ELEVATION FOR DETAIL REFERENCE ONLY

Size: px
Start display at page:

Download "ELEVATION FOR DETAIL REFERENCE ONLY"

Transcription

1 SOFFIT 19 OUTSIDE CORNER INSIDE CORNER OPENING 14 END WALL ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08 CSV-09 CSV-10 CSV-11 CSV-12 CSV-13 CSV-14 CSV-15 CSV-16 CSV-17 CSV-18 CSV-19 CSV-20 INDEX STANDARD PANEL OFFERING SIDE LAP DETAILS WALL SECTIONS WALL SECTIONS WALL SECTIONS BASE DETAILS BASE & PARAPET DETAILS STACK JOINT DETAIL HORIZONTAL REVEAL DETAILS HEAD OPENING DETAILS JAMB OPENING DETAILS - (HIGH CELL & LOW CELL) JAMB OPENING DETAIL - () SILL OPENING DETAILS HEAD, JAMB, SILL INTERSECTION (MICROLINE) HEAD, JAMB, SILL INTERSECTION () END WALL DETAILS - (HIGH CELL & LOW CELL) END WALL DETAILS - () SOFFIT DETAILS OUTSIDE CORNER DETAILS CSV-21 INSIDE CORNER DETAILS CSV-22 PENETRATION (1 of 2) CSV-23 PENETRATION (2 of 2) INDEX NOTE: DETAILS ARE FOR PROMOTIONAL USE ONLY. FOR COMPLETE DETAILS, REFER TO CENTRIA'S WEB SITE AT CSV-01

2 16" [406] EXTENDED FASTENER LEG 1.6 [41] 2.4 [61] CS-660E 7 8 " [22] CS-660 Panel Option For Use With Attachment Clips and Fixing point fastener 16" [406] EXTENDED FASTENER LEG 9.6 [244] CS-630E 7 8 " [22] CS-630 Panel Option For Use With Attachment Clips and Fixing point fastener 16" [406] EXTENDED FASTENER LEG 5.6 [142] 5.6 [142] CS-620E 7 8 " [22] CS-620 Panel Option For Use With Attachment Clips and Fixing point fastener 16" [406] EXTENDED FASTENER LEG 9.6 [244] CS-610E 7 8 " [22] CS-610 Panel Option For Use With Attachment Clips and Fixing point fastener 12" [305] EXTENDED FASTENER LEG 1.6 [41] 2.4 [61] CS-260E 7 8 " [22] CS-260 Panel Option For Use With Attachment Clips and Fixing point fastener 12" [305] EXTENDED FASTENER LEG 5.6 [142] CS-220E 7 8 " [22] CS-220 Panel Option For Use With Attachment Clips and Fixing point fastener 12" [305] EXTENDED FASTENER LEG 5.6 [142] CS-210E 7 8 " [22] CS-210 Panel Option For Use With Attachment Clips and Fixing point fastener 12" [305] EXTENDED FASTENER LEG 9.6 [244] CS-200E 7 8 " [22] CS-200 Panel Option For Use With Attachment Clips and Fixing point fastener CSV-02 Dec 12

3 CS-660E 16"[406] NOMINAL COVERAGE CS-630E 16"[406] NOMINAL COVERAGE CS-620E 16"[406] NOMINAL COVERAGE CS-610E 16"[406] NOMINAL COVERAGE CS-260E 12"[305] NOMINAL COVERAGE CS-220E 12"[305] NOMINAL COVERAGE CS-210E 12"[305] NOMINAL COVERAGE SIDE LAPS CS-200E 12"[305] NOMINAL COVERAGE CSV-03

4 DRAINED & VENTED CAVITY INTERIOR SHEATHING STUD CONCEPT SERIES PANEL WITH EXTENDED FASTENING LEG (NO CLIP REQUIRED) HORIZONTAL 3/4" [19] DEEP 16 GA. INSULATION PANELS ON PROTECTED WITH CAVITY INSULATION VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. = NOT BY CENTRIA DRAINED & VENTED CAVITY CONCEPT SERIES PANEL WITH EXTENDED FASTENING LEG (NO CLIP REQUIRED) HORIZONTAL 1/2" [13] DEEP 16 GA. HORIZONTAL GIRTS BARRIER (PROVIDED BY FACE PANEL) VERTICAL LINER PANEL WITH FACTORY APPLIED SEALANT AIR BARRIER (LINER PANEL) FIELD-APPLIED (1.65 PCF) INSULATION IN LINER CAVITY PANELS WITH INSULATION IN VERTICAL LINER = NOT BY CENTRIA CSV-04 Aug. 11

5 CONCEPT SERIES PANEL WITH EXTENDED LEG FASTENING (NO CLIP REQUIRED) METALWRAP INSULATED BACK-UP PANEL FASTEN PANEL THROUGH EXTENDED LEGS "A" "A" METALWRAP CONT. ZEE AT EACH PANEL SIDE JOINT (36" O.C.) METALWRAP INSULATED BACK-UP PANEL SECTION A-A CONCEPT SERIES PANEL 3 4 " DRAINED & VENTED CAVITY PANELS WITH METALWRAP INSULATED BACK-UP PANEL = NOT BY CENTRIA DRAINED & VENTED CAVITY CONCEPT SERIES PANEL WITH EXTENDED LEG FASTENING (NO CLIP REQUIRED) FASTEN PANEL THROUGH EXTENDED LEG INTO ZEES CON'T. HORIZONTAL ZEE 16 [1.52] GA. MIN. (SPACING TO BE DETERMINED BY CLADDING ENGINEER) INTERIOR SHEATHING STUD INSULATION SUITABLE FOR MOISTURE EXPOSURE PANELS WITH INSULATION OUTBOARD OF STUD CAVITY VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. = NOT BY CENTRIA CSV-05 Aug. 11

6 MASONRY FASTENER (*) CONTINUOUS HORIZONTAL ZEE SHAPED (SHIM AS REQUIRED) (*) S SHALL BE 1.) 16 GA. MINIMUM. 2.) 3/4" [19] MINIMUM DEPTH. 3.) SPACED AT 24" [610] OR 48"O.C. [1219] BASED ON DESIGN LOADS AND INSULATION SIZE. CONCEPT SERIES PANEL WITH EXTENDED FASTENING LEG (NO CLIP REQUIRED) MASONRY INSULATION SUITABLE FOR MOISTURE EXPOSURE AIR BARRIER & WATER RESISTANT COATING OR MEMBRANE DRAINED & VENTED CAVITY PANELS WITH INSULATION OVER MASONRY WALL VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. = NOT BY CENTRIA CONCEPT SERIES PANEL WITH EXTENDED FASTENING LEG (NO CLIP REQUIRED) HORIZONTAL GIRTS FINISH IS REQUIRED ON BOTH SIDES OF THE PANEL SINCE BOTH SIDES ARE EXPOSED TO THE WEATHER PANELS USED AS A SCREEN WALL = NOT BY CENTRIA CSV-06 Aug. 11

7 STUDS TAPE DESIGN OF BASE MUST VARY TO SUIT CONCRETE PLACEMENT AND FORMING TOLERANCES 5" [127] BASE DETAILS (CS-7503) 2" [51] 2" [51] SP-4222 SEALANT BASE DETAILS (CS-7503B) STUDS TAPE CENTER LINE OF SP-4144 SP-4142 SP-4141 SEALANT " 9 16 " [14] B\EXTRU [44] " [86] TOP OF RETAINER (SP-4141) = NOT BY CENTRIA CSV-07

8 PARAPET 5 SLOPE 2"[51] MIN. METAL CLOSURE STUDS PARAPET (CS-7010) STUDS TAPE T/CURB 1 8 "[3] GAP BASE DETAIL () (CS-7003) 1"[25] B/FLASH = NOT BY CENTRIA CSV-08

9 TAPE 1 8 "[3] CLR. STUDS METAL CLOSURE STACK JOINT (CS-7004) = NOT BY CENTRIA CSV-09

10 STUDS SP " [51] SP " [25] METAL CLOSURE SP HORIZONTAL REVEAL (CS-7504) SP-4173 STUDS 5" [127] SP-4173 METAL CLOSURE SP-4169 HORIZONTAL REVEAL (CS-7504A) = NOT BY CENTRIA CSV-10

11 BARRIER AND AIR STUDS TAPE SP-4143 METAL AND COMPOSITION CLOSURES HEAD OPENING () (CS-7500) 2" [51] CLEAR OPNG. SP-4142 DOOR, WINDOW OR LOUVER SHIM AS REQUIRED SP-4141 TAPE 1/8"[3] GAP WEATHER SEAL HEAD OPENING ( ) (CS-7000) STUDS CURING BUTYL EXTEND VPWB PRIMARY AIR SEAL DOOR, WINDOW OR LOUVER R.O. B/SUPPORT = NOT BY CENTRIA CSV-11

12 STUDS EXTERIOR SHEATHING 6"[152] MAXIMUM CANTILEVER CLEAR OPNG. PRIMARY AIR SEAL DOOR, WINDOW OR LOUVER SHIM AS REQUIRED SP-4143 TAPE SP " [51] JAMB OPENING (HIGH CELL) (CS-7502) STUDS 6"[152] MAXIMUM CANTILEVER CLEAR OPNG. PRIMARY AIR SEAL SHIM AS REQUIRED WEATHER SEAL TAPE SP-4143 JAMB OPENING (LOW CELL) (CS-7502A) 2" [51] DOOR, WINDOW OR LOUVER = NOT BY CENTRIA CSV-12

13 R.O. STUDS PRIMARY AIR SEAL CURING BUTYL DOOR, WINDOW OR LOUVER WEATHER SEAL 4" [102] JAMB OPENING () (CS-7002) JAMB DETAILS = NOT BY CENTRIA CSV-13

14 CLEAR OPNG. SP " [51] METAL CLOSURE SP-4141 TAPE STUDS SILL OPENING () (CS-7505) "[64] MIN. WINDOW OR LOUVER METAL CLOSURE SILL OPENING () (CS-7005) STUDS = NOT BY CENTRIA CSV-14

15 INTERSECTION OF HEAD, JAMB & SILL S (CS-7513) = NOT BY CENTRIA CSV-15

16 INTERSECTION OF HEAD, JAMB & SILL (CS-7013) = NOT BY CENTRIA CSV-16

17 TAPE 6"[152] MAXIMUM CANTILEVER STUDS SUPPORT FLASH SP-4141 SP-4144 END WALL (HIGH CELL) (CS-7506) 2" [51] TAPE 6"[152] MAXIMUM CANTILEVER STUDS SP-4144 END WALL DETAILS SUPPORT FLASH SP-4144 END WALL (LOW CELL) (CS-7506A) 2" [51] SP-4141 = NOT BY CENTRIA CSV-17

18 TAPE BARRIER AND AIR STUDS SUPPORT FLASH END WALL at HIGH CELL () (CS-7006) 4"[102] MIN. NON-CURING BUTYL POLYURETHANE TAPE BARRIER AND AIR STUDS SUPPORT FLASH END WALL at LOW CELL () (CS-7006) 4"[102] MIN. NON-CURING BUTYL POLYURETHANE = NOT BY CENTRIA CSV-18

19 BARRIER AND AIR STUDS TAPE SOFFIT - FRONT () (CS-7016) METAL AND COMPOSITION CLOSURES STUDS METAL AND COMPOSITION CLOSURES "MIN. [64] "MIN. [64] METAL CLOSURE BARRIER AND AIR SOFFIT - BACK () (CS-7017) = NOT BY CENTRIA CSV-19

20 DESIGN MAY VARY DUE TO PANEL MODULE LAYOUT STUDS SP-4172 SP-4171 SUPPORT FLASH 6"[152] MAX. CANTILEVER BARRIER AND AIR " [105] OUT SIDE CORNER () (CS-7507) STUDS SUPPORT FLASH "[114] MIN. OUT SIDE CORNER OUT SIDE CORNER ( ) (CS-7007) = NOT BY CENTRIA CSV-20

21 STUDS SP-4141 SP-4144 TAPE 6"[152] MAXIMUM CANTILEVER SUPPORT FLASH (CS-7509B) DESIGN MAY VARY DUE TO PANEL MODULE LAYOUT STUDS "[114] MIN. SUPPORT FLASH INSIDE CORNER (CS-7009) = NOT BY CENTRIA CSV-21

22 NOTE:- REF. PAGE CSV-23 FOR SECTS. A-A & B-B PENETRATION DETAIL (CS-7012) = NOT BY CENTRIA CSV-22 Aug. 11

23 TAPE 1 8 '[3] GAP ANGLE STUDS SECTION A-A (CS-7012A) TAPE TAPE PENETRATION DETAIL SECTION B-B (CS-7012B) POLYURETHANE SEALANT (TYPICAL ALL AROUND) EXTERIOR SHEATHING = NOT BY CENTRIA CSV-23

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS

More information

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL

More information

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

FACE CFP - HORIZONTAL PANELS - OPTION 'B' - Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY #smr_elev 5b SEC 2 8i SEC 2 33 SEC 4 1a SEC 2 37 SEC 4 36 SEC 4 35 SEC 4 SOFFIT FRONT 6d SEC 2 7a SEC 2 SOFFIT REAR INSIDE CORNER (REAR) OUTSIDE CORNER (FRONT) 10a SEC 2 9b SEC 2 4e SEC 2 ELEVATION FOR

More information

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM

More information

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition

More information

CENTRIA Concept Series Metal Wall Panels ZINC

CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles and five

More information

WeatherSmart Air Barrier Installation Guide

WeatherSmart Air Barrier Installation Guide WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material

More information

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.

More information

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer... SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) SECTION 07 42 13.01 METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 620 AAMA 621 Voluntary Specification for High Performance Organic Coatings

More information

How do you install yours?

How do you install yours? How do you install yours? Darrell Paul Qualistat Building Performance Consultants CSA 440 Just about adding Peel & Stick? 1 Window and door problems Photos / videos Video available for viewing at INSTAGRAM

More information

Magnum Board Coatings

Magnum Board Coatings Master Wall Mesh and Base Coat Plastic Control Joint Accessory, Plastic Components 22027-16 or equal. See notes for placement recommendations Notes: Control joints are required and should be located by

More information

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) SECTION 07 42 13.03 METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 620 AAMA 621 Voluntary Specification for High Performance Organic Coatings

More information

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing

More information

SC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish

SC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish Master Wall Mesh and Base Coat Plastic Control Joint Accessory, Plastic Components 22027-16 or equal. See notes for placement recommendations Notes: Control joints are required and should be located by

More information

Proper Installation of Insulated Metal Wall Panels

Proper Installation of Insulated Metal Wall Panels Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

KARRIER PANEL - BRICK

KARRIER PANEL - BRICK KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK

More information

Prestige Series 12. Installation guide

Prestige Series 12. Installation guide Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................

More information

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre is a unique modular metal wall system designed, available from a reliable national manufacturer and supported

More information

Schedule A Development Permit No Issued this 18 day of April, 2018

Schedule A Development Permit No Issued this 18 day of April, 2018 Schedule A Development Permit No. 001610 Issued this 18 day of April, 2018 N No. Revision/Issue Date MM/DD/YY 1 ISSUED FOR TENDER 10/26/17 LEGEND: WORK AREA VILLAGE STROLL VILLAGE GREEN SOUTH WING 1 0

More information

CENTRIA FORMABOND II Metal Composite Wall System

CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FormaBond II is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer

More information

ARCHITECTURAL DESIGN GUIDE

ARCHITECTURAL DESIGN GUIDE HPCI BARRIER TM INSULATED METAL PANEL ARCHITECTURAL DESIGN GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY TABLE OF CONTENTS INTRODUCTION...6 RAINSCREEN WALL

More information

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier Typical Details (THIS PAGE INTENTIONALLY LEFT BLANK Pebbletex Wall System Class PB Exterior Insulation

More information

CENTRIA FORMABOND. Aluminum Composite Wall System

CENTRIA FORMABOND. Aluminum Composite Wall System CENTRIA FORMABOND Aluminum Composite Wall System CENTRIA FormaBond is the only true aluminum composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer

More information

The better way to build TM. Installation Manual NAILBASE PANELS

The better way to build TM. Installation Manual NAILBASE PANELS The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

CENTRIA Concept Series TM Metal Wall Panels

CENTRIA Concept Series TM Metal Wall Panels CENTRIA Concept Series TM Metal Wall Panels CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles, metal substrates,

More information

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900 CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: HCI System RAINSCREEN ATTACHEMNT HORIZONTAL ORIENTED GIRT VERTICAL PanelRail & RevealRail SYSTEM DEPTH: 1.5 INCHES (FACE OF RIGID INSULATION TO FACE OF RAIL) QUICK LINK:

More information

Guide Specification for the OSI QUAD Window and Door Flashing System

Guide Specification for the OSI QUAD Window and Door Flashing System Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification

More information

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT SECTION 04110 MORTAR AND MASONRY GROUT PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. In the absence of other information, the methods and recommendations of the National Concrete Masonry Association

More information

NFPA 285 Assemblies. Table of Contents

NFPA 285 Assemblies. Table of Contents Effective 12/16/2014 Supersedes all previous versions NFPA 285 Assemblies The following Henry assemblies meet the performance requirements of NFPA 285 as required by the International Building Code (2003,

More information

NFPA 285 Assemblies. Table of Contents

NFPA 285 Assemblies. Table of Contents Effective 1/7/2014 Supersedes all previous versions NFPA 285 Assemblies The following Henry assemblies meet the performance requirements of NFPA 285 as required by the International Building Code (2003,

More information

CONTOUR CORRUGATED PANEL

CONTOUR CORRUGATED PANEL CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details

More information

Commercial Flashing Details

Commercial Flashing Details This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from

More information

200 / 300 SERIES PANELS COLD STORAGE

200 / 300 SERIES PANELS COLD STORAGE CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES

More information

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines ZIP System R12 Sheathing INSTALLATION MANUAL Contents 02 ZIP System R12 Sheathing General Notes, Guidelines and Limitations 03 ZIP System R12 Sheathing Installation 05 ZIP System R12 Sheathing Non Structural

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: HCI System (HORIZONTAL HCI-Girt ) for CLADDING PANELS HORIZONTAL ORIENTED GIRT ONLY SYSTEM DEPTH: 0.75 INCHES (FACE OF RIGID INSULATION TO FACE OF RAIL) QUICK LINK: SECTION

More information

WrapShield SA Brick Tie Penetration

WrapShield SA Brick Tie Penetration Brick Tie Penetration Outboard Vapor - Pemeable Insulation WrapShield SA Self-adhered WRB/AB field membrane Brick Tie must be Flush and compressed against Membrane with no prong penetrations Gasketed Fastener

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: MFI System - S-Series (VERTICAL) for CLADDING PANELS VERTICAL ORIENTED SYSTEM WITH OPTIONAL HORIZONTAL PanelRails (EXTERIOR INSULATION OMITTED FOR CLARITY) MINIMUM DEPTH:

More information

CENTRIA Exposed Fastener Series Metal Wall Panels

CENTRIA Exposed Fastener Series Metal Wall Panels CENTRIA Exposed Fastener Series Metal Wall Panels CENTRIA Exposed Fastener Series Metal Wall Panels are a versatile design choice for both new and retrofit projects. Exposed Fastener Metal Wall Panels

More information

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers version 2.5 updated as of 08.04.2017 2 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers 2.0 ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation

More information

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

BENCHMARK Evolution Axis

BENCHMARK Evolution Axis Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL

More information

Wall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3" = 1'-0"

Wall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3 = 1'-0 Thermafiber "RainBarrier 45" Nvelope "NH2" Bracket Adapter Nvelope Wall Bracket (90mm or as Req'd) ACM Metal Panel System Metal Panel Extrusion per ACM Manufactuer 1 2 " Self-Drilling Stainless Steel Fastener

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 061600 - SHEATHING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: MFI System - S-Series (HORIZONTAL) for CLADDING PANELS HORIZONTAL ORIENTED SYSTEM WITH OPTIONAL VERTICAL PanelRails (EXTERIOR INSULATION OMITTED FOR CLARITY) MINIMUM

More information

Ameriplate. Rain Screen Wall System

Ameriplate. Rain Screen Wall System Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the

More information

Henri Fennell, CSI/CDT ABX 2015

Henri Fennell, CSI/CDT ABX 2015 Henri Fennell, CSI/CDT ABX 2015 Henri is an architect and building envelope specialist with over forty years of experience in the construction industry. He was a pioneer in the solar industry, introduced

More information

WEIGHT PER PIECE (LBS.)

WEIGHT PER PIECE (LBS.) PRODUCT DESCRIPTION DATA SHEET 04 73 19-US BASIC USE ProGUARD DP is intended to be installed over sheathing and waterproofing over steel or wood studs or over concrete masonry units or poured concrete

More information

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details Typical Details AcroWall-ES System Class PB Exterior Insulation and Finish System providing a primary moisture barrier 1. Typical AcroWall-ES System Application 2. Typical Aesthetic Reveal 3. Typical Window

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

SECTION SELF-ADHERING SHEET FLASHING

SECTION SELF-ADHERING SHEET FLASHING MANUFACTURER S GUIDE SPECIFICATIONS SECTION 076526 SELF-ADHERING SHEET FLASHING 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 604129 03.24.15 Carlisle, Flexphalt, Sure-Seal and CAV-GRIP

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

Building Envelope Enclosures That Work, What Owners Want!

Building Envelope Enclosures That Work, What Owners Want! WEBINAR February 23, 2017 Building Envelope Enclosures That Work, What Owners Want! Will Ikerd, P.E. (TX), LEED AP Webinar Speakers Karl Strand President of Vertical Solutions Consulting Will Ikerd, PE

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights 1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.

More information

Insulated Metal Panel (IMP) Systems

Insulated Metal Panel (IMP) Systems METL-SPAN Joseph Lstiburek, Ph.D., P.Eng. November, 2015 Table of Contents 1. Physics of Building Enclosures... 4 2. Physics of Insulated Metal Panels... 12 3. Joint Design... 19 4. Thermal Bridging...

More information

7.0 - EXAMPLE DETAILS

7.0 - EXAMPLE DETAILS 7.0 - EXAMPLE DETAILS The drawings represented herein are believed to be accurate and conforming to current design and construction practices. However, the drawings should be used as a reference guide

More information

Building Enclosure Details and Assemblies for Wood-Frame Buildings

Building Enclosure Details and Assemblies for Wood-Frame Buildings Building Enclosure Details and Assemblies for Wood-Frame Buildings COLIN SHANE M.ENG., P.ENG. ASSOCIATE, SENIOR PROJECT MANAGER RDH BUILDING SCIENCES INC. NOVEMBER 19, 2015 Disclaimer: This presentation

More information

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an

More information

TruGrain 12 Inch Commercial Profile Installation Recommendations

TruGrain 12 Inch Commercial Profile Installation Recommendations TruGrain 12 Inch Commercial Profile Installation Recommendations o Delivery, Storage and Handling o General Requirements o Application of Stain & Sealer o Storage and Handling (Post-Treatment) o Installation

More information

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing INSTALLATION INSTRUCTION FOR SINGLE-HUNG AND FIXED WINDOW REPLACEMENT using FLUSH FLANGE Installation Instructions for replacing windows in a Typical Stucco Application. These instructions were developed

More information

application instructions

application instructions application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds

More information

GA APPLICATION OF GYPSUM SHEATHING

GA APPLICATION OF GYPSUM SHEATHING 1. Scope 1.1 This specification describes the minimum requirements for, and the methods of handling, storage, and application of, gypsum sheathing for use as a substrate for exterior claddings. 1.1.1 Exterior

More information

RESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide

RESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide RESIDENTIAL INSULATED SHEATHING TM COMFORTBOARD 80 Installation Guide Table of Contents Introduction How to Use this Guide...1 Split-Insulation Wall Assembly...2 Insulation... 3 Nominal and Effective R-Values

More information

CENTRIA MetalWrap Insulated-Composite Backup Panel System

CENTRIA MetalWrap Insulated-Composite Backup Panel System CENTRIA MetalWrap Insulated-Composite Backup Panel System CENTRIA MetalWrap Insulated Composite Backup Panel System is designed to be used with CENTRIA metal wall panel cladding to create a complete rainscreen

More information

Ultra Wall System. CAD Detail Sets

Ultra Wall System. CAD Detail Sets Ultra Wall System CAD Detail Sets Contents Page UWS-CM CAVITYMATE Ultra Contents 1-0 FOR: Details continuing on 1-1 thru 1-17 Cavity cut XPS board to fit between ladder tie masonry ties in CMU walls UWS-SL

More information

GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50

GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50 MASONRY ANCHOR DETAILING:. GASKETED STANDOFF ANCHOR 0 MIN.. SURFACE MOUNTED ANCHOR " MIN. 7 9. LADDER STYLE ANCHOR.. MASONRY ANCHOR DETAILING. S00, -INCH TROWELED BEAD. MORTAR COLLECTION MESH. PERM-A-BARRIER

More information

Cowhorn Residence. PHnw 2017 Cowhorn Residence

Cowhorn Residence. PHnw 2017 Cowhorn Residence Cowhorn Residence LEARNINGOBJECTIVES Course Approved for CPHC Continuing Education Credits 1. Learn how to orient buildings based on site conditions and owner criteria 2. Understand the impact of site

More information

Metafor Panel System Installation Guide

Metafor Panel System Installation Guide Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE

More information

DuPont RainVent Batten Installation Guidelines

DuPont RainVent Batten Installation Guidelines DuPont RainVent Batten Installation Guidelines Purpose: To improve the ventilation and draining space behind a cladding system or 3-coat stucco system in residential construction. The DuPont RainVent Batten

More information

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2 DuPont Tyvek Air Barrier Installation Guidelines Helping you get the job done right Canadian Version Version 2 Table of Contents Applicable Products...2 Required Materials...2 Code Requirements...3 General

More information

architectural design GuIde HPCI BarrIer Insulated metal Panel

architectural design GuIde HPCI BarrIer Insulated metal Panel architectural design GuIde HPCI BarrIer Insulated metal Panel table of contents INTRODUCTION...6 RAINSCREEN WALL BASICS...7 The Building Envelope...7 Basic Wall Types...7 RAINSCREEN WALL DESIGN...8 Rainscreen

More information

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C Stratum Guard I and II System Installation Details Stratum Guard I and II DETAIL Table of Contents NOTE SG.0.0.01 SG.0.0.02

More information

Contents. ZIP System R-Sheathing

Contents. ZIP System R-Sheathing ZIP System R-Sheathing 2 Contents 02 ZIP System R-Sheathing General Notes, Guidelines and Limitations 03 ZIP System R-Sheathing Installation 05 Structural Bracing to Resist Lateral Forces 06 ZIP System

More information

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity) September 2014 NU-WALL EXTRUDED ALUMINIUM CLADDING Installation Specifications Vertical orientation (over cavity) 1. NW-V001C; Cavity batten layout 2. NW-V002C; Battening options 3. NW-V002C; Battening

More information

Detail Drawings THE BEST PANEL COMPANY. from. 126 Old Highway 60 East Hardinsburg, Kentucky Office:

Detail Drawings THE BEST PANEL COMPANY. from. 126 Old Highway 60 East Hardinsburg, Kentucky Office: Detail Drawings from Rev. 4/2017 126 Old Highway 60 East Hardinsburg, Kentucky 40143 Office: 270-788-3535 www.bestpanelcompany.com Dri-Plane screen / similar / Similar Non-Corrosive Fastener designed to

More information

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements Product Information & Installation Manual 01 Important Notice to Buyers and Users of RoyOMartin wall system These instructions are not intended to cover every installation requirement, application, detail

More information

UNDERSTANDING DIFFICULT CRITICAL TRANSITIONS OF AVB SYSTEMS

UNDERSTANDING DIFFICULT CRITICAL TRANSITIONS OF AVB SYSTEMS UNDERSTANDING DIFFICULT CRITICAL TRANSITIONS OF AVB SYSTEMS COREY S ZUSSMAN AIA, NCARB, ALA, REWC, RWC, RRO, CDT, CQM, LEED AP BD+C PEPPER CONSTRUCTION Air Barrier Association of America (ABAA) is a Registered

More information

typical section 1:50 Important:

typical section 1:50 Important: 00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of

More information

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER PART 1 - GENERAL 1.01 SUMMARY SECTION 07 65 00 FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER A. Section includes through wall masonry flashing system components for installation over sheathing where spray

More information

Product and System Specifications DuPont Flashing Systems

Product and System Specifications DuPont Flashing Systems DuPont Building Innovations March 2007 4417 Lancaster Pike Chestnut Run Plaza 721 Wilmington, DE 19805 1-800-448-9835 www.construction.tyvek.com Product and System Specifications DuPont Flashing Systems

More information

OSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION

OSB.COMFORT INSTALLATION GUIDE *  1 RECOMMENDED USE PANEL COMPOSITION STYRO RAIL 07-0 Expanded Polystyrene Rigid Insulation combined to an Oriented Structural Board INSTALLATION GUIDE * 9 mm [8 ] The OSB.Comfort boards manufactured by Styro Rail are composed of type expanded

More information

Dow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green

Dow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green Silicone Air Barrier System of shade energy-efficient A more green Air and Moisture Protection for More Energy-Efficient Buildings Meeting regulatory requirements for energy efficiency is a significant

More information

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)

More information

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED RAINSCREEN SYSTEM RAINSCREEN (H&J) SYSTEM INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630)

More information

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings application instructions STRAND SUBSTRATE 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH General At the time of manufacture, siding meets or exceeds the performance standards

More information

Aqua Coast Engineering

Aqua Coast Engineering Aqua Coast Engineering Ltd. P.O. Box 1367 Station A Delta, B.C. V4M 3Y8 Tel: (604)948-0958 Fax: 604)948-0959 September 1, 2011 Matthew Cheng File#:11145 Matthew Cheng Architect Inc. Fax: 604-731-3908 Unit

More information

CommercialComplete Wall System

CommercialComplete Wall System FOAMULAR XPS Insulation, Joint SealR Foam Joint Tape, Eco Touch Flame Spread 25, Eco Touch Thermal Batt FIBERGLAS Insulation NFPA 285 Fire Tested Wall Assemblies Owens Corning s Commercial Complete Wall

More information

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers. OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers. Designed to save material by functioning as an exterior cladding in thicknesses ranging from 3/8

More information