RevealShield SA Penetrations
|
|
- Sophia York
- 6 years ago
- Views:
Transcription
1 Penetrations For Larger Penetrations, use VaproLiqui-Flash tooled at least 2" onto the face and 2" out along all sides of the penetration Apply sufficient Dow 758 Sealant to completely seal fastener penetrations 2" Apply VaproLiqui-Flash to complex penetrations [i.e. structural elements] tooled evenly at least 2" onto the face and at least 2" out along all sides of the penetration [provide backing where needed or over ¼" gap] 2" 2" OK to apply VaproLiqui-Flash to damp substrate 2" Apply and lightly tool Dow 758 Sealant around smaller penetrations up to 1" in Diameter Gasketed Fasteners typically require no additional sealing A Vapor permeable, water-resistive, UV stable, air barrier, self-adhered membrane for open joint cladding applications with VaproLiqui-Flash vapor permeable, liquid applied flashing for penetration interfaces. Adhered) creates a complete air barrier membrane system over gypsum or plywood sheathing, concrete, and CMU wall substrates. VaproShield LLC th Ave. N.W. Suite C5 Gig Harbor, WA Toll Free: VaproShield 6/2014
2 1 RevealFlashing SA Sill Piece applied directly to sheathing + folded 2.75" inside of R.O. *Release paper left on lower 6" to shingle over field membrane 2 RevealFlashing SA Jamb Pieces applied directly to sheathing + folder 2.75" inside of R.O. 3 RevealFlashing SA Sill Pieces applied directly to sheathing + folder 2.75" inside of R.O. 4 inside rough opening + 1" on face 5 Head flashing (by others) over VaproLiqui-Flash embedded in Dow Sheathing in "as new" condition 2 VaproLiqui-Flash + RevealFlashing SA [Self Adhered] Sequencing Exploded View 6 Commercial Window sealant joint + backer rod (by others) RevealShield SA or RevealShield IT field membrane shingled over flashing [sealed w/ Dow 758 for mechanically attached Membranes] In order to maintain continuity of air barrier system, while allowing for proper drainage at sill, a continuous interior window perimeter sealant joint with backer rod is required VaproLiqui-Flash is a liquid applied, vapor permeable, waterproof, air barrier flashing system component for window and door rough openings. VaproLiqui- Flash is designed to work with RevealFlashing SA and VaproShield field membranes as a complete system. RevealShield SA or RevealShield combined with VaproLiqui-Flash + RevealFlashing help facilitate continuous air barriers behind open joint cladding applications over multiple substrate varieties. VaproShield LLC th Ave. N.W. Suite C5 Gig Harbor, WA Toll Free: VaproShield 6/2014
3 Substrate Joints RevealShield SA WRB / AB Field Membrane Sheathing in "as new" condition RevealShield SA Open Joint Field Membrane lap onto thru-wall flashing [by others] min. 3" RevealFlashing SA with VaproLiqui-Flash lap 3" min. onto horiz. surface; seal with Dow 758 Sealant and backer rod where prudent RevealShield SA WRB / AB Field Membrane VaproBatten Rain Screen Batten System
4 Change in Substrate Substrate in "as new" condition Up to 2" Wide Open Joints Note: Use VaproShims with Horiz. Cladding Attachments RevealShield SA Self-Adhered Open Joint Field Membrane Rain Screen VaproBattens System
5 Damage / Defects Dow 758 Sealant tooled or VaproLiqui-Flash top edge of reverse lap RevealFlashing SA or RevealShield SA 6" lap around perimeter of damage
6 Deflection Joint Backer rod [by others] size determined by building envelope consultant RevealShield SA or RevealFlashing SA 2 layers / min. 3" lap past joint RevealShield SA WRB / AB Open Joint Field Membrane Substrate in "as new" condition mortar joints struck flush
7 Expansion or Contraction Joint Substrate in "as new" condition RevealFlashing SA 11.75" with "loop" adhere 3" strip to center of RevealShield SA to back side: adhesive to adhesive RevealShield SA Self-Adhered Open Joint Field Membrane lap onto RevealFlashing SA min. 3" Plan View (NTS)
8 Roof to Wall SlopeShield SA lap onto flashing and/or ice & water shield ice & water shield / flashing with butyl, acrylic, or hybrid adhesive Substrate in "as new" condition RevealShield SA WRB / AB Membrane lap min. 3" in shingle fashion at all seams
9 Substrate Joints Substrate in "as new" condition Note: Use VaproShims with Horiz. Cladding Attachments Up to 2" Wide Open Joints Joints >⅜" require backing RevealShield SA Self-Adhered Open Joint Field Membrane Rain Screen VaproBattens System
10 Wall to Foundation Note: Use VaproShims with Horiz. Cladding Attachments Up to 2" Wide Open Joints RevealShield SA Self-Adhered Open Joint Field Membrane Flashing Membrane RevealFlashing SA or RevealShield SA 3" lap adhere directly to foundation
11 Window or Door Rough Opening SHEATHING IN "AS NEW" CONDITION HEAD FLASHING [BY OTHERS] SET IN DOW 758 OVER VAPROLIQUI-FLASH COMMERCIAL OR FLANGED WINDOW W/ BACKING ROD + SEALANT JOINT OR APPROVED TAPE PER WINDOW MFR. [BY OTHERS] VAPROLIQUI-FLASH CONTINUOUS INSIDE ROUGH OPENING + 1" ON FACE NOTE: INNER WINDOW TO WALL INTERFACE TO PROVIDE CONTINUOUS AIR + WATER TIGHT SEALANT JOINT WITH BACKER ROD TO FACILITATE BACK DAM EFFECT AND AIR BARRIER CONTINUITY REVEALSHIELD SA WRB/AB FIELD MEMBRANE SHINGLED UNDER SILL FLASHING PROPERLY SEQUENCED; APPLIED DIRECTLY TO SHEATHING + FOLDED 2.75" INSIDE OF R.O
12 WRB/AB FIELD MEMBRANE SHINGLED OVER HEAD FLASHING SHEATHING IN "AS NEW" CONDITION RevealShield SA Wall to Window Interface HEAD FLASHING [BY OTHERS] SET IN DOW 758 OVER VAPROLIQUI-FLASH COMMERCIAL WINDOW W/ BACKING ROD + SEALANT JOINT [BY OTHERS] INSIDE ROUGH OPENING + 1" ON FACE RevealFlashing SA PROPERLY SHINGLED; APPLIED DIRECTLY TO SHEATHING + FOLDED 2.75" INSIDE OF R.O
VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS
VAPROLIQUI-FLASH Liquid Applied Waterproof Flashing Material OVERVIEW VaproLiqui-Flash is a liquid applied Waterproof Flashing material for window and door rough opening interfaces. It is designed for
More informationHenry Blueskin VP160 Air Barrier System Installation Manual
Henry Blueskin VP160 Air Barrier System Installation Manual Building Envelope Systems 1 Effective 09/28/2017 US Supersedes all previous versions Table of contents 1. Introduction...3 1.01 Air barrier considerations...3
More informationMULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS
USER S BULLETIN MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS CONTENTS Introduction...1 Use of this Residential Multi-Family User s Bulletin...1 DuPont Multi-Family
More informationSINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS
USER S BULLETIN SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS CONTENTS Introduction...1 Use of This Residential Single Family User s Bulletin...1 DuPont Residential
More informationPella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...
SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood
More informationSenergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board
Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an
More informationPerimeter Relief and Control Joints in Fire-Rated Gypsum Board
Perimeter Relief and Control Joints in Fire-Rated Gypsum Board In multi-family residential construction, involving fire-rated assemblies stress relief in the firerated assemblies is important, but often
More informationWARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationHow do you install yours?
How do you install yours? Darrell Paul Qualistat Building Performance Consultants CSA 440 Just about adding Peel & Stick? 1 Window and door problems Photos / videos Video available for viewing at INSTAGRAM
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08
More informationBLUESKIN VP160 INSTALLATION GUIDELINES
BLUESKIN VP160 INSTALLATION GUIDELINES Effective 09/29/2016 CA Supersedes all previous versions Table of Contents 1. Introduction... 3 1.01 Air Barrier Considerations... 3 1.02 Building Code Standards...
More informationTensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7.
TECHNICAL DATA SHEET Protecto Universal Primer Free Membrane Self-adhered Flashing / Air Barrier / Vapor Retarder Thru-Wall Flashing / Below Grade Waterproofing Membrane with Super Stick technology TECHNICAL
More informationFundamentals of Door Installation START
Fundamentals of Door Installation START Course Description This program provides a general overview of best-practice installation procedures for wood and clad/wood doors, including a discussion on opening
More informationThe Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.
Note: This document has been divided into several sections in order to suit the limitations of the website. The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice
More informationTech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide
Tech Solutions 536.0 WEATHERMATE Straight Flashing Commercial Installation Guide Table of Contents Product Overview.................................................................................3 Benefits
More informationAquaFlash System Installation Guide DS196
AquaFlash System Installation Guide I. General: A. This document provides guidelines for the application and use of the Dryvit AquaFlash System at rough openings for windows, doors and other penetrations,
More informationSenturion TM III Wall System
Senturion TM III Wall System TYPICAL DETAILS 1017666 1. Senturion III Wall System Application (Plan VIew) 2. Senturion III Wall System Application (Isometric View) 3. Aesthetic Groove (Plan VIew) 4. Insulation
More information2006 Building Code Flashing Changes & Challenges. Builder Breakfast and Luncheon Series Presented by:
2006 Building Code Flashing Changes & Challenges Builder Breakfast and Luncheon Series Presented by: 1 Speakers 2006 Building Code Flashing Changes & Challenges Mick Ryan, President, Siding Contractors
More informationFMA_AAMA_WDMA Installation Committee Update FMA Conference May 8, Naples, FL. Jim Katsaros FMA_AAMA_WDMA Installation Committee
FMA_AAMA_WDMA Installation Committee Update FMA Conference May 8, 2013 - Naples, FL Jim Katsaros FMA_AAMA_WDMA Installation Committee Representing the FMA/AAMA/WDMA Installation Coordination Committee:
More informationManaging Rainwater at the Window-Wall Interface
Managing Rainwater at the Window-Wall Interface Prepared by : Silvio Plescia (CMHC) and Michael Lacasse (NRC) ANHWP, Edmonton and Calgary, 23-24 September 2009 CMHC SCHL Introduction The problems you know
More informationNEXT GENERATION HIGH PERFORMANCE WALLS
CONSTRUCTION GUIDE NEXT GENERATION HIGH PERFORMANCE WALLS CLIMATE ZONES 3-5 PART 2: 2X4 Walls with 1" 1.5" Exterior Insulative Sheathing V. Kochkin and J. Wiehagen Home Innovation Research Labs June 2017
More informationEclipse Energy Guard. Product Information & Installation Manual General Installation Requirements
Product Information & Installation Manual 01 Important Notice to Buyers and Users of RoyOMartin wall system These instructions are not intended to cover every installation requirement, application, detail
More informationAir and Vapor Barrier 3015
Air and Vapor Barrier 3015 Technical Data March 2017 Product Description 3M Air and Vapor Barrier 3015 is an air, moisture and water impermeable membrane with an aggressive, high-tack acrylic pressure
More informationSURESILL WATER MANAGEMENT GUIDE
THE SURE LEVEL OF PROTECTION SURESILL WATER MANAGEMENT GUIDE FOR WINDOWS AND DOORS *1 SLOPED SILL PAN ASSEMBLY Cut the channel plate ¼ smaller than the rough opening. Check the fit with end caps before
More informationAvoiding Air Barrier Pitfalls When sub-trade activities are not in sync with air barrier requirements, installation can go poorly.
48 D+D NOVEMBER 2013 Building Envelope Avoiding Air Barrier Pitfalls When sub-trade activities are not in sync with air barrier requirements, installation can go poorly. By Brian H. Neely, AIA, CDT, CBST,
More informationFMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012
FMA / AAMA / WDMA Installation Committee Update Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012 Topics for discussion. Review & Update on FMA/AAMA/WDMA Window & Door
More informationApplication Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS
Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS CHECKLIST PRIOR TO THE INSTALLATION OF BACKSTOP NT - SMOOTH AND TEXTURE Project Conditions Maximum storage
More informationELEVATION FOR DETAIL REFERENCE ONLY
8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08
More informationMagnum Board Section Digicon Information Inc. Page 1
Digicon Information Inc. Page 1 This section includes sheathing for exterior walls for use in a potentially damp or wet exterior cladding environment. This sheathing section forms an exterior flat plane
More informationLP SmartSide Perfection Shingle
Application Instructions Fiber Substrate Lap Siding A A - Lap Siding ON SITE STORAGE Store off the ground well supported, on a flat well-drained surface. (Diagram 1a) Additional support may be required
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05
More informationELEVATION FOR DETAIL REFERENCE ONLY
5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX
More informationGeneral. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings
application instructions STRAND SUBSTRATE 38, 76 AND 190 SERIES PRIMED PANEL SIDING INCLUDING SILVERTECH & SMARTFINISH General At the time of manufacture, siding meets or exceeds the performance standards
More informationDetail Set: Thermax Wall System Masonry
Dow Building Solutions Detail Set: Thermax Wall System Masonry This detail set outlines the masonry guidelines for design using the THERMAX Wall System, focusing around attachment of masonry façades and
More informationFinestone Stucco Ultra Wall System
Finestone Stucco Ultra Wall System Premium impact and puncture resistant, rain screen design cement plaster stucco system with enhanced water management Typical Details BLANK PAGE Finestone Stucco Ultra
More informationfor New Construction Applications
INSTALLATION GUIDE for New Construction Applications Designing and building instructions for ThermalStar LCi are described in the following manual. General installation, fastening details and instructions
More informationDuPont RainVent Batten Installation Guidelines
DuPont RainVent Batten Installation Guidelines Purpose: To improve the ventilation and draining space behind a cladding system or 3-coat stucco system in residential construction. The DuPont RainVent Batten
More informationNCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance
More informationINSTALLATION INSTRUCTIONS
EnergyShield Continuous Wall Insulation INSTALLATION INSTRUCTIONS EnergyShield and EnergyShield CGF CONNECTING FUNCTION WITH FACILITY EnergyShield and EnergyShield CGF Installation Instructions Conditions
More informationDow Corning DefendAir 200: Application Guide
DefendAir 200: Application Guide DefendAir 200: Application Guide DefendAir 200 Application Guide Contents This document is intended to provide installation and field testing guidance for DefendAir 200.
More informationSECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION
SECTION 093000 - SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION PART 1 - GENERAL This specification includes the sheet membrane used as waterproofing, vapor retarder, and crack isolation in conjunction
More informationOSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION
STYRO RAIL 07-0 Expanded Polystyrene Rigid Insulation combined to an Oriented Structural Board INSTALLATION GUIDE * 9 mm [8 ] The OSB.Comfort boards manufactured by Styro Rail are composed of type expanded
More informationRoof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208
Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details D-3 Roof Details M-1 Mechanical - Roof Plan M-2 Mechanical - Details Roof Key Plan
More informationMajrex. System Guidelines For Air Barrier and Vapor Control Installation
Majrex System Guidelines For Air Barrier and Vapor Control Installation fdsa Introduction SIGA Majrex with Hygrobrid technology is a directional, moisture-variable vapor control layer for interior roof,
More informationNOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)
NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS
More informationSTORAGE AND TRANSPORTION
Content 1. General & Notes 2. Substrate Processing 3. Panel Layout 4. Tools 5. Screws 6. Installation instructions 7. Cleaning 8. FAQS 8. MSDS General & Notes In comparison to natural or cast stone, Questone
More informationWeatherproofing & Sealing Systems
Weatherproofing & Sealing Systems Weather Barrier & Waterproofing Residential & Commercial Structures New Construction, Remodeling & Repair Low Slope Roofing Membranes Roofing Underlayments Window & Door
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More informationArmourwall Stucco Systems
Armourwall Stucco Systems Armourwall Stucco Systems Provide THE PAREX ADVANTAGE The Parex tradition of leadership in the building industry began in 1986 with a commitment to growth based on unparalleled
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3435 Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00
More informationIntegrated Air & Water Barrier Systems
Integrated Air & Water Barrier Systems Presented by [ Jeff Presenter s Key, Georgia-Pacific Name ] Wood Products AIA Course: GP-FF-WRBAB Credit Designation: LU HSW Please add relevant logo here Disclaimer:
More informationProper Installation of Insulated Metal Wall Panels
Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also
More information1 Firestone EPDM Roofing Systems
1 Firestone 1. Firestone EPDM Systems To ensure a long-lasting, trouble-free roof today, it is not sufficient to manufacture high quality roofing membranes. Experience learned that roofing membranes need
More informationELEVATION FOR DETAIL REFERENCE ONLY
4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS
More informationSenershield -R / Senershield -VB
Senershield -R / Senershield -VB Air / Water-Resistive Barrier Typical Details 1. Termination at Grade - Sheathing Overlapping Foundation 2. Termination at Grade - Sheathing Overlapping Foundation with
More informationHIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING
HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING ROCCO ROMERO, RA WISS, JANNEY, ELSTNER ASSOCIATES, INC. 960 South Harney St., Seattle, Washington 98108 Phone: 206-622-1441 Fax: 206-622-0701 E-mail: rromero@wje.com
More informationPROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS
SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
More informationLUX Specifications. Section S - Preformed Steel Siding
Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of
More informationInstallation Procedures for the Ultra Air Barrier Wall System
STEEL STUD BACKUP CONSTRUCTION Installation Procedures for the Ultra Air Barrier Wall System Installation Procedures for the Ultra Air Barrier Wall System in Steel Stud Backup 1 System Overview STYROFOAM
More informationInstallation Guidelines for Adhered Concrete Masonry Veneer
Installation Guidelines for Adhered Concrete Masonry Veneer Installation Guidelines for Adhered Concrete Masonry Veneer Page 1 Contents Definitions 3 Abbreviations 3 References 4 Summary Table 5 Workmanship
More informationField Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera
Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera Walter Sebastian BMT Building Enviroment Consultants Ltd., Doktor Neergaards Vej 15, DK-2970 Hoersholm, Denmark
More informationParex USA Stucco Details CSI SECTION
Parex USA Stucco Details CSI SECTION 09 22 00 Note: The design specifications and construction shall comply with all local building codes and standards. Parex USA installation guidelines are for general
More informationColphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate
Colphene BSW Training and Application Guide Colphene BSW Waterproofing Membrane. 1. Prepare substrate Substrate must be structurally sound. Surface must be free of voids, spalled areas, loose aggregate,
More informationSECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 075423 - THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Division 00 Bidding Requirements and other Division
More informationFinestone Stucco System
Typical Details Finestone Stucco System Cement Plaster Stucco 1. Typical Finestone Stucco System with Steel Framing 2. Typical Finestone Stucco System with Wood Framing 3. Typical Finestone Stucco System
More informationRainscreen Gaps in Exterior Walls
PHRC Webinar Series Tuesday, September 13 @ 1pm Rainscreen Gaps in Exterior Walls Brian Wolfgang Housing Systems Specialist Pennsylvania Housing Research Center 219 Sackett Building University Park, PA
More informationThe Original. The Innovator.
50368 York MoistureControl Rev5:50368 YorkMoistureControl 9/11/08 2:33 PM Page 1 The Original. The Innovator. 50368 York MoistureControl Rev5:50368 YorkMoistureControl 9/11/08 2:33 PM Page 2 Through-Wall
More informationDRY SEAL INSTALLATION GUIDE
DRY SEAL INSTALLATION GUIDE Effective September 2015 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Handling and Maintenance of Omega-Lite Panels 1 System Limitations and Pre-Installation
More informationSLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu
INSTALLATION INSTRUCTIONS Note: The following installation instructions are based off of ASTM E 1643 (Standard Practice for Installation of Water Vapor Retarders Used in Contact with Earth or Granular
More informationE. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.
DELTA -DRAIN Section 07 10 00 Dampproofing and Waterproofing PART 1 GENERAL 1.1 SECTION INCLUDES A. Below grade drainage sheets. B. Plaza deck and planter drainage sheets. 1.2 RELATED SECTIONS A. Section
More informationREPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3914 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2045 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 07 00
More informationAcceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.
SECTION 093000 - SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL This specification includes the sheet membrane used as waterproofing and vapor retarder, in conjunction with tile and dimension stone installations.
More informationREPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1474 Reissued 10/2016 This report is subject to renewal 10/2018. DIVISION: 06 00
More informationA. Source Limitations: Obtain each type of building insulation through one source.
SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationENGINEERING EVALUATION
April 2017 To Whom It May Concern, Attached is the Engineering Evaluation Engineering Extensions based on 4 NFA Tests repared for Rmax Operating Refer to pages 4 and 12 to find multiple VaproShield WRB/Air
More information1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards
SECTION 07185 TRAFFIC MEMBRANE PART 1 GENERAL 1.1 SECTION INCLUDES A. Traffic membrane, consisting of welded seam PVC waterproofing, over f following surfaces: 1. Decks, balconies, and sun porches 2. Walkways,
More informationSECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***
***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Clear copper and preweathered copper
More informationAdvanced technologies for enhancing the building envelope. 3M Building and Construction Market
Advanced technologies for enhancing the building envelope 3M Building and Construction Market Controlling air is crucial for the health & energy efficiency of buildings Ensuring you have the right air
More informationCommercial Air Barrier Systems
Building Envelope Systems Roofing Air Barrier Waterproofing Ask us today about other Henry solutions that help manage the flow of water, air, vapor and energy. Commercial Air Barrier Systems The industry
More informationWater Penetration Resistance - Design and Detailing
Technical Notes on Brick Construction 7 114 Commerce Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Water Penetration Resistance - Design and Detailing Abstract: Proper design, detailing
More informationRS32 Multi-Section Skylight System under/over seam clip double diverter
INSTALLATION INSTRUCTIONS RS32-x RS32 Multi-Section Skylight System under/over seam clip double diverter www.rnssales.com sales@rnssales.com 805.375.3980 Fax 805.375.3981 SKYLIGHT ACRYLIC skyline series
More informationMCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON
ADDENDUM NUMBER FROM: MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 0 / 533 WEST MAIN STREET TUPELO, MS 3880 / 3880 FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON PHONE: -8-00 PROJECT: ACADEMIC STUDENT
More informationGeneral Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.
General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions. Surface Preparation: Surface to be coated should be clean, dry and structurally sound.
More informationBuilding Envelope Moisture Drainage & Ventilation Products from Keene Building Products
Building Envelope Moisture Drainage & Ventilation Products from Keene Building Products NEW Products Driwall Rainscreen CAV-AIR-ATOR KeeneStone Cut KeedeLath Driwall Weep Screed Driwall Membrane (Flashing)
More informationRE: Exterior Wall Analysis Use of Gypsum Sheathing Over Dow Thermax Insulation in NFPA 285 Complying Wall Assemblies No. 1JJB05306.
December 8, 2017 Dow Building Solutions The Dow Chemical Company 1605 Joseph Drive Midland, MI 48642 RE: Exterior Wall Analysis Use of Gypsum Sheathing Over Dow Thermax Insulation in NFPA 285 Complying
More informationSECTION MANUFACTURED ROOF EXPANSION JOINTS
SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationTHERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240
STUC-O-FLEX THERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary to install
More informationMID-RISE DESIGN & CONSTRUCTION
TECHNICAL BULLETIN No.38-021616 Rev072116 MID-RISE DESIGN & CONSTRUCTION Logix effective R-values range from R-24 to R-28+ Insulated concrete forms (ICF) are becoming a main stream choice for the construction
More informationBEP Blue Barrier Installation and Application Guide
BEP Blue Barrier Installation and Application Guide BEP Blue Barrier is a system of seamless fluid applied products designed to protect the building envelope. Approved assemblies and applications listed
More informationSynthetic Stucco Without Failures To avoid a lawsuit, build a drainable assembly
BEST PRACTICES STUCCO Synthetic Stucco Without Failures To avoid a lawsuit, build a drainable assembly BY MARK PARLEE Photos: Mark Parlee I started out 38 years ago as a framing and siding contractor in
More informationPERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960
STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary
More informationWALL PROTECTION VIDEOS PROJECT GALLERY INSTALL GUIDES TECH SUPPORT. BenjaminObdyke.com (800)
WALL PROTECTION Wall Protection Solutions from Benjamin Obdyke Water will find a way in. Most building scientists not only believe this fact, but also agree that the best way to avoid issues caused by
More informationInsulated Panels North America. KarrierPanel Universal Barrier Wall Solution
Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall
More informationINSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings
FINEGAN INSPECTION SERVICES, INC. 27 Laurelwood Drive Milford Ohio, 45150 513 683-0733 RESIDENCE LOCATION INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings OVERVIEW The report
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00
More informationExterior Building Materials & Detailing
Exterior Building Materials & Detailing Marquam George Marquam George LLC Juneau, Alaska marquamgeorge@gmail.com Barriers to? V.1950 Air only Vapor only Water only Air & Water 1 V.1990 V.2005 Detailing
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION
ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)
More informationExterior Stucco and Siding Installation
Exterior Stucco and Siding Installation CITY OF NEWARK, CALIFORNIA BUILDING INSPECTION DIVISION 37101 Newark Boulevard, Newark, CA 94560-3796 510-578-4261 Fax 510-578-4307 e-mail: building.inspection@newark.org
More information