RAUPANEL DRY SYSTEM HIGH PERFORMANCE PANEL SYSTEM

Size: px
Start display at page:

Download "RAUPANEL DRY SYSTEM HIGH PERFORMANCE PANEL SYSTEM"

Transcription

1 RAUPANEL DRY SYSTEM HIGH PERFORMANCE PANEL SYSTEM Construction Automotive Industry

2 RAUPANEL SYSTEM OUTLINE - System Introduction - System advantages - System components - Installation techniques - Installing panels and pipes - Nail-down hardwood floors - Floating and glue-down floors - Carpet and vinyl floors - Tile floors - Over existing slab - RAUPANEL layouts - Routing pipe tails to manifolds - Installing EVERLOC couplings - Wall heating - Features and benefits summary - Comparison with other options - Performance testing - Installed cost comparisons REHAU 26-Mar-10 - Page 2

3 RAUPANEL SYSTEM INTRODUCTION - Aluminum is extruded with groove to hold 3/8 RAUPEX O 2 Barrier pipes with 270-degree contact - Total panel thickness is just 5/8 - Components allow for 6 or 8 o-c pipe spacing - Lightweight system, only 1.5 lbs/ft 2 - Combination of Aluminum and Plywood - λ of Aluminum = 230 Infra-red photograph of RAUPANEL system REHAU 26-Mar-10 - Page 3

4 RAUPANEL SYSTEM ADVANTAGES OF THE RAUPANEL ALUMINUM SYSTEM FOR THE DESIGNER - Ideal for kitchens, baths, entire house - May be used in floors, walls, ceilings - Efficient - Low-profile - Lightweight - High performance - Fast response time - Nighttime setback is an option - Solar gain problems are reduced - Easy to plan - Easy to install REHAU 26-Mar-10 - Page 4

5 RAUPANEL SYSTEM ADVANTAGES OF THE RAUPANEL ALUMINUM SYSTEM FOR THE CONTRACTOR - Higher efficiency thanks to reduced downward heat transfer and aluminum panels - May eliminate insulation under subfloors (over heated space below) - May eliminate double baseplates due to reduced floor thickness - No special equipment necessary (no wet thermal mass) - Faster response time than an overpour (lighter weight) - Suitable for both retrofit and new construction - No complicated scheduling and preparation - Fewer changes to overall construction - Eliminates other trade (thermal mass) - Design flexibility, easier to zone - Available when you want it - Everything is boxed - A complete system - Easy to carry - Low profile REHAU 26-Mar-10 - Page 5

6 RAUPANEL INSTALLATION COMPONENTS FIT TOGETHER AS A SYSTEM (1-2-3) 1. Lay out Return Bends and Furring Strips (for 8 spacing) 2. Drop Aluminum panels onto floor; align into notches with 8 Bends Note: Be sure that subfloor is clean before installation of panels REHAU 26-Mar-10 - Page 7

7 RAUPANEL INSTALLATION COMPONENTS FIT TOGETHER AS A SYSTEM (1-2-3) Note: Leave 1/16 to 1/8 gap between ends of panels to allow for possible house movement or shrinkage REHAU 26-Mar-10 - Page 8

8 RAUPANEL INSTALLATION COMPONENTS FIT TOGETHER AS A SYSTEM (1-2-3) 3. Pipe is walked into the groove; a rubber mallet may be needed to set it in Note: Be sure that panel grooves are clean before installation of pipes Note: No silicone is used to fill grooves. Pipes will not pop out when properly installed REHAU 26-Mar-10 - Page 10

9 RAUPANEL INSTALLATION DEBURR FIELD CUTS WITH DEBURRING TOOL IN THE GROOVE WARNING! Wear gloves and eye protection when handling pieces REHAU 26-Mar-10 - Page 11

10 RAUPANEL INSTALLATION THE NEXT STEPS: THE FOLLOWING INSTALLATION GUIDELINES APPLY TO VARIOUS FLOORING CHOICES 1. Nail-down hardwood flooring (over suspended subfloor) 2. Floating and glue-down flooring (over suspended subfloor) 3. Carpet and vinyl (over suspended subfloor) 4. Tile (over suspended subfloor) 5. Installations over concrete slabs Notes: - These are general guidelines for installation of RAUPANEL under common floor coverings - Certain floor coverings may have specific installation requirements which are not covered in this document - It is the responsibility of the installing heating contractor to work with other trades, including the installer of the finished floors, to ensure that the flooring manufacturer s requirements are adhered REHAU 26-Mar-10 - Page 12

11 RAUPANEL INSTALLATION NAIL-DOWN HARDWOOD FLOORS 1. Install panels and pipes following the first Steps Screw or nail Return Bends and Furring Strips to subfloor (use maximum 8 spacing between screws or nails) 3. Let the Aluminum panels float between plywood panels no need to screw these down 4. Install hardwood directly over RAUPANEL system (perpendicular in direction to panels) 5. Nail or staple hardwood boards into plywood components or through aluminum/into subfloor if necessary - Fasten boards every 6-8 It is recommended to use 8 spacing with furring strips when installing nail-down hardwood Note: Panel system may be loose and noisy until all hardwood is properly secured REHAU 26-Mar-10 - Page 13

12 RAUPANEL INSTALLATION NAIL-DOWN HARDWOOD FLOORS - Minimum 8 screws per Return Bend - Minimum 5 screws per Furring Strip - If subfloor is not even or has excessive deflection ( bounce ), then more fasteners may be required to prevent noise - Fasten as necessary - Screws: - Use fine-thread drywall screws or deck screws - Nails: - Use rough roofing nails or ringshank nails, not smooth nails, which could work loose - Nails must be long enough 8 spacing 8 spacing Note: Panel system may be loose and noisy until all hardwood is properly secured REHAU 26-Mar-10 - Page 15

13 RAUPANEL INSTALLATION NAIL-DOWN HARDWOOD FLOORS 6 SPACING INSTALLATION WITH HARDWOOD - If 6 spacing is necessary for heat load, this installation is possible - Aluminum panels and plywood pieces must be fastened to subfloor following instructions - Nail or staple hardwood flooring through aluminum panels into subfloor, every 6 - Must use 2 or longer cleats, nails or staples - It is recommended to use 5/8 or 1/2 thick hardwood to ensure most secure fastening 6 spacing REHAU 26-Mar-10 - Page 17

14 RAUPANEL INSTALLATION NAIL-DOWN HARDWOOD FLOORS 6 SPACING INSTALLATION WITH HARDWOOD - Must use 2 or longer cleats, nails or staples for good bite into subfloor - With 3/4 solid hardwood, a 2 fastener will have 5/8 length bite into subfloor - It is recommended to use 5/8 or 1/2 thick hardwood to ensure most secure fastening 2 Long REHAU 26-Mar-10 - Page 18

15 RAUPANEL INSTALLATION TYPICAL INSTALLATION WITH NAIL-DOWN HARDWOOD FLOORS REHAU 26-Mar-10 - Page 19

16 RAUPANEL INSTALLATION FLOATING AND GLUE-DOWN FLOORS 1. Install panels and pipes following the first Steps Screw or nail Return Bends and Furring Strips to subfloor (use maximum 8 spacing between screws or nails) 3. Fasten Aluminum panels 3 times per side - Total 6 per panel per 6-foot length 4. Install flooring as per manufacturer s recommendations - Avoid contacting glue onto pipes - Use 8 screws per Return Bend* - Use 5 screws per Furring Strip* - Use 6 screws per Aluminum Panel* *Per full length components Note: Always feel free to add extra fasteners if movement or noise is suspected REHAU 26-Mar-10 - Page 20

17 RAUPANEL LAYOUTS TYPICAL INSTALLATION WITH FLOATING FLOORS REHAU 26-Mar-10 - Page 22

18 RAUPANEL LAYOUTS TYPICAL INSTALLATION WITH FLOATING FLOORS REHAU 26-Mar-10 - Page 23

19 RAUPANEL INSTALLATION TILE FLOORS USING MORTAR BOARD AS ALTERNATIVE TO DIRECT PLACEMENT OF THINSET Sample cutaway floor: - 1/4 thick mortar board installed directly over RAUPANEL at 6 o-c spacing with maximum 8 grid spacing for screws - Tile placed on thinset over mortar board Note: When using panels at 6 o-c install screws at 6 o-c spacing also to avoid hitting pipes REHAU 26-Mar-10 - Page 27

20 RAUPANEL INSTALLATION TILE FLOORS USING MORTAR BOARD AS ALTERNATIVE TO DIRECT PLACEMENT OF THINSET Sample cutaway floor: - 1/4 thick mortar board installed directly over RAUPANEL at 6 o-c spacing - Tile placed on thinset over mortar board - Panels installed directly under shower pan for warmth REHAU 26-Mar-10 - Page 28

21 RAUPANEL INSTALLATION TYPICAL INSTALLATION WITH TILE FLOORS - 1/4 or 3/8 mortar board with 8 maximum grid spacing for screws REHAU 26-Mar-10 - Page 29

22 RAUPANEL INSTALLATION OVER EXISTING SLAB 1. If necessary, level floor with self-leveling thin-set 2. Cover existing slab (or above the leveling layer) with a poly or tar paper vapor barrier (not aluminum) to block possible moisture permeation 3. Install panels and pipes following the first Steps Depending on the flooring to be used, follow that typical installation technique: - When anchoring panel pieces, overlayment or mortar board, use proper fasteners for anchoring to concrete (ram-sets may work; masonry screws do work) - Be sure not to penetrate any existing pipes, cables, etc. in existing slab floor - Follow all safety precautions for using concrete fasteners REHAU 26-Mar-10 - Page 30

23 RAUPANEL INSTALLATION SEE REHAU REFERENCE DOCUMENTS CD - REHAU Reference Documents (CD) has Detailed Installation Drawings for installation techniques - Example: REHAU 26-Mar-10 - Page 31

24 RAUPANEL LAYOUTS HALLWAYS SHOULD BE FILLED WITH RAUPANEL TO AVOID COLD FLOORS, BUT THERE MAY NOT BE ENOUGH SPACE FOR ALL CIRCUIT TAILS IN HALLWAYS - Sometimes there are too many pipes to fit in a hallway, all within the panels (too many circuits to supply) - May have to install some pipes outside panels, or you may have to install some pipes through the subfloor to reach the manifold REHAU 26-Mar-10 - Page 38

25 ROUTING PIPE TAILS TO MANIFOLDS MACHINE OR ROUTER YOUR OWN PLYWOOD CUSTOM RETURNS REHAU 26-Mar-10 - Page 39

26 ROUTING PIPE TAILS TO MANIFOLDS DRILL 1 INCH HOLE AT 45-DEGREE ANGLE IN SUBFLOOR USE EVERLOC COUPLINGS TO EXTEND TAILS TO MANIFOLD REHAU 26-Mar-10 - Page 40

27 ROUTING PIPE TAILS TO MANIFOLDS DRILL 1 INCH HOLE AT 45-DEGREE ANGLE IN SUBFLOOR RUN PIPES THROUGH THE JOIST CAVITIES TO MANIFOLD - Note: These pipes are too close to the end of the panels. Not a good example REHAU 26-Mar-10 - Page 41

28 ROUTING PIPE TAILS TO MANIFOLDS DRILL 1 INCH HOLE AT 45-DEGREE ANGLE IN SUBFLOOR USE EVERLOC COUPLINGS TO EXTEND TAILS TO MANIFOLD REHAU 26-Mar-10 - Page 42

29 ROUTING PIPE TAILS TO MANIFOLDS DRILL 1 INCH HOLE AT 45-DEGREE ANGLE IN SUBFLOOR RUN PIPES THROUGH THE JOIST CAVITIES TO MANIFOLD REHAU 26-Mar-10 - Page 43

30 ROUTING PIPE TAILS TO MANIFOLDS JIGSAW A SLOT IN THE FLOOR RUN PIPES THROUGH THE JOIST CAVITIES TO MANIFOLD - Route pipes through floors and joist cavities to get to manifolds REHAU 26-Mar-10 - Page 44

31 ROUTING PIPE TAILS TO MANIFOLDS RUN ALL THE PIPES IN ONE NARROW AREA? NO! THIS METHOD IS NOT RECOMMENDED (HOT SPOT) - Avoid routing pipes to manifold on the subfloor go below REHAU 26-Mar-10 - Page 45

32 WALLS AND CEILINGS APPLICATIONS IN WALLS AND CEILINGS - Use panels for walls where supplemental heat is needed - Very nice in bathrooms, tub/shower walls, behind large mirrors, tubs Interior drywall REHAU 26-Mar-10 - Page 47

33 WALLS AND CEILINGS APPLICATIONS IN WALLS AND CEILINGS - Use panels for walls or ceilings where floor space is limited (bathrooms, kitchens, mudrooms) - May be the same circuit of pipe, same water temperature - Keep panels within 3 feet of floor to prevent future pipe punctures - Use furring strips on edges of studs above panels to make walls flush for drywall - Insulate behind panels at outside walls or ceilings REHAU 26-Mar-10 - Page 48

34 WALLS AND CEILINGS INSTALLED IN A WALL SURROUNDING A SHOWER Sample cutaway wall: - 1/4 thick tileboard board installed directly over RAUPANEL at 8 o-c spacing - Tile is placed on thinset over tileboard - Furring strips are used on stud edges above panels to flush out the walls before tileboard installation REHAU 26-Mar-10 - Page 49

35 WALLS AND CEILINGS INSTALLED IN A WALL SURROUNDING A SHOWER Sample cutaway wall: - 1/4 thick tileboard board installed directly over RAUPANEL at 8 o-c spacing - Tile placed on thinset over tileboard - Great for warming tub/shower area - Adds supplemental heat to entire bathroom, kitchen or mudroom REHAU 26-Mar-10 - Page 50

36 RELATIVE OUTPUT OF RFH SYSTEMS VTECH STUDY RESULTS: COMPARISON OF FLOOR OUTPUT WITH 110 F INPUT WATER TEMPERATURE Output with 110 F Input Water Temperature Position System Output BTU/hr-ft RAUPANEL 6" spacing RAUPANEL 8" spacing MDF board with foil face, 8" spacing (ThermalBoard) Expanded PS base with aluminum plates, 6" spacing (Roth) Gypsum cement overpour 1 1/2" thick, 8" spacing Joist Space with heavy gauge extruded aluminum plates, 8" spacing (Thin-Fin) Thin plywood with aluminum backing, 7" spacing (Quik-Trak) Structural plywood with aluminum facing, 12" spacing (WarmBoard) Joist Space, no heat transfer plates, 8" spacing Joist Space, aluminum louvers in air cavities, 24" spacing (Ultra-Fin) REHAU 26-Mar-10 - Page 60

37 RELATIVE OUTPUT OF RFH SYSTEMS VTECH STUDY RESULTS: COMPARISON OF FLOOR OUTPUT WITH 110 F INPUT WATER TEMPERATURE Radiant Floor Heating System Relative Output Output, BTU/hr per Square Foot with 1/4" thick plywood covering RAUPANEL 6" spacing RAUPANEL 8" spacing MDF board w ith fo il fa c e, 8" spacing Expanded PS base with alum imum plates, 6" G ypsum cement overpour, 1 1/2" thick, 8" spacing Joist Space with extruded aluminum plates, 8" Thin plywood with alum inum backing, 7" Structural plywood with alum inum fa c ing, 1 2 " Joist Space, no heat transfer plates, 8" Joist Space, aluminum louvers in air cavities, Commercial Radiant Floor Heating Systems Tested, 110 F Water Temperature REHAU 26-Mar-10 - Page 62

38 RAUPANEL ADVANTAGES HIGHER PUMPING EFFICIENCY (LOWER HEADLOSS) RAUPANEL uses 3/8 PEXa pipe: - 3/8 RAUPEX pipe has 1/3 the headloss of 5/16 PEX pipe - Smaller pumps can be used - Longer circuits are possible - Lower Delta-T across manifold Example: 0.4 GPM, 250 ft circuit designed to deliver 4,000 BTU/hr - 5/16 hepex: 18.6 ft headloss - 3/8 RAUPEX: 6.3 ft headloss Head Loss (feet of head) with 120 o F (49 o C) Water 5/16" (10 mm) PEX** Flow Rate Loss 100 foot 150 foot 200 foot 250 foot GPM per foot* circuit circuit circuit circuit Head Loss (feet of head) with 120 o F (49 o C) Water 3/8" RAUPEX Pipe Flow Rate Velocity 100 foot 150 foot 200 foot 250 foot GPM ft/sec circuit circuit circuit circuit REHAU 26-Mar-10 - Page 63

39 RAUPANEL DRY SYSTEM HIGH PERFORMANCE PANEL SYSTEM Construction Automotive Industry

RAUPANEL RADIANT HEATING SYSTEMS HEAT TRANSFER PANEL PRODUCT INSTRUCTIONS. Construction Automotive Industry

RAUPANEL RADIANT HEATING SYSTEMS HEAT TRANSFER PANEL PRODUCT INSTRUCTIONS.  Construction Automotive Industry RAUPANEL RADIANT HEATING SYSTEMS HEAT TRANSFER PANEL PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide provides technical instruction regarding the installation of RAUPANEL

More information

ronblank.com to receive credit Lance MacNevin REHAU Inc Edwards Ferry Rd. Leesburg, VA

ronblank.com to receive credit Lance MacNevin REHAU Inc Edwards Ferry Rd. Leesburg, VA Ron Blank and Associates, Inc. 2010 Please note: you will need to complete the conclusion quiz online at ronblank.com to receive credit SUSTAINABLE BUILDING TECHNOLOGY REHAU s sustainable building technology

More information

RAUPANEL System. Installation Guide

RAUPANEL System. Installation Guide RAUPANEL System Installation Guide Table of Contents 1.0 Introduction 1 2.0 System Components 2 2.1 RAUPANELs 2 2.2 Return Bends 2 2.3 Furring Strips 2 2.4 3/8" RAUPEX O 2 Barrier Pipe 2 3.0 Tools 3 3.1

More information

RAUBOARD RADIANT HEATING SYSTEMS HEAT TRANSFER PANEL PRODUCT INSTRUCTION. Construction Automotive Industry

RAUBOARD RADIANT HEATING SYSTEMS HEAT TRANSFER PANEL PRODUCT INSTRUCTION.  Construction Automotive Industry RAUBOARD RADIANT HEATING SYSTEMS HEAT TRANSFER PANEL PRODUCT INSTRUCTION www.rehau.com Construction Automotive Industry SCOPE This technical information provides instruction regarding the installation

More information

RAUPANEL Radiant Heating Systems. Installation Guide

RAUPANEL Radiant Heating Systems. Installation Guide RAUPANEL Radiant Heating Systems Installation Guide 855.625 Table of Contents 1.0 Introduction 1 2.0 System Components 2 2.1 RAUPANELs 2 2.2 Return Bends 2 2.3 Furring Strips 2 2.4 3/8" RAUPEX O 2 Barrier

More information

Quik Trak design and installation manual

Quik Trak design and installation manual Quik Trak design and installation manual Table of contents Quik Trak design and installation manual Uponor Quik Trak overview.... 1 Installation tools... 1 Prepping the panel area.... 1 Panel calculations....

More information

RADIANT PANEL SYSTEM PLANNING & INSTALLATION. Roth Radiant Heating Systems

RADIANT PANEL SYSTEM PLANNING & INSTALLATION. Roth Radiant Heating Systems RADIANT PANEL SYSTEM PLANNING & INSTALLATION Roth Radiant Heating Systems INTRODUCTION The Roth Radiant Panel System was developed for the wood frame houses of the North American and Scandinavian markets.

More information

INSTALLING MrPEX TUBING

INSTALLING MrPEX TUBING INSTALLING MrPEX TUBING INSTALLING THE TUBING Now that you are ready to install the tubing, take a minute to decide which loop to start with first. Typically, working your way from left to right as you

More information

RADIANT HEATING SYSTEMS QUIK TRAK DESIGN AND INSTALLATION MANUAL. Quik Trak Design and Installation Manual

RADIANT HEATING SYSTEMS QUIK TRAK DESIGN AND INSTALLATION MANUAL. Quik Trak Design and Installation Manual RADIANT HEATING SYSTEMS QUIK TRAK DESIGN AND INSTALLATION MANUAL Quik Trak Design and Installation Manual Table of Contents Uponor Quik Trak 1 Quik Trak Calculations 2 Installation Methods 3 Quik Trak

More information

SubRay Radiant. Header Sticks Sleepers Corner Sweeps Grippers Tape Conduction Layer C-Covers. Subfloor System

SubRay Radiant. Header Sticks Sleepers Corner Sweeps Grippers Tape Conduction Layer C-Covers. Subfloor System Radiant s s Corner Sweeps Grippers Tape Conduction Layer C-Covers Subfloor System 56 Anatomy of the Radiant System Holds radiant pipe at each end of the room on 8" centers. 6" wide and installed 2" apart.

More information

AquaHeat Installation Guide

AquaHeat Installation Guide Installation Guide AquaHeat Dry Above A systems approach integrating established and emerging technologies Preface System Design and Installation The Mains PEX pipe mains are recommended to reduce labor

More information

PEX Plates for Underfloor Applications

PEX Plates for Underfloor Applications Installation Bulletin: PEX Plates for Underfloor Applications Release Date: October 2001 3131 W. Chestnut Expressway Springfield, MO 65802 ph: 417.864.6108 fax: 417.864.8161 www.wattsradiant.com Watts

More information

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360. HARDWOOD FLOOR Read First These suggestions represent generally accepted procedures for successful installation of Maxxon Products. These instructions may be followed, modified or rejected by the owner,

More information

ThermoFin U SPEC - DATA

ThermoFin U SPEC - DATA ThermoFin U Patent 5,454,428 Canada Patent 2,158,302 MADE IN USA ThermoFin U is a versatile extruded aluminum heat transfer plate that can be used in several radiant panel heating applications including

More information

L. W. Mountain, Inc. Floating Glue Installation Instructions *For use with engineered floors only*

L. W. Mountain, Inc. Floating Glue Installation Instructions *For use with engineered floors only* L. W. Mountain, Inc. Floating Glue Installation Instructions *For use with engineered floors only* Inspect the job site carefully before you begin the installation. Some conditions require specific installation

More information

PLYWOOD FLOATING FLOOR

PLYWOOD FLOATING FLOOR PLYWOOD FLOATING FLOOR Read First These suggestions represent generally accepted procedures for successful installation of Enka Building Products. These instructions may be followed, modified, or rejected

More information

1. What are the benefits of Decorative Wall Panels? 2. Where can these decorative panels are used? 3. Are the panels waterproof?

1. What are the benefits of Decorative Wall Panels? 2. Where can these decorative panels are used? 3. Are the panels waterproof? 1. What are the benefits of Decorative Wall Panels? Decorative Wall Panels are made from precision extruded PVC and decorated with unique designs ranging from marble, onyx to wood grain patterns. Other

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

Installation Instructions

Installation Instructions Installation Instructions FW Cable Silicone Jacketed Floor Warming Cable Warning: Delta-Therm Silicone Jacketed Cable must be installed by a qualified installer. All assembly, installation, and test instructions

More information

INSTALLATION METHODS ENGINEERED FLOORING FLOATING, GLUED-DOWN OR NAILED INSTALLATION METHODS

INSTALLATION METHODS ENGINEERED FLOORING FLOATING, GLUED-DOWN OR NAILED INSTALLATION METHODS INSTALLATION METHODS ENGINEERED FLOORING FLOATING, GLUED-DOWN OR NAILED INSTALLATION METHODS BEFORE THE INSTALLATION ENGINEERED HARDWOOD FLOOR INSTALLATION: It is important to account for a 5% surplus

More information

Expanded AmDry Installation Guide

Expanded AmDry Installation Guide Expanded Tools Required: Tape measure Utility Knife Straight edge Rubber mallet Circular saw with plywood blade Pull or pry bar 1/2 spacers Pencil / marker Tapping block (made from a piece of 2 x 4 ) Getting

More information

MAKING IT STICK: Nails and screws, adhesives and compounds... today contractors have a wide variety of choices.

MAKING IT STICK: Nails and screws, adhesives and compounds... today contractors have a wide variety of choices. MAKING IT STICK: Fasteners & Adhesives Walls hold up the building but what holds up the walls? Today contractors have a wide variety of fasteners and adhesives from which to choose, according to the needs

More information

Installation and Planning Guide

Installation and Planning Guide Installation and Planning Guide www.dricore.com help@dricore.com or call 1-866-976-6374 Weekdays 9am-5pm EST CONTENTS Why DRIcore... 1 How To Use This Guide... 1 Before You Begin Checklist... 2 Important

More information

R-Matte Plus-3: Insulation for the Building Envelope

R-Matte Plus-3: Insulation for the Building Envelope Attic and Crawl Space Applications R-Matte Plus-3 may be applied to the interior face of stud walls or roof rafters within attics and crawl spaces to provide a layer of continuous insulation (ci). Simply

More information

Existing Floors & Low Profile Systems

Existing Floors & Low Profile Systems Existing Floors & Low Profile Systems Existing Floors & Low Profile Systems Underfloor heating that goes over the floor For existing solid or timber deck floors - Polypipe s unique Overlay underfloor heating

More information

Installation Guide. Floor heating. Vodoley CO

Installation Guide. Floor heating. Vodoley CO Installation Guide Floor heating Vodoley CO Bulgaria, 5000 V.Tarnovo, 7 Ionovka str., Phone/Fax: +359 62 649652 E-mail: floorheating@vodoley91.com, vodoley98@hotmail.com www.vodoley91.com 2 Vodoley Co.

More information

Metal Web Floor System

Metal Web Floor System Metal Web Floor System Contents Contents Introduction and benefits 3 easi-joist definitions 4 easi-joist webs 5-6 Mechanical services 7 Loading and design 8 Floor stiffness 9 Internal non-loadbearing wall

More information

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE USG Tile & Flooring Solutions Lightweight cement board Easy to cut and fasten Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE USG DUROCK BRAND CEMENT BOARD For more than 30 years,

More information

REHAU RADIANT HEATING SYSTEMS INSTALLATION GUIDE. Construction Automotive Industry.

REHAU RADIANT HEATING SYSTEMS INSTALLATION GUIDE. Construction Automotive Industry. REHAU RADIANT HEATING SYSTEMS INSTALLATION GUIDE www.rehau.com Construction Automotive Industry Table of Contents 1. Scope................................................... 3 2. Installation Considerations...................................

More information

1 PVC or ABS drain with strainer

1 PVC or ABS drain with strainer Patents Pending ProBase II Single-Slope Shower Base and Kit CONTENTS 1. General Information...1 2. Materials...1 3. Planning...2 4. Preparation...3 5. Layout...3 6. Install Base and Shims...4 7. Install

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS About PROTECH Luxury Vinyl Planks 8.7mm WPC Click Lock Contemporary Collection features patented interlocking planks for easy installation and is installed as a glue less floating floor. The interlocking

More information

TYPICAL BEARING WALL FRAMING

TYPICAL BEARING WALL FRAMING BASIC WOOD FRAMING City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code,

More information

Rev. 08 9/15 Please Read Disclaimers:

Rev. 08 9/15 Please Read Disclaimers: NuPoly panels Guidelines 6006.NP Rev. 08 9/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to help prevent any problems

More information

VESDURA ENGINEERED VINYL PLANK INSTALLATION GUIDE

VESDURA ENGINEERED VINYL PLANK INSTALLATION GUIDE VESDURA ENGINEERED VINYL PLANK INSTALLATION GUIDE Vesdura Engineered Vinyl Plank features the patented Unilin interlocking planks for easy installation and is installed as a glueless floating floor. The

More information

Information Kit. Table Of Contents. Radiant Floor Tubing Comparison Page 1. Butt Weld Verses Overlap Weld Page 2

Information Kit. Table Of Contents. Radiant Floor Tubing Comparison Page 1. Butt Weld Verses Overlap Weld Page 2 Information Kit Table Of Contents Radiant Floor Tubing Comparison Page 1 Butt Weld Verses Overlap Weld Page 2 Insulation and Vapor Barrier Information Page 3-5 Location of Tubing in Concrete Page 5-6 Lightweight

More information

Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6

Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6 Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6 Installing a Subfloor Over Concrete 27 24 National Wood Flooring

More information

Installation Guidelines: Magnolia

Installation Guidelines: Magnolia Installation Guidelines: Magnolia 3/8 Engineered Hardwood Staple Down Installation ATTENTION Inspect ALL materials carefully BEFORE Warranties DO NOT cover materials with visible defects once they are

More information

APPLICATION FOR FINISHED BASEMENT PERMIT

APPLICATION FOR FINISHED BASEMENT PERMIT APPLICATION FOR FINISHED BASEMENT PERMIT REAL ESTATE TAX I.D. #: - - _ - _ 7607 W College Drive Ph: (708) 361-1804 Fax: (708) 923-7112 building@palosheights.org APPLICANTS: COMPLETE ALL ITEMS AND SUBMIT

More information

Accent Floor Heating. Tmat System Installation Manual. Floor heating system

Accent Floor Heating. Tmat System Installation Manual. Floor heating system Tmat System Installation Manual Floor heating system Contents Safeguards and Warnings 1 1 General Information 1 1.1 Use of the Manual 1 1.2 Safety Guidelines 1 1.3 Remember to measure resistance 2 1.4

More information

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING WARNING Prior to installation, please ensure that the product received is the correct style and color as well as to the customer s satisfaction.

More information

PermaBase BRAND Cement Board

PermaBase BRAND Cement Board PermaBase BRAND Cement Board Behind Every Great Finish is a Strong Base! PermaBase BRAND Cement Board A Ceramic tile s best friend. Ceramic tile is only as good as the base it sits on. And the best base

More information

Triton BK Backer Board & Tile Underlayment

Triton BK Backer Board & Tile Underlayment 1 Backer Board & Tile Underlayment Lightest Cementitious Backer Board High strength cement technology Free of Crystalline Silica, VOCs, and harsh chemicals Easy to score and snap, fasten, and install Description

More information

WE International, Inc.

WE International, Inc. M E E T Y O U R R O U N D T H E Steel Frame Building Roof Application - Drape Method Ideal insulation for steel frame building application Quick and easy to install Provides reflective insulation for radiant

More information

OVERLAY TM. Under floor heating that fits over existing floors

OVERLAY TM. Under floor heating that fits over existing floors OVERLAY TM Under floor heating that fits over existing floors Overlay TM is a unique low profile floor heating system ideal for both renovation and new build projects. Installed over the existing floor

More information

INSTALLATION MANUAL U.S PATENT #6,533,185 and patents pending. HigH performance cost-effective contractor friendly

INSTALLATION MANUAL U.S PATENT #6,533,185 and patents pending. HigH performance cost-effective contractor friendly ecowarm RADIANT BOARD aluminum laminated radiant floor system HigH performance cost-effective contractor friendly INSTALLATION MANUAL 2018 866-341-1854 TOLL-FREE www.ecowarmradiantheat.com U.S PATENT #6,533,185

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS VINYL PLANKS 6.5MM HDPC CLICK LOCK REVIVAL COLLECTION General Information 1. Flooring should be transported and stored in a neatly stacked fashion on a smooth flat surface. Be sure to inspect the run numbers/production

More information

Please read and review installation instructions completely before proceeding with the actual installation.

Please read and review installation instructions completely before proceeding with the actual installation. INSTALLATION INSTRUCTIONS Important / Read First Please read and review installation instructions completely before proceeding with the actual installation. Owner / Installer responsibility The installer

More information

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING WARNING Prior to installation, please ensure that the product received is the correct style and color as well as to the customer s

More information

Product Installation Manual

Product Installation Manual HeatPly Inc. Installation Manual Product Installation Manual Table of Contents INTRODUCTION:... 3 Easy to Install... 3 Local Codes and Regulations... 3 Crawl Space Requirements... 3 Subfloor Requirements...

More information

DESIGN and INSTALLATION MANUAL 2018

DESIGN and INSTALLATION MANUAL 2018 RADIANT BOARD ecowarmtm Aluminum Laminated Radiant Floor System HIGH PERFORMANCE COST-EFFECTIVE CONTRACTOR FRIENDLY 866-341-1854 TOLL-FREE U.S. PATENT #6,533,185 and patents pending DESIGN and MANUAL 2018

More information

Typical Installation Details

Typical Installation Details Installation Manual DRAIN SET AT ENTRY TO CURBLESS SHOWER ON CONCRETE SUBFLOOR Typical Installation Details Office : 970.668.0805 or 866.998.6685 Fax : 866.357.8502 P.O. Box 1358 Frisco, Colorado 80443

More information

J.J. Haines & Co., Inc.

J.J. Haines & Co., Inc. Subfloor Guide for Hardwood Ask any quality wood flooring contractor, and he'll tell you that your hardwood installation is only as good as the subfloor you're installing over. Before the wood is delivered

More information

Floor SoundprooFIng Made Simple

Floor SoundprooFIng Made Simple Floor SoundprooFIng Made Simple THE PERFECT SOLUTION FOR Luxury RENOVATION PROJECTS Any Finished Floor Double Plywood Floated Subfloor Original Subfloor Insulation Wood Joists Any Finished Floor Double

More information

Chapter 14 - Air Sealing

Chapter 14 - Air Sealing Chapter 14 - Air Sealing Contents Chapter 14 - Air Sealing... 14-1 Pre-Mechanicals Activities... 14-3 Insulate Bathtub Enclosures... 14-3 Insulate Double Walls and Chases... 14-3 Pre-Inspection Checklist...

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

ASC ACOUSTIC. ASC IsoDamp Guide to High Performance Soundproofing. Table of Contents SCIENCES CORPORATION. Introduction Page 2

ASC ACOUSTIC. ASC IsoDamp Guide to High Performance Soundproofing. Table of Contents SCIENCES CORPORATION. Introduction Page 2 ASC IsoDamp Guide to High Performance Soundproofing Table of Contents Introduction Page 2 Ceiling Installation Page 3 Perimeter Gasket Page 4 Resilient Channel Page 5 Installing First Layer of Sheetrock

More information

Wellmade HDPC Engineered Vinyl Plank/Tile Installation Guide

Wellmade HDPC Engineered Vinyl Plank/Tile Installation Guide Wellmade HDPC Engineered Vinyl Plank/Tile Installation Guide Wellmade HDPC is a High Density Plastic Composite (HDPC) flooring with patent pending technology, HDPC is an engineered vinyl plank/tile flooring

More information

Install Instructions. Helix Z1. Important Information. Important:

Install Instructions. Helix Z1. Important Information. Important: Congratulations, you have just purchased the highest quality entrance mat available. Proper installation is necessary to ensure that your warranty will be honored by Impact Specialties. Important Information

More information

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of

More information

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE: SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance

More information

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only Installation Method (Existing Walls) 1. ESP Low-E Housewrap is installed over exterior wall sheathing, make sure reflective side faces out: foil flange faces down. 2. Determine width of ESP Low-E HouseWrap

More information

Please Note: PhoneStar was previously branded as Phonewell

Please Note: PhoneStar was previously branded as Phonewell Soundproofing Floors Timber Joist or Concrete Floors Installation Instructions Acoustic Insulation Please Note: was previously branded as Phonewell There are two options to achieve noise reduction through

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS VINYL PLANKS 6.5MM HDPC CLICK LOCK PERSPECTIVE COLLECTION General Information 1. Flooring should be transported and stored in a neatly stacked fashion on a smooth flat surface. Be sure to Inspect the run

More information

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING:

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING: GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 is a reflective insulation composed of the reinforced aluminum facers on a Polyethylene foam core. ESD 5 can be installed in Roof assemblies, Floors and walls.

More information

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING:

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING: GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 is a reflective insulation composed of the reinforced aluminum facers on a Polyethylene foam core. ESD 5 can be installed in Roof assemblies, Floors and walls.

More information

FirstEnergy Program Overview

FirstEnergy Program Overview FirstEnergy Program Overview Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS VINYL PLANKS 4MM HDPC CLICK LOCK FORESIGHT COLLECTION General Information 1. Flooring should be transported and stored in a neatly stacked fashion on a smooth flat surface. Be sure to Inspect the run numbers/production

More information

ADDENDUM A CONSTRUCTION SPECIFICATIONS

ADDENDUM A CONSTRUCTION SPECIFICATIONS ADDENDUM A Description of Improvements: CONSTRUCTION SPECIFICATIONS The Improvements shall consist of constructing an approximate square foot single-family residence including car garage on the real property

More information

FILE / INSTALL TILE ON WOOD SUBFLOOR DOWNLOAD

FILE / INSTALL TILE ON WOOD SUBFLOOR DOWNLOAD 28 June, 2018 FILE / INSTALL TILE ON WOOD SUBFLOOR DOWNLOAD Document Filetype: PDF 517.82 KB 0 FILE / INSTALL TILE ON WOOD SUBFLOOR DOWNLOAD A cement backer subfloor can be used underneath stone or ceramic

More information

10 Steps to Save Energy in Your House

10 Steps to Save Energy in Your House 10 Steps to Save Energy in Your House Sealing and insulating your home is one of the most cost-effective ways to make your home more comfortable and energy efficient. You can do it yourself. In this chapter,

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

PDF / HOW TO INSTALL TILE FLOOR OVER WOOD SUBFLOOR

PDF / HOW TO INSTALL TILE FLOOR OVER WOOD SUBFLOOR 21 May, 2018 PDF / HOW TO INSTALL TILE FLOOR OVER WOOD SUBFLOOR Document Filetype: PDF 109.93 KB 0 PDF / HOW TO INSTALL TILE FLOOR OVER WOOD SUBFLOOR This is true of vinyl tile installation over any. Install

More information

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights 1 Exam Prep Application and Finishing of Gypsum Board GA-216-2013 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2013 Application and Finishing of Gypsum Panel Products. Each

More information

Carpentry. The following describes the scope and sequence of instruction for Carpentry.

Carpentry. The following describes the scope and sequence of instruction for Carpentry. Carpentry The Montgomery County Students Construction Trades Foundation, Inc has developed a comprehensive construction technology program designed to prepare students for a rewarding career in the construction

More information

REHAU MONTANA ECOSMART HOUSE PROJECT Bozeman, MT RMEH 04 Test Report

REHAU MONTANA ECOSMART HOUSE PROJECT Bozeman, MT RMEH 04 Test Report REHAU MONTANA ECOSMART HOUSE PROJECT Bozeman, MT RMEH 04 Test Report Evaluation of Pickup Response Time of Radiant Floor Using Different Water Supply Temperatures F. Javier Alvarez, LEED GA Kevin Amende,

More information

ATTICS. Use: PRODEX TOTAL INSULATION Foil-Foam-Foil (FfmF), Foil-Bubble-Foil (FBF), Foil-Fiberglass-Vinyl (FfgV), Foil-Foil (FF)

ATTICS. Use: PRODEX TOTAL INSULATION Foil-Foam-Foil (FfmF), Foil-Bubble-Foil (FBF), Foil-Fiberglass-Vinyl (FfgV), Foil-Foil (FF) ATTICS Use: PRODEX TOTAL INSULATION Foil-Foam-Foil (FfmF), Foil-Bubble-Foil (FBF), Foil-Fiberglass-Vinyl (FfgV), Foil-Foil (FF). Installation Method: 1. Starting at the eave and working upwards, roll out

More information

FLOORING SPECIFICATIONS FOR 1744 JOHNSON ST.

FLOORING SPECIFICATIONS FOR 1744 JOHNSON ST. 30 Greenway, NW Suite 11 Glen Burnie, Maryland 21061 tel 410.528.8899 fax 410.558.6312 www.gbalternatives.com FLOORING SPECIFICATIONS FOR 1744 JOHNSON ST. VERSION 1 _ 02-07-2007 30 Greenway, NW Suite 11

More information

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIPS Installation Manual Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIP SPECIFICATIONS Width...1.00 inch Height...1.06 inch Length...3.86

More information

Super-Compact Ceiling Hanger Model KSCH Patent Pending Ceiling Isolation Theory: Resiliently suspended ceiling systems are designed to minimize floor impact noise and airborne sound transmissions through

More information

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights 1 Exam Prep Application and Finishing of Gypsum Board GA-216-2016 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2016 Application and Finishing of Gypsum Panel Products. Each

More information

PROVEN, RELIABLE SOUND CONTROL COST EFFECTIVE SOLUTION FOR WALLS/CEILINGS MULTI-FAMILY, SINGLE FAMILY, HOME THEATER

PROVEN, RELIABLE SOUND CONTROL COST EFFECTIVE SOLUTION FOR WALLS/CEILINGS MULTI-FAMILY, SINGLE FAMILY, HOME THEATER SOUND ISOLATION SOLUTIONS PROVEN, RELIABLE SOUND CONTROL COST EFFECTIVE SOLUTION FOR WALLS/CEILINGS MULTI-FAMILY, SINGLE FAMILY, HOME THEATER Model A237R Thermoplastic rubber with no metal washer or ferrule;

More information

Rev. 07 8/15 Please Read Disclaimers:

Rev. 07 8/15 Please Read Disclaimers: FiberCorr panels Guidelines 6005.FC Rev. 07 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to help prevent any problems

More information

ThermaSteel Corporation ASSEMBLY MANUAL

ThermaSteel Corporation ASSEMBLY MANUAL ThermaSteel Corporation ASSEMBLY MANUAL TABLE OF CONTENTS 1- INTRODUCTION 1.1 THERMASTEEL TM WALL PANELS 1.2 Drawing and Element Numbers 2- ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation of Foundation

More information

INSTALLATION INSTRUCTIONS LAMINATE

INSTALLATION INSTRUCTIONS LAMINATE INSTALLATION INSTRUCTIONS LAMINATE DROP LOCK GENERAL INSTRUCTIONS FOR LAMINATE HARDWOOD FLOORING ACCLIMATION Acclimation is a recommended procedure prior to installation of laminate flooring either on

More information

YOUR LITE-DECK SECTIONS

YOUR LITE-DECK SECTIONS General Information Warning - Serious injury or death may result from safety hazards caused by improper use or installation. When in doubt about proper use or installation of Lite-Deck, immediately contact

More information

TOP CAP Snaps into bottom track Aluminum - trimmed to length. RAMPS Covered by carpet ABS plastic and MDF QUESTIONS? CALL US AT !

TOP CAP Snaps into bottom track Aluminum - trimmed to length. RAMPS Covered by carpet ABS plastic and MDF QUESTIONS? CALL US AT ! IN-CARPET WIREWAY INSTALLATION GUIDE 2.7 These components are typical for each wireway installation: WALL BASE TRIM Finishes cable opening at wall BOTTOM TRACK Screws to concrete Aluminum - trimmed to

More information

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction Walls And Ceilings Single- And Double-Layer Construction 09 9 00/NGC Single-Layer Construction The single-layer construction system consists of a single layer of Gold Bond brand Gypsum Board applied to

More information

- Inbound/Outbound window placement - Window buck & air sealing - Weep holes IN THE WOODS DETAILS - WINDOW SILL

- Inbound/Outbound window placement - Window buck & air sealing - Weep holes IN THE WOODS DETAILS - WINDOW SILL - Inbound/Outbound window placement - Window buck & air sealing - Weep holes IN THE WOODS DETAILS - WINDOW SILL PRE-EXISTING SITE Program: Traditional farmhouse Single level living potential Garage connection

More information

Thermasheath-XP. Insulation for Exposed Use

Thermasheath-XP. Insulation for Exposed Use Insulation for Exposed Use PRODUCT DESCRIPTION Rmax Thermasheath-XP is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam bonded to durable, embossed

More information

ECOWARM PLUS INSTALLATION MANUAL ENVIRONMENTALLY FRIENDLY RADIANT FLOOR HEATING SYSTEMS. OFFERED BY:

ECOWARM PLUS INSTALLATION MANUAL ENVIRONMENTALLY FRIENDLY RADIANT FLOOR HEATING SYSTEMS. OFFERED BY: ECOWARM PLUS R FSC Certified Radiant Board INSTALLATION MANUAL ENVIRONMENTALLY FRIENDLY RADIANT FLOOR HEATING SYSTEMS OFFERED BY: www.ecowarm.us 503-266-1615 U.S. Patent # 6,533,185 and Patents Pending

More information

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Thank you for purchasing the Genesis Dura-Max Brick Panel system for your project. The system allows you to have the look

More information

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION DRAINAGE SOLUTIONS SINCE 1908 PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION PROVEN PERFORMANCE ARMTEC.COM

More information

Standard Practice for Installing Sound-Isolating Lightweight Partitions 1

Standard Practice for Installing Sound-Isolating Lightweight Partitions 1 Designation: E 497 99 Standard Practice for Installing Sound-Isolating Lightweight Partitions 1 This standard is issued under the fixed designation E 497; the number immediately following the designation

More information

Wooden suspended floors

Wooden suspended floors UPONOR PEX PRODUCTION UNDERFLOOR HEATING WOODEN SUSPENDED FLOORS Wooden suspended floors 08 2006 Uponor Underfloor Heating in Wooden suspended floors Wooden suspended floors The term suspended floors in

More information

Installation Guide Mesh Floor Heating System

Installation Guide Mesh Floor Heating System Installation Guide Mesh Floor Heating System WarmFeet Tel: 1-450-482-1919 Toll Free: 1-866-994-4664 Fax: 1-450-482-1920 www.warmfeet.ca 1 This guide describes the WarmFeet Mesh Floor Heating System how

More information

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507) Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed

More information

For Ideal Living. Installation Instruction. Maintenance Instruction. Product Warranty.

For Ideal Living. Installation Instruction. Maintenance Instruction. Product Warranty. For Ideal Living Installation Instruction Maintenance Instruction Product Warranty www.idealwood.ca Part 1, Pre-installation: A, Responsibility of customers and installers: It is a highly recommendation

More information