1 Penetrations For Larger Penetrations, use VaproLiqui-Flash tooled at least 2" onto the face and 2" out along all sides of the penetration Apply sufficient Dow 758 Sealant to completely seal fastener penetrations 2" Apply VaproLiqui-Flash to complex penetrations [i.e. structural elements] tooled evenly at least 2" onto the face and at least 2" out along all sides of the penetration [provide backing where needed or over ¼" gap] 2" 2" OK to apply VaproLiqui-Flash to damp substrate 2" Apply and lightly tool Dow 758 Sealant around smaller penetrations up to 1" in Diameter Gasketed Fasteners typically require no additional sealing A Vapor permeable, water-resistive, UV stable, air barrier, self-adhered membrane for open joint cladding applications with VaproLiqui-Flash vapor permeable, liquid applied flashing for penetration interfaces. Adhered) creates a complete air barrier membrane system over gypsum or plywood sheathing, concrete, and CMU wall substrates. VaproShield LLC th Ave. N.W. Suite C5 Gig Harbor, WA Toll Free: VaproShield 6/2014

2 1 RevealFlashing SA Sill Piece applied directly to sheathing + folded 2.75" inside of R.O. *Release paper left on lower 6" to shingle over field membrane 2 RevealFlashing SA Jamb Pieces applied directly to sheathing + folder 2.75" inside of R.O. 3 RevealFlashing SA Sill Pieces applied directly to sheathing + folder 2.75" inside of R.O. 4 inside rough opening + 1" on face 5 Head flashing (by others) over VaproLiqui-Flash embedded in Dow Sheathing in "as new" condition 2 VaproLiqui-Flash + RevealFlashing SA [Self Adhered] Sequencing Exploded View 6 Commercial Window sealant joint + backer rod (by others) RevealShield SA or RevealShield IT field membrane shingled over flashing [sealed w/ Dow 758 for mechanically attached Membranes] In order to maintain continuity of air barrier system, while allowing for proper drainage at sill, a continuous interior window perimeter sealant joint with backer rod is required VaproLiqui-Flash is a liquid applied, vapor permeable, waterproof, air barrier flashing system component for window and door rough openings. VaproLiqui- Flash is designed to work with RevealFlashing SA and VaproShield field membranes as a complete system. RevealShield SA or RevealShield combined with VaproLiqui-Flash + RevealFlashing help facilitate continuous air barriers behind open joint cladding applications over multiple substrate varieties. VaproShield LLC th Ave. N.W. Suite C5 Gig Harbor, WA Toll Free: VaproShield 6/2014

3 Substrate Joints RevealShield SA WRB / AB Field Membrane Sheathing in "as new" condition RevealShield SA Open Joint Field Membrane lap onto thru-wall flashing [by others] min. 3" RevealFlashing SA with VaproLiqui-Flash lap 3" min. onto horiz. surface; seal with Dow 758 Sealant and backer rod where prudent RevealShield SA WRB / AB Field Membrane VaproBatten Rain Screen Batten System

4 Change in Substrate Substrate in "as new" condition Up to 2" Wide Open Joints Note: Use VaproShims with Horiz. Cladding Attachments RevealShield SA Self-Adhered Open Joint Field Membrane Rain Screen VaproBattens System

5 Damage / Defects Dow 758 Sealant tooled or VaproLiqui-Flash top edge of reverse lap RevealFlashing SA or RevealShield SA 6" lap around perimeter of damage

6 Deflection Joint Backer rod [by others] size determined by building envelope consultant RevealShield SA or RevealFlashing SA 2 layers / min. 3" lap past joint RevealShield SA WRB / AB Open Joint Field Membrane Substrate in "as new" condition mortar joints struck flush

7 Expansion or Contraction Joint Substrate in "as new" condition RevealFlashing SA 11.75" with "loop" adhere 3" strip to center of RevealShield SA to back side: adhesive to adhesive RevealShield SA Self-Adhered Open Joint Field Membrane lap onto RevealFlashing SA min. 3" Plan View (NTS)

8 Roof to Wall SlopeShield SA lap onto flashing and/or ice & water shield ice & water shield / flashing with butyl, acrylic, or hybrid adhesive Substrate in "as new" condition RevealShield SA WRB / AB Membrane lap min. 3" in shingle fashion at all seams

9 Substrate Joints Substrate in "as new" condition Note: Use VaproShims with Horiz. Cladding Attachments Up to 2" Wide Open Joints Joints >⅜" require backing RevealShield SA Self-Adhered Open Joint Field Membrane Rain Screen VaproBattens System

10 Wall to Foundation Note: Use VaproShims with Horiz. Cladding Attachments Up to 2" Wide Open Joints RevealShield SA Self-Adhered Open Joint Field Membrane Flashing Membrane RevealFlashing SA or RevealShield SA 3" lap adhere directly to foundation

11 Window or Door Rough Opening SHEATHING IN "AS NEW" CONDITION HEAD FLASHING [BY OTHERS] SET IN DOW 758 OVER VAPROLIQUI-FLASH COMMERCIAL OR FLANGED WINDOW W/ BACKING ROD + SEALANT JOINT OR APPROVED TAPE PER WINDOW MFR. [BY OTHERS] VAPROLIQUI-FLASH CONTINUOUS INSIDE ROUGH OPENING + 1" ON FACE NOTE: INNER WINDOW TO WALL INTERFACE TO PROVIDE CONTINUOUS AIR + WATER TIGHT SEALANT JOINT WITH BACKER ROD TO FACILITATE BACK DAM EFFECT AND AIR BARRIER CONTINUITY REVEALSHIELD SA WRB/AB FIELD MEMBRANE SHINGLED UNDER SILL FLASHING PROPERLY SEQUENCED; APPLIED DIRECTLY TO SHEATHING + FOLDED 2.75" INSIDE OF R.O

12 WRB/AB FIELD MEMBRANE SHINGLED OVER HEAD FLASHING SHEATHING IN "AS NEW" CONDITION RevealShield SA Wall to Window Interface HEAD FLASHING [BY OTHERS] SET IN DOW 758 OVER VAPROLIQUI-FLASH COMMERCIAL WINDOW W/ BACKING ROD + SEALANT JOINT [BY OTHERS] INSIDE ROUGH OPENING + 1" ON FACE RevealFlashing SA PROPERLY SHINGLED; APPLIED DIRECTLY TO SHEATHING + FOLDED 2.75" INSIDE OF R.O

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS VAPROLIQUI-FLASH Liquid Applied Waterproof Flashing Material OVERVIEW VaproLiqui-Flash is a liquid applied Waterproof Flashing material for window and door rough opening interfaces. It is designed for

More information

Henry Blueskin VP160 Air Barrier System Installation Manual

Henry Blueskin VP160 Air Barrier System Installation Manual Henry Blueskin VP160 Air Barrier System Installation Manual Building Envelope Systems 1 Effective 09/28/2017 US Supersedes all previous versions Table of contents 1. Introduction...3 1.01 Air barrier considerations...3

More information

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS USER S BULLETIN MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS CONTENTS Introduction...1 Use of this Residential Multi-Family User s Bulletin...1 DuPont Multi-Family

More information

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS USER S BULLETIN SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS CONTENTS Introduction...1 Use of This Residential Single Family User s Bulletin...1 DuPont Residential

More information

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer... SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood

More information

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an

More information

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board Perimeter Relief and Control Joints in Fire-Rated Gypsum Board In multi-family residential construction, involving fire-rated assemblies stress relief in the firerated assemblies is important, but often

More information

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME

More information

How do you install yours?

How do you install yours? How do you install yours? Darrell Paul Qualistat Building Performance Consultants CSA 440 Just about adding Peel & Stick? 1 Window and door problems Photos / videos Video available for viewing at INSTAGRAM

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08

More information

BLUESKIN VP160 INSTALLATION GUIDELINES

BLUESKIN VP160 INSTALLATION GUIDELINES BLUESKIN VP160 INSTALLATION GUIDELINES Effective 09/29/2016 CA Supersedes all previous versions Table of Contents 1. Introduction... 3 1.01 Air Barrier Considerations... 3 1.02 Building Code Standards...

More information

Tensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7.

Tensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7. TECHNICAL DATA SHEET Protecto Universal Primer Free Membrane Self-adhered Flashing / Air Barrier / Vapor Retarder Thru-Wall Flashing / Below Grade Waterproofing Membrane with Super Stick technology TECHNICAL

More information

Fundamentals of Door Installation START

Fundamentals of Door Installation START Fundamentals of Door Installation START Course Description This program provides a general overview of best-practice installation procedures for wood and clad/wood doors, including a discussion on opening

More information

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide. Note: This document has been divided into several sections in order to suit the limitations of the website. The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice

More information

Tech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide

Tech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide Tech Solutions 536.0 WEATHERMATE Straight Flashing Commercial Installation Guide Table of Contents Product Overview.................................................................................3 Benefits

More information

AquaFlash System Installation Guide DS196

AquaFlash System Installation Guide DS196 AquaFlash System Installation Guide I. General: A. This document provides guidelines for the application and use of the Dryvit AquaFlash System at rough openings for windows, doors and other penetrations,

More information

Senturion TM III Wall System

Senturion TM III Wall System Senturion TM III Wall System TYPICAL DETAILS 1017666 1. Senturion III Wall System Application (Plan VIew) 2. Senturion III Wall System Application (Isometric View) 3. Aesthetic Groove (Plan VIew) 4. Insulation

More information

2006 Building Code Flashing Changes & Challenges. Builder Breakfast and Luncheon Series Presented by:

2006 Building Code Flashing Changes & Challenges. Builder Breakfast and Luncheon Series Presented by: 2006 Building Code Flashing Changes & Challenges Builder Breakfast and Luncheon Series Presented by: 1 Speakers 2006 Building Code Flashing Changes & Challenges Mick Ryan, President, Siding Contractors

More information

FMA_AAMA_WDMA Installation Committee Update FMA Conference May 8, Naples, FL. Jim Katsaros FMA_AAMA_WDMA Installation Committee

FMA_AAMA_WDMA Installation Committee Update FMA Conference May 8, Naples, FL. Jim Katsaros FMA_AAMA_WDMA Installation Committee FMA_AAMA_WDMA Installation Committee Update FMA Conference May 8, 2013 - Naples, FL Jim Katsaros FMA_AAMA_WDMA Installation Committee Representing the FMA/AAMA/WDMA Installation Coordination Committee:

More information

Managing Rainwater at the Window-Wall Interface

Managing Rainwater at the Window-Wall Interface Managing Rainwater at the Window-Wall Interface Prepared by : Silvio Plescia (CMHC) and Michael Lacasse (NRC) ANHWP, Edmonton and Calgary, 23-24 September 2009 CMHC SCHL Introduction The problems you know

More information

NEXT GENERATION HIGH PERFORMANCE WALLS

NEXT GENERATION HIGH PERFORMANCE WALLS CONSTRUCTION GUIDE NEXT GENERATION HIGH PERFORMANCE WALLS CLIMATE ZONES 3-5 PART 2: 2X4 Walls with 1" 1.5" Exterior Insulative Sheathing V. Kochkin and J. Wiehagen Home Innovation Research Labs June 2017

More information

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements Product Information & Installation Manual 01 Important Notice to Buyers and Users of RoyOMartin wall system These instructions are not intended to cover every installation requirement, application, detail

More information

Air and Vapor Barrier 3015

Air and Vapor Barrier 3015 Air and Vapor Barrier 3015 Technical Data March 2017 Product Description 3M Air and Vapor Barrier 3015 is an air, moisture and water impermeable membrane with an aggressive, high-tack acrylic pressure

More information

SURESILL WATER MANAGEMENT GUIDE

SURESILL WATER MANAGEMENT GUIDE THE SURE LEVEL OF PROTECTION SURESILL WATER MANAGEMENT GUIDE FOR WINDOWS AND DOORS *1 SLOPED SILL PAN ASSEMBLY Cut the channel plate ¼ smaller than the rough opening. Check the fit with end caps before

More information

Avoiding Air Barrier Pitfalls When sub-trade activities are not in sync with air barrier requirements, installation can go poorly.

Avoiding Air Barrier Pitfalls When sub-trade activities are not in sync with air barrier requirements, installation can go poorly. 48 D+D NOVEMBER 2013 Building Envelope Avoiding Air Barrier Pitfalls When sub-trade activities are not in sync with air barrier requirements, installation can go poorly. By Brian H. Neely, AIA, CDT, CBST,

More information

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012 FMA / AAMA / WDMA Installation Committee Update Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012 Topics for discussion. Review & Update on FMA/AAMA/WDMA Window & Door

More information

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS CHECKLIST PRIOR TO THE INSTALLATION OF BACKSTOP NT - SMOOTH AND TEXTURE Project Conditions Maximum storage

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08

More information

Magnum Board Section Digicon Information Inc. Page 1

Magnum Board Section Digicon Information Inc. Page 1 Digicon Information Inc. Page 1 This section includes sheathing for exterior walls for use in a potentially damp or wet exterior cladding environment. This sheathing section forms an exterior flat plane

More information

LP SmartSide Perfection Shingle

LP SmartSide Perfection Shingle Application Instructions Fiber Substrate Lap Siding A A - Lap Siding ON SITE STORAGE Store off the ground well supported, on a flat well-drained surface. (Diagram 1a) Additional support may be required

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX

More information

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings application instructions STRAND SUBSTRATE 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH General At the time of manufacture, siding meets or exceeds the performance standards

More information

Detail Set: Thermax Wall System Masonry

Detail Set: Thermax Wall System Masonry Dow Building Solutions Detail Set: Thermax Wall System Masonry This detail set outlines the masonry guidelines for design using the THERMAX Wall System, focusing around attachment of masonry façades and

More information

Finestone Stucco Ultra Wall System

Finestone Stucco Ultra Wall System Finestone Stucco Ultra Wall System Premium impact and puncture resistant, rain screen design cement plaster stucco system with enhanced water management Typical Details BLANK PAGE Finestone Stucco Ultra

More information

for New Construction Applications

for New Construction Applications INSTALLATION GUIDE for New Construction Applications Designing and building instructions for ThermalStar LCi are described in the following manual. General installation, fastening details and instructions

More information

DuPont RainVent Batten Installation Guidelines

DuPont RainVent Batten Installation Guidelines DuPont RainVent Batten Installation Guidelines Purpose: To improve the ventilation and draining space behind a cladding system or 3-coat stucco system in residential construction. The DuPont RainVent Batten

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS EnergyShield Continuous Wall Insulation INSTALLATION INSTRUCTIONS EnergyShield and EnergyShield CGF CONNECTING FUNCTION WITH FACILITY EnergyShield and EnergyShield CGF Installation Instructions Conditions

More information

Dow Corning DefendAir 200: Application Guide

Dow Corning DefendAir 200: Application Guide DefendAir 200: Application Guide DefendAir 200: Application Guide DefendAir 200 Application Guide Contents This document is intended to provide installation and field testing guidance for DefendAir 200.

More information

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION SECTION 093000 - SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION PART 1 - GENERAL This specification includes the sheet membrane used as waterproofing, vapor retarder, and crack isolation in conjunction

More information

OSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION

OSB.COMFORT INSTALLATION GUIDE *  1 RECOMMENDED USE PANEL COMPOSITION STYRO RAIL 07-0 Expanded Polystyrene Rigid Insulation combined to an Oriented Structural Board INSTALLATION GUIDE * 9 mm [8 ] The OSB.Comfort boards manufactured by Styro Rail are composed of type expanded

More information

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208 Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan

More information

Majrex. System Guidelines For Air Barrier and Vapor Control Installation

Majrex. System Guidelines For Air Barrier and Vapor Control Installation Majrex System Guidelines For Air Barrier and Vapor Control Installation fdsa Introduction SIGA Majrex with Hygrobrid technology is a directional, moisture-variable vapor control layer for interior roof,

More information

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer) NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS

More information

STORAGE AND TRANSPORTION

STORAGE AND TRANSPORTION Content 1. General & Notes 2. Substrate Processing 3. Panel Layout 4. Tools 5. Screws 6. Installation instructions 7. Cleaning 8. FAQS 8. MSDS General & Notes In comparison to natural or cast stone, Questone

More information

Weatherproofing & Sealing Systems

Weatherproofing & Sealing Systems Weatherproofing & Sealing Systems Weather Barrier & Waterproofing Residential & Commercial Structures New Construction, Remodeling & Repair Low Slope Roofing Membranes Roofing Underlayments Window & Door

More information

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV

More information

Armourwall Stucco Systems

Armourwall Stucco Systems Armourwall Stucco Systems Armourwall Stucco Systems Provide THE PAREX ADVANTAGE The Parex tradition of leadership in the building industry began in 1986 with a commitment to growth based on unparalleled

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3435 Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

Integrated Air & Water Barrier Systems

Integrated Air & Water Barrier Systems Integrated Air & Water Barrier Systems Presented by [ Jeff Presenter s Key, Georgia-Pacific Name ] Wood Products AIA Course: GP-FF-WRBAB Credit Designation: LU HSW Please add relevant logo here Disclaimer:

More information

Proper Installation of Insulated Metal Wall Panels

Proper Installation of Insulated Metal Wall Panels Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also

More information

1 Firestone EPDM Roofing Systems

1 Firestone EPDM Roofing Systems 1 Firestone 1. Firestone EPDM Systems To ensure a long-lasting, trouble-free roof today, it is not sufficient to manufacture high quality roofing membranes. Experience learned that roofing membranes need

More information

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY 4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS

More information

Senershield -R / Senershield -VB

Senershield -R / Senershield -VB Senershield -R / Senershield -VB Air / Water-Resistive Barrier Typical Details 1. Termination at Grade - Sheathing Overlapping Foundation 2. Termination at Grade - Sheathing Overlapping Foundation with

More information

HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING

HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING ROCCO ROMERO, RA WISS, JANNEY, ELSTNER ASSOCIATES, INC. 960 South Harney St., Seattle, Washington 98108 Phone: 206-622-1441 Fax: 206-622-0701 E-mail: rromero@wje.com

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

LUX Specifications. Section S - Preformed Steel Siding

LUX Specifications. Section S - Preformed Steel Siding Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of

More information

Installation Procedures for the Ultra Air Barrier Wall System

Installation Procedures for the Ultra Air Barrier Wall System STEEL STUD BACKUP CONSTRUCTION Installation Procedures for the Ultra Air Barrier Wall System Installation Procedures for the Ultra Air Barrier Wall System in Steel Stud Backup 1 System Overview STYROFOAM

More information

Installation Guidelines for Adhered Concrete Masonry Veneer

Installation Guidelines for Adhered Concrete Masonry Veneer Installation Guidelines for Adhered Concrete Masonry Veneer Installation Guidelines for Adhered Concrete Masonry Veneer Page 1 Contents Definitions 3 Abbreviations 3 References 4 Summary Table 5 Workmanship

More information

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera Walter Sebastian BMT Building Enviroment Consultants Ltd., Doktor Neergaards Vej 15, DK-2970 Hoersholm, Denmark

More information

Parex USA Stucco Details CSI SECTION

Parex USA Stucco Details CSI SECTION Parex USA Stucco Details CSI SECTION 09 22 00 Note: The design specifications and construction shall comply with all local building codes and standards. Parex USA installation guidelines are for general

More information

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate Colphene BSW Training and Application Guide Colphene BSW Waterproofing Membrane. 1. Prepare substrate Substrate must be structurally sound. Surface must be free of voids, spalled areas, loose aggregate,

More information

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 075423 - THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Division 00 Bidding Requirements and other Division

More information

Finestone Stucco System

Finestone Stucco System Typical Details Finestone Stucco System Cement Plaster Stucco 1. Typical Finestone Stucco System with Steel Framing 2. Typical Finestone Stucco System with Wood Framing 3. Typical Finestone Stucco System

More information

Rainscreen Gaps in Exterior Walls

Rainscreen Gaps in Exterior Walls PHRC Webinar Series Tuesday, September 13 @ 1pm Rainscreen Gaps in Exterior Walls Brian Wolfgang Housing Systems Specialist Pennsylvania Housing Research Center 219 Sackett Building University Park, PA

More information

The Original. The Innovator.

The Original. The Innovator. 50368 York MoistureControl Rev5:50368 YorkMoistureControl 9/11/08 2:33 PM Page 1 The Original. The Innovator. 50368 York MoistureControl Rev5:50368 YorkMoistureControl 9/11/08 2:33 PM Page 2 Through-Wall

More information

DRY SEAL INSTALLATION GUIDE

DRY SEAL INSTALLATION GUIDE DRY SEAL INSTALLATION GUIDE Effective September 2015 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Handling and Maintenance of Omega-Lite Panels 1 System Limitations and Pre-Installation

More information

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu INSTALLATION INSTRUCTIONS Note: The following installation instructions are based off of ASTM E 1643 (Standard Practice for Installation of Water Vapor Retarders Used in Contact with Earth or Granular

More information

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage. DELTA -DRAIN Section 07 10 00 Dampproofing and Waterproofing PART 1 GENERAL 1.1 SECTION INCLUDES A. Below grade drainage sheets. B. Plaza deck and planter drainage sheets. 1.2 RELATED SECTIONS A. Section

More information

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3914 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2045 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 07 00

More information

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board. SECTION 093000 - SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL This specification includes the sheet membrane used as waterproofing and vapor retarder, in conjunction with tile and dimension stone installations.

More information

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1474 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 06 00

More information

A. Source Limitations: Obtain each type of building insulation through one source.

A. Source Limitations: Obtain each type of building insulation through one source. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

ENGINEERING EVALUATION

ENGINEERING EVALUATION April 2017 To Whom It May Concern, Attached is the Engineering Evaluation Engineering Extensions based on 4 NFA Tests repared for Rmax Operating Refer to pages 4 and 12 to find multiple VaproShield WRB/Air

More information

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards SECTION 07185 TRAFFIC MEMBRANE PART 1 GENERAL 1.1 SECTION INCLUDES A. Traffic membrane, consisting of welded seam PVC waterproofing, over f following surfaces: 1. Decks, balconies, and sun porches 2. Walkways,

More information

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.*** ***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Clear copper and preweathered copper

More information

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market Advanced technologies for enhancing the building envelope 3M Building and Construction Market Controlling air is crucial for the health & energy efficiency of buildings Ensuring you have the right air

More information

Commercial Air Barrier Systems

Commercial Air Barrier Systems Building Envelope Systems Roofing Air Barrier Waterproofing Ask us today about other Henry solutions that help manage the flow of water, air, vapor and energy. Commercial Air Barrier Systems The industry

More information

Water Penetration Resistance - Design and Detailing

Water Penetration Resistance - Design and Detailing Technical Notes on Brick Construction 7 114 Commerce Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Water Penetration Resistance - Design and Detailing Abstract: Proper design, detailing

More information

RS32 Multi-Section Skylight System under/over seam clip double diverter

RS32 Multi-Section Skylight System under/over seam clip double diverter INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series

More information

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON ADDENDUM NUMBER FROM: MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 0 / 533 WEST MAIN STREET TUPELO, MS 3880 / 3880 FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON PHONE: -8-00 PROJECT: ACADEMIC STUDENT

More information

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions. General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions. Surface Preparation: Surface to be coated should be clean, dry and structurally sound.

More information

Building Envelope Moisture Drainage & Ventilation Products from Keene Building Products

Building Envelope Moisture Drainage & Ventilation Products from Keene Building Products Building Envelope Moisture Drainage & Ventilation Products from Keene Building Products NEW Products Driwall Rainscreen CAV-AIR-ATOR KeeneStone Cut KeedeLath Driwall Weep Screed Driwall Membrane (Flashing)

More information

RE: Exterior Wall Analysis Use of Gypsum Sheathing Over Dow Thermax Insulation in NFPA 285 Complying Wall Assemblies No. 1JJB05306.

RE: Exterior Wall Analysis Use of Gypsum Sheathing Over Dow Thermax Insulation in NFPA 285 Complying Wall Assemblies No. 1JJB05306. December 8, 2017 Dow Building Solutions The Dow Chemical Company 1605 Joseph Drive Midland, MI 48642 RE: Exterior Wall Analysis Use of Gypsum Sheathing Over Dow Thermax Insulation in NFPA 285 Complying

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

THERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240

THERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240 STUC-O-FLEX THERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary to install

More information

MID-RISE DESIGN & CONSTRUCTION

MID-RISE DESIGN & CONSTRUCTION TECHNICAL BULLETIN No.38-021616 Rev072116 MID-RISE DESIGN & CONSTRUCTION Logix effective R-values range from R-24 to R-28+ Insulated concrete forms (ICF) are becoming a main stream choice for the construction

More information

BEP Blue Barrier Installation and Application Guide

BEP Blue Barrier Installation and Application Guide BEP Blue Barrier Installation and Application Guide BEP Blue Barrier is a system of seamless fluid applied products designed to protect the building envelope. Approved assemblies and applications listed

More information

Synthetic Stucco Without Failures To avoid a lawsuit, build a drainable assembly

Synthetic Stucco Without Failures To avoid a lawsuit, build a drainable assembly BEST PRACTICES STUCCO Synthetic Stucco Without Failures To avoid a lawsuit, build a drainable assembly BY MARK PARLEE Photos: Mark Parlee I started out 38 years ago as a framing and siding contractor in

More information

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary

More information

WALL PROTECTION VIDEOS PROJECT GALLERY INSTALL GUIDES TECH SUPPORT. BenjaminObdyke.com (800)

WALL PROTECTION VIDEOS PROJECT GALLERY INSTALL GUIDES TECH SUPPORT. BenjaminObdyke.com (800) WALL PROTECTION Wall Protection Solutions from Benjamin Obdyke Water will find a way in. Most building scientists not only believe this fact, but also agree that the best way to avoid issues caused by

More information

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall

More information

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings FINEGAN INSPECTION SERVICES, INC. 27 Laurelwood Drive Milford Ohio, 45150 513 683-0733 RESIDENCE LOCATION INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings OVERVIEW The report

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00

More information

Exterior Building Materials & Detailing

Exterior Building Materials & Detailing Exterior Building Materials & Detailing Marquam George Marquam George LLC Juneau, Alaska marquamgeorge@gmail.com Barriers to? V.1950 Air only Vapor only Water only Air & Water 1 V.1990 V.2005 Detailing

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)

More information

Exterior Stucco and Siding Installation

Exterior Stucco and Siding Installation Exterior Stucco and Siding Installation CITY OF NEWARK, CALIFORNIA BUILDING INSPECTION DIVISION 37101 Newark Boulevard, Newark, CA 94560-3796 510-578-4261 Fax 510-578-4307 e-mail: building.inspection@newark.org

More information