Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

Size: px
Start display at page:

Download "Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options"

Transcription

1 *lum ngle 50x50x1.6mm min. with 20mm lum fixing bar to mechanically secure membrane Enviroclad Waterproofing Membrane Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from B *lum ngle 50x50x1.6mm with SMT076V Laptape to seal Enviroclad to drip-edge C * Refer NZBC Clause E2 Table 21 for Metal ngle compatibility with CC treated timber. If required use separation layer between materials TPO coated Galv ngle 50x50x.55mm Enviroclad can be welded to drip-edge for a secure termination EC01 Enviroclad Drip Edge Specify from the above three options EC01

2 230mm 230mm Clamped Drain or Overflow SDM049 80mm flowrate 3.2Lts/sec 100mm flowrate 5 Lts/sec Outlet Overflow Note: 1/ Overflow to match outlet capacity. 2/ Overflow to be plumbed independent of stormwater, through soffit or exterior wall EC02 Enviroclad Dropper Outlet and Overflow EC02

3 It is Roofspecs view that Internal Gutters can be eliminated in most cases. In doing so you may Reduce overall heights or increase roof falls while reducing risk and detail. To find out more contact Roofspec Technical *E2/S1 Min. falls for gutters = 1:100 40mm Weld Enviroclad Waterproofing Membrane 40mm Weld Minimum 5mm Radius to all external edges SDM049 Drain or Overflow 80/100mm Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from * pply cut edge sealant to all cut edges of reinforced membrane. * No fillets required with Enviroclad. EC03 Enviroclad Internal Gutter EC03

4 Optional Head-flashing to prevent water over fixings Generic Rainhead TPO Scupper Enviroclad Waterproofing Membrane sealant and tape by builder 4mm rebate for scupper Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from EC04 Enviroclad Scupper Outlet EC04

5 Enviroclad Waterproofing Membrane Consider keeping floodheight of membrane above the parapet, eliminating the possibilty of water ingress under the metal roof 'Z' Scupper Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from 'Z' = variable according to wind zoning. please refer to table 7 E2/S1 * Gutters must be sized to E2/S1 paragraph please refer to fig 64b & 64c E2/S1 * ll external corners must be have a minimum 5mm radius. * The membrane must extend across the top of the parapet and down the outside of the parapet. * The top of the parapet substrate, must be angled to allow water to run off the top of the parapet. * ll fixings for the cap flashing, must be through the side of the flashing. * pply cut edge sealant to all cut edges of reinforced membrane. * No fillets required with Enviroclad. EC05 Enviroclad Parapet Gutter EC05

6 Enviroclad Waterproofing Membrane Clamped drain as overflow through Parapet SDM049 Clamped Drain or overflow 80mm / 100mm through base of gutter SDF110 Fixing Bar only required if not using a Parapet Cap Sealant to cladding Outlet flange 231mm 75mm Generic Rainhead Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from * pply cut edge sealant to all cut edges of reinforced membrane. * No fillets required with Enviroclad. EC06 Enviroclad Parapet Gutter / Outlet / Overflow EC06

7 SDF110 Fixing Bar only required if not using a Parapet Cap Clamped drain as overflow through Parapet Sealant to cladding by builder Enviroclad Waterproofing Membrane 75mm EC07 Enviroclad Overflow through Parapet EC07

8 Enviroclad Waterproofing Membrane Fixing Bar SDF110 Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from Enviroclad Waterproofing Membrane Fixing Bar SDF110 EC08 Enviroclad Barge Edges with Fastening Bar EC08

9 RB Flashing Tape non-bituminous Min. 150mm as per E2/S1 Enviroclad Waterproofing Membrane Min. 150mm as per E2/S1 EC09 Enviroclad Wall Upstands behind Cavity EC09

10 Note: Roofspec would only advise using a pressure bar detail where a Chase detail is not practical sealant STP860 SDF110 Fixing Bar with STP870 water cut-off mastic sealant between membrane and wall for a compression seal Chase Flashing and sealant by Main-Contractor SDF110 Fixing Bar with STP870 water cut-off mastic sealant between membrane and wall for a compression seal 'Z' Minimum upstand 150mm Minimum upstand 150mm 'Z' Enviroclad Waterproofing Membrane Enviroclad Waterproofing Membrane 5mm 5mm Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from EC10 Enviroclad Chase or Face Upstand EC10

11 Finish Membrane 100mm min. up framing at ends Finish Membrane 100mm min. up framing at ends Interior floor level lum joinery Min. 100mm as per E2/S1 Enviroclad Waterproofing Membrane 1.5mm thickness for decks Min. 100mm as per E2/S1 5mm Gap 5mm Gap Note: recommend a trafficable overlay system is installed over all membrane deck types other than Dec-K-ing EC11 Enviroclad 100mm Door Threshold to deck EC11

12 Metal Cap Flashing to allow for movement Enviroclad Waterproofing Membrane 150mm Seismic Gap determined by designer Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from EC12 Enviroclad Construction Joint EC12

13 Pitched Roofing. Longrun 150mm 150mm 2 fall Pitched Roofing Tiles Finish membrane to 150mm minimum vertical height from high point of the membrane roof. Support mermbrane under pitched roofing with flood-board 2 fall EC13 Enviroclad Membrane to Pitched roof Transition EC13

14 DryLight skylight lum frame / clear glazing Enviroclad Waterproofing Membrane Min. 150mm Upstand as per E2/S1 * pply cut edge sealant to all cut edges of reinforced membrane. * No fillets required with Enviroclad. EC14 Enviroclad Skylight upstand EC14

15 Minimum 40mm Weld 150mm Minimum Enviroclad Waterproofing Membrane Enviroclad Moulded External Corner Fully welded Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from EC15 Enviroclad External Corner * pply cut edge sealant to all cut edges of reinforced membrane. EC15

16 Min. 40mm Weld Enviroclad Waterproofing Membrane Enviroclad Moulded Internal Corner Fully welded 150mm Minimum Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from * pply cut edge sealant to all cut edges of reinforced membrane. all cut edges EC16 Enviroclad Internal Corner EC16

17 Cladding underlay 150mm TPO Corner Diverter welded to Enviroclad base and upstand Enviroclad Waterproofing Membrane continue past drip edge by 150mm under cladding and cavity Enviroclad Waterproofing Membrane 150mm EC17 Enviroclad Kick-out Diverter EC17

18 Wall Underlay and cladding cover membrane upstand min. 115mm 150mm TPO Corner Diverter welded to Enviroclad base and upstand Enviroclad Waterproofing Membrane 150mm Drip-edge termination Bar EC18 Enviroclad Kick-out Diverter EC18

19 Enviroclad Waterproofing Membrane Laptape SMT076V Metal Roofing Metal Ridge Flashing refer NZBC E2/S1 table 7 for dimensions and table 21 for materials compatibility 'Z' 'Z' = variable according to wind zoning. please refer to table 7 E2/S1 EC19 Enviroclad to Mansard Roofing Junction EC19

20 104mm TPO Cavity Vent STP607 Grey only (with Black Cap) How many vents? recommends 1 vent per 50m2 area. Ensure cross ventilation between timber supports. Note: Venting not required if specifying Warmroof or WarmSpan systems 250mm lum Cavity Vent IMV111 Grey IMV112 White 215mm 310mm TPO Pipe Seal 25mm - 225mm Enviroclad Waterproofing Membrane Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from EC20 Enviroclad Cavity or substrate Vents EC20

21 Note: Membrane is suitable to be installed to flue outer-liners reaching temperatures up to 60 C. Pipe overflashing by plumber or flue supplier Sealant STP870 Water Cut-off Mastic Stainless Steel Hose clamp Enviroclad Waterproofing Membrane Enviroclad Non-Reinforced Membrane Heat welds EC21 Enviroclad Oversized Pipe or Flue Penetration EC21

22 Goose-neck allowing wiring or conduit to be passed through Pipe over-flashing by plumber Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from Sealant STP870 TPO pipe seal 25mm - 225mm welded to Enviroclad Waterproofing Membrane EC22 Enviroclad Pipe Penetration Showing Goose-neck for ir-con Conduit EC22

23 Round Support post brackets Wall Mounted Bracket Enviroclad with welded strip to shroud bracket fixings Beam to span from post supports Enviroclad Waterproofing Membrane Min. 100mm Plant Mount support bracket Fixed to round post above waterproofing detail Beam to span from post supports Wall Mounted Steel Bracket to support beam Round support post welded to flat plate which is to be bolted to the main structure under the substrate EC23 Enviroclad Plant Mounting Posts or Wall supports NOTE: Brackets to be manufactured specific to requirements and spaced according to Plant weight and beam spanning abilities 01/12/2016 EC23

24 solution for very difficult shaped penetrations. Note that all surfaces in contact with Pourable sealant must be primed with SEC034 Lap primer. This includes all pipes, bolts, brackets and TPO sealant surround. For specific requirements contact Roofspec for advice Example Bracket STP460 Pourable sealant White only must be min. 25mm of sealant around all surfaces Enviroclad Pourable pocket surround heat welded to membrane sheet Enviroclad Waterproofing Membrane Multiple penetrations must be Min. 25mm apart Example: square post minimum 25mm minimum 25mm EC24 Enviroclad Pourable TPO Pockets EC24

25 Consider Detail EC23 as a better option for supporting Mechanical Plant on membrane roofs. lthough Roofspec do not recommend fixing posts or plant through the top of Membrane roofs or decks if this is required then use of a plinth detail provides that fixings by other trades are keep off the main deck flood area. Roofspec recommend that any fixing of plant is kept independent of the membrane roof ideally through vertical surfaces such as parapets. ll fixings must be sealed. Note: Roofspec or our pproved pplicators do not warranty fixings installed by other trades. Bracket / Bolt with compression washers both sides of bracket. By others 40mm Weld SMT076V Laptape to seal 40mm Weld Plywood to comply with current Roofspec Masterspec specification EC25 Enviroclad Plinth Details for fixing of mechanical plant by others EC25

26 Square post through deck Timber Moulding installed by builder Overflashing membrane upstand Enviroclad Waterproofing Membrane Enviroclad Moulded External Corner Min. 100mm Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet available from EC26 Enviroclad Square Post through Deck EC26

27 Enviroclad Waterproofing Membrane Enviroclad TPO Batten Welded directly to Enviroclad TPO membrane, no penetrations. Battens can be placed at any point along the roof as long as they don't inhibit watershed 25mm Heat weld 35mm EC27 Enviroclad TPO Welded Batten STP219 EC27

28 STEP 4. Cladding to seal to saddle flashing *NOTE: refer further advise from E2/S1 fig12 for saddle detail STEP 1. Enviroclad behind cavity batten fully supported by substrate Finish 150mm min. cover over & beyond the parapet junction STEP 3. *Saddle Flashing over cavity batten, directly behind cladding, refer Fig12 E2/S1 50x50mm Internal-corner Flashing by cladding supplier Behind saddle flashing extended to bottom of cladding. STEP 5. Metal Cap flashing to seal to saddle flashing Waterproofing membrane to detail over cladding 50mm 50mm 5 Sealant Bead x 2 for Parapet Cap 50mm Waterproofing membrane EC28 Enviroclad Parapet Junction Methodology EC28

29 3 SDM057 80mm PVC llthrough Deck Drain SDM mm PVC llthrough Deck Drain Balcony Drains llproof llthrough Multi-deck Drains 23/3/2016 Drainage

30 Outlet or Overflow SDM049 80mm / 100mm 121 Outlet or Overflow SDM mm mm insert Note requires approx. 300mm depth to fit a 100mm 88 bend to dropper SDM055 80mm side exit Drain or Overflow 100mm depth SDM056 80mm side exit deck drain 100mm depth Note requires approx. 240mm depth to fit an 80mm 88 bend to dropper mm Retain Collar to use as an Overflow Deck Drain SDM050 refer SDM049 for dimensions Note: Metal components are 304 Grade Stainless Steel 100mm depth 230 Flowrates in Litres / Sec SDM mm = 7.6 SDM049 80mm/100mm = 3.26/5.09 SDM050 80mm/100mm = 3.26/5.09 Clamped Drains and Overflows quaknight 23/3/2016 Drainage

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208 Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan

More information

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017 SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746

More information

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. BRANZ Appraised No. 678 Ref: P3200 Rev 1 February 2016 Page 1 of 5 1.0 PREAMBLE:

More information

Viking dec-k-ing. membrane. Product. BRANZ APPRAISAL No. 411 (2011) Scope. Appraisal No.411 [2011] BRANZ Appraisals

Viking dec-k-ing. membrane. Product. BRANZ APPRAISAL No. 411 (2011) Scope. Appraisal No.411 [2011] BRANZ Appraisals Product Appraisal No.411 [2011] 1.1 Viking Dec-K-ing PVC Waterproofing Membrane is a reinforced polyvinyl chloride (PVC), adhesive fixed sheet waterproofing membrane designed to be used on pedestrian decks

More information

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland Product Appraisal No.557 [2007] BRANZ Appraisals 1.1 The Nu-Wall Aluminium Direct Fixed Cladding System is a direct fixed, interlocking powder coated aluminium weatherboard system. It is designed to be

More information

SS806 StoStucco Roughcast System 1

SS806 StoStucco Roughcast System 1 SS806 StoStucco Roughcast System 1 Stoanz Ltd Authorized partner of Sto AG STOSTUCCO PEBBLE DASH ON STO S/S LATH SPECIFICATION STOSTUCCO ROUGHCAST ON STO STAINLESS LATH CONSTRUCTION BRANZ Appraisal No

More information

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME

More information

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only) Outline NBS Specification Protec System to PVC Single Ply (Waterproofing Only) This document is a guide to assist in the production of tender documents only and is not project specific. A site survey is

More information

ALLMET CONTINENTAL INSTALLATION GUIDE

ALLMET CONTINENTAL INSTALLATION GUIDE ALLMET CONTINENTAL INSTALLATION GUIDE www.allmet.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Allmet Continental

More information

Trims for flat roofing. GRP Trims for flat roofing

Trims for flat roofing. GRP Trims for flat roofing Trims for flat roofing GRP Trims for flat roofing SUITABLE FOR BOTH NEW BUILD AND REFURBISHMENT PROJECTS ROOFLOCK GRP Trims for flat roofing Maintenance free and easy to install Lightweight, with superior

More information

GRP Flat Roofing Edge Trims

GRP Flat Roofing Edge Trims GRP Flat Roofing Edge Trims Compatible with GRP, rigid and flexible polyester, polyurethane, acrylic and alkyd systems. Trim Brochure and Technical Specification Guide General Information The Easy To Use

More information

Plastercrete. Drained & Ventilated AAC Facade System Design and Installation Guide 100% NZ OWNED. plastercrete.co.nz.

Plastercrete. Drained & Ventilated AAC Facade System Design and Installation Guide 100% NZ OWNED. plastercrete.co.nz. Plastercrete aac facade system Drained & Ventilated AAC Facade System Design and Installation Guide 100% NZ OWNED plastercrete.co.nz Contents TABLE OF CONTENTS 1 1 GENERAL DESCRIPTION 4 2 COMLIANCE WITH

More information

SECTION TURBINE VENTILATORS

SECTION TURBINE VENTILATORS SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.

More information

Roofgard Paving Support System

Roofgard Paving Support System Roofgard Paving Support System CI/SfB (47) January 2007 Adjustable paving support system for paved and raised deck applications One of a range of Roofgard accessories specially designed to meet the exacting

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.

More information

BENCHMARK Evolution Axis

BENCHMARK Evolution Axis Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL

More information

RUBBERGARD EPDM SA APPLICATION GUIDE

RUBBERGARD EPDM SA APPLICATION GUIDE RUBBERGARD EPDM SA APPLICATION GUIDE I. MEMBRANE APPLICATION... 2 A. MEMBRANE... 2 II. MEMBRANE ATTACHMENT... 2 A. MEMBRANE PREPARATION... 2 B. MEMBRANE APPLICATION... 2 III. SEAMING... 3 VI. MEMBRANE

More information

PREFA Aluminiumprodukte GmbH Page 1 of 25

PREFA Aluminiumprodukte GmbH Page 1 of 25 Tender Specifications 120901 PREFALZ Double Standing Seam_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------

More information

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING

HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING ROCCO ROMERO, RA WISS, JANNEY, ELSTNER ASSOCIATES, INC. 960 South Harney St., Seattle, Washington 98108 Phone: 206-622-1441 Fax: 206-622-0701 E-mail: rromero@wje.com

More information

AQUABLOK INTERIOR WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 724 [2017]

AQUABLOK INTERIOR WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 724 [2017] WATERPROOFING MEMBRANES This Appraisal replaces BRANZ Appraisal No. 724 (2011) BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05

More information

PREFA Aluminiumprodukte GmbH Page 1 of 21

PREFA Aluminiumprodukte GmbH Page 1 of 21 Tender Specifications 120901 PREFA Shingles_2012 ---------------------------------------------------------------------------------- 01. Text GENERAL PRELIMINARY REMARKS Roof ----------------------------------------------------------------------------------

More information

NOVAFLEX AND POLIBIT ROOF AND DECK WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 520 [2013] Appraisal No. 520 (2013) Amended 02 March 2016

NOVAFLEX AND POLIBIT ROOF AND DECK WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 520 [2013] Appraisal No. 520 (2013) Amended 02 March 2016 NOVAFLEX AND POLIBIT ROOF AND DECK WATERPROOFING Amended 02 March 2016 BRANZ Appraisals Technical Assessments of products for building and construction. Jaydex International Ltd PO Box 100 000 North Shore

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 07 40 00 Roofing 1. General Several factors repeatedly show up during the inspection of roofs that have failed prematurely. They include inappropriate use of materials, poor drainage systems, poor details

More information

Insulating systems used in agricultural and industrial buildings

Insulating systems used in agricultural and industrial buildings Insulating systems used in agricultural and industrial buildings INTRODUCTION Since years, RECTICEL is a leading manufacturer of systems for internal insulation. The EUROTHANE product range has been especially

More information

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00 Description Page No Summary Amount Summary 1/7 230,694.60 22,019.25 22,642.65 2/6 96,801.30 80,150.60 114,056.00 Total Per Unit (MYR) 327,495.90 102,169.85 136,698.65 Total Unit(s) X 1 2 2 Total Per Type

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

SITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT

SITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT SETTING OUT Correct to boundaries Correct to building lines? Diagonals accurate? Levels correct? EXCAVATIONS Adjoining structures OK? Centres of foundations line with walls? Bottoms of trenches uniform,

More information

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Waterproofing Handbook

Waterproofing Handbook Waterproofing Handbook Wet-seal R Your Waterproofing Specialists Your Waterproofing Specialists Basic Hand Book for Waterproofing Builder s/client Responsibilities Safe Working Site Duty Of Care The Builder/Client

More information

How do you install yours?

How do you install yours? How do you install yours? Darrell Paul Qualistat Building Performance Consultants CSA 440 Just about adding Peel & Stick? 1 Window and door problems Photos / videos Video available for viewing at INSTAGRAM

More information

Construction details:

Construction details: Extension Specifications, 23 Nightingale Avenue Floor area (internal): 27.6m 2 Gross floor area: 31.9m 2 Construction details: Walls Construction from inside: (Option A) wet plaster (airtightness layer

More information

BUILD A SHOWER CUBICLE

BUILD A SHOWER CUBICLE BUILD A SHOWER CUBICLE Building a shower cubicle requires some experience in carpentry and tiling. You also need a degree of expertise in wiring and plumbing in order to install a shower unit. By all means

More information

RS32 Multi-Section Skylight System under/over seam clip double diverter

RS32 Multi-Section Skylight System under/over seam clip double diverter INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series

More information

Balconies Information. How to waterproof and reduce efflorescence

Balconies Information. How to waterproof and reduce efflorescence Balconies Information How to waterproof and reduce efflorescence With existing structures, the balcony may be showing efflorescence as a bi-product of poor waterproofing design. Efflorescence in the construction

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08

More information

Finestone Stucco Ultra Wall System

Finestone Stucco Ultra Wall System Finestone Stucco Ultra Wall System Premium impact and puncture resistant, rain screen design cement plaster stucco system with enhanced water management Typical Details BLANK PAGE Finestone Stucco Ultra

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO SECTION 01010 - SCOPE OF WORK PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General provisions of Contract, General Conditions and Technical Specification Sections, apply to this Section. 1.02 PROJECT DESCRIPTION

More information

Chapter 2 Understanding The Problem

Chapter 2 Understanding The Problem Chapter 2 Understanding The Problem What Causes Most Of The Problems With Stucco? EIFS was originally intended to seal and insulate the exterior of the home from the elements. Problems occur when poorly

More information

SI T T FST

SI T T FST SI 440-600-700-700T-780-780T-900-1100 Freestanding TAPER TOP Open Fire - Wood Burner Installation Instructions Note: FLUE SYSTEMS Casing. Flue System may require to be Doubled Lined to Comply. Ref ASNZS:2918:2001

More information

Sub-construction for Wall-mounted Longlight

Sub-construction for Wall-mounted Longlight modular skylights Sub-construction for Wall-mounted Longlight Subconstruction for Wall-mounted Longlight at 5-40 pitch modular skylights in a wall-mounted longlight solution, can be installed on a sub-construction

More information

Finestone Stucco System

Finestone Stucco System Typical Details Finestone Stucco System Cement Plaster Stucco 1. Typical Finestone Stucco System with Steel Framing 2. Typical Finestone Stucco System with Wood Framing 3. Typical Finestone Stucco System

More information

EXT.CORNER - MANUF.STONE/FC SHEET

EXT.CORNER - MANUF.STONE/FC SHEET STOARMAT RENDER SYSTEM 7.5/9.0mm REBATED FC SHEET TIMBER FRAMING WALL UNDERLAY CONTINUOUS AROUND CORNERS, POLYPROPYLENE FLASHING TAPE APPLIED TO PROTECT WALL UNDERLAY 75mm MIN.WIDE STO upvc CLIP ON FLASHING

More information

Built to Last a Lifetime

Built to Last a Lifetime Built to Last a Lifetime Welcome to Lincoln 2 This brochure will introduce you to Lincoln Steel Buildings from the ground up starting with the framing of the building all the way to the roof and finally

More information

Senturion TM III Wall System

Senturion TM III Wall System Senturion TM III Wall System TYPICAL DETAILS 1017666 1. Senturion III Wall System Application (Plan VIew) 2. Senturion III Wall System Application (Isometric View) 3. Aesthetic Groove (Plan VIew) 4. Insulation

More information

Rediflow Concrete Gas Flue System

Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN

More information

Lithia Dodge East 5500 L St. Omaha, NE

Lithia Dodge East 5500 L St. Omaha, NE Lithia Dodge East 5500 L St. Omaha, NE Perimeter Photos Failed Joints at North Rear Wall Control Joints Look Good Inadequate Downspout Elbows Erosion Along Wall Minor Efflorescence Roof Section Photos

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

External Thermal Insulation Composite System Insulation below ground level

External Thermal Insulation Composite System Insulation below ground level Insulation below ground level 1. Concrete wall substrate 2. Aluminium starter base profile 3. Terraco Styrofix (adhesive) 4. Mechanical fastener 5. a. Graphite enhanced polystyrene board b. HD polystyrene

More information

RS24-10 Single-Section Skylight System

RS24-10 Single-Section Skylight System INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15420 DRAINAGE AND VENT SYSTEMS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All cleanouts above finished (accessible and non-accessible) ceilings shall be extended to the floor above. B. Do

More information

DuPont RainVent Batten Installation Guidelines

DuPont RainVent Batten Installation Guidelines DuPont RainVent Batten Installation Guidelines Purpose: To improve the ventilation and draining space behind a cladding system or 3-coat stucco system in residential construction. The DuPont RainVent Batten

More information

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague, Part E Pack Dear Colleague, This is the first 2017 update to the Part E Robust Details Handbook. In this update pack, we have focussed on clarifying the situation on incorporating underfloor heating (UFH)

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

The HardieZone System: HZ5 Care and Maintenance Guide

The HardieZone System: HZ5 Care and Maintenance Guide The HardieZone System: HZ5 Care and Maintenance Guide Congratulations on having James Hardie products on your home! We would like to share with you some basic information about the products and how to

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

RUUKKI FORMA DESIGN INSTRUCTION

RUUKKI FORMA DESIGN INSTRUCTION www.ruukki.com RUUKKI FORMA DESIGN INSTRUCTION 1. General Ruukki Forma is a complete façade system in which Ruukki energy panels form an energy efficient base structure and Ruukki cladding products finalize

More information

Examples of Installation Method

Examples of Installation Method Examples of Installation Method ALPOLIC/fr is widely used for external claddings and some interior surfaces, while ALPOLIC is used mainly for signage. Both materials are also used for civil works and other

More information

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209) City of Hughson Building Safety Division 7018 Pine Street Hughson, CA 95326 (209) 883-4054 RESIDENTIAL ATTACHED PATIO COVERS Patio covers are one story roofed structures not more than 12 feet above grade,

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System

BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System EXPIRES MAR 2018 BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System Product 1.1 The PLASTERCRETE NZ AAC Wall Panel System (PAWPS) is a drained and ventilated masonry veneer wall cladding

More information

Nouveau BBQ Single Flue

Nouveau BBQ Single Flue Nouveau BBQ 900-1100-1250-1500 Single Flue Outdoor BBQ Cooking Fire Wood Burner Installation Instructions FLUE SYSTEMS Casing. Flue system may require to be doubled lined to comply. Ref ASNZS:2918:2001

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards SECTION 07185 TRAFFIC MEMBRANE PART 1 GENERAL 1.1 SECTION INCLUDES A. Traffic membrane, consisting of welded seam PVC waterproofing, over f following surfaces: 1. Decks, balconies, and sun porches 2. Walkways,

More information

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16 long / 1/2 thick or 16 oz. copper Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)

More information

e x a n g l e installation guide exangle Finishing Sections

e x a n g l e installation guide exangle Finishing Sections e x a n g l e installation guide exangle Finishing Sections rondo exangle Finishing Sections CORNER BEADS 90º external corner beads are available in two profiles. Use P01 for a sharper finish or P32 for

More information

Compliance Document for New Zealand Building Code Clause E2 External Moisture

Compliance Document for New Zealand Building Code Clause E2 External Moisture Compliance Document for New Zealand Building Code Clause E2 External Moisture Prepared by the Department of Building and Housing This Compliance Document is prepared by the Department of Building and Housing.

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations. SECTION 071700 - BENTONITE WATERPROOFING PART 1 - GENERAL 1.1 WORK SUMMARY A. The work of this section includes, but is not limited to the furnishing and installing the following materials, per project

More information

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer) NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3340 Reissued 05/2017 This report is subject to renewal 05/2018. DIVISION: 07 00 00 THERMAL

More information

Kingspan Day-Lite Klick

Kingspan Day-Lite Klick Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation

More information

11 FLAT ROOF CONSTRUCTION

11 FLAT ROOF CONSTRUCTION CARPENTRY & JOINERY FCA CARPENTRY & JOINERY THEORY 11 FLAT ROOF Flat Roofs The definition of a flat roof is any roof which has a slope of less than 10 degrees or a fall ratio of 1:6. This type of roof

More information

MIGUTAN FP110 (Previously FP 90, name changed as part of metric standardization program)

MIGUTAN FP110 (Previously FP 90, name changed as part of metric standardization program) Manufacturer: MIGUTAN FP110 (Previously FP 90, name changed as part of metric standardization program) Watertight, Plaza Deck, & Split Slab Expansion Joint EMSEAL JOINT SYSTEMS, LTD 25 Bridle Lane Westborough,

More information

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO Maxwell C. Baker: Roofs : Design Application and Maintenance IT S ALL IN THE DETAILS and everything is connected COMPONENTS AND THEIR

More information

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW. AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW www.stromatech.com AIR BARRIER DESIGN PRINCIPLES Building Regulations Approved Document Parts L1A & L2A currently requires that new buildings have to achieve a

More information

FLUID APPLIED WATERPROOFING

FLUID APPLIED WATERPROOFING SECTION 07120 FLUID APPLIED WATERPROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 09200 - Metal Studs, Metal Lath, Suspension Ceilings, Plaster, and Stucco.

More information

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM 07500/MUL PART 1 - GENERAL 1.01 Description A. Scope: 1. Thermoplastic Self Adhering Single Ply Roofing 2. Insulation B. Related

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08

More information

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork Insulation CI/SfB (21.9) Rn7 M2 First Issue May 2017 e with retaining clip TW50 STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY 25 mm / 50 mm residual cavity Kingspan Thermawall TW50 Outer

More information

SECTION METAL BUILDING SYSTEMS

SECTION METAL BUILDING SYSTEMS SECTION 13 3419 PART 1 GENERAL 1.01 SECTION INCLUDES A. Manufacturer-engineered, shop-fabricated structural steel building frame. B. Insulated Metal wall and roof panels including gutters and downspouts.

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components. 84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes 90 System Components installation/ SYSTEM COMPONENTS INSTALLATION ADVICE LAPPING and JOINTING

More information

Modular Buildings. Installation Manual

Modular Buildings. Installation Manual Modular Buildings Installation Manual 1. Introduction 2 2. Marking Installation Area 2 3. Speed-Lok Operation 2 4. 'Z' Base Trim 3 5. Less Floor Walk-Ins 3 6. Floor Panel Installation 4 7. With-Floor Installation

More information

SWING DOOR SPECIFICATION

SWING DOOR SPECIFICATION SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified

More information

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms. PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels. 1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation

More information

TC54. for architects & designers. Dimensions Clearances Venting

TC54. for architects & designers. Dimensions Clearances Venting for architects & designers TC54 Series D Dimensions Clearances enting IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction

More information

REV:6-30/09/30. Liquid Rubber Timber Specification

REV:6-30/09/30. Liquid Rubber Timber Specification REV:6-30/09/30 Liquid Rubber Contents: 1. Preparation 2. Application 3. Additional Information 4. Things To Be Aware Of When Applying To Timber 1. Preparation: Prior to commencing ensure the decking is

More information

When I started tiling, we didn t do our own shower pans that BATHS

When I started tiling, we didn t do our own shower pans that BATHS BATHS Preventing Leaks in Tiled Showers Detail the pan properly before any tile is installed BY TOM MEEHAN Photos by Roe Osborn When I started tiling, we didn t do our own shower pans that job fell to

More information

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals Appraisal No. 959 [2017] HYDRATHANE INTERIOR WATERPROOFING MEMBRANE BRANZ Appraisals Technical Assessments of products for building and construction. Construction Chemicals Pty Ltd 49-57 Davis Street Wingfield

More information

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. SECTION D Wall Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE D2 D2 D4 D5 System Specifications Stud One Side Stud Both Sides Stud and Furring Channel Resilient

More information

Radon Vent Pipe System. Labeling Performance Indicators

Radon Vent Pipe System. Labeling Performance Indicators Section 6 Radon Vent Pipe Labeling Performance Indicators Radon Vent Pipe System Connected after sub-grade system installed Pipe cannot be trapped Provide space in chases Support at each floor level Discharge

More information

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description Roofing Product Data Sheet Edition 11.2014 / xtra UK Identification no. 02 09 45 05 100 0 000019 Version no. 03 S-Vap 5000E SA Self-adhesive Vapour Barrier Product Description S-Vap 5000E SA is a multi-layer

More information

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to

More information