The 2010 Revision to the ASTM B 813 Standard

Size: px
Start display at page:

Download "The 2010 Revision to the ASTM B 813 Standard"

Transcription

1 The 20 Revision to the ASTM B 813 Standard

2 ASTM B 813- Plumbing or Mechanical systems are only as strong as the weakest joint

3 ASTM B 813- The revisions to the ASTM B813 Standard are in General Requirements Section 3 as follows:

4 ASTM B 813- Section General Requirements The flux residue shall be water flushable after soldering as specified in accordance with Section 7 and 9.

5 ASTM B 813- Section 3.6 The flux residue shall not be corrosive or toxic after soldering potable water systems.

6 ASTM B 813- Section 3.7 The flux shall not release toxic fumes during the soldering operation or corrosive or toxic substances into the water inside or outside the completed system.

7 ASTM B 813- Reprinted, with permission, from ASTM B813- Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube, copyright ASTM International (ASTM), 0 Barr Harbor Drive, West Conshohocken, PA A copy of the complete standard may be obtained from ASTM, Link to ASTM:

8 ASTM B 813- Code enforcement officials require updated ASTM standards information referenced in the Plumbing/Mechanical codes The Active current ASTM standards are referenced by Code Officials & users of Codes and Standards Distributors are required to sell products compliant with state laws and current standards: California: AB1953 Vermont: S.152

9 ASTM B 813- Liability increases significantly with non-compliant products Manufacturers of listed products will provide a copy of their listing from the listing agency. Listing Agencies also provide copies of their listings on their websites or their book publications.

10 ASTM B 813- Contractors/Installers are required to install products compliant with current Plumbing/Heating/Mechanical codes and referenced standards

11 ASTM B 813- The goal of Plumbing Codes and Standards regarding products and installation remains constant: Protect the Public Health and Potable water supply, providing specifications and pass/fail requirements.

12 The revisions to ASTM B813 will impact: potable water quality & purity (no corrosive & toxic residues) reduction of health hazard to the plumber/pipefitter environmental quality workmanship & system longevity how products are manufactured, specified & distributed

13 FAQ s What is the relevant State Code? CA: California State Plumbing Code 2007 (UPC w/ amendments) HI: Hawaii State Plumbing Code (2006 UPC w/amendments) WA: Washington Plumbing Code 2009 (UPC w/ amendments)

14 FAQ s What is the relevant State Code? OR: Oregon Plumbing Specialty Code (based on the UPC w/ amendments) AK: Alaska State Plumbing Code (2006 UPC w/ amendments) NY: New York State Plumbing Code 2007 (based on the 2003 IPC w/ny modifications) *Exception: Detached one and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories in height above grade with separate means of egress and their accessory structures shall comply with the Residential Code of New York State. TX: Texas uses either the UPC the IPC with amendments (2000,2003,2006, 2009 versions depending on the jurisdiction)

15 FAQ s Where do I find the Plumbing Code requirements for paste flux used in soldered joints? In the UPC 2009: Administration: 1.2, 1.4.3, 1.5.2, Definitions: 207.0, General Regulations: , Water Heaters: (2) (a) Water Supply & Distribution: 602.1, , , *** Soldered Joints (20 preprint) Mandatory Referenced Standards: 14-1

16 FAQ s IPC 2009 Scope and Administration: 1.2, 2.1 General Regulations: 301.7, 303.2, Water Supply and Distribution: , Sanitary Drainage: ,

17 FAQ s 2007 California Plumbing Code: see matrix for specific agency General Code Provisions: : 1.3.1, 1.3.2, 1.5, Definitions: approved, General Provisions: Water Heaters: Water Supply & Distribution: 602.1, , 604.1, Mandatory Referenced Standards: 14-1

18 FAQ s 2007 New York State Plumbing Code (IPC-modified) General Requirements: 2.4 Chapter 3 General Regulations: Materials: 303.2, 303.4, Water supply & Distribution: , Sanitary Drainage: , Referenced Standards List: Chapter 13

19 FAQ s What determines Code compliance? Compliance means product has 3 rd party certification to referenced mandatory standards which are included in the respective code.

20 FAQ s Are Listing Agency logos on the products? Yes, listing agency logos are on compliant products. Listings are also published on the Websites of listing organizations: ASTM, NSF, IAPMO, ICC, UL,, LADBS etc.

21 ASTM B 813- What is governing authority if a Code and a Standard conflict? Code is the governing authority

22 ASTM B 813- International Residential Code is also used by many jurisdictions. Sections R2.1 General. Where there is a conflict between a general eral requirement and a specific requirement, the specific requirement shall be applicable. Where, in any specific case, different sections of this code specify different materials, methods of construction n or other requirements, the most restrictive shall govern. Section R 2 Applicability R2.4 Referenced codes and standards. The codes and standards referenced in this code shall be considered part of the requirements ents of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply. Exception: Where enforcement of a code provision would violate v the conditions of the listing of the equipment or appliance, the conditions of the listing and manufacturer s s instructions shall apply.

23 ASTM B 813- UPC Chapter 3 General Regulations Standards Standards listed or referred to in this chapter or other chapters cover materials that will conform to the requirements of this code, when used in accordance with the limitations imposed in this or other chapters thereof and their listing.

24 ASTM B 813- NYS Plumbing Code Chapter 1 General Requirements 2.1 General. Where, in any specific case, different sections of this code specify different, materials, methods of construction or other requirements, the most restrictive shall be applicable. Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable.

25 ASTM B 813- Plumbing or Mechanical systems are only as strong as the weakest joint

26 ASTM B 813- Corrosive residue is toxic and prohibited inside and outside completed potable water systems. Corroded joints lead to premature system failure.

27 Acronyms: IAPMO: INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UPC: UNIFORM PLUMBING CODE produced by IAPMO UMC: UNIFORM MECHANICAL CODE produced by IAPMO ICC: INTERNATIONAL CODE COUNCIL IPC: INTERNATIONAL PLUMBING CODE produced by ICC IRC: INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO FAMILY DWELLINGS produced by ICC

28 Summary of Changes to ASTM B813- Section 3.5 The flux residue shall be water flushable after soldering as specified in accordance with Section 7 and 9. Section 3.6 The flux residue shall not be corrosive or toxic after soldering potable water systems. Section 3.7 The flux shall not release toxic fumes during the soldering operation or corrosive or toxic substances into the water inside or outside e the completed system.

29 Complies with ASTM B 813- Standard Water Flushable after soldering Lead free & Environmentally safe Does not leave corrosive or toxic residue after soldering No toxic fumes while soldering No zinc or ammonium chlorides (extremely corrosive) No petrolatum (i.e. Vaseline) Will not freeze or separate and does not absorb water Will not contaminate Freon or glycol systems Does not pop when soldering Works on wet pipes Does not burn on skin or in open wounds Does not turn hands black or green Solder up to 4 4 pipe without burning away Easy and economical to use

30

2015 IBC Chapters 1 and 35

2015 IBC Chapters 1 and 35 Study Session 1 2015 IBC Chapters 1 and 35 Administration OBJECTIVE: To obtain an understanding of the administrative provisions of the International Building Code Ò (IBC Ò ), including the scope and purpose

More information

Lead Free January 4, 2014

Lead Free January 4, 2014 Lead Free January 4, 2014 General FAQs What is the Reduction of Lead in Drinking Water Act? The Reduction of Lead in Drinking Water Act is a federal law that amends the Safe Drinking Water Act (SDWA) and

More information

IRC Fire Protection of Floors Code Language 2012 IRC R IRC R302.13

IRC Fire Protection of Floors Code Language 2012 IRC R IRC R302.13 IRC Fire Protection of Floors Code Language 2012 IRC R501.3 2015 IRC R302.13 Current IRC Code Adopted into Some State Laws R501.3 Fire Protection of Floors Floor assemblies, not required elsewhere in this

More information

EVALUATION SUBJECT: VIEGA LLC S PUREFLOW PLUMBING SYSTEM

EVALUATION SUBJECT: VIEGA LLC S PUREFLOW PLUMBING SYSTEM ICC-ES Report PMG-1038 Reissued 11/2018 This report is subject to renewal 11/2019 EVALUATION SUBJECT: VIEGA LLC S PUREFLOW PLUMBING SYSTEM DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING

More information

EVALUATION SUBJECT: TEEL BQ POLYPROPYLENE (PP-RCT) PIPING SYSTEM

EVALUATION SUBJECT: TEEL BQ POLYPROPYLENE (PP-RCT) PIPING SYSTEM ICC-ES Report PMG-1452 Issued 01/2018 This report is subject to renewal 01/2019 EVALUATION SUBJECT: TEEL BQ POLYPROPYLENE (PP-RCT) PIPING SYSTEM DIVISION: 22 00 00 PLUMBING SECTION: 22 11 00 FACILITY WATER

More information

PMG LISTING CRITERIA FOR PUSH-FIT FITTINGS FOR POTABLE WATER TUBE AND RADIANT HEATING SYSTEMS LC1009

PMG LISTING CRITERIA FOR PUSH-FIT FITTINGS FOR POTABLE WATER TUBE AND RADIANT HEATING SYSTEMS LC1009 www.icc-es.org/pmg (800) 42-6587 (562) 699-054 A Subsidiary of the International Code Council PMG LISTING CRITERIA FOR PUSH-FIT FITTINGS FOR POTABLE WATER TUBE AND RADIANT HEATING SYSTEMS Approved April

More information

PMG LISTING CRITERIA FOR PRESS-CONNECTION FITTINGS FOR POTABLE WATER TUBE AND RADIANT HEATING SYSTEMS PREFACE

PMG LISTING CRITERIA FOR PRESS-CONNECTION FITTINGS FOR POTABLE WATER TUBE AND RADIANT HEATING SYSTEMS PREFACE Title???? Page 1 of 1 www.icc-es.org/pmg (800) 42-6587 (562) 699-054 A Subsidiary of the International Code Council PMG LISTING CRITERIA FOR PRESS-CONNECTION FITTINGS FOR POTABLE WATER TUBE AND RADIANT

More information

Calculation of Heater-tube Thickness in Petroleum Refineries API STANDARD 530 SEVENTH EDITION, APRIL 2015

Calculation of Heater-tube Thickness in Petroleum Refineries API STANDARD 530 SEVENTH EDITION, APRIL 2015 Calculation of Heater-tube Thickness in Petroleum Refineries API STANDARD 530 SEVENTH EDITION, APRIL 2015 Special Notes API publications necessarily address problems of a general nature. With respect to

More information

PMG LISTING CRITERIA FOR PERT-AL-PERT PIPE AND FITTINGS FOR REFRIGERATION APPLICATIONS LC1039. Approved Date: November 2015 PREFACE

PMG LISTING CRITERIA FOR PERT-AL-PERT PIPE AND FITTINGS FOR REFRIGERATION APPLICATIONS LC1039. Approved Date: November 2015 PREFACE www.icc-es.org/pmg (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council PMG LISTING CRITERIA FOR PERT-AL-PERT PIPE AND FITTINGS FOR REFRIGERATION APPLICATIONS Approved Date: November

More information

A BILL FOR AN ORDINANCE

A BILL FOR AN ORDINANCE A BILL FOR AN ORDINANCE ORDINANCE NO: 23 SERIES OF 2013 INTRODUCED BY: COUNCILMEMBER ROEMER AN ORDINANCE REPEALING AND REENACTING ARTICLES 2 THROUGH 8 OF CHAPTER 18 OF THE GREENWOOD VILLAGE CODE TO ADOPT

More information

SOUTHERN NEVADA AMENDMENTS TO THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE

SOUTHERN NEVADA AMENDMENTS TO THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE SOUTHERN NEVADA AMENDMENTS TO THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE PREFACE This document was developed by the Southern Nevada Building Officials International Energy Conservation Code Committee

More information

EVALUATION SUBJECT: AQUATECHNIK SAFETY -POL PEX- AL-PEX PIPE AND FITTING SYSTEM

EVALUATION SUBJECT: AQUATECHNIK SAFETY -POL PEX- AL-PEX PIPE AND FITTING SYSTEM ICC-ES Report PMG-1437 Reissued 08/2018 This report is subject to renewal 08/2019 EVALUATION SUBJECT: AQUATECHNIK SAFETY -POL PEX- AL-PEX PIPE AND FITTING SYSTEM DIVISION: 23 00 00 HEATING, VENTILATING

More information

NEW 2007 CALIFORNIA BUILDING STANDARDS CODE

NEW 2007 CALIFORNIA BUILDING STANDARDS CODE IMPORTANT NOTICE REGARDING THE NEW 2007 CALIFORNIA BUILDING STANDARDS CODE Effective January 1, 2008, a new 2007 California Building Standards Code will take effect. The 2007 California Building Standards

More information

Narrative Summary of Changes to PA UCC

Narrative Summary of Changes to PA UCC Narrative Summary of Changes to PA UCC 401.1. Definitions. This section changes the definitions for the IBC, the IECC, the IEBC, the IFC, the IFGC, the IMC, the International Performance Code, the IPC,

More information

EVALUATION SUBJECT: NIRON POLYPROPYLENE (PP-RCT) PIPING SYSTEM DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING

EVALUATION SUBJECT: NIRON POLYPROPYLENE (PP-RCT) PIPING SYSTEM DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING ICC-ES Report PMG-1244 Reissued 04/2017 This report is subject to renewal 04/2018 EVALUATION SUBJECT: NIRON POLYPROPYLENE (PP-RCT) PIPING SYSTEM DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER

More information

TITLE 15: BUILDINGS AND CONSTRUCTION GENERAL PROVISIONS

TITLE 15: BUILDINGS AND CONSTRUCTION GENERAL PROVISIONS TITLE 15: BUILDINGS AND CONSTRUCTION Chapter 15.01 GENERAL PROVISIONS 15.02. OREGON MECHANICAL SPECIALTY CODE ADOPTION 15.04. DANGEROUS BUILDINGS CODE 15.05. UNIFORM CODE FOR BUILDING CONSERVATION 15.06.

More information

2015 ISEP INTERNATIONAL SOLAR ENERGY PROVISIONS

2015 ISEP INTERNATIONAL SOLAR ENERGY PROVISIONS 2015 ISEP INTERNATIONAL SOLAR ENERGY PROVISIONS Includes all I-Code solar energy provisions, plus SRCC Standards 100, 300 and 600 CODE ALERT! Sign up now to receive critical code updates and free access

More information

Engineering Specifications

Engineering Specifications PROPRESS WITH SMART CONNECT FEATURE PART 1: GENERAL 1.1 SUMMARY A. Copper Tubing and Fitting System for Hot and Cold Water Distribution Systems, Sprinkler and Standpipe Systems and Hydronic Piping Systems

More information

Engineering Specifications

Engineering Specifications PROPRESS WITH SMART CONNECT FEATURE PART 1: GENERAL 1.1 SUMMARY A. Copper Tubing and Fitting System for Hot and Cold Water Distribution Systems, Sprinkler and Standpipe Systems and Hydronic Piping Systems

More information

EVALUATION SUBJECT: CURAFLO ENGINEERED FLOW LINING SYSTEMS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING.

EVALUATION SUBJECT: CURAFLO ENGINEERED FLOW LINING SYSTEMS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING. ICC-ES Report PMG-1057 Reissued 02/2018 This report is subject to renewal 02/2019 EVALUATION SUBJECT: CURAFLO ENGINEERED FLOW LINING SYSTEMS DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER

More information

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System ICC-SRCC LISTING SRCC TM Solar Heating & Cooling Code & Standard Listing Program Listing Number: SRCC-16004 Effective Date: May 27, 2017 This listing is subject to re-examination in one year. www.solar-rating.org

More information

2012 VIRGINIA INDUSTRIALIZED BUILDING SAFETY REGULATIONS

2012 VIRGINIA INDUSTRIALIZED BUILDING SAFETY REGULATIONS 13VAC5-91-10. Definitions. The following words and terms when used in this chapter shall have the following meanings unless the context clearly indicates otherwise. Administrator means the Director of

More information

CODE ACTION AMENDMENTS

CODE ACTION AMENDMENTS UCC Review and Advisory Council OFFICIAL Record of 2015 I-Code Review May 1, 2018 CODE ACTION AMENDMENTS 2015 ADMIN ADOPT None 2015 IWUIC ADOPT None 2015 IFC ADOPT None 2015 IBC ADOPT Delete Section 913.2.2

More information

Engineering Specifications

Engineering Specifications Zero Lead* ProPress Fitting System With Smart Connect Technology PART 1: GENERAL 1.1 SUMMARY A. Copper Tubing and Fitting System for Hot and Cold Water Distribution Systems, Sprinkler and Standpipe Systems

More information

PMG LISTING CRITERIA FOR MULTILAYER PIPE AND FITTINGS ASSEMBLY FOR REFRIGERANT APPLICATIONS LC1036

PMG LISTING CRITERIA FOR MULTILAYER PIPE AND FITTINGS ASSEMBLY FOR REFRIGERANT APPLICATIONS LC1036 www.icc-es-pmg.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council PMG LISTING CRITERIA FOR MULTILAYER PIPE AND FITTINGS ASSEMBLY FOR REFRIGERANT APPLICATIONS LC1036 August

More information

today!

today! Receive FREE updates, excerpts of code references, technical articles, and more when you register your code book. Go to www.iccsafe.org/codesplus today! 2009 International Property Maintenance Code First

More information

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE Chapter 23.12 UNIFORM CODES FOR CONSTRUCTION BUILDING CODE 23.12.010 Adoption of the 2010 California Building Code. Part 2. Title 24 of the California Code of Regulations. There is adopted and incorporated

More information

CERTIFICATIONS AND LISTINGS

CERTIFICATIONS AND LISTINGS CERTIFICATIONS AND LISTINGS REHAU PEXa Tubing, Effective October 2017 TABLE OF CONTENTS Table 1: REHAU Certifications and Listings 1. REHAU PEX Tubing..................................4 2. Fire-rated Assembly

More information

SOUTHERN NEVADA AMENDMENTS TO THE 2009 INTERNATIONAL RESIDENTIAL CODE

SOUTHERN NEVADA AMENDMENTS TO THE 2009 INTERNATIONAL RESIDENTIAL CODE SOUTHERN NEVADA AMENDMENTS TO THE 2009 INTERNATIONAL RESIDENTIAL CODE First Printing: December 17, 2010 Clark County Ronald L. Lynn 4701 W. Russell Road Las Vegas, Nevada 89118 (702) 455-3000 Inspections

More information

S-QC-009 REV.0 ASTM C

S-QC-009 REV.0 ASTM C S-QC-009 REV.0 ASTM C 117-03 Designation: C 117 03 Standard Test Method for Materials Finer than 75-µm (No. 200) Sieve in Mineral Aggregates by Washing 1 This standard is issued under the fixed designation

More information

UNIFORM CODE ADMINISTRATION AND ENFORCEMENT REPORT (REPORTING YEAR: 2018)

UNIFORM CODE ADMINISTRATION AND ENFORCEMENT REPORT (REPORTING YEAR: 2018) Instructions One Commerce Plaza 99 Washington Ave, Suite 116 Albany, NY 12231-1 (518) 474-473 Fax. (518) 474-5788 https://www.dos.ny.gov/dcea The official who oversees code enforcement activities for your

More information

A Member of the International Code Family INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE

A Member of the International Code Family INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE A Member of the International Code Family INTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE 2006 2006 International Private Sewage Disposal Code First Printing: January 2006 Second Printing: December 2006 Third

More information

Copper and Copper Alloy Press-Connect Pressure Fittings

Copper and Copper Alloy Press-Connect Pressure Fittings ASME B16.51-2013 (Revision of ASME B16.51-2011) Proposed Revision of: Copper and Copper Alloy Press-Connect Pressure Fittings Draft Date 06/2018 Seamless Copper Water Tube. The size designations of the

More information

2015 Proposed Residential Code with Amendments

2015 Proposed Residential Code with Amendments 2015 Proposed with Amendments A resolution of the recommending adoption the 2015 edition of the International, regulating and governing the construction, alteration, movement, enlargement, replacement,

More information

XI'AN LINKUN STEEL PIPE CO., LTD

XI'AN LINKUN STEEL PIPE CO., LTD Designation: A 50 0 (Reapproved 2005) Standard Specification for Hot-Formed Welded and Seamless Carbon Steel Structural Tubing This standard is issued under the fixed designation A 50; the number immediately

More information

Standard Specification for Copper-Base Alloy Centrifugal Castings 1

Standard Specification for Copper-Base Alloy Centrifugal Castings 1 Designation: B 271 06 Standard Specification for Copper-Base Alloy Centrifugal Castings 1 This standard is issued under the fixed designation B 271; the number immediately following the designation indicates

More information

Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service 1

Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service 1 Designation: A 269 04 Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service 1 This standard is issued under the fixed designation A 269; the number immediately

More information

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System ICC-SRCC LISTING ICC-SRCC Solar Thermal Listing Program Listing Number: SRCC-16004 Effective Date: May 31, 2018 This listing is subject to re-examination in one year. www.solar-rating.org (888) 422-7233

More information

EVALUATION SUBJECT: PERMA-LATERAL PULLED- IN-PLACE CURED-IN-PLACE PIPE LINING SYSTEM

EVALUATION SUBJECT: PERMA-LATERAL PULLED- IN-PLACE CURED-IN-PLACE PIPE LINING SYSTEM ICC-ES Report PMG-1074 Reissued 11/2017 This report is subject to renewal 11/2018 EVALUATION SUBJECT: PERMA-LATERAL PULLED- IN-PLACE CURED-IN-PLACE PIPE LINING SYSTEM DIVISION: 22 00 00 PLUMBING SECTION:

More information

PLEASE FOLLOW INSTRUCTIONS ON PAGE FIVE

PLEASE FOLLOW INSTRUCTIONS ON PAGE FIVE WASHINGTON STATE BUILDING CODE COUNCIL APPLICATION FOR REVIEW OF A PROPOSED STATEWIDE AMENDMENT TO THE WASHINGTON STATE BUILDING CODE 2012 Code Adoption Cycle Log # (office use only) PLEASE FOLLOW INSTRUCTIONS

More information

PMG LISTING CRITERIA FOR STRUCTURAL ADHESIVE JOINING SYSTEMS FOR FITTINGS PREFACE

PMG LISTING CRITERIA FOR STRUCTURAL ADHESIVE JOINING SYSTEMS FOR FITTINGS PREFACE www.icc-es.org/pmg (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council PMG LISTING CRITERIA FOR STRUCTURAL ADHESIVE JOINING SYSTEMS FOR FITTINGS Approved March 2009 (Editorially

More information

Code Changes Resource Collection: 2009 IPC

Code Changes Resource Collection: 2009 IPC Code Changes Resource Collection: 2009 IPC First Printing: March 2009 COPYRIGHT 8 2009 BY INTERNATIONAL CODE COUNCIL, INC. ALL RIGHTS RESERVED. This 2009 Code Changes Resource Collection: 2009 IPC is a

More information

Standard Practice for Sampling Bituminous Materials 1

Standard Practice for Sampling Bituminous Materials 1 Designation: D 140 01 Standard Practice for Sampling Bituminous Materials 1 This standard is issued under the fixed designation D 140; the number immediately following the designation indicates the year

More information

Amendments to the 2012 International Plumbing Code

Amendments to the 2012 International Plumbing Code Amendments to the 2012 International Plumbing Code The following sections, paragraphs, and sentences of the 2012 International Plumbing Code are hereby amended as follows: Standard type is text from the

More information

Standard Specification for Copper and Copper Alloy Forging Rod, Bar, and Shapes 1

Standard Specification for Copper and Copper Alloy Forging Rod, Bar, and Shapes 1 Designation: B 124/B 124M 06 Standard Specification for Copper and Copper Alloy Forging Rod, Bar, and Shapes 1 This standard is issued under the fixed designation B 124/B 124M; the number immediately following

More information

Development of a water code of practice for internal plumbing in Kuwait

Development of a water code of practice for internal plumbing in Kuwait Water Resources Management VII 97 Development of a water code of practice for internal plumbing in Kuwait M. Al-Senafy, E. Azrag, M. Al-Otaibi & A. Al-Khalid Hydrology Department, Water Resources Division,

More information

2015 International Green Construction Code. Dave Walls International Code Council

2015 International Green Construction Code. Dave Walls International Code Council 2015 International Green Construction Code Dave Walls International Code Council Introduction - International Code Council Sustainability ICC Green Codes and Standards Why a Green Code IgCC and CALGreen

More information

ICC-ES Report. PMG-1009 Reissued 10/2017 This report is subject to renewal 10/2018 EPIPE EPOXY LINED PIPING SYSTEM ACE DURAFLO SYSTEMS, LLC

ICC-ES Report. PMG-1009 Reissued 10/2017 This report is subject to renewal 10/2018 EPIPE EPOXY LINED PIPING SYSTEM ACE DURAFLO SYSTEMS, LLC ICC-ES Report PMG-1009 Reissued 10/2017 This report is subject to renewal 10/2018 EVALUATION SUBJECT: EPIPE EPOXY LINED PIPING SYSTEM DIVISION: 22 00 00 PLUMBING SECTION: 22 11 16 DOMESTIC WATER PIPING

More information

International Building Code Chapter 16 Part 3 File Type

International Building Code Chapter 16 Part 3 File Type We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with international building

More information

BUILDING CONSTRUCTION

BUILDING CONSTRUCTION BUILDING CONSTRUCTION Chapter 66 From the CODE of the TOWN OF WINDHAM COUNTY OF CUMBERLAND STATE OF MAINE 66-1. Purpose. The Town of Windham enforces the Maine Uniform Building and Energy Code ( M.U.B.E.C.

More information

PIPING SPECIALTIES 15120

PIPING SPECIALTIES 15120 5925 West 148th Street Apple Valley, MN 55124 Phone: (800) 321-4739 Phone: (952) 891-2000 Fax: (952) 891-1409 www.wirsbo.com This specification is a manufacturer-specific proprietary product specification

More information

The Rehabilitation of Existing Building Drains and Building Sewers by the

The Rehabilitation of Existing Building Drains and Building Sewers by the Inversion or Pulled-in-Place Method and Curing of Resin-impregnated Tube Page 1 of 7 www.icc-es.org/pmg (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council PROPOSED PMG LISTING

More information

Dave Harper, Building Official (509) Susan Davis, Administrative Secretary (509)

Dave Harper, Building Official (509) Susan Davis, Administrative Secretary (509) City of Colville Building Department The Building Department is responsible for the issuance of permits for commercial and residential construction projects within the city. This responsibility includes

More information

EVALUATION SUBJECT: IPEX AQUARISE CPVC HOT- AND COLD- POTABLE WATER DISTRIBUTION SYSTEM

EVALUATION SUBJECT: IPEX AQUARISE CPVC HOT- AND COLD- POTABLE WATER DISTRIBUTION SYSTEM ICC-ES Report PMG-1156 Reissued 08/2018 This report is subject to renewal 08/2019 EVALUATION SUBJECT: IPEX AQUARISE CPVC HOT- AND COLD- POTABLE WATER DISTRIBUTION SYSTEM DIVISION: 22 00 00 PLUMBING SECTION:

More information

REINFORCING TABLES INSTALLATION MANUAL

REINFORCING TABLES INSTALLATION MANUAL REINFORCING TABLES 201 REINFORCING TABLES Design Limitations Introduction The structural wall reinforcing and lintel design tables contained within the Appendix of NUDURA s Installation Manual have been

More information

(Contaminant) Backsiphonage or Backpressure Backsiphonage or Backpressure

(Contaminant) Backsiphonage or Backpressure Backsiphonage or Backpressure Premises where the water supplier is denied access or restricted access for survey Premises where the water is being treated by the addition of chemical or other additives * Refer to OAR 333-061-0070(8)

More information

!"#$%!&'!(#)*+,-)+.!/0&/#0%-#$

!#$%!&'!(#)*+,-)+.!/0&/#0%-#$ !!"#$%%!&'(!)*++*,-% NSF Certified to: -!"#$%& -!"#$'% - (")*$#%+,- -."($/%0-12 NSF - pw - 34.$5678 S t a n d a r d s/c o d e c o m p li e d t o: ASTM F1807 ASTM F858 CSA B137.5 NSF 14 NSF 61!"#$%!&'!(#)*+,-)+.!/0&/#0%-#$

More information

City Council Agenda Item Report January 5, 2016

City Council Agenda Item Report January 5, 2016 City Council Agenda Item Report January 5, 2016 Agenda Item Contact Stanley R. Fees, P.E., CFM City Engineer 312-0084 sfees@ci.buda.tx.us SUBJECT: Presentation on Possible Adoption of ICC Building Codes

More information

PORT OF SAN FRANCISCO PLUMBING CODE. Based on the 2016 California Plumbing Code

PORT OF SAN FRANCISCO PLUMBING CODE. Based on the 2016 California Plumbing Code 2016 PORT OF SAN FRANCISCO PLUMBING CODE Based on the 2016 California Plumbing Code The complete 2016 Port of San Francisco Plumbing Code adopts and amends the 2016 edition of the California Plumbing Code.

More information

CITY OF CHEYENNE 2018 CODE ADOPTIONS

CITY OF CHEYENNE 2018 CODE ADOPTIONS CITY OF CHEYENNE 2018 CODE ADOPTIONS Town Hall meeting 9-25-18 Public Safety Center 415 W. 18 th St Blas Hernandez CBO bhernandez@cheyennecity.org PH: 307-637-6276 Proposed changes are visible by visiting

More information

Standard Specification for Brass Rod, Bar, and Shapes 1

Standard Specification for Brass Rod, Bar, and Shapes 1 Designation: B 2 03 Standard Specification for Brass Rod, Bar, and Shapes This standard is issued under the fixed designation B 2; the number immediately following the designation indicates the year of

More information

NC State Building Codes Amendments - Effective 1/1/2019. (Note: some amendments may indicate earlier effective dates)

NC State Building Codes Amendments - Effective 1/1/2019. (Note: some amendments may indicate earlier effective dates) NC State Building Codes Amendments - Effective 1/1/2019 (adopted September 2017 through June 2018) (Note: some amendments may indicate earlier effective dates) The North Carolina Codes are available at

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR ANCHORED MASONRY VENEER SYSTEM WITH POLYSTYRENE FOAM PLASTIC BACKING EC 021-2014 (Adopted

More information

ADOPTED REGULATION OF THE STATE ENVIRONMENTAL COMMISSION. LCB File No. R049-18

ADOPTED REGULATION OF THE STATE ENVIRONMENTAL COMMISSION. LCB File No. R049-18 ADOPTED REGULATION OF THE STATE ENVIRONMENTAL COMMISSION LCB File No. R049-18 EXPLANATION Matter in italics is new; matter in brackets [omitted material] is material to be omitted. AUTHORITY: 1-23, NRS

More information

Section Domestic Water Piping (Hot and Cold Water Potable Water Distribution)

Section Domestic Water Piping (Hot and Cold Water Potable Water Distribution) Domestic Water Piping 22 11 16 Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 Toll Free: (800) 321-4739 Phone: (952) 891-2000 Fax: (952) 891-2008 www.uponor-usa.com This specification is a

More information

Standard Specification for Nickel-Copper Alloy (UNS N04400)* Seamless Pipe and Tube 1

Standard Specification for Nickel-Copper Alloy (UNS N04400)* Seamless Pipe and Tube 1 Designation: B 65 05 Standard Specification for Nickel-Copper Alloy (UNS N04400)* Seamless Pipe and Tube This standard is issued under the fixed designation B 65; the number immediately following the designation

More information

Department of Public Safety and Corrections Uniform Construction Code Council. Uniform Construction Code (LAC 55:VI.301)

Department of Public Safety and Corrections Uniform Construction Code Council. Uniform Construction Code (LAC 55:VI.301) Department of Public Safety and Corrections Uniform Construction Code Council Uniform Construction Code (LAC 55:VI.301) In accordance with the provisions of R.S. 40:1730.26 and R.S. 40:1730.28, relative

More information

Standard Specification for Seamless and Welded Austenitic Stainless Steel Sanitary Tubing 1

Standard Specification for Seamless and Welded Austenitic Stainless Steel Sanitary Tubing 1 Designation: A 270 01 An American National Standard Standard Specification for Seamless and Welded Austenitic Stainless Steel Sanitary Tubing 1 This standard is issued under the fixed designation A 270;

More information

Standard Specification for Ferritic/Austenitic (Duplex) Stainless Steel Pipe Electric Fusion Welded with Addition of Filler Metal 1

Standard Specification for Ferritic/Austenitic (Duplex) Stainless Steel Pipe Electric Fusion Welded with Addition of Filler Metal 1 Designation: A 928/A 928M 04 www.tubingchina.com Standard Specification for Ferritic/Austenitic (Duplex) Stainless Steel Pipe Electric Fusion Welded with Addition of Filler Metal 1 This standard is issued

More information

PMG-1039 Effective Date: April 1, 2014 This listing is subject to re-examination in one year.

PMG-1039 Effective Date: April 1, 2014 This listing is subject to re-examination in one year. ICC-ES PMG Listing PMG-1039 Effective Date: April 1, 2014 This listing is subject to re-examination in one year. www.icc-es-pmg.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code

More information

Cannabis Related Occupancies Commercial Building Permit Application Submittal Requirements

Cannabis Related Occupancies Commercial Building Permit Application Submittal Requirements Cannabis Related Occupancies Commercial Building Permit Application Submittal Requirements The following regulations pertain to City of Sacramento Building Division and Fire Department requirements for

More information

Chapter 1: Application and Administration

Chapter 1: Application and Administration Chapter 1: Application and Administration General Comments This chapter provides provisions regarding the purpose, scope, application, and administration of subsequent requirements of ICC 500. In addition

More information

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below) CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX C - ALTERNATE PLUMBING SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority

More information

House Bill 4086 Ordered by the House February 21 Including House Amendments dated February 21

House Bill 4086 Ordered by the House February 21 Including House Amendments dated February 21 th OREGON LEGISLATIVE ASSEMBLY--0 Regular Session A-Engrossed House Bill 0 Ordered by the House February Including House Amendments dated February Introduced and printed pursuant to House Rule.00. Presession

More information

Chan Bill (AB1953) California SB1334 & SB1395 NSF Standard 61, Annex G. January 15, 2009

Chan Bill (AB1953) California SB1334 & SB1395 NSF Standard 61, Annex G. January 15, 2009 Chan Bill (AB1953) California SB1334 & SB1395 NSF Standard 61, Annex G January 15, 2009 1 California AB1953 Effective January 1, 2010 lead free means: Not more than 0.2% lead for solder and flux Not more

More information

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date ORDINANCE AN ORDINANCE OF THE COMMISSION OF KNOX COUNTY, TENNESSEE RESCINDING ARTICLE III. CABO ONE- AND TWO-FAMILY DWELLING CODE, SEC. 10-56, SEC. 10-57 AND SEC. 10-58 AND ADOPTING THE 2006 INTERNATIONAL

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 Toll Free: (800) 321-4739 Phone: (952) 891-2000 Fax: (952) 891-1409 www.uponor-usa.com This specification is a manufacturer-specific proprietary

More information

Errata for the 2003 Uniform Plumbing Code Study Guide (5th Printing)

Errata for the 2003 Uniform Plumbing Code Study Guide (5th Printing) Errata for the 2003 Uniform Plumbing Code Study Guide (5th Printing) The following is a list of changes that we found after the fifth printing of the 2003 Uniform Plumbing Code Study Guide. These changes

More information

2013 R-1 Building Permit Package For Additions, Decks, Fences & Garages

2013 R-1 Building Permit Package For Additions, Decks, Fences & Garages 2013 R-1 Building Permit Package For Additions, Decks, Fences & Garages Table of Contents Application for Building Permit 3 Sewer Connection Permit.. 4 Water Connection Permit... 5 Application for Utility

More information

A. Product Data: For Piping, fittings, transition fittings and dielectric fittings.

A. Product Data: For Piping, fittings, transition fittings and dielectric fittings. SECTION 22 11 16 - DOMESTIC WATER PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Fences, hedges, and walls may be permitted in the various districts as accessory uses in accordance with the following limitations: (A)

Fences, hedges, and walls may be permitted in the various districts as accessory uses in accordance with the following limitations: (A) ORDINANCE NO. 1927 AN ORDINANCE ADDING SECTION 17-04-467, SOUND WALL, TO THE BROOMFIELD MUNICIPAL CODE AND AMENDING BROOMFIELD MUNICIPAL CODE SECTION 17-04-500, SWIMMING POOL AND SECTION 17-32-140, FENCES,

More information

Standard Specification for UNS N08020, UNS N08024, and UNS N08026 Nickel Alloy Bar and Wire 1

Standard Specification for UNS N08020, UNS N08024, and UNS N08026 Nickel Alloy Bar and Wire 1 Designation: B 473 96 (Reapproved 2002) e Standard Specification for UNS N08020, UNS N08024, and UNS N08026 Nickel Alloy Bar and Wire This standard is issued under the fixed designation B 473; the number

More information

2014 Lead Requirements US SDWA Act. CA/NV AWWA October 1, 2013

2014 Lead Requirements US SDWA Act. CA/NV AWWA October 1, 2013 2014 Lead Requirements US SDWA Act CA/NV AWWA October 1, 2013 Topics US Safe Drinking Water Act Revision lead content Questions and EPA Guidance Comparison with CA Health and Safety Code Standards and

More information

Westtown Township Building Permit Application Instructions Notes:

Westtown Township Building Permit Application Instructions Notes: Building Permit Application Instructions Notes: All work performed in conjunction with this permit shall conform with the Pennsylvania Uniform Construction Code (PA UCC), all current adopted building codes,

More information

Table of Contents Part One Supplement Part Two Supplement Part Three Supplement BOLD

Table of Contents Part One Supplement Part Two Supplement Part Three Supplement BOLD 2016 Code Update Based upon The 2015 International Codes and The 2016 Uniform Code Supplement and the 2015 Supplement to the NYS Energy Conservation Construction Code Important Notice: The text in this

More information

Committee Responsibilities Matrix 2018 International Plumbing Code February 2017

Committee Responsibilities Matrix 2018 International Plumbing Code February 2017 Subject Administrative Provisions Chapter 1 Defined Terms Chapter 2 Alterations to trusses 2018 Chapter 1 Chapter 2 Committee Responsibilities Matrix Maintained by ADM Various 2018-2020 Maintained by Proposed

More information

Standard Specification for Aluminum-Coated Steel Chain-Link Fence Fabric 1

Standard Specification for Aluminum-Coated Steel Chain-Link Fence Fabric 1 Designation: A 491 07 Standard Specification for Aluminum-Coated Steel Chain-Link Fence Fabric 1 This standard is issued under the fixed designation A 491; the number immediately following the designation

More information

Standard Specification for Seamless and Welded Austenitic and Ferritic/Austenitic Stainless Steel Sanitary Tubing 1

Standard Specification for Seamless and Welded Austenitic and Ferritic/Austenitic Stainless Steel Sanitary Tubing 1 Designation: A 270 03 Standard Specification for Seamless and Welded Austenitic and Ferritic/Austenitic Stainless Steel Sanitary Tubing 1 This standard is issued under the fixed designation A 270; the

More information

Patchwork Blue. Survey of U.S. Rainwater Harvesting Laws. Chris Maxwell-Gaines, P.E.

Patchwork Blue. Survey of U.S. Rainwater Harvesting Laws. Chris Maxwell-Gaines, P.E. Patchwork Blue Survey of U.S. Rainwater Harvesting Laws Chris Maxwell-Gaines, P.E. Snopes.com Screenshot Guidelines Standards Codes Laws Regulations International Plumbing Code (IPC) International

More information

ELIGIBILITY CHECKLIST FOR EXPEDITED SOLAR DOMESTIC WATER HEATER PERMITTING

ELIGIBILITY CHECKLIST FOR EXPEDITED SOLAR DOMESTIC WATER HEATER PERMITTING Building and Safety Division ELIGIBILITY CHECKLIST FOR EXPEDITED SOLAR DOMESTIC WATER HEATER PERMITTING GENERAL REQUIREMENTS A. System size is 30 kwth (462 square feet of collector) or less Y N B. The

More information

2018 SELECT IRC OPTIONS FOR USE WITH THE 2015 MICHIGAN RESIDENTIAL CODE

2018 SELECT IRC OPTIONS FOR USE WITH THE 2015 MICHIGAN RESIDENTIAL CODE 2018 SELECT IRC OPTIONS FOR USE WITH THE 2015 MICHIGAN RESIDENTIAL CODE 2018 Select IRC Options for Use with the 2015 Michigan Residential Code ISBN: 978-1-60983-856-0 Project Head: Hamid Naderi Publications

More information

Backflow Preventer Tester Plumbing License Code Path

Backflow Preventer Tester Plumbing License Code Path Backflow Preventer Tester Plumbing License Code Path P.A. 733 State Plumbing Act P.A. 230 State Construction Code Act P.A. 399, Part 14 Cross Connection Control Rules Michigan Plumbing Code International

More information

RELIABLE PIPES & TUBES LTD.

RELIABLE PIPES & TUBES LTD. RELIABLE PIPES & TUBES LTD. OHSAS 800:2007 CERTIFIED ISO 900:2008 CERTIFIED ISO 400:2004 CERTIFIED PED CERT NO 0 202 IND/Q--00 GOVT. RECOGNIZED EXPORT HOUSE Manufacturer & Exporters of Monel, Inconel,

More information

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 9 - VENTS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)

More information

Phoenix Building Construction Code Updated Amendments to the Administrative Provisions

Phoenix Building Construction Code Updated Amendments to the Administrative Provisions Phoenix Building Construction Code Updated Amendments to the Administrative Provisions CHAPTER 1 ADMINISTRATION Section 101.2 Change to read as shown: 101.2 Scope. The provisions of this Code shall apply

More information

GENERAL CHAPTER 1. SCOPE AND ADMINISTRATION 101 GENERAL SCOPE

GENERAL CHAPTER 1. SCOPE AND ADMINISTRATION 101 GENERAL SCOPE GENERAL The commentary is designed to provide guidance for the implantation of the National Green Building Standard (NGBS) (ICC 700-2012). Where appropriate, the commentary includes basic background information

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS STANDARD FOR BACKFLOW PREVENTERS AND RELIEF VALVES IAPMO TS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS STANDARD FOR BACKFLOW PREVENTERS AND RELIEF VALVES IAPMO TS INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS STANDARD FOR BACKFLOW PREVENTERS AND RELIEF VALVES IAPMO TS 8-20069 1. PURPOSE 1.1 The purpose of this standard is to establish an acceptable

More information

Rescinds Ordinance Number (CM) EFFECTIVE JANUARY 1, Table of Contents

Rescinds Ordinance Number (CM) EFFECTIVE JANUARY 1, Table of Contents CITY COUNCIL 6.H. ORDINANCE NO. (CM) AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF WATSONVILLE AMENDING TITLE 8 (BUILDING REGULATIONS) BY ADOPTING CERTAIN CHAPTERS PERTAINING TO THE ADOPTION BY REFERENCE

More information

Standard Specification for Centrifugally Cast Ferritic Alloy Steel Pipe for High- Temperature Service 1

Standard Specification for Centrifugally Cast Ferritic Alloy Steel Pipe for High- Temperature Service 1 Designation: Standard Specification for Centrifugally Cast Ferritic Alloy Steel Pipe for High- Temperature Service 1 This standard is issued under the fixed designation A 426/A 426M; the number immediately

More information