- Elijah Jordan
- 6 years ago
- Views:
Transcription
1 PEER/CSSC Tall Building Design Case Study Building #1 J. Andrew Fry John Hooper Ron Klemencic Magnusson Klemencic Associates
2 Building Information Located in Los Angeles 42-Story 410 ft Tall 108 ft X 107 ft Plan Dimensions Core Wall System Approximate Period: 5 Sec
3 Tower Plan
4 Tower and Core Wall Isometric
5 Two Designs Performed Design #1A Prescriptive provisions of the 2006 IBC All prescriptive provisions observed except height limit Capacity design principles were not employed
6 Two Designs Performed Design #1B Performance-Based Seismic Design conforming to the 2008 LATBSDC Seismic Design Criteria, with the following two exceptions: 25-year EQ used in Serviceability Analysis 2.5 % viscous damping Only a limited number of elements allowed to reach 120 % of their capacity The minimum base shear waived Minimum strength provided by 25-year EQ and Wind
7 Design #1A Wind Design Criteria Basic Wind Speed: 85 mph Exposure: B Occupancy Category II: I W = 1.0 Topographic Factor (K ZT ): 1.0
8 Design #1A Seismic Design Criteria Occupancy Category II: I e = 1.0 Mapped Spectral Accelerations: S s = 2.147; S 1 = Site Class C F a = 1.0; F v = 1.3 Spectral Response Coefficients: S DS = 1.145; S D1 = Seismic Design Category: D
9 Design #1A Seismic Design Criteria Lateral System: Building Frame, Special Reinforced Concrete Shear Walls, R = 6 T code = 2.55 sec (based on H = 410 ) C s = (Eq governs) V = 0.85C s W (w/ RSA scaling) V = 4,565 kips
10 Design #1A Results Core Wall Thickness Grade Level 25 = 24 inches Level 25 Roof = 21 inches Building Modes: Mode 1 T X = 6.7 Sec Mode 2 T Y = 4.8 Sec Mode 3 T Z = 2.6 Sec
11 Design #1A Results Shears at Grade: Seismic V X = 4,581k V Y = 4,581k Wind V X = 2,080k V Y = 2,080k Overturning Moment at Grade Seismic M Y = 587,000 k-ft M X = 697,000 k-ft Wind Maximum Story Drifts: Δ X = 1.1% Δ Y = 0.8% M Y = 540,000 k-ft M X = 513,000 k-ft
12 Design #1B Performance Objectives 25-yr EQ: Serviceability: Structure to remain essentially elastic with only minor damage MCE: Collapse Prevention: Extensive structural damage; repairs are required and may not be economically feasible
13 Design #1B Serviceability Model 3-D Model using ETABS Elastic RSA Model Included Slab Outriggers
14 Design #1B Serviceability Acceptance Criteria Story Drift Limitation: 0.5 percent Coupling Beams Shear: Remain Essentially Elastic Core Wall Flexure: Remain elastic Core Wall Shear: Remain elastic Slab Outriggers: Columns: Remain essentially Elastic Remain elastic
15 Design #1B MCE Model 3-D model using CSI Perform-3D Modeled as inelastic: Coupling beams Core wall flexural behavior Slab beams Modeled as elastic: Core wall shear behavior Diaphragm slabs Columns Basement walls Model extended to mat
16 Design #1B MCE Acceptance Criteria Story Drift: 3 % Coupling Beam Rotation: 0.06 radian limit Core Wall Reinforcement Axial Strain: Tensile strain = 0.05 Compression strain = 0.02 Core Wall Concrete Axial Strain: Fully Confined Concrete Compression Strain = Core Wall Shear: Post-Analysis Verification Performed
17 Design #1B Seismic Hazard Spectra
18 Design #1B Results Core Wall Thickness Grade Level 13 = 28 & 32 inches Level 13 Level 31 = 24 inches Level 31 Roof = 21 inches Building Modes: Mode 1--T X = 4.2 Sec Mode 2--T Y = 3.1 Sec Mode 3--T Z = 1.6 Sec
19 Design #1B Serviceability Results
20 Design #1B Serviceability Results
21 MCE Results: Building Story Drift
22 MCE Results: Core Wall Shear
23 MCE Results: Core Overturning Moment
24 MCE Results: Coupling Beam Rotations
25 MCE Results: Core Wall Tensile Strains
26 Case Study #1 Observations Core wall shear is the governing design parameter & governs wall thickness Walls thicker for Design #1B versus #1A T #1B = at base & 21 at roof T #1A = 24 at base & 21 at roof Serviceability Design governed over Wind Design V Servicability = 5,013 and 6,018 kips = 1,816 and 1,918 kips V Wind Design
27 Case Study #1 Observations Serviceability Design of #1B larger than Design of #1A V #1B = 5,013 and 6,018 kips V #1A = 4,581 and 4,581 kips MCE Shear Design of #1B larger than Design of #1A V #1B = 12,556 and 13,409 kips V #1A = 4,581 and 4,581 kips Tensile Strains are low, but yielding occurs over height of core wall Spectral Matching reduced dispersion in the results
Application of Buckling Restrained Braces in a 50-Storey Building
ctbuh.org/papers Title: Authors: Subject: Keywords: Application of Buckling Restrained Braces in a 50-Storey Building Jose A. Sy, SY2 + Associates, Inc. Naveed Anwar, Asian Institute of Technology Thaung
More informationREINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION
1NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 1-, 1 Anchorage, Alaska REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION
More informationDesign Example 2 Reinforced Concrete Wall with Coupling Beams
Design Example 2 Reinforced Concrete Wall with Coupling Beams OVERVIEW The structure in this design example is a six story office building with reinforced concrete walls as its seismic force resisting
More information3.5 Tier 1 Analysis Overview Seismic Shear Forces
Chapter 3.0 - Screening Phase (Tier ) 3.5 Tier Analysis 3.5. Overview Analyses performed as part of Tier of the Evaluation Process are limited to Quick Checks. Quick Checks shall be used to calculate the
More informationCouncil on Tall Buildings. and Urban Habitat
Performance-Based Seismic Design: International Practices Professor Guo-Qiang Li, Tongji University, Shanghai, China Ron Klemencic, President Magnusson Klemencic Associates, USA CTBUH Seismic Workshop
More informationOPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS (PUSH OVER ANALYSIS)
OPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS 2013.1.5 (PUSH OVER ANALYSIS) Karthik.N.M 1, N.Jayaramappa 2 1 Assistant Professor, Dept. of Civil Engineering Chikka Muniyappa
More informationPERFORMANCE-BASED SEISMIC DESIGN OF TALL BUILDINGS IN THE U.S.
PERFORMANCE-BASED SEISMIC DESIGN OF TALL BUILDINGS IN THE U.S. Jack P. Moehle Pacific Earthquake Engineering Research Centre, UC Berkeley, USA ABSTRACT: Building codes in the United States contain prescriptive
More informationMulti performance option in direct displacement based design
Multi performance option in direct displacement based design Ima Muljati 1,*, Yonatan, and Adrian Hartono 1 Civil Engineering Department, Petra Christian University, Surabaya, Indonesia Alumni of Civil
More informationPerformance Based Seismic Design of Reinforced Concrete Building
Open Journal of Civil Engineering, 2016, 6, 188-194 Published Online March 2016 in SciRes. http://www.scirp.org/journal/ojce http://dx.doi.org/10.4236/ojce.2016.62017 Performance Based Seismic Design of
More informationSEAU 5 th Annual Education Conference 1. ASCE Concrete Provisions. Concrete Provisions. Concrete Strengths. Robert Pekelnicky, PE, SE
ASCE 41-13 Concrete Provisions Robert Pekelnicky, PE, SE Principal, Degenkolb Engineers Chair, ASCE 41 Committee* *The view expressed represent those of the author, not the standard s committee as a whole.
More informationDESIGN OF HIGH-RISE CORE-WALL BUILDINGS: A CANADIAN PERSPECTIVE
DESIGN OF HIGH-RISE CORE-WALL BUILDINGS: A CANADIAN PERSPECTIVE Perry Adebar Professor, Dept. of Civil Engineering, The University of British Columbia, Vancouver, Canada Email: adebar@civil.ubc.ca ABSTRACT
More informationSpan Length Effect on Seismic Demand on Column Splices in Steel Moment Resisting Frames
Span Length Effect on Seismic Demand on Column Splices in Steel Moment Resisting Frames B. Akbas Gebze Institute of Technology, Turkey Blank Line 9 pt O. Seker Yildiz Technical University, Turkey Blank
More informationAn Alternative Procedure for Seismic Analysis and Design of Tall Buildings
An Alternative Procedure for Seismic Analysis and Design of Tall Buildings F. Naeim, L. D. Carpenter, T. Ghodsi, G. C. Hart, M. Lew, M. Mehrain, T. A. Sabol and J. W. Wallace John A. Martin & Associates
More informationPEER Tall Building Seismic Design. Purpose of Analysis. Service Level and MCE Analysis. Ronald O. Hamburger
PEER Tall Building Seismic Design Guidelines Service Level and MCE Analysis Ronald O. Hamburger Senior Principal Simpson Gumpertz & Heger Inc. SEAONC April 19, 2010 Purpose of Analysis Demonstrate that
More informationSeismic Performance and Design of Linked Column Frame System (LCF)
Seismic Performance and Design of Linked Column Frame System (LCF) M. Malakoutian & J.W. Berman Department of Civil and Environmental Engineering, University of Washington, Seattle, WA, USA P. Dusicka
More informationEvaluation of the ASCE 7-05 Standard for Dual Systems: Response History Analysis of a Tall Buckling-Restrained Braced Frame Dual System
Evaluation of the ASCE 7-5 Standard for Dual Systems: Response History Analysis of a Tall Buckling-Restrained Braced Frame Dual System L. J. Aukeman 1 and P. Laursen 1 Graduate Student, Department of Architectural
More informationDeformation Capacity of RC Structural Walls without Special Boundary Element Detailing
Proceedings of the Tenth Pacific Conference on Earthquake Engineering Building an Earthquake-Resilient Pacific 6-8 November 2015, Sydney, Australia Deformation Capacity of RC Structural Walls without Special
More informationSEISMIC LOSS ASSESSMENT OF EXISTING TALL STELL BUILDINGS IN LOS ANGELES
SECED 2015 Conference: Earthquake Risk and Engineering towards a Resilient World 9-10 July 2015, Cambridge UK SEISMIC LOSS ASSESSMENT OF EXISTING TALL STELL BUILDINGS IN LOS ANGELES Aysegul GOGUS 1 Huseyin
More information4.2 Tier 2 Analysis General Analysis Procedures for LSP & LDP
4.2 Tier 2 Analysis 4.2.1 General Four analysis procedures are provided in this section: Linear Static Procedure (LSP), Linear Dynamic Procedure (LDP), Special Procedure, and Procedure for Nonstructural
More informationSEISMIC DEISGN GUIDELINES FOR TALL BUILDINGS. Developed by the. Pacific Earthquake Engineering Research Center. Under its. Tall Buildings Initiative
SEISMIC DEISGN GUIDELINES FOR TALL BUILDINGS Developed by the Pacific Earthquake Engineering Research Center Under its Tall Buildings Initiative July 00 SEISMIC DESIGN GUIDELINES FOR TALL BUILDINGS Dr.
More information22. DESIGN OF STEEL BRACED FRAMES Eccentrically Braced Steel Frames
22. DESIGN OF STEEL BRACED FRAMES 22.1 Eccentrically Braced Steel Frames Objective is to dissipate energy in the shear or moment links and to protect the remainder of the frame from inelastic action, including
More informationPEER Tall Building Seismic Design Guidelines
PEER Tall Building Seismic Design Guidelines Analysis, Modeling and Acceptance Criteria Ronald O. Hamburger Senior Principal Simpson Gumpertz & Heger Inc. SEAW November 30, 2010 Purpose of Analysis Demonstrate
More informationCouncil on Tall Buildings
Structure Design of Sino Steel (Tianjin) International Plaza Xueyi Fu, Group Chief Engineer, China Construction Design International 1 1 Brief of Project 2 Location: Tianjin Xiangluowan Business District
More informationTHE STUDY ON BEHAVIOUR OF OUTRIGGERS FOR TALL BUILDINGS SUBJECTED TO LATERAL LOAD
THE STUDY ON BEHAVIOUR OF OUTRIGGERS FOR TALL BUILDINGS SUBJECTED TO LATERAL LOAD Chethan Patel Y G 1, Kiran Kuldeep K N 2 1PG Student, Department of civil engineering SJBIT, Bengaluru 2Assistant Professor.
More informationNonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale
Nonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale Abstract: The applicability of the SAP2000 software for the nonlinear pushover
More informationATC-72 of the PEER Tall Buildings Initiative: Interim Guidelines on Modeling and Acceptance Criteria for Seismic Design and Analysis of Tall Buildings
SEAOC 2008 CONVENTION PROCEEDINGS ATC-72 of the PEER Tall Buildings Initiative: Interim Guidelines on Modeling and Acceptance Criteria for Seismic Design and Analysis of Tall Buildings James O. Malley,
More informationAvailable at ISSN
Page No.149 Available at www.ijcasonline.com ISSN 2349 0594 International Journal of Modern Chemistry and Applied Science International Journal of Modern Chemistry and Applied Science 2015, 2(3), 148-152
More informationRequirements for Foundations on Liquefiable Sites
Requirements for Foundations on Liquefiable Sites Robert Bachman, S.E. R. E. Bachman Consulting Structural Engineers Laguna Niguel, CA 1 Issue Team and ASCE 7 Contributing Members Evolved and Improved
More informationHYBRID MOMENT RESISTING STEEL FRAMES
HYBRID MOMENT RESISTING STEEL FRAMES Finley A. Charney 1 and Ozgur Atlayan 2 1 Associate Professor, Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 2461, USA 2 Graduate
More informationEffect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis
Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis Zasiah Tafheem 1, A.S.M Rubaiat Nahid 2, Tanzeelur Rahman
More informationSEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS
SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS Frank Devine, 1 Omri Olund, 2 Ken Elwood 3 and Perry Adebar 4 1 Graduate Student, Dept. of Civil Engineering, University
More informationPEER/ATC-72-1 Modeling and Acceptance Criteria for. Overview. Jon A. Heintz
PEER/ATC-72-1 Modeling and Acceptance Criteria for Tall Buildings Jon A. Heintz Director of Projects Applied Technology Council Redwood City, California SEAONC April 19, 2011 Overview Introduce the PEER/ATC-72-1
More informationSEISMIC ISOLATION OF THE NUNOA CAPITAL BUILDING, THE TALLEST BASE ISOLATED BUILDING IN THE AMERICAS
Paper N 2070 Registration Code: S-S1464360046 SEISMIC ISOLATION OF THE NUNOA CAPITAL BUILDING, THE TALLEST BASE ISOLATED BUILDING IN THE AMERICAS R. Lagos (1), R. Boroschek (2), R. Retamales (3), M. Lafontaine
More informationStructural Technical Report 3 Lateral System Analysis and Confirmation Design
Structural Technical Report 3 Lateral System Analysis and Confirmation Design James Wilson Structural Option AE 481W Senior Thesis The Pennsylvania State University Faculty Consultant: Professor M. Kevin
More informationSeismic Base Isolation of the Nunoa Capital Building, the Tallest Base Isolated Residential Building in the Americas
13th World Conference on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures - commemorating JSSI 20 th Anniversary - September 24-27 2013 Sendai Japan Paper No. # 160 Seismic
More informationINTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011
INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011 Copyright 2010 All rights reserved Integrated Publishing services Research article ISSN 0976 4399 Solution of Shear Wall Location
More informationGlobal Village Rochester Institute of Technology Rochester, New York
Presentation Outline Welcome Introduction Architecture Existing Structure Problem Statement Arch. Breadth Structural Depth Conclusion Questions Global Village Rochester Institute of Technology Rochester,
More informationSeismic performance assessment of reinforced concrete buildings using pushover analysis
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 2278-1684 Volume 5, Issue 1 (Jan. - Feb. 2013), PP 44-49 Seismic performance assessment of reinforced concrete buildings using pushover
More informationDamage-control Seismic Design of Moment-resisting RC Frame Buildings
Damage-control Seismic Design of Moment-resisting RC Frame Buildings Huanun Jiang* 1, Bo Fu 2 and Linzhi Chen 3 1 Professor, State Key Laboratory of Disaster Reduction in Civil Engineering, Tongi University,
More informationCouncil on Tall Buildings. and Urban Habitat ADVANCES IN SEISMIC DESIGN AND CONSTRUCTION IN INDONESIA. CTBUH 2014 Shangai Conference
Davy Sukamta Principal, Davy Sukamta & Partners Structural Engineers President,Indonesian Society of Civil&Structural Engineers ADVANCES IN SEISMIC DESIGN AND CONSTRUCTION IN INDONESIA Recent major earthquakes,
More informationPioneering China s Tallest: Form and Structure of the Ping An Finance Ce nter
Pioneering China s Tallest: Form and Structure of the Ping An Finance Center David Malott, Director, KPF Dennis Poon, Vice Chairman, Thornton Tomasetti 领先中国之巅 : 平安金融中心的形式与结构 David Malott, Director, KPF
More informationINTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK SPECIAL ISSUE FOR NATIONAL LEVEL CONFERENCE "SUSTAINABLE TECHNOLOGIES IN CIVIL
More informationPEER Tall Building Seismic Design Guidelines
PEER Tall Building Seismic Design Guidelines Ronald O. Hamburger Senior Principal Simpson Gumpertz & Heger Inc. Jack P. Moehle University of California at Berkeley PEER Annual Meeting October 15, 2009
More informationSeismic Assessment of an RC Building Using Pushover Analysis
Engineering, Technology & Applied Science Research Vol. 4, No. 3, 014, 631-635 631 Seismic Assessment of an RC Building Using Pushover Analysis Riza Ainul Hakim ainul7@yahoo.com Mohammed Sohaib Alama sohaib.alama@hotmail.com
More informationR. J. McNamara, S.E.
USE OF MOTION AMPLIFICATION DEVICES AND FLUID DAMPERS TO REDUCE THE WIND INDUCED RESPONSE OF TALL BUILDINGS by R. J. McNamara, S.E. McNamara/Salvia, Inc. Boston, MA 02110 USE OF MOTION AMPLIFICATION DEVICES
More informationPERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)
PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140) *A. Ahmed 1, K. H. Tan 1 1 Department of Civil and Environmental Engineering National University of Singapore, Singapore,
More informationSeismic Behavior, Analysis and
UNIVERSITY of ILLINOIS NEES Small-Group Research Project: Seismic Behavior, Analysis and Design of Complex Wall Systems (NSF Grant CMMI-0421577) Laura Lowes, Dawn Lehman, Jake Turgeon, Anna Birely, Joshua
More informationMEMORIAL SLOAN-KETTERING CANCER CENTER
MEMORIAL SLOAN-KETTERING CANCER CENTER SENIOR THESIS PRESENTATION THE PENNSLYVANIA STATE UNIVERSITY DEPARTMENT OF ARCHITECTURAL ENGINEERING PRESENTATION OUTLINE INTRODUCTION BUILDING DESCRIPTION EXISTING
More informationEVALUATION OF COLLECTOR DESIGN FOR CONCRETE DIAPHRAGMS
10NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska EVALUATION OF COLLECTOR DESIGN FOR CONCRETE DIAPHRAGMS J. S. LeGrue
More informationIJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online):
IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online): 2321-0613 Seismic Response of Tall Irregular Buildings under Influence of Torsion Lohith Kumar
More informationOne-Way Wide Module Joist Concrete Floor Design
One-Way Wide Module Joist Concrete Floor Design A 1 3 4 30'-0" 30'-0" 30'-0" 3' B 3' C 3' D 3' E 4" 4" (typ.) 3' F 0" 0" (typ.) Figure 1 One-Way Wide Module Joist Concrete Floor Framing System 1 Overview
More informationPERFORMANCE OF LATERAL SYSTEMS ON TALL BUILDINGS
International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 6, November-December 2016, pp. 550 557, Article ID: IJCIET_07_06_061 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=6
More informationHOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013
HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013 HOTEL N.E.U.S. BUILDING INFORMATION SITE Located in the Northeast United States
More informationIT4 Shear Wall Design. Update November 30, 2016
IT4 Shear Wall Design Update November 30, 2016 Voting Members Michel Bruneau, University of Buffalo, Buffalo, NY Kelly Cobeen, Wiss, Janney, Elstner, Emeryville, CA Jason Collins, PCS Structural Solutions,
More informationON DRIFT LIMITS ASSOCIATED WITH DIFFERENT DAMAGE LEVELS. Ahmed GHOBARAH 1 ABSTRACT
ON DRIFT LIMITS ASSOCIATED WITH DIFFERENT DAMAGE LEVELS Ahmed GHOBARAH ABSTRACT Performance objectives in performance-based design procedures have been described in several ways according to the operational
More informationThe Tall Buildings Initiative
SEAOC 2007 CONVENTION PROCEEDINGS The Tall Buildings Initiative Jack Moehle, PhD, PE; Yousef Bozorgnia, PhD, PE; and T.Y. Yang, PhD Pacific Earthquake Engineering Research Center University of California,
More informationHOW HAVE CHANGES IN BUILDING CODE PROVISIONS FOR REINFORCED CONCRETE FRAME STRUCTURES IMPROVED SEISMIC SAFETY? ABSTRACT
HOW HAVE CHANGES IN BUILDING CODE PROVISIONS FOR REINFORCED CONCRETE FRAME STRUCTURES IMPROVED SEISMIC SAFETY? A. B. Liel, C. B. Haselton 2, and G. G. Deierlein 3 ABSTRACT This study provides an analytical
More informationNATIONAL HARBOR BUILDING M OXON HILL, MARYLAND. Ryan Sarazen Structural Option Technical Report 3 Faculty Consultant: Dr.
NATIONAL HARBOR BUILDING M OXON HILL, MARYLAND Ryan Sarazen Structural Option Technical Report 3 Faculty Consultant: Dr. Andres Lepage Table of Contents Executive Summary.. 3 Structural Systems Overview...
More informationRESEARCH PROJECT AT UNIVERSITY OF NEVADA, RENO
RESEARCH PROJECT AT UNIVERSITY OF NEVADA, RENO QUARTERLY REPORT October 1, 2016 to December 31, 2016 Period Year 1 Project Development and Seismic Evaluation of Pier Systems w/ Pocket Connections and Square
More informationThis point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:
Chapter II. REVIEW OF PREVIOUS RESEARCH II.1. Introduction: The purpose of this chapter is to review first the basic concepts for earthquake engineering. It is not intended to review the basic concepts
More informationEffect of Column Shortening on the Behavior of Tubular Structures
Indian Journal of Science and Technology, Vol 8(36), DOI: 1.17485/ijst/215/v8i36/87533, December 215 ISSN (Print) : 974-6846 ISSN (Online) : 974-5645 Effect of Column Shortening on the Behavior of Tubular
More informationRESEARCH PROJECT AT UNIVERSITY OF NEVADA, RENO
RESEARCH PROJECT AT UNIVERSITY OF NEVADA, RENO QUARTERLY REPORT Oct. 1, 2015 to December 31, 2015 Period Submitted by M. Saiidi, A. Itani, and A. Mohebbi Department of Civil and Environmental Engineering
More informationSponsored by The Boston Association of Structural Engineers and the Structural Engineers Association of Massachusetts
Commonwealth of Massachusetts State Building Code 780-CMR 9 th Edition Renovation of Existing Buildings Using The International Existing Building Code IEBC 2015 with Massachusetts Amendments Sponsored
More informationSEISMIC SHEAR FORCE MAGNIFICATION IN RC COUPLED WALL SYSTEMS, DESIGNED ACCORDING TO EUROCODE 8
SEISMIC SHEAR FORCE MAGNIFICATION IN RC COUPLED WALL SYSTEMS, DESIGNED ACCORDING TO EUROCODE 8 Klemen REJEC 1, Tatjana ISAKOVIĆ 2 and Matej FISCHINGER 3 ABSTRACT The same (Keintzel s) magnification factor
More informationBahram Marabi* & Abdul Kadir Marsono
Malaysian Journal of Civil Engineering 28 Special Issue (3):163-179(2016) SEPKA 2016 A NUMERICAL AND ANALYTICAL STUDY ON OPTIMIZATION AND EFFICIENCY OF STRUCTURAL FORMS BY TWO-OUTRIGGER IN TALL BUILDINGS
More informationMarina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle
Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle Overall Information Location: Singapore Date of Completion: 2010 Cost: $5.7 billion Architect: Moshe Safdie Executive Architect: Aedas, Pte
More informationPerformance-Based Seismic Design for Tall Buildings
CTBUH Technical Guides Performance-Based Seismic Design for Tall Buildings An output of the CTBUH Performance-Based Seismic Design Working Group Ramin Golesorkhi, Leonard Joseph, Ron Klemencic, David Shook
More informationApplication of Pushover Analysis for Evaluating Seismic Performance of RC Building
Application of Pushover Analysis for Evaluating Seismic Performance of RC Building Riza Ainul Hakim* MSc Student in Civil Engineering, Faculty of Engineering, King Abdul-Aziz University, Jeddah, KSA Mohammed
More informationSeismic Analysis of Monolithic Coupling Beams of Symmetrical Coupled Shear Wall System
Research Article International Journal of Current Engineering and Technology ISSN 2277-4106 2012 INPRESSCO. All Rights Reserved. Available at http://inpressco.com/category/ijcet Seismic Analysis of Monolithic
More informationPERFORMANCE- BASED SEISMIC DESIGN OF A BUILDING
PERFORMANCE- BASED SEISMIC DESIGN OF A BUILDING Jitendra Awasthi 1, Goutam Ghosh 2, P.K.Mehta 3 1 Ph.D. (Research Scholar) Civil Engineering Department, MNNIT Allahabad 2 Assistant Professor, Civil Engineering
More informationP-DELTA EFFECTS ON TALL RC FRAME-WALL BUILDINGS
P-DELTA EFFECTS ON TALL RC FRAME-WALL BUILDINGS T.J. Sullivan 1, T.H. Pham 2 and G.M. Calvi 3 1 Assistant Professor, Dept. of Structural Mechanics, Università degli studi di Pavia, Pavia, Italy 2 Consulting
More informationSeismic evaluation of Hybrid steel frames with different patterns of semi-rigid connection
Seismic evaluation of Hybrid steel frames with different patterns of semi-rigid connection M. Ghassemieh 1) and N. Vahedi 2) 1) School of Civil Engineering, University of Tehran, Tehran, Iran 2) MSc. Student
More informationCE 3150 Reinforced Concrete Design Design Project
Problem Description For this design project you will work in your project groups to complete a partial design of an office building. Specifically, you will design and fully detail three components: 1.
More informationLATERAL LOADS ON BRICK VENEER RESIDENTIAL STRUCTURES
LATERAL LOADS ON BRICK VENEER RESIDENTIAL STRUCTURES W. Mark McGinley 1, PhD, PE and Eric N. Johnson 2, PE ABSTRACT In North American residential construction, brick veneer is typically used as a cladding
More informationSEISMIC DESIGN REQUIREMENTS FOR REINFORCED CONCRETE BUILDINGS
SEISMIC DESIGN REQUIREMENTS FOR REINFORCED CONCRETE BUILDINGS MODEL BUILDING CODES A model building code is a document containing standardized building requirements applicable throughout the United States.
More informationNONLINEAR STATIC ANALYSIS OF R.C.C. FRAMES (Software Implementation ETABS 9.7)
NONLINEAR STATIC ANALYSIS OF R.C.C. FRAMES (Software Implementation ETABS 9.7) Mrugesh D. Shah M.E Structure student, B.V.M Engineering College Abstract:- Nonlinear static analysis is an iterative procedure
More informationNonlinear Finite Element Modeling & Simulation
Full-Scale Structural and Nonstructural Building System Performance during Earthquakes & Post-Earthquake Fire A Joint Venture between Academe, Industry and Government Nonlinear Finite Element Modeling
More informationEmbassy Suites Hotel Springfield, Virginia. Dominick Lovallo Structural Option AE Senior Thesis Thesis Advisor: Dr.
Embassy Suites Hotel Springfield, Virginia Dominick Lovallo Structural Option AE Senior Thesis 2012-2013 Thesis Advisor: Dr. Hanagan Lobby Rendering Presentation Overview Proposed Building Presentation
More informationPile to Slab Bridge Connections
Pile to Slab Bridge Connections Mohamed I. Ayoub 1, David H. Sanders 2 and Ahmed Ibrahim 3 Abstract Slab bridges are a common bridge type, where the pile extends directly from the ground to the superstructure.
More informationPricewaterhouseCoopers Building Oslo, Norway
PricewaterhouseCoopers Building Oslo, Norway James Wilson Structural Option Senior Thesis Presentation 2009 The Pennsylvania State University Location Bjørvika B10 A Oslo, Norway BARCODE Building Data
More informationTrends in the Seismic Design Provisions of U.S. Building Codes
Trends in the Seismic Design Provisions of U.S. Building Codes Seismic design provisions in building codes of the United States have undergone profound and farreaching changes in recent years. This paper
More informationctbuh.org/papers Proposed Methodology To Determine Seismic Performance Factors For Steel Diagrid Framed Systems
ctbuh.org/papers Title: Authors: Subjects: Keywords: Proposed Methodology To Determine Seismic Performance Factors For Steel Diagrid Framed Systems William Baker, Partner, Skidmore, Owings & Merrill LLP
More informationCHAPTER 2: CONCRETE POST-TENSIONED REDESIGN
CHAPTER 2: CONCRETE POST-TENSIONED REDESIGN 2.1 INTRODUCTION The basis for the structural depth of this report was a switch from composite steel beam and concrete floor system to a concrete post-tensioned
More informationNONLINEAR PERFORMANCE OF A TEN-STORY REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME (SMRF)
NONLINEAR PERFORMANCE OF A TEN-STORY REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME (SMRF) Houssam Mohammad Agha, Li Yingmin, Oday Asal Salih and A ssim Al-Jbori Doctoral Candidate, College of Civil
More informationTechnical Assignment 1 10/8/03
Executive Summary Technical Assignment 1 10/8/03 The is 55 story high-rise condominium being built off the northern Miami coast. The structural design presented in this building is a direct result of its
More informationNear Source Fault Effects on the Performance of Base- Isolated Hospital Building vs. a BRBF Hospital Building
Near Source Fault Effects on the Performance of Base- Isolated Hospital Building vs. a BRBF Hospital Building Badri K. Prasad, S.E., Principal DASSE Design Inc. Oakland, California Troy A. Morgan, Ph.D.,
More informationSHAKE TABLE TESTING OF BRIDGE REINFORCED CONCRETE COLUMNS UNDER COMBINED ACTIONS
SHAKE TABLE TESTING OF BRIDGE REINFORCED CONCRETE COLUMNS UNDER COMBINED ACTIONS Juan G. Arias Acosta, Graduate Student David H. Sanders, Professor and Project PI University of Nevada, Reno NEESR SG 53737
More informationDiaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories
Diaphragms 2 Design Process Diaphragms are the roofs and floors of the upper stories They are assumed to act as a beam (usually a deep beam with substantial shear deformation) Design Process Sheathing
More informationLATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor
LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS Qiang SHEN Graduate Research Assistant Yahya C. KURAMA Assistant Professor University of Notre Dame, Civil Engineering and Geological
More informationEARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS
EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS Jyothi. C. Hawaldar, Dr. D. K. Kulkarni Student, 4 th sem, M.Tech(CADS), Department of Civil
More informationChallenges and Opportunities for the Structural Design of the Jamsil Lotte World Tower
Challenges and Opportunities for the Structural Design of the Jamsil Lotte World Tower Jong-Ho Kim, P.E., CEO & Chairman, LOTTE WORLD TOWER Height 555 m (1,821 ft) Floor Count 123 above ground 6 below
More informationAISC Steel & Timber Research for High-Rise Residential Buildings
AISC Steel & Timber Research for High-Rise Residential Buildings Final Report December 4 th, 2017 SOM Designed Benchmark Concrete Building Skidmore, Owings, and Merrill, LLP 2017 224s Michigan Avenue Suite
More informationDUCTILITY REQUIREMENTS FOR BUILDINGS
DUCTILITY REQUIREMENTS FOR BUILDINGS Prof. P. C. Vasani, Applied Mechanics Department, L. D. College of Engineering, Ahmedabad 380015. profvasani@rediffmail.com Bhumika B. Mehta M. E. CIVIL - (CASAD) Sem
More informationSEISMIC PROVISIONS OF IBC 2006 AND ASCE 7-05
Introduction This paper is meant for people studying for the ARE. Engineers and professors may not like the way some of the ideas are presented. They are meant to help understand the concepts and impacts
More informationSEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS
6 th International Conference on Advanced Composite Materials in Bridges and Structures 6 ième Conférence Internationale sur les matériaux composites d avant-garde pour ponts et charpentes Kingston, Ontario,
More informationRetrofit of an Existing Hospital to Immediate Occupancy Standards. One Year Later. Degenkolb Engineers
Retrofit of an Existing Hospital to Immediate Occupancy Standards One Year Later Degenkolb Engineers R. Jay Love, S.E. Sean McNeil, S.E. Kent Yu, Ph.D, P.E Damaged Hospital Building Designed Designed in
More informationTables with Allowable ASD Seismic Values For Design at R = 6.5. Special Moment Frame MF1-12
Tables with Allowable ASD Seismic Values For Design at R = 6.5 Special Moment Frame MF1-12 Hardy Frames, Inc manufactures and markets pre-fabricated shear wall systems. We have been the innovative leader
More informationSeismic Analysis of Steel Frames with Different Bracings using ETSBS Software.
Seismic Analysis of Steel Frames with Different s using ETSBS Software. Muhammed Tahir Khaleel 1, Dileep Kumar U 2 1M.Tech Student, Dept of Civil Engg, SCEM, Karnataka, India 2Asst Professor, Dept of Civil
More informationIBC 2006 & ASCE 7-05 Structural Provisions. Martin Johnson, SE & Todd Erickson, SE June 14, 2007
IBC 2006 & ASCE 7-05 Structural Provisions Martin Johnson, SE & Todd Erickson, SE June 14, 2007 Schedule of Adoption 2006 IBC, ASCE 7-05 and material standard documents are available now. 2007 CBC will
More informationSeattle Public Library OMA & REX
Seattle Public Library OMA & REX Seattle Public Library / General Information Location: Architects: Structural Engineer: Square Footage: Seattle, Washington OMA & REX Arup & Magnusson Klemencic Associates
More information