Durisol: Insulated Concrete Form (ICF) Wall Forming System

Size: px
Start display at page:

Download "Durisol: Insulated Concrete Form (ICF) Wall Forming System"

Transcription

1 Durisol: Insulated Concrete Form (ICF) Wall Forming System Bruce Coldham, Coldham Architects, LLC Affordable Comfort. - Westford, MA October, 2003

2 An explanation of the material and assemble of the wall system A discussion of the properties of the wall system Four project case examples 2

3 Insulated Concrete Form (ICF) Material Shredded (recycled) mineralized wood material Combined in a cementitious slurry and pressed into a wallform block Mineral wool insulation plugs inserted into the core 3

4 Below grade foundation walls Above grade walls 4

5 First Course is set out precisely on footing...by masons or carpenters? It is formwork, not a bearing CMU wall. Use string line 5

6 Wood biscuits to align the interior face. Wallform blocks are dry-stacked 6

7 Door and window openings 7

8 Cutting wallforms 8

9 Steel reinforcing Steel reinforcing bars horizontally and vertically 9

10 Wall Form Shoring Prevent corner blowouts Prevent uplift and leaking of horizontal joints but this material is much heavier than EPS blocks Align and stabilize the top course 10

11 Fill core with concrete Pump placement 3,000 psi and pea stone. We laid the wall forms to their full height and poured the core in three lifts (circuits) in a single pumping operation. 11

12 Wall finishes. and air barrier 12

13 Exterior wall finishes The wall form material accepts mechanical fastening of wood and other furring materials using screw fasteners. 13

14 Waterproofing.. 14

15 Supporting intermediate floors 15

16 Supporting intermediate floors Ledgers bolted to the concrete core through 5 diameter shear connectors 16

17 Lintels.. Header beams over rough openings Wallform create reinforced concrete lintels. Wrapped engineered lumber beam ends in wallformed beam pockets. 17

18 Accommodating electrical circuitry 18

19 Material properties: 19

20 Material properties: A reliably well insulated masonry wall Insulation value R 8 to 20 Theoretical insulation value is achievable without requiring heroic oversight 20

21 Material properties: A non-combustible wall assembly Surface Burning (ASTM-E84) Smoke Developed: 11 Flame Spread Index: 0 UL/ULC (S101) 44 hour rating 21

22 Material properties: Air and vapor permeable affording a vapor storage potential Vapor Permeability 20.5 (dry) (100%RH) ng / (Pa s m) 14 (dry) - 18 (100%RH) perm - inch Vapor Permeance 1.75 imperial perm for 8 8 block ng/(pa s m 2 ) per 50 mm The breathability of the wall system, particularly with a lime-based plaster applied to the interior walls, which maintains the wall s moisture permeability. The exterior wall acts as something of a humidity reservoir with excess humidity taken up by the exterior walls and released back to the interior as interior RH levels diminish. 22

23 Material properties: No capacity to "lift" moisture through capillary action in the wallform material meaning that the wallform material is a free draining medium No propensity to freeze-thaw damage 23

24 Material properties: Completely non-biodegradable wall system 24

25 Material properties: Unable to support the growth of molds and mildew The cementitious matrix is too alkaline Not attractive to termites, but wallform interstices appear to allow passage for termites. 25

26 Material properties: Sound absorbent Noise reduction coefficient 0.70 to 0.95 sound attenuation properties especially useful in large interior multi-use space. (Leave Durisol material unfinished above 7 ) 26

27 Material properties: Regionally appropriate material? The wall form seems appropriate use of the mixed hardwood forest produce of the US northeast, which otherwise has limited use in building. 27

28 Small, Timber Framed House Francestown, NH Completed: 2002 Building Area: 1,500 s.f. Wall system cost: $11/ s.f. Design requirements: Robust, durable support complement for a timber frame 28

29 Concentrate the frame investment overhead let a less expensive (and more suitable) material be the wall 29

30 30

31 In this instance, the wallforms were laid up on a conventional concrete foundation wall 31

32 Great Barrington House Gt. Barrington, MA Completed: 2001 Building Area: 3,500 s.f. Wall system cost: $12/ s.f. Design requirements: Interior floor flows continuous to the exterior. Durable substrate for vegetated walls 32

33 Great Barrington House Gt. Barrington, MA METAL ROOF VENT SELECT PINE TRUSS RAFTER 1 X 6 WHITE CEDAR T&G BOARDS 5/4" X 2" WHITE CEDAR 2'-0" OVERHANG 5/4" X 14" WOOD FRIEZE BOARD 3/4" PLYWOOD Durisol I.C.F. ROOFING FELT 3/4" C.D.X OR OSB ROOF SHEATHING WOOD ROOF 24" o.c. R-40 (12") BLOWN-IN CELLULOSE INSULATION 1 X 3 16" o.c. 5/8" GYPSUM BOARD OVER POLY. AIR / VAPOR MEMBRANE SEAL AIR / VAPOR MEMBRANE TO WALL PLATE 2 X 10 WALL PLATES 1/2" DIA. ANCHOR 48" o.c. WINDOW BLOCK HARDWOOD WINDOW SILL 1 X 3 WOOD SILL APRON Wall system design options: Conventional stud frame on conc. foundation wall S.I. P. on conc. foundation wall ELEV. MALE - 105'-3" FEMALE - 107'-8" T.R '-11" EXTERIOR STUCCO DURISOL BLOCK mm THICK MINERAL WOOL INSULATION INSERT - 80mm CONCRETE INFILL 5/8" GYPSUM WALLBOARD 1 X 4 WOOD BASEBOARD 2" CONCRETE TOPPING SLAB (FINISH FLOOR) 3/4" SUB-FLOOR 9 1/2" TJI JOISTS 1/2" DIA. ANCHOR 16" o.c. 2X6 WALL PLATES WOOD SHINGLES OVER BUILDING WRAP MEMBRANE WOOD FRAMEWALL - 24" O.C. W/ 1/2" OSB SHEATHING 7" CELLULOSE INSULATION 5/8" GYPSUM WALLBOARD 2 X 3 STRAPPING 1 X 4 WOOD BASEBOARD 1 1/2" RIGID INSULATION THERMAL BREAK 2X6 WALL PLATES WOOD SHINGLES OVER BUILDING WRAP MEMBRANE S.I.P /2" RIGID INSULATION (EPS) W/ 1/2" STRESSED SKIN OSB, BOTH SIDES 5/8" GYPSUM WALLBOARD 1 X 4 WOOD BASEBOARD 1 1/2" RIGID INSULATION THERMAL BREAK 2" CONCRETE TOPPING SLAB (FINISH FLOOR) 3/4" SUB-FLOOR 9 1/2" TJI JOISTS 2" CONCRETE TOPPING SLAB (FINISH FLOOR) 3/4" SUB-FLOOR 9 1/2" TJI JOISTS ELEV. MALE - 96'-8" FEMALE - 99'-1" T.R. - 99'-4" #4 BAR HORIZONTAL REINFORCING #4 BAR VERTICAL REINFORCING WATERPROOFING (BELOW GRADE) 6" FOOTING DRAIN 4" CONCRETE SLAB 1" RIGID INSULATION DAMP-PROOF MEMBRANE 1/2" DIA. ANCHOR 16" O.C. WATERPROOFING (BELOW GRADE) 6" FOOTING DRAIN VERTICAL REINFORCING HORIZONTAL REINFORCING 4" CONCRETE SLAB 1" RIGID INSULATION DAMP-PROOF MEMBRANE 1/2" DIA. ANCHOR 16" O.C. WATERPROOFING (BELOW GRADE) 6" FOOTING DRAIN VERTICAL REINFORCING HORIZONTAL REINFORCING 4" CONCRETE SLAB 1" RIGID INSULATION DAMP-PROOF MEMBRANE 9" X 20" CONCRETE STRIP FOOTING #4 DOWEL BAR #4 HORIZONTAL FOOTING REINFORCEMENT CONCRETE STRIP FOOTING DOWEL BAR HORIZONTAL FOOTING REINFORCEMENT CONCRETE STRIP FOOTING DOWEL BAR HORIZONTAL FOOTING REINFORCEMENT 33

34 Wholefood farm store Ghent, NY Completed: 2003 Building Area: 9,000 s.f. Wall system cost: $16/ s.f. Design requirements: Rodent exclusion Sound absorption 34

35 Wholefood farm store Ghent, NY 35

36 Wholefood farm store Ghent, NY 36

37 Wholefood farm store Ghent, NY 37

38 Wholefood farm store Ghent, NY Cement substitution Gran Cement 38

39 Vipassana Meditation Center Shelburne, MA Completed: Project abandoned Building Area: 30,000 s.f. Design requirements: Durability a building that would last 100 s of years Non-combustibility a large building in an isolated setting Multiple accessibility many on-grade exits and entries Conform to a sloping site 39

40 Vipassana Meditation Center Shelburne, MA Design opportunity: Use the insulated mass of the structural enclosure to carry the building whilst the heating system is entirely serving the DHW need. The space heating and the DHW loads were similar in magnitude. Therefore a 50% reduction in heating system capacity was possible. 40

41 The Durisol Corporation

42 Material Properties Modulus of Elasticity (ASTM C513) E=1500 MPa compression Modulus of Rupture (ASTM C293) 1.0 to 3.0 MPa Ultimate Compression Strength (ASTM C513) 1.5 to 3.0 MPa Shear Strength: > 0.2 MPa Durisol to Concrete Bond: > 0.6 MPa 42

43 Great Barrington House Gt. Barrington, MA 43

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM ARCHITECTURAL SPECIFICATIONS MANUFACTURER: InterBlock LLC PO Box 1123, Sheboygan, WI 53082 Phone Number 920-207-7234 SECTION 03100 STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM PART 1 GENERAL 1.01 Summary

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

2003 International Residential Building Code

2003 International Residential Building Code 2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less

More information

Table of Contents. Page Title

Table of Contents. Page Title Page Title Table of Contents 1 Floor plan/ Room utilization 2 Elevation (EAST) 3 Elevation (SOUTH) 4 Elevation (WEST) 5 Elevation (NORTH) 6 Foundation plan details 7 Foundation cross sections A Main grade

More information

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT MAY 2009 prepared by N. A. JACOBSEN, P.Eng. CIVIL ENGINEERING CONSULTANT Whitehorse, Yukon ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT MAY

More information

Gold Bond BRAND Gypsum Sheathing

Gold Bond BRAND Gypsum Sheathing BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant

More information

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer) NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS

More information

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY Insulation for the Building Envelope ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax Thermasheath-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam

More information

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control It s not magic, it s engineering. Impact Sound Control GenieMat FF Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation Patents: US 8240430, US8556029, CA 2500956, CA 2503420 GenieMat

More information

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209) City of Hughson Building Safety Division 7018 Pine Street Hughson, CA 95326 (209) 883-4054 RESIDENTIAL ATTACHED PATIO COVERS Patio covers are one story roofed structures not more than 12 feet above grade,

More information

4 EXTREME FOUNDATION PANELS

4 EXTREME FOUNDATION PANELS 4 EXTREME FOUNDATION PANELS For House Crawl Space On Concrete Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions.

More information

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST This list is provided as a guide to help you understand the information that must be contained on the construction drawings. This list is not all-inclusive of all building codes but is used as a general

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division GARAGES/ONE-STORY City of Grand Rapids Building Safety Division 218-326-7601 www.cityofgrandrapidsmn.com This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building

More information

Detached Garages and Building Permits. 1 and 2 Family Dwellings

Detached Garages and Building Permits. 1 and 2 Family Dwellings Detached Garages and Building Permits 1 and 2 Family Dwellings Why do I need a permit? The City of Minneapolis adopts the State of Minnesota Building Code (MNSBC) and its associated state statutes and

More information

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

WOOD USE IN NONCOMBUSTIBLE BUILDINGS INTRODUCTION The National Building Code of Canada (NBCC) 1 requires that some buildings be of noncombustible construction under its prescriptive requirements. Its use in certain types of buildings such

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1780 Reissued 11/2017 This report is subject to renewal 11/2019. DIVISION: 06 00

More information

R Code and Commentary for 2012 NC Residential Code final 03/06/13

R Code and Commentary for 2012 NC Residential Code final 03/06/13 R602.10 Code and Commentary for 2012 NC Residential Code final 03/06/13 Commentary italicized and printed in red 1. Section R602.10 -- provides charging language for two simplified bracing approaches (isolated

More information

MID-RISE DESIGN & CONSTRUCTION

MID-RISE DESIGN & CONSTRUCTION TECHNICAL BULLETIN No.38-021616 Rev072116 MID-RISE DESIGN & CONSTRUCTION Logix effective R-values range from R-24 to R-28+ Insulated concrete forms (ICF) are becoming a main stream choice for the construction

More information

The Inspection Process. Waxhaw N.C.

The Inspection Process. Waxhaw N.C. The Inspection Process In Waxhaw N.C. This information is provided by the Waxhaw Enforcement Division to assist you in the progression of your project. Nothing in this document should be considered "Code"

More information

14' x 24' Garage Plan

14' x 24' Garage Plan 14' x 24' Garage Plan SDS-CAD Specialized Design Systems www.sdscad.com email sdscad@pcu.net Copyright 2002 14'-0" (vert)-g 24'-0" 12 in 12 GARAGE 13'-4" x 23'-4" 12 in 12 3068 19'-0" 3'-0" 2'-0" 24'-0"

More information

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire Additional Instructions and Clarifications 1. Please review ARC 4496 before beginning the project identification

More information

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: AMVIC INCORPORATED

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: AMVIC INCORPORATED 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1269 Reissued 05/2017 This report is subject to renewal 05/2018. DIVISION: 03 00 00 CONCRETE

More information

Applying for Permits to build a new house in Linn County

Applying for Permits to build a new house in Linn County Planning & Development Linn County, Iowa Building Division Linn County Building Code Residential Guidelines Single Family Dwellings Page 1 of 4 Applying for Permits to build a new house in Linn County

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE SPECIFICATION GUIDELINE Environmental Stoneworks Corporate Office 6300 East Stapleton Drive South Denver, CO 80216 Phone (303) 309-3040 Fax (303) 309-3059 www.estoneworks.com Environmental Stoneworks specification

More information

BEARING METAL STUD FRAMING

BEARING METAL STUD FRAMING L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or

More information

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

RESIDENTIAL CONSTRUCTION New Dwellings and Additions How to Obtain a Building Permit For RESIDENTIAL CONSTRUCTION New Dwellings and Additions MIAMI COUNTY, KANSAS CODE SERVICES DEPARTMENT 201 South Pearl Street, Suite 201 Paola, Kansas 66071-1777 Phone:

More information

Building Design Data

Building Design Data Building Design Data.. 1. Building Design The KORE ICF System is designed to meet the requirements of the Building Regulations 1997-2006, in the case of two storeys, single occupancy dwellings. If the

More information

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT SAMPLE GUIDE FOR RESIDENTIAL DECKS revised 7 16 Call before you dig! 1 800 272 1000 New Jersey One Call. Utility Mark Out. THIS GENERIC GUIDE IS NOT ALL INCLUSIVE

More information

SECTION PERMANENT FORMS - INSULATING CONCRETE FORMS Page 1 of 7

SECTION PERMANENT FORMS - INSULATING CONCRETE FORMS Page 1 of 7 SECTION 03 11 19 (03130). PART 1 GENERAL 1.01 SUMMARY A. Comply with the requirements for Division 1. B. Supply and installation of insulating concrete form system, installation of reinforcing steel and

More information

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE - 268-5161 Residential Accessory Structures This information has been compiled for the benefit of any person

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

The Role of Control Layers in Building Enclosure Design

The Role of Control Layers in Building Enclosure Design The Role of Control Layers in Building Enclosure Design COLIN SHANE M.ENG., P.ENG. ASSOCIATE, SENIOR PROJECT MANAGER OCTOBER 13, 2016 Disclaimer: This presentation was developed by a third party and is

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2375 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00

More information

Magnum Board Section Digicon Information Inc. Page 1

Magnum Board Section Digicon Information Inc. Page 1 Digicon Information Inc. Page 1 This section includes sheathing for exterior walls for use in a potentially damp or wet exterior cladding environment. This sheathing section forms an exterior flat plane

More information

ABOVEGROUND HOME FALLOUT SHELTER H-12-2 / November 1983 (Supercedes H-12-2 dated June 1980)

ABOVEGROUND HOME FALLOUT SHELTER H-12-2 / November 1983 (Supercedes H-12-2 dated June 1980) ABOVEGROUND HOME FALLOUT SHELTER H-12-2 / November 1983 (Supercedes H-12-2 dated June 1980) Page 1 General Information This family shelter is intended for persons who prefer an aboveground shelter or,

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1993 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00

More information

Typical Finished Basement Details

Typical Finished Basement Details Albemarle County, Virginia Typical Finished Basement Details Based on the 2012 Virginia Residential Code Finished basements must be constructed in conformance with these details. For requirements, details

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 25 GYPSUM BOARD AND PLASTER (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority

More information

Introducing TJ Insulated Structural Framing Components

Introducing TJ Insulated Structural Framing Components #TJ-9009 SPECIFIER S GUIDE TJ INSULATED HEADERS, RIM BoaRD, AND CORNERS Introducing TJ Insulated Structural Framing Components Helps meet the 2011 Federal Energy Star Homes and 2009 International Energy

More information

The better way to build TM

The better way to build TM The better way to build TM Product Catalog Exterior Wall SIP The Exterior Wall SIP is the most common panel manufactured by Thermapan with numerous applications in residential and commercial construction

More information

The Role of Control Layers in Building Enclosure Design

The Role of Control Layers in Building Enclosure Design The Role of Control Layers in Building Enclosure Design COLIN SHANE M.ENG., P.ENG., P.E. ASSOCIATE, SENIOR PROJECT MANAGER RDH BUILDING SCIENCE INC. SEPTEMBER 14, 2016 Disclaimer: This presentation was

More information

A. Source Limitations: Obtain each type of building insulation through one source.

A. Source Limitations: Obtain each type of building insulation through one source. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

INSPECTION GUIDELINES: JOIST AND UNDERFLOOR COMBO

INSPECTION GUIDELINES: JOIST AND UNDERFLOOR COMBO Joist and Underfloor Combo Page 1 of 7 Revision Date: 10/02/2017 DEVELOPMENT SERVICES BUILDING INSPECTION INSPECTION GUIDELINES: JOIST AND UNDERFLOOR COMBO INSPECTION CODE: 212, 213 SCOPE: RESIDENTIAL

More information

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016. ICC-ES Evaluation Report ESR-894 Reissued April 04 This report is subject to renewal April, 0. www.icc-es.org (800) 4-87 () 99-04 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL

More information

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee The Structural Redesign of Boyds Bear Country and its Related Systems Included in this Presentation: Background and Existing System Proposal Problem / Solution Structural System Redesigns Pre-cast Concrete

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction. Plan Examination 1 Plan ExaminationPurpose 2 Catch problems in advance of construction. 3 1 Discovery of problems in the field results in higher cost. 4 Can a good plan review eliminate all problems in

More information

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings application instructions STRAND SUBSTRATE 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH General At the time of manufacture, siding meets or exceeds the performance standards

More information

APPENDIX R STRAWBALE CONSTRUCTION

APPENDIX R STRAWBALE CONSTRUCTION APPENDIX R STRAWBALE CONSTRUCTION (Note: As submitted to the International Code Council (ICC) on 1.3.13, for proposed inclusion in the 2015 International Residential Code (IRC). Use of this document without

More information

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION DRAINAGE SOLUTIONS SINCE 1908 PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION PROVEN PERFORMANCE ARMTEC.COM

More information

STRATEGIES FOR TERMITE RESISTANCE TEK 3-9A

STRATEGIES FOR TERMITE RESISTANCE TEK 3-9A NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology STRATEGIES FOR TERMITE RESISTANCE TEK 3-9A Construction (2000) Keywords:

More information

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. A Subsidiary of the International Code Council

More information

Carpenter Level 2 Rev. September 2017

Carpenter Level 2 Rev. September 2017 Level 2 A5 Site Layout II Duration: 14 hours 7 hours 7 hours Upon completion of this unit the apprentice will demonstrate knowledge of site layout tools and equipment and their applications and procedures

More information

2013 COMMERCIAL PRODUCTS

2013 COMMERCIAL PRODUCTS 2013 COMMERCIAL PRODUCTS EXPLORE GEOMETRY AND SPACE WITHOUT COMPROMISING BUILDING ENVELOPE PERFORMANCE Commercial design considerations come with very specific challenges that can t be addressed with just

More information

Structural Insulated Panels (SIPs) Commercial, Industrial and Residential Applications

Structural Insulated Panels (SIPs) Commercial, Industrial and Residential Applications Structural Insulated Panels (SIPs) Commercial, Industrial and Residential Applications This program is registered with the AIA/CES for continuing professional education. As such, it does not include content

More information

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board + Euroclass A1 Non-combustible FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD Magply Fire PASSIVE FIRE

More information

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home Designed and built by New Mexico landscape architect John Mosely for his own Santa Fe home. The solar greenhouse shown

More information

Fairfax County, Virginia

Fairfax County, Virginia Fairfax County, Virginia Typical Finished Basement Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Wall Construction... 3 Floor/ceiling

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3758 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3089 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

DuPont RainVent Batten Installation Guidelines

DuPont RainVent Batten Installation Guidelines DuPont RainVent Batten Installation Guidelines Purpose: To improve the ventilation and draining space behind a cladding system or 3-coat stucco system in residential construction. The DuPont RainVent Batten

More information

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Wall Framing Released September 20, 2010 Updated December 4, 2012 Note: Tables for cladding attachments to wood framing have

More information

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008 SECTION 092900 - GYPSUM BOARD 1.1 SUMMARY A. This Section includes the following: 1. Interior gypsum board. 2. Tile backing panels. B. Related Sections include the following: 1. Division 06 Section "Rough

More information

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee October 12, 2010 TO: SUBJECT: PARTIES INTERESTED IN EVALUATION REPORTS ON STAY-IN-PLACE, FOAM PLASTIC INSULATING CONCRETE FORM (ICF) SYSTEMS FOR SOLID CONCRETE WALLS Revisions to the Acceptance Criteria

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION CHAPTER 26 PLASTIC SECTION BC 2601 GENERAL 2601.1 Scope. These provisions shall govern the materials, design, application, construction and installation of foam plastic, foam plastic insulation, plastic

More information

Concrete weighs about 150 pounds per cubic foot

Concrete weighs about 150 pounds per cubic foot At Bassora, where they have no timber, they make arches without any frame. The mason, with a nail and a bit of string, marks a semicircle on the ground, lays his bricks, fastened together with a gypsum

More information

Technical Bulletin. No. 21 : Insulating Basements and Crawl Spaces (Revised 7/04) hwinsulation CONTRACTORS ASSOCIATION OF AMERICA

Technical Bulletin. No. 21 : Insulating Basements and Crawl Spaces (Revised 7/04) hwinsulation CONTRACTORS ASSOCIATION OF AMERICA hwinsulation CONTRACTORS ASSOCIATION OF AMERICA Technical Bulletin 1321 Duke Street, Suite 303 Alexandria, VA 22314 (703) 739-0356 FAX (703) 739-0412 No. 21 : Insulating Basements and Crawl Spaces (Revised

More information

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION Permit No. 175 Beaver Drive, P.O. Box 486 DuBois, PA 15801 Phone: 814-375-1111 Fax: 814-375-1117 Toll Free: 855-PENNSAF LOCATION OF PROPOSED

More information

Rainscreen Gaps in Exterior Walls

Rainscreen Gaps in Exterior Walls PHRC Webinar Series Tuesday, September 13 @ 1pm Rainscreen Gaps in Exterior Walls Brian Wolfgang Housing Systems Specialist Pennsylvania Housing Research Center 219 Sackett Building University Park, PA

More information

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866) TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Light Gauge Steel Engineers Association Washington, D.C. 20005 Toll Free (866) 465-4732 www.lgsea.com DESIGN OF BY-PASS SLIP CONNECTORS IN COLD-FORMED

More information

Brick Veneer / Wood Stud Walls

Brick Veneer / Wood Stud Walls TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 28 November 2012 Brick Veneer / Wood Stud Walls Abstract: This Technical Note deals

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

THE SUPERIOR ROOF & WALL SYSTEMS ROOF WALL & HEADER SYSTEM

THE SUPERIOR ROOF & WALL SYSTEMS ROOF WALL & HEADER SYSTEM ROOF & WALL SYSTEMS "After 37 years experience, over 3,000 homes, I spent 2 years researching the market for affordable, energy efficient products for the emerging wave of "green housing". I use the Ray-Core

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

Schluter -KERDI-DRAIN

Schluter -KERDI-DRAIN Schluter -RONDEC Finishing and edge-protection profile with a rounded reveal surface. Schluter -RONDEC is a finishing and edge-protection profile for tiled edges and outside corners of tiled surfaces.

More information

RB Appendix R (New)

RB Appendix R (New) RB473 13 Appendix R (New) Proponent: Martin Hammer, representing: California Straw Building Association, Colorado Straw Bale Association, Straw Bale Construction Association New Mexico, Ontario Straw Bale

More information

Concrete Block Machines Typical Fixed Block Machine

Concrete Block Machines Typical Fixed Block Machine SEAOG 2016 Masonry Workshop Concrete Masonry Units and Terminology Concrete Masonry in Georgia Georgia World Congress Center Reference: Inspector s Handbook Masonry Institute of America Roy Keck, FACI

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC. 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3720 Reissued 09/2016 This report is subject to renewal 09/2018. DIVISION: 09 00 00 FINISHES

More information

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT 1 East Franklin Street Phone: 301-790-4163 Third Floor Hagerstown, MD 21740 Fax: 301-791-2650 BUILDING PERMIT APPLICATION FOR RESIDENTIAL ACCESSORY

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4073 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

Detail Set: Thermax Wall System Masonry

Detail Set: Thermax Wall System Masonry Dow Building Solutions Detail Set: Thermax Wall System Masonry This detail set outlines the masonry guidelines for design using the THERMAX Wall System, focusing around attachment of masonry façades and

More information

Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES

Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES Prefabricated Light Weight Steel Structures WALLS, FLOORS, TRUSSES www.psiincusa.com 14869 Persistence Drive Woodbridge, Virginia 22191 Phone: 703.550.1466 Fax: 703-550-0486 Systems Guide Introduction

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00

More information

ISO Types 1-6: Construction Code Descriptions

ISO Types 1-6: Construction Code Descriptions ISO 1 Frame (combustible walls and/or roof) Typically RMS Class 1 Wood frame walls, floors, and roof deck Brick Veneer, wood/hardiplank siding, stucco cladding Wood frame roof with wood decking and typical

More information

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary

More information

Project Address: Name of Person Completing Form:

Project Address: Name of Person Completing Form: Statement of Inspections This form is provided as a way to list aspects of the project that require special inspection and testing in accordance with IBC Sections 107.1, 1704, and 1705 and define duties

More information

HIGHLANDVIEW CEMETERY CHAPEL

HIGHLANDVIEW CEMETERY CHAPEL HIGHLANDVIEW CEMETERY CHAPEL CONTACT: Ferris State University Small Town Studio Christopher Cosper, AIA, LEED, AP, Assistant Professor cosperc@ferris.edu 23.59.33 Sheet List Sheet Name Sheet # COVER A00

More information

Steps in Building a Shed

Steps in Building a Shed Steps in Building a Shed The design and location of your new shed will depend on how it will be used - a shed for storing tools will be much simpler than one you intend to use as a small shop. For example,

More information

STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804

STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804 STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION PROJECT #: CAP 1804 FRANCONIA NOTCH STATE PARK FRANCONIA, NEW HAMPSHIRE BID SET 8/4/2017 DRAWING LIST:

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2732 Reissued 11/2017 This report is subject to renewal 11/2019. DIVISION: 09 00

More information

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

Cladding Attachment Solutions for Exterior Insulated Commercial Walls Cladding Attachment Solutions for Exterior Insulated Commercial Walls By Graham Finch, Dipl.T, MASc, P.Eng. & James Higgins, Dipl.T. No. 011 December 2015 rdh.com 1 Introduction The use of exterior insulation

More information

Differences between EnCon Insulated Precast and EIFS

Differences between EnCon Insulated Precast and EIFS Differences between EnCon Cover Differences between EnCon EnCon produces a number of different insulated precast concrete products. They range from Insulated Wall panels, Styrocore Insulated Wall Panels,

More information

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2214 Reissued 08/2017 This report is subject to renewal 07/2019. DIVISION: 09 00

More information

think eco WOOD BOARD Bahan Binaan KELASʻOʼ

think eco WOOD BOARD Bahan Binaan KELASʻOʼ think eco BOARD Bahan Binaan KELASʻOʼ Bahan Binaan KELASʻOʼ BS 476 : PART 6 : 1989 + A1 :2009 SustainableArchitecturalSolutions Green Sustainable Building Products or eco-friendly products refer to building

More information