ELEVATION FOR DETAIL REFERENCE ONLY
|
|
- Phyllis Holmes
- 6 years ago
- Views:
Transcription
1 SOFFIT OUTSIDE CORNER OPENING 11 END WALL INSIDE CORNER ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX STANDARD PANEL OFFERING SIDE LAP DETAILS WALL SECTIONS WALL SECTIONS WALL SECTIONS BASE DETAILS PARAPET DETAILS END LAP DETAILS HEAD OPENING DETAIL IWV-11 SILL OPENING DETAIL IWV-12 JAMB OPENING DETAIL IWV-1 HEAD, JAMB, SILL INTERSECTION IWV-1 END WALL DETAIL IWV-15 SOFFIT DETAILS IWV-16 OUTSIDE CORNER DETAIL IWV-17 INSIDE CORNER DETAIL IWV-18 PENETRATION (1 of 2) IWV-19 PENETRATION (2 of 2) INDEX NOTE: DETAILS ARE FOR PROMOTIONAL USE ONLY. FOR COMPLETE DETAILS, REFER TO CENTRIA'S WEB SITE AT IWV-01
2 [05] [05] " [8] " [8] " 6" [152] " [05] IW-10A [05] IW-11A " 1 2 " " " [8] " [8] [96] [11] [96] [05] IW-12A [05] IW-1A 6" [152] 6" [152] " [8] " " " " " [8] [05] IW-1A [05] IW-15A 6" [15] [05] 6" [15] IW-20A " [8] " 6" [15] " 6" [15] IW-21A [05] " " " [8] 2" [9] 10" [256] IW-0A [05] " [8] 2" [9] " " [102] 10" [256] IW-1A [05] " " [8] 1" [2] 11" [281] IW-0A " [8] 1" [2].667 [9].667 [9] 11" [281] IW-1A.667 [9] " [8] IWV-02 Jan. 1
3 NON-CURING BUTYL [05] NOMINAL COVERAGE NON-CURING BUTYL [05] NOMINAL COVERAGE NON-CURING BUTYL [05] NOMINAL COVERAGE NON-CURING BUTYL IW-10A, IW-11A, IW-12A, IW-1A, IW-1A, IW-15A 6" 2" " 11 2 " 11 2 " 11 2 " IW-20A, IW-21A IW-0A, IW-1A [05] NOMINAL COVERAGE 1" SIDE LAP DETAILS IW-0A, IW-1A IWV-0
4 DRAINED & VENTED CAVITY IW SERIES PANEL INTERIOR SHEATHING STUD INSULATION EXTERIOR SHEATHING HORIZONTAL /" [19] DEEP 16 GA. SUBGIRT BARRIER PANELS ON PROTECTED EXTERIOR SHEATHING WITH CAVITY INSULATION VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. DRAINED & VENTED CAVITY IW SERIES PANEL HORIZONTAL 1/2" [1] DEEP 16 GA. SUBGIRT HORIZONTAL GIRTS BARRIER (PROVIDED BY FACE PANEL) VERTICAL LINER PANEL WITH FACTORY APPLIED SEALANT AIR BARRIER (LINER PANEL) FIELD-APPLIED (1.65 PCF) INSULATION IN LINER CAVITY PANELS WITH INSULATION IN VERTICAL LINER IWV-0 Aug. 11
5 IW SERIES PANEL " DRAINED & VENTED CAVITY "A" "A" METALWRAP INSULATED BACK-UP PANEL METALWRAP INSULATED BACK-UP PANEL METALWRAP CONT. ZEE AT EACH PANEL SIDE JOINT (6" O.C.) IW SERIES PANEL SECTION A-A PANELS WITH METALWRAP INSULATED BACK-UP PANEL DRAINED & VENTED CAVITY IW SERIES PANEL INTERIOR SHEATHING STUD CON'T. HORIZONTAL ZEE 16 [1.52] GA. MIN. (SPACING TO BE DETERMINED BY CLADDING ENGINEER) EXTERIOR SHEATHING BARRIER INSULATION SUITABLE FOR MOISTURE EXPOSURE PANELS WITH INSULATION OUTBOARD OF STUD CAVITY VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. IWV-05 Aug. 11
6 MASONRY FASTENER (*) CONTINUOUS HORIZONTAL ZEE SHAPED SUBGIRT (SHIM AS REQUIRED) (*) SUBGIRTS SHALL BE 1.) 16 GA. MINIMUM. 2.) /" [19] MINIMUM DEPTH..) SPACED AT 2" [610] OR 8"O.C. [1219] BASED ON DESIGN LOADS AND INSULATION SIZE. MASONRY INSULATION SUITABLE FOR MOISTURE EXPOSURE AIR BARRIER & WATER RESISTANT COATING OR MEMBRANE IW SERIES PANEL DRAINED & VENTED CAVITY PANELS WITH INSULATION OVER MASONRY WALL VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. IW SERIES PANEL HORIZONTAL GIRTS FINISH IS REQUIRED ON BOTH SIDES OF THE PANEL SINCE BOTH SIDES ARE EXPOSED TO THE WEATHER PANELS USED AS A SCREEN WALL IWV-06 Aug. 11
7 EXTERIOR SHEATHING BARRIER SELF ADHERING TAPE " [19] SUBGIRT DESIGN OF BASE MUST VARY TO SUIT CONCRETE PLACEMENT AND FORMING TOLERANCES STUDS EXTERIOR SHEATHING BARRIER SELF ADHERING TAPE " [19] SUBGIRT 1 8 "[] GAP 1"[25] B/FLASH "± 1 " 1 8 "GAP T/CURB BASE DETAILS IWV-07
8 F/PNL 5 SLOPE 2"[51] MIN. NON-CURING BUTYL METAL CLOSURE AS REQUIRED EXTERIOR SHEATHING STUDS BARRIER " [19] SUBGIRT PARAPET IWV-08 Aug. 11
9 EXTERIOR SHEATHING BARRIER AND AIR BARRIER 2"[51] SWAGE NBC NON-CURING BUTYL " [19] SUBGIRT END LAP NOTE: 1.) SHOP SWAGED ENDS ARE NOT AVAILABLE FOR 18 GAGE [1.19MM] PANELS. 2.) SHOP SWAGED ENDS ARE NOT AVAILABLE FOR IW-12A, IW-1A, AND IW-15A. IWV-09
10 EXTERIOR SHEATHING BARRIER SELF ADHERING TAPE " [19] SUBGIRTS STUDS DOOR, WINDOW OR LOUVER PRIMARY AIR SEAL 1 8 " [] GAP WEATHER SEAL HEAD OPENING IWV-10
11 T/PNL 1/2" [1] CLR. STUDS " [19] SUBGIRT EXTERIOR SHEATHING METAL CLOSURE AS REQUIRED BARRIER SILL OPENING IWV-11
12 STUDS BARRIER AND AIR BARRIER EXTERIOR SHEATHING R.O. BARRIER PRIMARY AIR SEAL PER MANUFACTURER RECOMMENDATIONS CURING BUTYL DOOR, WINDOW OR LOUVER WEATHER SEAL /" [19] SUBGIRT 1 1/2" DEEP SUBGIRT (SG ) JAMB OPENING IWV-12 Aug. 11
13 INTERSECTION OF HEAD, JAMB & SILL FLASH (IWHZ-2016) IWV-1
14 BARRIER AND AIR BARRIER STUDS EXTERIOR SHEATHING "[19] SUBGIRT SELF ADHERING TAPE 1 1/2" DEEP SUBGIRT (SG ) POLYURETHANE 1 2 " [1] F/CONC. END WALL IWV-1
15 SELF ADHERING TAPE " [19] SUBGIRT EXTERIOR SHEATHING BARRIER NON-CURING IW-10A OR IW20,0, &0 1/2" [1] E/PNL CLR. SOFFIT - FRONT NON-CURING IW-10A OR IW20,0, &0 E/PNL 1" [25] CLR. NO IW-10A & METAL CLOSURE@ IW20,0, &0 " [19] SUBGIRT EXTERIOR SHEATHING BARRIER SOFFIT - BACK IWV-15
16 BARRIER AND AIR BARRIER EXTERIOR SHEATHING STUDS " [19] SUBGIRT USE A /16"[5]x"x" SHIM UNDER MALE LEG OF PANEL AT EACH FASTENING POINT TO MAINTAIN ALIGNMENT OF PANEL FACE (IF REQUIRED). SG SUBGIRT CONTINUOUS (TYP.) OUTSIDE CORNER IWV-16 Jan. 1
17 BARRIER AND AIR BARRIER EXTERIOR SHEATHING SG SUBGIRT CONTINUOUS (TYP.) STUDS " [19] SUBGIRT USE /16"[5]x"x" SHIM UNDER MALE LEG OF PANEL AT EACH FASTENING POINT TO MAINTAIN ALIGNMENT OF PANEL FACE (IF REQUIRED). INSIDE CORNER IWV-17 Jan. 1
18 NOTE: REF. PAGE IWV-19 FOR SECTS. A-A & B-B PENETRATION DETAIL (1 OF 2) IWV-18 Jan. 1
19 G.L. NON-CURING BUTYL FLAT SUPPORT FLASH SECTION A-A SUPPORT FLASH FLAT POLYURETHANE (TYP. ALL AROUND) SECTION B-B PENETRATION DETAILS (2 OF 2) IWV-19
ELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08
More informationELEVATION FOR DETAIL REFERENCE ONLY
8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05
More informationELEVATION FOR DETAIL REFERENCE ONLY
4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS
More information12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS
CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL
More informationFACE CFP - HORIZONTAL PANELS - OPTION 'B'
- Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF
More informationELEVATION FOR DETAIL REFERENCE ONLY
#smr_elev 5b SEC 2 8i SEC 2 33 SEC 4 1a SEC 2 37 SEC 4 36 SEC 4 35 SEC 4 SOFFIT FRONT 6d SEC 2 7a SEC 2 SOFFIT REAR INSIDE CORNER (REAR) OUTSIDE CORNER (FRONT) 10a SEC 2 9b SEC 2 4e SEC 2 ELEVATION FOR
More informationCENTRIA Concept Series Metal Wall Panels ZINC
CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles and five
More informationMR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA
Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition
More informationSECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES
SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.
More informationWeatherSmart Air Barrier Installation Guide
WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More informationCOMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE
COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM
More informationGAF EnergyGuard Polyiso Wall Sheathing
From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:
More informationSECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
SECTION 07 42 13.01 METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 620 AAMA 621 Voluntary Specification for High Performance Organic Coatings
More informationPella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...
SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood
More informationCENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System
CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre is a unique modular metal wall system designed, available from a reliable national manufacturer and supported
More informationCentria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
SECTION 07 42 13.03 METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 620 AAMA 621 Voluntary Specification for High Performance Organic Coatings
More informationCENTRIA FORMABOND II Metal Composite Wall System
CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FormaBond II is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer
More informationCENTRIA FORMABOND. Aluminum Composite Wall System
CENTRIA FORMABOND Aluminum Composite Wall System CENTRIA FormaBond is the only true aluminum composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer
More informationSchedule A Development Permit No Issued this 18 day of April, 2018
Schedule A Development Permit No. 001610 Issued this 18 day of April, 2018 N No. Revision/Issue Date MM/DD/YY 1 ISSUED FOR TENDER 10/26/17 LEGEND: WORK AREA VILLAGE STROLL VILLAGE GREEN SOUTH WING 1 0
More informationHow do you install yours?
How do you install yours? Darrell Paul Qualistat Building Performance Consultants CSA 440 Just about adding Peel & Stick? 1 Window and door problems Photos / videos Video available for viewing at INSTAGRAM
More informationProper Installation of Insulated Metal Wall Panels
Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also
More informationGuide Specification for the OSI QUAD Window and Door Flashing System
Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL
ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties
More informationKARRIER PANEL - BRICK
KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK
More informationCENTRIA Concept Series TM Metal Wall Panels
CENTRIA Concept Series TM Metal Wall Panels CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles, metal substrates,
More informationPrestige Series 12. Installation guide
Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................
More informationPanel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing
EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing
More informationMagnum Board Coatings
Master Wall Mesh and Base Coat Plastic Control Joint Accessory, Plastic Components 22027-16 or equal. See notes for placement recommendations Notes: Control joints are required and should be located by
More informationCowhorn Residence. PHnw 2017 Cowhorn Residence
Cowhorn Residence LEARNINGOBJECTIVES Course Approved for CPHC Continuing Education Credits 1. Learn how to orient buildings based on site conditions and owner criteria 2. Understand the impact of site
More informationCONTOUR CORRUGATED PANEL
CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT
SECTION 04110 MORTAR AND MASONRY GROUT PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. In the absence of other information, the methods and recommendations of the National Concrete Masonry Association
More informationWrapShield SA Brick Tie Penetration
Brick Tie Penetration Outboard Vapor - Pemeable Insulation WrapShield SA Self-adhered WRB/AB field membrane Brick Tie must be Flush and compressed against Membrane with no prong penetrations Gasketed Fastener
More informationSC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish
Master Wall Mesh and Base Coat Plastic Control Joint Accessory, Plastic Components 22027-16 or equal. See notes for placement recommendations Notes: Control joints are required and should be located by
More informationCENTRIA MetalWrap Insulated-Composite Backup Panel System
CENTRIA MetalWrap Insulated-Composite Backup Panel System CENTRIA MetalWrap Insulated Composite Backup Panel System is designed to be used with CENTRIA metal wall panel cladding to create a complete rainscreen
More informationSTRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details
STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C Stratum Guard I and II System Installation Details Stratum Guard I and II DETAIL Table of Contents NOTE SG.0.0.01 SG.0.0.02
More informationSECTION SELF-ADHERING SHEET FLASHING
MANUFACTURER S GUIDE SPECIFICATIONS SECTION 076526 SELF-ADHERING SHEET FLASHING 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 604129 03.24.15 Carlisle, Flexphalt, Sure-Seal and CAV-GRIP
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationCENTRIA Exposed Fastener Series Metal Wall Panels
CENTRIA Exposed Fastener Series Metal Wall Panels CENTRIA Exposed Fastener Series Metal Wall Panels are a versatile design choice for both new and retrofit projects. Exposed Fastener Metal Wall Panels
More informationPebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation
More informationMulti-Institutional Academic Health Science & Research Center Evansville, IN
SECTION 061600 - SHEATHING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationCommercial Flashing Details
This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from
More informationAmeriplate. Rain Screen Wall System
Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the
More informationENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL
ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties
More informationBuilding Envelope Enclosures That Work, What Owners Want!
WEBINAR February 23, 2017 Building Envelope Enclosures That Work, What Owners Want! Will Ikerd, P.E. (TX), LEED AP Webinar Speakers Karl Strand President of Vertical Solutions Consulting Will Ikerd, PE
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More informationNFPA 285 Assemblies. Table of Contents
Effective 12/16/2014 Supersedes all previous versions NFPA 285 Assemblies The following Henry assemblies meet the performance requirements of NFPA 285 as required by the International Building Code (2003,
More informationPROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS
SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
More informationArcwall. Rain Screen Wall System
Rain Screen Wall System is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines excellent performance
More informationDuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2
DuPont Tyvek Air Barrier Installation Guidelines Helping you get the job done right Canadian Version Version 2 Table of Contents Applicable Products...2 Required Materials...2 Code Requirements...3 General
More informationGA APPLICATION OF GYPSUM SHEATHING
1. Scope 1.1 This specification describes the minimum requirements for, and the methods of handling, storage, and application of, gypsum sheathing for use as a substrate for exterior claddings. 1.1.1 Exterior
More informationSenergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board
Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an
More informationDuPont RainVent Batten Installation Guidelines
DuPont RainVent Batten Installation Guidelines Purpose: To improve the ventilation and draining space behind a cladding system or 3-coat stucco system in residential construction. The DuPont RainVent Batten
More informationWall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3" = 1'-0"
Thermafiber "RainBarrier 45" Nvelope "NH2" Bracket Adapter Nvelope Wall Bracket (90mm or as Req'd) ACM Metal Panel System Metal Panel Extrusion per ACM Manufactuer 1 2 " Self-Drilling Stainless Steel Fastener
More informationDow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green
Silicone Air Barrier System of shade energy-efficient A more green Air and Moisture Protection for More Energy-Efficient Buildings Meeting regulatory requirements for energy efficiency is a significant
More informationSRP-AirOutshield UV Issued:
SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing
More informationAqua Coast Engineering
Aqua Coast Engineering Ltd. P.O. Box 1367 Station A Delta, B.C. V4M 3Y8 Tel: (604)948-0958 Fax: 604)948-0959 September 1, 2011 Matthew Cheng File#:11145 Matthew Cheng Architect Inc. Fax: 604-731-3908 Unit
More informationARCHITECTURAL DESIGN GUIDE
HPCI BARRIER TM INSULATED METAL PANEL ARCHITECTURAL DESIGN GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY TABLE OF CONTENTS INTRODUCTION...6 RAINSCREEN WALL
More informationEclipse Energy Guard. Product Information & Installation Manual General Installation Requirements
Product Information & Installation Manual 01 Important Notice to Buyers and Users of RoyOMartin wall system These instructions are not intended to cover every installation requirement, application, detail
More informationAcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details
Typical Details AcroWall-ES System Class PB Exterior Insulation and Finish System providing a primary moisture barrier 1. Typical AcroWall-ES System Application 2. Typical Aesthetic Reveal 3. Typical Window
More informationRESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide
RESIDENTIAL INSULATED SHEATHING TM COMFORTBOARD 80 Installation Guide Table of Contents Introduction How to Use this Guide...1 Split-Insulation Wall Assembly...2 Insulation... 3 Nominal and Effective R-Values
More informationKNIGHT WALL SYSTEMS GUIDE DETAILS:
KNIGHT WALL SYSTEMS GUIDE DETAILS: HCI System RAINSCREEN ATTACHEMNT HORIZONTAL ORIENTED GIRT VERTICAL PanelRail & RevealRail SYSTEM DEPTH: 1.5 INCHES (FACE OF RIGID INSULATION TO FACE OF RAIL) QUICK LINK:
More information7.0 - EXAMPLE DETAILS
7.0 - EXAMPLE DETAILS The drawings represented herein are believed to be accurate and conforming to current design and construction practices. However, the drawings should be used as a reference guide
More informationMetafor Panel System Installation Guide
Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE
More informationPROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA
The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending
More information200 / 300 SERIES PANELS COLD STORAGE
CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES
More informationProduct and System Specifications DuPont Flashing Systems
DuPont Building Innovations March 2007 4417 Lancaster Pike Chestnut Run Plaza 721 Wilmington, DE 19805 1-800-448-9835 www.construction.tyvek.com Product and System Specifications DuPont Flashing Systems
More informationWEIGHT PER PIECE (LBS.)
PRODUCT DESCRIPTION DATA SHEET 04 73 19-US BASIC USE ProGUARD DP is intended to be installed over sheathing and waterproofing over steel or wood studs or over concrete masonry units or poured concrete
More informationCode Compliance Research Report CCRR-0231
Code Compliance Research Report CCRR-0231 Issue Date: 09-01-2015 Revision Date: 10-01-2018 Renewal Date: 09-01-2019 DIVISION: 09 00 00 FINISHES Section: 09 24 00 Portland Cement Plastering REPORT HOLDER:
More informationapplication instructions
application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds
More informationPART 1 - GENERAL PROJECT NAME SECTION VAPOR PERMEABLE AIR BARRIER
SPEC WRITERS NOTE: This specification includes materials and installation procedures for WrapShield SA Self-Adhered Water-Resistive Vapor Permeable Air Barrier Sheet Membrane meeting ASTM E 2357 for air
More informationSUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:
IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:
More informationGeneral. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings
application instructions STRAND SUBSTRATE 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH General At the time of manufacture, siding meets or exceeds the performance standards
More informationProject Name Project # Project Information
SECTION 074229.00 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationWHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.
WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. Build walls and ceilings with a strong base, sturdy reinforcements and much more with Phillips extensive line of high quality products. As a single source
More informationNCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00
More informationInsulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS
Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage
More informationTABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers
version 2.5 updated as of 08.04.2017 2 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers 2.0 ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation
More informationDetail Drawings THE BEST PANEL COMPANY. from. 126 Old Highway 60 East Hardinsburg, Kentucky Office:
Detail Drawings from Rev. 4/2017 126 Old Highway 60 East Hardinsburg, Kentucky 40143 Office: 270-788-3535 www.bestpanelcompany.com Dri-Plane screen / similar / Similar Non-Corrosive Fastener designed to
More informationBUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3
PART 1 GENERAL BUILDING ENVELOPE DESIGN GUIDELINES 1.01 INTRODUCTION A. This is a guideline on the Owner s minimum standards for: 1. Masonry Division 04 2. Copings Division 04 or 07 3. Cavity wall flashings
More informationWARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationNational Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].
National Master Specification (NMS) Section 07 21 16 BLANKET INSULATION Publisher: Spex.ca Page 1 Approved: 2014-12-31 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section [ ]. 1.2 REFERENCES.1 CSA Group.1
More informationtypical section 1:50 Important:
00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of
More informationUltra Wall System. CAD Detail Sets
Ultra Wall System CAD Detail Sets Contents Page UWS-CM CAVITYMATE Ultra Contents 1-0 FOR: Details continuing on 1-1 thru 1-17 Cavity cut XPS board to fit between ladder tie masonry ties in CMU walls UWS-SL
More informationNFPA 285 Assemblies. Table of Contents
Effective 1/7/2014 Supersedes all previous versions NFPA 285 Assemblies The following Henry assemblies meet the performance requirements of NFPA 285 as required by the International Building Code (2003,
More informationKNIGHT WALL SYSTEMS GUIDE DETAILS:
KNIGHT WALL SYSTEMS GUIDE DETAILS: HCI System (HORIZONTAL HCI-Girt ) for CLADDING PANELS HORIZONTAL ORIENTED GIRT ONLY SYSTEM DEPTH: 0.75 INCHES (FACE OF RIGID INSULATION TO FACE OF RAIL) QUICK LINK: SECTION
More informationSECTION STAINLESS STEEL WALL PANELS
SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.
More informationAmeriplate. Rain Screen Wall System
Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the
More informationINSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines
ZIP System R12 Sheathing INSTALLATION MANUAL Contents 02 ZIP System R12 Sheathing General Notes, Guidelines and Limitations 03 ZIP System R12 Sheathing Installation 05 ZIP System R12 Sheathing Non Structural
More informationARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM
RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)
More informationARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM
RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)
More informationTechnical Data Sheet
Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.
More informationOmniplate Barrier Wall System
is an economical barrier wall system with visible caulk joints at all horizontal and vertical panel joints. As a barrier wall, serves as the primary weather barrier for the building envelope. It can be
More informationRESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80 Contents Introduction How to Use this Guide...1 Split-Insulation Wall Assembly...2
More informationSPECIFICATIONS MODERRA MORTARLESS MASONRY VENEER
SPECIFICATIONS MODERRA MORTARLESS MASONRY VENEER PART 1: GENERAL 1.01 Section Includes A. Product description and definitions. B. Constructing base ledge for concrete wall units. C. Installing modular
More information900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900
CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900
More information