KS SERIES - VERTICAL INSTALLATION
|
|
- Cathleen Bryant
- 6 years ago
- Views:
Transcription
1 CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV KS 45 EXPANDED PANEL JOINT CS-PJ-04-KSV KS 45 ENGAGED PANEL JOINT CS-PJ-05-KSV INTERMEDIATE SUPPORT CS-PJ-06-KSV LINER PANEL TO CONCRETE WITH SUPPORT CS-PJ-07-KSV LINER PANEL TO CONCRETE CS-BS-01-KSV BASE DETAIL - INSULATED SLAB HEAVY GAUGE ANGLE CS-BS-02-KSV BASE DETAIL - INSULATED SLAB LIGHT GAUGE Z CS-BS-03-KSV BASE DETAIL - PARTITION W/ FLOOR INSULATION CS-BS-04-KSV BASE DETAIL - INSULATED/NON-INSULATED CS-BS-05-KSV BASE DETAIL - PART. W/ CURBS INSULATED CS-BS-06-KSV BASE DETAIL - PART. NON-INSULATED CS-BS-07-KSV BASE DETAIL - LINER PANEL CS-BS-08-KSV BASE DETAIL - PART. W/ CURBS NON-INSULATED CS-BS-09-KSV BASE DETAIL - PART. W/ CURBS (ALTERNATE) CS-BS-10-KSV PARTITION BASE ON TOP OF CURB CS-OC-01-KSV OUTSIDE CORNER - FLUSH TRIM CS-OC-02-KSV OUTSIDE CORNER AT PARTITION CS-OC-03-KSV OUTSIDE CORNER LINER PANEL AT CONC WALL INDEX SHEET
2 CS-IC-01-KSV CS-IC-02-KSV CS-FO-01-KSV CS-FO-02-KSV CS-ST-01-KSV CS-RK-01-KSV CS-RK-02-KSV CS-EV-01-KSV CS-CE-01-KSV CS-CE-02-KSV CS-CE-03-KSV CS-CE-04-KSV CS-CE-05-KSV CS-CE-06-KSV CS-CE-07-KSV CS-CE-08-KSV CS-CE-09-KSV CS-CE-10-KSV CS-TL-01-KSV CS-TL-02-KSV CS-TL-03-KSV CS-TL-04-KSV INSIDE CORNER - FLUSH TRIM PARTITION TO EXTERIOR WALL HEADER CONDITION JAMB CONDITION STACK JOINT RAKE RAKE W/ MEMBRANE ROOF LOW EAVE INTERIOR WALL TO CEILING INTERIOR WALL TO CEILING - 'T' SECTION CEILING CHANNEL CEILING TEE CEILING TEE ASSEMBLY CEILING CHANNEL ASSEMBLY CEILING TO WALL - LONGITUDINAL CEILING TO WALL - TRANSVERSE PARTITION TO ROOF PARTITION TO ROOF WITH BLOCKING TRIM END LAP TRIM LAP WITH HEM TRIM END LAP WITH LAP STRIP TRIM LAP AT FRAMED OPENING INDEX SHEET
3 DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. REFRIGERATION EQUIPMENT IN COMBINATION WITH THE TEMPERATURE DIFFERENTIAL BETWEEN BUILDING EXTERIOR AND INTERIOR CAN CREATE NEGATIVE AIR PRESSURE WITHIN THE BUILDING (WARM AIR FROM OUTSIDE THE BUILDING IS DRAWN INTO THE BUILDING THROUGH AIR LEAKS IN THE BUILDING ENVELOPE). AS A RESULT, VAPOR SEALS ARE OF PRIMARY CONCERN TO PROPER COLD STORAGE PERFORMANCE. IN GENERAL, COLD STORAGE FACILITIES REQUIRE THE PRIMARY VAPOR BARRIER TO BE ON THE EXTERIOR (I.E. ), RATHER THAN INTERIOR SIDE OF THE PANEL. PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. ALL SEALANTS TO BE COMPATIBLE WITH VAPOR BARRIERS AS SHOWN COLD STORAGE DISCLAIMER
4 CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: (REFER TO PROFILE) INTERIOR: 26, 24, 22 MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH* INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" FEMALE JOINT INTERIOR FACE KS MINI WAVE (MW) SHADOWLINE MALE JOINT 2" - 6" EXTERIOR FACE MINI-WAVE (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) SHADOWLINE INTERIOR FACE FEMALE JOINT KS SL FLAT EXTERIOR FACE FLAT (26GA, 24GA, 22GA) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" SHADOWLINE INTERIOR FACE FEMALE JOINT KS GRANITSTONE/QUARTZ (GS) EXTERIOR FACE GRANITSTONE / QUARTZ (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE or FLAT EXTERIOR FACE (22GA ONLY) KS OPTIMO (OPE or OPS) 40" COVERAGE (24", 30", 36" OPTIONAL) OPTIONAL TRIMLESS ENDS FLAT 2" - 4" NOTE: MAX LENGTH: EMBOSSED: 32'-0" SMOOTH: 20'-0" KS SERIES PANEL PROFILES
5 CORE DEPTHS: 2", 2.5", 3", 4", 5", 6" STEEL GAUGES: EXTERIOR: (REFER TO PROFILE) INTERIOR: 26, 24, 22 MODULE WIDTH: 24", 30", 36", 42" PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH* INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" FEMALE JOINT INTERIOR FACE KS MINI WAVE (MW) SHADOWLINE MALE JOINT 2" - 6" EXTERIOR FACE MINI-WAVE (24GA, 22GA ONLY) 42" COVERAGE (36", 30", & 24" OPTIONAL) SHADOWLINE INTERIOR FACE FEMALE JOINT KS SL FLAT EXTERIOR FACE FLAT (26GA, 24GA, 22GA) 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE FEMALE JOINT KS GRANITSTONE/QUARTZ (GS) EXTERIOR FACE (24GA, 22GA ONLY) GRANITSTONE / QUARTZ 42" COVERAGE (36", 30", & 24" OPTIONAL) MALE JOINT 2" - 6" INTERIOR FACE SHADOWLINE or FLAT EXTERIOR FACE (22GA ONLY) KS OPTIMO (OPE or OPS) 40" COVERAGE (24", 30", 36" OPTIONAL) OPTIONAL TRIMLESS ENDS FLAT 2" - 4" NOTE: MAX LENGTH: EMBOSSED: 32'-0" SMOOTH: 20'-0" KS SERIES PANEL PROFILES
6 CORE DEPTHS: 2", 2.75", 3", 4", 5", 6", 8" STEEL GAUGES: EXTERIOR:26, 24, 22 INTERIOR: 26, 24, 22 MODULE WIDTH: " (45 3 8") PANEL ORIENTATION: VERTICAL EMBOSSING: EXTERIOR: STUCCO / SMOOTH INTERIOR: STUCCO / SMOOTH LENGTHS: MINIMUM: 8'-0" MAXIMUM: 53'-0" INTERIOR FACE SHADOWLINE MALE JOINT FEMALE JOINT EXTERIOR FACE KS SHADOWLINE INTERIOR (KSSLI) SHADOWLINE 2"-8" " (45 3 8") KS SERIES PANEL PROFILES
7 HORIZONTAL SUPPORT MALE LEG FEMALE POCKET 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY KS SERIES EXPANDED JOINT
8 HORIZONTAL SUPPORT MALE JOINT FEMALE JOINT PANEL MODULE 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER 1 8 " OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) WALL PANEL INSTALLATION DIRECTION KS SERIES ENGAGED JOINT
9 OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) MALE LEG FEMALE POCKET CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY KS 45 SERIES EXPANDED JOINT
10 (SPACING AS REQUIRED PER PANEL ANALYSIS) OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) (SPACING AS REQUIRED PER PANEL ANALYSIS) WALL PANEL INSTALLATION DIRECTION KS 45 SERIES ENGAGED JOINT
11 OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) MALE LEG FEMALE POCKET CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL * VERIFY FIRST PANEL ENGAGEMENT AND ADJUST ACCORDINGLY INTERMEDIATE SUPPORT
12 (SPACING AS REQUIRED PER PANEL ANALYSIS) OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) (SPACING AS REQUIRED PER PANEL ANALYSIS) WALL PANEL INSTALLATION DIRECTION LINER PANEL TO CONCRETE WITH SUPPORT
13 OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) INTERIOR OF BUILDING EXTERIOR OF BUILDING CONTINUOUS BUTYL SEALANT AT PANEL JOINT STRUCTURAL FRAMING (2) 1 4" - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT " 1" 3 4 " " 3 4 " 5 16 " Ø 5 16 " Ø STANDARD: 12 GA. STAINLESS STEEL TWO-HOLE HIDDEN FASTENER CLIP OPTIONAL: 12 GA. STAINLESS STEEL ONE-HOLE HIDDEN FASTENER CLIP NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS LINER PANEL TO CONCRETE
14 "Z" TRIM 2 BEADS OF BUTYL SEALANT ON EACH SIDE "Z" TRIM LAP TRIM MIN. 3" TRIM LAP SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS HEAVY GA. BASE ANGLE CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT BASE TRIM W/ POP 8" O.C. SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT CONTINUOUS "Z" TRIM SET IN BUTYL SEALANT (SEE LAP TRIM ABOVE FOR "Z" TRIM) CONCRETE CURB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE SLAB FIELD CUT THERMAL BREAK FLOOR INSULATION F.I.P INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT VAPOR BARRIER NOTES: 1) BASE ANGLE MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 2) BASE ANGLE GAUGE TO BE DETERMINED BY PROJECT ENGINEER OF RECORD 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED SLAB HEAVY GAUGE ANGLE
15 LAP TRIM 2 BEADS OF BUTYL SEALANT ON EACH SIDE SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) "Z" ANGLE LAP TRIM 3" END LAP 3" END LAP SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT BASE TRIM W/ POP 8" O.C. SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT CONTINUOUS "Z" TRIM SET IN BUTYL SEALANT (SEE LAP TRIM ABOVE FOR "Z" TRIM) HEAVY GA. BASE ANGLE CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE CURB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE SLAB FIELD CUT THERMAL BREAK FLOOR INSULATION F.I.P INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION CONTINUOUS BUTYL SEALANT W/ MARRIAGE BEAD TO VERTICAL PANEL JOINT VAPOR BARRIER NOTES: 1) BASE ANGLE MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 2) Z SHAPED BASE ANGLE GAUGE TO BE DETERMINED BY PROJECT ENGINEER OF RECORD 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED SLAB LIGHT GAUGE Z
16 SEALANT(OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT CONCRETE CURB (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT POURABLE SEALANT BASE TRIM 1 4 " - 14 STITCH 8" O.C. MIN. 14GA GALVANIZED STEEL BASE CHANNEL CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE SLAB F.I.P INSULATION FIELD CUT THERMAL BREAK STAGGERED FLOOR INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION VAPOR BARRIER NOTES: 1) TWO APPLICATIONS OF POURABLE SEALANT ARE REQUIRED. APPLY FIRST APPLICATION AND ALLOW 24HRS BEFORE APPLYING THE SECOND APPLICATION 2) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - PARTITION W/ FLOOR INSULATION
17 * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT BASE TRIM POURABLE SEALANT 1 4 " - 14" STITCH 8" O.C. MIN. 14GA GALVANIZED STEEL BASE CHANNEL CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE CONCRETE CURB CONCRETE SLAB FIELD CUT THERMAL BREAK F.I.P INSULATION FLOOR INSULATION SUB SLAB REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION VAPOR BARRIER NOTES: 1) TWO APPLICATIONS OF POURABLE SEALANT ARE REQUIRED. APPLY FIRST APPLICATION AND ALLOW 24HRS BEFORE APPLYING THE SECOND APPLICATION 2) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED/ NON-INSULATED FLOOR
18 CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) VAPOR BARRIER MAX. 12" O.C. BUTYL SEALANT W/ MARRIAGE BEAD OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) SLIP SHEET TO PROTECT PANELS BUTYL SEALANT BUTYL SEALANT MIN. 16 GA. GALVANIZED BASE CHANNEL FASTENER TO CONCRETE BASE DETAIL - PARTITION W/ CURBS INSULATED FLOOR
19 CONTINUOUS BUTYL SEALANT AT PANEL JOINT SLIP SHEET TO PROTECT PANELS SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) CONCRETE CURB CONCRETE CURB FINISH FLOOR CONCRETE SLAB * ENSURE THERMAL BREAK CUT IS DEEP ENOUGH TO CUT METAL AT PANEL JOINT SET PANEL IN CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT BASE CHANNEL F.I.P INSULATION FIELD CUT THERMAL BREAK STAGGERED FLOOR INSULATION SUB SLAB CONTINUOUS HEAVY BEAD OF BUTYL SEALANT FASTENER TO CONCRETE VAPOR BARRIER REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF BASE CONDITION NOTES: 1) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB 2) ANGLE IRON MAY BE USED IN LIEU OF CHANNEL BASE DETAIL - PARTITION NON-INSULATED FLOOR
20 OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO SEALANT AT PANEL JOINT MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE CONCRETE SLAB FASTENER TO CONCRETE BUTYL SEALANT BUTYL SEALANT (OPTIONAL) FLOOR INSULATION VAPOR BARRIER BASE DETAIL - LINER PANEL
21 OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL 8" O.C. BASE TRIM SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN - SEE SCHEDULE) CONTINUOUS BUTYL SEALANT AT PANEL JOINT (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP MIN. 16 GA. GALVANIZED BASE ANGLE BUTYL SEALANT W/ MARRIAGE BEAD TO JOINT SEALANT EXISTING EXTERIOR WALL BUTYL SEALANT (OPTIONAL) SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENER TO CONCRETE THIS DETAIL ASSUMES MINIMAL TEMPERATURE DIFFERENTIAL ON EITHER SIDE OF PANEL BASE DETAIL - PARTITION W/ CURBS (NON-INSULATED FLOOR)
22 CONTINUOUS BUTYL SEALANT AT PANEL JOINT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) MAX. 12" O.C. BUTYL SEALANT W/ MARRIAGE BEAD TO JOINT SEALANT MAX. 12" O.C. MIN. 16 GA. GALVANIZED BASE ANGLE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT BUTYL SEALANT (OPTIONAL) FASTENER TO CONCRETE THIS DETAIL ASSUMES MINIMAL TEMPERATURE DIFFERENTIAL ON EITHER SIDE OF PANEL BASE DETAIL - PARTITION W/ CURBS (ALTERNATE)
23 OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN - SEE SCHEDULE) 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT SLIP SHEET TO PROTECT PANELS (2) 1 4" - HEX HEAD FASTENERS PER PANEL CLIP ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) VAPOR BARRIER BUTYL SEALANT BUTYL SEALANT MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT PARTITION BASE ON TOP OF CURB
24 WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT MIN. 1 4" GAP FOR F.I.P. INSTALLATION FIELD CUT THERMAL BREAK SELF-ADHERING VAPOR BARRIER (AT - NOT BY KINGSPAN) REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END OUTSIDE CORNER TRIM F.I.P. INSULATION 1 4 " - 14 "LOW PROFILE" THROUGH 8' O.C. INSIDE CORNER TRIM POP 8" O.C. HORIZONTAL SUPPORT OUTSIDE CORNER - FLUSH TRIM
25 WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT MIN. 1 4" GAP FOR F.I.P. INSTALLATION FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END OUTSIDE CORNER TRIM F.I.P. INSULATION SELF-ADHERING VAPOR BARRIER (AT - NOT BY 8" O.C. INSIDE CORNER 8" O.C. OUTSIDE CORNER AT PARTITION
26 FASTENER TO CONCRETE OUTSIDE CORNER TRIM (PRE-INSTALL) TRANS FLASHING SELF-ADHERING VAPOR BARRIER (AT "WARM" - NOT BY KINGSPAN) FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO PANEL END INSIDE CORNER TRIM 3 4 " PHIL. PAN 8" O.C. F.I.P. 8" O.C. OUTSIDE CORNER LINER PANEL AT CONC WALL
27 WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD 8" O.C. CONTINUOUS BUTYL SEALANT OUTSIDE CORNER TRIM 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER W/ 1 1 8" BONDED WASHER FIELD CUT THERMAL BREAK REMOVE METAL SKIN FROM THERMAL CUT TO EXTENT OF CORNER CONDITION F.I.P. INSULATION MIN. 1 4" GAP FOR F.I.P. INSTALLATION 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER W/ 1 1 8" BONDED 8" O.C. HORIZONTAL SUPPORT POP 8" O.C. SELF-ADHERING VAPOR BARRIER INSIDE CORNER TRIM POP 8" O.C. INSIDE CORNER - FLUSH TRIM
28 8" O.C. EXTERIOR SELF-ADHERING VAPOR BARRIER INSIDE CORNER TRIM FIELD CUT THERMAL 8" O.C. INTERIOR PARTITION F.I.P. INSULATION EXPANSION FASTENER (TO BE LOCATED ON OPPOSITE SIDE OF THERMAL CUT FROM PANEL'S LEADING EDGE) OPTIONAL BUTYL AT WASH DOWN INSIDE CORNER 8" O.C. STRUCTURAL SUPPORT INTERIOR NOTES: 1) ADDITIONAL FASTENERS MAY BE REQUIRED ON EITHER SIDE OF THE FIELD CUT THERMAL BREAK BASED UPON ACTUAL DESIGN LOADS AND THERMAL REQUIREMENTS FIELD FILL WITH INSULATION INSULATE SUPPORTING STEEL ON OF PARTITION (APPROX. 4'-0") FIELD NOTCH PANELS AT GIRT LOCATIONS GIRT CAP TRIM PARTITION TO EXTERIOR WALL
29 OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) FREEZER DOOR CASING, FASTENERS, SEALANT, & REQUIRED SUPPORT SELF ADHERING VAPOR BARRIER (OPTIONAL - NOT BY KINGSPAN) CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO SEALANT AT PANEL JOINT HEADER CONDITION
30 SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SELF ADHERING VAPOR BARRIER (OPTIONAL - NOT BY KINGSPAN) FREEZER DOOR CASING, FASTENERS, SEALANT, & REQUIRED SUPPORT CONTINUOUS BUTYL SEALANT JAMB CONDITION
31 FIELD ROUT PANELS FOR WOOD SPLINE BASE TRIM WITH POP RIVETS (PRE-INSTALL WEEP HOLES) CONTINUOUS BUTYL SEALANT FIR SPLINE STACK JOINT TRIM WITH POP RIVETS SET FIR SPLINE IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT MARRIED TO SEALANT IN PANEL JOINT CONTINUOUS BUTYL SEALANT AT PANEL JOINT HORIZONTAL SUPPORT 14 GA. GALVANIZED HIDDEN CLIP (1 PER PANEL, PER GIRT) NOTES: 1) SEE DETAIL CS-TL-01-KSV AND CS-TL-02-KSV FOR PROPER TRIM LAP DETAILS 2) CONTACT KINGSPAN TECHNICAL SERVICES FOR PROPER PANEL FASTENING REQUIREMENTS STACK JOINT
32 GALVANIZED CAP FLASHING ROOF MEMBRANE SYSTEM ATTACHMENT ROOF MEMBRANE BOARD INSULATION AND ROOF UNDERLAYMENT ROOF MEMBRANE SYSTEM ATTACHMENT SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS FIELD CUT THERMAL BREAK SHEETING OR RAKE ANGLE REQUIRED F.I.P. INSULATION OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT AT PANEL JOINT RAKE
33 GALVANIZED CAP FLASHING ROOF MEMBRANE ROOF MEMBRANE SYSTEM ATTACHMENT CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT INSULATION AND ROOF UNDERLAYMENT FASTENER RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS SEALANT TO MEMBRANE FIELD CUT THERMAL BREAK F.I.P. INSULATION SHEETING OR RAKE ANGLE REQUIRED 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) RAKE W/ MEMBRANE ROOF
34 F.I.P. INSULATION GALVANIZED CAP FLASHING ROOF MEMBRANE ROOF MEMBRANE SYSTEM ATTACHMENT CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT INSULATION AND ROOF UNDERLAYMENT FASTENER RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS SEALANT TO MEMBRANE FIELD CUT THERMAL BREAK EAVE STRUT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT AT PANEL JOINT LOW EAVE
35 SEE CS-CE-04-KSV FOR ADDITIONAL INFO FIELD CUT THERMAL BREAK ATTIC ABOVE CEILING MUST BE VENTILATED F.I.P. INSULATION OUTSIDE CORNER TRIM CEILING SELF ADHERING VAPOR BARRIER WALL INSIDE CORNER TRIM CONTINUOUS BUTYL SEALANT AT PANEL JOINT INTERIOR WALL TO CEILING
36 #10 X 1 3 8" FASTENER AT EVERY PANEL JOINT BOTH SIDES OF PANEL AA CROSS SECTION (SECTION VIEW ) FIELD CUT THERMAL BREAK CEILING BUTYL SEALANT SUPPORT ANGLE EXPANSION FASTENER COMPRESSIBLE INSULATION A WALL A BUTYL SEALANT #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT (SEE DETAIL ABOVE) WALL TO CEILING INTERSECTION
37 ATTIC ABOVE CEILING MUST BE VENTILATED INSULATE HANGER RODS AS REQUIRED (NOT BY KINGSPAN) 3 8 " GALVANIZED HANGER ALL-THREAD ROD (ROD SPACING TO BE DETERMINED) TRANSITION FLASHING HEX NUT AND LOCK WASHER 4" X 4" X 14 GA. PLATE WASHER* SELF ADHERING VAPOR BARRIER INTERIOR FACE OF PANEL CEILING CEILING FILL 1 2" GAP BETWEEN PANEL WITH F.I.P. INSULATION HEX NUT AND LOCK WASHER EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION 1 1 2" X 6" X 14 GA. GALVANIZED CEILING CHANNEL (WHITE POWDER COAT - OPTIONAL) (CAP TRIM - OPTIONAL) #8 GA. SPLAY BRACE WIRE IN FOUR DIRECTIONS 3 8 " ALL-THREAD HANGER ROD FOUR TIGHT TURNS IN 1 1 2" SEISMIC BRACE PLATE * CONTACT KINGSPAN TECHNICAL SERVICES FOR SEISMIC BRACE PLATE QUANTITY AND LOCATION SEISMIC BRACE PLATE CEILING CHANNEL
38 ATTIC ABOVE CEILING MUST BE VENTILATED 3 8 " GALVANIZED HANGER ALL-THREAD ROD (SPACED NO GREATER THAN 6'-0" O.C.) TRANSITION FLASHING INSULATE HANGER RODS AS REQUIRED (NOT BY KINGSPAN) HEX NUT AND LOCK WASHER 4" X 4" X 14 GA. PLATE WASHER* SELF-ADHERING VAPOR BARRIER INTERIOR FACE OF PANEL CEILING CEILING EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION 4" X 3" X 3 16" EXTRUDED ALUMINUM CEILING TEE (WHITE POWDER COAT FINISH) FILL 1 2" GAP BETWEEN PANEL WITH F.I.P. INSULATION 3 8 "Ø EYE COUPLER NUT 3 8 "Ø x 1 1 2" BOLT WITH (3) 3 8 " WASHERS AND (1) LOCK-NUT PER BOLT BUTYL SEALANT #8 GA. SPLAY BRACE WIRE IN FOUR DIRECTIONS 3 8 " ALL-THREAD HANGER ROD FOUR TIGHT TURNS IN 1 1 2" SEISMIC BRACE PLATE * CONTACT KINGSPAN TECHNICAL SERVICES FOR SEISMIC BRACE PLATE QUANTITY AND LOCATION SEISMIC BRACE PLATE CEILING TEE
39 SEISMIC BRACE PLATE (IF REQUIRED) TO BE LOCATED AT EVERY THIRD ROD LOCATION IN LIEU OF PLATE WASHER (SEE DETAIL CS-CE-04-KSV). CONTACT KINGSPAN TECHNICAL SERVICES FOR VERIFICATION. OUTSIDE CORNER TRIM 12" OC. (SEALANT OR VAPOR SEAL TAPE AS REQUIRED) SEE DETAIL CS-CE-01-KSV FOR ADD'L INFO. PROJECT ENGINEER OF RECORD MUST VERIFY ROOF IS CAPABLE OF SUPPORTING CEILING SYSTEM LOADS AS WELL AS PROPER CEILING TO ROOF CONNECTION DETAILS LOCATE FIRST HANGER ROD AT LESS THAN 24" FROM FACE OF PANEL ERECTOR MAY PRE-ASSEMBLE HARDWARE ON 3 8" HANGAR RODS- WIRE TIES HOLD WASHERS ABOVE WORKING POINT CEILING TEE HEX NUT ROUND WSHR SPLICE PLATE 4" X 4" X 14 GA. PLATE WASHER WIRE TIE INTERIOR FACE OF PANEL CEILING TEE CEILING TEE SPLICE PLATE W/ (4) 3 8" X 1 1 2" BOLTS, NUTS, AND WASHERS EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION CEILING TEE ASSEMBLY
40 PROJECT ENGINEER OF RECORD MUST VERIFY ROOF IS CAPABLE OF SUPPORTING CEILING SYSTEM LOADS AS WELL AS PROPER CEILING TO ROOF CONNECTION DETAILS FIELD NOTCH END OF CHANNEL TO REST ON TOP OF WALL PANEL NUT ROUND WSHR ERECTOR MAY PRE-ASSEMBLE HARDWARE ON 3/8" HANGER RODS- WIRE TIES HOLD WASHERS ABOVE WORKING POINT 4" X 4" X 14 GA. PLATE WASHER WIRE TIE 2'-0" MAX. INTERIOR FACE OF PANEL SPLICE PLATE CEILING CHANNEL 9/16" DIA. HOLES PRE-PUNCHED FOR 3/8" OR ALL-THREAD ROD AT 5'-0" O/C (DO NOT SPACE ALL-THREAD RODS FURTHER THAN 60" APART. THE SPAN FROM WALL TO FIRST ROD, SHALL BE NO GREATER THAN 24".) EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION CEILING CHANNEL ASSEMBLY
41 ATTIC ABOVE CEILING MUST BE VENTILATED BUTYL SEALANT INSIDE CORNER TRIM FIELD CUT THERMAL BREAK F.I.P. INSULATION EXPANSION FASTENER CEILING CONTINUOUS BUTYL SEALANT AT "WARM" SIDE PANEL JOINT SUPPORT ANGLE NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR ENGINEERING ASSISTANCE CEILING TO WALL - LONGITUDINAL
42 ATTIC ABOVE CEILING MUST BE VENTILATED 3 8 " GALVANIZED HANGER ALL-THREAD ROD (ROD SPACING TO BE DETERMINED) BUTYL SEALANT INSIDE CORNER TRIM 1 4 " MAX DISTANCE BETWEEN PANEL EDGE AND THREAD ROD FIELD CUT THERMAL BREAK F.I.P. INSULATION EXPANSION FASTENER CEILING CONTINUOUS BUTYL SEALANT AT "WARM" SIDE PANEL JOINT 16 GA. SUPPORT ANGLE HEX NUT AND LOCK WASHER NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR ENGINEERING ASSISTANCE CEILING TO WALL - TRANSVERSE
43 A EXPANSION FASTENERS AS REQUIRED COMPRESSIBLE INSULATION SUPPORT ANGLE (SET IN BUTYL SEALANT) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT A PARTITION TO ROOF (PERPENDICULAR TO PURLIN) FIELD FILL WITH INSULATION FIELD NOTCH PANELS AT PURLIN LOCATIONS KINGSPAN TO SUPPLY FLAT-STOCK SHEETING TO BE FIELD FORMED FOR PANEL CLOSURES COMPRESSIBLE INSULATION PURLIN AA CROSS SECTION (SECTION VIEW -- TYPICAL AT EACH PURLIN) PARTITION TO ROOF
44 FILL VOIDS WITH FOAM BLOCK, SET IN BUTYL SEALANT FIELD CUT PANELS AS REQUIRED 1/4"-14 STITCH TEKS AT EACH PURLIN PURLIN CLOSURE TRIM TO BE FIELD CUT TO FIT AT PURLIN FLANGES. USE SILICONE TO SEAL ALL EDGES WHEN COMPLETE. 1/4"-14 STITCH TEKS AT EACH PURLIN SUPPORT ANGLE (SET IN BUTYL SEALANT) ATTACH PURLIN CLOSURES W/ POP RIVETS COMPRESSIBLE INSULATION PARTITION TO ROOF (WITH FOAM BLOCKING) (PERPENDICULAR TO PURLIN) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT FIELD CUT CONTINUOUS THERMAL BREAK (FREEZER ONLY) COMPRESSIBLE INSULATION EXPANSION FASTENERS AS REQUIRED SUPPORT ANGLE SET IN BUTYL SEALANT PARTITION TO ROOF (PARALLEL TO PURLIN) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT PARTITION TO ROOF WITH BLOCKING
45 (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP
46 FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM LAP WITH HEM
47 (2) BEADS BUTYL SEALANT 8" LONG LAP STRIP NOM. 1 4 " GAP TRIM END LAP WITH LAP STRIP
48 NOTE: DETAIL SHOWN IS FOR GENERAL USE ONLY (NOT FOR COOLER/FREEZER APPLICATIONS). SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY INTERIOR CAP TRIM AT HEAD EXPOSED SEALANT EXTERIOR CAP TRIM AT HEAD 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8" Ø WEEP HOLES INTERIOR JAMB TRIM 1 SILL TRIM WITH TABS BENT UP 6 3 EXTERIOR CAP TRIM AT JAMB FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXTERIOR CAP TRIM AT SILL FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED TRIM LAP AT FRAMED OPENING
200 / 300 SERIES PANELS COLD STORAGE
CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More information900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900
CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900
More informationKARRIER PANEL - BRICK
KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK
More informationPanel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing
EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing
More informationCOMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER
CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER CI-CFR-LG LEGEND CI-CFR-JT-01 PANEL JOINT CI-CFR-JT-02 PANEL JOINT SEQUENCE CI-CFR-JT-03 PANEL JOINT LAYOUT CI-CFR-SQ-01 PANEL INSTALLATION SEQUENCE
More informationTYPICAL ROOF CONDITION LAYOUT
FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05
More informationSUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)
1 5 32 " 2" 27 32 " REQUIRED FOR 1 1 4 " 113 32 " 2 21 32 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 12
More information4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)
REQUIRED FOR DETAIL 7 1 8 " 7 8 " SUSPENSION REQUIREMENTS SEE DETAIL B1.2 8" 7 1 1 8 " 4 " 2 1 8 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT
More informationNortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1
16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationFACE CFP - HORIZONTAL PANELS - OPTION 'B'
- Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF
More informationDesign No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1
FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"
More information12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS
CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More information6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.
5 7 8 " NOM. 2" TYPICAL SYSTEM SECTION VERTICAL SUPPORT SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP. CARRIER SPLICE SEE DETAIL B1.4 6" MAX CARRIER OVERHANG, TYP. 1 12 GA HANGER
More informationSPECIFICATIONS (unless noted otherwise)
2" 150F SYSTEM PROFILE 5 7 8 " NOM. CARRIER SPLICE SEE DETAIL B1.4 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 DETAIL 'A' TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 1 VERTICAL
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationInsulated Panels North America. KarrierPanel Universal Barrier Wall Solution
Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall
More informationMetafor Panel System Installation Guide
Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE
More informationDuct Wrap Flexible Wraps
Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone
More informationSECTION NON-STRUCTURAL METAL FRAMING
SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationFlushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide
Flushglaze 7500 For Steel Tube pplications and Horizontal Panels Façades Installation Guide September 2016 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal
More informationELEVATION FOR DETAIL REFERENCE ONLY
#smr_elev 5b SEC 2 8i SEC 2 33 SEC 4 1a SEC 2 37 SEC 4 36 SEC 4 35 SEC 4 SOFFIT FRONT 6d SEC 2 7a SEC 2 SOFFIT REAR INSIDE CORNER (REAR) OUTSIDE CORNER (FRONT) 10a SEC 2 9b SEC 2 4e SEC 2 ELEVATION FOR
More informationCOMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE
COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM
More informationELEVATION FOR DETAIL REFERENCE ONLY
8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08
More informationDesignwall 2000/4000. Façades Installation Guide
Designwall 2000/4000 Façades Installation Guide July 2017 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels and building envelope solutions. Insulated
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationSECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.
PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 13 34 00 FABRICATED ENGINEERED STRUCTURES A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationTABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers
version 2.5 updated as of 08.04.2017 2 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers 2.0 ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationFundamentals of Insulated Panel Installation. MBCEA 2016 Clearwater, FL
Fundamentals of Insulated Panel Installation MBCEA 2016 Clearwater, FL Fundamentals of Insulated Panel Installation Industrial Roof & Walls Not Architectural Not Cold Storage Topics Preparation Installation
More informationHOME SYSTEMS CONSTRUCTION PROCEDURE
HOME SYSTEMS WWW.QUICKBUILTHOMES.COM.AU CONSTRUCTION PROCEDURE INDEX - PARTS LIST PARTS LIST QBRC75(C) QBRM75C) QBSIPS75 QBRFSZ75C QBRFBC75C QBRF3030G QBRGSQC QBRFRC75C QBRFZEC QBRF4040C QBSACC75 QBFR7330WC
More informationTable of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5
Table of Contents Section Page Notes to Designer/User...................1-2 Map of Typical Roof Conditions..............3 Fastener Placement........................4 Fastener Selection.........................5
More informationPRESTON HEALTH SERVICES ARCHITECT'S NO. 2700
SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA
Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION ACOUSTICAL PANEL CEILINGS
SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationFilled Cavity (FC) / Long Tab Banded Installation Instructions
Installation Instructions Installation Instructions Materials Required: Faced Fiberglass Insulation with Extended Tabs - Supplied in widths to match purlin spaces and lengths approximately 2 feet longer
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationWeatherSmart Air Barrier Installation Guide
WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material
More informationLight-Metal Roof Edge, Raised
NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL
More informationThin Brick Façade. Façades Installation Guide
Thin Brick Façade Façades Installation Guide October 2016 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels. Insulated panels serve as energy efficient,
More informationAnchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi
STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel
More informationELEVATION FOR DETAIL REFERENCE ONLY
4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS
More informationCommercial Flashing Details
This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from
More informationWARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More information* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.
is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.
More informationAXIOM Building Perimeter System Assembly and Installation Instructions
CEILING SYSTEMS AXIOM Building Perimeter System Assembly and Installation Instructions 1 GENERAL 1.1 Description Axiom Building Perimeter Systems (ABPS) is a pre-engineered perimeter solution to accomplish
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationSECTION PRE-ENGINEERED METAL BUILDING
SECTION 13121 PRE-ENGINEERED METAL BUILDING PART 1 GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to design, fabricate, deliver to project site, and erect
More informationSECTION PRE-ENGINEERED BUILDING INSULATION
PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered
More informationInstallation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier.
www.quakerwindows.com www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines for all Quaker products with nail fins New
More informationRS32 Multi-Section Skylight System under/over seam clip double diverter
INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series
More informationCONTOUR CORRUGATED PANEL
CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details
More informationInstallation Instructions
Installation Instructions 400SS Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised June 2016 dependable@tubeliteinc.com Page 1 TABLE OF
More informationSECTION METAL BUILDING SYSTEMS
SECTION 13 3419 PART 1 GENERAL 1.01 SECTION INCLUDES A. Manufacturer-engineered, shop-fabricated structural steel building frame. B. Insulated Metal wall and roof panels including gutters and downspouts.
More informationPrestige Series 12. Installation guide
Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................
More informationDivision 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11
07 21 16 Blanket Insulation Page 1 of 11 Unifrax I LLC Design No. UNI/BI 120-14 FIRE RESISTANT GREASE DUCT FyreWrap Elite 1.5 Duct Insulation ASTM E 2336-16 and ICC-ES Acceptance Criteria for Grease Duct
More informationSECTION GYPSUM BOARD PART 1 - GENERAL
SECTION 09250 - GYPSUM BOARD PART 1 - GENERAL 1.01 DESCRIPTION: A. Work under this section is subject to requirements of the Contract Documents including the General Conditions and Supplementary Conditions
More informationMID-RISE DESIGN & CONSTRUCTION
TECHNICAL BULLETIN No.38-021616 Rev072116 MID-RISE DESIGN & CONSTRUCTION Logix effective R-values range from R-24 to R-28+ Insulated concrete forms (ICF) are becoming a main stream choice for the construction
More informationSECTION GYPSUM BOARD ASSEMBLIES
SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.
More informationProject No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6
DECEMBER, 2016 Page 1 of 6 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 07 21 16 - Batt and Blanket Insulation..3 Section 07 92 10 - Sealants..4 Section 09 91 00
More informationWEC Manufacturing Phone: (901) Website: Itswec.com
All Welded Plus Series Part 1: General 1.1 Construction Requirements: All lockers shall be powder coated steel as design and manufactured by WEC, Memphis, Tennessee. WEC will furnish all labor and materials
More informationINSULATED PANEL OVERVIEW
INSULATED PANEL OVERVIEW Our various series of wall and roof panels are filled with non CFC polyisocyanurate foam. The panels are manufactured in a uniform pressure laminating process that bonds metal
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationDETAIL INSTRUCTION No. 1
BEFORE BEGINNING INSTALLATION, PLEASE READ THROUGH ALL INSTRUCTIONS. Uncrate shipment and check against packing list to insure all materials are included before beginning installation. If any discrepencies
More informationSUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:
IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:
More information1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.
SECTION 09 2216 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More informationLLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS
Installation and Maintenance Instructions 1-1/2 Hour Rated, UL Classified model 75 fire dampers For use in fire barriers with ratings of less than 3 hours INSPECTION 1. Inspect for shipping damage. 2.
More informationStandard Installation Fire Damper Models: 119, 119(F), 119(SS), D19
Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the
More informationSECTION GYPSUM BOARD
SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable
More information1.52mm 1.52mm. Exterior Siding Sheet: Fabricated from Z275 steel material conforming to ASTM A653M grade 230 steel
.0 EXTERIOR SKIN PROFILES: A. SHADOWLINE - 68mm (46") PANEL MODULE.0 EXTERIOR SKIN PROFILES: B. MICRORIB - 68mm (46") PANEL MODULE 02mm 25mm 02mm EXPOSED SURFACE 38.mm 38.mm 38.mm EXPOSED SURFACE.52mm.52mm
More informationStudent Services & Classroom Addition
SECTION 095133 - ACOUSTICAL METAL PAN CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied
More informationINSTALLATION MANUAL KOCH
INSTALLATION MANUAL KOCH TECHNICAL SYSTEMS GROUP PRE-FAB ACOUSTICAL/THERMAL PANELS AND ENCLOSURES GEORGE KOCH SONS, LLC TECHNICAL SYSTEMS GROUP 10 South Eleventh Avenue Evansville, Indiana 47744 812-465-9600
More informationContainer Installation Guide
Container Insulation Container Installation Guide Panels and Inserts The InSoFast CX Container panel and the Inserts are designed to fit most shipping containers. Containers have three types of corrugations:
More informationRS24-10 Single-Section Skylight System
INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980
More informationNCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance
More informationCEILING & WALL SYSTEMS
CEILING & WALL SYSTEMS Axiom Perimeter Trim Commercial Ceilings and Walls Solutions Guide Axiom Perimeter Trim AXIOM Trim The Axiom family of products provide functional and visual options in ceiling design.
More informationTechnical Data Sheet
Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.
More informationFIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5
Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a
More informationDivision 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17
07 21 16 Blanket Insulation Page 1 of 17 Design Number UNI/BI 120-03 FIRE RESISTANT GREASE DUCT Unifrax I LLC FyreWrap Elite 1.5 Duct Insulation CAN/ULC S144 Fire Resistance Rating 2 hours Fire Inside
More informationPATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge
Assembly Manual 8x5 PATENTS ARE PENDING Approximate Size 7980303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth
More informationGARAGE MAIN FLOOR PLAN
12'-0" 4'-6" 3'-0" 4'-6" 3040 14'-0" LADDER LT LINE BUNK CABIN 11'-4" x 13'-4" 14'-0" BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS.
More informationUltra Wall System. CAD Detail Sets
Ultra Wall System CAD Detail Sets Contents Page UWS-CM CAVITYMATE Ultra Contents 1-0 FOR: Details continuing on 1-1 thru 1-17 Cavity cut XPS board to fit between ladder tie masonry ties in CMU walls UWS-SL
More informationBENCHMARK Evolution Axis
Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL
More informationHip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation
Hip Detail Hip Detail STANDARD Mineral fibre insulation ENHANCED Hip flashing with 150mm sealed butt straps Panels site cut to suit rake angle Apex dam (Ref: LP1/A) Rake cut profiled filler sealed top
More informationThe Olympia Difference
The Olympia Difference Valued Customer, Thank you for choosing Olympia Steel Buildings as the solution to your building needs. You can be confident that the Olympia team of professionals will provide you
More informationChapter 32 - Garage. June 2015 Garages 32-1
Chapter 32 - Garage Contents Chapter 32 - Garage... 32-1 Foundation... 32-3 Walls... 32-3 Roof Framing... 32-4 Roofing... 32-4 Exterior Dow Board... 32-5 Doors... 32-5 Siding... 32-5 Gutters... 32-6 Painting...
More informationProper Installation of Insulated Metal Wall Panels
Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also
More informationSECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.
SECTION 06 1100 WOOD FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But
More informationA. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.
SECTION 13125 - METAL BUILDING SYSTEMS PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall. 1. Eave Height: 13-0
More informationPATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge
Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth
More informationELEVATION FOR DETAIL REFERENCE ONLY
5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX
More information