information, Roof Deck onstruction, for Items not evaluated. *Bearing the UL lassification Marking U L Underwriters Laboratories Inc. LISTED PST-6 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
7 Section Properties and General Information 2" 2" Available in lengths up to 20'-0" 9.4" overage 42." Overall width 2" Ga. 26 Width (in.) Yield KSI 9.4" 25 Weight PSF 0.8 SETION PROPERTIES Top in ompression Ixx In 4 /ft Sxx In /ft Bottom in ompression Ixx In 4 /ft Sxx In /ft ALLOWABLE UNIFORM LIVE LOADS PSF ( or More Equal Spans) Outward Uplift (Stress) Load '-0" 2'-0" '-0" Theoretical section properties have been calculated per AISI 200 Specification for the Design of old-formed Steel Structural Members. Ixx and Sxx are effective section properties for deflection and bending. 2. Allowable load is calculated in accordance with AISI 200 specifications considering bending, shear, combined bending and shear, deflection, uplift testing, pullout from 5/8" plywood, and pullover. Allowable load considers the worst case of and 4 equal span conditions. Allowable load does not address web crippling. Panel weight is not considered.. Deflection consideration is limited by a maximum deflection ratio of L/80 of span. 4. Allowable loads do not include a / stress increase in uplift. ATTAHMENT DETAIL High end Sidelaps fastened '-0" o.c. with a /8" x /6" Pop Rivet or a /4"-4 x 7 /8" Stitch Screw FASTENING PATTERNS / 4"-4 x / 2" Woodscrew XL Stile Panel Stile losure Tube Sealant (Top and Bottom of losure) End Fastening Pattern Pop Rivet or Stitch Screw w/ Tube Sealant END FASTENING PATTERN / 8" x / 6" Pop Rivet with Tube Sealant / 4"-4 x / 2" Woodscrew XL Stile Panel Interior Fastening Pattern at every third step Low end End Fastening Pattern GENERAL INFORMATION Slope The minimum recommended slope for the Stile roof panel is :2. Substructure The recommended substrate is 5 / 8" plywood with a 0 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure. NOTE: Stile roof panels are not recommended for use over open structural framing. overage Stile panels have a coverage of 9.4" ( meter). Length factory cut panel length is '-0". Maximum panel length is 20'-0". Panel lengths are available in '-0" increments. Fasteners The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading and code requirements. NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment. Availability Finish: Kynar 500 (PVDF) colors. Gauge: 26 ga standard Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-7
8 Design / Installation onsiderations FASTENER INSTALLATION TEHNIQUE Recommended Tool Type - Use depth locating nose or adjustable clutch on screw gun to prevent overdrilling and strip out. Do not use impact tools or runners. Seating the washer - Apply sufficient torque to seat the washer - do not overdrive the fastener. ORRET Sealing material slightly visible at edge of metal washer. Assembly is watertight. TOO LOOSE Sealing material is not visible; not enough compression to seal properly. TOO TIGHT Metal washer deformed; sealing material pressed beyond washer edge. WOODSREW To prevent wobbling - Make sure fastener head is completely engaged in the socket. If the head does not go all the way in the socket - tap the magnet deeper into the socket to allow full head engagement. Metal chips will build up from drilling and should be removed from time to time. Protect drill point - Push only hard enough on the screw gun to engage clutch. This prevents excess friction and burn out of the drill point. orrect pressure will allow screw to drill and tap without binding. Drilling through sheet and insulation - Ease up on pressure when drilling through insulation to avoid striking the purlin or girt with the point - apply more pressure after drill point contacts purlin or girt. ONDITION OF SUBSTRUTURE Whether over solid substrate or open structural framing, panel distortion may occur if not applied over properly aligned and uniform substructure. The installer should check the roof deck for squareness before installing Stile panels. Several methods can be used to verify squareness of the structure for proper installation of the panels. METHOD "A" - One method for checking the roof for squareness is to measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension. METHOD "B" - The -4-5 triangle system may also be used. To use this system measure a point from the corner along the edge of the roof at a module of three (). Measure a point from the same corner along another edge at a module of four (4). Then by measuring diagonally between the two points established, the dimension should be exactly a module of five (5) to have a square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square, the roof system cannot be installed as shown in these instructions. METHOD A METHOD B PST-8 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
9 Design / Installation onsiderations (cont) VENTILATION Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency. ondensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique with metal roofing; these problems are common to all types of construction. The underside of the metal roof on a typical Architectural building should be protected from condensation by installing panels directly over a minimum 0 lb moisture barrier and uniform solid substrate. This reduces airspace and the potential of condensation forming on the underside of the panels. Vent Vent Insulation Vent at wall Vent at eave Typical metal building (no attic) Building with attic or retrofitted PANEL APPLIATIONS The following chart highlights UL 580 lass 90 for fastener spacing on the selected applications (see Fastener Selection Guide page PGI-2-4 for other fasteners available). For more information on UL onstruction numbers, refer to UL Roofing Materials and System Directories. PANEL TYPE APPLIATION INSTALLATION REQUIREMENTS FASTENER SPAING TYPE OF FASTENER NUMBER REQUIRED STILE FASTENERS OVER 5 /8" PLYWOOD DEK ONST. #5 UL GAUGE '-0" O..** /4"-4 x /2" ABMP XL - PAINTED 4 FASTENERS* * ABMP XL Fastener also available in # /4-4 x " - Painted. ** Based on UL-580. Subject to project loading, closer fastener spacing may be required. ontact your local Metal Sales branch representative for more information (see pages PGI-2-). Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-9
10 Eave Detail :2 Slope /4"-4 x /2" Woodscrew XL ('-0" o.c.) Stile Starter /6" x 6" Spacer Stile losure /4"-4 x /2" Woodscrew XL (see below) leat Eave #0-2 x " PHW ('-0" o.c.) /4"-4 x /2" Woodscrew XL STILE :2 Slope Extended Eave Detail /4"-4 x /2" Woodscrew XL ('-0" o.c.) Stile Starter /6" x 6" Spacer Stile losure /4"-4 x /2" Woodscrew XL (see below) Extended Eave #0-2 x " PHW ('-0" o.c.) leat /4"-4 x /2" Woodscrew XL PST-0 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
11 Gutter Detail :2 Slope /4"-4 x /2" Woodscrew XL ('-0" o.c.) Stile Starter /6" x 6" Spacer Stile losure /4"-4 x /2" Woodscrew XL (see below) /8" x /6" Pop-Rivet Universal Gutter / Downspout Strap Box Gutter # /4-4 x /2" Woodscrew XL STILE Valley Detail :2 Slope /8" x /6" Pop-Rivet (every other rib) /4"-4 x /2" Woodscrew XL (see below) Universal losure Valley Valley Plate /4"-4 x /2" Woodscrew XL Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-
12 Slope hange Detail :2 Slope Stile losure /4"-4 x /2" Woodscrew XL (see below) Pitch Break /8" x /6" Pop-Rivet (every other rib) Stile losure /4"-4 x /2" Woodscrew XL (see below) /4"-4 x /2" Woodscrew XL STILE Endlap Detail /4"-4 x /2" Woodscrew XL (see below) Tube Sealant (put in flats) :2 Slope 4" overlap /4"-4 x /2" Woodscrew XL PST-2 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
13 Rake Detail /8" x /6" Pop-Rivet ('-0" o.c.) Rake Rake Starter leat Fastener (by others) /4"-4 x /2" Woodscrew XL ('-0" o.c.) STILE Formed Rake Detail Formed Rake Rake Starter /4"-4 x /2" Woodscrew XL ('-0" o.c.) Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-
14 Rake Parapet Siding Detail Pitch Break Fastener (by others) Rake Starter /8" x /6" Pop-Rivet ('-0" o.c.) /4"-4 x /2" Woodscrew XL ('-0" o.c.) /4"-4 x /2" Woodscrew XL ('-0" o.c.) STILE :2 Slope Endwall with ounter Detail Tube Sealant ounter Flashing Fasteners (by others) Pitch Break /8" x /6" Pop-Rivet (every other rib) Stile losure /4"-4 x /2" Woodscrew XL (see below) /4"-4 x /2" Woodscrew XL PST-4 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
15 Endwall with Reglet Detail :2 Slope Tube Sealant Reglet Flashing Fasteners (by others) Pitch Break /8" x /6" Pop-Rivet (every other rib) Stile losure /4"-4 x /2" Woodscrew XL (see below) /4"-4 x /2" Woodscrew XL STILE Junction Sheet Detail :2 Slope Tube Sealant Fasteners (by others) ounter Flashing Junction Sheet /4"-4 x /2" Woodscrew XL (see below) /4"-4 x /2" Woodscrew XL Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-5
16 Ridge/Hip Detail :2 Slope /8" x /6" Pop-Rivet (every other rib) Stile losure /4"-4 x /2" Woodscrew XL (see below) Ridge/Hip over /4"-4 x /2" Woodscrew XL STILE :2 Slope Formed Ridge/Hip Detail /4"-4 x /2" Woodscrew XL (see below) /8" x /6" Pop-Rivet (every other rib) Stile losure / Stile Hip losure Formed Ridge/Hip over /4"-4 x /2" Woodscrew XL PST-6 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
17 :2 Slope 7 /8" Formed Vented Ridge Detail /8" x /6" Pop-Rivet ('-0" o.c.) Stile Ridge Drip Offset leat #4- x 2" ('-0" o.c.) Vent Material Vent Drip Stile losure / Stile Hip losure Formed Ridge /8" x /6" Pop-Rivet /4"-4 x /2" Woodscrew XL (see below) /4" /4"-4 x /2" Woodscrew XL STILE :2 Slope Roof Vent Detail 9 /2" /4"-4 x /2" Woodscrew XL Stile Roof Vent Stile Roof Vent 7" Stile Roof Panel Roof Opening 9 /2" x 7" Field ut Roof Opening Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ PST-7
18 Notes PST-8 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/
IMAGE II. Panel Information. Detail Conditions. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations PIM-1
Table of ontents Product Page No. Product Page No. Panel Information Profiles... PIM-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3
More informationTABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles
TABLE OF ONTENTS Product Page No. Product Page No. Panel Information Profi les...pim-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3
More informationCLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations
LIP-LO Table of ontents Product Page No. Product Page No. Panel Information lip-loc Panel Profile... PL-2 Panel Overview... PL-2 Flashing Profiles Eave... PL- leat... PL- Box Gutter... PL- Box Gutter End...
More informationDetail Conditions. Panel Information. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations PEF-1
Table of ontents Product Page No. Product Page No. Panel Information T3 Panel Profiles... PEF-2 T3 Panel Overview... PEF-2 T6- Panel Profiles... PEF-3 T6- Panel Overview... PEF-3 T- Panel Profiles... PEF-4
More informationVERTICAL SEAM TABLE OF CONTENTS
TABLE OF ONTENTS Product Page No. Product Page No. Panel Information Vertical Seam Panel Profi les... PVS- Panel Overview... PVS- Flashing Profiles Eave... PVS- Extended Eave... PVS- leat... PVS- Offset
More informationPrior to ordering and installing materials, all dimensions should be verified by field measurements.
Important Information The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects
More informationPBR & PBU PANELS. Technical/Installation Information
PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE PANEL S. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS A MINIMUM
More information* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.
is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.
More informationStile. Spanish Tile Installation Guide
Stile Spanish Tile Installation Guide IMPORTANT INFORMATION THE APPLICATION AND DETAIL DRAWINGS IN THIS MANUAL ARE STRICTLY FOR ILLUSTRATION PURPOSES AND MAY NOT BE APPLICABLE TO ALL BUILDING DESIGNS OR
More informationSEAM-LOC 24. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles
Table of ontents Product Page No. Product Page No. Panel Information Seam-Loc 24 Panel Profile...PSL-2 Panel Overview...PSL-2 Flashing Profiles Seam-Loc 24 Sculptured Eave...PSL- Seam-Loc 24 Sculptured
More information5V Crimp DESIGN/INSTALLATION INFORMATION
5V Crimp DESIGN/INSTALLATION INFORMATION IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SYSTEM. METAL DEPOTS DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE
More informationPBR & PBU PANELS. Technical/Installation Information
PBR & PBU PANELS Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Retro-R PANELS. THE MANUFACTURER DETAILS MUST BE FOLLOWED AS
More informationTable of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5
Table of Contents Section Page Notes to Designer/User...................1-2 Map of Typical Roof Conditions..............3 Fastener Placement........................4 Fastener Selection.........................5
More informationSHURLOC 150 STANDARD DETAILS
OVER WOOD DECK STANDARD DETAILS Austin - Headquarters/Sales Office 830 Sagebrush Drive Austin, TX 78758 (512) 452-1515 (800) 428-7412 Fax (512) 833-7499 www.ctmrs.com email: info@ctmrs.com Seguin - Plant/Sales
More informationEVERSEAM 20 APPLICATION GUIDE
EVERSEAM 20 APPLICATION GUIDE Panel Overview Our Name Says It All!"#$%#&'()*+,!"#$%#&'(-.( Applications: The EverSeam panel is an architectural panel that is ideal for residential and light commercial
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial
More informationPBR & PBU Panels. Technical/Installation Information
PBR & PBU Panels Technical/Installation Information TABLE OF CONTENTS A. PBR Panel 1. General Description..................................................................... 2 2. Architect/Engineer Information............................................................
More informationSSL-175. Specifications
SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES
More informationDL-200. Specifications
DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01
More informationTYPICAL ROOF CONDITION LAYOUT
FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/
More informationSECTION METAL ROOF AND SOFFIT PANELS
Metal Panel Systems, Inc. 11506 Reading Road Cincinnati, Ohio 45241-2512 Telephone: 800-554-6126 or 513-554-6120 Fax: 513-554-6121 www.metalpanelsystems.com info@metalpanelsystems.com Specifications for
More informationWestern States 7/8 Corrugated
Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key
More informationIMPORTANT INFORMATION
IMPORTANT INFORMATION The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects
More informationWESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.
WESTERN RIB Installation, Flashings & Shop Drawing Detail Guide 901 W. Watkins Street Phoenix, AZ 85007 Phone: (877) 787-5467 (855) 426-7836 Email: sales@cortenroofing.com sales@metalforroofing.com For
More informationML200 Panel Technical Data Guide
Description ML200 is a mechanical seamed standing seam roofing panel used on low to steep sloped commercial applications. The panel is factory formed in continuous lengths up to 60-0 long. Attachment to
More informationR PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.
R PANEL / PBR PANEL Installation, Flashings & Shop Drawing Detail Guide 901 W. Watkins Street Phoenix, AZ 85007 Phone: (877) 787-5467 (855) 426-7836 Email: sales@cortenroofing.com sales@metalforroofing.com
More informationRoofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions
Roofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions 1974 Livengood Ave Fairbanks, AK 99701 907-479-6002 allsteel.info@gmail.com Roof Installation
More information1.5 mechanical lock ml 150
1.5 mechanical lock ml 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings Max 16 Steel.0225 to.0336 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX554 The Mechanical
More informationT-Armor Install Guide
T-Armor Install Guide The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. All projects
More informationw w w. s a q u l i t y m e ta l s. c o m
san antonio branch 210 W. Peden San Antonio TX 78204 P. (210) 227-7276 F. (210) 227-0329 MCALLEN branch 2221 Austin Ave McAllen TX 78501 P. (956) 627-2966 F. (956) 627-0918 w w w. s a q u l i t y m e ta
More informationIMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.
IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY WHIRLWIND BUILDING
More informationRESIDENTIAL LIGHT GAUGE APPLICATION GUIDE
Our Name Says It All RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE Lebanon, PA 888.339.0059 Bridgton, ME 800.677.2060 Howe, IN 866.562.3782 www.everlastroofing.com Residential Light Gauge Table of Contents
More informationTable of Contents. 3. Exposed Fastener Panels
Table of Contents 895 North Parkway 3. Exposed Fastener Panels Exposed Fastener Panels Table of Contents... PE1-2 PBR... PE3-4 PBA... PE5-6 AVP... PE7-8 PBU... PE9-10 PBC... PE11-12 PBD... PE13-14 7.2...
More informationCONTOUR CORRUGATED PANEL
CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details
More information900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900
CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900
More informationTABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB
PRODUCT CATALOGUE www.metroll.us sales@fontana.metroll.com ph. 909.823.7663 fax 909.693.5153 TABLE OF CONTENTS OVERVIEW PBR Product Overview and Color Charts Panel Information and Trim 7.2 LONGSPAN ECONORIB
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. COMMERCIAL RESIDENTIAL AGRICULTURAL MS-216 MS-218 Panel Guide This guide describes the design and performance characteristics of the MS-216 and MS-218 Roof panel system. The
More informationInstallation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile
Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME MATTERHORN Tile Watch detailed installation videos online at matterhornmetalroofing.com/tile-installation Table of Contents Accessories: Most
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationCentral Snap. Condition Details C SNAPDETAILS
Central Snap Condition Details D C SNAPDETAILS150612.2 The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing, Inc. is a 100% employee-owned
More information1.5 mechanical lock ml 150
1.5 mechanical lock ml 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings Max 16 Steel.0225 to.0336 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX554 The Mechanical
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More information1.5 snap lock sl 150
1.5 snap lock sl 150 Strip Width Base Material Thickness Min Tensible Min Yield Coatings 12.00 to 24 Steel.0128 to.027 in 52 - ksi 50 - ski Painted / Galvalume UL CONSTRUCTION NUMBERS: TGKX301, tgkx342a,
More information2120 SW Poma Drive; Palm City, Florida Phone Fax
2120 SW Poma Drive; Palm City, Florida 34990 772-223-4055 Phone 772-781-7492 Fax www.sunlastmetal.com sales@sunlastmetal.com IMPORTANT NOTICE READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF
More informationENERGY STAR PARTNER. PBR & R Panel
ENERGY STAR PARTNER 1 Table of Contents Important Information Installation Information Technical Information Trims and Flashings Illustration Roo ng Installation Details Eave Flashing (EF-3) Eave Flashing
More informationCOMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER
CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER CI-CFR-LG LEGEND CI-CFR-JT-01 PANEL JOINT CI-CFR-JT-02 PANEL JOINT SEQUENCE CI-CFR-JT-03 PANEL JOINT LAYOUT CI-CFR-SQ-01 PANEL INSTALLATION SEQUENCE
More informationCentral Seam Plus. Central-Loc
Central Seam Plus Central-Loc Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES 3" 3" " or 18" COVERAGE " or 18" COVERAGE Central Seam Plus Field seamed Central-Loc Snaps together
More informationNUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS
NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationML-150. w w w. s a q u l i t y m e ta l s. c o m. san antonio branch 210 W. Peden San Antonio TX P. (210) F.
ML-150 san antonio branch 210 W. Peden San Antonio TX 78204 P. (210) 227-7276 F. (210) 227-0329 MCALLEN branch 2221 Austin Ave McAllen TX 78501 P. (956) 627-2966 F. (956) 627-0918 w w w. s a q u l i t
More informationSL-16. Design/Installation Information
SL-16 Design/Installation Information IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SL Series ROOFING SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More informationClassic Rib Roofing Panels DETAIL MANUAL
Metal Roofing Wholesalers Classic Rib Roofing Panels DETAIL MANUAL www.metalroofingwholesalers.com 1170 Topside Rd Louisville, TN 37777 The Classic Rib Roofing Panel Figure 1 House With Classic Rib Metal
More informationa division of NCI Standing Seam Roof Systems
a division of NCI Standing Seam Roof Systems Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per square foot. When long life is required
More information2120 SW Poma Drive; Palm City, Florida Phone Fax
2120 SW Poma Drive; Palm City, Florida 34990 772-223-4055 Phone 772-781-7492 Fax www.sunlastmetal.com sales@sunlastmetal.com IMPORTANT NOTICE READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF
More informationBlack s Metals Installation Guide
Storage Black s Metals Installation Guide If metal is not to be used immediately, store inside in a well ventilated, dry location. Condensation or other moisture can form between the sheets during storage
More informationUNA-CLAD Metal Roof Systems Code Approval Guide
UNA-CLAD Metal Roof Systems Code Approval Guide You must verify the included assemblies in the charts below with the associated Firm s (UL, FM, etc). t all of the information included in the RoofNav assemblies
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 NOTICE OF ACCEPTANCE
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com Page2 INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationResidential Pricing Guide
Guide TABLE OF CONTENTS Panels 5V Crimp Slimline 2 4 Accessories Flat Sheets Coils V-Groove Soffit Ridge Caps Roof Jacks Touch-up Paint Insulation Slimline Rib Cover Closure Strips Tube Sealant 6 6 7
More informationSHEET METAL ROOF TEST REPORT
SHEET METAL ROOF TEST REPORT Introduction The time tested performance of the double lock standing seam and batten seam metal roofing is demonstrated by thousands of squares successfully installed by SMACNA
More informationSECTION METAL ROOF PANELS
SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof
More informationw w w. s a q u l i t y m e ta l s. c o m
san antonio branch 210 W. Peden San Antonio TX 78204 P. (210) 227-7276 F. (210) 227-0329 MCALLEN branch 2221 Austin Ave McAllen TX 78501 P. (956) 627-2966 F. (956) 627-0918 w w w. s a q u l i t y m e ta
More informationINSTALLATION GUIDE.
INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More information238T Aluminum Standing Seam Metal Roof System (SSMRS)
238T Aluminum Standing Seam Metal Roof System (SSMRS) Text in red are instructions to the specifier and should be deleted. Text in blue are choices that need to be made, with those not selected, deleted.
More information3' COMMERCIAL RIB PREFORMED METAL SIDING
SECTION 07410 3' COMMERCIAL RIB PREFORMED METAL SIDING PART 1 GENERAL 1.01 DESCRIPTION A. Work in this section includes furnishing and installation, preformed steel ribbed siding on vertical portions of
More informationSL175 Panel Technical Data Guide
Description SL175 is a integral snap-lock standing seam roofing panel used on commercial and residential applications. The panel is factory formed in continuous lengths up to 60-0 long. Attachment to either
More informationDrexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood
Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
More informationClassic and NB Tile Counter Batten and Batten
Classic and NB Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationTrusted Tested Tough Kalaeloa Blvd, Kapolei, Hawaii Phone (808) Fax (808) Neighbor Islands (800)
MAC 200 STRUCTURAL STANDING SEAM METAL ROOF SYSTEM Trusted Tested Tough 91-104 Kalaeloa Blvd, Kapolei, Hawaii 96707 Phone (808) 682-3000 Fax (808) 682-3636 Neighbor Islands (800) 352-3920 www.kloecknermetals.com
More informationBARREL VAULT Tile Counter Batten and Batten Installation Guide
BARREL VAULT Tile Counter Batten and Batten Installation Guide www.boral.com Page2 BARREL VAULT Tile Actual Size= 43 13/16 x 15 5/8 Exposure= 43 1/4 x 14 Weight= 5.4lbs. per panel Panels per square (100
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationALLMET CONTINENTAL INSTALLATION GUIDE
ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental
More information5V CRIMP. Technical/Installation Information
5V CRIMP Technical/Installation Information IMPORTANT NOTICE READ THIS MANUAL OCMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE SYSTEM. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE
More informationCovering Design Regions
Covering Covering Design Regions Roof Covering Roof Covering (SSR) 24 coverage w/ 3 seam height Machine seamed, in-place Attached to roof secondary (purlins, widebay truss purlin or bar joist) w/ a concealed
More informationCS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
More informationSheet Metal Flashing and Trim
University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 076200 - Sheet
More informationHORIZON-LOC EXPOSED FASTENER TRIMS
Horizon -Loc Horizon-Loc is available in 6ga AZ50 painted Galvalume and bare Galvalume. Central States uses either the CentralGuard or Kynar 500 /Hylar 5000 paint system on all painted metals. Bare (non-painted)
More informationResidential, 26 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D
Product Evaluation Report REED S METAL, INC. Residential, 26 Ga. Roof Panel over 15/32 Plywood Florida Product Approval # 12725.2 R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D Category: Roofing
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590
More informationT-Rib Roofing System
T-Rib Roofing System Installation Manual 3449 Hempland Road Lancaster, PA 17601 (717) 397-2741 308 Alabama Blvd. Jackson, GA 30233 (770) 775-4484 World Wide Web: www.fabral.com E-Mail: fabinfo@fabral.com
More informationS BI COM P ON E NT CA T ALOG
SBI METAL BUILDINGS & COMPONENTS S BI COM P ON E NT CA T ALOG Date: 03 / 16 / 2017 COMMERCIAL PRODUCTS Commercial Panels and Trim Cee, Zee, Eave Struts, Angle, Channel, and Clips Accessories FT 0 1 2 3
More informationTable of Contents. 3. Standing Seam Panels
Table of Contents 895 North Parkway 3. Standing Seam Panels Standing Seam Panels Table of Contents... PS1-2 Double-Lok... PS3-8 Ultra-Dek... PS9-14 BattenLok HS... PS15-18 Curved BattenLok HS... PS19-20
More informationLight-Metal Roof Edge, Raised
NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED
More informationPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationUNA-CLAD Metal Roof Systems
UNA-CLAD Metal Roof Systems Underwriters Laboratories (UL) UL Roof Deck Constructions and P Assemblies Factory Mutual Approvals (FM) Table of Contents 1.01 EXTERNAL FIRE RATINGS... 7 Assemblies are updated
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationPIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components
Central Texas Largest Distributor Structural Steel, Pipe and Metal Building Components PIPE Waco Location P.O. Box 154485 913 South Loop Dr. Waco Texas 76705 Local - 254-754-2611 Bryan Location 9401 E.
More informationOSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS
OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural roofing system of preformed steel panels. B. Fastening system. C. Factory finishing. D. Accessories and miscellaneous components.
More informationGuide Specifications ADP Series SECTION SHEET METAL ROOFING
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]
More information1 1/2" SSR. FABRAL The pursuit of excellence since 1967
1 1/2" SSR Detail Manual and Estimate Guide 16" 1 1 2" PROPER STORAGE When moisture remains in contact with Galvanized panels in the absence of freely circulating air, white, black or dark gray corrosion
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationFABRAL The pursuit of excellence since 1967
1 1/2" SSR Detail Manual and Estimate Guide 16" 1 1 2 " PROPER STORAGE When moisture remains in contact with Galvanized panels in the absence of freely circulating air, white, black, or gray corrosion
More informationPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationSECTION STEEL BUILDING SYSTEMS
PART 1 - GENERAL 1.01 SECTION INCLUDES: SECTION 13120 - STEEL BUILDING SYSTEMS A. Pre-engineered building and components including the following: 1. Structural steel frame. 2. Roof covering system including
More informationRecla Metals RCM INSTALLATION GUIDELINES
Recla Metals RCM INSTALLATION GUIDELINES Caution: RCM roofing panels must be applied on a minimum roof pitch of 2½:12 or greater. Important Notice: This guide must by read in its entirety before beginning
More informationPRE-ENGINEERED METAL BUILDING SYSTEM
PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,
More information