HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics
|
|
- Camron Barber
- 6 years ago
- Views:
Transcription
1 HEKAPLAST PE-HD twin wall cable ducts and cable protection pipes for underground installation HEGLER HEKAPLAST III/ HEKAPLAST: Twin wall cable ducts or cable protection pipes to DIN 696, manufactured from environmentally friendly PE-HD, available in coils or straight lengths Application: l Power supply lines Communication cables Wiring systems in rail traffic All kinds of wire harnesses in industrial construction Suitable for installation at low temperatures thanks to PE-HD Corrugated and Twin Wall Pipes of Plastics
2 20 00 HEKAPLAST Cable Ducts: Protective Pipes for Municipal infrastructure Under crossings of city roads a sufficient number of cable conduits should be provided for the accommodation of control and supply lines for lighting systems, road lighting and traffic management systems. Highway construction In highway construction, the necessary cable conduits along motorways and federal highways should be budgeted in the planning phase already. Wire harness is required for: Traffic management systems Emergency telephones Local power supply Railway systems It is common practice to install wiring systems for rail traffic management parallel to the tracks. More recent technical standards suggest the use of cable conduits. The flexibility of corrugated conduits renders this type of pipe particularly suitable for this purpose as it can be easily diverted around the pole foundations for overhead lines. Communication systems The fast-paced world of media and communication will necessitate a multiple of fibre optics for a reliable supply of each household in the future. By the provision of additional ductwork for cables, cost-intensive construction work can be avoided. 2
3 Versatile and Universal Use A forward-looking provision of cable ducts (empty tubes) can help to avoid subsequent and cost-intensive dig-up work. In road construction, cable ducts have a wide range of application, going from street lighting to the control of traffic management systems. Railway systems make use of cable ducts both in areas of high track density and in open route. 3
4 HEKAPLAST Cable Ducts: Protective Pipes for HEKAPLAST-R HEKAPLAST-R is a flexible twin wall pipe. Its extremely high flexibility in longitudinal direction makes the pipe particularly well-suited for complicated cable routes like installations around foundations or other obstacles. The table on page 6 shows the minimum bending radii applicable to the different HEKAPLAST-R sizes. The handy pull-in aid All HEKAPLAST rolls are supplied with a pull wire which is intended for the insertion of a hauling rope but not for cables. Tensile strength of the pull wire: a) steel wire: F R = 0.35 kn b) plastic wire: F R = 0.52 kn Product description HEKAPLAST cable ducts or cable protection pipes are made from PE-HD in twin wall design in accordance with DIN 696 Thermoplastics pipes and fittings with profiled outer and smooth inner surfaces. HEKAPLAST pipes are available in two options: straight lengths: HEKAPLAST-S rolls: HEKAPLAST-R Ring Stiffness The ring stiffness of HEKAPLAST pipes, when determined in accordance with DIN EN ISO 9969 Thermoplastic Pipes Determination of Ring Stiffness, is as follows: DN 40 to 0: S 8.0 kn/m² DN 25 to 200: S 5.0 kn/m² Professional installation provided, the pipe s stability under traffic loads is guaranteed by this. If tested according to DIN 696, HEKAPLAST has the following ring stiffness: DN 40 to 200: S R kn/m² (Pipe Class 4) 4
5 Simple Handling, Economic and Permanent Use Pipe joints Pipes are connected by couplings with tightness of the joint being ensured by special profiled seals. The seal should be lubricated and fitted in the first or second completely shaped corrugation of a pipe. Prior to jointing it is recommended that the insertion depth be marked on the pipe to ensure the joint is fully made. Tightness The degree of tightness of pipes and pipe joints depends on the classification of the pipe system in accordance with DIN EN Components and Meaning of IP Codes Identification letters IP Identification figure Meaning for Protection of Equipment against penetration of solids Meaning for Protection of Persons against access to dangerous parts with st figure 0 (no protection) (no protection),0 mm diameter back of hands 2 2,5 mm diameter fingers 3 2,5 mm diameter tools 4,0 mm diameter wire 5 protected against dust wire 6 dust-proof wire against penetration of water with harmful effects in case of 2 nd figure 0 (no protection) vertical dripping 2 dripping (gradient 5 ) 3 spray water 4 splash water 5 jet water 6 strong jet water IP Rating 66, 67: The IP ratings 66 and 67 are only met by HEKAPLAST-S (uncoiled product) and couplings without locking cams where the seal has been properly placed. It is important that the corrugation of the pipe profile remains undamaged. The rating is guaranteed for installation in earth-moist ground. The use in regular natural or layer ground water is not permissible. IP rating 54 (sand-tight): Sand-tightness to IP rating 54 is met by both HEKAPLAST types (R and S, coiled and uncoiled product) with no seals required in the couplings. 7 temporary submersion 8* permanent submersion * Test conditions to DIN EN : 99 + A : 2000 as agreed upon 5
6 The Size Range Technical details Nominal size (DN) Outside diameter Inside diameter Smallest possible bending radius (cm) ,8 33 ±0, ,0 40 ±0, ,2 52 ±0, ,4 65 ±0, ,7 78 ±0, ,0 95 ±, ,3 07 ±, ,9 39 ±, ,6 73 ±2,0.0 6
7 Installation instructions For the laying of HEKAPLAST cable ducts, the installation instructions of the manufacturer have to be observed. Adequate bedding in a sand or gravel layer (soil group ) and proper compaction, D Pr 95 %, ensure that the pipe s stability meets the requirements for laying depths between 0.8 and 6.0 m and traffic loads SLW 60 to DIN 072. Installation and bedding shall be carried out in accordance with the relevant technical specifications which are: DIN EN 60, ZTVA- StB 97 Excavations in Traffic Areas of FGSV, Installation Guide A 535 of Kunststoffrohrverband and TELECOM Specifications ZTV-FLN and 2. Multi-layer installation Gaps between the pipes shall be carefully backfilled and compacted by hand. In areas where high traffic loads occur, the pipe trench shall be backfilled with a sand/ cement mixture. If the laying depth is extremely low or high, pipes shall be bedded in a supporting layer of concrete. Storage and transport Pipes should be stored in the original stillages until installed. It is important that they be stored on an even and smooth surface at all times. Outdoor storage should be minimised and limited to a maximum period of six months (black colour). Handling during transport should be exercised with the usual care: scrubbing rims, unsecured freight or uneven support to be avoided, no tipping or throwing from vehicles. 7
8 HEKAPLAST Accessory HEKAPLAST-S (straight lengths) Nominal size DN Item No. o. M. ) Item No. m. M. 2) Stillage contents Stillage dimensions length width height lengths (m) ) without socket; 2) with socket; standard colour: black; standard length: 6 m. Other lengths/colours on request HEKAPLAST-R (coiled product) Nominal size DN Item No Coil length (m) Coil diameter (m) Coil width (m) Standard colour: black. Other colours on request. Accessories Nominal size DN Coupling Item No. m. A. ) Item No. o. A. 2) Profiled seal Item No Plug Item No Bend 45 Item No Bend 90 Item No Spacer ) with locking cam 2) without locking cam two-, four-, six-, eight-strand, available in one- and double-sided design The information given in this brochure is the most up-to-date available and is intended to provide information on our products and their possible applications. It is not a guarantee of certain features or of their suitability for certain specific applications. Our guarantee applies to compliance with our specifications, within the scope of our General Terms and Conditions. The current edition supersedes any former versions. Subject to change. Corrugated and Twin Wall Pipes of Plastics HEGLER PLASTIK GMBH D-9774 Oerlenbach/Germany Phone Fax
SIROPLAST-K. Pipe system for civil engineering subsoil drainage inspection chambers and subsoil drainage pipes to DIN
HEGLER II/1 Pipe system for civil engineering subsoil drainage inspection chambers and subsoil drainage pipes to DIN 4262-1 : Pipe system consisting of inspection chambers and subsoil drainage pipes. Twin
More informationKabuflex Installation manual
Kabuflex Installation manual 7 6 5 4 3 1 0,5 1 1,5,5 3 3,5 4 4,5 5 www.istockphoto.de Last modified: April 011 DRAINAGE SYSTEMS ELECTRICAL SYSTEMS BUILDING TECHNOLOGY INDUSTRIAL PRODUCTS Table of contents
More informationTelecommunications Infrastructure
Telecommunications Infrastructure Table of Contents Contents 1. INTRODUCTION... 2 2. DUCTING CAPACITY... 3 3. SUB DUCT SIZING... 4 4. DUCTING AND SUB DUCTING CONSTRUCTION AND COLOUR... 5 5. BUILDING ENTRANCE:...
More informationh Installation Manual
h Installation Manual 1 General Information The installation of HOBAS GRP Pipes is subject to applicable standards and guidelines such as EN 1610 and ISO/ TS 10465-1. Correct installation always requires
More informationMulticell. Vikimatic MultiCell Conduit Systems MULTICELL
Multicell Vikimatic MultiCell Conduit Systems These guidelines should help you install MultiCell Conduit in the simplest way possible and should be read in their entirety before attempting to install the
More informationPlease check with your local inspection authority for any additional requirements before installation.
Specifications for Residential Underground Electric Service Installation This brochure addresses most typical residential underground service installations. Variances for the following specifications must
More informationPETREX -CNT. Pipe systems for petrol stations Technical details
PETREX - Pipe systems for petrol stations Technical details Contents 1.0 1.0 Contents 1.10 1.100 System description System description PETREX - 1.11 1.11.01 Product overview Piping, connections, fittings
More informationORDINANCE ON TECHNICAL REQUIREMENTS FOR CABLE DUCTS
Pursuant to Article 12, paragraph 1, item 1 and Article 24, paragraph 8 of the Electronic Communications Act (Official Gazette No. 73/08), the Council of the Croatian Post and Electronic Communications
More informationMulti-Gard PVC Assembly/ Field Cuts
Multi-Gard PVC Assembly/ Field Cuts Assembly 1. Distribute Multi-gard sections along the sides of the trench with male ends pointing towards starting vault entrance.. Remove protective cap and install
More informationSPECIAL SPECIFICATION 4425 Thermoplastic Pipe
2004 Specifications CSJ 0264-07-028 SPECIAL SPECIFICATION 4425 Thermoplastic Pipe 1. Description. Furnish and install thermoplastic pipe for constructing thermoplastic pipe culverts or thermoplastic storm
More informationInstallation Guide BLUE904 PEX MUNICIPAL WATER SERVICE TUBING. We Build Tough Products for Tough Environments
Installation Guide BLUE904 PEX MUNICIPAL WATER SERVICE TUBING W A T E R S E R V I C E T U B I N G We Build Tough Products for Tough Environments Blue904 Installation Guide 1 TABLE OF CONTENTS Introduction...................................2
More informationA reliable solution for ditching, underpassing and rainwater drainage
PIPES AND CHAMBERS CULVERT PIPES A reliable solution for ditching, underpassing and rainwater drainage Culvert pipes are used to convey drain pipe water or rainwater under the ground. The smallest (110
More information1993 SPECIFICATIONS CSJ SPECIAL SPECIFICATION ITEM 4110 CONCRETE ENCASED DUCT BANK
1993 SPECIFICATIONS CSJ 581-1-95 SPECIAL SPECIFICATION ITEM 4110 CONCRETE ENCASED DUCT BANK 1. DESCRIPTION. This Item shall govern for the furnishing and installation of all materials and equipment for
More informationCORRUGATED DRAINAGE PIPES FOR DRAINING UNDERGROUND AND SURFACE RUNOFF WATER 01 / 2017 CATALOGUE
TERRAIN DRAINAGE CORRUGATED DRAINAGE PIPES FOR DRAINING UNDERGROUND AND SURFACE RUNOFF WATER 01 / 2017 CATALOGUE 2 CERTIFICATES OF QUALITY 3 Description of the system All modern projects are carried out
More informationMerrimac Municipal Light Department. Commercial Developments Policy
Merrimac Municipal Light Department Commercial Developments Policy General: This document provides specific instructions for the provision of underground electrical facilities associated with the construction
More informationReinforced concrete slot channel
Applicable Bodies of Rules: DIN EN 1433»Drainage channels for vehicular and pedestrian areas«din 19580»Drainage channels for vehicular and pedestrian areas«the following laying instructions are general
More informationVikimatic MultiCell Conduit Systems
Conduit Systems These guidelines should help you install MultiCell Conduit in the simplest way possible and should be read in their entirety before attempting to install the system to have as smooth an
More information50.20 Drainage Structure Design
50.20 Drainage Structure Design All drainage structures, with the exception of bridges, culvert bridges and, in some cases, culverts, shall be designed for HS20-44 loading. Refer to Section 50.22 for design
More informationTS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS
TORONTO TRANSPORTATION January 2012 TS 804 CABLES TABLE OF CONTENTS 1. DRAWINGS TTD 804.001 TTD 804.002 TTD 804.003 TTD 804.005 TTD 804.006 TTD 804.007 TTD 804.010 TTD 804.015 TTD 804.020 TTD 804.025 TTD
More informationPOLYETHYLENE AND POLYPROPYLENE NEW GENERATION INTERHOL MANHOLES FUTURE. BS OHSAS 18001:2007 No. АТ-00569/0. macedonian quality
POLYETHYLENE AND POLYPROPYLENE NEW GENERATION INTERHOL MANHOLES FUTURE ISO 9001:2008 No. АТ-10310/0 ISO 14001:2004 No. АТ-01397/0 BS OHSAS 18001:2007 No. АТ-00569/0 macedonian quality 25 or FOR TECHNOLOGY
More informationSPECIAL SPECIFICATION 6664 Level (3) Communications System
2004 Specifications CSJ 1200-05-014 SPECIAL SPECIFICATION 6664 Level (3) Communications System 1. Description. A. This Item will govern the installation of all facilities belonging to Level (3) Communications,
More informationSPECIAL SPECIFICATION 6658 Time Warner Communications System
2004 Specifications CSJ 1200-05-014 1. Description. SPECIAL SPECIFICATION 6658 Time Warner Communications System A. This Item will govern the installation of all facilities belonging to Time Warner Cable
More informationSewage and rainwater. Experience the leading GIGAPIPE System! GIGAPIPE System. PP-System SN8 DN / ID 150 mm DN / ID 1000 mm
Sewage and rainwater Experience the leading GIGAPIPE System! GIGAPIPE System PP-System SN8 DN / ID 150 mm DN / ID 1000 mm DROSSBACH corrugated GIGAPIPE Systems Lighter, more solid and truly higher quality!
More informationSELF-100 with slotted top
Drainage with system Technical data sheet SELF-100 with slotted top SERVICE ANRIN provides custom solutions and possibilities for the contract business. Here you benefit from reliable cooperation with
More informationAccess Chambers Systems
2011 Access Chambers Systems S y s t e m s Pioneers in PE Pipe Technologies Index QuadBox Access Chamber p.4 QuadBox Fittings p.6 RadBox Access Chamber p.8 RadBox Fittings p.10 Specialist Chambers p.11
More informationCONSTRUCTION SPECIFICATION FOR GROUNDING
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 609 NOVEMBER 2001 CONSTRUCTION SPECIFICATION FOR GROUNDING TABLE OF CONTENTS 609.01 SCOPE 609.02 REFERENCES 609.03 DEFINITIONS - Not Used 609.04 DESIGN
More informationEUROFLO TECHNICAL BROCHURE 1550MM 2150MM
EUROFLO TECHNICAL BROCHURE 1550MM 2150MM CONTENTS PAGE General 2 Material 4 Profiled pipes 5 Programme 6 Static property 8 Structure 9 Marking 10 Jointing system 11 Laying 12 System advantages at a glance
More informationDrainage for road construction and civil engineering works. Agrosil Drainagesystem. and shaftsystems PE-HD - DIN
Drainage for road construction and civil engineering works Agrosil 2500 Drainagesystem and shaftsystems PE-HD - DIN 4262-1 www.wps-gmbh.com WPS drainage system AGROSIL 2500 Leading pipe technology for
More informationA. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.
ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 05 28 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationEI INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV
Network(s): Summary: ENGINEERING INSTRUCTION EI 02-0019 INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV EPN, LPN, SPN This engineering instruction details the minimum requirements acceptable for the installation
More informationSection 2: Underground
Section 2: Underground GENERAL INSTALLATION REQUIREMENTS FOR UNDERGROUND FACILITIES Underground electric service and meter location will be established by NHEC upon site visit. In some instances the type,
More informationTS 803 DUCTS DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE
TORONTO TRANSPORTATION March 2012 TS 803 DUCTS TABLE OF CONTENTS 1. DRAWINGS TTD 803.001 TTD 803.010 DUCT INSTALLATION, PROTECTION AND MARKING WITHIN A TRENCH OPEN TRENCH DUCT INSTALLATION PROFILE 2. CONSTRUCTION
More informationCONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2004 CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used
More informationCITY OF UNION, OREGON TECHNICAL SPECIFICATIONS SECTION 9 UNDERGROUND UTILITIES
A. GENERAL 1. Scope. These specifications cover the installation of the utility systems and appurtenances for the electrical power, telephone, gas, and television as shown in the Drawings. The Work includes,
More informationSUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018
STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018 PART 1 - GENERAL... 2 1.1 Work Included... 2 1.2 Related Sections... 2 1.3 Reference Standards... 2 1.4 Shop Drawings... 3 1.5 Certificates...
More informationCONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 616 APRIL 2018 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03 DEFINITIONS
More informationSECTION UNDERGROUND ELECTRICAL CONSTRUCTION
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 41 UNDERGROUND ELECTRICAL CONSTRUCTION A. This section specifies the furnishing, installation, and connection of precast manholes and pullboxes with ducts
More informationSPECIAL SPECIFICATION 4653 Polypropylene Pipe
2004 Specifications CSJ 2158-01-013, Etc. SPECIAL SPECIFICATION 4653 Polypropylene Pipe 1. Description. Furnish and install polypropylene pipe for constructing polypropylene pipe culverts or polypropylene
More informationSELF-150. Technical data sheet
Drainage with system SELF-150 SERVICE ANRIN provides custom solutions and possibilities for the contract business. Here you benefit from reliable cooperation with our technical office staff and good contact
More informationCORRUGATED HDPE PIPES FOR SEWER AND STORMWATER
50 corrugated pipes CORRUGATED HDPE PIPES FOR SEWER AND STORMWATER TECHNICAL SPECIFICATIONS SANS 21138-3 ISO 9001/2008 The pipe is black outside and blue on the inside Supplied in lengths of 6 meters.
More informationHDPE HDPE. Factory PRESSURE PIPING SYSTEM DRAINAGE & SEWERAGE PIPING CABLE DUCT & SUB DUCT. Since 2002 HDPE. for Sewerage Storm Water System HDPE
PRESSURE PIPING SYSTEM DRAINAGE & SEWERAGE PIPING CABLE DUCT & SUB DUCT for Sea Water Intake for Gas Transportation for Sewerage Storm Water System Manholes Factory Since 2002 for Cold Water Supply & Irrigation
More informationIndependent certification of your products & services. 2.2 Relevant Standards 1. SCOPE
1. SCOPE This schedule specifies requirements for the AquaSpira CSR (Composite Steel Reinforced) pipe system as manufactured by AquaSpira Limited. It is applicable for underground gravity drains, sewer
More informationHeavy duty channels SF-300
Drainage with system Technical data sheet Heavy duty channels SF-300 SERVICE ANRIN provides custom solutions and possibilities for the contract business. Here you benefit from reliable cooperation with
More informationPolysewer Gravity Sewer System SPECIFICATION
Polysewer Gravity Sewer System SPECIFICATION July 2014 SCOPE OF WORKS To meet the specific performance criteria detailed within this specification and accompanying drawings. The completed drainage systems
More informationHDPE HDPE. Factory PRESSURE PIPING SYSTEM DRAINAGE & SEWERAGE PIPING CABLE DUCT & SUB DUCT. Since 2002 HDPE. for Sewerage Storm Water System HDPE
PRESSURE PIPING SYSTEM DRAINAGE & SEWERAGE PIPING CABLE DUCT & SUB DUCT for Sea Water Intake for Gas Transportation for Sewerage Storm Water System Manholes Factory Since 2002 for Cold Water Supply & Irrigation
More informationSECTION UTILITY POLYETHYLENE CONTAINMENT PIPE SYSTEMS
SECTION 02670 UTILITY POLYETHYLENE CONTAINMENT PIPE SYSTEMS PART 1 - GENERAL 1.01 WORK INCLUDED A. Trenching and other excavation. B. Ground water control. C. Pipe bedding. D. Installation of containment
More informationWOOD POLE SPAN WIRE SIGNAL SYSTEMS
7 A wood pole span wire traffic control signal system differs from a mast arm steel pole traffic control signal system in that it uses wood poles and span wires to place the signal indications in the driver
More informationASSEMBLY AND OPERATING MANUAL LTW SLIDE RAIL SYSTEM - Type FP
Manufacturer: LTW Tiefbauvertriebs GmbH Holter Weg 11 D 41836 Hückelhoven-Brachelen Phone: +49 (0) 24 62 / 2009 0 Fax: +49 (0) 24 62 / 2009 15 e-mail: info@ltw-verbau.de homepage: http:\ \ www.ltw-shoring.com
More informationSECTION ELECTRICAL UTILITY SERVICES
SECTION 33 71 73 ELECTRICAL UTILITY SERVICES PART 1 GENERAL 1.1 REFERENCES A. American Association of State Highway Officials (AASHO): 1. Standard Specifications B. California Administrative Code (CAC):
More informationCOD. (Corrugated Optic Duct)
OptiRoad in partnership with the SCANDENT Group are introducing into Australia and New Zealand an innovative and new patented conduit system called the COD (Corrugated Optic Duct) Overview Main Products
More informationSPECIAL SPECIFICATION 6666 Charter Communications System
2004 Specifications CSJ 1200-05-014 SPECIAL SPECIFICATION 6666 Charter Communications System 1. Description. A. This Item will govern the installation of all facilities belonging to Charter Communications,
More informationCONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 623 JANUARY 1990 CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT 623.01 SCOPE 623.02 REFERENCES 623.05 MATERIALS TABLE OF CONTENTS 623.05.01
More informationSpecifications for Residential Underground Electric Service Installation
Specifications for Residential Underground Electric Service Installation This brochure addresses most typical residential underground service installations. Variances for the following specifications must
More information3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).
SECTION 16111 CONDUITS PART 1 - GENERAL 1.01 DESCRIPTION A. General: Provide conduits, complete, as shown, specified or required per Contract Documents. Principal items include: 1. Rigid aluminum conduit.
More informationHDPE corrugated double wall pipes
HDPE corrugated double wall pipes Kabuplast - corrugated double wall HDPE pipes (high density polyethylene ) also known as «corrugated pipes»,»cable protection pipes» - produced according to Euro standard
More informationASSEMBLY AND OPERATING MANUAL LTW SLIDE RAIL SYSTEM - Type PV
Manufacturer: LTW Tiefbauvertriebs GmbH Holter Weg 11 D 41836 Hückelhoven-Brachelen Phone: +49 (0) 24 62 / 2009 0 Fax: +49 (0) 24 62 / 2009 15 e-mail: info@ltw-verbau.de homepage: http:\ \ www.ltw-shoring.com
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 604 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used
More informationTYPICAL INSTALLATION INSTRUCTIONS
TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect
More informationHeavy duty channels SF-150
Drainage with system Technical data sheet Heavy duty channels SF-150 SERVICE ANRIN provides custom solutions and possibilities for the contract business. Here you benefit from reliable cooperation with
More informationCable Protection Systems
Cable Protection Systems Installation Guide V.1 2018 GR-WI-602 Page 1 Introduction This guide addresses the acceptable methods and details for the installation of ducting & troughing systems. The purpose
More informationCONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 616 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT TABLE OF CONTENTS 616.01 SCOPE 616.02 REFERENCES 616.03
More informationAlthon slot channels Althon
Effectively innovative. Althon slot channels - the solid drainage system! Althon slot channels Althon Drainage systems Althon slot channels high resilience high performance! The Althon slot channel is
More informationAn introduction to. pipe jacking
An introduction to pipe jacking The pipe jacking technique The major applications for pipe jacking and microtunneling include new sewerage and drainage construction, sewer replacement and lining, gas and
More informationSECTION STORM SEWER PIPE
SECTION 4200 - STORM SEWER PIPE 4200.1 SCOPE: This section covers the requirements for all labor, equipment and materials for the installation of storm sewers pipes. Trenching guidelines are provided in
More informationWESTERN UNDERGROUND COMMITTEE GUIDE 3.4 (3.4/00/0565)
WESTERN UNDERGROUND COMMITTEE GUIDE 3.4 (3.4/00/0565) PLASTIC CONDUIT AND FITTINGS PLACING INSTRUCTION NOTE: This "Guide" summarizes the opinions, recommendations, and practices of the Western Underground
More informationversion GEODRAIN Double structured wall HDPE conduits for water drainage Cable Protection Drainage & Sewage
version 01.2015 GEODRAIN Double structured wall HDPE conduits for water drainage Cable Protection Drainage & Sewage 2 Safe runoff 05 WATER DRAINAGE WHAT EXACTLY IT IS; 07 HOW IT WORKS 09 GEODRAIN DRAINAGE
More informationAccording German Standard DIN part 1. Standard range of PVC-P based flexible waterstops for movement (expansion) and construction joint sealing
Product Data Sheet Edition 08/08/2014 Identification no: 02 07 03 50 330 0 000001 Sika Waterbar PVC-P Sika Waterbar PVC-P According German Standard DIN 18541 part 1 Standard range of PVC-P based flexible
More informationQuality Control. Field Bending. Allowable Offset for Super Duct
DESCRIPTION, ADVANTAGES Super Duct is recognized by major utilities, contractors and engineering firms as the premier ducting product available on the market. Super Duct is manufactured with a specialized
More informationCONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 604 NOVEMBER 2008 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used
More informationAPPLICATION FOR PIPE OR WIRE OCCUPANCY
APPLICATION FOR PIPE OR WIRE OCCUPANCY Please answer all questions and direct cover letter / project description, completed application, application fee, and three (3) copies of project plans to: AECOM
More informationSPC recently concluded a partnership with a leading Italian company providing innovative and complete polyethylene pipe systems in 30 countries.
50 corrugated pipes SPC celebrates 50 years of manufacturing concrete pipes and related products for the Southern African market. To further serve the region, SPC is proud to announce the manufacturing
More informationTHE ADVANTAGES HDPE MANHOLES
NIC HDPE manholes are custom fabricated for many varied applications including municipal and industrial manholes, sewer and storm water manholes, leach ate collection, sewer lift stations, siphon structures,
More informationSaudi Vitrified Clay Pipe Co.
Saudi Vitrified Clay Pipe Co. Practical tips for laying V.C.Pipes professionally Table of contents: 1. Unloading of the truck 2. Storage on site 3. Transportation to the pipe trench 4. Installation 5.
More informationSpecifications for Electrical Underground Residential Distribution Systems
Specifications for Electrical Underground Residential Distribution Systems Specification DDS-2 Revision 13, February 2010 ONCOR ELECTRIC DELIVERY COMPANY SPECIFICATIONS FOR ELECTRICAL UNDERGROUND RESIDENTIAL
More informationFlue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit)
Flue gas kit DN60 rigid in the duct 100193 Flue gas kit No Outlet set plastic 1 x Set 100193 39.10 (Quantities in the image differ from the set) 1003253 1001938 Spacer set * ( pieces) Top inspection opening
More informationRequirements for Measuring and Pricing of Traffic Signs and Road Markings
Requirements for Measuring and Pricing of Traffic Signs and Road Markings February 2017 TRANSPORT INFRASTRUCTURE IRELAND (TII) PUBLICATIONS About TII Transport Infrastructure Ireland (TII) is responsible
More informationSPECIFICATION FOR PIPE CULVERT CONSTRUCTION
SPECIFICATION FOR PIPE CULVERT CONSTRUCTION 1. SCOPE Pipe culverts shall be constructed in accordance with this specification and in conformity with the lines, levels and cross-sections shown on the drawings.
More informationSEWER & DRAIN SYSTEMS 1 SEWER & DRAIN SYSTEMS CATALOGUE
SEWER & DRAIN SYSTEMS 1 SEWER & DRAIN SYSTEMS CATALOGUE WWW.SIZABANTUPIPINGSYSTEMS.COM SEWER & DRAIN SYSTEMS 2 Table of Contents Table of Contents Foamcore 2 The Product 2 PVC-U a material of choice 2
More informationTUNNEL LINER PLATE INTRODUCTION GENERAL APPLICATIONS CHAPTER 11
CHAPTER 11 INTRODUCTION The open-trench method of placing underground conduits is commonly used on new construction of culverts, sewers and underpasses. Interference with traffic, as well as inconvenience
More informationCourse name : Outside Plant - Fibre Optics Civil Works Professional Knowledge and Skills for Certification
Course name : Outside Plant - Fibre Optics Civil Works Professional Knowledge and Skills for Certification Course Detail: DURATION: 5 days TARGET GROUP: Any person who needs to do trenching, duct installation,
More informationCW 3620 INSTALLATION OF UNDERGROUND TRAFFIC SIGNAL SERVICES TABLE OF CONTENTS
December 2012 CW 3620 INSTALLATION OF UNDERGROUND TRAFFIC SIGNAL SERVICES TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Constructions Specifications...
More informationSSAB water mains. A reliable and economically advantageous solution for water supply.
SSAB water mains A reliable and economically advantageous solution for water supply www.ssab.com/infra SSAB S SYSTEM OF WATER MAINS DISTRIBUTES CLEAN WATER SAFELY A system made up of steel water mains
More informationInnovative products for road construction and landscaping. landscaping. For cost-effective securing and maintenance of road verges.
Innovative products for road construction and landscaping landscaping For cost-effective securing and maintenance of road verges. Road-side safety Vorteile auf einen Blick RoadEdgePave is easy and cost-effective
More informationInstallation Overview
Installation Overview Access Cover & Frame See page 6 for detail Cover Supports Hardwood, Concrete or Galvanised Angle 225mm PVC Push On Cap Code: 750191 Shroud Code: 750138 225mm PVC Extension Pipe Cut
More informationTechnical Documentation
Technical Documentation Underground Container F-Line 1.500L, 3.000L, 5.000L, 7.500L, 10.000L 1. Location 1.1. Position to buildings The excavation space must not be within the minimum distance to buildings,
More informationSlotted top channels Z-100
Drainage with system Technical data sheet Slotted top channels Z-100 SERVICE ANRIN provides custom solutions and possibilities for the contract business. Here you benefit from reliable cooperation with
More informationDrainage System SOLID BLOCK 200
Drainage with system Technical data sheet Drainage System SOLID BLOCK 200 SERVICE ANRIN provides custom solutions and possibilities for the contract business. Here you benefit from reliable cooperation
More informationInstallation instructions and maintenance for the GRAF Optimax external commercial filter
Installation instructions and maintenance for the GRAF Optimax external commercial filter Optimax external commercial filter for green areas (pedestrian weight resistant)) Order- No. 340035 Optimax external
More informationCable Protection Systems
Cable Protection Systems Installation Guide V.1 2018 GR-WI-601 Page 1 Introduction This guide addresses the acceptable methods and details for the installation of CABLEprotect ducting & troughing systems.
More informationApplying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity & Crossing Permit. Design and Construction Guidelines
Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity & Crossing Permit Design and Construction Guidelines A Guide to Applying for a Kinder Morgan Cochin Canada / UTOPIA Canada Proximity
More informationBox sealing system DS 90
Sealing systems in fire-protection walls Box sealing system DS 90 The box sealing system DS 90 for cables, cable bundles and conduits. The fire-proof and smoke-proof box sealing is quick and easy to install
More informationSECTION A1 EXCAVATION AND BACKFILL GENERAL
SECTION A1 EXCAVATION AND BACKFILL GENERAL The work under this section shall include all excavation to such width and depth as shown on the drawings, specified herein, or ordered by the Engineer. Such
More informationFLEXWELL FHK. Flexible district heating pipe
FLEXWELL FHK Flexible district heating pipe The intelligent alternative: safe and economical through simplified planning and minimal civil construction costs Safety furnished by the corrugated steel casing
More informationTABLE OF CONTENTS
DIVISION 33: SEWER AND SEPTIC SYSTEMS 33 3633 UTILITY SEPTIC TANK DRAINAGE FIELD TABLE OF CONTENTS 33 0000-1 SECTION 33 3633-- UTILITY SEPTIC TANK DRAINAGE FIELD PART 1 - GENERAL 1.1 SUMMARY A. Includes
More informationDROSSBACH HD Series Corrugated Plastic Pipe Machines.
DROSSBACH HD Series Corrugated Plastic Pipe Machines. Drossbach HD series Fast, efficient and more flexible corrugated plastic pipe production. DROSSBACH has been producing corrugated plastic pipe machines
More informationWalls generally range from 600 to 1500 mm thickness, in wide between 2000 and 3500 mm and can be excavated to depths of 60m or more.
TECHNOLOGY Diaphragm walls Diaphragm walls are one of the most important technologies of special foundation engineering. A diaphragm wall is constructed using a trench excavated in ground and supported
More informationGLENWOOD PLACE 2 MAR 2015
PART 1 - GENERAL 1.01 SUMMARY: SECTION 16110 RACEWAYS A. Description: 1. Provide continuous conduit systems - beginning at the service point, to all distribution equipment and to every outlet and piece
More informationUnderground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11
Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (URD) Index General Discussion... 1-2 Description... 3-7 Drawings (Available
More informationTEMPORARY FACILITIES
MUNICIPAL LIGHT & POWER & CHUGACH ELECTRIC ASSOCIATION ELECTRIC SERVICE REQUIREMENTS EXCERPT TEMPORARY FACILITIES 2015 EDITION Effective August 3, 2015 This is an EXCERPT; the complete book is available
More informationNEMO TANK INSTALLATION GUIDE INSTALLATION INSTRUCTIONS FOR THE NEMO TANK STAGE
NEMO TANK INSTALLATION GUIDE INSTALLATION INSTRUCTIONS FOR THE NEMO TANK STAGE 1. Before undertaking the work 2. Receiving the materials 3. Handling and storage 4. Tank layout 5. Installing the tanks STAGE
More information