1 Generic Spec TECH DATA SHEET Sections / / ICC ESR-2503 L.A. RR#: Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections / / Fluid Applied Waterproofing Product Name Manufactured by Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent longterm stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Retaining Walls: Waterproof below-grade, concrete, block walls, basements, etc. Planters: Waterproof planters and other landscaping features. In-between slab waterproofing: To provide a sandwich membrane in-between two concrete slabs or over wood decks that will receive a topping slab. Also used as an under-tile membrane when a mud-bed or thick-set type assembly is required. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on type of application and the type of surfaces it s being applied to. For specific application procedures, refer to, or download the appropriate installation instructions. (For Retaining Walls, refer to the Retaining Walls Installation Instructions. For Planters, refer to the Planters Installation Instructions, etc.) Basic installation procedures are also provided in the Spec Data Sheet of each type of installation. For a complete/comprehensive set of instructions, however, please refer to the Installation Instructions documents. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Use AVM Foam Board, AVM Drainage Boards or AVM Approved Protective Panels. Refer to the spec Data Sheets or to the Min Thickness Table for protection details. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: or or visit System Specifications See next page. Tech Data Sheet Rev. 09/2017 1/2 AVM Document # Generic
2 The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black gr/cm Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m2 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer /5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal lbs 19 Grams/Liter Retaining Wall with Aussie Membrane In-Between Slab Waterproofing Retaining Wall Concrete Slab Aussie Membrane Topping Slab Cant Strip Aussie Membrane Footing Block Walls with Aussie Membrane Planter with Aussie Membrane Aussie Membrane Aussie Membrane Block Wall Protection Board Block Wall Drainage Board Aussie Membrane Planter Wall Drainage Board Dirt Cant Strip Drainage Pipe Cant Strip Drainage Pipe Slope to Drain Footing Footing Drain For a complete list of details in CAD or PDF, please visit our website at Quality Waterproofing Products Tech Data Sheet Rev. 09/2017 2/2 AVM Document # Generic
3 Retaining Walls Spec TECH DATA SHEET Sections / / ICC ESR-2503 L.A. RR#: Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections / / Fluid Applied Waterproofing Product Name Manufactured by Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Retaining Walls: Waterproof below-grade, concrete, block walls, basements, etc. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc.. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application procedures only. For specific application procedures, download the appropriate installation instructions. Preparation 1. Make sure surface is even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16" wide. Pay special attention to shrinkage cracks between the blocks and the mortar at the block s joints. 2. If necessary, apply a thin slurry coat using AVM Crete Apply a 4"x4" mortar cant at 45 at the cold joints. (Where the block meets the footings) 4. Priming is highly recommended! Especially if surfaces are old, dusty or very dense (such as solid concrete) Always use AVM Primer 500 when installing over horizontal surfaces. Apply Primer using roller, brush or sprayer. Membrane Installation Roller/Brush: Apply a liberal coat of the Aussie Membrane 500 to all surfaces. (Roll up and down) Allow to cure until dry to the touch. Apply a second coat of the Aussie Membrane 500 going side to side. Allow to dry to the touch. Check for pinholes and proper thickness using a mil gauge. Make sure it=s a minimum 60 mils at all places when completely dry and 90 mils if still wet. Full cure is typically achieved after 24 hours. Drying times may vary based on temperature, humidity and other factors. Applying a third coat is highly recommended. Spray: Mix contents in bucket with drill and paddle for seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Check for thickness. (60 mils dry / 90 mils wet) Important Notes: mils dry on vertical block walls is highly recommended. 2. Although it is possible to spray 60 dry mils in one coat, doing so in two coats reduces the chances of leaving spots and pinholes uncovered or with too little product. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Install the AVM Drain Board 6000 and appropriate drainage system. Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: or or visit System Specifications See next page. Tech Data Sheet Rev. 09/2017 1/2 AVM Document # Retaining Walls
4 The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black gr/cm Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m2 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer /5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal lbs 19 Grams/Liter Slab on Grade at Top of Footing Earth Gravel Backfill (not required if drainage board used) Termination at Grade Backer Rod and Sealant by Others Concrete Wall Waterstop Slab on Grade over Vapor Barrier Drainage or Protection 60 mils *See note. Detail 45 ±5 mils with filter fabric Min 3 x3 Mortar Cant Strip Primer Termination Bar Paving with Protection or Drainage Board Gravel Perforated Drainage Pipe Top of Footing Less of Eq. 3 Note: For applications deeper than 6 feet, see Thickness Chart. For a complete list of details in CAD or PDF, please visit our website at Quality Waterproofing Products Tech Data Sheet Rev. 09/2017 2/2 AVM Document # Retaining Walls
5 Planters Spec TECH DATA SHEET Sections / / ICC ESR-2503 L.A. RR#: Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections / / Fluid Applied Waterproofing Product Name Manufactured by Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Planters: For waterproofing planters made of block or concrete. Important note: For Green Roofs (Roof Gardens) please refer to the Green Roofs Spec Data Sheet. Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application procedures only. For specific application procedures, download the appropriate installation instructions. Preparation 1. Make sure surface is even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16" wide. Pay special attention to shrinkage cracks between the blocks and the mortar at the block s joints. 2. If necessary, apply a thin slurry coat using AVM Crete Apply a 4"x4" mortar cant at 45 at the cold joints. (Where the block meets the footings) 4. Priming is highly recommended! Especially if surfaces are old, dusty or very dense (such as solid concrete) Always use AVM Primer 500 when installing over horizontal surfaces. Apply Primer using roller, brush or sprayer. Membrane Installation Roller/Brush: Apply a liberal coat of the Aussie Membrane 500 to all surfaces. (Roll up and down) Allow to cure until dry to the touch. Apply a second coat of the Aussie Membrane 500 going side to side. Allow to dry to the touch. Check for pinholes and proper thickness using a mil gauge. Make sure it=s a minimum 60 mils at all places when completely dry and 90 mils if still wet. Full cure is typically achieved after 24 hours. Drying times may vary based on temperature, humidity and other factors. Applying a third coat is highly recommended. Spray: Mix contents in bucket with drill and paddle for seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Check for thickness. (60 mils dry / 90 mils wet) Important Notes: mils dry is highly recommended. 2. Although it is possible to spray 60 dry mils in one coat, doing so in two coats reduces the chances of leaving spots and pinholes uncovered or with too little product. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. c. Perform a 24 hour water test whenever possible. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. First install a root barrier (such as ¼ Apoc Protective Panels) or other approved root barrier. Then, on horizontal surfaces, install AVM Drain Board On vertical surfaces, install AVM Drain Board Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: or or visit System Specifications See next page. Tech Data Sheet Rev. 09/2017 1/2 AVM Document # Planters
6 The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black gr/cm Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m2 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer /5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal lbs 19 Grams/Liter SOIL PROTECTION BOARD OR DRAINAGE BOARD 60 MIL AVM SYSTEM 500 AUSSIE MEMBRANE 500 PRIMER 500 CONCRETE WEEP SCREED SHEET METAL FLASHING TERMINATION BAR SOIL PROTECTION BOARD OR AVM DRAINAGE BOARD 60 MIL AVM SYSTEM 500 AUSSIE MEMBRANE 500 PRIMER 500 EXTERIOR WALL PLANTER PLANTER PLANTER SLOPE CONCRETE TO DRAIN AVM SYSTEM 500 AUSSIE MEMBRANE 500 DETAIL COAT AT 45 ± 5 MILS WITH REINFORCING FABRIC MIN 3 X 3 MORTAR CANT STRIP OTHER ACCEPTABLE TERMINATIONAS For a complete list of details in CAD or PDF, please visit our website at Quality Waterproofing Products Tech Data Sheet Rev. 09/2017 2/2 AVM Document # Planters
7 Topping Slabs Waterproofing TECH DATA SHEET Sections / / ICC ESR-2503 L.A. RR#: Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections / / Fluid Applied Waterproofing Product Name Manufactured by Product Description The AVM is a Water- Based rubber/bitumen liquid membrane modified with high performance rubberized polymers giving it excellent adhesion, which dries to a tough, black seamless flexible waterproof membrane. The Aussie Membrane 500 is a single component thixotropic coldapplied bitumen paste that exhibits excellent elongation and recovery properties. The AVM has excellent long-term stability (maintains its properties over very long periods of time) un-like other below grade systems (including polyurethane based systems) that Crack and become brittle as they age. Where to Use Between Slabs / Topping Slabs / Hard Rock: For waterproofing between two slabs, under topping slabs, under hard rock and other sandwiched applications. Important notes: May be applied over concrete or plywood substrates. (See details) Warranty AVM Industries will warranty the installed membrane for a period of five (5) years. Ten (10) year warranties are also available. For complete warranty details, contact AVM Industries or consult with your applicator. Delivery, Storage, and Handling a. Delivery of all the materials to the job site must be in their original sealed containers, with manufacturer s name and label intact. b. Handle and store containers in accordance with printed instructions. c. Store at temperatures between 50 F and 90 F. Do not store materials in direct sunlight or where they may be damaged by water or rain. d. Failure to comply with the recommended storage conditions may result in premature deterioration of the product. For specific storage advice, please contact AVM Industries and/or its representatives. e. Keep all materials out of the reach of children. f. If irritation occurs during use, liberally flush affected areas with water. If irritation continues, see a physician immediately. Project Conditions 1. All surfaces to which the Aussie Membrane 500 is applied to must be sound and stable, with an even finish and free from dust, loose debris, grease, curing agents, etc.. 2. The may be applied to damp but not waterlogged surfaces (Green Concrete) 3. Do not apply materials at temperatures below 40 F and falling or if precipitation is imminent. Do not apply materials in direct sunlight at temperatures above 100 F or rising. 4. Warn personnel against hazards of materials to skin and eyes. Note other hazardous conditions on the job that might require special protective gear and or any other special protective or safety procedures. 5. Protect adjacent surfaces which could be damaged during the application procedure. 6. This system must not be used to cover Expansion Joints. System Application Read the Installation Instructions Prior to Installation. Application instructions vary based on application surfaces. Following are common (Generic) application instructions for applications over concrete only. For detailed installation instructions, download the appropriate installation instructions. Preparation 1. Make sure concrete surfaces are even without holes, gaps, etc. Make sure substrate has no cracks larger than 1/16 wide. (If applying over plywood substrates, refer to the Between Slab Installation Instructions and Details for more information) 2. If necessary, apply a thin slurry coat using AVM Crete Apply a 1x1 mortar cant at 45 at horizontalto-vertical transitions. Then apply a detail coat. (See details) 4. Primer: Apply AVM Primer 500 using a roller, brush or sprayer to all surfaces and allow to dry to the touch before installing the Aussie Membrane 500. Membrane Installation Roller/Brush: Apply liberal coats of the Aussie Membrane 500 to all surfaces until the desired thickness is achieved. (see AVM Aussie Membrane Min Thickness Table for more info) Allow to cure between coats. Check for pinholes, bubbles and proper thickness using a mil gauge. Fix any imperfections as needed. Full cure is typically achieved after hours after the final coat was installed. Drying times may vary based on temperature, humidity and other factors. Spray: Mix contents in bucket with drill and paddle for seconds. Product will thin out significantly. (The thinning does not affect performance) Do NOT add water! Use an airless sprayer to apply. Apply product until saturated but stop before dripping or sagging occurs. Once dry to the touch, apply a second coat spraying in the other direction. Continue to apply coats until the desired thickness is achieved. Important Notes: It s better to apply multiple thin coats Vs. one or two thick coats. Applying coats too thick could cause material to crust over and slow down curing times. It could also lead to bubbling and delaminations. Quality Control a. Visually inspect all coated surfaces to ensure a full and proper coating application, especially at corners, drainage footings and other hard-to-reach areas. b. All unsatisfactory areas shall be repaired prior to final acceptance. Protection of Installed Work a. The completed section shall be protected for the first 24 hours after application or until the surface is sufficiently cured. (The amount of drying time may vary depending on temperature and humidity conditions) b. Always protect the waterproofing from possible damage. Install optional protective Panels and appropriate AVM Drainage Boards. Refer to Technical Details, Min Thickness Table and Installation Instructions for more info. Availability and Cost Contact AVM Industries or your approved applicator for pricing and availability. Technical Services Technical services are available by contacting our offices at: or or visit System Specifications See next page. Tech Data Sheet Rev. 09/2017 1/2 AVM Document # Topping Slabs
8 The following coverages are based on controlled tests. Actual coverages may vary. Technical Information Color Specific Gravity Coverage: (Varies depending on substrate) Flash Point Service Temperature Application Temperature Dark brown. After drying: black gr/cm Dry Mills Non-flammable 15ºF-177ºF (-10ºC to +80ºC) 42ºF-132ºF (+5ºC to 55ºC) Solid Content 64% Tensile Strength >15.4 Lbs (>7 kg) ASTM D 412 Elongation at break >1000% ASTM D 412 Resistance to water pressure 1 tm 24 hr Passed ASTM D751 Water vapor transmission 4.0 gr/m2 24 hr ASTM D 96 Recovery 85% IS 1536 Creep At 177ºF (80ºC) No Creep DIN Resistance to Standing Water Passed ASTM D 2939 Bacterial Attack in soil ºF (40ºC) Passed ASTM D 2939 Crack bridging >3/16" (>5mm) IS 1731 Certifications ISO 9002, Green Label, I.Q. Net (International Certification Network) Item / Component Packaging Approx Shipping Weights VOC AVM Primer /5.0 gal. pails 2.0/5.0 gal. 15/39 lbs. 15 Grams/Liter AVM 5.0 gal. pails 5.0 gal lbs 19 Grams/Liter Topping slab Topping slab Min. 120 mil fully reinforced (consult w/avm for membrane thickness requirements) Min. 120 mil fully reinforced (consult w/avm for membrane thickness requirements) For a complete list of details in CAD or PDF, please visit our website at Quality Waterproofing Products Tech Data Sheet Rev. 09/2017 2/2 AVM Document # Topping Slabs
AVM System 500. Aussie Membrane 500
Generic Spec TECH DATA SHEET Sections - 071000 / 071400 / 071416 ICC ESR-2503 L.A. RR#: 25550 Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections 071000 / 071400 / 071416 Fluid Applied Waterproofing
More informationDelivery, Storage, and Handling
TECH DATA SHEET Sections - 071000 / 071300 / 071313 / 071326 / 071352 AVM Aussie Mate 580-AL UV Stable Heavy Duty 60 Mil Bellow Grade Bituminous Waterproofing Sheet Membrane, with Aluminum Backing Product
More informationAussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling
L.A. RR#: 26044 TECH DATA SHEET Sections - 071000 / 071300 / 071353 / 071354 Aussie Skin 550 Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane Section 071000 / 071300 / 071353 / 071354
More informationAussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling
L.A. RR#: 26044 TECH DATA SHEET Sections - 071000 / 071300 / 071353 / 071354 Aussie Skin 550 Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane Approved for Shot Crete Section 071000
More informationDivision 7-Moisture Protection Section 7-Under Tile Waterproofing Exceeds ANSI A Rev. 05/2012 Page 1
Page 1 Table of Contents General... 2 Approvals... 2 Applicator... 2 Product Delivery, Storage and Handling... 2 Limitations... 2 Safety... 2 Tools Needed for Application... 2 Products... 2 AVM System
More information8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane
8245 Remmet Ave Canoga Park, CA. 91304 (888) 414-1041 Division 7-Moisture Protection Page 1 Table of Contents General... 2 Approvals... 2 Applicator... 2 Product Delivery, Storage and Handling... 2 Limitations...
More informationAVM Drain Board 2000/2020
TECH DATA SHEET Sections - 334600 / 334613 / 334616 / 334619 / 334633 AVM Drain Board 2000/2020 Sections 334600 / 334613 / 334616 / 334619 / 334633 Product Name AVM Drain Board 2000 / 2020 Manufactured
More informationSECTION SELF-ADHERING SHEET FLASHING
MANUFACTURER S GUIDE SPECIFICATIONS SECTION 076526 SELF-ADHERING SHEET FLASHING 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 604129 03.24.15 Carlisle, Flexphalt, Sure-Seal and CAV-GRIP
More informationDAYSONFAST Table of Contents
DAYSONFAST Table of Contents What is DAYSONFAST? 4 DAYSONFAST Areas Of Application 5 DAYSONFAST Benefits And Advantages 8 DAYSONFAST Technical Specifications 9 DAYSONFAST General Instructions 10 DAYSONFAST
More informationSECTION mil thickness COLD FLUID-APPLIED WATERPROOFING
SECTION 07 14 16 CCW-MIRASEAL @ 120 mil thickness COLD FLUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationSECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING
SECTION 07143 CCW-MIRASEAL @ 120 mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More information"WE CAN AGUASEAL THAT" AGUASEAL WATERPROOFING SYSTEMS A G U A B A S E
"WE CAN AGUASEAL THAT" AGUASEAL WATERPROOFING SYSTEMS A G U A B A S E A G U A B A S E WHAT IS AGUABASE? AguaBase is utilized worldwide as a waterproofing system for below grade foundation walls, steel
More informationSECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING
SECTION 07143 CCW-MIRASEAL @ 120 mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationSECTION MODIFIED BITUMINOUS SHEET WATERPROOFING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 13 52 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph
More informationBITUTHENE Deck System
BITUTHENE Deck System Cold-applied, waterproofing system for inverted roofs, green roofs and elevated decks Product Description BITUTHENE Deck System combines BITUTHENE 4000 sheet membranes with BITUTHENE
More informationPol-E-Base Modified Bitumen Roof System
Pol-E-Base Modified Bitumen Roof System Specification Chemicals, Inc. produces the Pol-E-Base Built-up Roofing System as the ultimate in field applied reflective insulation roofing. It has the advantages
More informationWPM WATERPROOFING MEMBRANE
WPM 300 - WATERPROOFING MEMBRANE Description WPM 300 Waterproofing Membrane is a single-pack, water based polyurethane modified synthetic rubber polymer, liquid membrane developed specifically as a tough,
More informationMANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More informationMANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More informationPacific Polymers Elasto-Mat D&G Guide Specification
1 07141-1 August 2016 Pacific Polymers Elasto-Mat D&G Guide Specification SECTION 07141 FLUID APPLIED WATERPROOFING 2 07141-2 August 2016 Pacific Polymers Elasto-Mat D&G Guide Specification SECTION 07141
More informationPacific Polymers Elasto-Deck 5000X2 Guide Specification
1 071813-1 July 2018 Pacific Polymers Elasto-Deck 5000X2 Guide Specification SECTION 071813 TRAFFIC COATINGS ELASTO-DECK 5000X2 OVER CONCRETE 2 071813-2 July 2018 Pacific Polymers Elasto-Deck 5000X2 Guide
More informationBAYBLOCK HT/BAYBLOCK HT BASE
Characterization Properties / Applications Bayblock HT is a technologically advanced, high-solids, alkali resistant, thixotropic,acrylic elastomeric coating. Bayblock HT is formulated for the protection
More informationFireShield Restoration Specifications - EPDM
FireShield Restoration Specifications - EPDM Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com FIRESHIELD Restoration Specifications EPDM PART 1 GENERAL
More informationPacific Polymers Elasto-Deck 5000MR Guide Specification
1 071813-1 July 2018 Pacific Polymers Elasto-Deck 5000MR Guide Specification SECTION 071813 TRAFFIC COATINGS ELASTO-DECK 5000MR OVER CONCRETE 2 071813-2 July 2018 Pacific Polymers Elasto-Deck 5000MR Guide
More informationSECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof
SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812
More information900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable
900HA (US Version) Fast-cure, hand-applied liquid waterproofing membrane Product Description 900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable after
More informationASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS
ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS Re-Ply Roofing Systems Application Specification # AC - 2010-A & MB PART I GENERAL 1.01 DESCRIPTION A. This guideline specification includes
More informationGUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE
GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE SECTION 07 13 26 SELF-ADHERING SHEET WATERPROOFING Specifier Notes: This guide specification is written according to the Construction
More informationPEKAY T570 RUBBERSEAL
PEKAY T570 RUBBERSEAL DESCRIPTION Pekay Rubberseal T570 is a rubber-latex modified anionic bitumen emulsion, which dries to a pliable, flexible, waterproof, black coating. It may be used for a variety
More informationSECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING
SECTION 07 13 26 PART 1 - GENERAL 1.1 SUMMARY A. Scope: 1. Apply waterproofing to: a. Exterior of walls below grade: 1) Waterproofing shall include exterior of walls surrounding elevator pits and sumps.
More informationInstruction Guide APPLICATION OF CIM TO CONCRETE
23 Elm St., Peterborough, NH 03458 Tel: (800) 543-3458 (603) 924-9481 Fax: (603) 924-9482 Web site: Instruction Guide APPLICATION OF CIM TO CONCRETE 1.0 DESCRIPTION This guide covers the installation of
More informationWestbuild PRO. Rapid Drying Wet Area Waterproofing. Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane.
Westbuild PRO Rapid Drying Wet Area Waterproofing Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane. Westbuild PRO Wet Area Waterproofing is highly flexible
More informationE. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.
DELTA -DRAIN Section 07 10 00 Dampproofing and Waterproofing PART 1 GENERAL 1.1 SECTION INCLUDES A. Below grade drainage sheets. B. Plaza deck and planter drainage sheets. 1.2 RELATED SECTIONS A. Section
More informationStudent Services & Classroom Addition
SECTION 071326 - SELF-ADHERING SHEET WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationDESCRIPTION FEATURES AND BENEFITS AREAS OF USE. Showers & Bathrooms. Balconies & Patios SUITABLE SUBSTRATES. for application on: Concrete & Masonry
Product Information Technical Data Sheet - August 2017 High Performance DESCRIPTION Crommelin High Performance Under-tile Waterproof Membrane is an exceptionally flexible, 2 part cementitious, positive
More informationA. The work of this section includes, but is not limited to, the following:
SECTION 07 14 00 FLUID APPLIED WATERPROOFING SYSTEM PART 1: GENERAL 1.1 RELATED DOCUMENTS A. All of the Contract Documents, including General and Supplementary Conditions and Division 01 General Requirements,
More informationA. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.
I. GENERAL ACRYSHIELD SPF ROOFING SYSTEM Installation Guide Specification SPF Vapor Retarder System 07500 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide labor, materials,
More informationSECTION FLUID-APPLIED WATERPROOFING
SECTION 07140 FLUID-APPLIED WATERPROOFING PART 1 GENERAL 1.1 SUMMARY A. Section includes fluid applied rubberized asphalt and/or elastomeric membrane waterproofing; and surface dusting and/or protective
More informationShower Waterproofing Membrane Under tile and wet area waterproofing membrane.
Product Information Technical Data Sheet - December 2017 Shower Waterproofing Membrane Under tile and wet area waterproofing membrane. DESCRIPTION Crommelin Shower Waterproofing Membrane is a waterbased,
More informationFLUID APPLIED WATERPROOFING
SECTION 07120 FLUID APPLIED WATERPROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 09200 - Metal Studs, Metal Lath, Suspension Ceilings, Plaster, and Stucco.
More informationGuideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing
221 Brooke Street Media, PA 19063 610-566-7470 Fax 610-891-0834 Website www.acrymax.com e-mail info@acrymax.com This document is intended to provide guidelines for the proper specification and application
More information***********************************************************************************
AQUAFIN-2K/M Two-Component Cement-based Acrylic-based Waterproofing GUIDE AQUAFIN, Inc. SPECIFICATION PART 1 - GENERAL 1.1 SECTION INCLUDES SECTION 07 16 14 ACRYLIC MODIFIED (FLEXIBLE) CEMENTITIOUS WATERPROOFING
More informationTraffic Bearing Membrane
7 07 18 11 Traffic Coatings Qualideck Traffic Bearing Membrane High-solids, 2-component polyurethane waterproofing, traffic bearing systems for vehicular and pedestrian areas PACKAGING Q152 Primer: 3 gal
More informationSOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY
SOLAR COATING SYSTEMS 2-PLY EMULSION MULSION/A /ACRYLIC SYSTEM Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY Name Address City, State, zip A. Furnish and install a seamless, reinforced
More informationDIVISION 7 MARFLEX 5000 FLUID APPLIED AIR & VAPOR BARRIER - 3 PART SPEC 07262
Marflex Building Solutions 6866 Chrisman Lane / Middletown, OH 45042 Phone: (800) 498-1411 / Phone: (513) 422-7285 Fax: (513) 422-7282 E-mail: technicalsupport@mar-flex.com www.mar-flex.com This specification
More informationSECTION TW-60 Self-Adhering Sheet Waterproofing Membrane
This three-part specification is for design professionals for use as a guide and must be edited to delete information and instructions not required on a particular project. Delete the specifier notes in
More informationPacific Polymers Elasto-Deck BT Guide Specification
1 07141-1 August 2016 Pacific Polymers Elasto-Deck BT Guide Specification SECTION 07141 FLUID APPLIED WATERPROOFING 2 07141-2 August 2016 Pacific Polymers Elasto-Deck BT Guide Specification SECTION 07141
More informationA. Submit product data sheets and literature verifying fire ratings and physical properties of materials.
I. GENERAL ACRYSHIELD ROOF MANAGEMENT SYSTEM Installation Guide Specification For Preserving BUR & Mod Bit Roofs 07560 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide
More informationE. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.
DELTA -DRAIN 6200 Section 07 10 00 Dampproofing and Waterproofing PART 1 GENERAL 1.1 SECTION INCLUDES A. Below grade waterproofing. B. Below grade drainage sheets. C. Plaza deck and planter drainage sheets.
More informationPROCOR Composite Waterproofing System
PROCOR Composite Waterproofing System Fluid-applied and sheet waterproofing system Product Description PROCOR Composite Waterproofing System, combining PROCOR 75 fluid-applied membrane with PROCOR Composite
More informationColphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate
Colphene BSW Training and Application Guide Colphene BSW Waterproofing Membrane. 1. Prepare substrate Substrate must be structurally sound. Surface must be free of voids, spalled areas, loose aggregate,
More informationCIM IG 13 11/06. Instruction Guide
23 Elm St., Peterborough, NH 03458 Tel: (800) 543-3458 (603) 924-9481 Fax: (603) 924-9482 Web site: Instruction Guide APPLICATION OF CIM 2000 TO CONCRETE 1.0 DESCRIPTION This guide covers the installation
More informationSection Pre-Applied Sheet Membrane Waterproofing
Section 071324 Pre-Applied Sheet Membrane Waterproofing PART 1 GENERAL 1.01 SUMMARY A. The Work of this Section includes, but is not limited to, pre-applied sheet membrane waterproofing that forms an integral
More informationMaster-Seal Surface-Applied Waterproofing System
P 1/7 INDUSTRIAL ROOFING, INC. Master-Seal Surface-Applied Waterproofing System Master-Seal is a highly effective waterproofing system designed to seal surfaces from water seepage in roofs with minimum
More informationITEM 458 WATERPROOFING FOR STRUCTURES
ITEM 458 WATERPROOFING FOR STRUCTURES 458.1. Description. This Item shall govern for the furnishing and placing of waterproofing on concrete and steel bridge decks of railroad structures and on other structures
More informationSection COATING RESTORATION
80217R StoColor Lotusan Acrylic-Based, Vertical Above-Grade Exterior Wall Coating with Lotus-Effect Technology for Recoating Prepared, Previously Painted Surfaces Section 09 01 90.92 COATING RESTORATION
More information2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL. A. Two component liquid waterproofing for positive side waterproofing on mineral substrates
2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL 1.1 SECTION INCLUDES A. Two component liquid waterproofing for positive side waterproofing on mineral substrates 1.2 REFERENCES A. CE / EN1504-2 : 2005 Surface
More informationProduct Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification
Product Data Sheet Pondseal Waterproofing Membrane for Ponds and Water Features Description Pondseal is a polyurethane / acrylic co-polymer, water based coating which when fully cured, forms an impervious,
More informationApplication Guide for. MasterSeal Roof 3500 (MasterSeal M 820 Membrane)
Application Guide for MasterSeal Roof 3500 (MasterSeal M 820 Membrane) Roof slab crack-bridging waterproofing system February 2016 Page 1 of 7 1. Surface Preparation 1.1 Ensure the substrate has properly
More informationMETHOD STATEMENT SIKALASTIC -680 AP SIKA LIMITED (VIETNAM)
METHOD STATEMENT SIKALASTIC -680 AP SIKA LIMITED (VIETNAM) 1 SCOPE This method statement describes the step by step application of 1-component component, liquid applied, highly elastic polyurethane waterproofing
More informationApplication Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS
Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS CHECKLIST PRIOR TO THE INSTALLATION OF BACKSTOP NT - SMOOTH AND TEXTURE Project Conditions Maximum storage
More information80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces
80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces Section 09 01 90.92 COATING RESTORATION Sto Corp. 3800 Camp Creek
More informationSILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL
SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL Part 1. 1.1 Description General Conditions A. Scope of Work Provide all materials, labor and equipment required for the installation
More informationRapid Re-coat PU Modified Under-tile waterproof membrane.
Product Information Technical Data Sheet - December 2017 Rapid Re-coat PU Modified Under-tile waterproof membrane. DESCRIPTION Crommelin Rapid Re-coat PU Modified is a premium, heavy duty liquid applied
More information80648 StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80648 StoColor Acryl Plus Acrylic-Based, Vertical
More informationCentenary United Methodist Church January Code Improvements & North Entry Remodel Beatrice, Nebraska ADDENDUM NO. 1
Centenary United Methodist Church January 5. 2018 ADDENDUM NO. 1 The Architect/ Engineer issues this addendum, applicable to the above named project, to all known Contractors before receipt of proposal.
More informationTHE BRITE THING TO DO
REDUCING ENERGY CONSUMPTION IMPROVING AIR QUALITY THE BRITE THING TO DO BRITE-n-EZ Enhanced Coating Application Process on Black EPDM Roof Membrane BRITE-n-EZ EPDM Application Instructions CLEANING Remove
More informationTOPCOAT System Specifications Corrugated Transite Panels
TOPCOAT System Specifications Corrugated Transite Panels Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT System Specifications Corrugated Transite
More informationURETHANE. CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline
1 DG0049-A 052017 CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline URETHANE ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax: 972-554-3939
More informationSECTION MODIFIED BITUMINOUS SHEET WATERPROOFING
SECTION 07 13 52 MODIFIED BITUMINOUS SHEET WATERPROOFING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section
More informationAFM Anti-Fracture Membrane & AFM-WM Anti-Fracture Waterproofing Membrane Three-Part Specifications
AFM Anti-Fracture Membrane & AFM-WM Anti-Fracture Waterproofing Membrane Three-Part Specifications Protecto Wrap AFM Anti-Fracture Membrane and AFM - WM Anti-Fracture Waterproofing Membrane is a 40 mil
More informationSECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION
SECTION 093000 - SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION PART 1 - GENERAL This specification includes the sheet membrane used as waterproofing, vapor retarder, and crack isolation in conjunction
More informationPROTECTO DECK INSTALLATION INSTRUCTIONS
PROTECTO DECK INSTALLATION INSTRUCTIONS THE FOLLOWING MATERIALS ARE NEEDED TO COMPLETE THE PROTECTO DECK SYSTEM. Protecto Deck Protecto Deck is a cold applied, nominal 70 mil, self-adhering primary waterproofing
More informationERSYSTEMS OneStep Plus
1 DG0045-C 052017 CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline ERSYSTEMS OneStep Plus ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax:
More informationSECTION ANTI-FRACTURE MEMBRANE UNDERLAYMENT
SECTION 09 34 00 ANTI-FRACTURE MEMBRANE UNDERLAYMENT ************************************************************************************************************************ This guide specification has
More informationAQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters
AQUATITE Revision Date: september 2007 Description Bondall AquaTite is a grey, brushable, waterproofing coating that forms a flexible yet tough, seamless membrane. This single pack product exceeds the
More informationPERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960
STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary
More informationA Design Review of Waterproofing Codes
A Design Review of Waterproofing Codes Section 1807 of Chapter 18 of the International Building Code addresses waterproofing under the section title of Dampproofing and Waterproofing. The section defines
More informationSECTION SELF-ADHERING SHEET WATERPROOFING CCW-711
MANUFACTURER S GUIDE SPECIFICATIONS SECTION 071326 SELF-ADHERING SHEET WATERPROOFING CCW-711 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 605401 05.21.13 Carlisle, MiraDRAIN, MiraDRI
More informationCopolymer BEFORE. Copolymer DURING. Copolymer AFTER. (800) TRI-CHEM 3
Roof Repair Copolymer BEFORE Copolymer DURING Copolymer AFTER www.tri-chem.com (800) 456-6255 TRI-CHEM 3 TECHNICAL DATA SHEET TRI-MEMBRANE DESCRIPTION Tri-Membrane is an asphalt impregnated cotton membrane
More informationDesmopol Application Guide for Corrugated Asbestos Roofs
Substrate Preparation Existing Roof Inspect existing Asbestos sheeting. Thoroughly clean the sheets making it free from contaminants of moss and lichen including any grease and dust. Small cracks and damaged
More informationSection COATING RESTORATION
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80658R StoColor Texture - Coarse Textured Acrylic-Based,
More informationARDEX GUIDE SPECIFICATION ARDEX TRM Transportation Repair Mortar Fast-Setting Concrete Repair Mortar
ARDEX GUIDE SPECIFICATION ARDEX TRM Transportation Repair Mortar Fast-Setting Concrete Repair Mortar SECTION 03 92 50 PART 1 - GENERAL 1.1 SUMMARY A. This section includes Portland cement-based, microsilica-modified,
More informationMasterSeal HLM Liquid cold-applied elastomeric waterproofing membrane system
Liquid cold-applied elastomeric waterproofing membrane system DESCRIPTION MasterSeal HLM 5000 is a one-component, moisture-curing, bitumen-modified polyurethane elastomeric waterproofing membrane for exterior
More informationDesmopol Application Guide onto Ply/OSB Deck
Board and Trim Selection and Application For new roofs or when overboarding is necessary, we recommend using an 18mm Far Eastern WBP plywood or 18mm OSB3 in line with standard roofing practice. Before
More informationGUARANTEED ASPHALT LIMITED
GUARANTEED ASPHALT LIMITED GuaraTEC Installation Guide Installing our fully bonded hot melt system. 2016 Barratt Homes, Osiers Road Guaranteed Asphalt Limited 2 Mercury Way, London, SE14 5RR, 020 7277
More information80648R StoCoat Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80648R StoCoat Acryl Plus Acrylic-Based, Vertical
More informationPermaroof 500 Liquid Membrane application onto:- Corrugated asbestos roofs
Permaroof 500 Liquid Membrane application onto:- Corrugated asbestos roofs Permaroof UK Ltd www.permaroof.co.uk sales@permaroof.co.uk Tel: 0800 161 3722 Substrate preparation for existing asbestos roof
More informationBITUTHENE 3000 and BITUTHENE Low Temperature Below-Grade
BITUTHENE 3000 and BITUTHENE Low Temperature Below-Grade Self-adhesive, rubberized asphalt/polyethylene waterproofing membranes for basements and sub-structures Product Description BITUTHENE 3000 and BITUTHENE
More informationTOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets
TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications
More informationSECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING
SECTION 093000 - SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING PART 1 - GENERAL This specification includes the sheet membrane used for sound reduction, crack isolation
More informationSECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING
P.O. Box 599 - Mars, PA 16046 800-321-3337 SECTION 07555 COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including
More information80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80212R StoColor Lastic Acrylic-Based, Elastomeric
More informationData Sheet Eco-Smart Membrane WS M1
Water-based Acrylic WS M1 Elastomeric Waterproofing Membrane is a durable, multi-use, extremely durable acrylic coating. At an ideal wet film thickness of 10-14 mils per coat (8-10 mils dry film finish
More informationSection Pedestrian Traffic Coatings
Guide Specification MiraFlex II - For Concrete Surfaces Pedestrian Deck and Waterproofing System (Specification writer shall choose the most appropriate section that applies to a given scope of work, including
More informationRENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION
STUC-O-FLEX RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION 09 97 23 PART 1-GENERAL 1.00 SCOPE: Manufacturer's specifications containing the requirements necessary
More information