1 Evolution Radiant panel system LPHW up to 90 C Suspended ceiling grid or soffit mounting Vertical wall surface mounting Standard widths 150mm to 900mm 1

2 Description Introduction Evolution by Dunham-Bush is an architectural radiant panel system, ideal for application in light industrial or commercial buildings. It is designed for use with low temperature hot water on either constant or variable temperature circuits. The unique heating effect from Evolution radiant panels will create comfort conditions at lower design air temperatures. Room occupants are heated directly, without the need to heat the air surrounding them. Evolution can be installed in suspended ceilings, directly onto wall or ceiling surfaces or hung from drop rods. It is modular, giving the system designer great flexibility in selecting panels for any application. The standard finish is white polyester powder, but other finishes are available from the RAL or BS 4800 ranges. Authority It is accepted practice and policy at Dunham-Bush to maintain exceptional standards in engineering and quality. To this end, Dunham-Bush operates a quality system and is registered as a company of assessed capability to BS EN ISO 9001 : A one tube Evolution radiant panel consists of an aluminium alloy extruded plank, which has a plane radiating surface on one side and a semi-circular groove on the opposite side. A 15mm O.D. copper tube is retained in the groove by an extruded tube clamp, which completely encapsulates the tube. Planks are assembled and interlocked, side by side, to produce multi-tube panels. Standard Range The range consists of one, two, four and six tube panels, in nominal lengths of 600mm to 3000mm, and in various tube configurations, as illustrated in the panel diagrams. All panels can be supplied in a range of styles, to suit the applications pictured below. Style CG for suspended ceiling grid with lay-in tiles Style CS for ceiling surface or soffit mounting Style FS for suspension from roof/ soffit or steelwork Style WS for mounting onto vertical walls 2

3 Style CG (Ceiling Grid) For installation into suspended ceiling grids with lay-in type tiles. Can also be installed into solid plasterboard ceilings with perimeter trim. Style FS (Free Suspended) For installation into open roof or celiing voids. Can be hung from threaded drop rods or suspension wire systems. Style CS (Ceiling Surface) Surface mount option from solid ceiling of soffit. Fully accessible from below. Style WS (Wall Surface) Vertical wall surface mount option. Can be installed at an angle in a cornice configuration. 3

4 Style CG General Arrangement 4

5 Style CG Panel Types 5

6 Style CG Panel Runs 6

7 Style CG Sections - 1 Tube & 2 Tube Panels 7

8 Style CG Sections - 4 Tube & 6 Tube Panels 8

9 Style CG Suspension Locations 9

10 Style CG Panel Connections 10

11 Style CS General Arrangement 11

12 Style FS General Arrangement 12

13 Style WS General Arrangement 13

14 Style CS, FS & WS Panel Types 14

15 Style CS, FS & WS Panel Runs 15

16 Style CS, FS & WS Sections - 1 Tube & 2 Tube Panels 16

17 Style CS, FS & WS Sections - 4 Tube & 6 Tube Panels 17

18 Style FS Suspension Locations 18

19 Style CS, FS & WS Panel Connections 19

20 Performance Total heat outputs, Watts per metre of nominal panel length Mean water ( C) Ambient air temperature ( C) Rated Thermal Output (W/m) Styles CG CS & FS (BS EN 14037) Style WS (BS EN 442) 1T 2T 4T 6T 1T 2T 4T 6T Performance equation where Q = rated thermal output per unit area (W/m²) Styles CG CS & FS (BS EN 14037) Style WS (BS EN 442) Q = K d DT n K d n Notes 1. Thermal outputs are rated as defined in the relevant standard and are both radiant and convective. 2. Styles CG CS and FS; ~60% or total output is radiant; Style WS; ~53% of total output is radiant. 3. Outputs for Styles CG CS and FS are rated to BS EN Parts 1, 2 and 3, BS EN applies for horizontally mounted panels only. 4. Outputs for Style WS are rated to BS EN 442 Part Performance equation Q = K d DT n Where Q = rated thermal output (W/m 2 ) K d = output factor, n = output exponent DT = mean water temperature less ambient air temperature (K) 20

21 Notes: 1. Where a single panel type ED is used, the minimum water mass flow rate should not be less than kg/s, to obtain the rated output. 2. Where two or more panels are joined together to form a run, the minimum mass flow rates listed in the table must be observed, to prevent air locking. 3. The circuit length for any run can be calculated from the number of tubes per panel, the lengths and panel types and the quantity of panels being used. The pressure loss per circuit can be obtained from the graph below, which includes a nominal allowance for bends and fittings. Minimum water mass flow rates Circuit length L metres Minimum flow rate kg/s L > L > L L < The maximum recommended flow rate per circuit is 0.141kg/s (1.0m/s). Approximate dry masses of Evolution (kg) 1 Tube 2 Tube 4 Tube 6 tube Mass per Style Style Style Style metre (kg) CG CS,FS,WS CG CS,FS,WS CG CS,FS,WS CG CS,FS,WS Note: Masses exclude additional angle brackets used on wall mounted applications Pressure drop (Pa/m) per tube or circuit; check layout drawing for no. of circuits. 21

22 Application Comfort conditions It is recommended that for radiant heating systems, comfort conditions are achieved when dry-bulb air temperature is slightly lower than mean radiant temperature. This difference between the two temperatures will result in the desired operative temperature. The heat loss of the room under consideration may be calculated in accordance with CIBSE Guide A Environmental Design. Evolution is intended for operation with LTHW. The maximum recommended flow temperature is 90 C. Selection The following guidelines are to assist the designer in deciding the best layout for Evolution 1. The total heat load of the room must be calculated in accordance with recognised practice. Heat loads should be calculated using the internal design air temperature (dry bulb). However, the internal design air temperature can be reduced since mean radiant temperatures are elevated by radiant heating. 2. The total heat load should be divided by the total heat output per metre,. This will then give the require overall length of 1 tube, 2 tube, 4 tube or 6 tube radiant panels. Vertical panels will give greater heat output, which arises from greater convective heat transfer from the panel surface. 3. The run layout should then be decided, and is best set out on a layout plan. Radiant panels should be located around the outside perimeter of the room, particularly near windows. This will counteract disproportionately high heat losses. 4. There is no maximum mounting height for Evolution. However, when mounting heights exceed 4m, the heat load should be adjusted to additional losses of radiant heat incident on the walls. 5. There is no minimum mounting height for Evolution. As a rule of thumb, mounting heights should be not be lower than 2.4m. Contact Dunham-Bush for further advice on mounting heights and mean radiant temperatures. 6. Expansion panels must be used for longer panel runs, using the following guidelines :- 4 tube panels one expansion joint every 6m 6 tube panels one expansion joint every 3m 7. Ceiling Grid Applications Evolution Style CG is designed to fit into conventional lay-in tile ceiling grids; panel dimensions have been optimised so that panel edges are concealed by standard ceiling grid T-bars - typically 15mm or 24mm. 8. Plaster Board Ceiling Applications Evolution Style CG can be installed flush into a plasterboard ceiling, with typical edge trims by others; builders work should include access for commissioning and maintenance. 9. Surface Applications For other types of ceiling, Style FS or Style CS panels may be more appropriate. Style WS panels are designed for vertical wall surface applications. Evolution style FS installed into a pitched ceiling of community centre 22

23 Solid Ceilings Detail of Evolution Style CG installed flush mounted into plasterboard ceiling Evolution Style CS installed into a pitched plasterboard ceiling 23

24 Special Installations Special angle bracket installation for Evolution Style WS Evolution Style WS installed onto special angle brackets (angle to suit project requirement) 24

25 Engineering Specification The Evolution radiant heating panels shall be manufactured by Dunham- Bush Limited, Downley Road, Havant, Hampshire PO9 2JD. The style, panel types, lengths and quantities shall be as detailed in the schedule or as shown on the drawings. Styles Evolution radiant panel style shall be suitable for the selected application. Style CG ceiling grid Style CS ceiling surface Style FS freely suspended Style WS wall surface Panel types Evolution radiant panel types shown in the panel types diagram, suitable for the hydraulic circuit specified and shall be selected from the following list: Type EA standard panel Type EB end panel Type EC connection panel Type ED single panel Type EE expansion panel Type EF multi-circuit panel 22mm conn. Type EG dummy panel (no tubes) Type EH15 flow panel 15mm conn. Type EH22 flow panel 22mm conn. Type EJ15 return panel 15mm conn. Type EJ22 return panel 22mm conn. Composition Evolution radiant panels shall comprise one, two, four or six extruded aluminium alloy planks, which shall have a plane radiating surface on one side and semi-circular groove on the opposite side. A 15mm O.D. copper tube to EN1057, shall be retained in the groove by extruded tube clamps, which shall completely encapsulate the tube. The edges of the extrusion shall be tongued and grooved. Multi tube panels shall be assembled from extruded planks, interlocked side by side, securely joined by galvanised braces. Tube joints shall be soft soldered and panels shall be fitted with manual air vents, as appropriate to the panel circuitry. Where two or more panels are to be joined together, slip couplings shall be provided at tube joints. Expansion panel type EE shall be supplied with expansion hoses, as appropriate to the number of tubes. Style CG Evolution panels shall be fitted with suspension brackets. Where two or more panels are to be joined together, connector plates and joint strips shall be supplied. 50mm thick mineral wool or equal, aluminium foil faced thermal insulation, shall be provided loose for site fitting. Styles CS,FS and WS Evolution panels shall be supplied with top and bottom side rails for fixing together on site. Finish All panels and accessories shall be degreased before powder coating, colour RAL 9010, 30% gloss. Site test and working pressure Maximum cold test pressure 10.5 bar gauge, Maximum working pressure 7.0 bar gauge at 90 C, Note: higher pressures can be accommodated using silver soldered joints. Consult Dunham-Bush for details. Style CG, ceiling grid Style CG, ceiling grid Panel nominal lengths All styles and types, except corners. Panel nominal lengths shall be as detailed in the following list: 600, 900, 1000, 1200, 1500, 1800, 2000, 2100, 2400, 2500, 2700 and 3000mm. 25

26 Construction Handling The purchaser is responsible for offloading. Radiant panels can usually be lifted by two persons, but longer panels may require a third person providing support in the middle. Panels and accessories are usually palletised and shrinkwrapped, so fork lift truck or similar form of lifting equipment is required. Care should be taken to ensure panels are not dropped or suffer impact in any circumstances. Storage Radiant panels should be stored under clean, dry indoor conditions. Any packaging should not be removed until panels are ready for installation, unless damage in transit is suspected. Note the purchaser must examine the panels promptly upon receipt and any claims for damage will only be accepted if, at the time of delivery, the delivery note is endorsed with a note detailing the damage and countersigned by the transport company. Each panel may be marked with a stencil reference if specified on the order. Preparation Extensive modification to the building fabric should not normally be necessary. However, proper provision for fixings must be arranged. The structure to which the panels are to be fixed must be fit for purpose and be capable accepting drop rods or similar suspension fixings. Allowance must be made for the panels to expand freely. Style CG (ceiling grid) panels should be suspended from M6 drop rods with washers and nuts. Other suspension methods may be used. Contact Dunham-Bush for guidance. Styles CS (ceiling surface) and WS (wall surface) bottom side rails and back side rails should be screwed or bolted to a sound, flat horizontal or vertical surface (fixings not supplied). Style FS (free suspended) panel is suspended directly from drop rods or similar (not supplied). Note : It is important to coordinate the installation of panels with other trades, especially when Evolution radiant panels are to interface with other fittings such as ceilings and soffits. Pipework Connections Evolution radiant panels are supplied with pipe circuitry prepared at factory hence only flow, return and panel-joint connections are required. All panels will accept fittings for 15mm or 22m copper tube. It is recommended that connection pipework is given sufficient flexibility to allow for thermal expansion. Installation Radiant panels are supplied with assembly and installation Instructions, which provide full details on installing, connecting and commissioning radiant panels. Additional copies are available upon request. N.B. All panels are fitted with protective film on the radiating surface, which should not be removed until installation is complete and there is no risk of damage. Style CS, FS and WS panels are supplied in kit form and require assembly on site. 26

27 Supply Prices Dunham-Bush do not issue price lists, but will be pleased to provide a written quotation upon request. All quotations are normally prepared by a member of our national network of sales agents and representatives. For further details, please contact Dunham-Bush head office in Havant, Hants. Conditions of sale Standard conditions of sale are included on the reverse of all order acknowledgements. Further copies are available upon request. Availability Evolution radiant panels are supplied direct from the Dunham-Bush factory in Havant. All panels are made to order, and availability can vary with demand and should therefore be checked at the time of ordering. Contact a Dunham- Bush sales agent/ representative for typical lead times. Packaging Evolution radiant panels are packed for storage in dry, indoor conditions. If specified, each panel will be marked with its own unique stencil reference for on-site identification. Ordering To ensure the rapid processing of your order, please refer to the relevant quotation and appropriate correspondence. Please send your order directly to the Dunham-Bush sales agent/representative who provided the quotation. Dunham-Bush will prepare a detailed layout drawing of the proposed installation for approval prior to manufature. 27

28 Manufacturer reserves the right to change any product specification without notice Dunham-Bush Ltd Downley Road Havant Hants PO9 2JD Tel Fax B MAY

system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0)

system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0) metal ceilings system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0) 118 929 0900 www.sasint.co.uk system 200 information System Description SAS System 200 is a range of square,

More information

STANDARD PRODUCTS - CUSTOM LOOK

STANDARD PRODUCTS - CUSTOM LOOK AXIOM ClOUDS STANDARD PRODUCTS - CUSTOM LOOK AXIOM AXIOM can give your next space a unique and crisp feel. The AXIOM family offers dramatic visuals with a variety of flat vertical trims and design profiles.

More information

DICTATOR Lift Shaft System

DICTATOR Lift Shaft System DICTATOR Lift Shaft System The Modular Lift Shaft System, also for Retrofitting Certified According to EN 1090 A lift is becoming more and more important for daily life, not only in newly constructed buildings

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA1 Ultra Acoustical, STC 45/46, Omni, Glass Wall PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional s Manually Operated Maximum Opening Height: 12'

More information

SMART HD Radiant Panel

SMART HD Radiant Panel SMART HD Radiant Panel www.merriottuk.com www.merriott.ie What does Merriott stand for? We strive to provide bespoke heating and cooling solutions that are the better choice for commercial applications

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PRODUCT OVERVIEW: Top Supported Center Stack Paired s Manually Operated Maximum Opening Height: 12' 2 [3.7m] Maximum

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

AEROFOILS 200AF-450AF. Sun Control Systems

AEROFOILS 200AF-450AF.  Sun Control Systems AEROFOILS 200AF-450AF www.luxalon.com Sun Control Systems Luxalon Aerofoils 200AF - 450AF System Description Luxalon wing-shaped panel elements, or fins, combine optimum solar effectiveness with a firm

More information

Planning and installation instructions

Planning and installation instructions Planning and installation instructions Stofix Oy Ahlmaninkatu 2 E 40100 Jyväskylä Finland stofixgroup@stofix.com www.stofix.com 2 PLANNING AND INSTALLATION INSTRUCTIONS... 1 1 General... 3 2 Project Design...

More information

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS Buyer s Guide HOMES 1300 985 110 LIVING SUPPORT SOLUTIONS 2 BCDS0868 Contents Just imagine the space you can create 4 More reasons to choose SmartSpace 8 SmartSpace Project Planner 9 Design your SmartSpace

More information

Safety Barrier Solutions

Safety Barrier Solutions S E P A R A T I N G P E O P L E F R O M H A Z A R D S Safety Barrier Solutions SOLUTIONS TO YOUR BARRIER NEEDS SIMPLE TO DESIGN AND SPECIFY UNRIVALLED TECHNICAL SUPPORT WORLDWIDE AVAILABILITY The Kee Safety

More information

Fire Protection Valves

Fire Protection Valves 4/4/EN/6 Fire Protection Valves Type FV-K90 FVZ-K30 with German Test Certificate (General Building Approval) Z-41.3-317 Z-41.3-319 TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/202-265 Heinrich-Trox-Platz

More information

FREESTAND ROOF GUARDRAIL. Lockinex. ea i, ea u i

FREESTAND ROOF GUARDRAIL. Lockinex. ea i, ea u i FREESTAND ROOF GUARDRAIL Lockinex ea i, ea u i INTRODUCTION Lockinex Freestand Roof Guardrail system utilises Lockinex Key Clamps,Tubing & concrete counterweights seated on rubber mats and does not require

More information

ACBC Floor Mounted Active Beam

ACBC Floor Mounted Active Beam Floor Mounted Active Beam The Price Floor Mounted Active Beam,, is designed for occupant comfort. It provides high cooling and heating capacities while simultaneously supplying ventilation air from a DOAS

More information

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

A. This Section includes acoustical panel ceilings installed with exposed suspension systems. SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION ACOUSTICAL PANEL CEILINGS

SECTION ACOUSTICAL PANEL CEILINGS SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Model 4010 Individual Panels / Curve & Diverter

Model 4010 Individual Panels / Curve & Diverter Model 4010 Individual Panels / Curve & Diverter Introduction: The following three (3) part specification offers the Standard and Optional features for the Model 4010 Curve & Diverter Operable Wall System.

More information

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

2000 POCKET DOOR TECHNICAL DATA

2000 POCKET DOOR TECHNICAL DATA 2000 POCKET DOOR TECHNICAL DATA KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 2000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose

More information

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED BI-FOLD GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

ROCKFON SYSTEM ULTRALINE E

ROCKFON SYSTEM ULTRALINE E System description ROCKFON SYSTEM ULTRALINE E Visible grid ceiling system SYSTE F unctional recess allows for the easy integration of partitions, track lighting and signage E15S8 EDGE WAR YEARS IT LIM

More information

CI/SfB (23) Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Joist end Fitting Aluminium Foil Bubble Insulation General Purpose Insulation Dry Lining Insulation

More information

BoSS Climalite Camera and lighting tower

BoSS Climalite Camera and lighting tower Contents Safety First Safety First Quantity Schedules Toeboard 2 9 13 33 INTRODUCTION Please read this guide carefully. Please note that diagrams are for illustrative purposes only. User guides are also

More information

CASSETTE BS Specification book

CASSETTE BS Specification book CASSETTE BS Specification book Edition: April 2011 ArcelorMittal Construction International Industriestrasse 19 8112 Otelfingen / Zürich Switzerland www.arcelormittal.com/arval PRESENTATION OF THE SYSTEM

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

CORNER ELEMENTS CENTRE SUPPORT ACCESSORY BAG PROJECTION SCREEN BAG. 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional)

CORNER ELEMENTS CENTRE SUPPORT ACCESSORY BAG PROJECTION SCREEN BAG. 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional) FULLWHITE MANUAL CORNER ELEMENTS 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional) CENTRE SUPPORT Consists of plug in elements with integrated screw connection ACCESSORY BAG Yellow

More information

A-Series Aluminum Gantry Crane

A-Series Aluminum Gantry Crane SPANCO PRODUCT SPECIFICATIONS 1 A-Series Aluminum Gantry Crane This guide can be used to prepare a bid specification for the incorporation of an A-Series Gantry Crane into a competitive bid project or

More information

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System. Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Aluminium Foil Bubble Insulation Joist end Fitting General Purpose Insulation Dry Lining Insulation System

More information

LindabCarat. Chilled beam. lindab we simplify construction

LindabCarat. Chilled beam. lindab we simplify construction lindab we simplify construction Lindab 08.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

Trench Duct Class Catalog 5230CT9601R10/08

Trench Duct Class Catalog 5230CT9601R10/08 5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11

More information

Sandwich panel SPA Product description

Sandwich panel SPA Product description Sandwich panel SPA Product description Ruukki offers a sandwich panel system that combines an attractive appearance with excellent thermal insulation and fire-resistance. The panels are of a lightweight,

More information

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling Metal ceilings Why metal ceilings Metal ceilings are different. The density of their surface and the aesthetic restraint of their design offer the architect and builder particular creative options and

More information

Optima Vector Plank. Installation Instructions. Ceiling

Optima Vector Plank. Installation Instructions. Ceiling Ceiling Systems Between us, ideas become reality Optima Vector Plank Installation Instructions 1. GENERAL 1.1. Product Description The Vector products referenced in these instructions are made from fiberglass.

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated

More information

Rondo duo. Two-Way Exposed Suspended Ceiling Grid System. revised: august 2008

Rondo duo. Two-Way Exposed Suspended Ceiling Grid System. revised: august 2008 Rondo duo Two-Way Exposed Suspended Ceiling Grid System revised: august 2008 design considerations general information All components of the Rondo DUO Exposed Ceiling Grid System have been designed and

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

Cold Rooms Kide

Cold Rooms Kide COLD ROOMS Cold Rooms 2 Cold under control KIDE it is a business Group manufacturer of cold-rooms, insulation panels, insulated doors, refrigeration units and drying units, offering integral solutions

More information

For inhibiting the spread of fire and smoke in concealed spaces

For inhibiting the spread of fire and smoke in concealed spaces ZERO ODP ZERO GWP CI/SfB Km1 July 2005 (replaces July 2004 issue) (K22) OZONE DEPLETING POTENTIAL GLOBAL WARMING POTENTIAL Construction type Cavity Barriers Cert. N o. 022c Rockwool supports FIRAS accredited

More information

PORTISO is a company dedicated to the manufacturing of isothermal doors built to satisfy the different needs of any industrial sector.

PORTISO is a company dedicated to the manufacturing of isothermal doors built to satisfy the different needs of any industrial sector. PORTISO is a company dedicated to the manufacturing of isothermal doors built to satisfy the different needs of any industrial sector. We have modern manufacturing facilities in France, UK and Portugal,

More information

BISON PRECAST FLOORING SPECIFICATION

BISON PRECAST FLOORING SPECIFICATION BISON PRECAST FLOORING SPECIFICATION 1.0 SCOPE OF THE SPECIFICATION 1.01 Relates to: This specification covers the design, manufacture and associated site work of the following types of floors:- Hollowcore

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

Hygienic cladding solutions. the complete internal cladding solution

Hygienic cladding solutions. the complete internal cladding solution Hygienic cladding solutions the complete internal cladding solution Hygienic cladding range overview Our range of sheets, prof iles and adhesives are made to industry leading standards to meet all customer

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 095113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. AC: Articulation

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

Steelwork and Security Kiosks

Steelwork and Security Kiosks Steelwork and Security Kiosks Staircases, Fire Escapes and Ladders 282 Handrails and Guardrails 283 Platforms and Flooring 284 Fencing 285 Kiosks 286 Cages 287 Bar Sets and Grilles 288 Ancillary Items

More information

General technical terms and conditions of TAIM e.v. for. M e t a l c e i l i n g s

General technical terms and conditions of TAIM e.v. for. M e t a l c e i l i n g s General technical terms and conditions of TAIM e.v. for M e t a l c e i l i n g s November 2009 Foreword The general technical terms and conditions have been prepared under the guidance of the technical

More information

Hybrid systems. a new concept in composite facade and window systems

Hybrid systems. a new concept in composite facade and window systems HEAD OFFICE Senior Architectural Systems Ltd, Eland Road, Denaby Main, Doncaster, South Yorkshire, DN12 4HA. Tel: 01709 772 600. Fax: 01709 772 601. E-mail: info@seniorhybrid.co.uk BRANCHES Scotland; Unit

More information

Smarter. Safer. Leaner.

Smarter. Safer. Leaner. Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter

More information

where high efficiency is the standard

where high efficiency is the standard Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

SYSTEMS 03/2013. Between us, ideas become reality. Mesh Metal Ceiling

SYSTEMS 03/2013. Between us, ideas become reality. Mesh Metal Ceiling CEILING&wall SYSTES CI/SfB (35) y 03/2013 Between us, ideas become reality esh etal Ceiling KD RL 9010 KD RL 9006 KD RL 9007 KD RL 9005 RB25 RL 9010 RB25 RL 9006 RB25 RL 9007 RB25 RL 9005 RB35 RL 9010

More information

SYSTEM S7-RHOMBOS INSTALLATION MANUAL

SYSTEM S7-RHOMBOS INSTALLATION MANUAL SYSTEM S7-RHOMBOS INSTALLATION MANUAL GENERAL INFORMATION GENERAL INFORMATION This assembly manual addresses all metal ceilings manufactured by durlum. The different sections describe the related/relevant

More information

ELECTRO-FENCE. Fence Protection System. System Manual. EF_System_V1.1

ELECTRO-FENCE. Fence Protection System. System Manual. EF_System_V1.1 ELECTRO-FENCE Fence Protection System System Manual EF_System_V1.1 Advanced Perimeter Systems Ltd., 16 Cunningham Road, Springkerse Industrial Estate, Stirling, FK7 7TP Tel: +44 (0) 1786 479862 Fax: +44

More information

CEILING & WALL SYSTEMS

CEILING & WALL SYSTEMS CEILING & WALL SYSTEMS Axiom Perimeter Trim Commercial Ceilings and Walls Solutions Guide Axiom Perimeter Trim AXIOM Trim The Axiom family of products provide functional and visual options in ceiling design.

More information

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification

More information

RMF Intercell. NBS Specification 2013 K41

RMF Intercell. NBS Specification 2013 K41 RMF Intercell NBS Specification 2013 K41 InterfaceFLOR BV. K41 Specification 40mm, 60mm, 80mm, 90mm and 110mm K41 Raised access floors To be read with Preliminaries/ General conditions. TYPES OF RAISED

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

E-Series Steel Gantry Crane

E-Series Steel Gantry Crane SPANCO PRODUCT SPECIFICATIONS 1 E-Series Steel Gantry Crane This guide can be used to prepare a bid specification for the incorporation of an E-Series Gantry Crane into a competitive bid project or application.

More information

Steelwork and Security Kiosks

Steelwork and Security Kiosks Steelwork and Security Kiosks Staircases, Fire Escapes and Ladders 282 Handrails and Guardrails 283 Platforms and Flooring 284 Fencing 285 Kiosks 286 Cages 287 Bar Sets and Grilles 288 Ancillary Items

More information

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work. SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16 long / 1/2 thick or 16 oz. copper Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)

More information

ACBC Floor Mounted Active Beam

ACBC Floor Mounted Active Beam Floor Mounted Active Beam The Price Floor Mounted Active Beam,, is designed for occupant comfort. It provides high cooling and heating capacities while simultaneously supplying ventilation air from a DOAS

More information

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS ARCHITECTURAL FABRICATIONS PRODUCT BROCHURE Feature Beam Anodised Products Rainscreen Panels Fascia Panels & Soffits Ultima Insulated Panels Perforated Panels Cills, Fins & General Pressings Column Covers

More information

» Bolted system. the flexible classic. Plug-in system Bolted Office shelving Wide-span shelving Pallet racking Cantilever racking.

» Bolted system. the flexible classic. Plug-in system Bolted Office shelving Wide-span shelving Pallet racking Cantilever racking. Plug-in system Office Wide-span Plug-in system Bolted Office Wide-span system» the flexible classic 112 System overview 114-11 Complete units Shelving systems 118-123 MULTIplus shelves 124-12 Angle profiles

More information

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC. PART 1: GENERAL 1.01 Section Includes: 1. Vertical reciprocating conveyor, Hydraulic straddle VRC. a. Machine, controller, platform, structural steel hoist frame. b. Wire mesh enclosure and gates. Related

More information

Sound-absorbing and sound-insulating barriers

Sound-absorbing and sound-insulating barriers Sound-absorbing and sound-insulating barriers innovative and biocompatible solutions for the environment sound-insulation Sound-absorbing and sound-insulating noise barriers for road and rail traffic are

More information

NASSAU Panorama. Showrooms. NASSAU Panorama 4.1. You know the Quality

NASSAU Panorama. Showrooms. NASSAU Panorama 4.1. You know the Quality 4.1 Showrooms has been designed specially for buildings where a lot of natural light is required, as the windows do not have any vertical bars. The door appears elegant with its clean lines and lets lots

More information

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION DECORATIVE METAL AND GLASS RAILING SECTION 05 73 00 DECORATIVE METAL AND GLASS RAILING PART 1 GENERAL 1.1 SUMMARY A) This section includes both standard and custom handrails as shown in the contract drawings. B) These include aluminum,

More information

BAY POLES FOR LOAD BEARING WINDOWS

BAY POLES FOR LOAD BEARING WINDOWS BAY POLES FOR LOAD BEARING WINDOWS From Nicholls & Cooke The Pole Calculations Ordering Head and Base Plates New Build Box Support Anti Bounce Bars Universal Poles Slack Adjuster Kits Deceurninck Series

More information

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW PRODUCT OVERVIEW FIXFAST USA Providing maximum safety with minimum fuss to workers at height. Our extensive range of safe access products and fall protection systems are designed for industrial, commercial

More information

BENCHMARK Evolution Axis

BENCHMARK Evolution Axis Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL

More information

PORTA-FAB Cleanroom Wall Systems

PORTA-FAB Cleanroom Wall Systems PORTA-FAB Cleanroom Wall Systems FABLINE FURRING 500 INSTALLATION INSTRUCTIONS IMPORTANT Porta-Fab Advises A Thorough Reading of These Instructions Before Beginning Installation. INTRODUCTION Porta-Fab

More information

HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION

HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION INSTRUCTION MANUAL ENERGY AND SANITARY SYSTEMS Installation requirements General requirements The free-standing installation set is to be used or installing

More information

An innovative and versatile concept offering countless solutions for all your storage needs from simple single bays to multi-tier installations.

An innovative and versatile concept offering countless solutions for all your storage needs from simple single bays to multi-tier installations. S T E E L S H E E T S H E L V I N G An innovative and versatile concept offering countless solutions for all your storage needs from simple single bays to multi-tier installations. Technical characteristics:

More information

Rondo DUO. Two-Way Exposed Suspended Ceiling Grid System

Rondo DUO. Two-Way Exposed Suspended Ceiling Grid System Rondo DUO Two-Way Exposed Suspended Ceiling Grid System DESIGN CONSIDERATIONS GENERAL INFORMATION All components of the Rondo DUO Exposed Ceiling Grid System have been designed and tested by Rondo engineers

More information

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector mm M0-.5 Turnbuckle connections to structural steel 30mm Perimeter Extrusion Simple supported 4 screw assembly and vertically supported flanged grid 750 Montevideo Road Tel (40)799-4200 Main Runner with

More information

mounting systems applications overview

mounting systems applications overview mounting systems applications overview catalogue version January 2015 tritec mounting systems: overview of applications i. pitched roof: roof-top 1. Tiles, shingles and corrugated panels 1.1 TRI-STAND

More information

ALL-ALUMINUM DOOR & WINDOW FRAMING

ALL-ALUMINUM DOOR & WINDOW FRAMING ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum

More information

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West Exposition East West CONTENTS 1 Notes on the Sika SolarMount 1 system (Exposition East West) for PV solar arrays 3 2 Setting up on site 3 3 Required Tools for mounting Sika SolarMount 1 to Sika roofing

More information

Movable Acoustic Walls for Flexible Space

Movable Acoustic Walls for Flexible Space GOOD AFTERNOON AND A WARM WELCOME TO THE PRESENTATION on MOVEABLE WALLS FOR FLEXIBLE SPACE Simon Borley Senior Sales Manager Company History Company History: The Longest running Company in UK History founded

More information

ARMSTRONG SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY OF ITS GUIDE SPECIFICATIONS. SECTION PERIMETER TRANSITION SYSTEM

ARMSTRONG SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY OF ITS GUIDE SPECIFICATIONS. SECTION PERIMETER TRANSITION SYSTEM Armstrong World Industries, Inc. Please understand that you are responsible for the accuracy of all project specifications, including any Armstrong Ceilings guide specifications that you use. ARMSTRONG

More information

PATHWAYS FOR COMMUNICATIONS SYSTEMS

PATHWAYS FOR COMMUNICATIONS SYSTEMS 270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This

More information

Locrete Building System: the Technology Handbook

Locrete Building System: the Technology Handbook Locrete Building System: the Technology Handbook 1 3... Introduction 4... Characteristics 6... Locrete Production 8... Locrete Testing 12... Building with Locrete 16... Shuttering System 13... External

More information

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS PART 1 GENERAL 1.01 SUMMARY Specifier Note: Revise paragraphs below to suit project requirements. A. Section Includes: Custom fabricated acoustical

More information

Sika KAB combination joint waterbars waterstopping systems

Sika KAB combination joint waterbars waterstopping systems PRODUCT DATA SHEET Sika KAB combination joint waterbars Waterbars for waterproofing construction and crack induced shrinkage joints in new reinforced concrete structures PRODUCT- DESCRIPTION KAB 125/KAB

More information

MILT-Pro. Built-in units and control centres for halls

MILT-Pro. Built-in units and control centres for halls MILT-Pro Built-in units and control centres for halls Space The MILT-Pro built-in units provide its design solution offer a large range of applications in commercial, manufacturing and warehouse spaces.

More information

Hygienic Cladding Solutions. White, Pastel & Vibrant Colours. Satin & Gloss Ranges

Hygienic Cladding Solutions. White, Pastel & Vibrant Colours. Satin & Gloss Ranges Hygienic Cladding Solutions White, Pastel & Vibrant Colours Satin & Gloss Ranges The complete cladding solution. A quality, cost efficient, high performance hygienic wall and ceiling system that you can

More information

Multi-layer Insulation Blanket for use in Walls

Multi-layer Insulation Blanket for use in Walls To order Superquilt online for free delivery within the UK Mainland visit www.ecohome-insulation.com or call 0844 9919949 To order Superquilt online for delivery within Europe and pay online by Euro visit

More information

Optima Vector Ultima Vector

Optima Vector Ultima Vector CEILING&WALL SYSTEMS Between us, ideas become reality Optima Ultima Installation Instructions ceiling panel items: OPTIMA: 3900, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3909 ULTIMA: 1920, 1921

More information

Basic Suspension Systems

Basic Suspension Systems CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system

More information

Architect: Bruno Marques Photographer: AFFP Filipe Pombo TOPAZE CONTEMPORARY SLIDER

Architect: Bruno Marques Photographer: AFFP Filipe Pombo TOPAZE CONTEMPORARY SLIDER Architect: Bruno Marques Photographer: AFFP Filipe Pombo TOPAZE CONTEMPORARY SLIDER TOPAZE, sobriety, simplicity and adaptability TOPAZE+, exceptional joinery TOPAZE+ offers solutions to specific market

More information

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS Controlled Environments Controlled Environment Panel System KS1100 CS Overview Kingspan controlled environment panel systems are designed for use within temperature controlled and hygiene safe environments

More information

BRE Global Ltd Watford, Herts WD25 9XX. d+b facades (UK) Ltd. The Packway, Larkhill, Salisbury, SP4 8PY. Customer Services

BRE Global Ltd Watford, Herts WD25 9XX. d+b facades (UK) Ltd. The Packway, Larkhill, Salisbury, SP4 8PY. Customer Services BRE Global Test Report BS 8414-1:2015 + A1:2017 test on d+b facades rain screen cladding system with 100mm-thick Rockwool insulation and aluminium cassette panels. Prepared for: d+b facades (UK) Ltd. Date:

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 12 2113 - LOUVER BLINDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION DIRECTORIES

SECTION DIRECTORIES PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 13 00 DIRECTORIES SPEC WRITER NOTES: 1. Delete // // if not applicable to project. Also delete any other item or paragraph not applicable in the section and

More information

MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING

MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING CI/SfB (4-) Rh2 MAY 2006 MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING Contents Page 1.0 General 1 2.0 Methods for measuring tolerances 2 2.1 Sheet length 2 2.2 Sheet cover width,

More information

Vengen 28. There s a much bigger picture to be found at Ruskin Air Management. Double Glazed Thermal Break Louvre Window. naco.

Vengen 28. There s a much bigger picture to be found at Ruskin Air Management. Double Glazed Thermal Break Louvre Window. naco. August 2013 Vengen 28 Double Glazed Thermal Break Louvre Window l Manual Control l Motor Control l Anti-Finger Trap l Fail Safe Open / Close l Control Panels There s a much bigger picture to be found at

More information

American Metal Specialties, Inc.

American Metal Specialties, Inc. American Metal Specialties, Inc. www.cablerailings.com (253) 272-9344 (253) 627-3843 Fax PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 05 73 00 STAINLESS STEEL ORNAMENTAL HANDRAILS AND RAILINGS For best

More information