1 Tech Solutions WEATHERMATE Straight Flashing Commercial Installation Guide

2 Table of Contents Product Overview Benefits of Detailed Window Flashing Installation on Flat Surfaces Outside Corner Flashing Inside Corner Flashing Fenestration Flashing Recommendations Wall Penetrations Common Installation Errors Flashing Details

3 Product Overview This document describes how to use WEATHERMATE Flashing Tape to create an air and weather barrier layer by sealing the insulation board joints and through wall penetrations in a wall assembly. This applies only to tested Dow wall assemblies that include THERMAX and/or STYROFOAM Extruded Polystyrene Foam Insulation products. For more information on the THERMAX Wall System, visit For more information on Ultra Air Barrier Wall System visit WEATHERMATE Straight Flashing combines a tough plastic film facer with a 20 mil butyl rubber adhesive that offers a strong bond to foam, most sheathing facers, wood, metal and masonry and concrete. A polymeric-coated paper release liner on the flashing offers easy application. WEATHERMATE Straight Flashing should be installed on clean, dry, frost-free surfaces. Before application, surfaces should be cleaned to remove moisture, dirt, dust, grease/oils and other contaminants that may limit adhesion. Remove sharp protrusions in surfaces to avoid punctures in the flashing. When installing the WEATHERMATE Straight Flashing on substrates where the adhesion may not be optimum, apply a spray adhesive such as 3M High Strength 90 on the substrate before application. Minimum application temperature for WEATHERMATE Straight Flashing is 25 F (-4 C). WEATHERMATE Straight Flashing should not be stretched or pulled as it is applied. This can cause wrinkles and can also result in the facer shrinking back to its original length which will expose some adhesive on the ends of the tape. WEATHERMATE Straight Flashing may be left exposed to sunlight for up to 180 days before covering with the exterior cladding. A general installation guide for WEATHERMATE Flashing Tape cannot cover every possible scenario in which it would be used to seal the wall system against air and water penetration. In all cases, flashing tape should be thought of as a bridge to seal the gaps between insulation boards or between insulation boards and a penetration such as a door or window. If a question arises on how to seal a given penetration, consider using the flashing tape to create a continuous waterproof line of defense from the sheathing to the waterproof portion of the penetrating element. This line can also include liquid sealants such as polyurethane or silicone. Always wear personal protective equipment, including gloves and safety glasses, and use safe work habits during building and construction projects. For more information on WEATHERMATE Flashing Tape visit Benefits of Detailed Window Flashing Proper window flashing is critical because it diverts water that may get behind the exterior cladding to the exterior of the building. Water tightness of the windows is critical in ensuring full performance of the building envelope. The window flashing is also part of the air barrier system that reduces air leakage into the building. Improper installation and faulty design details for flashing can result in water leakage, mold, warping, and eventually structural damage requiring costly repairs. 3

4 Installation on Flat Surfaces To install the WEATHERMATE Straight Flashing, cut the material into pieces (approximately 5' in length) that can be easily applied in a straight and true manner to maintain coverage and overlaps without wrinkles. Flashing may be cut with a utility knife or cutting shears. Use safe cutting practices and wear protective equipment including gloves. Peel back the release paper from the butyl backing about 12 inches and position the material so that it is aligned in the direction and location in which it will be placed. If this is on an insulation board joint, it should be parallel to the joint that you want to seal and lapped equally on both sides of the joint (See Image 1). Press the first inch of the material onto the substrate to secure the material in place (See Image 2). Keeping the strip in place, peel back the release paper and press/smooth the flashing into place moving along the joint. Proper adherence of the flashing to the substrate is best achieved by working the adhesive onto the substrate using a smoothing tool like a roller or a flat piece of plastic to ensure a complete seal and strong bond. Smooth out all air bubbles and wrinkles (See Image 3). Flashing should always be lapped in a water shedding (ship-lapped or shingle) fashion starting from the lowest point. This means that you start from the bottom of the wall and work your way up. By having the top piece of flashing placed over the bottom piece, you will help shed the water as it drains down the face of the materials serving the function as a water resistive barrier (See Image 4). Image 1 Image 2 Roller Smoothing Tool Flat Plastic Smoothing Tool Image 3 Image 4 4

5 Outside Corner Flashing Select the width of WEATHERMATE Straight Flashing that will cover at least 2 of the sheathing at each side of the corner plus the exposed butt end of the insulation. Starting from the bottom working up in water shedding shingle fashion, apply WEATHERMATE Straight Flashing first to one side of the external corner. Make sure that this is fully applied and worked into the surface of the insulation along the entire length of the piece of flashing tape. Then fold over and adhere to the adjoining sheathing surface covering a minimum of 2 of the sheathings surface (See Images 5a and 5b). Image 5a Image 5b Flashing lap joints should be a minimum of the width of the flashing. Be sure to firmly smooth over the underlying flashing to eliminate the potential bridge gaps and channels. For example, If you are using 4 inch (100 mm) wide material, then install the material with a 4 inch (100 mm) overlap and when using a 6 inch (150 mm) wide material, then install the material with a 6 inch (150 mm) overlap (See Image 6). Image 6 5

6 Inside Corner Flashing Starting from the bottom working up in water shedding shingle fashion, apply a vertical piece of WEATHERMATE Straight Flashing first to one side of the internal corner. This is a more difficult installation than an external corner because the second half of the flashing must be kept from prematurely adhering to the second insulation surface avoiding an unadhered bridge across the corner seam (See Image 6a). Make sure that the first side is fully applied and worked into the surface of the insulation along the entire length of the piece of flashing tape. Use a smoothing tool to ensure that the flashing is installed all the way into the corner (See Image 6b and 6c). Then fold over and adhere to the adjoining sheathing surface covering a minimum of 2" (+/- 1/2" tolerance) of that sheathing s surface. A plan view of installing vertical WEATHERMATE Straight Flashing on an inside corner. Incorrect Correct Image 6a Image 6b Image 6c Always terminate the horizontal flashing at all corners, specially inside corners (See Image 7a). Start a new piece of flashing tape on the adjacent side of the corner. DO NOT bridge the corner as this can result in the flashing slightly pulling away from the insulation substrate which would compromise the water barrier qualities of the system (See Image 7b). Image 7a Image 7b 6

7 Fenestration Flashing Recommendations Non-Flanged Block Frame Step 1. Prepare opening and ensure surfaces are clean, dry and smooth. Select the flashing width that will cover a minimum of 2" (+/- 1/2" tolerance) of the structural wall, plus sheathing thickness, plus an additional 2" minimum (+/- 1/2" tolerance) overlap on the sheathing surface. Note: You will need to use 6" wide flashing tape for almost all situations, or even 9" wide flashing tape if the sheathing is more than two inches thick. Step 2. Cut two flashing strips 12" long and apply them into each of the opening lower corners so that a minimum of 2" (+/- 1/2" tolerance) of flashing can overlap the sheathing and a minimum of 2" (+/- 1/2" tolerance) can overlap on to the structural wall. Make sure to work the flashing onto the surface of the structural wall. When applying the flashing tape into the corner of the window, do not allow the flashing to bridge the corner, creating an air gap and a weak point in the flashing. Instead, work the flashing completely into the corner from one side with a plastic smoothing tool. Only after the flashing is seated firmly in the very edge of the corner should the remaining flap of flashing be applied onto the remaining face of the corner (See Image 8). Image 8 Step 3. Make two relief cuts near the corner of the installed flashing tape (Image 8a). Carefully fold the long sides of the flashing tape resulting from the cuts onto the sheathing surface (Image 8b). Then fold the corner tab created by the cuts onto the sheathing surface (Image 8c). Work the flashing tape onto the sheathing surface (Image 8d). Image 8a Image 8b Image 8c Image 8d 7

8 Fenestration Flashing Recommendations (continued) Step 4. Cut a flashing strip the width of the opening plus 2 widths of the flashing. Center the flashing piece horizontally across the bottom of the opening and apply to the wall so that a minimum of 2" (+/- 1/2" tolerance) will cover the sheathing below the opening. After this piece is installed and worked onto the insulation, cut the flashing at each side of the opening. Fold the resulting flap down onto the insulation and structural wall of the opening taking care to make sure there are no folds or bubbles. This flap must extend at least two inches onto the structural wall (See Images 9a, 9b and 9c). Image 9a Image 9b Image 9c Step 5. Apply jamb flashing to the side of the opening. This procedure is very similar to Step 4. Cut two flashing strips the height of the opening plus 2 widths of the flashing. Starting with one side, center vertically and apply to the wall so that a minimum of 2" (+/- 1/2" tolerance) will cover the sheathing along each jamb in the opening. After this piece is installed and worked onto the insulation, cut the flashing at each side of the opening. Fold the resulting flap down onto the insulation and structural wall of the opening taking care to make sure there is no fold or bubbles. This flap must extend at least 2 onto the structural wall. Repeat on the other side of the opening (See Images 10a, 10b, 10c and 10d). Image 10a Image 10b Image 10c Image 10d 8

9 Fenestration Flashing Recommendations (continued) Step 6. Apply header flashing. This is done is a manner identical to the base and jamb flashings described in the previous steps. Cut a flashing strip the width of the opening plus 2 widths of the flashing. Center horizontally and apply to the header so that a minimum of 2" (+/- 1/2" tolerance) will cover the sheathing above the opening. After this piece is installed and worked onto the insulation, cut the flashing at each side of the opening. Fold the resulting flap onto the insulation and structural wall of the opening taking care to make sure there is no fold or bubbles. This flap must extend at least 2 onto the structural wall. Step 7. Install fenestration per manufacturers guidelines. Step 8. Seal fenestration exterior perimeter per fenestration manufacturers recommendations. A high quality construction sealant which is designed to adhere to smooth surfaces should be used. DOW CORNING 758 SILICONE WEATHER BARRIER SEALANT is an example of a product designed for adhering to low energy or slippery surfaces common in sheet or peel and stick weather resistant barriers. Step 9. Seal any gap between the window frame and the structural wall with an approved sealant. Seal void spaces on the interior side around the window using GREAT STUFF PRO Window & Door Insulating Foam Sealant** (See Image 11). Image 11 9

10 Wall Penetrations Penetrations through the wall system, such as ducts or pipes, also need to be sealed to maintain the weather barrier integrity across the entire envelope. Square Penetrations Install strips of flashing on all four sides, starting at the bottom, then down the sides and finish by installing a strip along the top. The strips of WEATHERMATE Flashing shall be positioned so that the flashing overlaps the THERMAX (ci) Exterior Insulation by 2 (+/- 1/2" tolerance) (50 mm) and the penetration by 2 (+/- 1/2" tolerance) (50 mm). Install the bottom strip by folding it in half along the long dimension, and pressing one half of the strip against the sheathing. Use a smoothing tool to get the tape pressed into place all the way into the corner. Then fold the other half against the penetration (See Image 13). Image 13 Cut the flashing tape along the edge of the penetration and fold the resulting flap back against the sheathing and smooth into place (See Image 14). Image 14 Follow this same procedure for each side of the penetration making sure to work the flashing into the very corner of the penetration prior to folding over the flap of flashing tape (See Image 15). Repeat this procedure for the top of the penetration to complete the flashing process. Image 15 Note: If the gap between the duct and the opening is over 1, fill the space between the duct and the opening with foam sealant (either GREAT STUFF Big Gap Filler Insulating Foam Sealant** or FROTH-PAK Foam Sealant**). After the foam sealant has fully set, trim the excess foam flush with the opening per manufacturer s recommendations and apply the WEATHERMATE Flashing tape as outlined above. Choose the width of the flashing tape to ensure the flashing tape extends at least 2 onto the duct and 2 onto the wall sheathing. **Consult label and Material Safety Data Sheet carefully before use. 10

11 Round Penetrations Round penetrations are flashed with a slightly different method than those described above. Step 1. Seal the space between the penetration and the wall using a single component foam sealant such as GREAT STUFF PRO Insulating Foam Sealant.** Trim off any excess per installation instructions (See image 16). Image 16 Step 2. Apply either WEATHERMATE Straight Flashing Tape or Flexible Flashing Tape to complete the sealing process. When using WEATHERMATE Straight Flashing Tape, cut a piece of 9 inch wide tape the same length as the circumference of the penetration. Along one side of the flashing, make cuts in the flashing spaced 1 (25 mm) apart. Install flashing against the THERMAX (ci) Exterior Insulation with one edge up against the penetration. As you do this, the flashing will fan out as it curves around the penetration. Cover the spaces between the splayed out flashing with additional pieces of straight flashing applied shingle style around the opening (See Image 17). Image 17 When using WEATHERMATE Flexible Flashing Tape, wrap two pieces of flashing tape around the bottom and then the top of the penetration. Wrap the inner portion of the flashing onto the penetrating object itself (See Image 18). Image 18 **Consult label and Material Safety Data Sheet carefully before use. 11

12 Common Installation Errors Flashing Application (Do s and Don ts) Example 1 - Applying Flashing Tape to Inside Corners What TO DO: When possible, cut flashing pieces in no longer than 4 foot sections Press the flashing into one side of the corner first - adhering it completely on one side and pushing it as far as possible into the corner. Then press the remaining side onto the adjacent surface. Be careful to press tightly in the corner and avoid bridging the angle In areas where a vertical seal can be applied, always apply the vertical piece first (less potential for shrinkage and bridging with a vertical piece). The horizontal piece can be cut at the intersection and sealed to the vertical flashing face What NOT to do: Do NOT apply from right to left and across the angle. Do NOT over stretch the flashing tape (this can result in poor adhesion and bridging effect) This applies to inside and outside corners Example 2 Stretching of tape What TO DO: Smooth the tape so it adheres properly to the substrate Make sure the edges of the tape are properly adhered What NOT to do: Do NOT stretch the tape stretching results in wrinkles, lack of adhesion to substrate, and tape facer shrinking back to its original dimension, exposing the butyl adhesive on some edges CORRECT INCORRECT 12

13 Example 3 Loose Edges & non coverage over caps What TO DO: ALWAYS press out the flashing piece ensuring entire surface area is adhered to insulation facer In areas where there are non flush materials such as fastener caps, ensure that you have a minimum of 1 overlap of tape on the joint and fastener cap Default to a wider flashing tape if overlap cannot be achieved Smooth the tape so it adheres properly to the substrate What NOT to do: Do NOT leave edges of tape unadhered. This can lead to water intrusion into the wall system Do NOT flash over items without providing the proper amount of overlap. In the example above, the fastener cap is not completely covered, allowing for a gap to be formed for water intrusion Do NOT stretch the tape stretching results in wrinkles, lack of adhesion to substrate, and tape facer shrinking back to its original dimension, exposing the butyl adhesive on some edges Example 4 External Strapping What TO DO: Always apply good building science techniques and effect to provide proper water drainage properties What NOT to do: Do NOT apply flashings over top of other wall components when it can be avoided Example 5 Common Sense Do NOT apply flashings over top of uneven surfaces Do NOT apply flashing over top of materials such as caulking, spray foam and foam sealants without trimming the material to ensure proper adhesion and water drainage properties Do NOT install the tape on a wet or dusty surface this results in improper adhesion of the tape to the substrate. 13

14 Flashing Details The detail in the figure above has been tested to verify installation with the THERMAX Wall System based on stringent external water evaluations through the Testing Method -ASTM E547 Standard Test method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls and E331, at the National Certified Testing Laboratory 14

15 This detail is also recommended to be used with the THERMAX Wall System, but it has not been externally tested. 15

16 For Technical Information: BLUE (2583). For Sales Information: THE DOW CHEMICAL COMPANY. Dow Building Solutions. 200 Larkin. Midland, MI Illustrations are not intended to replace the need for design by appropriate professionals such as architects or engineers. NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document. References to Dow or the Company mean the Dow legal entity selling the products to Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. STYROFOAM Brand Extruded Polystyrene Foam Insulation CAUTION: This product is combustible. Protect from high heat sources. A protective barrier or thermal barrier may be required as specified in the appropriate building code. For more information, consult MSDS, call Dow at BLUE (2583) or contact your local building inspector. In an emergency, call Dow Polyisocyanurate Insulation CAUTION: This product is combustible and shall only be used as specified by the local building code with respect to flame spread classification and to the use of a suitable thermal barrier. For more information, consult MSDS, call Dow at BLUE (2583) or contact your local building inspector. In an emergency, call GREAT STUFF PRO Insulating Foam Sealant products contain isocyanate and a flammable blowing agent. Read the label and Material Safety Data Sheet carefully before use. Eliminate all sources of ignition before use. Wear long sleeves, gloves, and safety glasses or goggles. Provide adequate ventilation or wear proper respiratory protection. Contents under pressure. FROTH-PAK Spray Polyurethane Foam contains isocyanate, hydrofluorocarbon blowing agent and polyol. Read the instructions and Material Safety Data Sheets carefully before use. Wear protective clothing (including long sleeves), gloves, goggles or safety glasses, and proper respiratory protection. Do not breathe vapor or mist. Use only with adequate ventilation. It is recommended that applicators and those working in the spray area wear respiratory protection. Increased ventilation significantly reduces the potential for isocyanate exposure, however, supplied air or an approved air-purifying respirator equipped with an organic vapor sorbent and a particulate filter may still be required to maintain exposure levels below ACGIH, OSHA, WEEL or other applicable limits. For situations where the atmospheric levels may exceed the level for which an air-purifying respirator is effective, use a positive-pressure, air-supplying respirator (air line or selfcontained breathing apparatus). Spraying large amounts of foam indoors may require the use of a positive pressure, air-supplying respirator. Contents under pressure. WARNING: Rigid foam insulation does not constitute a working walkable surface or qualify as a fall protection product. Building and/or construction practices unrelated to building materials could greatly affect moisture and the potential for mold formation. No material supplier including Dow can give assurance that mold will not develop in any specific system. Dow Polyurethane Foam Insulation and Sealants CAUTION: When cured, these products are combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240ºF (116ºC). For more information, consult MSDS, call Dow at BLUE (2583) or contact your local building inspector. In an emergency, call in the U.S. or in Canada. Printed in U.S.A. Trademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No MCK MCK McKAY216510

TECH SOLUTIONS A Prescriptive Solution to Meet Air Barrier Energy Code Requirements in Metal Buildings

TECH SOLUTIONS A Prescriptive Solution to Meet Air Barrier Energy Code Requirements in Metal Buildings A Prescriptive Solution to Meet Air Barrier Energy Code Requirements in Summary The best approach to long-term energy efficiency is to increase insulation levels and reduce air infiltration through the

More information

TECH SOLUTIONS THERMAX Insulation in Low Humidity Metal Buildings

TECH SOLUTIONS THERMAX Insulation in Low Humidity Metal Buildings Summary Low humidity metal buildings are used in the commercial to industrial construction markets and include factories, warehouses, agricultural structures, cold storage structures and similar facilities.

More information

Foam Vs Fiber. Air Sealing Benefit of Foam in Single Family Residential New Construction. Gary Parsons Fellow, Dow Building Solutions R&D

Foam Vs Fiber. Air Sealing Benefit of Foam in Single Family Residential New Construction. Gary Parsons Fellow, Dow Building Solutions R&D Foam Vs Fiber Air Sealing Benefit of Foam in Single Family Residential New Construction Gary Parsons Fellow, Dow Building Solutions R&D Project TEETH A multi-home, 5 year research project, in partnership

More information

Detail Set: Thermax Wall System Masonry

Detail Set: Thermax Wall System Masonry Dow Building Solutions Detail Set: Thermax Wall System Masonry This detail set outlines the masonry guidelines for design using the THERMAX Wall System, focusing around attachment of masonry façades and

More information

Installation Procedures for the Ultra Air Barrier Wall System

Installation Procedures for the Ultra Air Barrier Wall System STEEL STUD BACKUP CONSTRUCTION Installation Procedures for the Ultra Air Barrier Wall System Installation Procedures for the Ultra Air Barrier Wall System in Steel Stud Backup 1 System Overview STYROFOAM

More information

Short Form Guide Specification. STYROFOAM CAVITYMATE Ultra Air Barrier Wall System

Short Form Guide Specification. STYROFOAM CAVITYMATE Ultra Air Barrier Wall System Short Form Guide Specification STYROFOAM CAVITYMATE Ultra Air Barrier Wall System November 2011 DISCLAIMER: The manufacturer has reviewed the product information contained in this short form specification.

More information

TECH SOLUTIONS LEED for Homes: Achieving. Points With Dow Building Solutions Products

TECH SOLUTIONS LEED for Homes: Achieving. Points With Dow Building Solutions Products Points With Dow Building Solutions Products Summary This document provides general information about LEED for Homes, a rating system developed by the U.S. Green Building Council (USGBC) that was officially

More information

Above Grade Wall Systems by Dow

Above Grade Wall Systems by Dow Dow Building Solutions Above Grade Wall Systems by Dow United States RESIDENTIAL Demand for High Quality Insulation Energy Efficiency: A Top Priority Second only to the mortgage, a family s home heating

More information

Improve Energy Efficiency and Air Sealing in Above-Grade Walls

Improve Energy Efficiency and Air Sealing in Above-Grade Walls Improve Energy Efficiency and Air Sealing in Above-Grade Walls United States. Residential Energy Efficiency Ranks Highest Second only to the mortgage, a family s home heating and cooling payments represent

More information

United States R E S I D E N T I A L. The Value of Residing With STYROFOAM Brand XPS Insulation

United States R E S I D E N T I A L. The Value of Residing With STYROFOAM Brand XPS Insulation United States R E S I D E N T I A L The Value of Residing With STYROFOAM Brand XPS Insulation 2 resists moisture Residing is a great opportunity to increase a home s value with a fresh, new look. It s

More information

STYROFOAM BRAND ULTRA SL Air Barrier Wall System w/ Flashing Tape Installation of Rigid Foam on CMU Backup

STYROFOAM BRAND ULTRA SL Air Barrier Wall System w/ Flashing Tape Installation of Rigid Foam on CMU Backup 0721 0 Short Form Guide Specification STYROFOAM BRAND ULTRA SL Air Barrier Wall System w/ Flashing Tape Installation of Rigid Foam on CMU Backup May 2013 0721 0 STYROFOAM Brand Ultra SL- Air Barrier-CMU

More information

Improve Energy Efficiency and Moisture Performance of Foundations

Improve Energy Efficiency and Moisture Performance of Foundations Improve Energy Efficiency and Moisture Performance of Foundations United States. Residential Build Value and Performance into Your Home Homes have one thing in common: Their foundations must come in contact

More information

TECH SOLUTIONS Hot Box Testing of Four Different Metal Building Roof Assemblies Determines Insulation Efficiency

TECH SOLUTIONS Hot Box Testing of Four Different Metal Building Roof Assemblies Determines Insulation Efficiency Summary Using the ASTM 1363, or hot box test, four different metal roofing assemblies were tested to determine their effective R-value versus the design R-value of the insulation. The ratio of these two

More information

an extensive line of science-based solutions residential. united states

an extensive line of science-based solutions residential. united states www.insulateyourhome.com www.dowsis.com an extensive line of science-based solutions residential. united states For more than 60 years, The Dow Chemical Company has been a recognized leader in extruded

More information

Guide Specification for the OSI QUAD Window and Door Flashing System

Guide Specification for the OSI QUAD Window and Door Flashing System Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification

More information

For GREAT STUFF PRO Window & Door Insulating Foam Sealant

For GREAT STUFF PRO Window & Door Insulating Foam Sealant United States/Canada R E S I D E N T I A L An Airtight Case For GREAT STUFF PRO Foam Sealant Air infiltration is a big waste of energy. And with heating and cooling costs skyrocketing, it can be a big

More information

Product and System Specifications DuPont Flashing Systems

Product and System Specifications DuPont Flashing Systems DuPont Building Innovations March 2007 4417 Lancaster Pike Chestnut Run Plaza 721 Wilmington, DE 19805 1-800-448-9835 www.construction.tyvek.com Product and System Specifications DuPont Flashing Systems

More information

Dow Building Solutions. Below Grade Systems by Dow

Dow Building Solutions. Below Grade Systems by Dow Dow Building Solutions Below Grade Systems by Dow United States/Canada RESIDENTIAL Build Value and Performance Into Your Home Homes have one thing in common: Their foundations must come in contact with

More information

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage

More information

Increase Energy Efficiency With STYROFOAM Brand CAVITYMATE Products

Increase Energy Efficiency With STYROFOAM Brand CAVITYMATE Products Dow Building Solutions Increase Energy Efficiency With CAVITYMATE Products United States COMMERCIAL Stack up the Benefits You and your customers will appreciate the many benefits of STYROFOAM Brand CAVITYMATE

More information

Improve Energy Efficiency and Moisture Performance of Foundations

Improve Energy Efficiency and Moisture Performance of Foundations Escalating home energy costs and changing energy codes are two big challenges facing builders today. Dow Building Solutions can help you meet those challenges and differentiate your business by building

More information

DuPont Flashing Systems Commercial Installation Guidelines

DuPont Flashing Systems Commercial Installation Guidelines DuPont DuPont Flashing Systems Commercial Installation Guidelines FOR STOREFRONT WINDOW ON SLAB AFTER WRB IS INSTALLED Table of Contents Applicable Products... 2 Recommended Materials... 2 Optional Materials...

More information

Figure 1 Brick & Block Cavity Wall

Figure 1 Brick & Block Cavity Wall Introduction The Wall System is a method to install rigid, STYROFOAM Brand CAVITYMATE Ultra extruded polystyrene insulation boards in a manner which achieves air/vapor barrier properties in addition to

More information

Reduce Wall Condensation Potential with Insulated Sheathing TECH SOLUTIONS 214.0

Reduce Wall Condensation Potential with Insulated Sheathing TECH SOLUTIONS 214.0 TECH SOLUTIONS 14. Reduce Wall Condensation Potential with Summary Insulated sheathing provides exceptional moisture protection performance in residential walls versus traditional spun-bonded polyolefin

More information

TECH SOLUTIONS Reduce Wall Condensation Potential with Insulated Sheathing

TECH SOLUTIONS Reduce Wall Condensation Potential with Insulated Sheathing TECH SOLUTIONS 14. Reduce Wall Condensation Potential with Summary Insulated sheathing provides exceptional moisture protection performance in residential walls versus traditional spun-bonded polyolefin

More information

SRP-AirOutshield UV Issued:

SRP-AirOutshield UV Issued: SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing

More information

DuPont Flashing Systems Commercial Installation Guidelines

DuPont Flashing Systems Commercial Installation Guidelines DuPont DuPont Flashing Systems Commercial Installation Guidelines FOR DUPONT THRU-WALL FLASHING SHELF ANGLE Table of Contents Applicable Products... 2 Required Materials... 2 Optional Materials... 3 DuPont

More information

DOWSIL Silicone Transition System: Application Guide Build a Better Barrier

DOWSIL Silicone Transition System: Application Guide Build a Better Barrier High Performance Building Consumer Solutions DOWSIL Silicone Transition System: Application Guide Build a Better Barrier DOWSIL Silicone Transition System Application Guide The DOWSIL Silicone Transition

More information

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2 DuPont Tyvek Air Barrier Installation Guidelines Helping you get the job done right Canadian Version Version 2 Table of Contents Applicable Products...2 Required Materials...2 Code Requirements...3 General

More information

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION SECTION 072700 VAPOR PERMEABLE AIR BARRIER LIQUID MEMBRANE PART 1 GENERAL 1.1 GENERAL REQUIREMENTS A. The Work of this Section, as shown or specified, shall be in accordance with the requirements of the

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.

More information

Perm-A-Barrier NPS (Non Permeable Sheet)

Perm-A-Barrier NPS (Non Permeable Sheet) NPS (Non Permeable Sheet) Primer-less self-adhered air & vapor barrier membrane Product Description NPS Wall Membranes are ideal for protecting the building superstructure from the damaging effects of

More information

United States SELECTOR GUIDE. Residing products

United States SELECTOR GUIDE. Residing products United States R E S I D E N T I A L SELECTOR GUIDE Residing products THE RIGHT PRODUCTS. Based on Building Science. Nearly 60 years ago, Dow pioneered rigid foam insulation with the introduction of STYROFOAM

More information

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane PERM-A-BARRIER VPS Self-adhering vapor permeable air and water barrier membrane Product Description GCP Applied Technologies ( GCP ) PERM-A-BARRIER VPS (Vapor Permeable Sheet) membrane is a vapor permeable

More information

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT SECTION 07 30 05.01 SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT SPEC WRITERS NOTE: This specification includes materials and installation procedures for SlopeShield SA Self-Adhered Water-Resistive Vapor

More information

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 2

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 2 The International Energy Conservation Code (IECC) contains energy-efficiency criteria for new construction, but keeping up with changes to the Code can be challenging. This document highlights the 2009

More information

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 3

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 3 Quick Reference Guide for 2009 IECC Residential Energy Efficiency The International Energy Conservation Code (IECC) contains energy-efficiency criteria for new construction, but keeping up with changes

More information

THERMAL AND AIR BARRIER WALL SYSTEM

THERMAL AND AIR BARRIER WALL SYSTEM 07 42 65 Short Form Guide Specification THERMAL AND AIR BARRIER WALL SYSTEM 07 42 65-1 SECTION 07 42 65 PART 1 - GENERAL 1.1 SUMMARY A. Provide a thermal and air barrier wall system for exterior cold-formed

More information

United States STYROFOAM DECKMATE PLUS INSULATION. Stands Up Under Standing Seam Metal Roofs

United States STYROFOAM DECKMATE PLUS INSULATION. Stands Up Under Standing Seam Metal Roofs United States C O M M E R C I A L STYROFOAM DECKMATE PLUS INSULATION Stands Up Under Standing Seam Metal Roofs A Lasting Choice For long-term durability and low maintenance, many building owners and designers

More information

Ultra Wall System. CAD Detail Sets

Ultra Wall System. CAD Detail Sets Ultra Wall System CAD Detail Sets Contents Page UWS-CM CAVITYMATE Ultra Contents 1-0 FOR: Details continuing on 1-1 thru 1-17 Cavity cut XPS board to fit between ladder tie masonry ties in CMU walls UWS-SL

More information

WeatherSmart Air Barrier Installation Guide

WeatherSmart Air Barrier Installation Guide WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material

More information

Perm-A-Barrier VPS (Vapor Permeable Sheet)

Perm-A-Barrier VPS (Vapor Permeable Sheet) VPS (Vapor Permeable Sheet) Self-adhering vapor permeable air barrier membrane Product Description VPS (Vapor Permeable Sheet) is a vapor permeable air barrier membrane consisting of a proprietary breathable

More information

Container Installation Guide

Container Installation Guide Container Insulation Container Installation Guide Panels and Inserts The InSoFast CX Container panel and the Inserts are designed to fit most shipping containers. Containers have three types of corrugations:

More information

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 6

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 6 Quick Reference Guide for 2009 IECC Residential Energy Efficiency The International Energy Conservation Code (IECC) contains energy-efficiency criteria for new construction, but keeping up with changes

More information

Reduce Wall Condensation Potential with Insulated Sheathing TECH SOLUTIONS 214.0

Reduce Wall Condensation Potential with Insulated Sheathing TECH SOLUTIONS 214.0 Reduce Wall Condensation Potential with Summary Insulated sheathing provides exceptional moisture protection performance in residential walls versus traditional spun-bonded polyolefin housewrap with oriented

More information

A. Source Limitations: Obtain each type of building insulation through one source.

A. Source Limitations: Obtain each type of building insulation through one source. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Container Installation Guide

Container Installation Guide Continuous Insulation Container Installation Guide Panels and InSerts The InSoFast CX Container panel and the InSerts are designed to fit most shipping containers. Containers have three types of corrugations:

More information

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812

More information

Improve Energy Efficiency and Air Sealing in Above-Grade Walls

Improve Energy Efficiency and Air Sealing in Above-Grade Walls Improve Energy Efficiency and Air Sealing in Above-Grade Walls United States. Residential Energy Efficiency Ranks Highest Second only to the mortgage, a family s home heating and cooling payments represent

More information

Air and Vapor Barrier 3015

Air and Vapor Barrier 3015 Air and Vapor Barrier 3015 Technical Data March 2017 Product Description 3M Air and Vapor Barrier 3015 is an air, moisture and water impermeable membrane with an aggressive, high-tack acrylic pressure

More information

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS SECTION 072800 FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS This section includes editing notes to assist the user in editing the section to suit project requirements. These notes are

More information

SECTION FOIL FACED POLYISOCYANURATE FOAM BOARD INSULATION. A. Rigid polyisocyanurate foam board insulation with aluminum facers.

SECTION FOIL FACED POLYISOCYANURATE FOAM BOARD INSULATION. A. Rigid polyisocyanurate foam board insulation with aluminum facers. The following information has been compiled in accordance with the Construction Specifications Institute (CSI) MasterFormat to enhance Atlas EnergyShield Polyiso Continuous Wall Insulation project specifications.

More information

(Project Location) (your firm's name)

(Project Location) (your firm's name) SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections

More information

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812

More information

United States SELECTOR GUIDE. Metal building products

United States SELECTOR GUIDE. Metal building products United States C O M M E R C I A L SELECTOR GUIDE Metal building products THE RIGHT SOURCE. The Right Solutions. For 60 years, The Dow Chemical Company has been a recognized leader in extruded polystyrene

More information

Building Envelope Solutions, Inc. Identifying solutions for better building performance

Building Envelope Solutions, Inc. Identifying solutions for better building performance Building Envelope Solutions, Inc. Identifying solutions for better building performance SUPERGREEN LAM TM (Liquid-applied Membrane) Background of the development of SUPERGREEN LAM TM : Spray-applied polyurethane

More information

SECTION SELF-ADHERING SHEET FLASHING

SECTION SELF-ADHERING SHEET FLASHING MANUFACTURER S GUIDE SPECIFICATIONS SECTION 076526 SELF-ADHERING SHEET FLASHING 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 604129 03.24.15 Carlisle, Flexphalt, Sure-Seal and CAV-GRIP

More information

Installation Guide Sto RapidGuard

Installation Guide Sto RapidGuard ATTENTION Sto products are intended for use by qualified professional contractors, not consumers, as a component of a larger construction assembly as specified by a qualified design professional, general

More information

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas. SPECIFICATION FOR PROTECTO WRAP AFM-WM FOR INTERNAL WET AREAS BRANZ Appraisal Certificate # 461 (2010) Internal wet areas AFM/WM INTERNAL 0104 Page 1 AFM-WM INTERNAL SPECIFICATION PRODUCT DESCRIPTION Anti

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 071326 - SELF-ADHERING SHEET WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4 The International Energy Conservation Code (IECC) contains energy-efficiency criteria for new construction, but keeping up with changes to the Code can be challenging. This document highlights the 2009

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: HCI System RAINSCREEN ATTACHEMNT HORIZONTAL ORIENTED GIRT VERTICAL PanelRail & RevealRail SYSTEM DEPTH: 1.5 INCHES (FACE OF RIGID INSULATION TO FACE OF RAIL) QUICK LINK:

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: MFI System - S-Series (HORIZONTAL) for CLADDING PANELS HORIZONTAL ORIENTED SYSTEM WITH OPTIONAL VERTICAL PanelRails (EXTERIOR INSULATION OMITTED FOR CLARITY) MINIMUM

More information

PART 4 - SELF ADHERING WATERPROOFING

PART 4 - SELF ADHERING WATERPROOFING Part 1 - General 1.1 General.1 Related Documents: Provisions established within General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and the Drawings are collectively

More information

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate Colphene BSW Training and Application Guide Colphene BSW Waterproofing Membrane. 1. Prepare substrate Substrate must be structurally sound. Surface must be free of voids, spalled areas, loose aggregate,

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet Perimeter Installation Procedures Concrete Faced Insulated Perimeter Wall Panels Concrete Faced Insulated Perimeter Wall Panels are prefinished, one-step exterior insulating panels

More information

Henry Blueskin VP160 Air Barrier System Installation Manual

Henry Blueskin VP160 Air Barrier System Installation Manual Henry Blueskin VP160 Air Barrier System Installation Manual Building Envelope Systems 1 Effective 09/28/2017 US Supersedes all previous versions Table of contents 1. Introduction...3 1.01 Air barrier considerations...3

More information

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS Stucco Flange (Jump Frame) Install Although all possible measures have been taken to insure the accuracy of the material presented, WIXSYS, and

More information

SECTION TW-60 Self-Adhering Sheet Waterproofing Membrane

SECTION TW-60 Self-Adhering Sheet Waterproofing Membrane This three-part specification is for design professionals for use as a guide and must be edited to delete information and instructions not required on a particular project. Delete the specifier notes in

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: HCI System (HORIZONTAL HCI-Girt ) for CLADDING PANELS HORIZONTAL ORIENTED GIRT ONLY SYSTEM DEPTH: 0.75 INCHES (FACE OF RIGID INSULATION TO FACE OF RAIL) QUICK LINK: SECTION

More information

RECOMMENDED DESIGN SPECIFICATION

RECOMMENDED DESIGN SPECIFICATION RECOMMENDED DESIGN SPECIFICATION SILICONE COATED SPF ROOFING 1 General 1.1 Section Includes A. Silicone coated SPF roofing system, including substrate board, roof insulation boards, foam insulation materials,

More information

Construction Standards PAGE

Construction Standards PAGE Construction Standards PAGE 072100-1 SECTION 072100 PART 1 - GENERAL 1.1 M.S.U. ISSUES A. It the intent of MSU that insulation of its projects will comply with LEED NC 3 Credit Requirements EA Prerequisite

More information

Short Form Guide Specification. THERMAL, WATER, AND AIR BARRIER WALL ASSEMBLY [Public Bid]

Short Form Guide Specification. THERMAL, WATER, AND AIR BARRIER WALL ASSEMBLY [Public Bid] 07 21 66 Short Form Guide Specification THERMAL, WATER, AND AIR BARRIER WALL ASSEMBLY [Public Bid] October 2016 PART 1 - GENERAL 1.1 SUMMARY A. SECTION INCLUDES- Contractors choice of one of the following

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

application instructions

application instructions application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds

More information

Single Component 100% Silicone Sealant INSTALLATION INSTRUCTIONS

Single Component 100% Silicone Sealant INSTALLATION INSTRUCTIONS OVERVIEW VaproBond is a single component 100% silicone sealant designed to function as an adhesive sealant and an allweather silicone liquid flashing material. APPLICATION VaproBond is appropriate for

More information

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS VAPROLIQUI-FLASH Liquid Applied Waterproof Flashing Material OVERVIEW VaproLiqui-Flash is a liquid applied Waterproof Flashing material for window and door rough opening interfaces. It is designed for

More information

Wabo FireShield Model: FSH

Wabo FireShield Model: FSH Wabo FireShield Model: FSH Horizontal Expansion Control Fire Barrier System The following installation procedure is very important and must be fully understood prior to beginning any work. To ensure proper

More information

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3914 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00

More information

1 of 17. PO Box Bellevue Rd, Newark, DE V F

1 of 17. PO Box Bellevue Rd, Newark, DE V F 1 of 17 Raw Material Manufactured from 4 8-foot sheets Fiber-reinforced 1-mil aluminumfaced polyisocyanurate panels 0.032 embossed aluminum Other patterns and stainless steel are available Necessary supplies

More information

for New Construction Applications

for New Construction Applications INSTALLATION GUIDE for New Construction Applications Designing and building instructions for ThermalStar LCi are described in the following manual. General installation, fastening details and instructions

More information

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS Face Seal Fin and Integral J-Channel Install Although all possible measures have been taken to insure the accuracy of the material presented, WIXSYS,

More information

KNIGHT WALL SYSTEMS GUIDE DETAILS:

KNIGHT WALL SYSTEMS GUIDE DETAILS: KNIGHT WALL SYSTEMS GUIDE DETAILS: MFI System - S-Series (VERTICAL) for CLADDING PANELS VERTICAL ORIENTED SYSTEM WITH OPTIONAL HORIZONTAL PanelRails (EXTERIOR INSULATION OMITTED FOR CLARITY) MINIMUM DEPTH:

More information

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation

EPA Seal and Insulate with ENERGY STAR Insulation Product Certification Report: GAF EnergyGuard Polyiso Insulated Sheathing Board Insulation UL LLC 333 Pfingsten Road Northbrook, IL 60062 2017-6-05 U.S. Environmental Protection Agency (EPA) Seal and Insulate with ENERGY STAR Insulation Product Certification Report Type EnergyGuard Polyiso Insulated

More information

BITUTHENE Deck System

BITUTHENE Deck System BITUTHENE Deck System Cold-applied, waterproofing system for inverted roofs, green roofs and elevated decks Product Description BITUTHENE Deck System combines BITUTHENE 4000 sheet membranes with BITUTHENE

More information

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION CSI FORMAT SECTION PART 1 - GENERAL 1.1 SUMMARY A. Provide foil-faced thermal insulation in exterior wall assemblies, to function as a thermal, moisture, and air barrier wall system. 1.2 RELATED WORK A.

More information

PERM-A-BARRIER NPS Detail Membrane

PERM-A-BARRIER NPS Detail Membrane PERM-A-BARRIER NPS Detail Membrane Primerless self-adhered detail membrane for air and vapor barrier applications Product Description GCP Applied Technologies ( GCP ) PERM-A-BARRIER NPS Detail Membrane

More information

ITEM 458 WATERPROOFING FOR STRUCTURES

ITEM 458 WATERPROOFING FOR STRUCTURES ITEM 458 WATERPROOFING FOR STRUCTURES 458.1. Description. This Item shall govern for the furnishing and placing of waterproofing on concrete and steel bridge decks of railroad structures and on other structures

More information

ZIP System Liquid Flash

ZIP System Liquid Flash 2012 Huber Engineered Woods LLC. ZIP System and the accompanying ZIP System logo and design, are trademarks of Huber Engineered Woods LLC. Huber is a registered trademark of J.M. Huber Corporation. Patents

More information

Dow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green

Dow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green Silicone Air Barrier System of shade energy-efficient A more green Air and Moisture Protection for More Energy-Efficient Buildings Meeting regulatory requirements for energy efficiency is a significant

More information

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS Replace Window with Patio Door Although all possible measures have been taken to insure the accuracy of the material presented, WIXSYS, and the

More information

INSTALLATION GUIDE EPS FOAM

INSTALLATION GUIDE EPS FOAM INSTALLATION GUIDE EPS FOAM EPS Foam: Multipurpose rigid foam boards can be used for a variety of applications including insulation in walls, roofs, and foundations, for retrofits or new construction.

More information

Flashing Installation Guidelines Using DuPont Tyvek Fluid Applied Flashing-Brush Formulation

Flashing Installation Guidelines Using DuPont Tyvek Fluid Applied Flashing-Brush Formulation StraightFlash VF StraightFlash Tyvek Fluid pplied Flashing rush Formulation Flashing Installation Guidelines Using Tyvek Fluid pplied Flashing-rush Formulation Integral Flanged Window In Recessed Opening

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu INSTALLATION INSTRUCTIONS Note: The following installation instructions are based off of ASTM E 1643 (Standard Practice for Installation of Water Vapor Retarders Used in Contact with Earth or Granular

More information

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL

More information

PART 2 - AIR BARRIERS SELF-ADHESIVE

PART 2 - AIR BARRIERS SELF-ADHESIVE Part 1 - General 1.1 General.1 Related Documents: Provisions established within General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and the Drawings are collectively

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3089 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00

More information