Bracing Systems. Available At VIKING SA Tel: (+352) Fax: (+352)

Size: px
Start display at page:

Download "Bracing Systems. Available At VIKING SA Tel: (+352) Fax: (+352)"

Transcription

1 Bracing Systems Available At VIKING SA Tel: (+352) Fax: (+352)

2 Bracing Systems To help ensure the availability and operation of safety systems after an earthquake event, many building and industry codes now include requirements for the design and installation of seismic sway bracing for non-structural components, such as fire sprinkler, mechanical, electrical and plumbing systems. The innovative line of CADDY Bracing Systems was developed to help keep fire sprinkler systems intact after a seismic event and to minimize water damage resulting from leaks or ruptures. CADDY Bracing Systems provide contractors with high-quality, engineered solutions, which include rigid bracing, cable bracing and rod stiffeners. Quick and easy installation Lower total installed cost Meets requirements of NFPA 13 culus Listed FM Approved OSHPD Pre-Approved Rigid Bracing Cable Bracing Branch Line Restraint System 2 Rod Stiffeners

3 Rigid Bracing The CADDY line of innovative rigid bracing products was designed to provide superior performance and meet the highest seismic load requirements. The products have been designed with the end user in mind and provide contractors with labor-saving features to promote quick and easy installation. The system of products supports lateral and longitudinal bracing and offers a wide range of structural and pipe attachments. Patent-pending lateral braces eliminate need for multiple trips up and down ladders Adjustable design can be used with different brace pipe sizes, providing flexibility on the jobsite and reducing contractor inventory Snap-off bolt head helps enable easy installation and inspection of seismic sway braces culus Listed FM Approved OSHPD Pre-Approved (OPA-2629-) to the 20 California Building Code Structural Attachments for Rigid Bracing Sway Braces 3 Replacement Nuts and Bolts for Rigid Bracing

4 Structural Attachments for Rigid Bracing Bar Joist Attachment Adjustable I-Beam Attachment Strut Seismic Hinge Universal Structural Attachment 4 Multi Attachment

5 Bar Joist Attachment Can be installed on bar joists or I-beams Thumb spring retainer allows for ease of positioning Snap-off bolt head helps enable easy installation and inspection of seismic sway braces No assembly required No loose parts Meets NFPA -13 requirements for seismic sway bracing CSBBARJEG 4354 CSBBARJHD Finish Flange Thickness FT A B C Electro-galvanized 6,4 12,7 mm 50,8 mm 76,2 mm 63,5 mm Hot-dip galvanized 6,4 12,7 mm 50,8 mm 76,2 mm 63,5 mm UL Loads Brace Direction to Structure Size Rating Parallel mm Perpendicular mm N FM Loads Horizontal Capacity per Intallation Angle from Vertical Brace Direction Size Parallel 6270 N 9385 N N N Perpendicular 77 N 7605 N 9165 N 230 N 5

6 Adjustable I-Beam Attachment No loose parts No assembly required Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Meets NFPA -13 requirements for seismic sway bracing Flange Thickness FT A Height H Length L Width W CSBIB075085EG ,4 19,1 mm mm 63,5 mm 304,8 mm 69,9 mm CSBIB075145EG ,4 19,1 mm mm 63,5 mm 431,8 mm 69,9 mm CSBIB125180EG ,1 31,8 mm mm 88,9 mm 546,1 mm 79,4 mm UL Loads Brace Direction to Structure Size Rating Parallel mm Perpendicular mm N FM Loads Horizontal Capacity per Installation Angle from Vertical Brace Direction Size Parallel 7,205 N 7,605 N 4,495 N 4,9 N Perpendicular 7,205 N,230 N 12,545 N 13,965 N

7 Multi Attachment Disperses load over two anchors Minimizes the number of installed braces needed for concrete and wood structures Ideal for deck installations Use for both lateral and longitudinal sway brace applications Meets NFPA -13 requirements for seismic sway bracing Article Number Hole Size 1 HS1 Hole Size 2 HS2 A B C D UL Listed Load CSBMA050050EG ,8 mm 63,5 mm 63,5 mm 228,6 mm N CSBMA050075EG mm 304,8 mm 63,5 mm 63,5 mm 228,6 mm N Mount to structure using holes indicated in HS1. 7

8 Strut Seismic Hinge Complete hinge assembly Ideal for attaching sway bracing to MEP system supports Attaches to strut trapezes and to structure Hole Size 1 HS1 Hole Size 2 HS2 Length L Width W Thickness T CSBSH00375EG mm 179,8 mm 41,3 mm 6,4 mm CSBSH00500EG ,8 mm 41,3 mm 6,4 mm CSBSH00625EG mm 179,8 mm 41,3 mm 6,4 mm CSBSH00750EG mm 179,8 mm 41,3 mm 6,4 mm 8

9 Universal Structural Attachment Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Use for both lateral and longitudinal sway brace applications Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Center bolt does not require tightening Meets NFPA -13 requirements for seismic sway bracing Hole Size HS A B C CSBUNIV050EG ,4 mm 1,6 mm 41,4 mm CSBUNIV075EG mm 133,4 mm 1,6 mm 41,4 mm UL Loads Brace Type Size Rating Pipe 25 mm mm 13,3 N 6mm Thick Angle 25 mm mm 8,960 N FM Loads Brace Type Size Pipe Horizontal Capacity per Installation Angle from Vertical ,205 N,230 N 12,545 N 13,965 N 9

10 Shear Bolt Description CSBBARJSB50EG 2502 Shear Bolt for Bar Joist Attachment CSBIBSB50EG 2501 Shear Bolt for I-Beam Attachment CSBUNIVSB62EG 2503 Shear Bolt for Universal Sway Brace and Universal Structural Attachment Shear Nut Description CSBIBSN37EG 2500 Shear Nut for Adjustable I-Beam Attachment CSBQIKCLSN37EG 2505 Shear Nut for Quick Grip Jr. Lateral Sway Brace, mm NB/DN

11 Sway Braces Easy Universal Sway Brace Standard Universal Sway Brace Quick Grip Jr. Lateral Sway Brace Quick Grip Lateral Sway Brace Easy Universal Sway Brace Use for both lateral and longitudinal sway brace applications Unique slotted holes provide for easy slip-on installation eliminating loose hardware Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Meets NFPA -13 requirements for seismic sway bracing Pipe Size NB/DN A B Listings Approvals CSBEZU00EG " 25 mm 174,6 mm 25,4 mm UL, FM CSBEZU0125EG /4" 32 mm 187,4 mm 25,4 mm UL, FM CSBEZU0150EG /2" mm 196,9 mm 25,4 mm UL, FM CSBEZU0200EG " 50 mm 206,4 mm 30,2 mm UL, FM CSBEZU0250EG /2" 65 mm 225,4 mm 30,2 mm CSBEZU0300EG " 80 mm 238,1 mm 30,2 mm CSBEZU00EG " 0 mm 269,9 mm 38,1 mm CSBEZU0500EG " 125 mm 308 mm 38,1 mm CSBEZU0600EG " 150 mm 346,1 mm 50,8 mm 11

12 UL Loads (Listed for Restraints) Dyna-Flow Sch Sch CSBEZU00EG CSBEZU0125EG CSBEZU0150EG UL Loads (Listed for Sway Braces) Lateral Longitudinal Dyna-Flow EZ FLOW Sch Sch CSBEZU0200EG CSBEZU0250EG CSBEZU0300EG CSBEZU00EG CSBEZU0500EG CSBEZU0600EG Dyna-Flow Mega-Flow Sch Sch 5620 N 5620 N 5620 N 5620 N 5620 N 5620 N 5620 N 5620 N 5620 N 71 N 71 N 71 N 71 N 71 N 71 N FM Loads (Lightwall, Sch and Sch s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal CSBEZU00EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0125EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0150EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0200EG 6805 N 96 N N N 2315 N 3070 N 3690 N 4136 N CSBEZU0250EG 6805 N 96 N N N 2315 N 3070 N 3690 N 4136 N CSBEZU0300EG 6805 N 96 N N N 2315 N 3070 N 3690 N 4136 N CSBEZU00EG 6985 N 9875 N 120 N N 2800 N 05 N 4895 N 5470 N CSBEZU0500EG 6985 N 9875 N 120 N N 2800 N 05 N 4895 N 5470 N CSBEZU0600EG 8805 N N N N 3245 N 4450 N 5470 N 6095 N 12

13 Standard Universal Sway Brace Use for both lateral and longitudinal sway brace applications Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Slotted design grabs service pipe for added gripping strength Meets NFPA -13 requirements for seismic sway bracing Pipe Size NB/DN A B Listings Approvals CSBSTU00EG " 25 mm 174,6 mm 25 mm UL, FM CSBSTU0125EG /4" 32 mm 187,4 mm 25,4 mm UL, FM CSBSTU0150EG /2" mm 196,9 mm 25,4 mm UL, FM CSBSTU0200EG " 50 mm 206,4 mm 30,2 mm UL, FM CSBSTU0250EG /2" 65 mm 225,4 mm 30,2 mm CSBSTU0300EG " 80 mm 238,1 mm 30,2 mm CSBSTU00EG " 0 mm 269,9 mm 38,1 mm CSBSTU0500EG " 125 mm 308 mm 38,1 mm CSBSTU0600EG " 150 mm 346,1 mm 50,8 mm CSBSTU0800EG " 200 mm 0,1 mm 50,8 mm CSBSTU00EG 4395 " 250 mm 457,2 mm 50,8 mm CSBSTU00HD 1" 25 mm 174,6 mm 25 mm UL, FM CSBSTU0125HD 1 1/4" 32 mm 187,4 mm 25,4 mm UL, FM CSBSTU0150HD 1 1/2" mm 196,9 mm 25,4 mm UL, FM CSBSTU0200HD 2" 50 mm 206,4 mm 30,2 mm UL, FM CSBSTU0300HD 3" 80 mm 238,1 mm 30,2 mm CSBSTU00HD 4" 0 mm 269,9 mm 38,1 mm CSBSTU0500HD 5" 125 mm 308 mm 38,1 mm CSBSTU0600HD 6" 150 mm 346,1 mm 50,8 mm CSBSTU0800HD 8" 200 mm 0,1 mm 50,8 mm CSBSTU00HD " 250 mm 457,2 mm 50,8 mm Finish: Hot-dip galvanized UL Loads (Listed for Restraints) Dyna-Flow Sch Sch CSBSTU00xx CSBSTU0125xx CSBSTU0150xx 13

14 UL Loads (Listed for Sway Braces) Lateral Longitudinal Dyna-Flow EZ FLOW Sch Sch CSBSTU0200xx CSBSTU0250xx CSBSTU0300xx CSBSTU00xx CSBSTU0500xx CSBSTU0600xx CSBSTU0800xx CSBSTU00xx Dyna-Flow EZ FLOW Sch Sch FM Loads (Lightwall, Sch and Sch s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal CSBSTU00xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0125xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0150xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0200xx 6805 N 96 N N N 3870 N 3070 N 3690 N 4136 N CSBSTU0250xx 6805 N 96 N N N 3870 N 3070 N 3690 N 4136 N CSBSTU0300xx 6805 N 96 N N N 3870 N 3070 N 3690 N 4136 N CSBSTU00xx 6985 N 9875 N 120 N N 6895 N 6185 N 7475 N 8320 N CSBSTU0500xx 6985 N 9875 N 120 N N 6895 N 6185 N 7475 N 8320 N CSBSTU0600xx 8805 N N N N 65 N 5205 N 6270 N 6985 N FM Loads (4.8 mm wall and Sch s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal CSBSTU0800xx 9075 N N N N 53 N 7560 N 9295 N 365 N CSBSTU00xx 9075 N N N N 53 N 7560 N 9295 N 365 N 14

15 Quick Grip Jr. Lateral Sway Brace Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4" (25 mm and 32 mm) brace pipes to reduce inventory Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Meets NFPA -13 requirements for seismic sway bracing Pipe Size NB/DN Height H Width W CSBQIKCL00EG " 25 mm 130,2 mm 65,3 mm CSBQIKCL0125EG /4" 32 mm 136,5 mm 74,4 mm CSBQIKCL0150EG /2" mm 142,9 mm 80,2 mm CSBQIKCL0200EG " 50 mm 161,9 mm 92,3 mm UL Loads (Listed for Restraints) CSBQIKCL00EG CSBQIKCL0125EG CSBQIKCL0150EG CSBQIKCL0200EG Lateral Schedule 25 mm Brace Pipe 32 mm Brace Pipe Dyna-Flow Dyna-Flow 20 N 20 N 20 N Dyna-Flow 3330 N 3330 N 3330 N Dyna-Flow 3330 N 20 N 3330 N 20 N 3330 N 20 N 15

16 FM Loads Lateral Horizontal per Installation Angle from Vertical Schedule Lightwall CSBQIKCL00EG CSBQIKCL0125EG CSBQIKCL0150EG CSBQIKCL0200EG N 1830 N 2200 N 2445 N 665 N 935 N 1245 N 10 N 2115 N 2960 N 3670 N 4115 N Lightwall 1290 N 1830 N 2200 N 2445 N 665 N 935 N 1245 N 10 N 2115 N 2960 N 3670 N 4115 N Lightwall 1290 N 1830 N 2200 N 2445 N 665 N 935 N 1245 N 10 N 2115 N 2960 N 3670 N 4115 N Lightwall 1735 N 2445 N 2980 N 3335 N 1555 N 2225 N 2760 N 3070 N 2180 N 3070 N 3780 N 4225 N Quick Grip Lateral Sway Brace The Quick Grip Lateral Brace, part of the CADDY line of fire sprinkler bracing systems from ERICO, is designed to help simplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design for quick attachment of brace pipe to service pipe saving time and money. Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4" (25 mm and 32 mm) brace pipes to reduce inventory Yellow tips provide a visual indicator that the bolts have been properly torqued Easy installation with an impact wrench from the bottom side of the clamp Meets NFPA -13 requirements for seismic sway bracing Pipe Size NB/DN Height H Width W 65 mm 138,1 148,6 mm 172 mm CSBQG0250EG /2" CSBQG0300EG " 80 mm ,5 mm 190 mm CSBQG00EG " 0 mm 180,4 190,9 mm 222 mm CSBQG0500EG " 125 mm 205,8 217,9 mm 260 mm CSBQG0600EG " 150 mm 235,5 244,9 mm 298 mm CSBQG0800EG " 200 mm 289,2 300 mm 351,8 mm 16

17 UL Loads Lateral Schedule CSBQG0250EG CSBQG0300EG CSBQG00EG CSBQG0500EG CSBQG0600EG CSBQG0800EG 25 mm Brace Pipe 32 mm Brace Pipe Dyna-Flow Dyna-Flow Dyna-Flow Mega-Flow FM Loads Lateral CSBQG0250EG CSBQG0300EG CSBQG00EG CSBQG0500EG CSBQG0600EG CSBQG0800EG Horizontal Capacity per Installation Angle from Vertical Schedule Lightwall 6270 N 8895 N 900 N N 6270 N 8895 N 900 N N 6270 N 8895 N 900 N N Lightwall 5295 N 7475 N 9163 N 230 N 5295 N 7475 N 9163 N 230 N 5295 N 7475 N 9163 N 230 N Lightwall 5295 N 7475 N 9163 N 230 N 5295 N 7475 N 9163 N 230 N 5295 N 7475 N 9163 N 230 N Lightwall 3870 N 5470 N 6715 N 7515 N 3870 N 5470 N 6715 N 7515 N 4315 N 6095 N 7475 N 8320 N Lightwall 3870 N 5470 N 6715 N 7515 N 3870 N 5470 N 6715 N 7515 N 4315 N 6095 N 7475 N 8320 N 4.8 mm (Wall Thickness) 3515 N 49 N 6050 N 6760 N 3515 N 49 N 6050 N 6760 N 17

18 Cable Bracing CADDY cable bracing is an ideal alternative to rigid bracing for fire sprinkler systems when brace lengths greater than 19-8 (6 m) are required or when confined/crowded spaces make rigid systems difficult to install. The system includes pre-stretched steel cable, attachment fittings, crimping sleeves and related tools. The system can also be used to brace electrical, mechanical and plumbing systems. Color-coated cable conforms to NFPA 13 requirements and makes it highly visible and easier to identify cable sizes UL Listed OSHPD Pre-Approved (OPA-0619) Cable Spool Crimping Sleeve Loop Attachment Kit No Pry Clip Stake Eye Kit Cable Cutter 18

19 Swaging Tools Universal Restraint Clip Universal Restraint Clip, Retrofit Cable Spool Cut to length as needed Pre-stretched restraint cable Finish: Pre-galvanized, Painted Brace Size Diameter Cable Length UL Listed Load Color CSB12CBL 2190 #12 2,4 mm 76,2 m N Red CSB18CBL 2191 #18 3,2 mm 76,2 m N White CSB36CBL 2192 #36 4,8 mm 76,2 m N Blue CSB48CBL 2193 #48 6 mm 76,2 m N Yellow Cable is powder coated. 19

20 Crimping Sleeve Creates secure loop ends Crimp with swaging tools Material: Copper Brace Size CSB12SLVB 2194 #12 CSB18SLVB 2195 #18 CSB36SLVB 2196 #36 CSB48SLVB 2197 #48 Two side-by-side crimps required on #12 and #18 cable. Three side-by-side crimps required on #36 and #48 cable. Check crimp with gauge (not included). Loop Attachment Kit Two-way bracing kit with crimp sleeves Wraps around structural steel members Brace Size Brace Length Cable Length UL Listed Load Color CSB12B00L #12 2,1 m 3,3 m N Red CSB12B00L 2232 #12 3,0 m 4,2 m N Red CSB18B00L #18 2,1 m 3,3 m N White CSB18B00L 2233 #18 3,0 m 4,2 m N White Stake eyes not included. 20

21 No Pry Clip Eliminates prying effect on fasteners and anchors CSBNPC Brace Size Hole Size UL Listed Load #12, #18, # N Stake Eye Kit Attaches to steel, wood or concrete structures Two-way bracing kit with crimp sleeves and stake eyes Swaged-on stake eye, pre-bent to 45 degrees Article Number Brace Size Hole Size Brace Length Cable Length UL Listed Load Color CSB12BD38L #12 11 mm 2,1 m 3,3 m N Red CSB12BD38L 2221 #12 11 mm 3,0 m 4,2 m N Red CSB12BD50L #12 2,1 m 3,3 m N Red CSB12BD50L 2227 #12 3,0 m 4,2 m N Red CSB18BD38L #18 11 mm 2,1 m 3,3 m N White CSB18BD38L 2222 #18 11 mm 3,0 m 4,2 m N White CSB18BD50L #18 2,1 m 3,3 m N White CSB18BD50L 2228 #18 3,0 m 4,2 m N White CSB36BD38L #36 11 mm 2,1 m 3,3 m N Blue 21

22 Article Number Brace Size Hole Size Brace Length Cable Length UL Listed Load Color CSB36BD38L 2223 #36 11 mm 3,0 m 4,2 m N Blue CSB36BD50L #36 2,1 m 3,3 m N Blue CSB36BD50L 2229 #36 3,0 m 4,2 m N Blue Kits contain copper sleeves. 22

23 Swaging Tools Manual Swaging Tool Multi-Size Manual Swaging Tool Manual Swaging Tool Brace Size Listings CSB12SBHS 4461 #12 - CSB #48 UL 23

24 Multi-Size Manual Swaging Tool CSB3346SB Brace Size 2209 #12, #18, #36 Universal Restraint Clip Attaches cable brace to structure Brace Size Hole Size HS UL Listed Load CSBURC #12, #18, #36 11 mm N CSBURC #12, #18, # N CSBURC #12, #18, #36 17 mm N CSBURC # N CSBURC #48 17 mm N CSBURC #48 21 mm N Mount to the structure using the center hole. Loop cable through the holes in the bent tabs and crimp in place. For #48 cable, use two clips stacked together. 24

25 Universal Restraint Clip, Retrofit Slotted design ideal for attaching to existing threaded rod on trapezes Brace Size Rod Size RS CSBURCR #12, #18 M CSBURCR #12, #18 M12 CSBURCR #12, #18 M16 One fastener required for #12 cable. Two stacked fasteners required for #18 cable. 25

26 Branch Line Restraint System Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1 (25 mm) through 2 (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlins, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16 (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 80% compared to other methods. Unlike most solutions that only accept 3/8 (M) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3/8 or 1/2 (M or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2 (M12) threaded rod. The system meets the requirements of NFPA 13, making it ideal for new construction applications. The total system is culus Listed and FM Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-). Complete restraint system is quick and easy to install Offers up to 80% time savings per branch line restraint Eliminates need to cut threaded rod to exact dimensions Works with 3/8 and 1/2 (M and M12) rod Capable of restraint distances up to (960 mm) from pipe to structure with 1/2 (M12) threaded rod Meets requirements of NFPA 13 section Branch Line Restraint Pipe Attachment Branch Line Restraint Structure Attachment to Steel Branch Line Restraint Structure Attachment to Wood/Concrete 26 Branch Line Restraint Structure Attachment to Threaded Hole

27 Branch Line Restraint Pipe Attachment Accepts 3/8 or 1/2 (M or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can be installed with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection Article Number Pipe Size NB/DN Outer Diameter OD Rod Size RS Height H Length L Width W 169,4 mm 41,4 mm 22,2 mm CSBBRP00EG " 25 mm 33,4 mm M, M12 CSBBRP0125EG /4" 32 mm 42,2 mm M, M mm 50 mm 22,2 mm CSBBRP0150EG /2" mm 48,3 mm M, M12 208,4 mm 56,1 mm 22,2 mm CSBBRP0200EG " 50 mm 60,3 mm M, M12 2 mm 68,3 mm 22,2 mm 27

28 Branch Line Restraint Structure Attachment to Steel Swivel connector accepts 3/8 or 1/2 (M or M12) threaded rod Attaches to steel members with self-drilling/tapping screw CSBBRS1MEG Article Number 2239 Rod Size RS Flange Thickness FT Height H Length L Width W Screw Diameter Sc Screw Length L M, M12 2,7 12,7 mm 28,2 mm,4 mm 26,9 mm #12 32 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. Branch Line Restraint Structure Attachment to Wood/Concrete Swivel connector accepts 3/8 or 1/2 (M or M12) threaded rod Attaches to wood or concrete structures CSBBRS2MEG Article Number 22 Rod Size RS Height H Length L Width W Screw Diameter Sc Screw Length L Drill Bit Size M, M12 28,2 mm,4 mm 26,9 mm 6,4 mm 45 mm 4,8 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. 28

29 Branch Line Restraint Structure Attachment to Threaded Hole Swivel connector accepts 3/8 or 1/2 (M or M12) threaded rod Attaches to concrete anchors or structural attachments with female threads CSBBRS3MEG Article Number 2241 Rod Size RS Height H Length L Width W Screw Diameter Sc Screw Length L M, M12 28,2 mm,4 mm 26,9 mm M 19 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. 29

30 Rod Stiffeners Pipe Rod Stiffener Pipe Rod Stiffener For use with Schedule or Schedule pipe Secures pipe to threaded rod for stiffening CSBRS Brace Pipe Size Brace NB/DN Rod Size 1" 25 mm M, M12, M16 30

31 culus is a registered certification mark of UL LLC. Dyna-Flow is a registered trademark of Allied Tube & Conduit Corporation. EZ FLOW is a trademark of Northwest Pipe Company. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL is a registered certification mark of UL LLC. WARNING ERICO products shall be installed and used only as indicated in ERICO s product instruction sheets and training materials. Instruction sheets are available at and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyer's receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer. THE FOREGOING STATES BUYER S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICO's employees. Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER. Copyright 2013 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. 31

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations TOLCO Fire Protection Support Systems Pipe Hangers Supports Seismic Bracing UL Listed FM Approved for Fire Sprinkler Installations Revision 12/06/2007 Catalog Forward This catalog has been created with

More information

Fig. 1 - Standard Clevis Hanger

Fig. 1 - Standard Clevis Hanger Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension

More information

Large cable sizes stronger than pipe/strut

Large cable sizes stronger than pipe/strut Legrand Seismic Wire Rope/Cable Bracing is the recommended seismic bracing for Legrand wire mesh and ladder tray systems. It is UL Listed, complies with all building codes and standards, and offers significant

More information

Fig Beam Clamp Retaining Strap (B-Line B3367)

Fig Beam Clamp Retaining Strap (B-Line B3367) Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

Seismic Installation Manual

Seismic Installation Manual Seismic Installation Manual California Office of Statewide Health Planning & Development OPA-2123-10 This manual provides the design strength capacities and installation guidelines for the Bracing System

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

KINETICS Pipe & Duct Seismic Application Manual

KINETICS Pipe & Duct Seismic Application Manual KINETICS ipe & Duct Seismic Application Manual FIRE ROTECTION IING SYSTEMS S13.1 Introduction: Historically the ICC (2000, 2003, 2006, and 2009 IBC) and the NFA (NFA 5000) have been competing code writing

More information

SECTION SEISMIC CONTROL OSHPD

SECTION SEISMIC CONTROL OSHPD SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components

More information

Suspension System Data Center Ceiling Solutions

Suspension System Data Center Ceiling Solutions Hardware That Needs to be Purchased Separately Screws are fine listed as shown: Min 1-1/4" or longer #8 Truss head self-tapping screws for attaching structural wall angle, lateral support bar 16" or 4"

More information

KINETICS Pipe & Duct Seismic Application Manual

KINETICS Pipe & Duct Seismic Application Manual QUICK START READ ME FIRST I1.1 Seismic Restraint Categories and Types: Seismic restraints for pipe and duct are generally separated into to two categories. 1. Transverse Seismic Restraints: These act to

More information

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Model # 238HS-P8. 4/27/2011 Page 1 of 11 Model # 238HS-P8 4/27/2011 Page 1 of 11 4/27/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Series 5500 Bellows Pump Connectors Catalog 474E

Series 5500 Bellows Pump Connectors Catalog 474E Series 5500 Bellows Pump Connectors Catalog 474E Series 5500 Bellows Pump Connectors Sizes 1-1 /2 through 24 Design Conditions: full vacuum to 150 and 300 psig at 500 F Compact design with maximum flexibility

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available. Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon

More information

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual FORM HEADWALL (floating) Installation Manual FORM HEADWALL (floating) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated

More information

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Model # 800SM-PS3. 8/3/2016 Page 1 of 8 Model # 800SM-PS3 8/3/2016 Page 1 of 8 /3/2016 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass

Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass Dexco Cantilever Rack Systems offer the strength, durability and layout to store

More information

-165 C / -265 F CRYOGENIC REBAR SPLICING SYSTEMS

-165 C / -265 F CRYOGENIC REBAR SPLICING SYSTEMS -165 C / -265 F CRYOGENIC REAR SPLICING SYSTEMS Cryogenic Rebar Splicing Systems Cryogenic Rebar Splicing systems are an extension to the LENTON line of concrete reinforcement products available from Pentair.

More information

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA TABLE OF CONTENTS TABLE OF CONTENTS SAFETY REGULATIONS MATERIALS REQUIRED ASSEMBLY ENGINEERING DRAWINGS TERMS AND CONDITIONS

More information

American Metal Specialties, Inc.

American Metal Specialties, Inc. American Metal Specialties, Inc. www.cablerailings.com (253) 272-9344 (253) 627-3843 Fax PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 05 73 00 STAINLESS STEEL ORNAMENTAL HANDRAILS AND RAILINGS For best

More information

Model # 158-P4. 12/12/2013 Page 1 of 11

Model # 158-P4. 12/12/2013 Page 1 of 11 Model # 158-P4 12/12/2013 Page 1 of 11 2/12/2013 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

CADWELD Rebar Metal Filled Mechanical Splices

CADWELD Rebar Metal Filled Mechanical Splices CADWELD Rebar Metal Filled Mechanical Splices The Company ERICO is a leading designer, manufacturer and marketer of precisionengineered specialty metal products serving global niche product markets in

More information

Model # 358H-PR. 4/8/2011 Page 1 of 12

Model # 358H-PR. 4/8/2011 Page 1 of 12 Model # 358H-PR 4/8/2011 Page 1 of 12 4/8/2011 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Model # 358-R48. 7/7/2011 Page 1 of 11

Model # 358-R48. 7/7/2011 Page 1 of 11 Model # 358-R48 7/7/2011 Page 1 of 11 7/7/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

Dura Rack Family Of Products. 237,000 sq. ft. manufacturing facility

Dura Rack Family Of Products. 237,000 sq. ft. manufacturing facility Dura Rack Family Of Products 237,000 sq. ft. manufacturing facility Dixie Industrial Shelving Pages 2 7 Dixie Widespan Shelving Pages 8 10 Dura Rack Pallet Rack Pages 11 16 Dura Rack Structural Pallet

More information

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity HANDSET WALL FORM Quick Assembly - can be built using only a hammer Reduced weight increases productivity Unsurpassed flexibility in design and availability of panels for a wide variety of applications

More information

Protective Capony RTC-16

Protective Capony RTC-16 Protective Capony RTC-16 ASSEMBLY AND OPERATION MANUAL Protective Canopy RTC-16 Assembly and Operation Manual CONTENT: 1 APPLICATION...3 2 OPERATION CONDITIONS...3 3 TECHNICAL SPECIFICATIONS...3 4 DELIVERY

More information

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural cantilever rack design. In addition, it is

More information

MECHANICAL AND PLUMBING SUPPORTS. To order online vist us at.

MECHANICAL AND PLUMBING SUPPORTS. To order online vist us at. MECHANICAL AND PLUMBING SUPPORTS To order online vist us at www.ceasattachments.com Corporate Headquarters Construction Engineered Attachment Solutions 14848 Northam St., La Mirada, CA 90635 Tel: 877-GOO-CEAS

More information

RHE3 Dock Leveler Installation Manual

RHE3 Dock Leveler Installation Manual RHE3 Dock Leveler Installation Manual MADE IN U.S.A. This Manual Covers Dock Levelers Built After Serial Numbers: 07FE160001M and up PRINTED IN U.S.A. RITE-HITE PRINT SHOP PUBLICATION NO. 1222 MAY 2007

More information

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms REV. 9/08 Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms SKYTRON MOUNTING STRUCTURES for Ceiling Mounted Equipment Foreword Skytron s objective is to provide a program and guideline to assist

More information

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders Welcome to the O Keeffe s Guide Specification System prepared as an aid to specify in preparing written construction documents. For specification assistance with specific product applications, please contact

More information

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017 Installation Guide Document No. 1788-01 Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL:

More information

PEN SEAL. Pipe Penetration Seals

PEN SEAL. Pipe Penetration Seals PEN SEAL Pipe Penetration Seals PROCO s Pipe Penetration Seals have been designed to assist in achieving an efficient, low-cost mechanical seal between any Electrical Conduit, Concrete, Cast Iron, Steel,

More information

Smarter. Safer. Leaner.

Smarter. Safer. Leaner. Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter

More information

Drag Chain Conveyor Installation and Operation Manual

Drag Chain Conveyor Installation and Operation Manual Drag Chain Conveyor Installation and Operation Manual Material Handling Equipment Sales, Incorporated 310 S. Section Line Rd Delaware, OH 43015 Phone: (989) 430-4005 Fax: (740) 363-9004 WARRANTY MATERIAL

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

Model # 338S-OP. 9/30/2011 Page 1 of 13

Model # 338S-OP. 9/30/2011 Page 1 of 13 Model # 338S-OP 9/30/2011 Page 1 of 13 9/30/2011 Page 2 of 13 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

RIGID LIFELINES PRODUCT SPECIFICATIONS 1

RIGID LIFELINES PRODUCT SPECIFICATIONS 1 RIGID LIFELINES PRODUCT SPECIFICATIONS 1 This guide can be used to prepare a bid specification for the incorporation of a Ceiling-Mounted Monorail Anchor Track System into a competitive bid project or

More information

Model # BARK-358-RDP

Model # BARK-358-RDP Model # BARK-358-RDP 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic/Canine coated elements. guarantees all

More information

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series

More information

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety Instructions for Part # SC500-AF General Guidelines It is the user s responsibility to read and follow all instructions. Keep these instructions with the product at all times and review before each use.

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT SECTION 220529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.

More information

Product Specifications MRI Trench Duct

Product Specifications MRI Trench Duct NOVA Energy & Automation Product Specifications MRI Trench Duct Model AT Aluminum Non Ferrous 03 January 2012 Product 1. Non Ferrous Large Capacity Trench (Floor) Duct Non Ferrous (Aluminum) Large capacity

More information

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038) ICBO Evaluation Service, Inc. 5360 WORKMAN MILL ROAD WHITTIER, CALIFORNIA 90601-2299 A subsidiary corporation of the International Conference of Building Officials EVALUATION REPORT Copyright 2001 ICBO

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems.

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems. SECTION 26 05 29 HANGERS AND SUPPORTS FOR PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Hangers and supports for electrical equipment and systems. 1.2 DEFINITIONS A. EMT: Electrical

More information

SECTION I -- IRONWORK

SECTION I -- IRONWORK SECTION I -- IRONWORK CONTENTS PAGE 1. GENERAL... I-2 1.1. Introduction... I-2 2. REQUIREMENTS... I-2 2.1. General... I-2 2.2. Auxiliary Framing... I-2 2.3. High Seismic Risk Zone Requirements... I-3 2.4.

More information

REPORT HOLDER: LOOS & CO., INC. 901 INDUSTRIAL BOULEVARD NAPLES, FLORIDA EVALUATION SUBJECT:

REPORT HOLDER: LOOS & CO., INC. 901 INDUSTRIAL BOULEVARD NAPLES, FLORIDA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Listing Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESL 1004 Reissued 03/2017 This listing is subject to renewal 03/2018. DIVISION: 13 00 00

More information

Fire protection solutions

Fire protection solutions Fire Protection FPS-13R Fire protection solutions Eaton and Cooper united. Energizing a world that demands more. Discover today s Eaton. Powering business worldwide s a global diversifi ed power management

More information

Fire Barrier Duct Wrap 615+

Fire Barrier Duct Wrap 615+ Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire

More information

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe MEGALUG Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe Features and Applications: Sizes 3 inch through 54 inch Constructed of ASTM A536 Ductile Iron Torque Limiting Twist-Off Nuts Nominal

More information

WHAT IS CANTILEVER RACK?

WHAT IS CANTILEVER RACK? PRODUCT INFORMATION WHAT IS CANTILEVER RACK? 2946 Larimer St. Denver, CO 80205 303-295-1100 / 800-373-7693 FAX 303-295-2464 Email info@snyderequipment.com www.snyderequipment.com MODERN EQUIPMENT COMPANY,

More information

CHAIN LINK FENCES AND GATES

CHAIN LINK FENCES AND GATES SECTION 02831 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.01 SUMMARY A. Alternate Material for Fence Post and Framing Material: Where schedule 40 galvanized steel is specified, the following will be accepted:

More information

7 PIECE TUBE FLARING KIT

7 PIECE TUBE FLARING KIT 7 PIECE TUBE FLARING KIT Model 5969 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from

More information

Technical Services Information Bureau

Technical Services Information Bureau Technical Services Information Bureau INSTALLING ACOUSTICAL LAY-IN TYPE CEILINGS IN SEISMIC REGIONS AUGUST 2009 UPDATED MAY 2017 TECHNICAL BULLETIN This document covers the installation practices recognized

More information

Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP

Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP Insulated Fire-Rated Access Door INSTALLATION, OPERATION & MAINTENANCE MANUAL Table of Contents Insulated Fire-Rated Access Door Table of Contents General Description...3 Installation...4-7 Operation...8

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-13 48 00 (August 2008) --------------------------- Preparing Activity: USACE Superseding UFGS-13 48 00 (October 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

GALVA-STOP. Pallet Rack Backing Safety System

GALVA-STOP. Pallet Rack Backing Safety System GALVA-STOP Pallet Rack Backing Safety System INDEX ABOUT GALVA-STOP PALLET RACK BACKING SAFETY SYSTEM...4 VERTICAL PANELS FOR NEW INSTALLATIONS OVERVIEW AND ILLUSTRATIONS...5 VERTICAL PANELS FOR TOP BAY

More information

The Insert that Changed the the Anchoring Industry!

The Insert that Changed the the Anchoring Industry! The Insert that Changed the the Anchoring Industry! Cutaway View Showing Multiple Internal Threads Reduce labor costs Ideal for gravity & seismic anchorage Multiple internal threads reduces inventory Allows

More information

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing MERCHANTS METALS SECTION 32 31 13 COLORBOND CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements,

More information

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS Model # 349S-P6 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all

More information

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories. SECTION 02830 CHAIN LINK FENCES AND GATES (GALVANIZED) 1.0 GENERAL 1.1 Section Includes A. Fence framework, fabric, gates, and accessories. B. Excavation for post bases; concrete footing for posts. C.

More information

hors Anc Eaton's B-Line series fasteners 183

hors Anc Eaton's B-Line series fasteners 183 183 Glossary Prefix - Description Screw Dia. Length Suffix ACB - Concrete Anchor Bolt 4 - #4 75-3 /4" AN - Acorn Nut ACPD - Bang-IT 6 - #6 81-13 /16" CH - Combo Head ACPW - Wood-Knocker 8 - #8 87-7 /8"

More information

PERFORM WITH PRECISION BOX CULVERT TRAVELER CONCRETE CONSTRUCTION PRODUCTS APPLICATION GUIDE

PERFORM WITH PRECISION BOX CULVERT TRAVELER CONCRETE CONSTRUCTION PRODUCTS APPLICATION GUIDE PERFORM WITH PRECISION BOX CULVERT TRAVELER CONCRETE CONSTRUCTION PRODUCTS APPLICATION GUIDE A WORD ABOUT SAFETY High productivity depends on safety; even a minor accident causes job delays and inefficiency,

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

SECTION 1043 FENCE MATERIAL

SECTION 1043 FENCE MATERIAL SECTION 1043 FENCE MATERIAL 1043.1 Scope. This specification covers the material required in the construction of chainlink fence and woven wire fence. 1043.2 Basis of Acceptance. The basis of acceptance

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS Model # BARK-420 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic/Canine coated elements. guarantees all items

More information

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth

More information

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution DURA-BLOK rooftop supports BRTS-17 B-LINE SERIES DURA-BLOK A complete rooftop support solution DURA-BLOK rooftop solutions support DURA-BLOK supports are made of 100% recycled rubber and are designed to

More information

ROLLING RACK. Simple Security

ROLLING RACK. Simple Security Simple Security The graceful design and high security of the Rolling Rack has made this type of bike rack a standard for many schools and communities. The Rolling Rack can be used as a single-sided or

More information

B R OA DWAY RAC K. High Security

B R OA DWAY RAC K. High Security B R OA DWAY RAC K High Security The Broadway Rack is a great fit on Broadway or in areas where maximum security is a top priority. Made of thick, two-inch square steel, the Broadway Rack renders pipe-cutters

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF

More information

DRYWALL DOLLY 900 LB. CAPACITY

DRYWALL DOLLY 900 LB. CAPACITY DRYWALL DOLLY 900 LB. CAPACITY 94883 ASSEMBLY & OPERATING INSTRUCTIONS Due to continuing improvement, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo,

More information

TERWA REBAR CONNECTION COUPLERS

TERWA REBAR CONNECTION COUPLERS TERWA REBAR CONNECTION COUPLERS CARES Technical Approval 5058 TA1B Introduction The Terwa Parallel Threaded Coupler is a full bar strength system (the coupling is stronger than the associated rebar, sometimes

More information

Canopies & Exposed Structure Areas Commercial Ceilings and Walls Solutions Guide

Canopies & Exposed Structure Areas Commercial Ceilings and Walls Solutions Guide CEILING & WALL SYSTEMS Canopies & Exposed Structure Areas Commercial Ceilings and Walls Solutions Guide Canopies & Exposed Structures SOUNDSCAPES Acoustical Canopies Product Description SoundScapes are

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Installation Instructions

Installation Instructions Installation Instructions Dynarail Safety Ladder System Corrosion Resistant Nonconductive Fire Retardant High Strength-To-Weight Ratio Long, Low Maintenance Life Meets OSHA, BOCA & Other Building Code

More information

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS Kennedy Valve A Division of McWane, Inc. AWWA PRODUCTS 1021 East Water Street Elmira, NY 14902 Phone: (607)734-2211 Fax: (607)734-3288 Fax: (800)952-4771 E-Mail: sales@kennedyvalve.com www.kennedyvalve.com

More information

ERICO SYSTEM ESE Lightning Protection Products

ERICO SYSTEM ESE Lightning Protection Products ERICO SYSTEM 1000 ESE Lightning Protection Products Active Protection ERICO is a trusted world leader for providing high-quality grounding solutions, lightning protection and surge protection technologies.

More information

80/90/100/120/mm POST Standard Medium Heavy Extra Heavy

80/90/100/120/mm POST Standard Medium Heavy Extra Heavy Upright Profiles 75mm upright pitch Cold Forming Process on a high speed rolling mill Omega section, Front-Centre-Ribbed Powder coated finish Profile width: 80x70, 90x70, 100x70, 120x70mm Standard JIS

More information

Model # 922-S4. 12/18/2013 Page 1 of 8

Model # 922-S4. 12/18/2013 Page 1 of 8 Model # 922-S4 12/18/2013 Page 1 of 8 2/18/2013 Page 2 of 8 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic

More information

GroundTrac. Installation Manual

GroundTrac. Installation Manual APPLICATION: The GroundTrac system is designed with a minimum amount of installed footings at greatly reduced labor. The system integrates with ordinary 1-1/2 schedule #40 galvanized water pipe. This ground

More information

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS SHCM-27180 SHOWER COLUMN INSTALLATION INSTRUCTIONS IMPORTANT DreamLine TM reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical

More information

H 12 Heavy Duty Modern Tripod 8 Seat Swing Heavy Duty Hangers

H 12 Heavy Duty Modern Tripod 8 Seat Swing Heavy Duty Hangers Page 1 IMPORTANT Please retain this instruction sheet in your files. It contains important replacement parts information. All equipment should be installed in accordance with these instructions. It is

More information

BIN LINER INSTALLATION MANUAL IMPORTANT!

BIN LINER INSTALLATION MANUAL IMPORTANT! BIN LINER INSTALLATION MANUAL IMPORTANT! Bins with 44 seam spacing require drilling of the liner and the bin & additional rows of bolts between existing seam rows. CAUTION Edges may be sharp, wear gloves

More information

Aero Tec Models 700 & 750 (115 vac)

Aero Tec Models 700 & 750 (115 vac) Aero Tec Installation Guide Aero Tec Models 700 & 750 (115 vac) A Product of 340 Gateway Park Drive North Syracuse, NY 13212 Phone: 315-463-7348 Toll Free: 866-235-7468 Fax: 315-463-8559 Email: sales@dlmanufacturing.com

More information

CURTAINWALL DEFLECTION SOLUTIONS

CURTAINWALL DEFLECTION SOLUTIONS l l l l l CURTAINWALL DEFLECTION SOLUTIONS Provides lateral support for curtain wall systems. One of the highest tested load capacities available. Direct attachment to web and support. Most clips are reversible.

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.

More information

Basic Suspension Systems

Basic Suspension Systems CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system

More information

where high efficiency is the standard

where high efficiency is the standard Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

B-500 / B-600 SERIES

B-500 / B-600 SERIES B-500 / B-600 SERIES VAPOR VENT TRANSITION INSTALLATION GUIDE SINGLE WALL VENT TRANSITION SUMPS B-500 VENT TRANSITION SINGLEWALL SERIES SHOWN WITH WATERSPLASH LID, AND SUPPORT FOR 5 VENT LINES. B-500 SINGLEWALL

More information

Good Husband Brand Remote Lighting Lifter

Good Husband Brand Remote Lighting Lifter Good Husband Brand Remote Lighting Lifter National Patent Number:200520069085.5 200520075680.X 200520075677.8 200520075679.7 International Patent Number: PCT/CN2006/000409 Product Standard: Q/QABC002-2009

More information

BoSS Climalite Camera and lighting tower

BoSS Climalite Camera and lighting tower Contents Safety First Safety First Quantity Schedules Toeboard 2 9 13 33 INTRODUCTION Please read this guide carefully. Please note that diagrams are for illustrative purposes only. User guides are also

More information