1 METAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS Building contractors are always looking for installation methods that will provide them with savings on labor and materials expenses. Here are some important answers to frequently asked questions. 1. Should I install a metal roof directly overtop of an asphalt shingle roof? No. Why? Premature Failure: Metal has a high degree of thermal expansion and contraction. As the roof heats up and cools down, it moves along both its length and its width. Placed directly against the granules on asphalt shingle, this movement will scratch the underneath of the panel and eventually expose the bare steel, thus potentially causing premature failure i.e. corrosion. Voided Warranty: The installation of a metal panel directly over top of an abrasive material voids the manufacturer s corrosion warranty (this would apply to Galvalume panel only as galvanized steel does not carry a corrosion warranty). Shape: The panel will take the shape of the underlying uneven surface and, in many cases, make shape issues visible that were previously hidden. 2. What if I lay down an underlayment before putting the metal roof on? This is certainly a better option, but you will still have the same concerns with regard to Shape (see above) and, should the underlayment wear away or tear and expose the metal to the asphalt shingle, there exists the potential for Premature Failure which would result in a Voided Warranty. If it is decided that this is going to be the installation method, recommended underlayments would be Grace Tri-Flex 30 and IKO Rooftop Guard. They are impervious to moisture and highly tear resistant. MMR does NOT recommend the use of 15# or 30# roofing felt (tar paper) for this application.
2 3. Does that mean I should be stripping all asphalt shingle roofs before laying metal down? No. MMR recommends the stripping of the existing asphalt shingles, however we understand that time and budget constraints do not always cooperate. Here is the recommended best practice for re-roofing over an asphalt shingle roof: Roof Deck: Inspect the existing shingle roof to determine if it is suitable as a barrier against condensation. Remember that a metal roof will, to a certain degree, develop condensation on the underside of the panels. Those areas that show signs of previous water infiltration (underlying sheathing is soft or spongy) or damage (missing or deteriorated shingles) should be repaired accordingly and rendered watertight with the use of ice & water shield and an appropriate sealant (if necessary). Ridges & Hips: Remove the cap shingles to avoid having a hump. If leaving exposed with the threat of rain / snow, cover with tarp or roof underlayment. Roof Edges: Cut the overhanging asphalt shingles flush with the fascia / rake boards. This will also remove the existing drip edge. This allows you to install your eave / rake trim true to the house with a clean, tight fit to the fascia boards. Firring (strapping): i. Hips, Ridge & All Protrusions: 9-12 inches of width on all sides of using plywood, OSB or similar decking (thickness to match other lumber). ii. Valleys: inches of width on either side using plywood, OSB or similar decking (thickness to match other lumber). iii. Gable & Eave Edges: 1 X 3 spruce firring or similar dimension light gauge steel framing, set back from edge by ¼ ½ so that it doesn t kick the trim out. iv. Interior of Roof Deck: 1 X 3 spruce firring or similar dimension light gauge steel framing, installed horizontally approximately 16 OC (use every 2 nd course of shingles are your guide).
3 4. All of this sounds like a lot of work. Why don t I just strip the roof? That is a valid comment and many contractors / homeowners decide to do just that. Here are considerations for both options: Leave Existing Roof In Place Pro: No need to pay for dump fees. Pro: No need to pay for new roof underlayment so long as existing roof is suitable as a barrier against condensation. Pro: If using firring, creates an air barrier between the metal panel and the roof. This allows condensation that develops on the underside of the panel to dry more quickly. Pro: If using firring, reduces thermal transfer to the underlying roof deck as the metal panel is sitting up off the asphalt shingles. Pro: If using firring, allows for a cost effective leveling of the roof surface if required. Pro: Reduces the burden placed on landfills each year. Con: Does not allow a thorough inspection of the roof deck prior to installing new roof. Con: Renders the installation of snow guards more difficult and potentially less secure. Neutral: Not accepted by all Strip Existing Roof Pro: Allows you to inspect the condition of the roof deck and make repairs as needed. Pro: Provides for a smooth, flat roof surface on which to install. Pro: Allows for the proper and thorough installation of an ice & water shield. Pro: Allows a solid and uniform surface into which snow guards can be fastened if required. Pro: Provides a solid surface for all fasteners. Con: Added costs through dump & disposal fees. Con: Added costs through new roof underlayment.
4 building codes (hurricane prone areas require installation to solid deck using specific UL-90 rated clips). 1. Do you have any pictures that clearly show the strapping of a roof? Absolutely. (Please refer to the following pages)
5
6
Pacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com Page2 INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationClassic and NB Tile Counter Batten and Batten
Classic and NB Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationALLMET CONTINENTAL INSTALLATION GUIDE
ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental
More informationINSTALLATION GUIDE.
INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Canyon Shake counter batten
More informationBARREL VAULT Tile Counter Batten and Batten Installation Guide
BARREL VAULT Tile Counter Batten and Batten Installation Guide www.boral.com Page2 BARREL VAULT Tile Actual Size= 43 13/16 x 15 5/8 Exposure= 43 1/4 x 14 Weight= 5.4lbs. per panel Panels per square (100
More informationSLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]
[Change these specifications as needed. Use this sample proposal at your own risk. This is a simple, general proposal and is not meant to be a comprehensive proposal for all situations or projects. If
More informationSSL-175. Specifications
SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES
More informationMAGNUM. I N S P E C T I O N S Inc. ROOF Walked on roof, crawled attic where accessible.
NAME: DATE: October 6, 2006 METHOD OF INSPECTION: ROOF Walked on roof, crawled attic where accessible. ADDRESS: MAIN ROOF COVERING SECONDARY ROOF COVERING Cement Tile: Strip Shingle: XX Tar and Gravel:
More informationDL-200. Specifications
DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01
More informationSECTION METAL ROOF AND SOFFIT PANELS
Metal Panel Systems, Inc. 11506 Reading Road Cincinnati, Ohio 45241-2512 Telephone: 800-554-6126 or 513-554-6120 Fax: 513-554-6121 www.metalpanelsystems.com info@metalpanelsystems.com Specifications for
More informationBrava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:
Brava Spanish Tile Installation Manual Brava Roof Tile Phone: 319-338-5706 Fax: 319-343-1038 www.bravarooftile.com This document includes the recommended and suggested installation procedures for Brava
More informationInstallation Guide. Mission Tile. Distributed by: BEST MATERIALS LLC, Phoenx AZ
RPM ROOFING Installation Guide Mission Tile Distributed by: BEST MATERIALS LLC, Phoenx AZ 602-272-8128 800-474-7570 www.bestmaterials.com Table of Contents OVERVIEW...1 CAUTION...1 DISCLAIMER...1 PRODUCT
More informationMinimizing Water Intrusion Through Roof Vents in High-Wind Regions
Minimizing Water Intrusion Through Roof Vents in High-Wind Regions http://www.fema.gov HURRICANE IKE RECOVERY ADVISORY Purpose: To recommend practices for minimizing water intrusion through roof vent systems
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION SECTION 07320 TWO-PIECE TAPERED MISSION CLAY ROOFING TILE PART 1 GENERAL 1.01 SECTION INCLUDES A. Formed clay roofing tiles, complete with components and other required accessories
More informationEVERSEAM 20 APPLICATION GUIDE
EVERSEAM 20 APPLICATION GUIDE Panel Overview Our Name Says It All!"#$%#&'()*+,!"#$%#&'(-.( Applications: The EverSeam panel is an architectural panel that is ideal for residential and light commercial
More informationENERGY STAR PARTNER. PBR & R Panel
ENERGY STAR PARTNER 1 Table of Contents Important Information Installation Information Technical Information Trims and Flashings Illustration Roo ng Installation Details Eave Flashing (EF-3) Eave Flashing
More informationBattenless. Installation Guide BATTENLESS INSTALLATION GUIDE 1
Battenless Installation Guide BATTENLESS INSTALLATION GUIDE 1 This manual provides general guidelines and procedures relating to the estimating and installation of Varitile roof products. It is not a training
More informationWestern States 7/8 Corrugated
Western States 7/8 Corrugated Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer / Installers..1 Fastener Placement and Selection.2-3 Key
More informationSlate. Material description
Slate Material description Roofing slate is a dense, durable, naturally occurring material that is essentially nonabsorbent. Two properties of slate are cleavage and fracture. It has natural cleavage,
More informationClassic Rib Roofing Panels DETAIL MANUAL
Metal Roofing Wholesalers Classic Rib Roofing Panels DETAIL MANUAL www.metalroofingwholesalers.com 1170 Topside Rd Louisville, TN 37777 The Classic Rib Roofing Panel Figure 1 House With Classic Rib Metal
More information2120 SW Poma Drive; Palm City, Florida Phone Fax
2120 SW Poma Drive; Palm City, Florida 34990 772-223-4055 Phone 772-781-7492 Fax www.sunlastmetal.com sales@sunlastmetal.com IMPORTANT NOTICE READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF
More informationFORTIFIED Home High Wind. Bronze New Roof Requirements
THE DECK (PREP MATERIAL, FASTENING) THE ROOF DECK SEALING THE ROOF DECK All existing roof cover and flashings shall be removed; deck shall be a clean, workable surface free from debris. Damaged or rotten
More informationSECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT
SECTION 07 30 05.01 SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT SPEC WRITERS NOTE: This specification includes materials and installation procedures for SlopeShield SA Self-Adhered Water-Resistive Vapor
More informationInstallation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile
Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME MATTERHORN Tile Watch detailed installation videos online at matterhornmetalroofing.com/tile-installation Table of Contents Accessories: Most
More informationOREGON ROOF CONSULTING - ROOF INSPECTION FORM
Oregon CCB: 199121 PO Box 220190, Milwaukie, OR 97222 Washington License: OREGORC871MR OREGON ROOF CONSULTING - ROOF INSPECTION FORM General Roof Conditions: NA = Not Applicable Debris on Roof Physical
More informationR PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.
R PANEL / PBR PANEL Installation, Flashings & Shop Drawing Detail Guide 901 W. Watkins Street Phoenix, AZ 85007 Phone: (877) 787-5467 (855) 426-7836 Email: sales@cortenroofing.com sales@metalforroofing.com
More informationInstallation Guide. Titan Slate. Rev102606
Installation Guide Titan Slate Rev102606 Titan Manufacturing 200 bella citta blvd. Davenport, fl 33897 Phone: (920) 716-1411 Fax: (866) 601-4395 www.titanroofsystems.com This document includes the recommended
More informationWESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.
WESTERN RIB Installation, Flashings & Shop Drawing Detail Guide 901 W. Watkins Street Phoenix, AZ 85007 Phone: (877) 787-5467 (855) 426-7836 Email: sales@cortenroofing.com sales@metalforroofing.com For
More informationSECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".
SECTION 07311 ASPHALT SHINGLE ROOFING SYSTEMS Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". PART 1 GENERAL 1.1 SECTION INCLUDES A. Granule surfaced asphalt shingle
More information* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.
is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.
More informationRoofing City of Owatonna BUILDING DEPARTMENT
Roofing City of Owatonna BUILDING DEPARTMENT 507-444-4370 www.ci.owatonna.mn.us This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code, City of Owatonna
More informationMargaret Greene Park Washroom Building 80 Westwood Road, Guelph, Ontario. Structural and Maintenance Remedial Work
SCOPE OF WORK Margaret Greene Park Washroom Building 80 Westwood Road, Guelph, Ontario Structural and Maintenance Remedial Work Prepared For City of Guelph City Hall, 1 Carden Street, Guelph, ON N1H 3A1
More informationProduct Guide Specification
Millennium Tiles, LLC March 2011 550 East Centralia Street Elkhron, WI 53121 Phone (262) 723-7778 Fax (262) 723-7629 Website www.millenniumtiles.com E-mail info@millenniumtiles.com Product Guide Specification
More informationRESIDENTIAL LIGHT GAUGE APPLICATION GUIDE
Our Name Says It All RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE Lebanon, PA 888.339.0059 Bridgton, ME 800.677.2060 Howe, IN 866.562.3782 www.everlastroofing.com Residential Light Gauge Table of Contents
More informationROOF DETAILS RD-0 CONSTRUCTION DOCUMENTS - AGENCY/ FEBRUARY 13, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.
ROOF DETAILS CONSTRUCTION DOCUMENTS - 350/ GENERAL PENNSYLVANIA CONSTRUCTION HOUSING PHASE FINANCE 1 AGENCY/ FEBRUARY 13, 017 RD-0 TERMINATION BAR AND SEALANT 1" STAINLESS STEEL METAL RIDGE COPING - PROVIDE
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2119 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00
More information2120 SW Poma Drive; Palm City, Florida Phone Fax
2120 SW Poma Drive; Palm City, Florida 34990 772-223-4055 Phone 772-781-7492 Fax www.sunlastmetal.com sales@sunlastmetal.com IMPORTANT NOTICE READ THIS MANUAL COMPLETELY BEFORE BEGINNING INSTALLATION OF
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:
0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-1188 Reissued 05/2018 Revised 08/2018 This report is subject to renewal 05/2019.
More informationCalculated Quantities and Details
Estimate # 8/14/2007 Estimate For: Bill Johnston Finest Quality Homes 1234 Heght Blvd #204 Houston Tx 77079- Ph: (281) 555-5555 Fax: (281) 555-5556 P.O. Box 323 Simonton Tx. 77476 Phone: (281) 346-2462
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More information3' COMMERCIAL RIB PREFORMED METAL SIDING
SECTION 07410 3' COMMERCIAL RIB PREFORMED METAL SIDING PART 1 GENERAL 1.01 DESCRIPTION A. Work in this section includes furnishing and installation, preformed steel ribbed siding on vertical portions of
More informationabout your house Before You Start Repairing or Replacing Roof Finishes Figure 1 Common problems
about your house CE 28 g Before You Start Repairing or Replacing Roof Finishes Leaky or damaged flashing Most roof leaks occur around penetrations such as chimneys. Moss Wide spaces All roofs need repair
More information4572 N Old US 31, Rochester, IN Toll Free: Fax: DETAIL MANUAL. and guide to Ramco Supply products
DETAIL MANUAL and guide to Ramco Supply products Metal Roofing and Siding Panels & Accessories 1 Ramco Supply s RAM Roofing Panels Ramco Supply s RAM panels are a strong, durable, economic, and attractive
More informationTESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS
TESTING APPLICATION STANDARD (TAS) No. 100-95 TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS 1. 2. Scope 1.1 This Protocol covers the determination of the water infiltration
More informationEngineering Services Program
Product Evaluation Engineering Services Program The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International Building
More informationStructural Criteria for Residential Rooftop Solar Energy Installations
Structural Criteria for Residential Rooftop Solar Energy Installations STEP 3 Expedited Structural Criteria Use of this document This toolkit document includes a list of structural criteria for over-the-counter
More informationbout your house before you start Repairing or Replacing Roof Finishes
A bout your house CE 28g before you start Repairing or Replacing Roof Finishes Leaky or damaged flashing Curling and cracking shingles Bare spots Most roof leaks occur around penetrations such as chimneys.
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -# Sunrise, Florida Phone
12 ZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -#43-307 Sunrise, Florida 33322 Phone 305-345-3793 E-Mail: peterizara@hotmail.com COURSE MATERIALS ROOFING COURSE WITH UPDATED MATERIALS
More informationSECTION BATTEN SEAM COPPER ROOFING
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 07 61 16 BATTEN SEAM COPPER ROOFING SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph as required
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationTYPICAL ROOF CONDITION LAYOUT
FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/
More informationDrexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood
Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
More informationNEW BEDFORD, MA, ARCHITECTS STAMP
NB BROOKLAWN SENIOR CENTER NEW BEDFORD, MA, 74 Jul 13, 28-11:32am T-100 TITLE SHEET.dwg DRAWINGS PREPARED FOR CITY OF NEW BEDFORD 133 WILLIAM ST NEW BEDFORD, MA, 740 ARCHITECT JM BOOTH & ASSOCIATES, INC.
More informationC. Jointing of Exterior Vertical Surfaces. Section D. The Secretary of the US Department of the Interior s Standards for Rehabilitation.
PART 1: GENERAL 1.01 Scope Of Standard A. This standard provides general guidance concerning the specific preferences of the University of Texas at Austin for roofing systems. B. UT recognizes that project
More informationCONTOUR CORRUGATED PANEL
CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details
More informationStanding Seam Installation Guide
Standing Seam Installation Guide Table of Contents Important Information... 3 Handling Material... 3 Delivering Material... 4 Mechanical Unloading... 4 Design Considerations... 4 Fastener Selection...
More informationFast Track Residential Re Roof Permit Checklist
Fast Track Residential Re Roof Permit Checklist ADDRESS I will abide by attached City Re Roofing Building Permit Required Guidelines. Attached is contractor s signed contract and, if applicable, the insurance
More informationThis public resource is maintained by Smart Home America and is available at: SmartHomeAmerica.org/resources/details/code-supplement
The Coastal Construction Code Supplement was created and adopted by community leaders and Building Code Officials in Coastal Alabama, in partnership with Smart Home America, after being impacted by both
More informationThermaCal Nail Base Roof Insulation Panels (all versions) Installation Instructions
ThermaCal Nail Base Roof Insulation Panels (all versions) Installation Instructions PRODUCTS a. ThermaCal 1 Ventilating Roof Insulation Panel is a venting nailable composite roof insulation panel with
More informationTEXAS RESIDENTIAL ROOFS
INSURANCE INSTITUTE FOR BUSINESS & HOME SAFETY BEST PRACTICES GUIDE Use this guidance to improve the long-term performance of your rf. In the spring of 2016, severe storms ripped through Texas, substantially
More informationTESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS
TESTING APPLICATION STANDARD (TAS) No. 100-95 TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS 1. 2. Scope 1.1 This Protocol covers the determination of the water infiltration
More informationTable of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5
Table of Contents Section Page Notes to Designer/User...................1-2 Map of Typical Roof Conditions..............3 Fastener Placement........................4 Fastener Selection.........................5
More informationMIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationSECTION STANDING-SEAM METAL ROOF PANEL
SECTION 074113 -STANDING-SEAM METAL ROOF PANEL PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2058 Reissued 06/2017 This report is subject to renewal 06/2018. DIVISION: 07 00 00 THERMAL
More informationVerea Spanish S Roof Tile Installation Guide
Verea Spanish S Roof Tile Installation Guide IDENTIFICATION OF ROOF AREAS RIDGE HIP FIELD OF ROOF RAKE (left) EAVE VALLEY GABLE END HEAD WALL SIDE WALL RAKE (right) DISCLAIMER NOTICE It is important to
More informationCS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
More informationPresents. Roofing Basics
Presents Roofing Basics Terminology Tile: A roof tile may be curved or flat piece of baked (at times glazed) clay or a synthetic material. It is the basic block used in covering roofs, walls, and floors.
More informationNon-Toxic Steel Roofs
Non-Toxic Steel Roofs The standard roof systems used in the United States can be a health problem for sensitive people. A steel roof can be an attractive alternative. This article covers new construction
More informationGOLD KEY INTERNATIONAL ROOFING DIVISION
Date: 6/17/15 John Hains 442 Orionvista Way Oakland FL 34787 Phone: (864) 508-0451 Email: jvhains@gmail.com Bid Price Includes: SHINGLE ROOF ~ Provide proper permitting and insurance. ~ Remove existing
More informationSECTION COMPOSITE ROOF TILE SYSTEMS
SECTION 07 30 00 COMPOSITE ROOF TILE SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof underlayment. B. Composite slate roofing. C. Composite shake roofing. D. Ventilation. E. Fasteners. F. Metal flashing.
More informationREPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2134 Reissued 12/2017 This report is subject to renewal 12/2018. DIVISION: 07 00
More informationWesleyan University 1.1 RELATED INFORMATION, DOCUMENTS AND REQUIREMENTS
Wesleyan University SCOPE OF WORK 346 WASHINGTON STREET ASPHALT ROOF REPLACEMENT PROJECT 23AB VINE STREET ASPHALT ROOF REPLACEMENT PROJECT 72 HOME NORTH SIDE ROOF REPLACEMENT 64 FOUNTAIN AVE ROOF REPAIR
More informationStructural Criteria for Residential Rooftop Solar Energy Installations
PV TOOLKIT PV TOOLKIT DOCUMENT #5 Structural Criteria for Residential Rooftop Solar Energy Installations Use of this document This toolkit document includes a one-page list of structural criteria for over-the-counter
More informationStructural Criteria for Residential Rooftop Solar Energy Installations
SWH TOOLKIT DOCUMENT #4 Structural Criteria for Residential Rooftop Solar Energy Installations Use of this document This toolkit document includes a one-page list of structural criteria for over-the-counter
More informationKBS-100 SNAP-LOCK PANEL & 5V PANEL I N S T A L L A T I O N M A N U A L
KBS-100 SNAP-LOCK PANEL & 5V PANEL I N S T A L L A T I O N M A N U A L KBS Metal Roofing KBS Metal Roofing General Information General Information Before beginning installation of panels, the installer
More informationAgenda. Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia
Decking & Fascia Agenda Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia 2 Chapter 7 Tools & Materials Tools for Decking Hammer Measuring Tape Chalk Line Speed Square Utility Knife Circular
More informationStructural Criteria for Residential Rooftop Solar Energy Installations
PV TOOLKIT DOCUMENT #5 Structural Criteria for Residential Rooftop Solar Energy Installations Use of this document This toolkit document includes a one-page list of structural criteria for over-the-counter
More informationLP OSB Sheathing & Structural 1 Sheathing
Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48
More informationShingle Asphalt Asbestos-cement Slate Wood, edge-grain Aluminum. Roll Roofing Mineral-surface 19" selvage edge Lowest Mineral-surface
ROOFING MATERIALS Roofing or roofing materials can be said to have two basic purposes. Primarily, a building is roofed to protect the structure and its contents from the effects of weather. Secondary to
More informationCentral Snap. Condition Details C SNAPDETAILS
Central Snap Condition Details D C SNAPDETAILS150612.2 The men and women at Central States Manufacturing, Inc. would like to welcome you. OUR MISSION Central States Manufacturing, Inc. is a 100% employee-owned
More informationROOF OWNER'S OPERATION AND MAINTENANCE MANUAL
ROOF OWNER'S OPERATION AND MAINTENANCE MANUAL Table of Contents Section Title Page Section 1.0 General Maintenance Statement 2 Section 2.0 Safety 2 Section 3.0 Inspections 2-4 Section 4.0 Repairs 4 Section
More informationROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION
ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)
More informationVerea Spanish S Roof Tile Installation Guide
Verea Spanish S Roof Tile Installation Guide IDENTIFICATION OF ROOF AREAS RIDGE HIP FIELD OF ROOF RAKE (left) EAVE VALLEY GABLE END HEAD WALL SIDE WALL RAKE (right) DISCLAIMER NOTICE It is important to
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER:
0 ICC-ES Report ICC-ES (800) 2-6587 (562) 699-05 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-286 Reissued 05/206 This report is subject to renewal 05/208. DIVISION: 07 00 00 THERMAL AND MOISTURE
More informationDESCRIPTION: Alucom, LLC NW 115 th Avenue Miami, FL Terrabella Classic Terrabella Verona Terrabella Shake
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590
More informationSTONE COATED METAL ROOF SHINGLE
GUIDE SPECIFICATION Manufacturer: A Fletcher Building Company 1230 Railroad Street Corona, CA 92882 951-272-8180 phone 951-272-4476 facsimile www.decra.com SECTION 07313 [07 31 13] STONE COATED METAL ROOF
More informationInsulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS
Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage
More informationIMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.
IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY WHIRLWIND BUILDING
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More informationSECTION CONCRETE ROOFING TILES ARCHITECTURAL SPECIFICATIONS VANDE HEY RALEIGH ARCHITECTURAL ROOF TILE
SECTION 07322 CONCRETE ROOFING TILES ARCHITECTURAL SPECIFICATIONS VANDE HEY RALEIGH ARCHITECTURAL ROOF TILE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including
More informationABSeam Panel Overview and Installation Instructions
82 Garden Spot Road Ephrata, PA 17522 717-445-6885 35 Ridge Road Newville, PA 17241 717-776-5951 ABSeam Panel Overview and Installation Instructions Applications: The ABSeam panel is an architectural panel
More informationSCOPE OF WORK BID TAB
Housing and Neighborhood Services of Rock Hill SCOPE OF WORK BID TAB Job # BID-CDBG #23 Bid is to be turn-key, including all applicable code requirements, materials, labor, City Business License permits,
More informationEuroshield Environmentally Friendly Rubber Roofing
Page1 Euroshield Environmentally Friendly Rubber Roofing Recommended installation procedures for EuroShake and EuroSlate Do not begin installation until you have read and fully understand the procedures
More information1 1/2" SSR. FABRAL The pursuit of excellence since 1967
1 1/2" SSR Detail Manual and Estimate Guide 16" 1 1 2" PROPER STORAGE When moisture remains in contact with Galvanized panels in the absence of freely circulating air, white, black or dark gray corrosion
More informationSIPs over a steel frame Raised SIP floor
DESIGNING WITH SIPS SIP APPLICATIONS SIP APPLICATIONS SIPs over a steel frame Raised SIP floor Custom log home SIP APPLICATIONS SIP APPLICATIONS SIPS VS. STICK FRAME SIPS VS. STICK FRAME STICK FRAME Stick
More information