1 Construction Report NYSERDA Residential Performance Challenge WELYTOK TOWNHOMES October 2014 Submitted to: NYSERDA 17 Columbia Circle Albany, NY Submitted by: HOMEPIC Team CDH Energy Corp. PO Box 641 Cazenovia, NY And Syracuse Center of Excellence in Energy and Environmental Systems Camroden Associates
2 House Description Mark Welytok of New-Paradigm Developers plans to build nine (9) townhomes on the southern shore of Oneida Lake in the town of Chittenango, NY. Our team helped to develop an energy efficient design for these nine (9) units. The first four (4) units are scheduled for completion in The HomePIC project is supporting the improvements to these one of these first four units. These two-story units have a slab-on-grade foundation with 4 rigid foam under the poured concrete slab. The foundation footings use an Insulated Concrete Form (ICF) wall system that uses 2 of expanded polystyrene (EPS) on each side as forms for the footings. The exterior walls were designed with 2 of exterior rigid foam where possible, with 5½ closed cell spray foam in the framing in other areas. Build Site Figure 1. Aerial View of Building Lot (SOURCE: Bing Maps) Figure 2. Homes Under Construction HomePIC Team 1 October 2014
3 Key construction details are summarized in the following Figures. Table 1 compares the originally proposed improvements to actual implemented features. Table 2 summarizes the costs of the implemented improvements. The floor plan is given below. DOWNSTAIRS UPSTAIRS Figure 3. Floor Plan for East-Side End Unit HomePIC Team 2 October 2014
4 Foundation The foundation construction details include the ICF foundation walls and 4 rigid foam under the concrete slab. The builder installed ½ PEX-Al-PEX tubing in the slab for future radiant floor heating. Figure 4 shows the ICF forms from Fox Blocks partially filled with concrete. Plastic clips inside the blocks maintain the spacing of the foam sides. Rebar is installed vertically and horizontally to provide additional strength. ICF Figure 4. ICF Foundation Walls Figure 5 and Figure 6 show the insulation under the concrete slab. Figure 5 shows the 4 foam board on top of the plastic vapor barrier. Figure 6 shows the installed ½ PEX-Al-PEX tubing for radiant heating on top of the 4 foam and steel reinforcement. HomePIC Team 3 October 2014
5 4 Polystyrene Foam Figure 5. 4" Foam Installed Under the Concrete Slab ½ PEX-Al-PEX Tubing Figure 6. PEX-Al-PEX Tubing Installed for Radiant Floor Heating HomePIC Team 4 October 2014
6 Exterior Walls and Framing The exterior walls have 2 rigid exterior foam with taped seams, spray foam, and other details. Figure 7 shows the 2 rigid foam being installed on the east wall of the structure. This foam was isocyanate panels recycled from a school roof. The foam seams were (supposed to be) sealed with tape for air tightening. Figure 8 shows the open cell spray foam in the exterior walls with exterior rigid foam. Exterior walls without exterior foam have closed cell spray foam installed to provide a thermal and vapor barrier. Figure 7. Start of Installation of 2 Exterior Rigid Foam on East Wall Open Cell Spray Foam on All Exterior Walls with Exterior Foam Figure 8. Open Cell Spray Foam on East Wall HomePIC Team 5 October 2014
7 Figure 9 shows the California corner stud arrangement used in the framing of the exterior walls. This configuration provides access to the end of the framed wall for good insulation with minimal thermal bridging. California Corner Figure 9. Typical California Corner Windows All windows are double hung, vinyl frame, triple glazed, argon filled, and dual low E coated. The U- Factor is 0.21 and the Solar Heat Gain Coefficient (SHGC) is The window rough openings were extended with 2x4 s and ½ rigid foam to build out the opening to the same height as the exterior foam board. The window flanges were then nailed to the 2x4 with ½ foam. Figure 10. Window Specifications HomePIC Team 6 October 2014
8 Ceilings, Rim Joists, and Firewalls Figure 11. Cathedral Ceiling with 7 to 8 of Colsed Cell Spray Foam Spray Foamed Rim Joist Figure 12. North Wall and Rim Joist with Closed Cell Spray Foam HomePIC Team 7 October 2014
9 Closed Cell Spray Foam on Exterior Portion of Common Wall / Firewall Paper Faced Fiberglass Insulation in Adiabatic Portion Common Wall / Firewall Figure 13. Firewall Between Units Figure 14. Firewall Between Units with Bottom Plate Spray Foam Sealed HomePIC Team 8 October 2014
10 Figure 15. Garage Ceiling (closed cell) and Garage Wall (open cell) Figure 16. Closed Cell Spray Foam in Dormers and Walls on Lake-Side HomePIC Team 9 October 2014
11 Figure 17. Cathedral Ceiling and Knee Wall with Closed Cell Spray Foam HomePIC Team 10 October 2014
12 Mechanical Systems The townhouse complex will not have natural gas. Therefore the space and water heating will be done with solar and electric systems. Each unit will have a separate solar hot water tank with electric backup. The tank will be connected to in-floor piping so that solar can also contribute to space heating. Space heating and cooling will be provided by a high performance heat pump such as a Mitsubishi Hyper-heat or Fijitsu RLS series unit. The unit should be a 2 or 2-½ ton unit with a concealed indoor fan unit, such as Mitsubishi Hyper Heat Pump PUZ-HA30NHA2 with PEAD-A30AA4 indoor unit shown below. Figure 18. High Performance Heat Pump With Concealed and Ducted Indoor Unit (from Mitsubishi) The indoor unit can be mounted above the washer/dryer in a drop ceiling with very limited ductwork runs (i.e, under 4 ft) to a few locations: 1. to lake-side master bedroom on the first floor 2. through the wall to main area on first floor 3. through the floor to floor vent in the upstairs loft 4. through the floor to a floor vent in the upstairs study A return grill would open to the main areas of the house. The remaining areas of the house (such as the front bedrooms #2 and #3) would have baseboard electric heat. About 6 kw of baseboard heat would be required. HomePIC Team 11 October 2014
13 Table 1. Recommended Thermal Envelope Details Base Design Improved Design Walls 2x6 Frame and Fiberglass Batt. R19 2 Rigid Foam Insulation on exterior of OSB 2x6 frame, Open Cell Spray Foam in Wall Cavity. ~R33 Lake-Side Walls and Dormers 2x6 Frame and Fiberglass Batt. R19 Closed Cell Spray Foam in Wall Sections w/o Exterior Foam. ~R30 Attic Scissor Truss with 2x4 Bottom Cord 11.5 Fiberglass Batt. R38 Scissor Truss with 2x4 Bottom Cord 16 Cellulose. ~R50 Cathedral/Vaulted Ceiling Foundation Walls and Slab Garage Walls and Ceiling 2x4 Parallel Cord Truss with Fiberglass Batt. R38 Poured concrete. 2 foam board on footer Fiberglass Batt 2x4 Parallel Cord Truss with 7-8 Closed Cell Spray Foam. ~R42 ICF Forms with 2.5 Foam on Each Side of Poured Concrete. 4 Rigid Foam Under Poured Concrete Slab Closed Cell Spray Foam in ceiling Open Cell Spray Foam on exterior walls Windows U=0.31, SHGC=0.35 (double hung) U=0.22, SHGC=0.20 (double hung) Rim/Band Joists 5.5 inches of Fiberglass. R21 Caulked and Spray Foamed. Garage-to-Interior Wall Fiberglass Batt, 2x6 Framing. R19 Blown Bagged Cellulose, 2x6 Framing. R19 Air Tightness 5 ACH50 2 ACH50 Various air sealing and thermal bypass improvements DHW Electric water heater Solar Hot Water System Heating and Cooling 92.5% Efficient Gas Furnace Solar HW tank connected to Radiant Infloor Heating 2 or 2-½ ton Hyper heat pump with some electric baseboard heaters. Ventilation Exhaust Only Ventilation Exhaust Only Ventilation HomePIC Team 12 October 2014
14 Table 2. Summary of Capital Cost Differences HomePIC Team 13 October 2014
15 Energy Performance The enegy use predicted by RemRate for the proposed house design is shown in Table 3. The RemRate model assumed an air-source heat pump with a heating seasonal performance factor (HSPF) of 6.8 Btu/Wh (which equates to a seasonal COP of about 2). Table 3. Summary of Energy Use for Proposed Design Heating (kwh) Cooling (kwh) DHW Load (MMBtu) Lights and Appliances (kwh) Total Electric (kwh) Proposed Energy Use 5,315 1, ,449 12,975 HomePIC Team 14 October 2014
Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process
Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process NC Energy Code Requirements ENERGY STAR and NC Energy Code in Alignment RESNET Standards HERS Index A scoring
More informationDate Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection
Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over
More informationPlan Check & Field Inspection Guide
Plan Check & Field Inspection Guide 1992 MEC, 1993 MEC, and 1995 MEC Inside This Guide Plan Check Field Inspection Plan Check Building plans and specifications must be submitted with each building application
More informationBoulder City NV Prepared by (Print Name) Signature Date
City of Boulder City Community Development Department Building & Safety Division 401 California Avenue Boulder City, NV 89005-2600 702-293-9282 (Main Line) 702-293-9392 (Fax) 2009 International Energy
More informationC H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS
C H A P T E R 3 Completing the Residential Analysis Worksheet The Residential Analysis Worksheet is designed to help the reader in making the preliminary calculations necessary to complete Forms 600A-04,
More informationGreen Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING
Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING WWW.STOPWASTE.ORG New Addition Consider the following green remodeling options in a new addition.
More informationEnergy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort
Please add relevant logo here Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Presented by: Peter J. Arsenault, FAIA, NCARB, LEED-AP Disclaimer: This presentation was developed by
More informationEnergy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES
Energy Code Basics for Residential Buildings Presented by Newport Ventures Course Overview / Introduction 1. Overview of definitions and compliance changes 2. Building envelope requirements including air
More informationQuality Inspection 8618 London Heights San Antonio, TX Phone: (210)
Quality Inspection 8618 London Heights San Antonio, TX 78254 Phone: (210) 240-0476 PRE DRYWALL INSPECTION REPORT Prepared For: DELETED (Name of Client) Concerning: DELETED, San Antonio, TX 78258 (Address
More informationOne and Two Family Additions
One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri
More informationLeast Cost Path to Achieving 50% Reduction in Residential Energy Use (in Heating Climates)
Least Cost Path to Achieving 50% Reduction in Residential Energy Use (in Heating Climates) Jan Harris, X Prize Foundation Michael Blasnik, Blasnik and Associates ABSTRACT This paper describes the findings
More informationTruss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017
Truss Heel Heights and Energy Code Requirements Overview Revised 2/17/2017 SBCA has been the voice of the structural building components industry since 1983, providing educational programs and technical
More informationPERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation
PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation INTRODUCTION As the use of spray polyurethane foam (SPF) insulation is increasing in both
More informationEnergy Efficiency Programs
Program Overviews Efficiency Programs Description Delivery Model Audit Requirement/ Multifamily - Existing Building Efficiency Alliant Services include free energy assessments, rebates for property owners
More informationTable of Contents. Page Title
Page Title Table of Contents 1 Floor plan/ Room utilization 2 Elevation (EAST) 3 Elevation (SOUTH) 4 Elevation (WEST) 5 Elevation (NORTH) 6 Foundation plan details 7 Foundation cross sections A Main grade
More informationNew Hampshire Residential Energy Code
CHAIRMAN STATE OF NEW HAMPSHIRE EXECUTIVE DIRECTOR Thomas B. Getz AND SECRETARY COMMISSIONERS Debra A. Howland Susan S. Geiger TDD Access: Relay NH Nancy Brockway 1-800-735-2964 Tel. (603) 271-2431 FAX
More informationConnecticut 2011 Baseline Study of Single-Family Residential New Construction. Final Report
Connecticut 2011 Baseline Study of Single-Family Residential New Construction Final Report October 1, 2012 Submitted to: Connecticut Energy Efficiency Board Submitted by: Group, Inc. KEMA, Inc. Cadmus
More informationAdministrative Changes
Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings
More informationThe Inspection Process. Waxhaw N.C.
The Inspection Process In Waxhaw N.C. This information is provided by the Waxhaw Enforcement Division to assist you in the progression of your project. Nothing in this document should be considered "Code"
More informationCHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION
Chapter 1: Overview of Energy Efficient Construction 1 CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION Chapter 1 is a quick reference guide that discusses the key components and features of energy
More informationHCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS
HCM-00952 UNIVERSITY OF ALASKA FAIRBANKS UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska INTRODUCTION Special considerations for building in Alaska are recommended that are normally not included
More informationFenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other
This information must be on the drawing documents not attached to plans. The following Compliance statements must be on the drawings: 2009 International Energy Conservation Code Statement of acknowledgement
More informationEarth Advantage New Homes Standard - Points Worksheet 2012 Site Built Residential Oregon. Energy Health Land Materials Water
Earth Advantage New Homes Standard - Points Worksheet 22 Site Built Residential Oregon The Earth Advantage program consists of individual measures that have been evaluated by using the five categories
More informationThe REMOTE Wall System
The REMOTE Wall System Robert Maxwell Alaska Energy Associates October 25 INTRODUCTION Modified PERSIST Residential Construction PERSIST stands for the Pressure Equalized Rain Screen Insulated Structure
More informationCompliance Certificate
REScheck Software Version 4.6.4 Compliance Certificate Project RESIDENCE Energy Code: 2009 IECC Location: Perkasie, Pennsylvania Construction Type: Single-family Project Type: New Construction Conditioned
More informationCERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)
CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8) Builder or Installer Name Builder or Installer Contact Telephone Plan/Permit (Additions or Alterations) Number Compliance Method (Prescriptive)
More informationEdouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com
Edouard Modern Living Made Easy uichomes.com - new construction - 3 stories + full basement - 4 bedrooms - 2.5 baths - 2,380 s.f. call 314.881.2333 or e-mail sales@uicstl.com PLAN NTS DECK 13' 0" X 12'-0"
More informationRadon Vent Pipe System. Labeling Performance Indicators
Section 6 Radon Vent Pipe Labeling Performance Indicators Radon Vent Pipe System Connected after sub-grade system installed Pipe cannot be trapped Provide space in chases Support at each floor level Discharge
More informationChapter 2: Foundation
Chapter 2: Foundation Crawlspace [V502.1.2] [V502.1.2] [V502.1.3] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup
More information1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers
1 Exam Prep Prov Module: 27203-13 Thermal and Moisture Protection Questions and Answers 1. The R-value is a measure of the ability of a material to. A. Resist the passage of moisture B. Resist heat conduction
More informationThermal Characteristics of Single-Family Detached, Single-Family Attached, Low-Rise Multifamily, and Mobile Homes
Appendix B Thermal Characteristics of Single-Family Detached, Single-Family Attached, Low-Rise Multifamily, and Mobile Homes 1975-76 by the National Association of Home Builders Research Foundation, Inc.,
More information10 Steps to Save Energy in Your House
10 Steps to Save Energy in Your House Sealing and insulating your home is one of the most cost-effective ways to make your home more comfortable and energy efficient. You can do it yourself. In this chapter,
More informationBASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)
BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from
More informationAPPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.
Chapter 1 101.1 Title. These regulations shall be known as the North Carolina Energy Conservation Code as approved by the North Carolina Building Code Council on March 11, 2008, to be effective January
More informationInsulating an Existing House
EEM-04452 UNIVERSITY OF ALASKA FAIRBANKS UNIVERSITY OF ALASKA FAIRBANKS Insulating an Existing House Many homeowners would like to stay in their current home, but they have difficulty affording the heating
More informationFiscal Note for 2018 NC Energy Conservation Code and Energy Provisions of 2018 NC Residential Code
Fiscal Note for 2018 NC Energy Conservation Code and Energy Provisions of 2018 NC Residential Code Agency: NC Building Code Council Statute: G.S. 143-136; 143-138 Contact: Impact: Barry Gupton NC Department
More informationQuestar ThermWise Duct Technical Specifications
Questar ThermWise Duct Technical Specifications 1. Introduction and Scope: This document sets forth the specifications for duct sealing and duct insulation in accordance to Questar ThermWise Weatherization
More informationQuick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4
The International Energy Conservation Code (IECC) contains energy-efficiency criteria for new construction, but keeping up with changes to the Code can be challenging. This document highlights the 2009
More informationSlab edge insulation is one of
How to Properly Insulate a Slab Presented by: Mike Turns, Associate Director, PHRC Tuesday, April 10, 2012 1:00 PM www.enrg.psu.edu/phrc 4 Slab edge insulation is one of the most abused details in construction.
More informationAppendix. Home Heating Analysis Worksheet. Introduction. Directions C-1
Home Heating Analysis Worksheet Appendix C Introduction This home energy audit will guide you in calculating the heat loss of your residence. This audit includes heat gains from various sources; Item H
More information2012 CLEAResult All rights reserved. Residential Energy Efficiency
Residential Energy Efficiency Presenter Bio Jaymar Davis, PE, CEM, CLEP, CMVP, CEA Sr. Field Engineering Manager 10 Years experience in energy efficiency Johnson Controls, Kohler Co. Certifications: Licensed
More informationCrawl Space Moisture Control
Crawl Space Moisture Control Crawl space foundations are found in many homes. Typically, these foundation types are equipped with operable vents designed to provide ventilation for moisture control. Unfortunately,
More informationAttached Solar Greenhouse Plans for a solar heated greenhouse attached to your home
Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home Designed and built by New Mexico landscape architect John Mosely for his own Santa Fe home. The solar greenhouse shown
More information2
1 2 3 4 5 Spray foam insulation has outstanding insulation properties when compared to traditional insulation materials. It can be an important tool in designing and installing a well-sealed, energy-efficient
More informationNEW HOMES HOME ENERGY GUIDE
HOME ENERGY GUIDE TECHNIQUES TACTICS & TIPS Construction details that go into a high quality, energy efficient home Ensuring indoor air quality and moisture control Questions to ask the builder Bibliography
More informationApplying for Permits to build a new house in Linn County
Planning & Development Linn County, Iowa Building Division Linn County Building Code Residential Guidelines Single Family Dwellings Page 1 of 4 Applying for Permits to build a new house in Linn County
More informationStructural. Orientation of the Home. Northeast Oklahoma REC s Energy Efficient Tips for Home Builders
Northeast Oklahoma REC s Energy Efficient Tips for Home Builders Structural Orientation of the Home An easy way to maximize a home s energy efficiency is to place it properly on the site in the beginning.
More informationResidential Accessory Structures & Room Additions
Residential Accessory Structures & Room Additions Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email:
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationSeal Harbor Development 1 Nagog Park Acton, MA 01720
Seal Harbor Development 1 Nagog Park Acton, MA 01720 Specifications for Ocean Mist Villages Foundation and Concrete Floors Footings All footings are constructed and poured with 3000 lb mix, continuous
More informationstandard features Power Exhaust Fans w/light - Both Baths GFCI Receptacles Upgrade Light Fixture - Bath 1 Vanity - Per Lav GFCI Receptacles
2017 standard features INTERIOR Cornice w / Full Length Drapes Panels-Main Living Areas only Shaw Moxie Carpet with Pad and Tack Designer Select Congoleum No Wax Vinyl Flooring 8 Flat Ceilings Throughout
More informationTypical Finished Basement Details
Albemarle County, Virginia Typical Finished Basement Details Based on the 2012 Virginia Residential Code Finished basements must be constructed in conformance with these details. For requirements, details
More informationExterior Perspective, East End
Interior Open Plan Private to Public Gradation Obstruction of Open Plan Exterior Perspective, East End University of Texas at Austin s intends to be an adaptable design using solar power as its inspiration.
More information2003 International Residential Building Code
2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less
More informationAir Sealing Opportunities in New Construction
Air Sealing Opportunities in New Construction Matt Braman, Energy Trust of Oregon Bruce Manclark, CLEAResult ABSTRACT Advanced air sealing methods are an integral part of energy-efficient new construction
More informationOpen and Closed Cell Spray Foam Insulation
Open and Closed Cell Spray Foam Insulation Complete Comfort CertaSpray has it covered Comfort starts with thermal performance, but it doesn t end there. Complete Comfort comes in an environment free from
More informationPREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and
PREP + INSULATION HOME ENERGY UPGRADES What every contractor needs to know. Copyright 2012 Advanced Energy. All Rights Reserved 103 HOME ENERGY UPGRADES Prep + Insulation Contents Air sealing is a challenging
More informationLock In Energy Savings For Life
Lock In Energy Savings For Life AN ENVIRONMENTALLY FRIENDLY HOME IS A GREAT BENEFIT FOR YOU, YOUR FAMILY AND THE ENVIRONMENT. TAKE AN ACTIVE ROLE IN HELPING REDUCE GREENHOUSE GASES, THUS SLOWING THE EFFECTS
More informationRetrofit Installer / Shell
Retrofit Installer / Shell Day1 9:00 Introductions, Housekeeping Agenda Weatherization Introduction 101 (PRQ for all WX Competency Designations) 9:30 History of the Weatherization Program Weatherization
More informationWhite Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS
BOULDER CHICAGO NASHVILLE SALT LAKE CITY SAN FRANCISCO SPRINGFIELD, MO WASHINGTON, DC 2540 Frontier Avenue, Suite 100 Boulder, Colorado 80301 303.444.4149 White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO
More informationCOLONIAL PLANS. 708 North Street US Highway Route 1 Houlton, Maine (207)532,2444
COLONIAL PLANS 8US Highway Route 1 Hancock, Maine 04640 1(877)767 0664*(207)667 0664 708 North Street US Highway Route 1 Houlton, Maine 04730 (207)532,2444 DEXTER COLONIAL 28 X 34 1904 SQ. FT. DEXTER COLONIAL
More informationThermal Bridging in Residential Construction
PHRC Webinar Series Tuesday, May 12, 2015 @ 1pm Thermal Bridging in Residential Construction Brian Wolfgang Housing Systems Specialist Pennsylvania Housing Research Center 219 Sackett Building University
More informationENERGY AUDITOR STUDY GUIDE
ENERGY AUDITOR STUDY GUIDE COURSE OVERVIEW The Building Analyst and HERS Rater course is based upon a broad building science curriculum. It presents a solid scientific foundation upon which inspectors
More informationINSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:
OWENS CORNING PRODUCTS What exactly is an insulating system? The answer starts with the role insulation plays in your home. All insulating products are based on a single basic principle: heat moves from
More informationCalifornia Building Envelope Solutions
California Building Envelope Solutions Attics & Walls October 2017 What s New in 2016 Title 24 Attics High Performance Attic New prescriptive requirements Roof deck insulation in many CZs Walls High Performance
More informationRESIDENTIAL CONSTRUCTION New Dwellings and Additions
How to Obtain a Building Permit For RESIDENTIAL CONSTRUCTION New Dwellings and Additions MIAMI COUNTY, KANSAS CODE SERVICES DEPARTMENT 201 South Pearl Street, Suite 201 Paola, Kansas 66071-1777 Phone:
More informationGRAND PRIZE WINNER. ZeroEnergy Design. Phone: Website: Sponsors:
GRAND PRIZE WINNER ZeroEnergy Design Phone: 617.861.4793 Email: sh@zeroenergy.com Website: www.zeroenergy.com Sponsors: Entry P122 The Little Green Rhody Narrative We are pleased to submit a net-zero
More informationTechnical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept.
Technical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept. 1986) Abstract: Details and construction of brick masonry for passive solar
More informationInsulated Siding as Home Insulation
Insulated Siding as Home Insulation Before After Insulated Siding Energy Performance Study Newport Ventures, Inc. for June 2013 Table of Contents Executive Summary... 3 Introduction... 5 Selecting the
More informationRETROFIT INSULATION in WOOD ROOFS
NBI: A525.403 RETROFIT INSULATION in WOOD ROOFS ALASKA BUILDING RESEARCH SERIES HCM-01552 Introduction This publication is one of nine that has been translated from Norwegian. They are taken from a series
More informationESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.
* ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015. A Subsidiary of the International Code Council
More informationTitle 24 HERS Certification Training 2016 Guide to HERS Verification of Existing Conditions
Title 24 HERS Certification Training 2016 Guide to HERS Verification of Existing Conditions Version: June 12, 2017 www.calcerts.com 2 Page Copyright CalCERTS, Inc. 2017 V20170612 Acknowledgements CalCERTS
More informationHow to Meet Code and Manage Moisture in an Environment of Increasing Air Tightness Requirements. Ted Winslow
How to Meet Code and Manage Moisture in an Environment of Increasing Air Tightness Requirements Ted Winslow 10.04.17 Builders are taking a Strategic Approach to Meet evolving building code requirements
More informationA. Source Limitations: Obtain each type of building insulation through one source.
SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationPart IV Energy Conservation
OUBCC / Oklahoma version of the 2015 IRC Chapter 11 - AKA the Oklahoma Residential Energy Code Part IV Energy Conservation CHAPTER 11 ENERGY EFFICIENCY N1101.1 Scope. This chapter regulates the energy
More informationContainer Home Presentation Book 4
Valued Reader, Following the incredible popularity of our digital book series The Most Influential Shipping Container Homes Ever Built we have decided to release a number of expanded titles for 2013 showcasing
More informationQuality Control Inspection of Homes with Thermal Imaging
Quality Control Inspection of Homes with Thermal Imaging Sampling of Thermal Images collected during a study of construction quality of homes built recently in the five most populous parishes of Louisiana
More information7520 Casement Windows
Full casement Single casement Double-bottom casement Double casement FULL DOUBLE CASEMENT - Min 1 9 1 6 Max 3 0 5 0 or 2 6 6 0 CASEMENT W/ PICTURE - Min 4 6 1 6 Max 12 0 6 0 with 30 vent set - Minimum
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00
More informationALASKA ENERGY BUILDING STANDARD EFFICIENCY
ALASKA BUILDING ENERGY EFFICIENCY STANDARD SECOND PRINTING JANUARY 1, 2002 ALASKA BUILDING ENERGY EFFICIENCY STANDARD Second Printing Published by Alaska Housing Finance Corporation Research & Rural Development
More informationFairfax County, Virginia
Fairfax County, Virginia Typical Finished Basement Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Wall Construction... 3 Floor/ceiling
More informationBUILDING YOUR HOME the right way
BUILDING YOUR HOME the right way Mirage Super 16 & 20 MIR1676-348-10 Mirage - Super 16 Series MIR1676-349-10 MIR1676-350-10 Available models and floorplans MIR1676-328-10 MIR1676-330-10 MIR1676-333-10
More informationAir Infiltration & Insulation
Control of Air Flow as Part of Thermal Insulation Manufacturer s Instructions to Achieve Energy Efficiency of Any Building Address the role of insulation in a home Today s Presentation Review common types
More informationRESIDENTIAL ENERGY CHAPTER 4
CHAPTER 4 RESIDENTIAL ENERGY PART I ENERGY CONSERVATION SECTION 401 SCOPE 401.1 General. The provisions of this chapter regulate the exterior envelope, as well as, the design, construction and selection
More informationEC The Effective Detective : Finding Energy Savings at Home
University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Historical Materials from University of Nebraska- Lincoln Extension Extension 1978 EC78-2051 The Effective Detective : Finding
More informationHOUSING ENERGY- EFFICIENCY INSPECTION FIELD MANUAL
HOUSING ENERGY- EFFICIENCY INSPECTION FIELD MANUAL CONTENTS PREFACE.................................. 2 ACKNOWLEDGMENTS.........................2 DISCLAIMER................................ 2 REFERENCES...............................2
More informationFlorida HERO Program Residential Eligible Product List All Products
All Products In addition to the HERO Product Eligibility Specifications listed below, it is the sole responsibility of the HERO Contractor and property owner (Project Stakeholders) to meet or exceed applicable
More informationTHE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS
THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS For the Georgia Association of Home Inspectors Bourke Reeve ABOUT SOUTHFACE 1 EARTHCRAFT Regional Green Building Program HISTORY OF ENERGY CODES MEC 1992,
More informationEncapsulated, Sealed & Closed Crawlspace Installation Manual
YourCrawlSpace, Inc. 1007 Johnni4 Dodds Blvd. Mt. Pleasant, SC 29464 Toll Free: 877-44-CRAWL (27295) Local: (843) 593-1115 Encapsulated, Sealed & Closed Crawlspace Installation Manual Copyright 2017 Your
More informationSix Proven Ways to Build. Walls
Six Proven Ways to Build Energy-Smart Whether you build new homes or remodel, these alternative framing techniques will allow you to reach R-40 or better Walls by Bruce Coldham 2-in. sheathing Fiberglass
More informationThe Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage
The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco
More informationIs Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards
Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards Is Yours? A home buyers guide to the energy efficiency requirements of the 2012 International Energy Conservation
More informationNEW HOMES PROGRAM 2017 PROGRAM GUIDE
NEW HOMES PROGRAM 2017 PROGRAM GUIDE Focus on Energy, Wisconsin utilities statewide program for energy efficiency and renewable energy, helps eligible residents and businesses save energy and money while
More informationImprove Energy Efficiency and Air Sealing in Above-Grade Walls
Improve Energy Efficiency and Air Sealing in Above-Grade Walls United States. Residential Energy Efficiency Ranks Highest Second only to the mortgage, a family s home heating and cooling payments represent
More informationPassivhaus Project Documentation Wrexham Passivhaus
Passivhaus Project Documentation Wrexham Passivhaus Design/Architecture: Simmonds Mills Architects Structural ngineer: Bob Johnson Structural ngineers, Shrewsbury Building Services: Alan Clarke Passivhaus
More information2018 WEATHERIZATION SPECIFICATIONS MANUAL
2018 WEATHERIZATION SPECIFICATIONS MANUAL Prepared by: Lockheed Martin December, 2017 Table of Contents INTRODUCTION... 2 IN 1.0 Program Goals and Eligibility... 2 IN 1.1 Code Compliance... 2 IN 1.2 Post
More informationMID-RISE DESIGN & CONSTRUCTION
TECHNICAL BULLETIN No.38-021616 Rev072116 MID-RISE DESIGN & CONSTRUCTION Logix effective R-values range from R-24 to R-28+ Insulated concrete forms (ICF) are becoming a main stream choice for the construction
More informationExample LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal
Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal The following documentation provides an example submittal for the LEED-NC v2.1 Energy & Atmosphere Credit 1 (EAc1). This sample EAc1 submittal
More informationTechnical Bulletin. No. 21 : Insulating Basements and Crawl Spaces (Revised 7/04) hwinsulation CONTRACTORS ASSOCIATION OF AMERICA
hwinsulation CONTRACTORS ASSOCIATION OF AMERICA Technical Bulletin 1321 Duke Street, Suite 303 Alexandria, VA 22314 (703) 739-0356 FAX (703) 739-0412 No. 21 : Insulating Basements and Crawl Spaces (Revised
More information